Plan Review Details - Permit 04120942
Plan Review Stops For Permit 04120942
Review Stop B BUILDING (STRUCTURAL)
Rev No 16 Status P Date 2008-06-05 Cont ID  
Sent By jwitmer Date 2008-06-05 Time 16:52 Rev Time 0.55
Received By jwitmer Date 2008-06-05 Time 16:52 Sent To PC
Notes
2008-06-05 16:53:25REVISION SITE WALL

Review Stop B BUILDING (STRUCTURAL)
Rev No 15 Status P Date 2008-03-10 Cont ID  
Sent By jwitmer Date 2008-03-10 Time 16:48 Rev Time 3.33
Received By jwitmer Date 2008-03-10 Time 16:48 Sent To  
Notes
2008-03-10 16:49:54PRODUCT APPROVAL RESTAMPS,
 LETTERS FROM DESIGN PROFESSIONAL AND REVISION TO POST
 DETAIL

Review Stop B BUILDING (STRUCTURAL)
Rev No 14 Status P Date 2007-11-08 Cont ID  
Sent By jwitmer Date 2007-11-08 Time 07:45 Rev Time 3.33
Received By jwitmer Date 2007-11-08 Time 07:45 Sent To  
Notes
2007-11-08 07:46:27RESTAMP PLANS

Review Stop B BUILDING (STRUCTURAL)
Rev No 13 Status P Date 2006-07-20 Cont ID  
Sent By jwitmer Date 2006-07-20 Time 07:48 Rev Time 0.55
Received By jwitmer Date 2006-07-20 Time 07:48 Sent To B
Notes
2006-07-20 00:00:00STAIR SHOP DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 12 Status P Date 2006-07-13 Cont ID  
Sent By jwitmer Date 2006-07-13 Time 07:21 Rev Time 0.55
Received By jwitmer Date 2006-07-13 Time 07:46 Sent To PC
Notes
2006-07-13 00:00:00REVISION FENCE

Review Stop B BUILDING (STRUCTURAL)
Rev No 11 Status F Date 2006-06-15 Cont ID  
Sent By jwitmer Date 2006-06-15 Time 07:58 Rev Time 0.77
Received By jwitmer Date 2006-06-15 Time 07:58 Sent To PC
Notes
2006-06-15 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04120942
 ADD: 2010 PONCE DE LEON AV
 CONT: TAYCON
 TEL: (561)262-2113
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: STAIR SHOP DRAWINGS
 ACTION: DENIED
  
 THE TOP SET OF WINDERS FAILED:
 1007.8.1 WINDERS SHALL HAVE A MINIMUM
 TREAD DEPTH OF 6 INCHES (152 MM)
 AT THE NARROW EDGE AND SHALL HAVE A
 MINIMUM TREAD DEPTH OF 11 INCHES (279
 MM) AT A POINT 12 INCHES (305 MM) FROM
 THE NARROW EDGE.WINDERS SHALL BE
 PERMITTED TO BE USED AS A COMPONENT IN
 THE MEANS OF EGRESS WITHIN A
 DWELLING UNIT.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 10 Status P Date 2006-04-03 Cont ID  
Sent By jwitmer Date 2006-04-03 Time 09:07 Rev Time 1.55
Received By jwitmer Date 2006-04-03 Time 09:07 Sent To PC
Notes
2006-04-03 00:00:00STRUCTURAL REVISIONS, CREATING LOFT IN
 END UNIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status F Date 2006-04-03 Cont ID  
Sent By jwitmer Date 2006-07-13 Time 13:13 Rev Time 1.55
Received By jwitmer Date 2006-04-03 Time 08:37 Sent To PC
Notes
2006-04-03 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04120942/04120945
 ADD: 2010 PONCE DE LEON
 BLDG# 1
 BLDG# 2
 CONT: TAYCON
 TEL: (561)282-7310
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: REVISION
 ACTION: DENIED
  
  
 NO ROOFING PERMIT APPLIED FOR, FOR
 EITHER BUILDING.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2006-02-06 Cont ID  
Sent By jwitmer Date 2006-02-06 Time 12:24 Rev Time 1.22
Received By jwitmer Date 2006-02-06 Time 12:02 Sent To PC
Notes
2006-02-06 00:00:00REV TO TENANT SEPERATION WALL 2HR CONDO

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2005-12-19 Cont ID  
Sent By jwitmer Date 2005-12-19 Time 07:12 Rev Time 0.33
Received By jwitmer Date 2005-12-19 Time 07:12 Sent To PC
Notes
2005-12-19 00:00:00REV 9-26-05# 2

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2005-11-10 Cont ID  
Sent By jwitmer Date 2005-11-10 Time 16:22 Rev Time 0.55
Received By jwitmer Date 2005-11-10 Time 16:22 Sent To PC
Notes
2005-11-10 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04120942
 ADD: 2010 PONCE DE LEON
 CONT: TAYCON COSTRUCTION
 TEL: (561)282-7310
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVISIONS:
 ACTION: DENIED
  
 THE REVISION LEGOND IS NOT FILLED OUT ON
 S-1,S-2, S-3,S-4 & S-5 HAVE DATES BUT DO
 NOT IDENTIFY WHICH REVISIONS ARE
 ASSOCIATED WITH THE INDICATED DATES.
 FL BLD CODE 104.2.1.2*
 ADDITIONAL INFORMATION REQUIRED.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-11-10 Cont ID  
Sent By jwitmer Date 2005-11-10 Time 09:46 Rev Time 0.77
Received By jwitmer Date 2005-11-10 Time 09:46 Sent To Z
Notes
2005-11-10 00:00:00#5 REVISION TO SITE WALL

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-09-27 Cont ID  
Sent By jwitmer Date 2005-09-27 Time 08:50 Rev Time 4.44
Received By jwitmer Date 2005-09-22 Time 15:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-08-13 Cont ID  
Sent By jwitmer Date 2005-08-13 Time 16:25 Rev Time 0.00
Received By jwitmer Date 2005-08-13 Time 16:25 Sent To  
Notes
2005-08-13 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04120942
 ADD: 2010 PONCE DE LEON
 CONT: TAYCON
 TEL: (561762-0606
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 3RD REVIEW
 ACTION: DENIED
  
 PRODUCT APPROVALS
 1) THE FL COVERSHEET FOR PGT FIXED
 WINDOWS WAS SUBMITTED BUT NOT THE NOA.
  
 2) THE SAAME HOLDS TRUE WITH THE PGT
 MULLIONS ONLY THE COVERSHEETWHILE THE
 REPORT INDICATES VAARIOUS NOA'S ARE
 COVERED WITHIN THIS REPORT.
  
 3) UNDER THE GARAGE DOOR REPORT
 HIGHLIGHT OR INDICATE WHICH DOOR OR
 SERIES YOU ENTENDTO USE?
  
 4) STEEL ROOF PANELS ALSO INDICATE WHICH
 SYSTEM INSULATED OR NOT? IF USING THE
 NONINSULATED SYSTEM THE SYSTEM
 LIMITATION OF A -60 MAXIMUM DESIGN
 PRESSURE. YOUR ENGINEER CALCULATED AN
 END ZONE PRESSURE OF -54.1 BUT USING THE
 TRIBUTARY AREA OF 55 SQ FT. HE NOTES THE
 END ZONE IS 3'. 3'X3'=9 SQ FT. AGAIN THE
  
 TABLES IN 1606.2B INDICATE A -68.1 WHICH
 WILL REQUIRE ENHANCED FASTENING BY YOUR
 ENGINEER ONLY FOR ZONE 3.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-06-08 Cont ID  
Sent By jwitmer Date 2005-06-08 Time 08:14 Rev Time 8.80
Received By jwitmer Date 2005-06-08 Time 08:14 Sent To  
Notes
2005-06-08 00:00:00BUILDING PLAN REVIEW
 PERMIT:04120942
 ADD: 2010 PONCE DE LEON AV
 CONT: TAYCON CONSTRUCTION
 TEL: (561)718-3045
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
  
  
  
 2ND REVIEW
 ACTION: DENIED
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 SHEET A1.1.0 BUILDING DATA, MISSING
 INFORMATION FROM TABLE 500, BUILDING
 TYPE VI, IS PROVIDED, UNPROTECTED IS
 PROVIDED, BUT THE DECLARATION FOR
 INCREASE IN HEIGHT, FOOTNOTE "H" IS
 MISSING, TO ACCOMADATE THE STORY
 INCREASE (3 STORY).
  
 2A) COMMENT # 1 FROM THE PREVIOUS REVIEW
 DEALS WITH THE REMOVAL OF THE WORDING
 "TOWNHOUSE OR TOWNHOMES", THIS
 TERMINOLOGY IS INDICATED ON THE SOILS
 REPORT.
  
 2B) SOILS REPORT INDICATES THAT THEY ARE
 FOR 200-212 SW 9TH AVENUE FT LAUDERDALE
  
 2C) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 WHERE THE BEARING CAPACITY OF THE SOIL
 IS NOT DEFINITLY KNOWN OR IS IN QUESTION
 THE BUILDING OFFICIAL MAY REQUIRE EXPLOR
 ATIONS, TEST OR OTHER ADEQUATE PROOF AS
 TO THE PERMISSIBLE SAFE BEARING
 CAPACITY. REQUIRED TEST AND RECOMMENDA-
 TIONS SUBMITTED TO VERIFY BEARING CAPA-
 CITY SHALL BE CERTIFIED BY A GEOTECH-
 NICALREPORT FROM A DESIGN PROFESSIONAL
 PROPERLY LICENSED IN THE STATE OF
 FLORIDA.
  
 2D) SOILS REPORTS ARE TO BE ORIGINALS
 WITH RAISED SEAL & SIGNATURES. PLANS,
 SPECIFICATIONS,REPORTS OR OTHER
 DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 3) COMMENT # 4 FROM THE PREVIOUS REVIEW,
 FL BLD CODE CHAP 13 ENERGY EFFICENCY
 PROVIDE ENERGY CALS, THE GENERAL PROJECT
 DATA REPORT IS A COPY WITH THE DESIGN
 PROFESSIONALS COPIED SIGNATURE.
 PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 4) DEALS WITH THE COMMENT# 12 FROM THE
 PREVIOUS REVIEW, SEE 411.2.6 FOR
 OCCUPANCY SEPERATION REQUIRED FROM THE
 HABITABLE AREAS TO THE GARAGE (R2), THE
 DOOR SCHEDULE HAS WHITE OUT ON THE
 SCHEDULE FOR THESE DOORS, THE SECOND
 ISSUE IS FOR THE (1) HR RATED WALL PLANS
 INDICATE A "C" LABEL DOOR, TABLE 705.1.2
 INDICATES OPENING PROTECTIVES IN MINUTES
 AND HOURS, PLEASE CORRECT.
  
 5) COMMENT# 15 FROM THE PREVIOUS REVIEW,
 S-6 TRUSS ANCHORS REQUIRE LOAD
 REDUCTIONS, 1609.4.3, DETAIL "A",GOOD
 FOR 11,150 NOT 12,340 SEE 2005 USP
 CATALOG.
  
 6) COMMENT# 17 FROM THE PREVIOUS REVIEW,
 S-7 ROOF UPLIFT PRESSURES ARE STILL LOW
 USE TABLE 1606.2B , ROOF ANGLES > 10-30
 DEGREES, WITH MULTIPLIER FROM TABLE
 1606.2D "B" = 1.05 FOR 33.83' MEAN ROOF
 HEIGHT.
  
 7) COMMENT# 18 FROM THE PREVIOUS REVIEW,
 EITHER THE ARCH OR STRUC SHEETS (ELE)
 INDICATE THE POS & NEG PRESSURES FOR
 OPENINGS, INCLUDE ENDZONES AND INTERIOR
 ZONES, AND MULTIPLIER FOR 33.83 MEAN
 ROOF HEIGHT.
  
 8)COMMENT# 19 FROM THE PREVIOUS REVIEW
 PRODUCT APPROVALS SUBMITTED WITH PERMIT
 APPLICATION AFTER OCTOBER 1, 2003 ARE
 REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 9)COMMENT# 20 FROM THE PREVIOUS REVIEW,
 FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) EXTERIOR DOORS THE TESTING REPORT
 FOR THERMA-TRU DOORS WILL REQUIRE
 LOCAL PRODUCT APPROVAL, THE
 MANUFACTURER IS TO FILL OUT THIS
  
 FORM.
 B) TRUSS ANCHORS: PROVIDE THE FLORIDA
 COVERSHEET FOR, FL 821.8, FL 815.11
 & FL 2620.6.
 C) ROOF ASSEMBLIES:PRODUCT SUBMITTED
 ENGLERT INC. LOW PRESSURE FOR ZONE# 3.
 DEPENDING ON WHICH APPLICATION WHICH
 NONE ARE MARKED AS TO WHICH WILL BE
 USED, MAY HAVE PRESSURE LIMITATION OF
 -52.5.
 THE SECOND ISSUE IS THE DESIGN
 PROFESSIONAL SPECIFIES A DIFFERENT
 MANUFACTURER ON THE ELEVATIONS.
  
 10)COMMENT# 23 FROM THE PEVIOUS REVIEW,
 BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 11) NEW COMMENT, DEALS WITH THE POOL;
  
 11A) THE LOCATION OF THE POOL VS THE
 LOCATION AND CHANGE IN ELEVATION FOR THE
  
 BALCONY FOOTINGS. SEE1803.1.3
 EXCAVATION FOR ANY PURPOSE SHALL NOT
 EXTEND WITHIN 1 FT OF THE ANGLE OF
 REPOSE OR NARURAL SLOPE OF THE SOIL
 UNDER ANY FOOTING OR FOUNDATION, UNLESS
 SUCH FOOTING OR FOUNDATION IS FIRST
 PROPERLY UNDERPINNED OR PROTECTED
 AGAINST SETTLEMENT.
  
 11B) ALSO DEALS WITH THE LOCATION OF THE
  
 POOL VS. LIVING ROOM WINDOWS. 424.17.1.9
 (1) POOLS AND SAFETY ALARMS.
  
 NOTE :REVERSED
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-01-13 Cont ID  
Sent By jwitmer Date 2005-01-13 Time 10:15 Rev Time 8.50
Received By jwitmer Date 2005-01-13 Time 10:14 Sent To  
Notes
2005-01-13 00:00:00BUILDING PLAN REVIEW
 PERMIT:04120942
 ADD: 2010 PONCE DE LEON AV
 CONT: TAYCON CONSTRUCTION
 TEL: (561)718-3045
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL
 LETTER
 LISTING THE ORIGINAL REVIEW COMMENT
 NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR
 SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 1) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED, THERE
 SEEMS TO BE A DISCREPANCY IN THE
 PROJECT
 BETWEEN THE OCCUPANCY CLASSIFICATION.
 PERMIT APPLICATIONS INDICATE 8-UNIT
 TOWNHOMES, WHEREAS IT WAS INPUT INTO
 THE
  
 COMPUTER AS CONDOMINIUM.
 A1.1.0 PROJECT DATA INDICATES A-2
 MULTIFAMILY/ CONDOMINIUM
 A2.1.1 CONSTRUCTION NOTES: GROUP R-3,
 8 SINGLE FAMILY DWELLING TOWNHOMES.
 PLEASE MAKE CORRECTIONS, IF THIS IS TO
 BE CONDOMINIUM PLEASE REMOVE ALL
 TERMINOLOGY TOWNHOMES OR TOWNHOUSES.
  
 THIS REVIEW WILL BE COMPLETED WITH THE
 OCCUPANCY REQUIREMENTS FOR THE GROUP
 R-2
 APARTMENTS & CONDOMINIUM REQUIREMENTS.
 TYPE V UNPROTECTED / SPRINKLERED.
  
 2)THE PROPOSED BUILDING STRUCTURE
 TRANSGRESSES LEGAL BOUNDARY LINES
 BETWEEN THE LOTS WHICH COMBINE TO FORM
 'THE SITE'.A 'UNITY OF TITLE' SHALL
 BE
 RECORDED AT THE COUNTY COURTHOUSE.
 SUBMIT A COPY OF THE RECORDED 'UNITY OF
 OF TITLE' DOCUMENT SO THAT FBC TABLE
 600
 BOUNDARY LINE REQUIREMENTS MAY BE
 DEEMED
 NOT APPLICABLE.
  
 3)FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 WHERE THE BEARING CAPACITY OF THE SOIL
 IS NOT DEFINITLY KNOWN OR IS IN
 QUESTION
 THE BUILDING OFFICIAL MAY REQUIRE
 EXPLOR
 ATIONS, TEST OR OTHER ADEQUATE PROOF AS
 TO THE PERMISSIBLE SAFE BEARING
 CAPACITY. REQUIRED TEST AND RECOMMENDA-
 TIONS SUBMITTED TO VERIFY BEARING CAPA-
 CITY SHALL BE CERTIFIED BY A GEOTECH-
 NICALREPORT FROM A DESIGN PROFESSIONAL
 PROPERLY LICENSED IN THE STATE OF
 FLORIDA.
  
 4)FL BLD CODE CHAP 13 ENERGY EFFICENCY
 PROVIDE ENERGY CALS/ W MANUAL "J"
 CORRECT FORMS (3) NUMBER OF UNITS
  
 5) SHEET A1.1.0 INDICATES THAT THE BACK
 OF THE BUILDINGS ARE LOCATED 5'-8" AWAY
 FROM THE PROPERTY LINE.
 5A)TABLE 600 REQUIRES THE EXTERIOR
 WALLS
 TO BE A 2HR RATING WHEN OVER 3' FROM
 THE
 PROPERTY LINE TO 10'-0" AWAY. HAVE THE
 BLOCK MANUFACTURER PROVIDE THE
 EQUIVALENT THICKNESS FOR THEBLOCK,
 SEE
 709.3.1.
 5B) SINCE THE REAR WALLS ARE LESS THAN
 15'-0" FROM THE PROPERTY LINE(ALL
 FLOORS) ANDA R-2 OCCUPANCY,
 705.1.1.2
 SHALL REQUIRE OPENING PROTECTIVES FOR
 THE REAR OPENINGS.
  
 6) THE SAME SITUATION OCCURS ON THE
 FRONT OF THESE BUILDINGS. TABLE 600 SEE
 EXTERIOR WALLS BEARING OR NONBEARING
 REQUIRES 2HR RATED WALLS AND ASSUMED
 PROPERTY LINES.
 6A) PROVIDE BLOCK EQUIVALENT THICKNESS
 FOR A 2HR RATED BLOCK 709.3.1.
 6B) LESS THAN 15' FROM AND ASSUMED
 PROPERTY LINE REQUIRING OPENING
 PROTECTIVES.
 6C) TABLE 600 ISSUES FRONT OF BUILDING
 LOCATED 12.66' FROM ASSUMED PROPERTY
 LINE ALLOWS 20% OPENINGS PER FLOOR. THE
  
 FIRST FLOOR OVER THE 20% ALLOWABLE
 OPENINGS.
  
 7) FBC* 105.3RESIDENT INSPECTOR.
 SUBMIT INSPECTOR RESUME' AND LICENSE
 DOCUMENTS TO HAROLD PISKURA, DIRECTOR
 OF
 THE RESIDENT INSPECTOR PROGRAM.A
 RESIDENT INSPECTOR PROGRAM IS REQUIRED,
 ON THIS PROJECT, DUE TO ONE OR MORE OF
 THE FOLLOWING:
 - BUILDINGS/ADDITIONS OF TYPE I OR II
 CONSTRUCTION
 - ANY MAJOR STRUCTURAL ALTERATIONS
 - STRUCTURES IN WHICH THE CONCRETE
 DESIGN IS BASED ON COMPRESSIVE
 STRENGTH (F'C) IN EXCESS OF 3000 PSI
 - PILE DRIVING
 - BUILDINGS OVER 20,000 SQFT IN AREA
 - BUILDINGS OVER 2 STORIES IN HEIGHT
 - BUILDING/STRUCTURES OF UNUSUAL
 DESIGN
 OR METHODS OF CONSTRUCTION
  
 8) NOTE SITE AMENITIES PERMIT WILL BE
 REQUIRED FOR SITE WALL, GATES, ETC...
  
 9) THE FIRST FLOOR OF ALL CONDOMINIMUM
 HAVING A RESTROOM OR BATHROOM,
 11-4.22.2(1) SHALL HAVE AT LEAST ONE
 RESTROOM OR
 BATHROOM WITH A CLEAR OPENING OF 29".
 SEE DIFINITION OF CLEAR OPENING,
 MINIMUM
 WIDTH OF 32".
  
 10) SHEET A2.1.1 & SHEET A2.1.2 BOTH
 BUILDINGS SHALL MEET THE MAXIMUM STAIR
 HEIGHT REQUIREMENT OF 7", MINIMUM
 HEIGHT
 OF 4" SEE 1007.3.1.
  
 11) STAIR CONSTRUCTION SEE A6.1.0.
 1007.1.1 INTERIOR STAIRWAYS SHALL BE
 CONSTRUCTED OF NONCOMBUSTIBLE MATERIALS
 THROUGHOUT IN THE FOLLOWING BUILDINGS:
 (3)ALL BUILDINGS 3 STORIES OR MORE IN
 HEIGHT.
  
 12) SHEET A2.1.1, A2.1.2 AND A7.3.0
 DOOR SCHEDULEPLANS DO NOT INDICATE
 THE OCCUPANCY SEPERATION REQUIRED FOR
 THE WALL NOR DOOR, SEE411.2.6 AND TABLE
  
 704.1.
  
 13) SHEET A2.3.1 & A2.3.2 PLANS DOESN'T
  
 SHOW WHERE THE ATTIC ACCESS? FL BLD
 CODE 2309.6 ATTIC ACCESS, PRO- VIDE
 ATTIC ACCESS 20"X36".
  
 14) VARIOUS SHEETS THROUGHOUT THE PLAN
 INDICATE CODE SECTIONS REGAURDING
 ROOFING,1518.9, 1518.2.1,1518.4,&
 1517.5.2. THESE CODE SECTIONS ARE FOR
 HIGH WIND ZONES, DADE & BROWARD
 COUNTIES
 AND UNENFORCEABLE.
  
 15) S-5 DETAIL # 1, SEE 2005 USP
 CATALOG
 FOR LISTING 2005 HIGH VALUE. SAME
 DETAIL
 SHEET S-6 DETAIL# 2.
 1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD
 LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS
 OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE
 EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE
 LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS
 SPE
 CIFIED IN THE MATERIALS SECTIONS OF
 THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
  
 16)S-6 ROOF FRAMING PLAN NOTE # 2,
 CORRECT NOT IN HIGH VELOCITY ZONE.
  
 17) S-7 ROOF UPLIFT PRESSURES ARE LOW
 WHEN FIGURING A "C" ZONE WITH HEIGH
 FACTORS TABLE 1606.2D. REVISE
  
 18)EITHER ON ARCH. OR STRUCTURAL SHEETS
 (ELE) INDICATE POS & NEG WINDOW & DOOR
 PRESSURES. THE A7.40 ALLOWABLE WIND
 LOAD
 IS GIVEN BUT NOT THE ACTUAL WIND LOADS,
 NOR INDICATION IF LOCATION IS IN A END
 ZONE SEE 1606.2D FOR MULTIPLIERS FOR
 INDICATED "C" ZONE AND HEIGHT FACTORS.
  
 19) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 20)FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A)WINDOWS OPERATABLE & FIXED
 B) GLASS BLOCK
 C) MULLIONS
 D) EXTERIOR SOLID DOORS
 E) EXTERIOR GLASS/ SLIDING DOORS
 F) OVERHEAD GARAGE DOORS
 G) STORM SHUTTERS IF GLAZING NOT
 TESTED
 FOR LARGE MISSLE IMPACT
 H) SIDING
 I) TRUSS ANCHORS
 J) ROOFING ASSEMBLIES
  
 21)1707.4.5.1 MULLIONS OCCURRING BETWEEN
 INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
 22)1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
  
 23) BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2005-09-22 Cont ID  
Sent By dpalmer Date 2005-09-22 Time 17:49 Rev Time 0.00
Received By dpalmer Date 2005-09-22 Time 17:49 Sent To  
Notes
2005-09-22 00:00:00ELECTRICAL PLANS STAMPED.
  
  
  
  
 ** HIGH LIGHTED PLANS**
  
 NO AFTER DUSK SWIMMING PERMITTED

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2005-09-11 Cont ID  
Sent By dpalmer Date 2005-09-11 Time 10:39 Rev Time 1.00
Received By dpalmer Date 2005-09-11 Time 10:15 Sent To  
Notes
2005-09-11 00:00:00********** UNSAT ****************
  
  
 PLEASE SEE THE FOLLOWING COMMENTS AS
 THIS PROJECT IS PLACED ON HOLD FOR
 ELECTRICAL.
  
 1)NOTE: PLEASE SEE PERMIT APPLICATIONS
 FOR EACH BLDG DID NOT COME BACK IN WITH
 PACKAGE. CALLED AND LEFT MESSAGE OR MR.
 TOM BROWNE.
 PLEASE ALSO SEE A RESUB COVER SHEET WAS
 ONLY FILLED OUT AND PLANS WERE ONLY
 RESUBBED UNDER 04120942 AND DID NOT
 INLCUDE 04120945.
 RESUB FEE FOR 04120945 WAS ADDED.
  
 2)NOTE: PLEASE SEE ALL PREVIOUS REVIEWS
 WHICH REQUESTED ALL OLD/VOIDED SHEETS TO
 BE COMPLETELY REMOVED FROM SETS AND ONLY
 INSERT NEW REVISED SHEETS INTO COMPLETE
 SETS FOR REVIEW AND STAMPING.
 ONLY ONE SET OF OLD/VOIDED SHEET ARE
 SUBMITTED SEPARATELYAND NOT IN THE
 SAME ROLLS.
  
 3)NOTE: PLEASE SEE SHEET A1.2.0 IS STILL
 A SEALED PHOTO-COPY OF A SIGNED PLAN.
 PLANS MAY BE RETAINED FOR POSSIBLE
 REVIEW BY STATE LEGAL COUNSEL TO THE
 BOARD OF ARCHITECTS AS THIS HAS BEEN
 REQUESTED ON PREVIOUS REVIEWS TO
 CORRECT AND NO CHANGES HAVE BEEN MADE.
 PLEASE SEE FS 481.221.
  
  
 4) NOTE:PLEASE SEE NO FURTHER
 ELECTRICAL CORRECTIONS ARE NEEDED.
 PHOTO-METRICS WILL BE REMOVED AS PART OF
 THIS PERMIT AS PLANS NOW MENTIONS THERE
 WILL BE NO NIGHT-TIME SWIMMING.
  
 PLEASE ADDRESS THE ABOVE COMMENTS BY
 CALLING THIS OFFICE TO GO OVER BEFORE
 PLANS ARE SENT OUT ONCE AGAIN.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2005-07-12 Cont ID  
Sent By dpalmer Date 2005-07-12 Time 21:26 Rev Time 1.00
Received By dpalmer Date 2005-07-12 Time 20:41 Sent To  
Notes
2005-07-12 00:00:00IN ELECTRICAL FOR REVIEW.
 **********UNSAT ***********
  
 PLEASE SEE NOTES BELOW>
  
 1)NOTE: PLEASE SEE NOTE #14 FROM FIRST
 TWO REVIEWS. PLEASE SEE RESPONSE LTR
 MENTIONS ARCH TO ADDRESS.
 PLEASE SEE PHOTOMETRICS DO NOT CONTAIN
 ANY STAMP FROM PALM BEACH COUNTY HEALTH
 DEPARTMENT FOR NIGHT-TIME SWIMMING.
  
  
 2)NOTE: PLEASE SEE SHEET E-3 WHICH
 CONTAINS 3RD FLOOR AND PANEL SCHEDULES
 FOR PANELS "A" AND "B". PLEASE SEE PANEL
 SCHEDULES FOR "A" AND "B" WERE MOVED TO
 E-FOUR, HOWEVER THESE PANEL SCHEDULES
 WHICH WERE NOT REVISED FOR CORRECTIONS
 ARE STILL SHOWN ON E-3. ???
 PLEASE ALSO SEE ONE SET OF PLANS, SHEET
 E-3 IS A PHOTOCOPY OF SIGNED,DATED AND
 SEALED PLANS.
 FS 471.025
  
  
 ***NOTE ONLY****
 PLEASE ALSO SEE A.1.2.0 OF SAME SET.
 THIS IS STILL A SEALED PHOTOOPY. THIS
 WAS CORRECTED ON TWO SETS, BUT NOT
 THIRD.? SEE BLDG REVIEW COMMENTS FOR
 A-SHEET.
  
 PLEASE REMOVE SAID SHEETS WHICH NEED TO
 BE CORRECTED. (E-3) AND INSERT NEW
 REVISED SHEETS INTO COMPLETE SETS FOR
 REVIEW AND STAMPING.
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-06-14 Cont ID  
Sent By dpalmer Date 2005-06-14 Time 17:34 Rev Time 4.00
Received By dpalmer Date 2005-06-14 Time 15:30 Sent To  
Notes
2005-06-14 00:00:00************UNSAT 2ND REVIEW *******
  
 ***************************************
 PLEASE SEE SOME NOTES FROM PREVIOUS
 REVIEW STILL NEED TO BE ADDRESSED.
 PLEASE SEE SOME NOTES ARE NOW N/A DUE TO
 CHANGES IN DESIGN.
 PLEASE SEE MANY NEW NOTES DUE TO CHANGES
 ON PLANS.
 PLEASE SEE THE FIRST SET OF NOTES ARE
 TAKEN DIRECTLY FROM PREVIOUS REVIEW.
  
 1)NOTE: UNABLE TO VERIFY: PLEASE SEE
 PERMIT APPLICATION COULD NOT BE LOCATED
 IN PLANS/PRODUCT APPROVALS/ PACKAGE
 RESUBMITTED.
 PLEASE SEE BLDG REVIEW COMMENTS
 PERTAINING TO THE NOTING OF "TOWNHOUSES"
 ETC.
  
 2)NOTE: NOTE #2 N/A SEE NEW NOTES.
  
 3)NOTE: NOTE #3 N/A SEE NEW NOTES.
  
 4)NOTE: NOTE #4 N/A SEE NEW NOTES.
  
 5)NOTE: NOTE #5 N/A SEE NEW NOTES.
  
 6)NOTE: NOTE #6 N/A SEE NEW NOTES.
  
 7)NOTE: NOTE #7 N/A SEE NEW NOTES.
  
 8)NOTE: NOTE #8 N/A SEE NEW NOTES.
  
 9)NOTE: NOTE #9 OK, HOWEVER PLEASE SEE
 NEW NOTE ADDED TO E-2 WHICH MENTIONS A
 "C" AND "A" UNIT(S). ARE THESE THE SAME
 AS A1,ETC AND C1 ETC?? (MISPRINT)?
  
 10)NOTE: NOTE #10 OK.
  
 11)NOTE: NOTE #11 OK.
  
 12)NOTE: NOTE #12 NO, PLEASE SEE
 PREVIOUS NOTES.
  
 13)NOTE: NOTE #13 OK.
  
 14)NOTE: NOTE #14 NO, PLEASE SEE SECOND
 SECTION OF THIS PREVIOUS NOTE.
 PLEASE KNOW THAT POOL IS TO BE A
 SEPARATE PERMIT.
 PLEASE SEE FIRST SECTION OF THIS
 PREVIOUS NOTE WAS ADDRESSED BY REMOVING
 ALL "SITE LIGHTING" POLES FROM SCOPE OF
 WORK AND PLANS. SEE E-1.
  
 15)NOTE: NOTE #15 OK. #'S ADDED.
 HOWEVER PLEASE SEE ONE SET (SHEETS
 A1.1.0 AND A1.2.0 CONTAIN SEALED
 PHOTOCOPIES OF ARCH'S SIGNATURE. PLEASE
 SEE FS 481.221 REQUIRES THE SIGNATURE TO
 BEAN ORIGINAL "WET' SIGNATURE.
 THIS IS ONLY A NOTE.
  
 16)NOTE: NOTE #16 OK.
  
 ***************************************
 NEW NOTES:
  
 1)NOTE: PLEASE SEE PENINSULAR GFI RECEPT
 SPACING MISSING ONE. PLEASE SEE 210.52C3
 AND 4. "B1" SEC FLR.
 PLEASE SEE THE SEPARATION BY THE SINK
 SHOWN, REQUIRES ONE ADDITIONAL GFI.
  
 2)NOTE: PLEASE SEE PANEL SCHEDULES FOR
 SOME UNITS INDICATE PANELS TO BE LOCATED
 IN LAUNDRY RMS, HOWEVER PLEASE SEE PLANS
 E-1ETC SHOW ALL PANELS LOCATED IN
 GARAGES. PLEASE CORRELATE
  
 3)NOTE: PLEASE SEE PANEL SCHEDULES
 INDICATING SOME A/C HEAT AS 10KW,
 HOWEVER LOAD CALCULATIONS, OCP , AWG DO
 NOT CORRELATE. IF INDEED 10KW, PLEASE
 SEE 424.3B FOR MIN OCP TO BE 125%.
 PLEASE ALSO SEE MIN AWG PER 310.16.
 240.4
 PLEASE BE SURE THIS CORRELATES WITH MECH
 PLANS ALSO.
  
 4)NOTE: PLEASE SEE PANEL SCHEDULE
 INDICATES A "NOTE 9" AT LOCATIONS FOR
 A/C UNITS, GATE MOTORS ETC, HOWEVER THE
 PANEL SCHEDULES DO NOT CONTAIN A "NOTE
 9". ONLY SHOWS 1-8
  
 5)NOTE: PLEASE SEE PLANS ARE NOW BEING
 SUBMITTED WITH A COMPLETELY NEW DESIGN
 FOR ELECTRICAL SERVICE AND BLDG
 FEEDS/SERVICES ETC.
 UPON CONVERSATION WITH THE BLDG PLAN
 REVIEWER AND UPON REVIEWING ELECTRICAL
 PLANS, PLANS ARE NOW INDICATING EACH
 BLDG TO BE "SEPARATE".??
 PLEASE SEE ELECTRICAL RISER DIAGRAM NOW
 INDICATES "TWO SEPARATE SERVICES" , ONE
 FOR EACH BLDG. HOWEVER, PLEASE SEE
 ELECTRICAL RISER DIAGRAM ALSO NOW SHOWS
 ONE SERVICE FOR HOUSE ELECTRICAL
 CROSSING OVER AND FEEDING OTHER BLDG.
 THIS IS NOT PERMITTED. 230.2,
 225.30-225.36,230.32 ETC.
  
 PLEASE SEE FIRE ALARM/ SPRINKLER CONTROL
 PANEL IS SHOWN BEING FED FROM ONE HOUSE
 PANEL. DOES THIS PANEL FEED INTO BOTH
 "SEPARATE BLDGS"?IF SO, THIS SHALL NOT
 BE PERMITTED.
  
 PLEASE SEE PLANS APPEAR TO NOW SHOW CATV
 AND PHONE SERVICE COMING INTO ONE BLDG
 AND THEN FEEDING SECOND BLDG? PLEASE
 CLARIFY. EACH BLDG MUST BE FED BY
 SEPARATE SERVICES AND SHALL NOT CONTAIN
 ANY CROSS OVER OF ELECTRICAL SYSTEMS.
  
 6)NOTE: PLEASE SEE LOAD CALCULATIONS.
 PLEASE SEE THERE ARE NUMEROUS AREAS
 WHERE LOADS HAVE NOT BEEN CARRIED
 THROUGH TO MAIN SERVICE LOAD
 CALCULATIONS AND SOME DERATING IS BEING
 TAKEN BEFORE IT IS PERMITTED.
 PLEASE SEE A/C LOADS, 65%, PLEASE SEE
 PREVIOUS NOTES PERTAINING TO THE
 CORRELATION OF KW HEAT LOADS FOR UNITS
 AND SOME BEING SHOWN AS 10KW?
 PLEASE SEE KVA AS SHOWN ON EACH PANEL
 SCHEDULE HAS NOT BEEN CARRIED DOWN TO
 BLDG SERVICE LOAD CALCS. PLEASE SEE EACH
 PANEL LOAD (KVA) HAS BEEN DROPPED BY A
 SMALL AMOUNT. PLEASE CLARIFY WHERE AND
 HOW THIS "DERATING" OR DROPPING OF LOAD
 IS PERMITTED UNDER THE NEC BEFORE MAIN
 BLDG LOAD CALCS?
 PLEASE SEE 220.32
 PLEASE SEE MAIN SERVICE FOR NORTH BLDG
 SHOWS LOAD AFTER ALL DERATING AT 599A'S
 ON A 600A MLO SERVICE. PLEASE SEE LOAD
 AS FIGURED IN NEC WOULD SUBSEQUENTLY
 TAKE SERVICE LOAD OVER THE 600A RATING
 OF EQUIPMENT.
 PLEASE RE-FIGURE LOAD CALCULATIONS AS
 PERMITTED UNDER NEC 220 FOR HOUSE LOADS
 AND FOR MULTI-FAMLIY UNITS.
  
 7)NOTE: PLEASE INDICATE ON RISER DIAGRAM
 THE OCP FOR EACH UNIT. IT APPEARS TO
 SHOW 200A METERS? WITH A NOTE AT UPPER
 CORNER OFEACH RISER INDICATING A 150A
 22K AIC RATED BRKR TO EACH.PLEASE
 REVISED TO MENTION 150A OCP FOR ALL
 UNITS TYPICAL.
  
 8)NOTE: PLEASE SEE ATTACHED COPY OF
 FS 553.80(2)(B) WITH RESPECT TO THE
 DESIGN PROFESSIONAL FOR REPEAT COMMENTS
 FOR CODE COMPLIANCE. THIS IS ONLY A
 NOTICE GIVEN AT THIS TIME AS A COURTESY.
 PLEASE SEE DUE THE THE REPEAT COMMENTS
 AND THE EXTEND OF ELECTRICAL CODE
 COMPLIANCE NOTES ON SECOND REVIEW, ONE
 SET OF ELECTRICAL PLANS ARE BEING
 RETAINED.
  
 9)NOTE: PLEASE SEE ANY POSSIBLE COMMENTS
 FROM OTHER REVIEWER(S) WHICH MAY HAVE AN
 AFFECT ON THE ELECTRICAL SHEETS.
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 ONLY INSERT NEW REVISED SHEETS INTO
 COMPLETE SETS FOR REVIEW AND STAMPING.
 PLEASE SEE ONE SET OF ALL OLD/VOIDED
 SHEETS FROM EACH TRADE SHOULD BE
 SUBMITTED FOR REFERENCE.
  
 ** PLEASE NOTE** A RESPONSE LTR
 CONTAINING PREVIOUS COMMENTS AND REPLIES
 FROM DESIGN PROFESSIONALS HELPS IN THE
 PROCESSING OF PLAN REVIEWS AND
 UNDERSTING OF CODE RELATED
 ITEMS/COMMENTS AND RESPONSES.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESTITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-12-29 Cont ID  
Sent By dpalmer Date 2004-12-29 Time 18:31 Rev Time 2.50
Received By dpalmer Date 2004-12-29 Time 18:30 Sent To  
Notes
2004-12-29 00:00:00**************** UNSAT*****************
  
 1)NOTE: PLEASE SEE PERMIT APPLICATION
 MENTIONS THESE ARE GOING TO BE
 "TOWNHOUSES" YET PLANS FOR ELECTRICAL
 IS
 SET UP FOR WHAT APPEARS TO BE RENTAL
 APARTMENTS???
 IF THESE ARE "TOWNHOUSE" UNITS,
 ELECTRICAL WILL BE REQUIRED TO
 COMPLETELY CHANGE TO INDIVIDUAL
 SERVICES
 TO EACH.
 PLEASE SEE BLDG REVIEW COMMENTS.
  
 2)NOTE: PLEASE SEE 225.31,225.32,225.36
 IF DETACHED BLDGS, MCB WILL BE REQUIRED
 AT EACH PANEL FOR UNITS.
 MEANS SHALL BE PROVIDED FOR
 DISCONNECTING ALL UNGROUNDED CONDUCTORS
 THAT SUPPLY OR PASS THROUGH THE
 BUILDING
 OR STRUCTURE.
 THE DISCONNECTING MEANS SHALL BE
 INSTALLED EITHER INSIDE OR OUTSIDE OF
 THE BUILDING OR STRUCTURE SERVED OR
 WHERE THE CONDUCTORS PASS THROUGH THE
 BUILDING OR STRUCTURE. THE
 DISCONNECTING
 MEANS SHALL BE AT A READILY ACCESSIBLE
 LOCATION NEAREST THE POINT OF ENTRANCE
 OF THE CONDUCTORS.
  
 3)NOTE: PLEASE SEE 225.36 THE
 DISCONNECTING MEANS SPECIFIED IN 225.31
 SHALL BE SUITABLE FOR USE AS SERVICE
 EQUIPMENT
  
 4)NOTE: PLEASE ALSO SEE 225.33 AND 34
 THE DISCONNECTING MEANS FOR EACH SUPPLY
 PERMITTED BY 225.30 SHALL CONSIST OF
 NOT
 MORE THAN SIX SWITCHES OR SIX CIRCUIT
 BREAKERS MOUNTED IN A SINGLE ENCLOSURE,
 IN A GROUP OF SEPARATE ENCLOSURES, OR
 IN
 OR ON A SWITCHBOARD. THERE SHALL BE NO
 MORE THAN SIX DISCONNECTS PER SUPPLY
 GROUPED IN ANY ONE LOCATION.THE TWO TO
 SIX DISCONNECTS AS PERMITTED IN 225.33
 SHALL BE GROUPED. EACH DISCONNECT SHALL
 BE MARKED TO INDICATE THE LOAD SERVED.
  
 5)NOTE: PLEASE SEE GROUNDING AT
 DETACHED
 BLDGS PER 250.32
  
 6)NOTE: PLEASE SEE HP IS SHOWN AS MLO.
 PLEASE SEE ABOVE COMMENTS FOR 225.31
 ETC.
  
 7)NOTE: PLEASE SEE PANEL "H" IS SHOWN
 FED WITH 200A OCP WITH A 165A LOAD
 HOWEVER, THE CONDUCTORS SHOWN (1/0'S)
 ARE ONLY RATED FOR 150A'SPER 310.16,
 240.4B.
  
 8)NOTE: PLEASE SEE E-1, CONDUIT FEED IS
 NOT SHOWN FOR PANEL "H".
  
 9)NOTE: PLEASE SEE PANEL SCHEDULE AND
 LOAD CALCULATIONS MENTIONS A UNIT "C",
 HOWEVER, PLANS SUBMITTED DO NOT
 INDICATE
 A UNIT "C"??
  
 10)NOTE: PLEASE SEE DINING RM RECEPTS
 ARE REQUIRED TO BE ON A 20A #12
 CIRCUIT
 PER 210.52B1,210.11C1
 SOME SHOWN ON WITH LIV RM CIRCUIT.
  
 11)NOTE:: PLEASE SEE UNIT "B1" WITH
 FLEX
 RM. THIS ROOM BEING AN ADAPTABLE
 SLEEPING RM WILL BE REQUIRED TO AHVE A
 SD ALONG WITH ARC FAULT PROTECTION.
 NFPA-72 8-1.4.1.6.2, 210.12
  
 12)NOTE: PLEASE SUBMIT MANUFACTURE
 SPECS
 FOR TANKLESS WATER HEATERS SHOWING A
 LISTING FROM A NRTL.
 PLEASE SEE PANEL "B", THIS SHOWS OCP
 FOR
 THE 16KW UNIT AS 70A? PLEASE SEE PANEL
 "A" IS SHOWN AS 90A.
 PLEASE SEE 422.11F1, ELECTRIC HEATING
 APPLIANCES EMPLOYING RESISTANCE-TYPE
 HEATING ELEMENTS RATED MORE THAN 48
 AMPERES, OTHER THAN HOUSEHOLD
 APPLIANCES
 WITH SURFACE HEATING ELEMENTS COVERED
 BY
 422.11(B), AND COMMERCIAL-TYPE HEATING
 APPLIANCES COVERED BY 422.11(D), SHALL
 HAVE THE HEATING ELEMENTS SUBDIVIDED.
 EACH SUBDIVIDED LOAD SHALL NOT EXCEED
 48
 AMPERES AND SHALL BE PROTECTED AT NOT
 MORE THAN 60 AMPERES.
  
 13)NOTE: PLEASE SEE GDO SHOWN ON GEN
 BRANCH CIRCUIT WITH GARAGE LTS/RECEPTS.
 THIS IS NOT PERMITTED PER 430.32,430.42
 ETC WITH LOAD ON GDO SHOWN.
  
 14)NOTE: PLEASE SUBMIT COMPLETE
 WIND-LOADCALCS ETC FOR ALL SITE
 LIGHTING POLES AND FIXTURES. THESE MUST
 MEET FBC 140MPH.
 PLEASE SEE PLANS DO NOT INDICATE
 WHEATHER OR NOT ANY AFTER DUSK SWIMMING
 WILL TAKE PLACE?
 IF SWIMMING IS ONLY FROM DAWN TO DUSK ,
 PLEASE PLACE NOTE ON PLANS FOR THIS
 TIME
 OF SWIMMING ONLY.
 IF SWIMMING WILL TAKE PLACE AFTER DUSK,
 PLEASE SUBMIT SIGNED AND SEALED
 PHOTOMETRICS TO THE PALM BEACH COUNTY
 HEALTH DEPT FOR REVIEW AND STAMPING.
 PLANS MUST HAVE EITHER.
  
 15)NOTE: PLEASE SEE FAC 61G1-16.004 AND
 FS 481.219 FOR THE REQUIRED CERTIFICATE
 OF AUTHORIZATION NUMBER TO BE PRINTED
 ON
 TITLE BLOCK FOR ARCHITECTUAL FIRM. THIS
 COMMENT DOES NOT APPLY TO ENGINEERING
 FIRM AS CA # IS SHOWN.
 THIS IS REQUIRED ON ALL SHEETS AND FOR
 ALL TRADES WHEATHER OR NOT COMMENT IS
 MADE BY OTHER REVIEWER(S)
  
 16)NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ON EACH LEVEL OF A MULTI-LEVEL DWELLING
 UNIT.
 IN CLOSE PROXIMITY OF STAIRWAYS LEADING
 TO FLOORS ABOVE AND IN THE VICINITY OF
 BEDROOMS.
 PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE
 A MIN OF 3' FROM BATHROOM DOORS AND
 KITCHENS.
 ABOVE PER:FBC 905.2, NFPA-72 8-1.4
 THIS IS A COMMON TEXT NOTE: PLEASE SEE
 MISSING SD ON SECOND FLR.
  
 PLEASE SEE POSSIBLE COMMENTS FROM OTHER
 REVIEWER(S) WHICH MAY HAVE AN AFFECT ON
 ELECTRICAL PLANS.
  
 PLEASE REMOVE ANY OLD/VOIDED SHEETS AND
 ONLY INSERT NEW REVISED SHEETS INTO
 COMPLETE SETS FOR REVIEW AND STAMPING.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2004-12-21 Cont ID  
Sent By mamini Date 2004-12-21 Time 10:51 Rev Time 1.00
Received By mamini Date 2004-12-21 Time 10:51 Sent To  
Notes
2004-12-21 00:00:00PASSED WITH PROVISOS:
  
 1. PLEASE SUBMIT THE CIVIL PLANS ONLY
 TO THE PUBLIC UTILITIES AND ENGINEEING
 SERVICES FOR THEIR REVIEW AND APPROVAL
 OF ALL THE CONNECTION TO THE CITY
 SERVICES, ATT;MANNY GONZALEZ 494-1085.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2005-06-15 Cont ID  
Sent By nmccray Date 2005-06-15 Time 12:43 Rev Time 0.00
Received By nmccray Date 2005-06-15 Time 12:43 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2005-01-20 Cont ID  
Sent By nmccray Date 2005-01-20 Time 12:58 Rev Time 0.00
Received By nmccray Date 2005-01-20 Time 12:57 Sent To  
Notes
2005-01-20 00:00:001) CONTRUCTION WORK IS TO COMPLY WITH
 NFPA 241.
  
 2) BUILDING ADDRESSES ARE REQUIRED.
  
 3) SMOKE DETECTORS SHALL BE PLACED A
 MINIMUM OF THREE FEET FROM AIR
 CONDITIONER DIFFUSERS.
  
 4) IS THE DOOR BETWEEN THE GARAGE AND
 LAUNDRY RATED. NO RATING SHOWN ON DOOR
 SCHEDULE.
  
 5) ELECTRONIC SWITCHES ARE REQUIRED ON
 THE FIRE LINE BACKFLOW DEVICES.
  
 6) FIRE ALARM SYSTEM SHALL BE UL LISTED
 FOR CENTRAL STATION SERVICE.
  
 7) FIRE ALARM SYSTEM SHALL BE CLASS A OR
 FULLY ADDRESSABLE.
  
 8) WHAT IS THE INTERIOR FINISH FOR WALLS
 AND CEILINGS CLASS A, CLASS B, OR CLASS
 C.
  
 9) FIRE EXTINGUISHERS ARE REQUIRED.
  
  
 NATE MCCRAY, CAPTAIN
 561-835-2910 OR 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 23 Status N Date 2009-10-06 Cont ID  
Sent By lmartine Date 2009-10-05 Time 13:36 Rev Time 0.00
Received By lmartine Date 2009-10-06 Time 13:36 Sent To  
Notes
2009-10-06 13:37:13IN ZONING

Review Stop I INCOMING/PROCESSING
Rev No 22 Status N Date 2008-06-05 Cont ID  
Sent By adarroug Date 2008-06-05 Time 13:57 Rev Time 0.00
Received By adarroug Date 2008-06-05 Time 13:57 Sent To B
Notes
2008-06-05 13:57:48TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 21 Status N Date 2008-03-06 Cont ID  
Sent By adarroug Date 2008-03-06 Time 11:46 Rev Time 0.00
Received By adarroug Date 2008-03-06 Time 11:46 Sent To B
Notes
2008-03-06 11:47:07TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 20 Status N Date 2008-02-28 Cont ID  
Sent By adarroug Date 2008-02-28 Time 14:42 Rev Time 0.00
Received By adarroug Date 2008-02-28 Time 14:42 Sent To B
Notes
2008-02-28 14:46:52TO "JWITMER" DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 19 Status N Date 2008-02-28 Cont ID  
Sent By adarroug Date 2008-02-28 Time 13:59 Rev Time 0.00
Received By adarroug Date 2008-02-28 Time 13:59 Sent To M
Notes
2008-02-28 13:59:20TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 18 Status N Date 2006-07-19 Cont ID  
Sent By adarroug Date 2006-07-19 Time 15:56 Rev Time 0.00
Received By adarroug Date 2006-07-19 Time 15:56 Sent To B
Notes
2006-07-19 00:00:00TO "JWITMER" DESK/2 REV'S

Review Stop I INCOMING/PROCESSING
Rev No 17 Status N Date 2006-07-07 Cont ID  
Sent By adarroug Date 2006-07-07 Time 09:44 Rev Time 0.00
Received By adarroug Date 2006-07-07 Time 09:44 Sent To B
Notes
2006-07-07 00:00:00TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2006-06-25 Cont ID  
Sent By adarroug Date 2006-06-25 Time 18:18 Rev Time 0.00
Received By adarroug Date 2006-06-25 Time 18:18 Sent To P
Notes
2006-06-25 00:00:00TO "P" BOX/ 2 REV'S

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2006-06-25 Cont ID  
Sent By adarroug Date 2006-06-25 Time 18:16 Rev Time 0.00
Received By adarroug Date 2006-06-25 Time 18:16 Sent To B
Notes
2006-06-25 00:00:00TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2006-06-12 Cont ID  
Sent By adarroug Date 2006-06-12 Time 11:23 Rev Time 0.00
Received By adarroug Date 2006-06-12 Time 11:23 Sent To B
Notes
2006-06-12 00:00:00TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2006-06-09 Cont ID  
Sent By adarroug Date 2006-06-09 Time 15:44 Rev Time 0.00
Received By adarroug Date 2006-06-09 Time 15:44 Sent To P
Notes
2006-06-09 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2006-03-24 Cont ID  
Sent By dpalmer Date 2006-03-24 Time 14:30 Rev Time 0.00
Received By dpalmer Date 2006-03-24 Time 14:29 Sent To B
Notes
2006-03-24 00:00:00TO JW'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2006-01-20 Cont ID  
Sent By adarroug Date 2006-01-20 Time 12:22 Rev Time 0.00
Received By adarroug Date 2006-01-20 Time 12:22 Sent To B
Notes
2006-01-20 00:00:00TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2005-12-12 Cont ID  
Sent By adarroug Date 2005-12-12 Time 18:41 Rev Time 0.00
Received By adarroug Date 2005-12-12 Time 18:41 Sent To B
Notes
2005-12-12 00:00:00TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2005-11-30 Cont ID  
Sent By adarroug Date 2005-11-30 Time 17:29 Rev Time 0.00
Received By adarroug Date 2005-11-30 Time 17:29 Sent To Z
Notes
2005-11-30 00:00:00TAKEN FROM "COMM" BD#25, AND SENT TO
 ZONING

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-10-22 Cont ID  
Sent By adarroug Date 2005-10-22 Time 10:01 Rev Time 0.00
Received By adarroug Date 2005-10-22 Time 10:01 Sent To B
Notes
2005-10-22 00:00:00TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-10-14 Cont ID  
Sent By adarroug Date 2005-10-14 Time 17:54 Rev Time 0.00
Received By adarroug Date 2005-10-14 Time 17:54 Sent To B
Notes
2005-10-14 00:00:00TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-10-04 Cont ID  
Sent By adarroug Date 2005-10-04 Time 11:34 Rev Time 0.00
Received By adarroug Date 2005-10-04 Time 11:34 Sent To  
Notes
2005-10-14 00:00:00TO "COMM" BD#25
2005-10-04 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-09-09 Cont ID  
Sent By adarroug Date 2005-09-09 Time 09:38 Rev Time 0.00
Received By adarroug Date 2005-09-09 Time 09:38 Sent To  
Notes
2005-09-09 00:00:00TO "COMM" BD#43

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-07-25 Cont ID  
Sent By adarroug Date 2005-07-25 Time 15:02 Rev Time 0.00
Received By adarroug Date 2005-07-25 Time 15:02 Sent To  
Notes
2005-07-28 00:00:00TO "COMM" BD#2/PLANS ON RACK
2005-07-25 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-07-06 Cont ID  
Sent By adarroug Date 2005-07-06 Time 14:29 Rev Time 0.00
Received By adarroug Date 2005-07-06 Time 14:29 Sent To  
Notes
2005-07-12 00:00:00TO "COMM" BD#63
2005-07-06 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-05-16 Cont ID  
Sent By adarroug Date 2005-05-16 Time 09:13 Rev Time 0.00
Received By adarroug Date 2005-05-16 Time 09:13 Sent To  
Notes
2005-05-23 00:00:00TO "COMM" BD#24/PLANS ON RACK
2005-05-16 00:00:00IN INCOMING AWAITING SPACE ON "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By mjacobs Date 2005-01-31 Time   Rev Time 0.00
Received By mjacobs Date 2004-12-17 Time 14:03 Sent To  
Notes
2004-12-17 00:00:00SENT TO "COMM BD#36

Review Stop L LANDSCAPING
Rev No 1 Status P Date 2009-10-07 Cont ID  
Sent By rkussner Date 2009-10-07 Time 17:46 Rev Time 0.00
Received By rkussner Date 2009-10-07 Time 17:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2008-02-29 Cont ID  
Sent By tgordon Date 2008-02-29 Time 08:43 Rev Time 0.25
Received By tgordon Date 2008-02-29 Time 08:43 Sent To  
Notes
2008-02-29 08:43:54REVISION TO MECH. PLAN PAGE M-3.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2007-02-08 Cont ID  
Sent By tgordon Date 2007-02-08 Time 10:57 Rev Time 0.25
Received By tgordon Date 2007-02-08 Time 10:57 Sent To  
Notes
2007-02-08 10:58:28MECH. REVISION TO PLANS PAGE M-2 AND M-3.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2006-06-15 Cont ID  
Sent By tgordon Date 2006-06-15 Time 16:33 Rev Time 0.30
Received By tgordon Date 2006-06-15 Time 16:33 Sent To  
Notes
2006-06-15 00:00:00*** DENIED ***
 REVISION TO ENERGY CAL'S.
 1) BUILDING PERMIT IS UNDER 2001
 BUILDING CODE, SO ENERGY CAL'S. NEED TO
 BE ON FORM 600A-2001, PER 2001 FBC
 13-600.3.A .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-08-19 Cont ID  
Sent By pkrauss Date 2005-08-19 Time 13:54 Rev Time 0.00
Received By pkrauss Date 2005-08-19 Time 07:22 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2005-06-21 Cont ID  
Sent By hmoser Date 2005-06-21 Time 14:58 Rev Time 0.00
Received By hmoser Date 2005-06-21 Time 14:42 Sent To  
Notes
2005-06-21 00:00:00PLAN DENIED
 1) PROVIDE OUTSIDE AIR CALCULATIONS IN
 ACCORDANCE WITH 2001 FBC(M) 402.2 & 2001
 FBC(M) 402.2.1 OR TABLE 403.3.
 2) PLESE PROVIDE EQUIPMENT SCHEDULE ON
 PLANS.
 3) PLEASE REFER TO SECTION 602.2.1
 METERALS EXPOSED WITHIN PLENUMS.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-01-24 Cont ID  
Sent By pkrauss Date 2005-01-24 Time 08:40 Rev Time 1.45
Received By pkrauss Date 2005-01-24 Time 07:38 Sent To  
Notes
2005-01-24 00:00:00DENIED:
 1.ENERGY CALCUALTIONS FOR MODEL A & C
 INDICATE MULTI-FAMILY.ENERGY
 CALCULATIONS FOR A UNIT SHOWS SINGLE
 FAMILY.PLEASE CLARIFY.SEE ALSO
 COMMENT #1 BY JIM WITMER, BUILIDNG PLAN
 REVIEW.
  
 2.PROVIDE OUTSIDE AIR CALCULATIONS IN
 ACCORDANCE WITH 2001 FBC(M)402.2 &
 402.2.1 OR TABLE 403.3.
  
 3.AHU'S SHALL HAVE A MINIMUM OF 4"
 CLEARANCE AROUND UNIT FOR CONSTRUCTION,
 SEALING, INSPECTION AND MAINTENANCE.
 2001 FBC(M)603.1.3.
  
 4. DRYER EXHAUST TERMINATION SHALL BE
 NON-SCREENED BUT EQUIPPED WITH A
 BACKDRAFT DAMPER.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 6 Status P Date 2006-08-15 Cont ID  
Sent By kstevens Date 2006-08-15 Time 08:00 Rev Time 0.00
Received By kstevens Date 2006-08-15 Time 08:00 Sent To  
Notes
2006-08-15 00:00:00REVISIONS OK - SHTS P-2 & P-3 CHANGED
 SANT. AND VENTING FOR W/M, AND SECOND
 FLOOR BATHROOMS.

Review Stop P PLUMBING
Rev No 5 Status F Date 2006-06-12 Cont ID  
Sent By jleech Date 2006-06-12 Time 09:48 Rev Time 0.00
Received By jleech Date 2006-06-12 Time 09:48 Sent To  
Notes
2006-06-12 00:00:00PLUMBING REVISION DENIED;
 B-1 SANITARY RISER DIAGRAM, AUTOMATIC
 CLOTHES WASHER CAN NOT BE INSTALLED AS
 DRAWN DOES NOT MEET CODE SEE FBC-2001
 SECTION 908.3. A MECHANICAL VENT WILL
 ONLY WORK UNDER A NEGATIVE PRESSURE,
 VERTICAL RISERS MAY CREATE A POSITIVE
 PRESSURE. CLEANOUT SHOULD BE INSTALLED
 AT 48" AFF.
 ONE SET OF DRAWINGS MARKED IN RED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 4 Status F Date 2006-05-12 Cont ID  
Sent By mperson Date 2006-05-12 Time 14:31 Rev Time 1.00
Received By mperson Date 2006-05-12 Time 14:31 Sent To PC
Notes
2006-05-12 00:00:00******DENIED******
 REFERENCE: FBC-2001 PLUMBING, AND CITY
 OF WEST PALM BEACH AMENDMENTS TO THE
 FBC-2001, CHAPTER 1, ADMINISTRATION:
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FOR PLAN REVIEW FOR THE PLUMBING
 REVISION:
  
 1. PER FBC-2001 PLBG. SECTION 901.2.1
 VENTING REQUIRED, . THE SHOWER AND TUB
 IN THE MASTER BATH ROOM #303 AND THE
 SHOWER/TUB IN BATH-2 ROOM #306 ARE NOT
 VENTED. PLEASE CORRECT.
 2. PER CITY OF W.P.B. AMENDMENTS,
 SECTION 104.2.1 REQUIREMENTS. THE
 ISOMETRIC DRAWING ON SHEET P-3 DOES NOT
 REFLECT THE FLOOR PLAN OF SHEET P-2. THE
 ISOMETRIC ON SHEET P-3 INDICATES A 3"
 VTR STRAIGHT UP THROUGH THE MASTER BATH
 FLOOR, WHERE SHEET P-2 INDICATES THE 3"
 VENT IN THE WALL BY THE W/C, PLEASE
 CORRELATE THE ISOMETRIC ON P-3 WITH THE
 FLOOR PLAN ON P-2.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-08-26 Cont ID  
Sent By kstevens Date 2005-08-26 Time 16:05 Rev Time 1.00
Received By kstevens Date 2005-08-26 Time 16:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-06-20 Cont ID  
Sent By kstevens Date 2005-06-20 Time 08:29 Rev Time 1.25
Received By kstevens Date 2005-06-20 Time 08:28 Sent To  
Notes
2005-06-20 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATEVE CODE
 FLORIDA STATUTES
  
 FROM PREVIOUS REVIEW:
 2. SHT P-1 INDICATES UNITS C1 & C2, BUT
 NO PLUMBING FLOOR PLANS OR RISER
 DIAGRAMS ARE SUBMITTED. PLEASE CLARIFY.
 SECTION 104.2.1. - NO COMMENT RESPONSE.
 COMMENT NOT ADDRESSED.
 3. SHT P-3 WATER RISER DIAGRAMS. THE
 WATER HAMMER ARRESTORS ARE REQUIRED ANT
 THE WASH MACHINE HOT AND COLD WATER, AT
 THE DISHWASHER, AND AT THE REFRIG. THEY
 WILL BE LOCATED NEAR THE FIXTURE IN AN
 "EFFECTIVE RANGE" NOT IN THE CEILING.
 SECTION 604.9 AND PDI-WH 201. - WATER
 HAMMER ARRESTORS ARE STILL SHOWN IN THE
 CEILING, AND ARE NOT SHOWN AT THE WASH
 MACHINE BOX AS REQUIRED.
 4. SHT P-3 SANITARY RISER DIAGRAM. APT
 B1, 2ND BATH, THIRD FLOOR, SHOWER/TUB
 NOT VENTED. SECTION 901.2.1. - NO
 COMMENT RESPONSE. COMMENT NOT ADDRESSED.
  
 ****************NEW COMMENTS************
 1B. SURVEY SHEETS ARE NOT SIGNED, SEALED
 & DATED AS REQUIRED PER 61G15-23.002(1)
 AND FS 471.025. ALSO ENGINEERS SHALL
 LEGIBLY INDICATE THEIR NAME, ADDRESS,
 AND LICENSE NUMBER ON EACH SHEET. FAC
 61G15-23.002(2)
 2B. SHTS C1.00 THRU C4.00 IF THE DESIGN
 PROFESSIONAL IS AN ARCHITECT OR ENGINEER
 LIGALLY REGISTERED UNDER THE LAWS OF
 THIS STATE REGULATING THE PRACTICE OF
 ARCHITECTURE OR ENGINEERING, THEN HE/SHE
 SHALL AFFIX HIS/HER OFFICIAL SEAL TO
 SAID DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA, AS REQUIRED BY
 FLORIDA STATUTE. SECTION 104.2.2. - ALSO
 ALL LICENSE NUMBERS, CERT. OF
 AUTHORIZATIONS, PRINTED NAME OF DESIGN
 PROFESSIONAL ECT REQUIRED BY FAC & FS.
 3B. SEE ATTACHED SHEET CONCERNING THE
 DESIGN PROFESSIONAL AND FS 553,80(2)(B).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-01-19 Cont ID  
Sent By kstevens Date 2005-01-19 Time 07:49 Rev Time 1.75
Received By kstevens Date 2005-01-18 Time 18:39 Sent To  
Notes
2005-01-19 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) ARCHITECT SHALL SHOW THE CERTIFICATE
 OF AUTHROIZATION ON THE TITLE BLOCK.
 SEE
 61G1-16.004(2) & FS 481.219.
 2) SHT P-1 INDICATES UNITS C1 & C2, BUT
 NO PLUMBING FLOOR PLANS OR RISER
 DIAGRAMS ARE SUBMITTED. PLEAS CLARIFY.
 3) SHT P-3 WATER RISER DIAGRAMS. THE
 WATER HAMMER ARRESTORS ARE REQUIRED AT
 THE WASH MACHINE HOT AND COLD WATER, AT
 THE DISHWASHER, AND AT THE
 REFRIDGERATOR. THEY WILL BE LOCATED
 NEAR
 THE FIXTURE IN AN EFFECTIVE RANGE, NOT
 IN THE CEILING. SECTION 604.9, AND
 PDI-WH 201.
 4) SHT P-3 SANITARY RISER DIAGRAM. APT
 B1, 2ND BATH, THIRD FLOOR, SHWR/TUB NOT
 VENTED. SECTION 901.2.1.
 5) SHT P-4 FIXTURE SCHEDULE, W/M SHOWS
 A
 1-1/2" TRAP. MINIMUM 2" TRAP REQUIRED.
 TABLE 709.1.
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 4 Status P Date 2006-07-06 Cont ID  
Sent By jwitmer Date 2006-07-13 Time 13:13 Rev Time 0.00
Received By eschneid Date 2006-07-06 Time 08:23 Sent To  
Notes
2006-07-06 00:00:00FOR FENCE REVISION TO 72 INCH WOOD
 SHADOW BOX REAR/SIDE.

Review Stop Z ZONING
Rev No 3 Status P Date 2005-12-09 Cont ID  
Sent By eschneid Date 2005-12-09 Time 12:09 Rev Time 0.00
Received By eschneid Date 2005-12-09 Time 12:09 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2005-07-14 Cont ID  
Sent By jlong Date 2005-07-14 Time 12:26 Rev Time 0.00
Received By jlong Date 2005-07-14 Time 12:26 Sent To  
Notes
2005-07-14 00:00:00RECEIVED LETTER FROM MICHAEL HALL OF
 TAYCON CONSTRUCTION STATING THE
 PEDESTRIAN GATE ON THE SITE PLAN IS
 CORRECT AND THE LANDSCAPE PLAN NOW
 INCLUDES THE GATE OF THE ALLEY IN THE
 S.E. CORNER OF THE PROPERTY.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-01-31 Cont ID  
Sent By mmclean Date 2005-01-31 Time 16:56 Rev Time 0.00
Received By jlong Date 2005-07-14 Time 12:19 Sent To  
Notes
2005-01-31 00:00:00REVIEWED BY JOSH LONG, SENIOR PLANNER
 822-1449.DENIED, REAR GATE ON S. PLAN
 & L.S. PLAN DON'T MATCH.CALL JOSH IF
 YOU HAVE ANY QUESTIONS.