| Plan Review Stops For Permit 04120942 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
16 |
Status |
P |
Date |
2008-06-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-06-05 |
Time |
16:52 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2008-06-05 |
Time |
16:52 |
Sent To |
PC |
|
| Notes |
| 2008-06-05 16:53:25 | REVISION SITE WALL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
15 |
Status |
P |
Date |
2008-03-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-03-10 |
Time |
16:48 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2008-03-10 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2008-03-10 16:49:54 | PRODUCT APPROVAL RESTAMPS, | | | LETTERS FROM DESIGN PROFESSIONAL AND REVISION TO POST | | | DETAIL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
P |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-08 |
Time |
07:45 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2007-11-08 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2007-11-08 07:46:27 | RESTAMP PLANS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
P |
Date |
2006-07-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-07-20 |
Time |
07:48 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-07-20 |
Time |
07:48 |
Sent To |
B |
|
| Notes |
| 2006-07-20 00:00:00 | STAIR SHOP DRAWINGS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
P |
Date |
2006-07-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-07-13 |
Time |
07:21 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-07-13 |
Time |
07:46 |
Sent To |
PC |
|
| Notes |
| 2006-07-13 00:00:00 | REVISION FENCE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
F |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-06-15 |
Time |
07:58 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-06-15 |
Time |
07:58 |
Sent To |
PC |
|
| Notes |
| 2006-06-15 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04120942 | | | ADD: 2010 PONCE DE LEON AV | | | CONT: TAYCON | | | TEL: (561)262-2113 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: STAIR SHOP DRAWINGS | | | ACTION: DENIED | | | | | | THE TOP SET OF WINDERS FAILED: | | | 1007.8.1 WINDERS SHALL HAVE A MINIMUM | | | TREAD DEPTH OF 6 INCHES (152 MM) | | | AT THE NARROW EDGE AND SHALL HAVE A | | | MINIMUM TREAD DEPTH OF 11 INCHES (279 | | | MM) AT A POINT 12 INCHES (305 MM) FROM | | | THE NARROW EDGE.WINDERS SHALL BE | | | PERMITTED TO BE USED AS A COMPONENT IN | | | THE MEANS OF EGRESS WITHIN A | | | DWELLING UNIT. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2006-04-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-04-03 |
Time |
09:07 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2006-04-03 |
Time |
09:07 |
Sent To |
PC |
|
| Notes |
| 2006-04-03 00:00:00 | STRUCTURAL REVISIONS, CREATING LOFT IN | | | END UNIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
F |
Date |
2006-04-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-07-13 |
Time |
13:13 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2006-04-03 |
Time |
08:37 |
Sent To |
PC |
|
| Notes |
| 2006-04-03 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04120942/04120945 | | | ADD: 2010 PONCE DE LEON | | | BLDG# 1 | | | BLDG# 2 | | | CONT: TAYCON | | | TEL: (561)282-7310 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: REVISION | | | ACTION: DENIED | | | | | | | | | NO ROOFING PERMIT APPLIED FOR, FOR | | | EITHER BUILDING. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-06 |
Time |
12:24 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2006-02-06 |
Time |
12:02 |
Sent To |
PC |
|
| Notes |
| 2006-02-06 00:00:00 | REV TO TENANT SEPERATION WALL 2HR CONDO |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2005-12-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-12-19 |
Time |
07:12 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-12-19 |
Time |
07:12 |
Sent To |
PC |
|
| Notes |
| 2005-12-19 00:00:00 | REV 9-26-05# 2 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-11-10 |
Time |
16:22 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-11-10 |
Time |
16:22 |
Sent To |
PC |
|
| Notes |
| 2005-11-10 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04120942 | | | ADD: 2010 PONCE DE LEON | | | CONT: TAYCON COSTRUCTION | | | TEL: (561)282-7310 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISIONS: | | | ACTION: DENIED | | | | | | THE REVISION LEGOND IS NOT FILLED OUT ON | | | S-1,S-2, S-3,S-4 & S-5 HAVE DATES BUT DO | | | NOT IDENTIFY WHICH REVISIONS ARE | | | ASSOCIATED WITH THE INDICATED DATES. | | | FL BLD CODE 104.2.1.2* | | | ADDITIONAL INFORMATION REQUIRED. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-11-10 |
Time |
09:46 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2005-11-10 |
Time |
09:46 |
Sent To |
Z |
|
| Notes |
| 2005-11-10 00:00:00 | #5 REVISION TO SITE WALL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-09-27 |
Time |
08:50 |
Rev Time |
4.44 |
| Received By |
jwitmer |
Date |
2005-09-22 |
Time |
15:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-08-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-13 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-08-13 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2005-08-13 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04120942 | | | ADD: 2010 PONCE DE LEON | | | CONT: TAYCON | | | TEL: (561762-0606 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | PRODUCT APPROVALS | | | 1) THE FL COVERSHEET FOR PGT FIXED | | | WINDOWS WAS SUBMITTED BUT NOT THE NOA. | | | | | | 2) THE SAAME HOLDS TRUE WITH THE PGT | | | MULLIONS ONLY THE COVERSHEETWHILE THE | | | REPORT INDICATES VAARIOUS NOA'S ARE | | | COVERED WITHIN THIS REPORT. | | | | | | 3) UNDER THE GARAGE DOOR REPORT | | | HIGHLIGHT OR INDICATE WHICH DOOR OR | | | SERIES YOU ENTENDTO USE? | | | | | | 4) STEEL ROOF PANELS ALSO INDICATE WHICH | | | SYSTEM INSULATED OR NOT? IF USING THE | | | NONINSULATED SYSTEM THE SYSTEM | | | LIMITATION OF A -60 MAXIMUM DESIGN | | | PRESSURE. YOUR ENGINEER CALCULATED AN | | | END ZONE PRESSURE OF -54.1 BUT USING THE | | | TRIBUTARY AREA OF 55 SQ FT. HE NOTES THE | | | END ZONE IS 3'. 3'X3'=9 SQ FT. AGAIN THE | | | | | | TABLES IN 1606.2B INDICATE A -68.1 WHICH | | | WILL REQUIRE ENHANCED FASTENING BY YOUR | | | ENGINEER ONLY FOR ZONE 3. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-08 |
Time |
08:14 |
Rev Time |
8.80 |
| Received By |
jwitmer |
Date |
2005-06-08 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2005-06-08 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT:04120942 | | | ADD: 2010 PONCE DE LEON AV | | | CONT: TAYCON CONSTRUCTION | | | TEL: (561)718-3045 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | | | | | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | SHEET A1.1.0 BUILDING DATA, MISSING | | | INFORMATION FROM TABLE 500, BUILDING | | | TYPE VI, IS PROVIDED, UNPROTECTED IS | | | PROVIDED, BUT THE DECLARATION FOR | | | INCREASE IN HEIGHT, FOOTNOTE "H" IS | | | MISSING, TO ACCOMADATE THE STORY | | | INCREASE (3 STORY). | | | | | | 2A) COMMENT # 1 FROM THE PREVIOUS REVIEW | | | DEALS WITH THE REMOVAL OF THE WORDING | | | "TOWNHOUSE OR TOWNHOMES", THIS | | | TERMINOLOGY IS INDICATED ON THE SOILS | | | REPORT. | | | | | | 2B) SOILS REPORT INDICATES THAT THEY ARE | | | FOR 200-212 SW 9TH AVENUE FT LAUDERDALE | | | | | | 2C) FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITLY KNOWN OR IS IN QUESTION | | | THE BUILDING OFFICIAL MAY REQUIRE EXPLOR | | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | | TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA. | | | | | | 2D) SOILS REPORTS ARE TO BE ORIGINALS | | | WITH RAISED SEAL & SIGNATURES. PLANS, | | | SPECIFICATIONS,REPORTS OR OTHER | | | DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 3) COMMENT # 4 FROM THE PREVIOUS REVIEW, | | | FL BLD CODE CHAP 13 ENERGY EFFICENCY | | | PROVIDE ENERGY CALS, THE GENERAL PROJECT | | | DATA REPORT IS A COPY WITH THE DESIGN | | | PROFESSIONALS COPIED SIGNATURE. | | | PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 4) DEALS WITH THE COMMENT# 12 FROM THE | | | PREVIOUS REVIEW, SEE 411.2.6 FOR | | | OCCUPANCY SEPERATION REQUIRED FROM THE | | | HABITABLE AREAS TO THE GARAGE (R2), THE | | | DOOR SCHEDULE HAS WHITE OUT ON THE | | | SCHEDULE FOR THESE DOORS, THE SECOND | | | ISSUE IS FOR THE (1) HR RATED WALL PLANS | | | INDICATE A "C" LABEL DOOR, TABLE 705.1.2 | | | INDICATES OPENING PROTECTIVES IN MINUTES | | | AND HOURS, PLEASE CORRECT. | | | | | | 5) COMMENT# 15 FROM THE PREVIOUS REVIEW, | | | S-6 TRUSS ANCHORS REQUIRE LOAD | | | REDUCTIONS, 1609.4.3, DETAIL "A",GOOD | | | FOR 11,150 NOT 12,340 SEE 2005 USP | | | CATALOG. | | | | | | 6) COMMENT# 17 FROM THE PREVIOUS REVIEW, | | | S-7 ROOF UPLIFT PRESSURES ARE STILL LOW | | | USE TABLE 1606.2B , ROOF ANGLES > 10-30 | | | DEGREES, WITH MULTIPLIER FROM TABLE | | | 1606.2D "B" = 1.05 FOR 33.83' MEAN ROOF | | | HEIGHT. | | | | | | 7) COMMENT# 18 FROM THE PREVIOUS REVIEW, | | | EITHER THE ARCH OR STRUC SHEETS (ELE) | | | INDICATE THE POS & NEG PRESSURES FOR | | | OPENINGS, INCLUDE ENDZONES AND INTERIOR | | | ZONES, AND MULTIPLIER FOR 33.83 MEAN | | | ROOF HEIGHT. | | | | | | 8)COMMENT# 19 FROM THE PREVIOUS REVIEW | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT | | | APPLICATION AFTER OCTOBER 1, 2003 ARE | | | REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 9)COMMENT# 20 FROM THE PREVIOUS REVIEW, | | | FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) EXTERIOR DOORS THE TESTING REPORT | | | FOR THERMA-TRU DOORS WILL REQUIRE | | | LOCAL PRODUCT APPROVAL, THE | | | MANUFACTURER IS TO FILL OUT THIS | | | | | | FORM. | | | B) TRUSS ANCHORS: PROVIDE THE FLORIDA | | | COVERSHEET FOR, FL 821.8, FL 815.11 | | | & FL 2620.6. | | | C) ROOF ASSEMBLIES:PRODUCT SUBMITTED | | | ENGLERT INC. LOW PRESSURE FOR ZONE# 3. | | | DEPENDING ON WHICH APPLICATION WHICH | | | NONE ARE MARKED AS TO WHICH WILL BE | | | USED, MAY HAVE PRESSURE LIMITATION OF | | | -52.5. | | | THE SECOND ISSUE IS THE DESIGN | | | PROFESSIONAL SPECIFIES A DIFFERENT | | | MANUFACTURER ON THE ELEVATIONS. | | | | | | 10)COMMENT# 23 FROM THE PEVIOUS REVIEW, | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 11) NEW COMMENT, DEALS WITH THE POOL; | | | | | | 11A) THE LOCATION OF THE POOL VS THE | | | LOCATION AND CHANGE IN ELEVATION FOR THE | | | | | | BALCONY FOOTINGS. SEE1803.1.3 | | | EXCAVATION FOR ANY PURPOSE SHALL NOT | | | EXTEND WITHIN 1 FT OF THE ANGLE OF | | | REPOSE OR NARURAL SLOPE OF THE SOIL | | | UNDER ANY FOOTING OR FOUNDATION, UNLESS | | | SUCH FOOTING OR FOUNDATION IS FIRST | | | PROPERLY UNDERPINNED OR PROTECTED | | | AGAINST SETTLEMENT. | | | | | | 11B) ALSO DEALS WITH THE LOCATION OF THE | | | | | | POOL VS. LIVING ROOM WINDOWS. 424.17.1.9 | | | (1) POOLS AND SAFETY ALARMS. | | | | | | NOTE :REVERSED | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-01-13 |
Time |
10:15 |
Rev Time |
8.50 |
| Received By |
jwitmer |
Date |
2005-01-13 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2005-01-13 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT:04120942 | | | ADD: 2010 PONCE DE LEON AV | | | CONT: TAYCON CONSTRUCTION | | | TEL: (561)718-3045 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT | | | NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR | | | SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, THERE | | | SEEMS TO BE A DISCREPANCY IN THE | | | PROJECT | | | BETWEEN THE OCCUPANCY CLASSIFICATION. | | | PERMIT APPLICATIONS INDICATE 8-UNIT | | | TOWNHOMES, WHEREAS IT WAS INPUT INTO | | | THE | | | | | | COMPUTER AS CONDOMINIUM. | | | A1.1.0 PROJECT DATA INDICATES A-2 | | | MULTIFAMILY/ CONDOMINIUM | | | A2.1.1 CONSTRUCTION NOTES: GROUP R-3, | | | 8 SINGLE FAMILY DWELLING TOWNHOMES. | | | PLEASE MAKE CORRECTIONS, IF THIS IS TO | | | BE CONDOMINIUM PLEASE REMOVE ALL | | | TERMINOLOGY TOWNHOMES OR TOWNHOUSES. | | | | | | THIS REVIEW WILL BE COMPLETED WITH THE | | | OCCUPANCY REQUIREMENTS FOR THE GROUP | | | R-2 | | | APARTMENTS & CONDOMINIUM REQUIREMENTS. | | | TYPE V UNPROTECTED / SPRINKLERED. | | | | | | 2)THE PROPOSED BUILDING STRUCTURE | | | TRANSGRESSES LEGAL BOUNDARY LINES | | | BETWEEN THE LOTS WHICH COMBINE TO FORM | | | 'THE SITE'.A 'UNITY OF TITLE' SHALL | | | BE | | | RECORDED AT THE COUNTY COURTHOUSE. | | | SUBMIT A COPY OF THE RECORDED 'UNITY OF | | | OF TITLE' DOCUMENT SO THAT FBC TABLE | | | 600 | | | BOUNDARY LINE REQUIREMENTS MAY BE | | | DEEMED | | | NOT APPLICABLE. | | | | | | 3)FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITLY KNOWN OR IS IN | | | QUESTION | | | THE BUILDING OFFICIAL MAY REQUIRE | | | EXPLOR | | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | | TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA. | | | | | | 4)FL BLD CODE CHAP 13 ENERGY EFFICENCY | | | PROVIDE ENERGY CALS/ W MANUAL "J" | | | CORRECT FORMS (3) NUMBER OF UNITS | | | | | | 5) SHEET A1.1.0 INDICATES THAT THE BACK | | | OF THE BUILDINGS ARE LOCATED 5'-8" AWAY | | | FROM THE PROPERTY LINE. | | | 5A)TABLE 600 REQUIRES THE EXTERIOR | | | WALLS | | | TO BE A 2HR RATING WHEN OVER 3' FROM | | | THE | | | PROPERTY LINE TO 10'-0" AWAY. HAVE THE | | | BLOCK MANUFACTURER PROVIDE THE | | | EQUIVALENT THICKNESS FOR THEBLOCK, | | | SEE | | | 709.3.1. | | | 5B) SINCE THE REAR WALLS ARE LESS THAN | | | 15'-0" FROM THE PROPERTY LINE(ALL | | | FLOORS) ANDA R-2 OCCUPANCY, | | | 705.1.1.2 | | | SHALL REQUIRE OPENING PROTECTIVES FOR | | | THE REAR OPENINGS. | | | | | | 6) THE SAME SITUATION OCCURS ON THE | | | FRONT OF THESE BUILDINGS. TABLE 600 SEE | | | EXTERIOR WALLS BEARING OR NONBEARING | | | REQUIRES 2HR RATED WALLS AND ASSUMED | | | PROPERTY LINES. | | | 6A) PROVIDE BLOCK EQUIVALENT THICKNESS | | | FOR A 2HR RATED BLOCK 709.3.1. | | | 6B) LESS THAN 15' FROM AND ASSUMED | | | PROPERTY LINE REQUIRING OPENING | | | PROTECTIVES. | | | 6C) TABLE 600 ISSUES FRONT OF BUILDING | | | LOCATED 12.66' FROM ASSUMED PROPERTY | | | LINE ALLOWS 20% OPENINGS PER FLOOR. THE | | | | | | FIRST FLOOR OVER THE 20% ALLOWABLE | | | OPENINGS. | | | | | | 7) FBC* 105.3RESIDENT INSPECTOR. | | | SUBMIT INSPECTOR RESUME' AND LICENSE | | | DOCUMENTS TO HAROLD PISKURA, DIRECTOR | | | OF | | | THE RESIDENT INSPECTOR PROGRAM.A | | | RESIDENT INSPECTOR PROGRAM IS REQUIRED, | | | ON THIS PROJECT, DUE TO ONE OR MORE OF | | | THE FOLLOWING: | | | - BUILDINGS/ADDITIONS OF TYPE I OR II | | | CONSTRUCTION | | | - ANY MAJOR STRUCTURAL ALTERATIONS | | | - STRUCTURES IN WHICH THE CONCRETE | | | DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F'C) IN EXCESS OF 3000 PSI | | | - PILE DRIVING | | | - BUILDINGS OVER 20,000 SQFT IN AREA | | | - BUILDINGS OVER 2 STORIES IN HEIGHT | | | - BUILDING/STRUCTURES OF UNUSUAL | | | DESIGN | | | OR METHODS OF CONSTRUCTION | | | | | | 8) NOTE SITE AMENITIES PERMIT WILL BE | | | REQUIRED FOR SITE WALL, GATES, ETC... | | | | | | 9) THE FIRST FLOOR OF ALL CONDOMINIMUM | | | HAVING A RESTROOM OR BATHROOM, | | | 11-4.22.2(1) SHALL HAVE AT LEAST ONE | | | RESTROOM OR | | | BATHROOM WITH A CLEAR OPENING OF 29". | | | SEE DIFINITION OF CLEAR OPENING, | | | MINIMUM | | | WIDTH OF 32". | | | | | | 10) SHEET A2.1.1 & SHEET A2.1.2 BOTH | | | BUILDINGS SHALL MEET THE MAXIMUM STAIR | | | HEIGHT REQUIREMENT OF 7", MINIMUM | | | HEIGHT | | | OF 4" SEE 1007.3.1. | | | | | | 11) STAIR CONSTRUCTION SEE A6.1.0. | | | 1007.1.1 INTERIOR STAIRWAYS SHALL BE | | | CONSTRUCTED OF NONCOMBUSTIBLE MATERIALS | | | THROUGHOUT IN THE FOLLOWING BUILDINGS: | | | (3)ALL BUILDINGS 3 STORIES OR MORE IN | | | HEIGHT. | | | | | | 12) SHEET A2.1.1, A2.1.2 AND A7.3.0 | | | DOOR SCHEDULEPLANS DO NOT INDICATE | | | THE OCCUPANCY SEPERATION REQUIRED FOR | | | THE WALL NOR DOOR, SEE411.2.6 AND TABLE | | | | | | 704.1. | | | | | | 13) SHEET A2.3.1 & A2.3.2 PLANS DOESN'T | | | | | | SHOW WHERE THE ATTIC ACCESS? FL BLD | | | CODE 2309.6 ATTIC ACCESS, PRO- VIDE | | | ATTIC ACCESS 20"X36". | | | | | | 14) VARIOUS SHEETS THROUGHOUT THE PLAN | | | INDICATE CODE SECTIONS REGAURDING | | | ROOFING,1518.9, 1518.2.1,1518.4,& | | | 1517.5.2. THESE CODE SECTIONS ARE FOR | | | HIGH WIND ZONES, DADE & BROWARD | | | COUNTIES | | | AND UNENFORCEABLE. | | | | | | 15) S-5 DETAIL # 1, SEE 2005 USP | | | CATALOG | | | FOR LISTING 2005 HIGH VALUE. SAME | | | DETAIL | | | SHEET S-6 DETAIL# 2. | | | 1609.4.3 LOAD REDUCTION. | | | WHEN STRUCTURAL EFFECTS DUE TO TWO OR | | | MORE LOADS IN COMBINATION WITH DEAD | | | LOAD | | | ARE INVESTIGATED IN LOAD COMBINATIONS | | | OF | | | 1609.4.1 OR 1609.4.2, THE COMBINED | | | EFFECTS DUE TO THE TWO OR LOADS MULTI- | | | PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD | | | LOADS SHALL NOT BE LESS THAN THE | | | EFFECTS | | | FROM THE LOAD COMBINATION OF THE DEAD | | | LOAD PLUS THE LOAD PRODUCING THE | | | LARGEST | | | EFFECTS. INCREAS IN ALLOWABLE STRESS | | | SPE | | | CIFIED IN THE MATERIALS SECTIONS OF | | | THIS | | | CODE OR A REFRENCED STANDARD SHALL NOT | | | BE USED WITH THESE LOAD COMBINATIONS | | | EXCEPT THAT A DURATION OF LOAD INCREASE | | | SHALL BE PERMITTED IN ACCORDANCE WITH | | | CHAPTER 23. | | | | | | 16)S-6 ROOF FRAMING PLAN NOTE # 2, | | | CORRECT NOT IN HIGH VELOCITY ZONE. | | | | | | 17) S-7 ROOF UPLIFT PRESSURES ARE LOW | | | WHEN FIGURING A "C" ZONE WITH HEIGH | | | FACTORS TABLE 1606.2D. REVISE | | | | | | 18)EITHER ON ARCH. OR STRUCTURAL SHEETS | | | (ELE) INDICATE POS & NEG WINDOW & DOOR | | | PRESSURES. THE A7.40 ALLOWABLE WIND | | | LOAD | | | IS GIVEN BUT NOT THE ACTUAL WIND LOADS, | | | NOR INDICATION IF LOCATION IS IN A END | | | ZONE SEE 1606.2D FOR MULTIPLIERS FOR | | | INDICATED "C" ZONE AND HEIGHT FACTORS. | | | | | | 19) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 20)FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A)WINDOWS OPERATABLE & FIXED | | | B) GLASS BLOCK | | | C) MULLIONS | | | D) EXTERIOR SOLID DOORS | | | E) EXTERIOR GLASS/ SLIDING DOORS | | | F) OVERHEAD GARAGE DOORS | | | G) STORM SHUTTERS IF GLAZING NOT | | | TESTED | | | FOR LARGE MISSLE IMPACT | | | H) SIDING | | | I) TRUSS ANCHORS | | | J) ROOFING ASSEMBLIES | | | | | | 21)1707.4.5.1 MULLIONS OCCURRING BETWEEN | | | INDIVIDUAL WINDOW AND GLASS | | | DOOR ASSEMBLIES. TESTING REPORTS ARE | | | REQUIRED BY AN APPROVED TESTING | | | LABORATORY OR BE ENGINEERED. | | | | | | 22)1707.4.5.2 MULLIONS SHALL BE DESIGN- | | | ED TO TRANSFER THE DESIGN PRESSURE LOADS | | | APPLIED BY THE WINDOW OR DOOR ASSEMBLIES | | | TO THE ROUGH OPENING SUBTRATE. | | | | | | 23) BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-22 |
Time |
17:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-09-22 |
Time |
17:49 |
Sent To |
|
|
| Notes |
| 2005-09-22 00:00:00 | ELECTRICAL PLANS STAMPED. | | | | | | | | | | | | | | | ** HIGH LIGHTED PLANS** | | | | | | NO AFTER DUSK SWIMMING PERMITTED |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-09-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-11 |
Time |
10:39 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-09-11 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2005-09-11 00:00:00 | ********** UNSAT **************** | | | | | | | | | PLEASE SEE THE FOLLOWING COMMENTS AS | | | THIS PROJECT IS PLACED ON HOLD FOR | | | ELECTRICAL. | | | | | | 1)NOTE: PLEASE SEE PERMIT APPLICATIONS | | | FOR EACH BLDG DID NOT COME BACK IN WITH | | | PACKAGE. CALLED AND LEFT MESSAGE OR MR. | | | TOM BROWNE. | | | PLEASE ALSO SEE A RESUB COVER SHEET WAS | | | ONLY FILLED OUT AND PLANS WERE ONLY | | | RESUBBED UNDER 04120942 AND DID NOT | | | INLCUDE 04120945. | | | RESUB FEE FOR 04120945 WAS ADDED. | | | | | | 2)NOTE: PLEASE SEE ALL PREVIOUS REVIEWS | | | WHICH REQUESTED ALL OLD/VOIDED SHEETS TO | | | BE COMPLETELY REMOVED FROM SETS AND ONLY | | | INSERT NEW REVISED SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | ONLY ONE SET OF OLD/VOIDED SHEET ARE | | | SUBMITTED SEPARATELYAND NOT IN THE | | | SAME ROLLS. | | | | | | 3)NOTE: PLEASE SEE SHEET A1.2.0 IS STILL | | | A SEALED PHOTO-COPY OF A SIGNED PLAN. | | | PLANS MAY BE RETAINED FOR POSSIBLE | | | REVIEW BY STATE LEGAL COUNSEL TO THE | | | BOARD OF ARCHITECTS AS THIS HAS BEEN | | | REQUESTED ON PREVIOUS REVIEWS TO | | | CORRECT AND NO CHANGES HAVE BEEN MADE. | | | PLEASE SEE FS 481.221. | | | | | | | | | 4) NOTE:PLEASE SEE NO FURTHER | | | ELECTRICAL CORRECTIONS ARE NEEDED. | | | PHOTO-METRICS WILL BE REMOVED AS PART OF | | | THIS PERMIT AS PLANS NOW MENTIONS THERE | | | WILL BE NO NIGHT-TIME SWIMMING. | | | | | | PLEASE ADDRESS THE ABOVE COMMENTS BY | | | CALLING THIS OFFICE TO GO OVER BEFORE | | | PLANS ARE SENT OUT ONCE AGAIN. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-12 |
Time |
21:26 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-07-12 |
Time |
20:41 |
Sent To |
|
|
| Notes |
| 2005-07-12 00:00:00 | IN ELECTRICAL FOR REVIEW. | | | **********UNSAT *********** | | | | | | PLEASE SEE NOTES BELOW> | | | | | | 1)NOTE: PLEASE SEE NOTE #14 FROM FIRST | | | TWO REVIEWS. PLEASE SEE RESPONSE LTR | | | MENTIONS ARCH TO ADDRESS. | | | PLEASE SEE PHOTOMETRICS DO NOT CONTAIN | | | ANY STAMP FROM PALM BEACH COUNTY HEALTH | | | DEPARTMENT FOR NIGHT-TIME SWIMMING. | | | | | | | | | 2)NOTE: PLEASE SEE SHEET E-3 WHICH | | | CONTAINS 3RD FLOOR AND PANEL SCHEDULES | | | FOR PANELS "A" AND "B". PLEASE SEE PANEL | | | SCHEDULES FOR "A" AND "B" WERE MOVED TO | | | E-FOUR, HOWEVER THESE PANEL SCHEDULES | | | WHICH WERE NOT REVISED FOR CORRECTIONS | | | ARE STILL SHOWN ON E-3. ??? | | | PLEASE ALSO SEE ONE SET OF PLANS, SHEET | | | E-3 IS A PHOTOCOPY OF SIGNED,DATED AND | | | SEALED PLANS. | | | FS 471.025 | | | | | | | | | ***NOTE ONLY**** | | | PLEASE ALSO SEE A.1.2.0 OF SAME SET. | | | THIS IS STILL A SEALED PHOTOOPY. THIS | | | WAS CORRECTED ON TWO SETS, BUT NOT | | | THIRD.? SEE BLDG REVIEW COMMENTS FOR | | | A-SHEET. | | | | | | PLEASE REMOVE SAID SHEETS WHICH NEED TO | | | BE CORRECTED. (E-3) AND INSERT NEW | | | REVISED SHEETS INTO COMPLETE SETS FOR | | | REVIEW AND STAMPING. | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-06-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-14 |
Time |
17:34 |
Rev Time |
4.00 |
| Received By |
dpalmer |
Date |
2005-06-14 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2005-06-14 00:00:00 | ************UNSAT 2ND REVIEW ******* | | | | | | *************************************** | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW STILL NEED TO BE ADDRESSED. | | | PLEASE SEE SOME NOTES ARE NOW N/A DUE TO | | | CHANGES IN DESIGN. | | | PLEASE SEE MANY NEW NOTES DUE TO CHANGES | | | ON PLANS. | | | PLEASE SEE THE FIRST SET OF NOTES ARE | | | TAKEN DIRECTLY FROM PREVIOUS REVIEW. | | | | | | 1)NOTE: UNABLE TO VERIFY: PLEASE SEE | | | PERMIT APPLICATION COULD NOT BE LOCATED | | | IN PLANS/PRODUCT APPROVALS/ PACKAGE | | | RESUBMITTED. | | | PLEASE SEE BLDG REVIEW COMMENTS | | | PERTAINING TO THE NOTING OF "TOWNHOUSES" | | | ETC. | | | | | | 2)NOTE: NOTE #2 N/A SEE NEW NOTES. | | | | | | 3)NOTE: NOTE #3 N/A SEE NEW NOTES. | | | | | | 4)NOTE: NOTE #4 N/A SEE NEW NOTES. | | | | | | 5)NOTE: NOTE #5 N/A SEE NEW NOTES. | | | | | | 6)NOTE: NOTE #6 N/A SEE NEW NOTES. | | | | | | 7)NOTE: NOTE #7 N/A SEE NEW NOTES. | | | | | | 8)NOTE: NOTE #8 N/A SEE NEW NOTES. | | | | | | 9)NOTE: NOTE #9 OK, HOWEVER PLEASE SEE | | | NEW NOTE ADDED TO E-2 WHICH MENTIONS A | | | "C" AND "A" UNIT(S). ARE THESE THE SAME | | | AS A1,ETC AND C1 ETC?? (MISPRINT)? | | | | | | 10)NOTE: NOTE #10 OK. | | | | | | 11)NOTE: NOTE #11 OK. | | | | | | 12)NOTE: NOTE #12 NO, PLEASE SEE | | | PREVIOUS NOTES. | | | | | | 13)NOTE: NOTE #13 OK. | | | | | | 14)NOTE: NOTE #14 NO, PLEASE SEE SECOND | | | SECTION OF THIS PREVIOUS NOTE. | | | PLEASE KNOW THAT POOL IS TO BE A | | | SEPARATE PERMIT. | | | PLEASE SEE FIRST SECTION OF THIS | | | PREVIOUS NOTE WAS ADDRESSED BY REMOVING | | | ALL "SITE LIGHTING" POLES FROM SCOPE OF | | | WORK AND PLANS. SEE E-1. | | | | | | 15)NOTE: NOTE #15 OK. #'S ADDED. | | | HOWEVER PLEASE SEE ONE SET (SHEETS | | | A1.1.0 AND A1.2.0 CONTAIN SEALED | | | PHOTOCOPIES OF ARCH'S SIGNATURE. PLEASE | | | SEE FS 481.221 REQUIRES THE SIGNATURE TO | | | BEAN ORIGINAL "WET' SIGNATURE. | | | THIS IS ONLY A NOTE. | | | | | | 16)NOTE: NOTE #16 OK. | | | | | | *************************************** | | | NEW NOTES: | | | | | | 1)NOTE: PLEASE SEE PENINSULAR GFI RECEPT | | | SPACING MISSING ONE. PLEASE SEE 210.52C3 | | | AND 4. "B1" SEC FLR. | | | PLEASE SEE THE SEPARATION BY THE SINK | | | SHOWN, REQUIRES ONE ADDITIONAL GFI. | | | | | | 2)NOTE: PLEASE SEE PANEL SCHEDULES FOR | | | SOME UNITS INDICATE PANELS TO BE LOCATED | | | IN LAUNDRY RMS, HOWEVER PLEASE SEE PLANS | | | E-1ETC SHOW ALL PANELS LOCATED IN | | | GARAGES. PLEASE CORRELATE | | | | | | 3)NOTE: PLEASE SEE PANEL SCHEDULES | | | INDICATING SOME A/C HEAT AS 10KW, | | | HOWEVER LOAD CALCULATIONS, OCP , AWG DO | | | NOT CORRELATE. IF INDEED 10KW, PLEASE | | | SEE 424.3B FOR MIN OCP TO BE 125%. | | | PLEASE ALSO SEE MIN AWG PER 310.16. | | | 240.4 | | | PLEASE BE SURE THIS CORRELATES WITH MECH | | | PLANS ALSO. | | | | | | 4)NOTE: PLEASE SEE PANEL SCHEDULE | | | INDICATES A "NOTE 9" AT LOCATIONS FOR | | | A/C UNITS, GATE MOTORS ETC, HOWEVER THE | | | PANEL SCHEDULES DO NOT CONTAIN A "NOTE | | | 9". ONLY SHOWS 1-8 | | | | | | 5)NOTE: PLEASE SEE PLANS ARE NOW BEING | | | SUBMITTED WITH A COMPLETELY NEW DESIGN | | | FOR ELECTRICAL SERVICE AND BLDG | | | FEEDS/SERVICES ETC. | | | UPON CONVERSATION WITH THE BLDG PLAN | | | REVIEWER AND UPON REVIEWING ELECTRICAL | | | PLANS, PLANS ARE NOW INDICATING EACH | | | BLDG TO BE "SEPARATE".?? | | | PLEASE SEE ELECTRICAL RISER DIAGRAM NOW | | | INDICATES "TWO SEPARATE SERVICES" , ONE | | | FOR EACH BLDG. HOWEVER, PLEASE SEE | | | ELECTRICAL RISER DIAGRAM ALSO NOW SHOWS | | | ONE SERVICE FOR HOUSE ELECTRICAL | | | CROSSING OVER AND FEEDING OTHER BLDG. | | | THIS IS NOT PERMITTED. 230.2, | | | 225.30-225.36,230.32 ETC. | | | | | | PLEASE SEE FIRE ALARM/ SPRINKLER CONTROL | | | PANEL IS SHOWN BEING FED FROM ONE HOUSE | | | PANEL. DOES THIS PANEL FEED INTO BOTH | | | "SEPARATE BLDGS"?IF SO, THIS SHALL NOT | | | BE PERMITTED. | | | | | | PLEASE SEE PLANS APPEAR TO NOW SHOW CATV | | | AND PHONE SERVICE COMING INTO ONE BLDG | | | AND THEN FEEDING SECOND BLDG? PLEASE | | | CLARIFY. EACH BLDG MUST BE FED BY | | | SEPARATE SERVICES AND SHALL NOT CONTAIN | | | ANY CROSS OVER OF ELECTRICAL SYSTEMS. | | | | | | 6)NOTE: PLEASE SEE LOAD CALCULATIONS. | | | PLEASE SEE THERE ARE NUMEROUS AREAS | | | WHERE LOADS HAVE NOT BEEN CARRIED | | | THROUGH TO MAIN SERVICE LOAD | | | CALCULATIONS AND SOME DERATING IS BEING | | | TAKEN BEFORE IT IS PERMITTED. | | | PLEASE SEE A/C LOADS, 65%, PLEASE SEE | | | PREVIOUS NOTES PERTAINING TO THE | | | CORRELATION OF KW HEAT LOADS FOR UNITS | | | AND SOME BEING SHOWN AS 10KW? | | | PLEASE SEE KVA AS SHOWN ON EACH PANEL | | | SCHEDULE HAS NOT BEEN CARRIED DOWN TO | | | BLDG SERVICE LOAD CALCS. PLEASE SEE EACH | | | PANEL LOAD (KVA) HAS BEEN DROPPED BY A | | | SMALL AMOUNT. PLEASE CLARIFY WHERE AND | | | HOW THIS "DERATING" OR DROPPING OF LOAD | | | IS PERMITTED UNDER THE NEC BEFORE MAIN | | | BLDG LOAD CALCS? | | | PLEASE SEE 220.32 | | | PLEASE SEE MAIN SERVICE FOR NORTH BLDG | | | SHOWS LOAD AFTER ALL DERATING AT 599A'S | | | ON A 600A MLO SERVICE. PLEASE SEE LOAD | | | AS FIGURED IN NEC WOULD SUBSEQUENTLY | | | TAKE SERVICE LOAD OVER THE 600A RATING | | | OF EQUIPMENT. | | | PLEASE RE-FIGURE LOAD CALCULATIONS AS | | | PERMITTED UNDER NEC 220 FOR HOUSE LOADS | | | AND FOR MULTI-FAMLIY UNITS. | | | | | | 7)NOTE: PLEASE INDICATE ON RISER DIAGRAM | | | THE OCP FOR EACH UNIT. IT APPEARS TO | | | SHOW 200A METERS? WITH A NOTE AT UPPER | | | CORNER OFEACH RISER INDICATING A 150A | | | 22K AIC RATED BRKR TO EACH.PLEASE | | | REVISED TO MENTION 150A OCP FOR ALL | | | UNITS TYPICAL. | | | | | | 8)NOTE: PLEASE SEE ATTACHED COPY OF | | | FS 553.80(2)(B) WITH RESPECT TO THE | | | DESIGN PROFESSIONAL FOR REPEAT COMMENTS | | | FOR CODE COMPLIANCE. THIS IS ONLY A | | | NOTICE GIVEN AT THIS TIME AS A COURTESY. | | | PLEASE SEE DUE THE THE REPEAT COMMENTS | | | AND THE EXTEND OF ELECTRICAL CODE | | | COMPLIANCE NOTES ON SECOND REVIEW, ONE | | | SET OF ELECTRICAL PLANS ARE BEING | | | RETAINED. | | | | | | 9)NOTE: PLEASE SEE ANY POSSIBLE COMMENTS | | | FROM OTHER REVIEWER(S) WHICH MAY HAVE AN | | | AFFECT ON THE ELECTRICAL SHEETS. | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | PLEASE SEE ONE SET OF ALL OLD/VOIDED | | | SHEETS FROM EACH TRADE SHOULD BE | | | SUBMITTED FOR REFERENCE. | | | | | | ** PLEASE NOTE** A RESPONSE LTR | | | CONTAINING PREVIOUS COMMENTS AND REPLIES | | | FROM DESIGN PROFESSIONALS HELPS IN THE | | | PROCESSING OF PLAN REVIEWS AND | | | UNDERSTING OF CODE RELATED | | | ITEMS/COMMENTS AND RESPONSES. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESTITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-29 |
Time |
18:31 |
Rev Time |
2.50 |
| Received By |
dpalmer |
Date |
2004-12-29 |
Time |
18:30 |
Sent To |
|
|
| Notes |
| 2004-12-29 00:00:00 | **************** UNSAT***************** | | | | | | 1)NOTE: PLEASE SEE PERMIT APPLICATION | | | MENTIONS THESE ARE GOING TO BE | | | "TOWNHOUSES" YET PLANS FOR ELECTRICAL | | | IS | | | SET UP FOR WHAT APPEARS TO BE RENTAL | | | APARTMENTS??? | | | IF THESE ARE "TOWNHOUSE" UNITS, | | | ELECTRICAL WILL BE REQUIRED TO | | | COMPLETELY CHANGE TO INDIVIDUAL | | | SERVICES | | | TO EACH. | | | PLEASE SEE BLDG REVIEW COMMENTS. | | | | | | 2)NOTE: PLEASE SEE 225.31,225.32,225.36 | | | IF DETACHED BLDGS, MCB WILL BE REQUIRED | | | AT EACH PANEL FOR UNITS. | | | MEANS SHALL BE PROVIDED FOR | | | DISCONNECTING ALL UNGROUNDED CONDUCTORS | | | THAT SUPPLY OR PASS THROUGH THE | | | BUILDING | | | OR STRUCTURE. | | | THE DISCONNECTING MEANS SHALL BE | | | INSTALLED EITHER INSIDE OR OUTSIDE OF | | | THE BUILDING OR STRUCTURE SERVED OR | | | WHERE THE CONDUCTORS PASS THROUGH THE | | | BUILDING OR STRUCTURE. THE | | | DISCONNECTING | | | MEANS SHALL BE AT A READILY ACCESSIBLE | | | LOCATION NEAREST THE POINT OF ENTRANCE | | | OF THE CONDUCTORS. | | | | | | 3)NOTE: PLEASE SEE 225.36 THE | | | DISCONNECTING MEANS SPECIFIED IN 225.31 | | | SHALL BE SUITABLE FOR USE AS SERVICE | | | EQUIPMENT | | | | | | 4)NOTE: PLEASE ALSO SEE 225.33 AND 34 | | | THE DISCONNECTING MEANS FOR EACH SUPPLY | | | PERMITTED BY 225.30 SHALL CONSIST OF | | | NOT | | | MORE THAN SIX SWITCHES OR SIX CIRCUIT | | | BREAKERS MOUNTED IN A SINGLE ENCLOSURE, | | | IN A GROUP OF SEPARATE ENCLOSURES, OR | | | IN | | | OR ON A SWITCHBOARD. THERE SHALL BE NO | | | MORE THAN SIX DISCONNECTS PER SUPPLY | | | GROUPED IN ANY ONE LOCATION.THE TWO TO | | | SIX DISCONNECTS AS PERMITTED IN 225.33 | | | SHALL BE GROUPED. EACH DISCONNECT SHALL | | | BE MARKED TO INDICATE THE LOAD SERVED. | | | | | | 5)NOTE: PLEASE SEE GROUNDING AT | | | DETACHED | | | BLDGS PER 250.32 | | | | | | 6)NOTE: PLEASE SEE HP IS SHOWN AS MLO. | | | PLEASE SEE ABOVE COMMENTS FOR 225.31 | | | ETC. | | | | | | 7)NOTE: PLEASE SEE PANEL "H" IS SHOWN | | | FED WITH 200A OCP WITH A 165A LOAD | | | HOWEVER, THE CONDUCTORS SHOWN (1/0'S) | | | ARE ONLY RATED FOR 150A'SPER 310.16, | | | 240.4B. | | | | | | 8)NOTE: PLEASE SEE E-1, CONDUIT FEED IS | | | NOT SHOWN FOR PANEL "H". | | | | | | 9)NOTE: PLEASE SEE PANEL SCHEDULE AND | | | LOAD CALCULATIONS MENTIONS A UNIT "C", | | | HOWEVER, PLANS SUBMITTED DO NOT | | | INDICATE | | | A UNIT "C"?? | | | | | | 10)NOTE: PLEASE SEE DINING RM RECEPTS | | | ARE REQUIRED TO BE ON A 20A #12 | | | CIRCUIT | | | PER 210.52B1,210.11C1 | | | SOME SHOWN ON WITH LIV RM CIRCUIT. | | | | | | 11)NOTE:: PLEASE SEE UNIT "B1" WITH | | | FLEX | | | RM. THIS ROOM BEING AN ADAPTABLE | | | SLEEPING RM WILL BE REQUIRED TO AHVE A | | | SD ALONG WITH ARC FAULT PROTECTION. | | | NFPA-72 8-1.4.1.6.2, 210.12 | | | | | | 12)NOTE: PLEASE SUBMIT MANUFACTURE | | | SPECS | | | FOR TANKLESS WATER HEATERS SHOWING A | | | LISTING FROM A NRTL. | | | PLEASE SEE PANEL "B", THIS SHOWS OCP | | | FOR | | | THE 16KW UNIT AS 70A? PLEASE SEE PANEL | | | "A" IS SHOWN AS 90A. | | | PLEASE SEE 422.11F1, ELECTRIC HEATING | | | APPLIANCES EMPLOYING RESISTANCE-TYPE | | | HEATING ELEMENTS RATED MORE THAN 48 | | | AMPERES, OTHER THAN HOUSEHOLD | | | APPLIANCES | | | WITH SURFACE HEATING ELEMENTS COVERED | | | BY | | | 422.11(B), AND COMMERCIAL-TYPE HEATING | | | APPLIANCES COVERED BY 422.11(D), SHALL | | | HAVE THE HEATING ELEMENTS SUBDIVIDED. | | | EACH SUBDIVIDED LOAD SHALL NOT EXCEED | | | 48 | | | AMPERES AND SHALL BE PROTECTED AT NOT | | | MORE THAN 60 AMPERES. | | | | | | 13)NOTE: PLEASE SEE GDO SHOWN ON GEN | | | BRANCH CIRCUIT WITH GARAGE LTS/RECEPTS. | | | THIS IS NOT PERMITTED PER 430.32,430.42 | | | ETC WITH LOAD ON GDO SHOWN. | | | | | | 14)NOTE: PLEASE SUBMIT COMPLETE | | | WIND-LOADCALCS ETC FOR ALL SITE | | | LIGHTING POLES AND FIXTURES. THESE MUST | | | MEET FBC 140MPH. | | | PLEASE SEE PLANS DO NOT INDICATE | | | WHEATHER OR NOT ANY AFTER DUSK SWIMMING | | | WILL TAKE PLACE? | | | IF SWIMMING IS ONLY FROM DAWN TO DUSK , | | | PLEASE PLACE NOTE ON PLANS FOR THIS | | | TIME | | | OF SWIMMING ONLY. | | | IF SWIMMING WILL TAKE PLACE AFTER DUSK, | | | PLEASE SUBMIT SIGNED AND SEALED | | | PHOTOMETRICS TO THE PALM BEACH COUNTY | | | HEALTH DEPT FOR REVIEW AND STAMPING. | | | PLANS MUST HAVE EITHER. | | | | | | 15)NOTE: PLEASE SEE FAC 61G1-16.004 AND | | | FS 481.219 FOR THE REQUIRED CERTIFICATE | | | OF AUTHORIZATION NUMBER TO BE PRINTED | | | ON | | | TITLE BLOCK FOR ARCHITECTUAL FIRM. THIS | | | COMMENT DOES NOT APPLY TO ENGINEERING | | | FIRM AS CA # IS SHOWN. | | | THIS IS REQUIRED ON ALL SHEETS AND FOR | | | ALL TRADES WHEATHER OR NOT COMMENT IS | | | MADE BY OTHER REVIEWER(S) | | | | | | 16)NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | | UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | | A MIN OF 3' FROM BATHROOM DOORS AND | | | KITCHENS. | | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | | THIS IS A COMMON TEXT NOTE: PLEASE SEE | | | MISSING SD ON SECOND FLR. | | | | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER | | | REVIEWER(S) WHICH MAY HAVE AN AFFECT ON | | | ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ANY OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2004-12-21 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-12-21 |
Time |
10:51 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-12-21 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2004-12-21 00:00:00 | PASSED WITH PROVISOS: | | | | | | 1. PLEASE SUBMIT THE CIVIL PLANS ONLY | | | TO THE PUBLIC UTILITIES AND ENGINEEING | | | SERVICES FOR THEIR REVIEW AND APPROVAL | | | OF ALL THE CONNECTION TO THE CITY | | | SERVICES, ATT;MANNY GONZALEZ 494-1085. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-06-15 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-06-15 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-06-15 |
Time |
12:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-01-20 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-01-20 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2005-01-20 00:00:00 | 1) CONTRUCTION WORK IS TO COMPLY WITH | | | NFPA 241. | | | | | | 2) BUILDING ADDRESSES ARE REQUIRED. | | | | | | 3) SMOKE DETECTORS SHALL BE PLACED A | | | MINIMUM OF THREE FEET FROM AIR | | | CONDITIONER DIFFUSERS. | | | | | | 4) IS THE DOOR BETWEEN THE GARAGE AND | | | LAUNDRY RATED. NO RATING SHOWN ON DOOR | | | SCHEDULE. | | | | | | 5) ELECTRONIC SWITCHES ARE REQUIRED ON | | | THE FIRE LINE BACKFLOW DEVICES. | | | | | | 6) FIRE ALARM SYSTEM SHALL BE UL LISTED | | | FOR CENTRAL STATION SERVICE. | | | | | | 7) FIRE ALARM SYSTEM SHALL BE CLASS A OR | | | FULLY ADDRESSABLE. | | | | | | 8) WHAT IS THE INTERIOR FINISH FOR WALLS | | | AND CEILINGS CLASS A, CLASS B, OR CLASS | | | C. | | | | | | 9) FIRE EXTINGUISHERS ARE REQUIRED. | | | | | | | | | NATE MCCRAY, CAPTAIN | | | 561-835-2910 OR 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
23 |
Status |
N |
Date |
2009-10-06 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-10-05 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-10-06 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2009-10-06 13:37:13 | IN ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
22 |
Status |
N |
Date |
2008-06-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-05 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-05 |
Time |
13:57 |
Sent To |
B |
|
| Notes |
| 2008-06-05 13:57:48 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2008-03-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-06 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-06 |
Time |
11:46 |
Sent To |
B |
|
| Notes |
| 2008-03-06 11:47:07 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2008-02-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-28 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-28 |
Time |
14:42 |
Sent To |
B |
|
| Notes |
| 2008-02-28 14:46:52 | TO "JWITMER" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2008-02-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-28 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-28 |
Time |
13:59 |
Sent To |
M |
|
| Notes |
| 2008-02-28 13:59:20 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2006-07-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-19 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-19 |
Time |
15:56 |
Sent To |
B |
|
| Notes |
| 2006-07-19 00:00:00 | TO "JWITMER" DESK/2 REV'S |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-07 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-07 |
Time |
09:44 |
Sent To |
B |
|
| Notes |
| 2006-07-07 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2006-06-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-25 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-25 |
Time |
18:18 |
Sent To |
P |
|
| Notes |
| 2006-06-25 00:00:00 | TO "P" BOX/ 2 REV'S |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2006-06-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-25 |
Time |
18:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-25 |
Time |
18:16 |
Sent To |
B |
|
| Notes |
| 2006-06-25 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-12 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-12 |
Time |
11:23 |
Sent To |
B |
|
| Notes |
| 2006-06-12 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2006-06-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-09 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-09 |
Time |
15:44 |
Sent To |
P |
|
| Notes |
| 2006-06-09 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-24 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-24 |
Time |
14:29 |
Sent To |
B |
|
| Notes |
| 2006-03-24 00:00:00 | TO JW'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-20 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-20 |
Time |
12:22 |
Sent To |
B |
|
| Notes |
| 2006-01-20 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-12 |
Time |
18:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-12 |
Time |
18:41 |
Sent To |
B |
|
| Notes |
| 2005-12-12 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-11-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-30 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-30 |
Time |
17:29 |
Sent To |
Z |
|
| Notes |
| 2005-11-30 00:00:00 | TAKEN FROM "COMM" BD#25, AND SENT TO | | | ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-22 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-22 |
Time |
10:01 |
Sent To |
B |
|
| Notes |
| 2005-10-22 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-10-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-14 |
Time |
17:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-14 |
Time |
17:54 |
Sent To |
B |
|
| Notes |
| 2005-10-14 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-10-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-04 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-04 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2005-10-14 00:00:00 | TO "COMM" BD#25 | | 2005-10-04 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-09-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-09 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-09 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2005-09-09 00:00:00 | TO "COMM" BD#43 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-07-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-25 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-25 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2005-07-28 00:00:00 | TO "COMM" BD#2/PLANS ON RACK | | 2005-07-25 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-06 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-06 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2005-07-12 00:00:00 | TO "COMM" BD#63 | | 2005-07-06 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-16 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-16 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2005-05-23 00:00:00 | TO "COMM" BD#24/PLANS ON RACK | | 2005-05-16 00:00:00 | IN INCOMING AWAITING SPACE ON "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-17 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2004-12-17 00:00:00 | SENT TO "COMM BD#36 |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2009-10-07 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-10-07 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-10-07 |
Time |
17:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2008-02-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-02-29 |
Time |
08:43 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2008-02-29 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2008-02-29 08:43:54 | REVISION TO MECH. PLAN PAGE M-3. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-02-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-08 |
Time |
10:57 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-02-08 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2007-02-08 10:58:28 | MECH. REVISION TO PLANS PAGE M-2 AND M-3. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-15 |
Time |
16:33 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-06-15 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2006-06-15 00:00:00 | *** DENIED *** | | | REVISION TO ENERGY CAL'S. | | | 1) BUILDING PERMIT IS UNDER 2001 | | | BUILDING CODE, SO ENERGY CAL'S. NEED TO | | | BE ON FORM 600A-2001, PER 2001 FBC | | | 13-600.3.A . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-08-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-08-19 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-08-19 |
Time |
07:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-06-21 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-06-21 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2005-06-21 00:00:00 | PLAN DENIED | | | 1) PROVIDE OUTSIDE AIR CALCULATIONS IN | | | ACCORDANCE WITH 2001 FBC(M) 402.2 & 2001 | | | FBC(M) 402.2.1 OR TABLE 403.3. | | | 2) PLESE PROVIDE EQUIPMENT SCHEDULE ON | | | PLANS. | | | 3) PLEASE REFER TO SECTION 602.2.1 | | | METERALS EXPOSED WITHIN PLENUMS. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-24 |
Time |
08:40 |
Rev Time |
1.45 |
| Received By |
pkrauss |
Date |
2005-01-24 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2005-01-24 00:00:00 | DENIED: | | | 1.ENERGY CALCUALTIONS FOR MODEL A & C | | | INDICATE MULTI-FAMILY.ENERGY | | | CALCULATIONS FOR A UNIT SHOWS SINGLE | | | FAMILY.PLEASE CLARIFY.SEE ALSO | | | COMMENT #1 BY JIM WITMER, BUILIDNG PLAN | | | REVIEW. | | | | | | 2.PROVIDE OUTSIDE AIR CALCULATIONS IN | | | ACCORDANCE WITH 2001 FBC(M)402.2 & | | | 402.2.1 OR TABLE 403.3. | | | | | | 3.AHU'S SHALL HAVE A MINIMUM OF 4" | | | CLEARANCE AROUND UNIT FOR CONSTRUCTION, | | | SEALING, INSPECTION AND MAINTENANCE. | | | 2001 FBC(M)603.1.3. | | | | | | 4. DRYER EXHAUST TERMINATION SHALL BE | | | NON-SCREENED BUT EQUIPPED WITH A | | | BACKDRAFT DAMPER. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2006-08-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-08-15 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-15 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2006-08-15 00:00:00 | REVISIONS OK - SHTS P-2 & P-3 CHANGED | | | SANT. AND VENTING FOR W/M, AND SECOND | | | FLOOR BATHROOMS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-12 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-12 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2006-06-12 00:00:00 | PLUMBING REVISION DENIED; | | | B-1 SANITARY RISER DIAGRAM, AUTOMATIC | | | CLOTHES WASHER CAN NOT BE INSTALLED AS | | | DRAWN DOES NOT MEET CODE SEE FBC-2001 | | | SECTION 908.3. A MECHANICAL VENT WILL | | | ONLY WORK UNDER A NEGATIVE PRESSURE, | | | VERTICAL RISERS MAY CREATE A POSITIVE | | | PRESSURE. CLEANOUT SHOULD BE INSTALLED | | | AT 48" AFF. | | | ONE SET OF DRAWINGS MARKED IN RED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2006-05-12 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-05-12 |
Time |
14:31 |
Rev Time |
1.00 |
| Received By |
mperson |
Date |
2006-05-12 |
Time |
14:31 |
Sent To |
PC |
|
| Notes |
| 2006-05-12 00:00:00 | ******DENIED****** | | | REFERENCE: FBC-2001 PLUMBING, AND CITY | | | OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC-2001, CHAPTER 1, ADMINISTRATION: | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR PLAN REVIEW FOR THE PLUMBING | | | REVISION: | | | | | | 1. PER FBC-2001 PLBG. SECTION 901.2.1 | | | VENTING REQUIRED, . THE SHOWER AND TUB | | | IN THE MASTER BATH ROOM #303 AND THE | | | SHOWER/TUB IN BATH-2 ROOM #306 ARE NOT | | | VENTED. PLEASE CORRECT. | | | 2. PER CITY OF W.P.B. AMENDMENTS, | | | SECTION 104.2.1 REQUIREMENTS. THE | | | ISOMETRIC DRAWING ON SHEET P-3 DOES NOT | | | REFLECT THE FLOOR PLAN OF SHEET P-2. THE | | | ISOMETRIC ON SHEET P-3 INDICATES A 3" | | | VTR STRAIGHT UP THROUGH THE MASTER BATH | | | FLOOR, WHERE SHEET P-2 INDICATES THE 3" | | | VENT IN THE WALL BY THE W/C, PLEASE | | | CORRELATE THE ISOMETRIC ON P-3 WITH THE | | | FLOOR PLAN ON P-2. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-08-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-08-26 |
Time |
16:05 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2005-08-26 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-20 |
Time |
08:29 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2005-06-20 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2005-06-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATEVE CODE | | | FLORIDA STATUTES | | | | | | FROM PREVIOUS REVIEW: | | | 2. SHT P-1 INDICATES UNITS C1 & C2, BUT | | | NO PLUMBING FLOOR PLANS OR RISER | | | DIAGRAMS ARE SUBMITTED. PLEASE CLARIFY. | | | SECTION 104.2.1. - NO COMMENT RESPONSE. | | | COMMENT NOT ADDRESSED. | | | 3. SHT P-3 WATER RISER DIAGRAMS. THE | | | WATER HAMMER ARRESTORS ARE REQUIRED ANT | | | THE WASH MACHINE HOT AND COLD WATER, AT | | | THE DISHWASHER, AND AT THE REFRIG. THEY | | | WILL BE LOCATED NEAR THE FIXTURE IN AN | | | "EFFECTIVE RANGE" NOT IN THE CEILING. | | | SECTION 604.9 AND PDI-WH 201. - WATER | | | HAMMER ARRESTORS ARE STILL SHOWN IN THE | | | CEILING, AND ARE NOT SHOWN AT THE WASH | | | MACHINE BOX AS REQUIRED. | | | 4. SHT P-3 SANITARY RISER DIAGRAM. APT | | | B1, 2ND BATH, THIRD FLOOR, SHOWER/TUB | | | NOT VENTED. SECTION 901.2.1. - NO | | | COMMENT RESPONSE. COMMENT NOT ADDRESSED. | | | | | | ****************NEW COMMENTS************ | | | 1B. SURVEY SHEETS ARE NOT SIGNED, SEALED | | | & DATED AS REQUIRED PER 61G15-23.002(1) | | | AND FS 471.025. ALSO ENGINEERS SHALL | | | LEGIBLY INDICATE THEIR NAME, ADDRESS, | | | AND LICENSE NUMBER ON EACH SHEET. FAC | | | 61G15-23.002(2) | | | 2B. SHTS C1.00 THRU C4.00 IF THE DESIGN | | | PROFESSIONAL IS AN ARCHITECT OR ENGINEER | | | LIGALLY REGISTERED UNDER THE LAWS OF | | | THIS STATE REGULATING THE PRACTICE OF | | | ARCHITECTURE OR ENGINEERING, THEN HE/SHE | | | SHALL AFFIX HIS/HER OFFICIAL SEAL TO | | | SAID DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA, AS REQUIRED BY | | | FLORIDA STATUTE. SECTION 104.2.2. - ALSO | | | ALL LICENSE NUMBERS, CERT. OF | | | AUTHORIZATIONS, PRINTED NAME OF DESIGN | | | PROFESSIONAL ECT REQUIRED BY FAC & FS. | | | 3B. SEE ATTACHED SHEET CONCERNING THE | | | DESIGN PROFESSIONAL AND FS 553,80(2)(B). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-01-19 |
Time |
07:49 |
Rev Time |
1.75 |
| Received By |
kstevens |
Date |
2005-01-18 |
Time |
18:39 |
Sent To |
|
|
| Notes |
| 2005-01-19 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) ARCHITECT SHALL SHOW THE CERTIFICATE | | | OF AUTHROIZATION ON THE TITLE BLOCK. | | | SEE | | | 61G1-16.004(2) & FS 481.219. | | | 2) SHT P-1 INDICATES UNITS C1 & C2, BUT | | | NO PLUMBING FLOOR PLANS OR RISER | | | DIAGRAMS ARE SUBMITTED. PLEAS CLARIFY. | | | 3) SHT P-3 WATER RISER DIAGRAMS. THE | | | WATER HAMMER ARRESTORS ARE REQUIRED AT | | | THE WASH MACHINE HOT AND COLD WATER, AT | | | THE DISHWASHER, AND AT THE | | | REFRIDGERATOR. THEY WILL BE LOCATED | | | NEAR | | | THE FIXTURE IN AN EFFECTIVE RANGE, NOT | | | IN THE CEILING. SECTION 604.9, AND | | | PDI-WH 201. | | | 4) SHT P-3 SANITARY RISER DIAGRAM. APT | | | B1, 2ND BATH, THIRD FLOOR, SHWR/TUB NOT | | | VENTED. SECTION 901.2.1. | | | 5) SHT P-4 FIXTURE SCHEDULE, W/M SHOWS | | | A | | | 1-1/2" TRAP. MINIMUM 2" TRAP REQUIRED. | | | TABLE 709.1. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2006-07-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-07-13 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-07-06 |
Time |
08:23 |
Sent To |
|
|
| Notes |
| 2006-07-06 00:00:00 | FOR FENCE REVISION TO 72 INCH WOOD | | | SHADOW BOX REAR/SIDE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2005-12-09 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2005-12-09 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2005-12-09 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
jlong |
Date |
2005-07-14 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
jlong |
Date |
2005-07-14 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2005-07-14 00:00:00 | RECEIVED LETTER FROM MICHAEL HALL OF | | | TAYCON CONSTRUCTION STATING THE | | | PEDESTRIAN GATE ON THE SITE PLAN IS | | | CORRECT AND THE LANDSCAPE PLAN NOW | | | INCLUDES THE GATE OF THE ALLEY IN THE | | | S.E. CORNER OF THE PROPERTY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-31 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
jlong |
Date |
2005-07-14 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2005-01-31 00:00:00 | REVIEWED BY JOSH LONG, SENIOR PLANNER | | | 822-1449.DENIED, REAR GATE ON S. PLAN | | | & L.S. PLAN DON'T MATCH.CALL JOSH IF | | | YOU HAVE ANY QUESTIONS. |
|
|