| Plan Review Stops For Permit 04120901 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-02-01 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2006-02-01 00:00:00 | REVISE SHEETS A1,A2,A3,A4,S1,S4 AND S5 | | | ARE OK. | | | SUBMITAL FOR ISOKERN FIREPLACE AND | | | SPIRAL STAIRS OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2006-01-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-01-27 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-01-27 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2006-01-27 00:00:00 | REVISIONS DENIED | | | | | | 1) SUBMIT MANUFACTURER'S SPECS. AND | | | INSTALLATION INSTRUCTIONS FOR THE | | | ISOKERN FIREPLACE AND CHIMNEY. SEE | | | PREVIOUS REVIEWS. | | | | | | 2) REVISED STRUCTURAL PLANS ARE REQUIRED | | | TO BE SIGNED, SEALED AND DATED BY THE | | | ENGINEER OF RECORD PER FS 471. | | | | | | 3) THE REVISED ENERGY CALCULATIONS ARE | | | REQUIRED TO BE SIGNED AND DATED BY THE | | | OWNER/AGENT PER 2001 FBC CHAPTER 13. | | | | | | 4) SUBMIT REVISED ELEVATION SHEETS FOR | | | THE ELEVATIONS THAT ARE AFFECTED BY THE | | | REVISED EXTERIOR STAIR AND WINDOW | | | OPENINGS. SEE PREVIOUS REVIEWS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2005-12-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-12-28 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-12-28 |
Time |
07:44 |
Sent To |
P |
|
| Notes |
| 2005-12-29 00:00:00 | REVISIONS DENIED | | | | | | 1) SUBMIT REVISED ENERGY CALCULATIONS | | | FOR R-20 INSULATION. | | | | | | 2) SUBMIT MANUFACTURER'S SPECIFICATIONS | | | AND INSTALLATION INSTRUCTIONS FOR THE | | | ICYNENE INSULATION. | | | | | | 3) ICYENE INSULATION IS TYPICALLY USED | | | FOR UNVENTED ATTICS AND IS INSTALLED ON | | | THE TOP CORD OF THE TRUSSES. THE | | | SECTIONS ON S-4 SPECIFY INSTALLATION ON | | | THE BOTTOM CORD. IF APPLIED TO THE | | | BOTTOM CORD THE ATTIC VENTILATION MUST | | | BE MAINTAINED AND RECESSED LIGHTING WILL | | | BE AFFECTED. PROVIDE MANUFACTURER'S | | | INFORMATION WHICH ADDRESSES THESE ITEMS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-11-10 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-11-10 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2005-11-10 00:00:00 | REVISION DENIED | | | | | | 1) SUBMIT THE MANUFACTURER'S | | | SPECIFICATIONS AND LISTING INFORMATION | | | FOR THE ISOKERN FIREPLACE. | | | | | | 2) THE REVISIONS SPECIFIED ON SHEETS A1 | | | AND A2 AFFECT THE STRUCTURAL PLANS AND | | | ELEVATIONS. PLEASE REVISE ALL AFFECTED | | | PLAN SHEET AND DETAILS. | | | | | | 3) PROVIDE STRUCTURAL DRAWING K ON S5 | | | WHICH IS CALLED OUT ON THE REVISED PLANS | | | BUT NOT SPECIFIED ON THE APPROVED PLANS. | | | | | | 4) PROVIDE THE BEAM ATTACHMENT DETAILS | | | FOR THE EXTENDED PORCH. | | | | | | 5) PROVIDE DETAILS FOR THE SPIRAL | | | STAIRS. | | | | | | 6) THE REVISIONS ALSO AFFECT OTHER | | | TRADES AND ZONING. PLEASE ADDRESS THEIR | | | COMMENTS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-03-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-28 |
Time |
8:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-28 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2005-03-28 00:00:00 | BUILDING PROVISO | | | | | | 1) STRUCTURE IS LOCATED IN AN "A5" FLOOD | | | ZONE AN ELEVATION CERTIFICATE WILL BE | | | REQUIRED. | | | | | | 2) SHOP DRAWINGS WILL BE REQUIRED FOR | | | THE ALUMINUM GUARDRAILS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-02-28 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-02-28 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2005-02-28 00:00:00 | DENIED | | | | | | 1) THE STRUCTURE IS LOCATED IN AN "A5" | | | FLOOD ZONE AN ELEVATION CERTIFICATE WILL | | | BE REQUIRED. | | | | | | 2) SHOP DRAWINGS WILL BE REQUIRED TO BE | | | SUBMITTED FOR THE ALUMNIUM GUARDRAILS. | | | | | | 3)PRODUCT APPROVALS SUBMITTED | | | WITH PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE | | | AT WWW.FLORIDABUILDING.ORG. PRODUCTS | | | WITH STATEWIDE APPROVAL ARE REQUIRED TO | | | BE SUBMITTED WITH A COVER SHEET THAT | | | LISTS THE PRODUCT IDENTITY NUMBER FROM | | | THE STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. | | | A COVER SHEET WITH THE FL PRODUCT | | | APPROVAL NUMBER IS REQUIRED TO BE | | | ATTACHED TO THE MATCHING INSTALLATION | | | INSTRUCTIONS (NOA, ICC EVALUATION | | | REPORT, OR ENGINEERING) FOR ALL WINDOWS, | | | DOORS AND OTHER STRUCTURAL COMPONENTS | | | LISTED IN F.A.C. RULE 9B-72. | | | | | | 4) SUBMIT FL PRODUCT APPROVAL COVER | | | SHEETS FOR THE MULLIONS,SWD-101 FRENCH | | | DOOR, FD-101 FRENCH DOOR WITH SIDELITE, | | | SH-701 SINGLE HUNG WINDOWS AND METAL | | | ROOF SYSTEM. | | | | | | 5) A PRODUCT APPROVAL FOR NON-IMPACT | | | CASEMENT WINDOWS WAS SUBMITTED. SUBMIT | | | STORM PANEL PRODUCT APPROVALS, KEY PLAN | | | AND INSTALLATION SCHEDULE FOR THESE | | | WINDOWS. PLEASE REMOVE FROM SUBMITTALS | | | IF THESE WINDOWS ARE NOT BEING | | | INSTALLED. | | | | | | 6) THE STATE PRODUCT APPROVAL COVER | | | SHEET FOR FD-750 DOORS WERE SUBMITTED | | | WITHOUT THE INSTALLATION INSTRUCTIONS, | | | NOA OR OTHER EVALUATION. PLEASE CORRECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-01-05 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-01-05 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2005-01-05 00:00:00 | DENIED | | | | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) THE STRUCTURES ARE LOCATED IN AN "A5" | | | FLOOD ZONE. AN ELEVATION CERTIFICATE | | | WILL BE REQUIRED. THE MINIMUM ELEVATION | | | IS 7.5', WHICH INCLUDES AN ADDITIONAL | | | 6" PER CITY OF WEST PALM BEACH | | | ORDINANCE. | | | | | | 4) FBC* 1804.2.2AREA OF QUESTIONABLE | | | SOIL.SUBMIT A GEOTECHNICAL REPORT | | | TO VERIFY THE SAFE BEARING CAPACITY OF | | | THE SOIL. | | | | | | 5) SPECIFY THE INSULATION R-VALUE OF THE | | | FLOOR OF THE GUEST HOUSE. SHEET S5 | | | SPECIFIES R-19. | | | | | | 6) SPECIFY ON THE PLANS THAT THE | | | INTERMEDIATE RAILS OF GUARDRAILS AT | | | STAIRS AND BALCONIES ARE REQUIRED TO | | | REJECT A 4" SPHERE AND THE BOTTOM RAIL | | | SHALL REJECT A 2" SPHERE. SEE FBC | | | 1015.3 | | | | | | 7) SPECIFY FIREBLOCKING AT THE ENCLOSED | | | SPACES BETWEEN STAIR STRINGERS AT THE | | | TOP AND BOTTOM OF RUNS. SEE FBC | | | 2305.1.4 | | | | | | 8) ON S1 THE FTG.DETAILS D & I THE PAD | | | FOOTER DEPTH IS INCORRECT. | | | | | | 9) THE GARAGE WALL SECTION 1 ON S5 DOES | | | NOT MATCH THE FTG. DETAIL B ON S1. | | | | | | 10) ON S1 FTG DETAIL B IS INCORRECTLY | | | SPECIFIED AT THE GARAGE DOOR OPENING. | | | | | | 11) THE CITY OF WEST PALM BEACH | | | AMENDMENTS TO FBC TABLE 2306.1 REQUIRES | | | THE ROOF SHEATHING TO BE NAILED AT 4"OC | | | AT EDGES AND 6" OC INTERMEDIATE IN ZONE | | | 3 WHICH INCLUDES THE OUTSIDE CORNERS OF | | | HIP ROOFS. | | | | | | 12) SHOP DRAWINGS WILL BE REQUIRED TO BE | | | SUBMITTED FOR EXTERIOR IRON GUARDRAILS | | | AT STAIRS AND BALCONY FOR APPROVAL PRIOR | | | TO THEIR INSTALLATION. | | | | | | 13) THE EXTERIOR EXITWAY STAIRS AND | | | PORCHES,ETC. ARE REQUIRED TO BE LOCATED | | | A MINIMUM OF 10' FROM ADJACENT PROPERTY | | | LINES. BALCONIES, PORCHES , ETC. SHALL | | | BE NOT LESS THAN 4.5' WIDE. SEE FBC | | | 1006.2.2 | | | | | | 14) FBC 1006.2.4 REQUIRES WINDOWS WITHIN | | | 10' OF EXTERIOR EXIT STAIRS TO HAVE | | | OPENING PROTECTIVES. SEE FBC 1006.2.4 | | | | | | 15) PRODUCT APPROVALS SUBMITTED | | | WITH PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE | | | AT WWW.FLORIDABUILDING.ORG. PRODUCTS | | | WITH STATEWIDE APPROVAL ARE REQUIRED TO | | | BE SUBMITTED WITH A COVER SHEET THAT | | | LISTS THE PRODUCT IDENTITY NUMBER FROM | | | THE STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SUBMIT TWO | | | (2) LEGIBLE COPIES FOR EACH ITEM. | | | | | | 16) SUBMIT (2) TWO CLEAN LEGIBLE COPIES | | | OF ALL PRODUCT APPROVALS. - SUBMIT | | | PRODUCT APPROVALS FOR THE FOLLOWING: | | | - ARCHED TOP DOOR SPECIFIED ON THE PLANS | | | FOR THE CABANA BATH. | | | - THERMA-TRU FIBERGLASS DOOR | | | - CASEMENT WINDOWS | | | - ROOF COVERING FOR FLAT ROOFS | | | - ROOFING MATERIAL AT SUN DECKS | | | - OVERHEAD GARAGE DOOR | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2006-01-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-27 |
Time |
19:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-27 |
Time |
19:33 |
Sent To |
PC |
|
| Notes |
| 2006-01-27 00:00:00 | REV OK, STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-20 |
Time |
20:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-20 |
Time |
20:07 |
Sent To |
|
|
| Notes |
| 2006-01-20 00:00:00 | ********** UNSAT ************* | | | | | | 1)NOTE: PLEASE CORRELATE RISER AND | | | PLANS. PLEASE SEE RISER HAS NOW BEEN | | | REVISED AND SHOWS AN ADDITIONAL RISER?? | | | PLEASE SEE RISER SHOWS CU'S BEING FED | | | FROM THESE OUTDOOR PANELS, HOWEVER NO | | | OCP, AWG, OR LOADS ARE SHOWN FOR THESE | | | CU'S.? | | | PLEASE SEE PLANS INDICATE 3-220V DISC'S | | | NEXT TO METER, PLEASE SEE IT WAS ASSUMED | | | THESE WERE THE DISC'S FOR POOL PUMP, AND | | | CU'S HOWEVER THIS IS NOT CLEAR. PLEASE | | | CORRELATE PLANS WITH SERVICE EQUIPMENT | | | AND RISER DIAGRAM. | | | 215.5 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-12-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-15 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-14 |
Time |
17:00 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-10 |
Time |
18:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-11-10 |
Time |
18:37 |
Sent To |
|
|
| Notes |
| 2005-11-10 00:00:00 | *** UNSAT *** | | | | | | 1)NOTE: PLEASE VERIFY DRYER(S) AND | | | WASHER(S). | | | PLEASE SEE PLANS INDICATE TWO DRYERS AND | | | TWO WASHER RECEPTS SHOWN AT THIS SAME | | | LOCATION, HOWEVER PANEL SCHEDULE AND | | | LOAD CALCULATIONS ONLY INDICATE ONE | | | WASHER? | | | PLEASE ALSO CALRIFY IF THESE UNITS A | | | STACKABLE UNITS AND PERHAPS THE 120V | | | RECEPTS ARE ONLY PLACED FOR POSSIBLE | | | FUTURE INDIVIDUAL UNITS.?? | | | | | | 2)NOTE: PLEASE VERIFY THE LOAD ON GDO'S | | | AS 1/4 HP OR MORE REQUIRES DEDICATED | | | CIRCUITS AND MAY NOT SHARE OTHER MOTOR | | | LOADS.430.53, 430.148 | | | | | | 3)NOTE: PLEASE SEE REDLINED PLANS FOR | | | POSSIBLE MISSING RECEPTS PER 210.52, 2' | | | OF WALL SPACE. | | | PLEASE SEE THAT RAIL AREA IN LOFT RM, IS | | | CONSIDERED WALL SPACE AND WILL BE | | | REQUIRED TO HAVE A RECEPT(FLOOR). | | | | | | | | | 4)NOTE: PLEASE SEE POSSIBLE | | | KITCHEN/BUTLER COUNTERSPACE FOR MISSING | | | GFI RECEPT(S) PER 210.52C1 | | | THESE LOCATIONS ARE REDLINED TO BE | | | VERIFIED. | | | | | | 5)NOTE: PLEASE SEE 210.8A2 WHICH | | | REQUIRES ALL OUTDOOR RECEPT READILY | | | ACCESSIBLE (6 1/2' ) OR LESS TO BE | | | GFI/GFI PROTECTED. | | | REDLINED. | | | | | | 6)NOTE: PLEASE SEE PLANS INDICATE | | | 2-DISPOSAL'S, YET, PANEL SCHEDULES AND | | | LOAD CALCULATIONS, ONLY INDICATE ONE? | | | PLEASE CORRELATE AND ADJUST. | | | 215.5 | | | | | | 7)NOTE: PLEASE SEE LOAD CALCS INDICATE | | | THREE SMALL APPLIANCE CIRCUITS, YET | | | PANEL SCHEDULES ONLY SHOW TWO. | | | PLEASE CORRELATE AND ADJUST AS NESS. | | | 215.5 | | | | | | 8)NOTE: PLEASE CORRLELATE THE NUMBER OF | | | RECESSED LTS ON LOAD CALCULATIONS, WITH | | | THE NUMBER OF FIXTURES SHOWN ON PLANS. | | | PLEASE ADJUST LOAD CALCS AS NEEDED. | | | 215.5, 220.4 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-08 |
Time |
12:40 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-03-08 |
Time |
12:40 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-02-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-24 |
Time |
06:07 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-02-23 |
Time |
18:21 |
Sent To |
P |
|
| Notes |
| 2005-02-24 00:00:00 | ******* UNSAT ******* | | | | | | PLEASE SEE PLANS ARE COMING BACK FOR | | | ZONING COMMENTS. | | | PLEASE CORRECT AT THIS TIME. | | | | | | 1)NOTE: PLEASE SEE RISER HAS NOW | | | INCREASED ORIG 100A PANEL TO 150A'S. | | | PLEASE SEE CONDUCTORS WERE NOT INCREASED | | | FOR 150A'S, PLEASE SEE 310.15B6 MIN, | | | 310.16. | | | PLEASE CORRELATE PANEL , PLEASE SEE | | | PANEL DETAILS LOCATED AT BOTTOM OF PANEL | | | BOTH INDICATE 100A MAIN AND 150A. | | | 215.5 | | | | | | 2)NOTE: PLEASE SEE ELECTRICAL PLANS NOW | | | INDICATE AN OPENING INTO SECOND FLR | | | MEDIA RM, HOWEVER NO MEANS FOR SWITCHING | | | OF EGRESS LIGHTINGIS SHOWN. PLANS | | | REDLINED ON ONE SET. (3-WAY SWITCH)?. | | | | | | 3)NOTE: PLEASE SEE 310.15B6,250.66, DUE | | | TO INCREASE IN SIZE OF SERVICE, PLEASE | | | SEE MIN GROUNDING ELECTRODE CONDUCTOR IS | | | NOW 1/0. PLEASE ADJUST. | | | | | | 4)NOTE: PLEASE SEE EACH SD HAS A RECEPT | | | SHOWN NEXT TO IT? THIS SEEMS TO BE | | | EITHER AT CEILING OR AT FLR? PLEASE | | | VERIFY IF THIS RECEPT IS GOING BE | | | INSTALLED AT EACH SD LOCATION? | | | THIS IS ONLY A NOTE: PLANS ARE COMING | | | BACK AND IF ANY CHANGES NEEDED TO MADE, | | | THIS WOULD SAVE FROM HAVING TO REVISE | | | PLANS AGAIN BEFORE ROUGH. | | | | | | PLEASE SEE ONE SET OF PLANS HAVE AREAS | | | REDLINED AT LOCATIONS FOR NOTES. | | | | | | PLEASE REMOVE OLD/VOIDED SHEETS AND | | | INSERT ONLY NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | 2005-02-23 00:00:00 | FROM ZONIING TO ELECTRIC REVIEW ON | | | 2/19/05 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-23 |
Time |
09:15 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-12-23 |
Time |
09:15 |
Sent To |
M |
|
| Notes |
| 2004-12-23 00:00:00 | ********** UNSAT **************** | | | | | | | | | 1) NOTE: PLEASE LIST ALL THE REQ'D | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3 | | | | | | 2)NOTE: PLEASE SEE 210.52D FOR LOCATION | | | OF GFI RECEPT SPACING TO WITHIN 3' OF | | | SINK EDGE. | | | | | | 3)NOTE: PLEASE SEE 210.63, 210.70 FOR | | | GFI RECETP AND LT REQUIRED FOR AHU | | | OUTSIDE MECH RM. | | | | | | 4)NOTE: PLEASE VERIFY KW LOAD SHOWN FOR | | | WATER HEATER AND OVENS. WH IS SHOWN AS | | | 80 GAL YET ONLY SHOWS 5KW HEAT? | | | PLEASE ALSO SEE DOUBLE OVENS ARE SHOWN | | | WITH 50A OCP YET TWO OVENS ARE ONLY | | | SHOWN WITH 6KW LOAD?? | | | PLEASE VERIFY THE ABOVE AND ADJUST AS | | | NEEDED. | | | | | | 5)NOTE: PLEASE PROVIDE ROOM | | | DESIGNATIONS | | | ON PLANS. | | | | | | 6)NOTE: PLEASE INDICATE GFI FOR | | | JACUZZI/SPA TUB. PER 680 | | | | | | | | | 7 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY | | | NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 8)NOTE: PLEASE SEE ZONING COMMENTS FOR | | | APT AREA SHOWN ABOVE GARAGE. | | | THIS WILL AFFECT ELECTRICAL PLANS. | | | | | | 9)NOTE: PLEASE SEE MAIN HOUSE PANEL IS | | | SHOWN AT DETACHED BLDG. | | | PLEASE SEE 225.31,32,36 | | | 250.31 | | | MEANS SHALL BE PROVIDED FOR | | | DISCONNECTING ALL UNGROUNDED CONDUCTORS | | | THAT SUPPLY OR PASS THROUGH THE BUILDING | | | OR STRUCTURE. | | | THE DISCONNECTING MEANS SHALL BE | | | INSTALLED EITHER INSIDE OR OUTSIDE OF | | | THE BUILDING OR STRUCTURE SERVED OR | | | WHERE THE CONDUCTORS PASS THROUGH THE | | | BUILDING OR STRUCTURE. THE DISCONNECTING | | | MEANS SHALL BE AT A READILY ACCESSIBLE | | | LOCATION NEAREST THE POINT OF ENTRANCE | | | OF THE CONDUCTORS. FOR THE PURPOSES OF | | | THIS SECTION, THE REQUIREMENTS IN 230.6 | | | SHALL BE PERMITTED TO BE UTILIZED. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD SHOULD BE SUBMITTED FOR | | | REFERENCE ONLY. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-01-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-11 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-11 |
Time |
11:36 |
Sent To |
P |
|
| Notes |
| 2006-01-11 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-12 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-12 |
Time |
14:00 |
Sent To |
E |
|
| Notes |
| 2005-12-12 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-10-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-20 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-20 |
Time |
09:07 |
Sent To |
B |
|
| Notes |
| 2005-10-20 00:00:00 | TO "RMCDOUGAL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-10-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-20 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-20 |
Time |
08:20 |
Sent To |
E |
|
| Notes |
| 2005-10-20 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-09-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-15 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-15 |
Time |
16:07 |
Sent To |
P |
|
| Notes |
| 2005-09-15 00:00:00 | TO "JLEECH" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-04-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-01 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-01 |
Time |
09:23 |
Sent To |
Z |
|
| Notes |
| 2005-04-01 00:00:00 | TO "Z" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-03-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-07 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-07 |
Time |
09:08 |
Sent To |
E |
|
| Notes |
| 2005-03-07 00:00:00 | TO DPALMER DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-03-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-03 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-03 |
Time |
11:42 |
Sent To |
Z |
|
| Notes |
| 2005-03-03 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-22 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-22 |
Time |
11:44 |
Sent To |
E |
|
| Notes |
| 2005-02-22 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-07 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-07 |
Time |
14:21 |
Sent To |
Z |
|
| Notes |
| 2005-02-07 00:00:00 | TO "Z"BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-12-22 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-22 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-22 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2004-12-22 00:00:00 | SENT TO "SFR" RACK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-17 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-17 |
Time |
08:43 |
Sent To |
Z |
|
| Notes |
| 2004-12-17 00:00:00 | SENT TO "Z" BOX./NEED ADDRESSING | | | CORRECTIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
N |
Date |
2005-04-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-04-05 |
Time |
13:55 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-04-05 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2005-04-05 00:00:00 | MECHANICAL CONTRACTOR TO APPLY | | | SEPARATELY AND TO SUBMIT PLANS AND | | | MANUAL J CALCS AT THAT TIME (KYLE/ACTION | | | AIR).PER CONVERSATION WITH ROGER | | | THOMAS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-03-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-03-22 |
Time |
18:38 |
Sent To |
B1 |
|
| Notes |
| 2005-03-22 00:00:00 | NO A/C PLANS OR MANUAL (J) | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-02-28 |
Time |
08:17 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-02-28 |
Time |
08:17 |
Sent To |
B |
|
| Notes |
| 2005-02-28 00:00:00 | SECOND MECH. PLAN REVIEW. | | | | | | NO A/C PLAN OR EQUIPMENT INFORMATION | | | . | | | | | | PAT RAFTER 561/805/6728.OR 805/6719. | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2004-12-30 |
Time |
|
Rev Time |
|
| Received By |
hmoser |
Date |
2004-12-30 |
Time |
|
Sent To |
B |
|
| Notes |
| 2004-12-30 00:00:00 | NO MECHANICAL PLANS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2006-01-25 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-01-25 |
Time |
13:44 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2006-01-25 |
Time |
09:22 |
Sent To |
B |
|
| Notes |
| 2006-01-25 00:00:00 | REVISED PLUMBING RISER DIAGRAM | | | (SANITARY) MOVED W/M TO 2ND FLOOR |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2005-12-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-12-29 |
Time |
09:29 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-12-29 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2005-12-29 00:00:00 | DENIED; | | | 1.FIRST FLOOR WASHING MACHINE SHOWN ON | | | SAN. RISER DIAGRAM IS NOT SHOWN ON FLOOR | | | PLAN. | | | 2.THE TWO W/M'S AND SERVICE SINK SHOWN | | | ON PLANS ARE NOT SHOWN ON SAN. RISER | | | DIAGRAM. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-03-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-18 |
Time |
22:09 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2005-03-18 |
Time |
22:09 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-02-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-02-26 |
Time |
10:06 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2005-02-26 |
Time |
10:06 |
Sent To |
M |
|
| Notes |
| 2005-02-26 00:00:00 | DENIED; | | | 1.LAUNDRY TUB REQUIRED TO DISCHARGE | | | ABOVE WASHER. | | | 2.CLOTHS WASHER WASTE ARM AND TRAP TO BE | | | TWO INCH. | | | 3.RISER DIAGRAM DOES NOT MATCH FLOOR | | | PLAN.(LAUNDRY ROOM ON SAME WALL AS | | | KITCHEN, LAUNDRY ROOM IS NEAR DINING | | | ROOM KITCHEN IS NEAR GARAGE. 3' RISERS | | | FOR 2ND FLOOR ARE OUTSIDE HOUSE) | | | 4.3" RISERS FOR 2ND FLOOR REQUIRE A 6" | | | WALL PLEASE SHOW ON DRAWING. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-12-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-12-27 |
Time |
13:46 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2004-12-27 |
Time |
13:46 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2005-04-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-04-05 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-04-05 |
Time |
11:30 |
Sent To |
M |
|
| Notes |
| 2005-04-05 00:00:00 | NOTE: MUST PULL SEPERATE PERMIT FOR | | | POOL/SPA/DECK/SCREEN ENCLOSURE. ALSO, | | | FOR FENCE/WALL/GATE WITH CITY OF WEST | | | PALM UTILILTY DEPT, UTILITY EASEMENT | | | APPROVAL.CANNOT PUT GATE/WALL IN 15FT | | | UE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2005-03-04 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-04 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-04 |
Time |
16:53 |
Sent To |
I |
|
| Notes |
| 2005-03-04 00:00:00 | DENIED, | | | 1. SITEPLAN & APPLICATION DOES NOT MATCH | | | LOTS (SITEPLAN LOT 141 AND APPLCIATION | | | 1/2 LOF 135, 136, 137.NEED TO BE | | | CORRECTED. | | | 2. CANNOT HAVE GUEST HOUSE IN SF7, MUST | | | CHANGE APPLICATION AND COMPUTER SCREEN | | | TO SAY "MEDIA ROOM" | | | | | | NOTE: SEPARATE PERMIT MUST BE PULLED FOR | | | POOL/SPA/DECK/SCREEN ENCLOSURE. ALL | | | REFRIDGERATOR EXCEPT FOR KITCHEN SHOULD | | | HAVE ON PLANS U/C REFRIDGERATOR. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | CONSTRUCTION SERVICES | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2005-02-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-02-18 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-02-18 |
Time |
09:21 |
Sent To |
I |
|
| Notes |
| 2005-02-18 00:00:00 | DENIED, | | | 1. MUST HAVE A REGULAR DOOR OPENING ON | | | THE 2ND FLOOR (MEDIA ROOM), IN ORDER TO | | | HAVE EXTERIOR STAIRS. | | | 2. MUST REMOVE ON APPLICATION AND | | | COMPUTER SCREEN GUEST HOUSE. ZONED SF7. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | CONSTRUCTION SERVICES | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-12-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-12-22 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-12-22 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2005-04-05 00:00:00 | THE ABOVE NOTES DOES NOT MATCH COMMENTS | | | TO THIS PERMIT.DEAN R CHANGED PLANS | | | AND DID NOT MAKE CHANGES TO THE PLAN | | | REVIEW COMMENTS. | | 2004-12-22 00:00:00 | DENIED, ZONED SF7, NO OTHER LIVING | | | QUARTERS ALLOWED WITH MAIN STRUCTURE. | | | CANNOT HAVE EXTERIOR STAIRS.ACCESSORY | | | STUCTURE MUST BE A MIN OF 6FT FROM MAIN | | | STRUCTURE AND ONLY A GAME ROOM ALLOWED. | | | CALLED ROGER CONTRACTOR. |
|
|