Plan Review Details - Permit 04120780
Plan Review Stops For Permit 04120780
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-01-20 Cont ID  
Sent By jwitmer Date 2005-01-20 Time 07:03 Rev Time 0.55
Received By jwitmer Date 2005-01-20 Time 07:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-01-07 Cont ID  
Sent By jwitmer Date 2005-01-07 Time 08:51 Rev Time 1.11
Received By jwitmer Date 2005-01-07 Time 08:51 Sent To  
Notes
2005-01-07 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04120780
 ADD: 225 S. OLIVE
 CONT: NICK RAICH BUILDING CORP
 TEL: (561)718-1224
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) VALUE LOW FOR JOB.
  
 2) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 3)ALL INFORMATION, DRAWINGS, SPECIF-
 ICATIONS AND ACCOMPANYING DATA SHALL
 BEAR THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN.
 CITY AMENDMENTS 104.2.1*
  
 4) PLANS DO NOT INDICATE USE OR
 OCCUPANCY 301.2.
  
 5)TABLE 803.3 MINIMUM INTERIOR FINISH
 CLASSIFICATION; PROVIDE INFORMATION
 BASED ON INTERIOR FINISH REQUIREMENTS
 BASED ON OCCUPANCY.
  
 6)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 104.2.1.3 QUALITY OF PLANS MINIMUM OF
 1/8".
  
 7) 11-4.13.6 MANEUVERING CLEARENCES
 AT DOORS. MINIMUM MANEUVERING CLEARENCES
 AT DOORS THAT ARE NOT AUTOMATIC OR
 POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITH
 IN THE REQUIRED CLEARENCES SHALL BE
 CLEAR & LEVEL.
 THE ROOM WWITH THE WIDTH OF 8'-2"
 DOES NOT HAVE 18" CLEAR ONTHE PULL
 SIDE.
  
 8) PLANS DO NOT INDICATE A HANDICAPPED
 RESTROOM SHOW COMPLIANCE WITH:
 11-4.1.6(2) DUTY TO PROVIDE AN
 ACCESSIBLE PATH OF TRAVEL TO ALTERED
 AREAS SHALL BE DEEMED DISPROPORTIONATE
 TO THE OVERALL ALTERATION WHEN THE COST
 EXCEEDS 20 % OF THE COST OF THE ALTERA-
 TION TO THE PRIMARY FUNCTION AREA.
 (A)(I) AN ACCESSIBLE ENTRANCE
 (II) AN ACCESSIBLE ROUTE
 (III) AT LEAST ONE ACCESSIBLE REST-
 ROOM FOR EACH SEX OR A SINGLE
 UNISEX RESTROOM
 (IIII) ACCESSIBLE TELEPHONE
 (IV) ELEMENTS SUCH AS PARKING, STOR-
 AGE OR ALARMS.
  
 9) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 IS THERE A BREAK ROOM WITH SINK? IF SO:
 11-4.24.2 SINKS, HEIGHT. SINKS SHALL
 BE MOUNTED WITH THE COUNTER NO HIGHER
 THAN 34" ABOVE THE FINISH FLOOR.
 11-4.24.3 KNEE CLEARENCE THAT IS AT
 LEAST 27" HIGH 30" WIDE, AND 19" DEEP
 SHALL BE PROVIDED UNDERNEATH SINKS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2004-12-23 Cont ID  
Sent By dpalmer Date 2004-12-23 Time 11:00 Rev Time 0.10
Received By dpalmer Date 2004-12-23 Time 11:00 Sent To  
Notes
2004-12-23 00:00:00NO ELECTRICAL SHOWN
  
 PLANS ARE REQUIRED TO HAVE PRINTED NAME
 AND SIGNATURE OF THE PERSON RESPONSIBLE
 FOR PLANS. FBC 104.2.1

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2005-01-31 Cont ID  
Sent By nmccray Date 2005-01-31 Time 14:23 Rev Time 0.00
Received By nmccray Date 2005-01-31 Time 14:23 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-12-30 Cont ID  
Sent By mwennerg Date 2004-12-30 Time 13:05 Rev Time 0.00
Received By mwennerg Date 2004-12-30 Time 13:05 Sent To  
Notes
2004-12-30 00:00:001) WHAT ARE THE LOCATIONS OF EXITS SIGNS
 AND EMERGENCY LIGHTS?
 2) PLANS DON'T SHOW INTERIOR FINISH
 INFORMATION. PLEASE PROVIDE
 INFORMATION.
 3) WHAT SCALE WAS USED FOR THE DRAWING?
 4) PLEASE SUBMIT SHOP DRAWINGS ON FIRE
 SPRINKLER AND ALARM REMODEL IF
 NECESSARY.
  
  
 M.R. WENNERGREN, A/CAPT.
 WPBFR(561) 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-14 Cont ID  
Sent By mjacobs Date 2005-01-14 Time 13:48 Rev Time 0.00
Received By mjacobs Date 2005-01-14 Time 13:48 Sent To  
Notes
2005-01-14 00:00:00TO "COMM BD#44"/RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-12-15 Cont ID  
Sent By mjacobs Date   Time   Rev Time 0.00
Received By mjacobs Date 2004-12-15 Time 16:21 Sent To  
Notes
2004-12-15 00:00:00SENT TO "COMM BD#26

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-01-10 Cont ID  
Sent By pkrauss Date 2005-01-10 Time 08:03 Rev Time 0.15
Received By pkrauss Date 2005-01-10 Time 08:03 Sent To  
Notes
2005-01-10 00:00:00NO MECHANICAL PLANS OR CONTRACTOR
 INDICATED WITH PERMIT APPLICATION.
 PLEASE PROVIDE PLANS WITH MECHANICAL
 PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.
  