| Plan Review Stops For Permit 04120738 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-05-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-05-13 |
Time |
15:40 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-05-13 |
Time |
15:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-02-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-02-18 |
Time |
08:11 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-02-18 |
Time |
08:11 |
Sent To |
|
|
| Notes |
| 2005-02-18 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEE PREVIOUS LIST, PROVIDE DETAILS | | | FOR THE GRAB BARS TO SHOW COMPLIANCE | | | WITH FBC CHAPTER 11.FBC11-4.17.6 | | | REQUIRES GRAB BARS IN COMPLIANCE WITH | | | FBC CHAPTER 11 FIGURE 30(A) THROUGH (D). | | | THE DETAIL PROVIDED FOR THE SIDE GRAB | | | BAR DOES NOT GIVE A LENGTH.A GRAB BAR | | | AT THE BACK OF THE TOILET IS SHOWN | | | GRAPHICALLY ON THE FLOOR PLAN BUT DOES | | | NOT APPEAR COMPLIANT WITH FIGURE 30. | | | THE REAR GRAB BAR IS NOT SHOWN AT ALL ON | | | SECTION B. | | | | | | 2.)SHOW KNEE CLEARANCE FOR THE SINK, | | | FBC11-4.24.3.THE PIPES ARE TO BE | | | INSULATED, FBC11-4.24.6.NONE SHOWN ON | | | THE DETAIL. | | | | | | 3.)CONTACT PALM BEACH COUNTY IMPACT | | | FEES TO DETERMINE POSSIBLE IMPACT FEES | | | DUE (CHANGE OF USE).233-5025.THE | | | PLANS ARE TO BE STAMPED AND THE RECEIPT | | | ATTACHED TO THE APPLICATION. | | | | | | 4.)SEE ATTACHED FS553.80(2)(B). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-01-12 |
Time |
15:18 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-01-12 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2005-01-12 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS | | | EXAMINER | | | [email protected] | | | | | | 1.)PROVIDE DETAILS FOR THE KITCHEN | | | SINK, BATHROOM SINK, GRAB BARS, WC TO | | | COMPLY WITH FBC CHAPTER 11. | | | | | | 2.)SHOW MANEUVERING CLEARANCE (FBC | | | CHAPTER 11,FIGURE 25) FOR THE FOLLOWING | | | DOORS: | | | OFFICE 102, BATHROOM 108, ENTRY DOOR TO | | | UNIT 316, BATHROOM 112, OFFICE 117, | | | OFFICE 118. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-07-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-18 |
Time |
08:44 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-07-18 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2005-07-18 00:00:00 | LTR FROM ENG, OK TO AHVE NO CONDUIT FOR | | | PHONE LINES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-12-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-28 |
Time |
06:09 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-12-28 |
Time |
06:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2004-12-30 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2004-12-30 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2004-12-30 00:00:00 | 1) PROVIDE SHOP DRAWINGS FOR SPRINKLER | | | AND FIRE ALARM REMODEL. | | | 2) PLEASE PROVIDE INFORMATION REGARDING | | | INTERIOR FINISH OF FLOOR AND WALLS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-13 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-13 |
Time |
10:43 |
Sent To |
E |
|
| Notes |
| 2005-07-13 00:00:00 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-05-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-10 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-03 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2005-05-10 00:00:00 | TO "COMM" BD#10 | | 2005-05-03 00:00:00 | IN THROUGH INCOMING/WAITING FOR SPACE ON | | | "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-25 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-25 |
Time |
15:42 |
Sent To |
P |
|
| Notes |
| 2005-02-25 00:00:00 | TO KSTEVENS DESK/RESUB | | | TAKEN FROM BD#15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-15 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-15 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2005-02-15 00:00:00 | TO "COMM" BD#15/RESUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-14 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2004-12-21 |
Time |
07:14 |
Sent To |
|
|
| Notes |
| 2004-12-21 00:00:00 | SENT TO "COMM BD#44" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-06 |
Time |
07:26 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-01-06 |
Time |
07:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2005-05-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-05-14 |
Time |
17:19 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2005-05-14 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2005-05-14 00:00:00 | PASSED/PROVISO | | | | | | | | | 11-4.19.4 EXPOSED PIPES AND SURFACES. | | | HOT WATER AND DRAIN PIPES UNDER | | | LAVATORIES SHALL BE INSULATED OR | | | OTHERWISE CONFIGURED TO PROTECT AGAINST | | | CONTACT. THERE SHALL BE NO SHARP OR | | | ABRASIVE SURFACES UNDER LAVATORIES. | | | | | | | | | 11-4.19.5 FAUCETS. FAUCETS SHALL COOMPLY | | | WITH 11-4.27.4. LEVER-OPERATED, | | | PUSH-TYPE, AND ELECTRONICALLY CONTROLLED | | | MECHANISMS ARE EXAMPLES OF ACCEPTABLE | | | DESIGNS. IF SELF-CLOSING VALVES ARE USED | | | THE FAUCET SHALL REMAIN OPEN FOR AT | | | LEAST 10 SECONDS. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | . |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-01 |
Time |
09:13 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2005-03-01 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2005-03-01 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | FROM PREVIOUS REVIEW: | | | SUBMIT A DETAIL FOR THE KITCHEN SINK | | | SHOWING COMPLIANCE WITH THE FOLLOWING: | | | A) KNEE CLEARANCE 11-4.24.3 | | | B) SINK DEPTH 11-4.24.4 | | | C) CLEAR FLOOR SPACE 11-4.24.5 (THE | | | CLEAR FLOOR SPACE SHALL BE PROVIDED IN | | | FRONT OF A SINK TO ALLOW FORWARD | | | APPROACH. THE CLEAR FLOOR SPACE SHALL BE | | | ON AN ACCESSIBLE ROUTE AND SHALL EXTEND | | | A MAXIMUM OF 19" UNDERNEATH THE SINK). | | | (SEE FIGURE 32). PARALLEL APPROACH IS | | | NOT APPROVED. | | | D) EXPOSED PIPES AND SURFACES 11-4.24.6 | | | E) FAUCETS 11-4.24.7 | | | *****THIS INFORMATION SHALL BE INCLUDED | | | ON THE PLANS. SUCH INFORMATION SHALL BE | | | SPECIFIC, AND THE TECHNICAL CODES SHALL | | | NOT BE CITED AS A WHOLE OR IN PART, NOR | | | SHALL THE TERM "LEGAL" OR ITS EQUIVALENT | | | BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION. SECTION 104.2.1.***** | | | 2) SUBMIT A DETAIL FOR THE TOILET ROOMS | | | SHOWING THE FOLLOWING INFORMATION: | | | B) TOILET TO BE 18" OFF THE WALL TO THE | | | CENTERLINE OF THE FIXTURE. FIG. 28 | | | D) GRAB BARS 11-4.16.4 GRAB BARS FOR | | | WATER CLOSETS NOT LOCATED IN STALLS | | | SHALL COMPLY WITH 11-4.26 AND FIGURE 29. | | | FLOOR MOUNTED GRAB BARS ARE NOT APPROVED | | | PER THIS SECTION OF THE CODE. | | | E) FLUSH CONTROLS 11-4.16.5 - NO | | | RESPONSE TO THIS REQUEST NOTED. | | | G) EXPOSED PIPES & SURFACES 11-4.19.4 - | | | NO RESPONSE TO THIS REQUEST NOTED. | | | H) FAUCET 11-4.19.5 | | | *************NEW COMMENT********* | | | SEE SHEET CONCERNING DESIGN PROFESSIONAL | | | AND FLA. STATUTE 553.80(2)(B) SUBMITTED | | | BY THE STRUCTURAL PLAN REVIEWER. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-01-14 |
Time |
07:45 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2005-01-14 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2005-01-14 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) SUBMIT A DETAIL FOR THE KITCHEN SINK | | | SHOWING THE FOLLOWING INFORMATION: | | | A) KNEE CLEARANCE 11-4.24.3 | | | B) SINK DEPTH 11-4.24.4 | | | C) CLEAR FLOOR SPACE (SHALL BE PROVIDED | | | TO ALLOW FORWARD APPROACH AND SHALL | | | EXTEND A MAXIMUM OF 19" UNDERNEATH THE | | | SINK). 11-4.24.5. | | | D) EXPOSED PIPES AND SURFACES | | | 11-4.24.6 | | | 3) FAUCETS 11-4.24.7 | | | 2) SUBMIT A DETAIL FOR THE TOILET ROOMS | | | SHOWING THE FOLLOWING INFORMATION: | | | A) FOR THE TOILET - CLEAR FLOOR SPACE | | | 11-4.16.2 | | | B) TOILET TO BE 18" OFF THE WALL TO THE | | | CENTERLINE. FIG 28. | | | C) HEIGHT 11-4.16.3. | | | D) GRAB BARS 11-4.16 | | | E) FLUSH CONTROLS 11-4.16.5 | | | F) HEIGHT & CLEARANCES 11-4.19.2 | | | G) EXPOSED PIPES & SURFACES 11-4.19.4 | | | H) FAUCEST 11-4.19.5 | | | 3) A DRINKING FOUNTAIN IS REQUIRED IN | | | UNITS 313/315 & AND ONE IN 316 PER TABLE | | | 403.1. SEE SECTION 104.1 ALSO. | | | 4) IN THE REMOVAL OF ANY PART OF A | | | DRAINAGE SYSTEM, DEAD ENDS SHALL BE | | | PROHIBITED. SECTION 704.5 | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|