| Plan Review Stops For Permit 04120586 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-01-19 |
Time |
14:01 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2005-01-19 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2005-01-19 00:00:00 | BUILDING REVIEW PROVISO: | | | 1-INTERIOR FINISH MATERIALS TO BE CLASS | | | | | | "C" MINIMUM. TABLE 803.3 FBC 2001. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-12-16 |
Time |
13:24 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2004-12-16 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2004-12-16 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1-PERMIT APPLICATION IS FOR REMODELING | | | OF 2 BATHROOM ONLY. PLANS CALL FOR | | | ADDITIONAL PARTITIONS REMOVAL TO CREATE | | | CLOSET AND FOR INTERIOR FLOOR TILE AND | | | PAINTING. CLEARLY DESCRIBE SCOPE OF WORK | | | AND VALUE ACCORDINGLY. | | | | | | 2-ARCHITECT TO PROVIDE COMPLETE | | | SPECIFICATIONS FOR TILE TO BE | | | INSTALLED. | | | VERIFY THAT ADDITIONAL TILE LOAD WAS | | | CONSIDEREDFOR STRUCTURAL STABILITY OF | | | THE TYPE OF BUILDING TO BE INSTALLED ON. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC | | | 2001. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-11 |
Time |
10:26 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-01-11 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2005-01-11 00:00:00 | REDLINED NEW BATH GFI'S PER | | | 210.52D,210.11C3 20A #12. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-23 |
Time |
13:04 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-12-23 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2004-12-23 00:00:00 | ********** UNSAT ********** | | | | | | 1)NOTE: PLEASE SEE PERMIT APPLICATION | | | CALLS FOR REMODEL OF 2-BATHS YET SCOPE | | | OF WORK ON PLANS SHOWS NEW ELECTRICAL | | | FOR AN EXISTING? KITCHEN ? | | | | | | PLEASE CLARIFY SCOPE OF WORK AND ADJUST | | | PLANS IF NEEDED. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-01-20 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-01-20 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2005-01-20 00:00:00 | PLANS REVIEWED BY MIKE CARSILLO |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2004-12-30 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2004-12-30 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2004-12-30 00:00:00 | 1) PLEASE PROVIDE INFORMATION ON | | | INTERIOR FINISH OF WALLS AND | | | FLOOR.(PROVISO) | | | | | | | | | M.R.WENNERGREN, A/CAPT | | | WPBFR(561) 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-07 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-07 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2005-01-07 00:00:00 | TO COMM BD#10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-10 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-10 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2004-12-10 00:00:00 | SENT TO "COMM BD#34" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-06 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2005-01-06 |
Time |
14:12 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-06 |
Time |
14:13 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-01-06 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2005-01-06 00:00:00 | FIXTURE CHANGEOUT ONLY. |
|
|