Plan Review Details - Permit 04120584
Plan Review Stops For Permit 04120584
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-02-08 Cont ID  
Sent By jgomez Date 2005-02-08 Time 14:04 Rev Time 2.00
Received By jgomez Date 2005-02-08 Time 14:04 Sent To PC
Notes
2005-02-08 00:00:00BUILDING REVIEW PROVISO:
 (PROVIDE REQUIRED INFORMATION PRIOR TO
 CONSTRUCTION OR INSTALLATION TO AVOID
 CONFLICTS OR DELAYS).
 1- REVISE NAIL SIZE SPECIFIED ON DETAIL
 4/4S1. NEED NAIL THAT PROVIDES 1 3/4"
 MIN. PENETRATION INTO HORIZONTAL FRAMING
 MEMBER. SEE ASTM C926 AND ASTM C1063.
 SEC. 2504.2 FBC 2001.
  
 2- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR METAL ROOF.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-12-22 Cont ID  
Sent By jgomez Date 2004-12-22 Time 08:57 Rev Time 2.50
Received By jgomez Date 2004-12-22 Time 08:57 Sent To PC
Notes
2004-12-22 00:00:00CHECKLIST:
 1-REVISE OWNER INFORMATION NOTED ON
 NOTICE OF COMMENCEMENT TO MATCH PALM
 BEACH COUNTY RECORDS. ALSO. PROVIDE
 LEGIBLE COPIES.
  
 2-UPDATE/REVISE SURVEY. PROPERTY
 DESCRIPTION INFORMATION IS NOT
 COMPLETE.
  
 3-IMPACT FEES PR NUMBER DOESN'T MATCH PR
 NUMBER STAMPED ON PLANS. PROVIDE CORRECT
 IMPACT FEES RECEIPT.
  
 4-REVISE SPECIFICATIONS ON DETAIL 4/4S1.
 NAIL SIZE OF ROOFING NAILS DOESN'T MEET
 THE REQUIREMENTS OF ASTM C1063. NEED
 1 3/4" MIN. NAIL PENETRATION INTO
 FRAMING MEMBER. REVISE AS REQUIRED.
  
 5-PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR:
 A) METAL ROOF.
 B) GARAGE DOOR FOR SIZE SPECIFIED ON
 PLANS.
 C) THERMA TRU ENTRY DOORS AS SPECIFIED
 ON PLANS.
  
 6-REVISE ENERGY CALCULATIONS:
 A) OVERHANG LENGTH AND OVERHANG HEIGHT
 ARE INCORRECT. SEE ATTACHED COPY THAT
 SHOW HOW THESE DIMENSIONS ARE MEASURED.
 B) COMPLETE ALL INFORMATION ON TOP OF
 FORM: ADDRESS, OWNER ETC.
  
 7-SPECIFY HOW ARE STORM SHUTTERS
 INSTALLED ON BEDROOM #2 WINDOW WITHOUT
 CONFLICTING WITH DECORATIVE SHUTTERS.
 SEE FRONT ELEVATION AND REVISE/CLARIFY
 AS REQUIRED. SECTION 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 8-STORM SHUTTERS: A) PROVIDE COMPLETE
 INSTALLATION SCHEDULE AND KEY PLAN. SEE
 ATTACHED SAMPLE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-08-26 Cont ID  
Sent By dpalmer Date 2005-08-26 Time 17:45 Rev Time 0.25
Received By dpalmer Date 2005-08-26 Time 17:19 Sent To  
Notes
2005-08-26 00:00:00REV OK, STAMPED.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-12-15 Cont ID  
Sent By btrobaug Date 2004-12-15 Time 09:45 Rev Time 0.75
Received By btrobaug Date 2004-12-15 Time 09:07 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-08-24 Cont ID  
Sent By adarroug Date 2005-08-24 Time 18:07 Rev Time 0.00
Received By adarroug Date 2005-08-24 Time 18:07 Sent To E
Notes
2005-08-24 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-02-01 Cont ID  
Sent By mjacobs Date 2005-02-01 Time 17:28 Rev Time 0.00
Received By mjacobs Date 2005-02-01 Time 17:28 Sent To B
Notes
2005-02-01 00:00:00TO "JG" DESK/RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-12-15 Cont ID  
Sent By mjacobs Date 2004-12-15 Time 07:43 Rev Time 0.00
Received By mjacobs Date 2004-12-15 Time 07:43 Sent To B
Notes
2004-12-15 00:00:00SENT TO "SF RACK"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-12-13 Cont ID  
Sent By mjacobs Date 2004-12-13 Time 08:08 Rev Time 0.00
Received By mjacobs Date 2004-12-13 Time 08:07 Sent To Z
Notes
2004-12-13 00:00:00SENT TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-12-16 Cont ID  
Sent By pkrauss Date 2004-12-16 Time 07:15 Rev Time 0.35
Received By pkrauss Date 2004-12-16 Time 07:05 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2004-12-18 Cont ID  
Sent By jleech Date 2004-12-18 Time 10:18 Rev Time 25.00
Received By jleech Date 2004-12-18 Time 10:16 Sent To B
Notes
2004-12-18 00:00:00NO RISER DIAGRAM NOT ENOUGH INFORMATION
 TO DO PLUMBING PLAN REVIEW

Review Stop Z ZONING
Rev No 1 Status P Date 2004-12-14 Cont ID  
Sent By mmclean Date 2004-12-14 Time 17:37 Rev Time 0.00
Received By mmclean Date 2004-12-14 Time 17:37 Sent To I
Notes
2004-12-14 00:00:00MUST PULL SEPERATE PERMIT FOR
 POOL/DECK/SCREEN ENCLOSURE