| Plan Review Stops For Permit 04120578 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-12-21 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-12-21 |
Time |
14:07 |
Rev Time |
3.00 |
| Received By |
lsmith |
Date |
2004-12-21 |
Time |
07:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-10 |
Time |
09:52 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-10 |
Time |
08:53 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-01 |
Time |
08:26 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2005-08-01 |
Time |
07:19 |
Sent To |
PC |
|
| Notes |
| 2005-08-01 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THERE IS NO GROUND ROD IN THE | | | GROUNDING ELECTRODE SYSTEM PER | | | 250.52(A)(5). | | | | | | 2} THERE ARE 3 SMALL APPLIANCE CIRCUITS | | | IN THE CALCULATIONS, BUT ONLY ONE ON THE | | | PANEL SCHEDULE. SEE 210.11(C)(3) FOR | | | REQUIREMENTS. | | | | | | 3} THE SMOKE DETECTOR IN THE BATHROOM IS | | | IN VIOLATION OF NFPA-72 ARTICLE 8-1.4.2. | | | | | | 4} THE RECEPTACLE FOR THE "IRRIGATION" | | | SYSTEM MUST BE GFI PROTECTED PER | | | 210.8(A)(3). | | | | | | 5} PLEASE NOTE THAT ONLY 1 THREE WAY | | | SWITCH WAS ADDED TO THE DINING ROOM | | | LIGHT REVISION. | | | | | | 6} THE LAST REVISION DATE IN THE TITLE | | | BLOCK IS 8-21-04. PLEASE CORRECT SAME. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-12-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-12-15 |
Time |
10:22 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-12-15 |
Time |
10:12 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-04 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-04 |
Time |
15:54 |
Sent To |
E |
|
| Notes |
| 2005-08-04 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-29 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-29 |
Time |
15:22 |
Sent To |
E |
|
| Notes |
| 2005-07-29 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-12-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-15 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-15 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2004-12-15 00:00:00 | SENT TO "SF RACK." |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-13 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-13 |
Time |
08:10 |
Sent To |
Z |
|
| Notes |
| 2004-12-13 00:00:00 | SENT TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-12-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-16 |
Time |
07:34 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-12-16 |
Time |
07:21 |
Sent To |
P |
|
| Notes |
| 2004-12-16 00:00:00 | PROVISO: | | | RETURN AIR FROM THE MASTER BEDROOM SHALL | | | BE A MINIMUM OF 12", EQUAL TO THE SUPPLY | | | AIR TO THE ENTIRE MASTER SUITE.2001 | | | FBC(M)601.4 AND EXCEPTION #3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-12-18 |
Time |
10:12 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2004-12-18 |
Time |
10:12 |
Sent To |
B |
|
| Notes |
| 2004-12-18 00:00:00 | NO PLUMBING RISER NOT ENOUGH INFORMATION | | | TO DO PLUMBING PLAN REVIEW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-12-14 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-12-14 |
Time |
17:30 |
Sent To |
I |
|
| Notes |
| 2004-12-14 00:00:00 | MUST PULL SEPERATE PERMIT FOR | | | POOL/DECK/SCREEN ENCLOSURE |
|
|