Plan Review Details - Permit 04120578
Plan Review Stops For Permit 04120578
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-12-21 Cont ID  
Sent By lsmith Date 2004-12-21 Time 14:07 Rev Time 3.00
Received By lsmith Date 2004-12-21 Time 07:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-08-10 Cont ID  
Sent By btrobaug Date 2005-08-10 Time 09:52 Rev Time 0.50
Received By btrobaug Date 2005-08-10 Time 08:53 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-08-01 Cont ID  
Sent By btrobaug Date 2005-08-01 Time 08:26 Rev Time 0.75
Received By btrobaug Date 2005-08-01 Time 07:19 Sent To PC
Notes
2005-08-01 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THERE IS NO GROUND ROD IN THE
 GROUNDING ELECTRODE SYSTEM PER
 250.52(A)(5).
  
 2} THERE ARE 3 SMALL APPLIANCE CIRCUITS
 IN THE CALCULATIONS, BUT ONLY ONE ON THE
 PANEL SCHEDULE. SEE 210.11(C)(3) FOR
 REQUIREMENTS.
  
 3} THE SMOKE DETECTOR IN THE BATHROOM IS
 IN VIOLATION OF NFPA-72 ARTICLE 8-1.4.2.
  
 4} THE RECEPTACLE FOR THE "IRRIGATION"
 SYSTEM MUST BE GFI PROTECTED PER
 210.8(A)(3).
  
 5} PLEASE NOTE THAT ONLY 1 THREE WAY
 SWITCH WAS ADDED TO THE DINING ROOM
 LIGHT REVISION.
  
 6} THE LAST REVISION DATE IN THE TITLE
 BLOCK IS 8-21-04. PLEASE CORRECT SAME.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-12-15 Cont ID  
Sent By btrobaug Date 2004-12-15 Time 10:22 Rev Time 0.75
Received By btrobaug Date 2004-12-15 Time 10:12 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-08-04 Cont ID  
Sent By adarroug Date 2005-08-04 Time 15:54 Rev Time 0.00
Received By adarroug Date 2005-08-04 Time 15:54 Sent To E
Notes
2005-08-04 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-07-29 Cont ID  
Sent By adarroug Date 2005-07-29 Time 15:22 Rev Time 0.00
Received By adarroug Date 2005-07-29 Time 15:22 Sent To E
Notes
2005-07-29 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-12-15 Cont ID  
Sent By mjacobs Date 2004-12-15 Time 07:49 Rev Time 0.00
Received By mjacobs Date 2004-12-15 Time 07:49 Sent To  
Notes
2004-12-15 00:00:00SENT TO "SF RACK."

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-12-13 Cont ID  
Sent By mjacobs Date 2004-12-13 Time 08:10 Rev Time 0.00
Received By mjacobs Date 2004-12-13 Time 08:10 Sent To Z
Notes
2004-12-13 00:00:00SENT TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-12-16 Cont ID  
Sent By pkrauss Date 2004-12-16 Time 07:34 Rev Time 0.35
Received By pkrauss Date 2004-12-16 Time 07:21 Sent To P
Notes
2004-12-16 00:00:00PROVISO:
 RETURN AIR FROM THE MASTER BEDROOM SHALL
 BE A MINIMUM OF 12", EQUAL TO THE SUPPLY
 AIR TO THE ENTIRE MASTER SUITE.2001
 FBC(M)601.4 AND EXCEPTION #3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 1 Status N Date 2004-12-18 Cont ID  
Sent By jleech Date 2004-12-18 Time 10:12 Rev Time 0.25
Received By jleech Date 2004-12-18 Time 10:12 Sent To B
Notes
2004-12-18 00:00:00NO PLUMBING RISER NOT ENOUGH INFORMATION
 TO DO PLUMBING PLAN REVIEW

Review Stop Z ZONING
Rev No 1 Status P Date 2004-12-14 Cont ID  
Sent By mmclean Date 2004-12-14 Time 17:30 Rev Time 0.00
Received By mmclean Date 2004-12-14 Time 17:30 Sent To I
Notes
2004-12-14 00:00:00MUST PULL SEPERATE PERMIT FOR
 POOL/DECK/SCREEN ENCLOSURE