Plan Review Details - Permit 04120533
Plan Review Stops For Permit 04120533
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2005-05-24 Cont ID  
Sent By jhiggins Date 2005-05-24 Time 10:58 Rev Time 0.00
Received By jleahy Date 2005-04-15 Time 10:57 Sent To  
Notes
2004-12-17 00:00:00EXTENSIONS ADDED

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-04-19 Cont ID  
Sent By jwitmer Date 2005-04-19 Time 09:37 Rev Time 0.75
Received By jwitmer Date 2005-04-19 Time 08:59 Sent To PC
Notes
2005-04-19 00:00:004-19-05 REVISION OF 4-14-05 RELOCATION
 OF RESTROOMS AND WALL INFILL.OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-03-10 Cont ID  
Sent By jwitmer Date 2005-03-10 Time 12:33 Rev Time 0.55
Received By jwitmer Date 2005-03-10 Time 12:33 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-03-09 Cont ID  
Sent By jwitmer Date 2005-03-09 Time 10:45 Rev Time 0.33
Received By jwitmer Date 2005-03-09 Time 10:43 Sent To PC
Notes
2005-03-09 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04120533
 ADD: 4912 S DIXIE
 CONT: ADAMS PLASTERING
 TEL: (561)793-3083
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 3RD REVIEW
 ACTION: DENIED
  
 1) FIRE DISTRICT NO TYPE VI CONSTRUCTION
 SEE AREA OF OLD GARAGE DOOR NEW WALL
 AREA.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-02-18 Cont ID  
Sent By jwitmer Date 2005-02-18 Time 08:03 Rev Time 2.22
Received By jwitmer Date 2005-02-18 Time 08:03 Sent To  
Notes
2005-02-18 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04120533
 ADD: 4912 S DIXIE HWY
 CONT:ADAM PLASTERING
 TEL: (561)248-5400
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 2NDREVIEW
 ACTION: DENIED
  
 1) COMMENT #3 FROM THE PREVIOUS REVIEW:
 FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) NEW EXTERIOR DOOR@ OLD GARAGE DOOR.
 PRODUCT APPROVALS SUBMITTED WITH PERMIT
 APPLICATION AFTER OCTOBER 1, 2003 ARE
 REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 2) DEALS WITH COMMENT #7 FROM THE
 PREVIOUS REVIEW: THE AREA LEFT OF THE
 STAIRWELL, PLANS INDICATE INFILL OF OLD
 GARAGE DOOR WITH WOOD FRAME. PLANS ALSO
 INDICATE THE STRUCTURE BEING MASONARY,
 SINCE THE STRUCTURE IS LOCATED IN A FIRE
 DISTRICT, THE EXTERIOR WALLS CAN NOT BE
 OF TYPE VI ( COMBUSTIBLE) CONSTRUCTION.
 SEE F102.1*.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-01-11 Cont ID  
Sent By jwitmer Date 2005-01-11 Time 10:51 Rev Time 3.00
Received By jwitmer Date 2005-01-11 Time 10:51 Sent To  
Notes
2005-01-11 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04120533
 ADD: 4912 S DIXIE HWY
 CONT: ADAM PLASTERING
 TEL: (561248-5400
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2)FL BLD CODE 104.2.1.2*
 ADDITIONAL INFORMATION REQUIRED,
 2A) 704.3 INDICATE, TENANT SEPERATION
 PROVIDE U.L. LISTING OR GYPSUM
 ASSOCIATION NUMBER.
 2B)TABLE 704.1 OCCUPANCY SEPERATION,
 PROVIDE INFORMATION INDICATING
 COMPLIANCE.
  
 3)FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) WINDOWS
 B) EXTERIOR DOORS
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 4) 2001 FL BLD CODE, 1005.4:
 PROVIDE EMERGENCY EGRESS WINDOWS IN
 SLEEPING ROOMS WITH A MINIMUM NET CLEAR
 OPENING HEIGTH OF 24" AND NET CLEAR
 OPENING WIDTH OF 20" AND A NET CLEAR
 OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR
 OPENINGS ARE PERMITTED TO HAVE A NET
 CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH
 SHALL NOT BE MORE THAN 44 " ABOVE THE
 FINISH FLOOR.
  
 5) NOTE THE GLAZING BEING REPLACED ON
 EXISTING BUILDINGS WILL NEED TO MEET THE
  
 REQUIREMENTS FOR LARGE MISSLE IMPACT
 SEE
 3401.7.2.4. ONLY IF THIS WAS A 1 OR 2
 FAMILY DWELLING IS THERE A 25%
 EXCEPTION.
  
 6) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 7) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 WHAT IS THE AREA JUST LEFT ON THE
 STAIRWELL FOR THE FIRST FLOOR? IS THIS
 INTERIOR / EXTERIOR? WHAT WILL THIS AREA
 BE USED FOR?
  
 8) ELECTRIC PLAN INDICATES OFFICE "A"
 INDICATES A ON 2 EAST WALLS BUT NO
 REFRENCE TO WHAT THIS IS FOR? OFFICE
 "B" ALSO HAS A SIMILAR SITUATION?
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-05-24 Cont ID  
Sent By jleahy Date 2005-05-24 Time 10:52 Rev Time 0.45
Received By jleahy Date 2005-05-24 Time 10:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-03-08 Cont ID  
Sent By dpalmer Date 2005-03-08 Time 15:50 Rev Time 0.50
Received By dpalmer Date 2005-03-08 Time 15:50 Sent To B
Notes
2005-03-08 00:00:00** NOTES REDLINED **
  
 KITCHEN COUNTERSPACE RECEPTS PER 210.8A6
 SIGN CIRCUIT IN UNIT #3, 600.5
 MIN OF 1.5KW FOR SMALL APPL CIRCUITS,
 PANEL SCHEDULE INDICATES 360, AND 180
 VA.???

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-02-08 Cont ID  
Sent By dpalmer Date 2005-02-08 Time 18:27 Rev Time 1.00
Received By dpalmer Date 2005-02-08 Time 18:15 Sent To  
Notes
2005-02-08 00:00:00************* UNSAT 2ND REVIEW
 *********
  
 PLEASE SEE NOTES FROM FIRST REVIEW, SOME
 OF WHICH STILL NEED TO BE ADDRESSED AND
 NEW NOTES DUE TO CHANGES IN PLANS.
  
 1)NOTE: NOTE #1, NO, PLEASE SHOW ALL
 CIRCUITING ON PLANS AND CORRELATE WITH
 SUBMITTED PANEL SCHEDULE.
 CIRCUITING MISSING FROM COMMERCIAL
 TENANTS SPACES AND RESIDENTIAL UNIT IS
 COMPLETELY BLANK? 215.5
  
 2)NOTE: NOTE #2 NO, PLEASE SEE 700.12E
 FOR CIRCUITING OF EM/EXT LTS.
  
 3)NOTE: NOTE #3 NO,PLEASE SEE SOME
 TENANT SPACES SHOWN AS MERCHANTILE DO
 NOT INDICATE REQUIRED SIGN CIRCUIT ON
 PLANS PER 600.5.
 PLEASE ALSO SEE 210.62,220.12, SHOW
 WINDOW RECEPTS ARE NOT PERMITTED TO HAVE
 OTHER GENERAL USE RECEPTS ON THE SAME
 CIRCUIT.
  
 4)NOTE: NOTE#4 NO, PLEASE SEE A RISER IS
 SHOWN, HOWEVER NO WIRE SIZES ARE
 INDICATED ON PANEL SCHEDULES FOR BRANCH
 CIRCUIT WIRING???
 PLEASE SEE PANEL SCHEDULES DO NOT
 INDICATE ANY OVERCURRENT PROTECTION
 SIZES FOR BRANCH CIRCUITS?
 240.4,310.16,215.5
 PLEASE ALSO SEE PANEL SCHEDULE FOR
 RESIDENTIAL UNIT ONLY SHOWS A/C UNIT,
 YET LOAD CALCULATION DO NOT CORRELATE?
 215.5
 PLEASE SEE GROUNDING ELECTRODE SYSTEM TO
 BE SHOWN PER 250.50. CWP?
 PLEASE VERIFY WHY RESIDENTIAL UNIT WHICH
 IS PART OF THIS BLDG, IS SHOWN WITH A
 SEPARATE SERVICE? PLEASE SEE 230.2 FOR
 ADDITIONAL SERVICES PERMITTED.
  
 4)NOTE: NOTE #4, NO, PLEASE SEE 2002
 NEC.
  
 **************************************
 PLEASE SEE NEW COMMENTS DUE TO CHANGES
 IN PLANS.
  
 1)NOTE: PLEASE SEE COND UNITS ARE FOR
 EACH SPACE IS NOW SHOWN INSIDE ONE OF
 THE TENANT SPACES STORAGE RMS?
 THIS IS NOT PERMITTED AND PLEASE SEE ANY
 MECHANICAL COMMENTS FOR LOCATION OF
 UNITS ALSO.
  
 2)NOTE: PLEASE SEE RESIDENTIAL LOAD
 CALCS INDICATE A WASHER AND A LAUNDRY
 CIRCUIT? PLEASE VERIFY. PLEASE ALSO SEE
 220.16 FOR A MIN OF 1500VA
  
 3)NOTE: PLEASE SEE 220.19 FOR MIN LOAD
 FOR RANGES TO BE FIGURED IN A
 RESIDENTIAL UNIT.
  
 4)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS
 ARE TO BE SHOWN AT 125%.
 PLEASE ALSO SEE 220.12 FOR SHOW WINDOW
 LOADS.
 215.3,230.42, ETC
  
 5)NOTE: PLEASE SHOW ALL MIN REQUIRED FOR
 RESIDENTIAL UNIT, RECEPTS,LTS, SWITCHES,
 SD'S ETCPER 2002 NEC
 210.52,210.70,210.11, ETC
 NFPA-72 8-1.4.1.6.2 AND 8-1.4.2 FOR SD
 PLACEMENT.
  
 6)NOTE: PLEASE SUBMIT TWO COMPLETE SETS
 OF PLANS FOR REVIEW AND STAMPING.
 PLEASE SEE ONE SET HAD AN E-1 AND THE
 OTHER HAD AN E-2?
  
 7)NOTE: PLEASE SEE PLANS NOW INDICATE
 BEING DRAWN BY BRAUN ELECTRIC, HOWEVER
 PLANS ARE STILL SHOWN AS SIGNED AND
 SEALED BY GORDON BUCK( STRUCTUAL
 ENGINEER)? PLEASE SEEPLANS ARE TO HAVE
 THE PRINTED NAME AND SIGNATURE OF PERSON
 RESPONSIBLE FOR PLANS. FBC 104.2.1
 PLEASE SEE ONE SET OF ORIGINAL PLANS AND
 THE ONE SET SUBMITTED FOR THIS REVIEW IS
 BEING RETAINED AND SHALL BE TURNED INTO
 THE FBPE'S FOR REVIEW.
 PLEASE ALSO SEE COPY OF FS. 553.80(2)(B)
 WHICH IS NOW ATTACHED AND GIVEN AS
 NOTICE AT THIS TIME. THE WILL BE
 ACCESSED IF PLANS COME BACK WITH ANY OF
 THE SAME COMMENTS NOT ADDRESSED FOR
 THIRD REVIEW.
  
 8)NOTE:PLEASE SEE FBC 104.6.5 FOR
 VALUATION OF SCOPE OF WORK INDICATED ON
 PLANS.
 PLEASEPROVIDE A COPY OF CONTRACTS FOR
 WORK PROPOSED. VALUE SHOWN AS
 $12,800.00
  
 PLEASE REMOVEV ALL OLD/VOIDED SHEETS
 FROM SETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. PLEASE SEE BLDG REVIEW
 COMMENTS ON FIRST REVIEW.
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-12-27 Cont ID  
Sent By dpalmer Date 2004-12-27 Time 07:36 Rev Time 0.50
Received By dpalmer Date 2004-12-27 Time 07:36 Sent To  
Notes
2004-12-27 00:00:00************* UNSAT ****************
  
 1)NOTE: PLEASE PROVIDE ALL CIRCUITING ON
 PLANS AND CORRELATE WITH PANEL SCHEDULES
 TO BE SUBMITTED.
 215.5
  
 2)NOTE: PLEASE SEE 2002 NEC FOR MIN
 CIRCUITING REQUIRED.
 700.12E
  
 3)NOTE: PLEASE SEE 600.5, 210.62, 220.12
 FOR MIN REQUIRED.
  
 4)NOTE: PLEASE SUBMIT A COMPLETED RISER
 DIAGRAM SHOWING NEW SERVICE. PLEASE SEE
 MAINS ARE TO BE GROUPED. 230.72.
 SHOW CONDUCTOR SIZES, CONDUITS,
 GROUNDING FOR NEW SERVICE. ETC.
 215.5,310.16,240.4,250.50 ETC.
  
  
 5)NOTE: PLANS APPEAR TO SHOW MIXED USE
 OCCP. PLEASE ADJUST ELECTRICAL PLANS.
 PLEASE SEE 2002 NEC FOR ALL MIN REQUIRED
 FOR RESIDENTIAL.
  
 PLEASE NOTE: DUE TO PLANS NOT BEING
 COMPLETE AT THIS TIME, A COMPLETE REVIEW
 FOR CODE COMPLIANCE CAN NOT BE DONE.
  
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY HAVE AN
 AFFECT ON ELECTRICAL PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2005-02-25 Cont ID  
Sent By mcarsill Date 2005-02-25 Time 17:04 Rev Time 0.00
Received By mcarsill Date 2005-02-25 Time 17:04 Sent To  
Notes
2005-02-25 00:00:00SEE PREVIOUS NOTES FOR PLAN REVIEW.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-02-23 Cont ID  
Sent By mcarsill Date 2004-12-27 Time 14:05 Rev Time 0.00
Received By mcarsill Date 2005-02-25 Time 17:02 Sent To  
Notes
2005-02-23 00:00:001. NO SMOKE DETECTORS SHOWN IN
 APARTMENT. ELECTRIC POWERED
 SMOKE DETECTORS ARE REQUIRED INSIDE
 AND OUTSIDE OF EVERY SLEEPING ROOM.
  
 2. BUILDING ADDRESS REQUIRED ON
 PROPER ELEVATION. A MINIMUM OF 6"
 HIGH NUMBERS ARE REQUIRED.
  
 3. NO HANDRAIL (S) SHOWN FOR
 INTERIOR STAIR.
  
 4. THE FIRST FLOOR LEVEL MUST
 MEET ALL OF THE CODE REQUIREMENTS
 FOR MERCANTILE OCCUPANCIES. PROPER
 TENANT SEPARATIONS, OPENING
 PROTECTIVES, PORTABLE FIRE
 EXTINGUISHERS, EMERGENCY LIGHTS
 AND EXIT SIGNS ARE REQUIRED.
 PROPER DOOR LOCKS ARE REQUIRED.
 THE FIRST FLOOR IMPROVEMENTS ARE
 SUBJECT TO FIELD INSPECTION.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910
  
 APPROVED PROVISO:
2004-12-27 00:00:001. BUILDING ADDRESS REQUIRED ON
 PROPER ELEVATION. A MINIMUM OF 6"
 HIGH NUMBERS ARE REQUIRED.
  
 2. PLEASE INDICATE ALL HORIZONTAL
 AND VERTICAL FIRE SEPARATIONS BETWEEN
 DIFFERENT TENANTS AND DIFFERENT
 OCCUPANCY TYPES. ALSO PLEASE
 SHOW REQUIRED OPENING PROTECTIVES.
  
 3. IT APPEARS THAT AN EXIT SIGN FOR
 OFFICE/RETAIL B MAY BE LOCATED INFRONT
 OF A GARAGE DOOR.
  
 4. PLEASE INDICATE INTERIOR FINISH
 CLASSIFICATIONS FOR ALL WALLS AND
 CEILINGS.
  
 5. HOW IS STAIR SEPARATED FROM
 REMAINDER OF BUILDING.
  
 6. NO DOOR SCHEDULE PROVIDED.
  
 7. NO FIRE SAFING DETAILS PROVIDED.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-05-20 Cont ID  
Sent By adarroug Date 2005-05-20 Time 10:48 Rev Time 0.00
Received By adarroug Date 2005-05-20 Time 10:48 Sent To E
Notes
2005-05-20 00:00:00TO "DPALMER" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-04-18 Cont ID  
Sent By adarroug Date 2005-04-18 Time 14:38 Rev Time 0.00
Received By adarroug Date 2005-04-18 Time 14:38 Sent To B
Notes
2005-04-18 00:00:00TO "JWITMER" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-03-08 Cont ID  
Sent By adarroug Date 2005-03-08 Time 15:29 Rev Time 0.00
Received By adarroug Date 2005-03-08 Time 15:29 Sent To E
Notes
2005-03-08 00:00:00TO "DP" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-02-25 Cont ID  
Sent By adarroug Date 2005-02-25 Time 11:02 Rev Time 0.00
Received By adarroug Date 2005-02-25 Time 11:02 Sent To FIRE
Notes
2005-02-25 00:00:00TO "F" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-02-03 Cont ID  
Sent By adarroug Date 2005-02-03 Time 11:27 Rev Time 0.00
Received By adarroug Date 2005-02-03 Time 11:27 Sent To  
Notes
2005-02-03 00:00:00TO COMM BOARD/#13

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By mjacobs Date 2005-01-11 Time 15:24 Rev Time 0.00
Received By jwitmer Date 2004-12-10 Time 08:57 Sent To  
Notes
2004-12-10 00:00:00SENT TO COMM BD#42

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2005-02-25 Cont ID  
Sent By pkrauss Date 2005-02-25 Time 07:12 Rev Time 0.20
Received By pkrauss Date 2005-02-23 Time 09:53 Sent To  
Notes
2005-02-23 00:00:00MRS. DARBY 799-3576 676-6841, CALL IF
 PROBLEMS OR QUESTIONS.
  
 NO MECHANICAL PLANS OR CONTRACTOR
 INDICATED ON PERMIT APPLICATION.PLEASE
 PROVIDE PLANS WITH MECHANICAL PERMIT
 APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-12-31 Cont ID  
Sent By pkrauss Date 2004-12-31 Time 10:16 Rev Time 0.30
Received By pkrauss Date 2004-12-31 Time 10:16 Sent To  
Notes
2004-12-31 00:00:00DENIED:
 PLAN SHEET 2 OF 6 INDICATES A "NEW
 STACKABLE WASHER/DRYER".PROVIDE
 INFORMATION ON THE EXHAUST FROM THE
 DRYER.INDICATE DUCT SIZE, MATERIAL,
 LAYOUT AND TERMINATION.PROVIDE
 INFORMATION ON PENETRATIONS THROUGH ANY
 RATED WALLS, PARTITIONS OR
 CEILING/ROOF.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-02-19 Cont ID  
Sent By jleech Date 2005-02-19 Time 07:08 Rev Time 0.50
Received By jleech Date 2005-02-19 Time 07:08 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-01-10 Cont ID  
Sent By jleech Date 2005-01-10 Time 09:49 Rev Time 1.00
Received By jleech Date 2005-01-10 Time 09:49 Sent To  
Notes
2005-01-10 00:00:00DENIED;
 1.NOT ENOUGH INFORMATION TO DO A
 PLUMBING REVIEW. PLEASE SHOW RISER
 DIAGRAMS FOR SANITARY AND WATER. SHOW
 HOW RAIN IS DISCHARGED FROM FLAT ROOF
 AREA.
 2.DRINKING FOUNTAINS ARE REQUIRED TO
 MEET MINIMUM PLUMBING FACILITIES. SEE
 FBC PLUMGBING TABLE 403.1.
 3.OFFICE SPACE C & D. BATHROOM
 FACILITIES SHALL BE EATHER SEPARATE OR
 PUBLIC CUSTOMER FACILITIES. SEC.403.5
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status P Date 2005-01-12 Cont ID  
Sent By mmclean Date 2005-01-12 Time 10:20 Rev Time 0.00
Received By mmclean Date 2005-01-12 Time 10:20 Sent To  
Notes
2005-01-12 00:00:00PROVISO: NEED TO APPLY FOR A RENTAL
 OCCUPATIONAL LICENSE BEFORE BUIDLING IS
 C.O.