| Plan Review Stops For Permit 04120533 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
jhiggins |
Date |
2005-05-24 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2005-04-15 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2004-12-17 00:00:00 | EXTENSIONS ADDED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-04-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-04-19 |
Time |
09:37 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2005-04-19 |
Time |
08:59 |
Sent To |
PC |
|
| Notes |
| 2005-04-19 00:00:00 | 4-19-05 REVISION OF 4-14-05 RELOCATION | | | OF RESTROOMS AND WALL INFILL.OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-03-10 |
Time |
12:33 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-03-10 |
Time |
12:33 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-03-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-03-09 |
Time |
10:45 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-03-09 |
Time |
10:43 |
Sent To |
PC |
|
| Notes |
| 2005-03-09 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04120533 | | | ADD: 4912 S DIXIE | | | CONT: ADAMS PLASTERING | | | TEL: (561)793-3083 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | 1) FIRE DISTRICT NO TYPE VI CONSTRUCTION | | | SEE AREA OF OLD GARAGE DOOR NEW WALL | | | AREA. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-02-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-02-18 |
Time |
08:03 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-02-18 |
Time |
08:03 |
Sent To |
|
|
| Notes |
| 2005-02-18 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04120533 | | | ADD: 4912 S DIXIE HWY | | | CONT:ADAM PLASTERING | | | TEL: (561)248-5400 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | 1) COMMENT #3 FROM THE PREVIOUS REVIEW: | | | FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) NEW EXTERIOR DOOR@ OLD GARAGE DOOR. | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT | | | APPLICATION AFTER OCTOBER 1, 2003 ARE | | | REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 2) DEALS WITH COMMENT #7 FROM THE | | | PREVIOUS REVIEW: THE AREA LEFT OF THE | | | STAIRWELL, PLANS INDICATE INFILL OF OLD | | | GARAGE DOOR WITH WOOD FRAME. PLANS ALSO | | | INDICATE THE STRUCTURE BEING MASONARY, | | | SINCE THE STRUCTURE IS LOCATED IN A FIRE | | | DISTRICT, THE EXTERIOR WALLS CAN NOT BE | | | OF TYPE VI ( COMBUSTIBLE) CONSTRUCTION. | | | SEE F102.1*. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-01-11 |
Time |
10:51 |
Rev Time |
3.00 |
| Received By |
jwitmer |
Date |
2005-01-11 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2005-01-11 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04120533 | | | ADD: 4912 S DIXIE HWY | | | CONT: ADAM PLASTERING | | | TEL: (561248-5400 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)FL BLD CODE 104.2.1.2* | | | ADDITIONAL INFORMATION REQUIRED, | | | 2A) 704.3 INDICATE, TENANT SEPERATION | | | PROVIDE U.L. LISTING OR GYPSUM | | | ASSOCIATION NUMBER. | | | 2B)TABLE 704.1 OCCUPANCY SEPERATION, | | | PROVIDE INFORMATION INDICATING | | | COMPLIANCE. | | | | | | 3)FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS | | | B) EXTERIOR DOORS | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 4) 2001 FL BLD CODE, 1005.4: | | | PROVIDE EMERGENCY EGRESS WINDOWS IN | | | SLEEPING ROOMS WITH A MINIMUM NET CLEAR | | | OPENING HEIGTH OF 24" AND NET CLEAR | | | OPENING WIDTH OF 20" AND A NET CLEAR | | | OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR | | | OPENINGS ARE PERMITTED TO HAVE A NET | | | CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH | | | SHALL NOT BE MORE THAN 44 " ABOVE THE | | | FINISH FLOOR. | | | | | | 5) NOTE THE GLAZING BEING REPLACED ON | | | EXISTING BUILDINGS WILL NEED TO MEET THE | | | | | | REQUIREMENTS FOR LARGE MISSLE IMPACT | | | SEE | | | 3401.7.2.4. ONLY IF THIS WAS A 1 OR 2 | | | FAMILY DWELLING IS THERE A 25% | | | EXCEPTION. | | | | | | 6) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 7) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | WHAT IS THE AREA JUST LEFT ON THE | | | STAIRWELL FOR THE FIRST FLOOR? IS THIS | | | INTERIOR / EXTERIOR? WHAT WILL THIS AREA | | | BE USED FOR? | | | | | | 8) ELECTRIC PLAN INDICATES OFFICE "A" | | | INDICATES A ON 2 EAST WALLS BUT NO | | | REFRENCE TO WHAT THIS IS FOR? OFFICE | | | "B" ALSO HAS A SIMILAR SITUATION? | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-05-24 |
Time |
10:52 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2005-05-24 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-08 |
Time |
15:50 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-03-08 |
Time |
15:50 |
Sent To |
B |
|
| Notes |
| 2005-03-08 00:00:00 | ** NOTES REDLINED ** | | | | | | KITCHEN COUNTERSPACE RECEPTS PER 210.8A6 | | | SIGN CIRCUIT IN UNIT #3, 600.5 | | | MIN OF 1.5KW FOR SMALL APPL CIRCUITS, | | | PANEL SCHEDULE INDICATES 360, AND 180 | | | VA.??? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-02-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-08 |
Time |
18:27 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-02-08 |
Time |
18:15 |
Sent To |
|
|
| Notes |
| 2005-02-08 00:00:00 | ************* UNSAT 2ND REVIEW | | | ********* | | | | | | PLEASE SEE NOTES FROM FIRST REVIEW, SOME | | | OF WHICH STILL NEED TO BE ADDRESSED AND | | | NEW NOTES DUE TO CHANGES IN PLANS. | | | | | | 1)NOTE: NOTE #1, NO, PLEASE SHOW ALL | | | CIRCUITING ON PLANS AND CORRELATE WITH | | | SUBMITTED PANEL SCHEDULE. | | | CIRCUITING MISSING FROM COMMERCIAL | | | TENANTS SPACES AND RESIDENTIAL UNIT IS | | | COMPLETELY BLANK? 215.5 | | | | | | 2)NOTE: NOTE #2 NO, PLEASE SEE 700.12E | | | FOR CIRCUITING OF EM/EXT LTS. | | | | | | 3)NOTE: NOTE #3 NO,PLEASE SEE SOME | | | TENANT SPACES SHOWN AS MERCHANTILE DO | | | NOT INDICATE REQUIRED SIGN CIRCUIT ON | | | PLANS PER 600.5. | | | PLEASE ALSO SEE 210.62,220.12, SHOW | | | WINDOW RECEPTS ARE NOT PERMITTED TO HAVE | | | OTHER GENERAL USE RECEPTS ON THE SAME | | | CIRCUIT. | | | | | | 4)NOTE: NOTE#4 NO, PLEASE SEE A RISER IS | | | SHOWN, HOWEVER NO WIRE SIZES ARE | | | INDICATED ON PANEL SCHEDULES FOR BRANCH | | | CIRCUIT WIRING??? | | | PLEASE SEE PANEL SCHEDULES DO NOT | | | INDICATE ANY OVERCURRENT PROTECTION | | | SIZES FOR BRANCH CIRCUITS? | | | 240.4,310.16,215.5 | | | PLEASE ALSO SEE PANEL SCHEDULE FOR | | | RESIDENTIAL UNIT ONLY SHOWS A/C UNIT, | | | YET LOAD CALCULATION DO NOT CORRELATE? | | | 215.5 | | | PLEASE SEE GROUNDING ELECTRODE SYSTEM TO | | | BE SHOWN PER 250.50. CWP? | | | PLEASE VERIFY WHY RESIDENTIAL UNIT WHICH | | | IS PART OF THIS BLDG, IS SHOWN WITH A | | | SEPARATE SERVICE? PLEASE SEE 230.2 FOR | | | ADDITIONAL SERVICES PERMITTED. | | | | | | 4)NOTE: NOTE #4, NO, PLEASE SEE 2002 | | | NEC. | | | | | | ************************************** | | | PLEASE SEE NEW COMMENTS DUE TO CHANGES | | | IN PLANS. | | | | | | 1)NOTE: PLEASE SEE COND UNITS ARE FOR | | | EACH SPACE IS NOW SHOWN INSIDE ONE OF | | | THE TENANT SPACES STORAGE RMS? | | | THIS IS NOT PERMITTED AND PLEASE SEE ANY | | | MECHANICAL COMMENTS FOR LOCATION OF | | | UNITS ALSO. | | | | | | 2)NOTE: PLEASE SEE RESIDENTIAL LOAD | | | CALCS INDICATE A WASHER AND A LAUNDRY | | | CIRCUIT? PLEASE VERIFY. PLEASE ALSO SEE | | | 220.16 FOR A MIN OF 1500VA | | | | | | 3)NOTE: PLEASE SEE 220.19 FOR MIN LOAD | | | FOR RANGES TO BE FIGURED IN A | | | RESIDENTIAL UNIT. | | | | | | 4)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | ARE TO BE SHOWN AT 125%. | | | PLEASE ALSO SEE 220.12 FOR SHOW WINDOW | | | LOADS. | | | 215.3,230.42, ETC | | | | | | 5)NOTE: PLEASE SHOW ALL MIN REQUIRED FOR | | | RESIDENTIAL UNIT, RECEPTS,LTS, SWITCHES, | | | SD'S ETCPER 2002 NEC | | | 210.52,210.70,210.11, ETC | | | NFPA-72 8-1.4.1.6.2 AND 8-1.4.2 FOR SD | | | PLACEMENT. | | | | | | 6)NOTE: PLEASE SUBMIT TWO COMPLETE SETS | | | OF PLANS FOR REVIEW AND STAMPING. | | | PLEASE SEE ONE SET HAD AN E-1 AND THE | | | OTHER HAD AN E-2? | | | | | | 7)NOTE: PLEASE SEE PLANS NOW INDICATE | | | BEING DRAWN BY BRAUN ELECTRIC, HOWEVER | | | PLANS ARE STILL SHOWN AS SIGNED AND | | | SEALED BY GORDON BUCK( STRUCTUAL | | | ENGINEER)? PLEASE SEEPLANS ARE TO HAVE | | | THE PRINTED NAME AND SIGNATURE OF PERSON | | | RESPONSIBLE FOR PLANS. FBC 104.2.1 | | | PLEASE SEE ONE SET OF ORIGINAL PLANS AND | | | THE ONE SET SUBMITTED FOR THIS REVIEW IS | | | BEING RETAINED AND SHALL BE TURNED INTO | | | THE FBPE'S FOR REVIEW. | | | PLEASE ALSO SEE COPY OF FS. 553.80(2)(B) | | | WHICH IS NOW ATTACHED AND GIVEN AS | | | NOTICE AT THIS TIME. THE WILL BE | | | ACCESSED IF PLANS COME BACK WITH ANY OF | | | THE SAME COMMENTS NOT ADDRESSED FOR | | | THIRD REVIEW. | | | | | | 8)NOTE:PLEASE SEE FBC 104.6.5 FOR | | | VALUATION OF SCOPE OF WORK INDICATED ON | | | PLANS. | | | PLEASEPROVIDE A COPY OF CONTRACTS FOR | | | WORK PROPOSED. VALUE SHOWN AS | | | $12,800.00 | | | | | | PLEASE REMOVEV ALL OLD/VOIDED SHEETS | | | FROM SETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. PLEASE SEE BLDG REVIEW | | | COMMENTS ON FIRST REVIEW. | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-12-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-27 |
Time |
07:36 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-12-27 |
Time |
07:36 |
Sent To |
|
|
| Notes |
| 2004-12-27 00:00:00 | ************* UNSAT **************** | | | | | | 1)NOTE: PLEASE PROVIDE ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH PANEL SCHEDULES | | | TO BE SUBMITTED. | | | 215.5 | | | | | | 2)NOTE: PLEASE SEE 2002 NEC FOR MIN | | | CIRCUITING REQUIRED. | | | 700.12E | | | | | | 3)NOTE: PLEASE SEE 600.5, 210.62, 220.12 | | | FOR MIN REQUIRED. | | | | | | 4)NOTE: PLEASE SUBMIT A COMPLETED RISER | | | DIAGRAM SHOWING NEW SERVICE. PLEASE SEE | | | MAINS ARE TO BE GROUPED. 230.72. | | | SHOW CONDUCTOR SIZES, CONDUITS, | | | GROUNDING FOR NEW SERVICE. ETC. | | | 215.5,310.16,240.4,250.50 ETC. | | | | | | | | | 5)NOTE: PLANS APPEAR TO SHOW MIXED USE | | | OCCP. PLEASE ADJUST ELECTRICAL PLANS. | | | PLEASE SEE 2002 NEC FOR ALL MIN REQUIRED | | | FOR RESIDENTIAL. | | | | | | PLEASE NOTE: DUE TO PLANS NOT BEING | | | COMPLETE AT THIS TIME, A COMPLETE REVIEW | | | FOR CODE COMPLIANCE CAN NOT BE DONE. | | | | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY HAVE AN | | | AFFECT ON ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-02-25 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-02-25 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2005-02-25 00:00:00 | SEE PREVIOUS NOTES FOR PLAN REVIEW. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-12-27 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-02-25 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2005-02-23 00:00:00 | 1. NO SMOKE DETECTORS SHOWN IN | | | APARTMENT. ELECTRIC POWERED | | | SMOKE DETECTORS ARE REQUIRED INSIDE | | | AND OUTSIDE OF EVERY SLEEPING ROOM. | | | | | | 2. BUILDING ADDRESS REQUIRED ON | | | PROPER ELEVATION. A MINIMUM OF 6" | | | HIGH NUMBERS ARE REQUIRED. | | | | | | 3. NO HANDRAIL (S) SHOWN FOR | | | INTERIOR STAIR. | | | | | | 4. THE FIRST FLOOR LEVEL MUST | | | MEET ALL OF THE CODE REQUIREMENTS | | | FOR MERCANTILE OCCUPANCIES. PROPER | | | TENANT SEPARATIONS, OPENING | | | PROTECTIVES, PORTABLE FIRE | | | EXTINGUISHERS, EMERGENCY LIGHTS | | | AND EXIT SIGNS ARE REQUIRED. | | | PROPER DOOR LOCKS ARE REQUIRED. | | | THE FIRST FLOOR IMPROVEMENTS ARE | | | SUBJECT TO FIELD INSPECTION. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 | | | | | | APPROVED PROVISO: | | 2004-12-27 00:00:00 | 1. BUILDING ADDRESS REQUIRED ON | | | PROPER ELEVATION. A MINIMUM OF 6" | | | HIGH NUMBERS ARE REQUIRED. | | | | | | 2. PLEASE INDICATE ALL HORIZONTAL | | | AND VERTICAL FIRE SEPARATIONS BETWEEN | | | DIFFERENT TENANTS AND DIFFERENT | | | OCCUPANCY TYPES. ALSO PLEASE | | | SHOW REQUIRED OPENING PROTECTIVES. | | | | | | 3. IT APPEARS THAT AN EXIT SIGN FOR | | | OFFICE/RETAIL B MAY BE LOCATED INFRONT | | | OF A GARAGE DOOR. | | | | | | 4. PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATIONS FOR ALL WALLS AND | | | CEILINGS. | | | | | | 5. HOW IS STAIR SEPARATED FROM | | | REMAINDER OF BUILDING. | | | | | | 6. NO DOOR SCHEDULE PROVIDED. | | | | | | 7. NO FIRE SAFING DETAILS PROVIDED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-05-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-20 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-20 |
Time |
10:48 |
Sent To |
E |
|
| Notes |
| 2005-05-20 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-04-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-18 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-18 |
Time |
14:38 |
Sent To |
B |
|
| Notes |
| 2005-04-18 00:00:00 | TO "JWITMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-08 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-08 |
Time |
15:29 |
Sent To |
E |
|
| Notes |
| 2005-03-08 00:00:00 | TO "DP" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-25 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-25 |
Time |
11:02 |
Sent To |
FIRE |
|
| Notes |
| 2005-02-25 00:00:00 | TO "F" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-03 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-03 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2005-02-03 00:00:00 | TO COMM BOARD/#13 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-11 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2004-12-10 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2004-12-10 00:00:00 | SENT TO COMM BD#42 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-02-25 |
Time |
07:12 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2005-02-23 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2005-02-23 00:00:00 | MRS. DARBY 799-3576 676-6841, CALL IF | | | PROBLEMS OR QUESTIONS. | | | | | | NO MECHANICAL PLANS OR CONTRACTOR | | | INDICATED ON PERMIT APPLICATION.PLEASE | | | PROVIDE PLANS WITH MECHANICAL PERMIT | | | APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-31 |
Time |
10:16 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-12-31 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2004-12-31 00:00:00 | DENIED: | | | PLAN SHEET 2 OF 6 INDICATES A "NEW | | | STACKABLE WASHER/DRYER".PROVIDE | | | INFORMATION ON THE EXHAUST FROM THE | | | DRYER.INDICATE DUCT SIZE, MATERIAL, | | | LAYOUT AND TERMINATION.PROVIDE | | | INFORMATION ON PENETRATIONS THROUGH ANY | | | RATED WALLS, PARTITIONS OR | | | CEILING/ROOF. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-02-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-02-19 |
Time |
07:08 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-02-19 |
Time |
07:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-10 |
Time |
09:49 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-01-10 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2005-01-10 00:00:00 | DENIED; | | | 1.NOT ENOUGH INFORMATION TO DO A | | | PLUMBING REVIEW. PLEASE SHOW RISER | | | DIAGRAMS FOR SANITARY AND WATER. SHOW | | | HOW RAIN IS DISCHARGED FROM FLAT ROOF | | | AREA. | | | 2.DRINKING FOUNTAINS ARE REQUIRED TO | | | MEET MINIMUM PLUMBING FACILITIES. SEE | | | FBC PLUMGBING TABLE 403.1. | | | 3.OFFICE SPACE C & D. BATHROOM | | | FACILITIES SHALL BE EATHER SEPARATE OR | | | PUBLIC CUSTOMER FACILITIES. SEC.403.5 | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-12 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-12 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-12 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2005-01-12 00:00:00 | PROVISO: NEED TO APPLY FOR A RENTAL | | | OCCUPATIONAL LICENSE BEFORE BUIDLING IS | | | C.O. |
|
|