| Plan Review Stops For Permit 04120512 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-02-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-27 |
Time |
13:07 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-02-27 |
Time |
13:07 |
Sent To |
PC |
|
| Notes |
| 2006-02-27 00:00:00 | BUILDING PROVISO: | | | A SEPERATE PERMIT REQUIRED FOR WINDOWS | | | AND SLIDING GLASS DOORS.JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-03-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-03-23 |
Time |
14:42 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-03-23 |
Time |
14:13 |
Sent To |
PC |
|
| Notes |
| 2005-03-23 00:00:00 | ***PROVISO*** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)LOCAL OR STATE PRODUCT APPROVALS | | | REQUIRED FAC9B72.TRACO IS LISTED ON | | | THE WEBSITE BUT I WAS UNABLE TO LOCATE | | | THE SPECIFIC PRODUCT.I COULD NOT | | | LOCATE THE MANUFACTURER FOR THE SLIDING | | | GLASS DOORS ON THE WEBSITE.YOU MAY | | | APPLY FOR A LOCAL PRODUCT APPROVAL, | | | APPLICATION ATTACHED, FOR THIS PRODUCT | | | IF THEY HAVE NOT OBTAINED A STATE | | | PRODUCT APPROVAL. | | | | | | WWW.FLORIDABUILDING.ORG | | | | | | SEPARATE PERMIT REQUIRED FOR WINDOW AND | | | SLIDING GLASS DOOR |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-02-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-02-17 |
Time |
10:59 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2005-02-17 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2005-02-17 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04120512 | | | ADD: 1701 S FLAGLER # 1807 | | | CONT:PROJECT ONE INTERIORS | | | TEL: (561)541-4555 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | DESIGN PROFESSIONAL TO SUPPLYPOS/NEG | | | PRESSURES AS TO ASCE 7-98, INDICATE IF | | | THIS UNIT IS LOCATEED IN A INTERIOR ZONE | | | OR END ZONE. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-01-11 |
Time |
16:35 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2005-01-11 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2005-01-11 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04120512 | | | ADD: 1701 S FLAGLER DR # 1807 | | | CONT:PROJECT ONE INTERIORS | | | TEL: (561)541-4555 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | | | | 1)PROVIDE NOC RECORDED WITH THE CLERK OF | | | COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | SHEET A-1 DEMO NOTES CORRECT THE | | | MUNICIPALITY NOT PALM BEACH. | | | | | | 3) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS | | | B) SLIDING DOORS | | | | | | 4) PRESSURES ARE TO REFLECT THAT OF A 18 | | | STORY BUILDING "C" ZONE, FOR A | | | ZONE 5 (END ZONE) -139. | | | | | | REVIEW BY JIM WITMER | | | (561) 805-6715 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-01-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-10 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-10 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2006-01-10 00:00:00 | REV'S OK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-14 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-14 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2005-12-14 00:00:00 | ****** UNSAT ***** | | | | | | PLEASE SEE SOME ITEMS FROM PREVIOUSLY | | | REDLINED PLANS AND SOME NEW ITEMS DUE TO | | | CHANGES IN SCOPE OF WORK NEED TO BE | | | CORRECTED. | | | | | | | | | 1)NOTE: PLEASE SEE MISSING RECEPTS PER | | | 210.52 | | | | | | 2)NOTE: PLEASE SEE MISSING RECEPTS PER | | | 210.52C1 | | | | | | 3)NOTE: PLEASE NOW SEE A DINING ROOM GFI | | | IS NOW ON WITH THE BATH GFI CIRCUIT | | | WHICH IS NOT PERMITTED. | | | PLEASE SEE 210.52D AND 210.11C3 WHICH | | | DOES NOT PERMIT ANY OTHER AREA RECEPTS | | | ON WITH THE BATH DEDICATED 20A CIRCUIT. | | | | | | 4)NOTE: PLEASE ALSO NOW SEE ITEM WHICH | | | WAS REDLINEDORIGINALLY. PLEASE SEE | | | SD'S ARE SHOWN ON WITH BATH LIGHTING | | | CIRCUIT, THIS IS OK, HOWEVER THIS | | | CIRCUIT IS NOW REQUIRED TO BE AFCI | | | PROTECTED AS THE 2002 NEC 210.12 | | | REQUIRES ALL "OUTLETS" IN BEDRMS TO BE | | | ARC FAULT PROTECTED. | | | | | | 5)NOTE: PLEASE SEE NFPA-72 11.8.3 WHICH | | | REQUIRES SD'S TO BE A MIN OF 3' FROM ANY | | | BATH DOORS. | | | | | | 6)NOTE: PLEASE LIST THE MIN REQUIRED AWG | | | ON PANEL SCHEDULE. PLEASE SEE 240.4, | | | 310.16 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-03-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-23 |
Time |
11:30 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-03-23 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2005-03-23 00:00:00 | REDLINED PLANS | | | | | | 210.52C1 | | | ARC FAULT PROTECTION PER 2002 NEC, | | | 210.12, PLEASE SEE CIRCUITING OF SD'S. | | | NO ARC FAULT PROTECTION INDICATED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-02-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-09 |
Time |
13:27 |
Rev Time |
0.20 |
| Received By |
dpalmer |
Date |
2005-02-09 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2005-02-09 00:00:00 | *************** UNSAT ************ | | | | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW WHICH STILL NEED TO BE | | | ADDRESSED. | | | | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH PANEL | | | SCHEDULE. | | | 215.5 | | | | | | 2)NOTE: PLEASE SEE SOME MISSING RECEPTS | | | PER 210.52 NEW OR EXISTING? PLANS | | | REDLINED AT LOCATIONS OF QUESTION. | | | | | | 3)NOTE: PLEASE SEE PLANS MENTIONS TO | | | REPLACE EXISTING PANEL, HOWEVER PANEL | | | SCHEDULE MENTIONS EXISTING PANEL, NO | | | CHANGES?? | | | IF PANEL IS BEING CHANGED OUT, PLEASE | | | PROVIDE INFORMATION ON NEW PANEL EVEN IF | | | ITS THE SAME AS EXISTING. | | | 215.5 | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLYINSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-12-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-16 |
Time |
15:59 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-12-16 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2004-12-16 00:00:00 | *********** UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE PLANS MENTION TO | | | CHANGE OUT PANEL, YET NO INFORMATION IS | | | PROVIDED FOR THIS. | | | SIZE? CONDUCTORS? MB? ETC. | | | 215.5 | | | | | | 2)NOTE: PLEASE SEE 210.52D,210.11C3, | | | BATHS TO BE 20A, #12. | | | | | | 3)NOTE: PLEASE SEE 2002 210.12 FOR ARC | | | FAULT PROTECTION OF NEW ELECTRICAL IN | | | BEDRMS. | | | | | | 4)NOTE: PLEASE SEE 210.52C1 FOR MISSING | | | GFI RECEPTS ALONG KITCHEN COUNTERSPACE. | | | NEW ? OR EXSITING? | | | | | | 5)NOTE: PLEASE PROVIDE CIRCUITING ON | | | PLANS AND CORRELATE WITH A PANEL | | | SCHEDULE FOR NEW CIRCUITS BEING | | | INSTALLED.215.5 | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS FOR | | | REVIEW AND STAMPING. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-03-02 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-03-02 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-03-02 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-02-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-25 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-25 |
Time |
13:00 |
Sent To |
B |
|
| Notes |
| 2006-02-25 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-01-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-04 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-04 |
Time |
14:49 |
Sent To |
E |
|
| Notes |
| 2006-01-04 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-12-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-10 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-10 |
Time |
15:16 |
Sent To |
E |
|
| Notes |
| 2005-12-10 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-21 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-21 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2005-03-21 00:00:00 | TO "COMM" BD#6 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-04 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-04 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2005-02-04 00:00:00 | TO COMM BD#12 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-02-09 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-11 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2004-12-10 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2004-12-10 00:00:00 | SENT TO COMM BD#57 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-11 |
Time |
06:53 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2005-01-10 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2005-01-11 00:00:00 | NO MECHANICAL PLANS OR CONTRACTOR | | | INDICATED WITH PERMIT APPLICATION. | | | PROVIDE PLANS WITH MECHANICAL PERMIT | | | APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-10 |
Time |
13:58 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-01-10 |
Time |
13:57 |
Sent To |
|
|
| Notes |
|
|