Plan Review Details - Permit 04120220
Plan Review Stops For Permit 04120220
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2005-08-28 Cont ID  
Sent By jwitmer Date 2005-08-28 Time 08:39 Rev Time 0.66
Received By jwitmer Date 2005-08-28 Time 08:39 Sent To PC
Notes
2005-08-28 00:00:008-28-05 SUBMITTALS: TIE IN SURVEY
 SOILS LETTER
 TERMITE TREATMENT CERTIFICATE

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2005-07-27 Cont ID  
Sent By jwitmer Date 2005-07-27 Time 06:52 Rev Time 0.55
Received By jwitmer Date 2005-07-27 Time 06:52 Sent To PC
Notes
2005-07-27 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04120220
 ADD:4660 PORTOFINO WAY
 CONT: EPOCH
 TEL: (561)723-0152
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVISION
 ACTION: DENIED
  
 SEE ZONING REQUIREMENT FOR MINOR
 AMENDMENT
 JIM WITMER
 BUILDING PLAN REVIEW

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-04-05 Cont ID  
Sent By jwitmer Date 2005-04-05 Time 14:40 Rev Time 0.00
Received By jwitmer Date 2005-04-05 Time 14:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-03-16 Cont ID  
Sent By jwitmer Date 2005-03-16 Time 10:48 Rev Time 0.77
Received By jwitmer Date 2005-03-16 Time 10:48 Sent To PC
Notes
2005-03-16 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04120220
 ADD: 4600 PORTOFINO WAY
 CONT:EPOCH
 TEL: (561)723-0152
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 3RD REVIEW
 ACTION: DENIED
  
 1) TWO SETS OF PLANS SUBMITTED, THREE
 ARE REQUIRED.
  
 2) BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-02-15 Cont ID  
Sent By jwitmer Date 2005-02-15 Time 15:24 Rev Time 3.33
Received By jwitmer Date 2005-02-15 Time 15:24 Sent To  
Notes
2005-02-15 00:00:00BUILDING PLAN REVIEW
 PERMIT:04120220
 ADD:4600 PORTOFINO WAY
 CONT:EPOCH
 TEL:(561)723-0152
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 2ND REVIEW
 ACTION: DENIED
  
 1) ALTHOUGH THIS BUILDUNG DOESNOT A
 SPECIAL INSPECTOR, THE RESIDENT
 INSPECTOR THAT WILL BE ON SITE SHALL DO
 THE STRUCTURAL INSPECTIONS, REQUIRING
 (3) SETS OF PLANS, TESTING REPORTS AND
 OTHER RELATED DOCUMENTS.
  
 2)FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) EXTERIOR DOORS W/ TRANSOM &
 SIDELIGHTS
 B) MULLIONS FOR WINDOWS
 C) MULLIONS FOR DOORS
 D) STORM SHUTTERS
 E) TRUSS ANCHORS
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 3)1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
  
 4) BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-01-05 Cont ID  
Sent By jwitmer Date 2005-01-05 Time 07:37 Rev Time 4.44
Received By jwitmer Date 2005-01-05 Time 07:37 Sent To  
Notes
2005-01-05 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04120220
 ADD: 4400 PORTOFINO WAY
 CONT: EPOCH PROPERTIES, INC
 TEL: (407)718-8932
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 1) AM-1 BUILDING DATA CORRECT: A-2 SMALL
 ASEEMBLY MORE THAN 100 SEE 304.2.1(2).
  
 2) AM-1 NOTES, ROOF COVERING CORRECT:
 2A) REFRENCE TO THE S.F.B.C.
 2B) UNDERLAYMENT @ 10" O.C. SEE
 1507.4.1.2(2)(3)
  
 3) ROOF SHEATHING NOTE CORRECTION:
 32/16,19/32" SEE 2309.3A* SPAN RATING
 TO
 BE 40/20, FULL 5/8" PLYWOOD HAS A 32/16
 SPAN RATING.
  
 4) AM-1 ROOF COVERING NOTES: REFRENCES
 CHAPTER 3207 WHICH DEALS WITH SPACE
 UNDER PUBLIC RIGHT OF WAY, EXPLAIN?
  
 5) AM-1 HANDICAPPED ACCESSIBILITY
 NOTE CORRECT CODE REFRENCE, REFRENCES
 THE FL ACCESSIBILITY CODE OF 1994,
 NOT THE CURRENT 2001 FLORIDA
 ACCESSIBILITY CODE, CHAPTER 11.
  
 6) FBC 13-103.1.1.1THE PROFESSIONALS
 RESPONSIBLE FOR THE DESIGN OF THE
 BUILDING, ELECTRICAL, LIGHTING,
 MECHANICAL AND PLUMBING SYSTEMS SHALL
 EACH SIGN THE ENERGY CODE COMPLIANCE
 FORM, TO CERTIFY COMPLIANCE. THE ENERGY
 FORMS ARE COPIES, PROVIDE ORIGINALS.
 PLANS, SPECIFICATIONS,REPORTS OR OTHER
 DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 7) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 WHERE THE BEARING CAPACITY OF THE SOIL
 IS NOT DEFINITLY KNOWN OR IS IN QUESTION
 THE BUILDING OFFICIAL MAY REQUIRE EXPLOR
 ATIONS, TEST OR OTHER ADEQUATE PROOF AS
 TO THE PERMISSIBLE SAFE BEARING
 CAPACITY. REQUIRED TEST AND RECOMMENDA-
 TIONS SUBMITTED TO VERIFY BEARING CAPA-
 CITY SHALL BE CERTIFIED BY A GEOTECH-
 NICALREPORT FROM A DESIGN PROFESSIONAL
 PROPERLY LICENSED IN THE STATE OF
 FLORIDA.
  
 8) AM-2 THE PLANS INDICATE A THEATRE BUT
  
 THE PLANS DO NOT INDICATE WHERE THE
 WHEEL CHAIR SEATING WILL BE? FAIR
 HOUSING ACT ANSI 117 SECTION 802.
  
 9) AM-2 BILLARD ROOMTHE BILLARD TABLES
 ARE NOT INDICATED, PROVIDE THE CLEAR
 WIDTH OF THE ACCESSIBLE ROUTE, ANSI 117
 TABLE 403.5.
  
 10) AM-2/ AM-12 BAR OR KITCHEN DETAIL,
 MAXIMUM SINK HEIGHT, SEE ANSI 117
 SECTION 606.3 MAXIMUM HEIGHT OF 34".
 NOTE ALL SECTIONS OF 606 FOR SINKS &
 LAVATORIES.
  
 11) AM-2 NOTE, PLANS DO NOT INDICATE A
 POOL BUT IF POOL SHALL BE NEXT TO THE
 CLUBHOUSE A "EFFECTIVE BARRIER" SHALL
 COMPLY WITH DEPT. OF HEALTH RULE 64-E9
 FOR PUBLIC SWIMMING POOLS BEFORE A
 ISSUANCE OF CERTIFICATE OF OCCUPANCY
 FOR
 THE CLUBHOUSE, ( IF POOL IS BUILT
 CONCURRENTLY WITH CLUBHOUSE).
 11A) AM-7 DOOR HARDWARE NOTE# 4, THE
 CARD SWIPE LOCKING SYSTEM FROM THE
 COLONADE, IS THIS IN LEU OF A BARRIER?
  
 12) AM-7 WINDOW SCHEDULE, CORRECT: PLANS
 INDICATE THE WRONG WIND VELOCITY.
 FIGURE 1606 WIND-BORNE DEBRIS
 REGION; INDICATES THAT W.P.B. CITY OF IS
 LOCATED IN THE 140 MPH ZONE. PLANS ARE
 TO INDICATE THIS.
  
 13) AM-7 WINDOW AND DOOR REQUIREMENTS,
 THE ARCHITECT OF RECORD DOES NOT
 INDICATE WHAT WIND PARAMETERS HE
 DESIGNED TOO? FL. BLD CODE 1606.1.7
 THE FOLLOWING INFORMATION RELATED TO
 WIND SHALL BE SHOWN ON THE CONSTRUCTION
 DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 14) AM-7 NON-RATED EXTERIOR FRAME WALL,
 THE WORD "OR EQUAL",104.2.1 W.P.B.
 ADMINISTRATIVE CODE DRAWINGS &
 SPECIFICATIONS SHALL CONTAIN
 INFORMATION, IN THE FORM OF NOTES OR
 OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO
 CONFORMITY WITH THE TECHNICAL CODES.
 SUCH INFORMATION SHALL BE SPECIFIC
 AND THE TECHNICAL CODES "SHALL NOT BE
 CITED AS A WHOLE OR IN PART, NOR THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED
 AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION".
  
  
 15) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
 FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) WINDOWS
 B) EXTERIOR DOORS
 C) MULLIONS
 D) STORM SHUTTERS
 E) TRUSS ANCHORS
 F) ROOFING ASSEMBLIES
  
 16)PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
  
 17) FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 18)1707.4.5.1 MULLIONS OCCURRING BETWEEN
 INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
 19)1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
  
 20) 301.13.1 GROUND MOUNTED A/C UNITS:
 GROUND-MOUNTED UNITS FOR R3 RESIDENTIAL
 APPLICATIONS MAY BE ANCHORED WITH # 14
 SCREWS WITH GASKETED WASHERS ACCORDING
 TO THE FOLLOWING:
 1) FOR UNITS WITH SIDES LESS THAN 12",
 ONE SCREW SHALL BE USED AT EACH SIDE OF
 THE UNIT.
 2) FOR UNITS BETWEEN 12" & 24", TWO
 SCREWS SHALL BE USED PER DIDE.
 3) FOR UNITS BETWEEN 24" & 36", THREE
 SCREWS SHALL BE USED PER SIDE.
 4) FOR UNITS GREATER THAN 36" OR 5 TONS
 ANCHORAGE SHALL BE DESIGN IN ACCORDANCE
 WITH 301.13. (140 MPH).
  
 21) 1503.4.4 PROTECTION AGAINST DECAY &
 TERMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 22) AM-8 TYPE "A" ROOF TRUSS ANCHOR
 DETAIL, INDICATE TWO TYPES OF ANCHORS,
 WITH A COMBINED VALUE OF 2500 LBS
 UPLIFT. USP CATALOG FOR A SINGLE
 HTA20-18 THE VALUE IS 1200 WHEN YOU
 PLACE (2) STRAPS WITHIN 8" OF EACH OTHER
  
 THERE IS A DERATING BECAUSE OF THE
 LARGER CONE PULLOUT. USP INDICATES THAT
 (2) STRAPS ON A SINGLE PLY TRUSS IS GOOD
 FOR 2375, AND FOR A (2) PLY TRUSSTHE
 VALUE IS 2400, PLEASE RE-EVALUATE.
  
 23) BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-07-05 Cont ID  
Sent By dpalmer Date 2005-07-05 Time 12:44 Rev Time 0.50
Received By dpalmer Date 2005-07-05 Time 12:44 Sent To  
Notes
2005-07-05 00:00:00REV ALL THREE SHEETS.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-03-31 Cont ID  
Sent By dpalmer Date 2005-03-31 Time 10:29 Rev Time 0.30
Received By dpalmer Date 2005-03-31 Time 10:29 Sent To  
Notes
2005-03-31 00:00:003RD SET STAMPED.;

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-02-15 Cont ID  
Sent By dpalmer Date 2005-02-15 Time 06:21 Rev Time 0.00
Received By dpalmer Date 2005-02-15 Time 06:17 Sent To  
Notes
2005-02-15 00:00:00**** UNSAT ***
  
 1)NOTE: PLEASE SEE ONLY TWO SETS WERE
 SUBMITTED FOR STAMPING.
 STAMPED TWO SETS, NEED THIRD SET FOR
 STAMPING.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-12-23 Cont ID  
Sent By dpalmer Date 2004-12-23 Time 13:28 Rev Time 0.50
Received By dpalmer Date 2004-12-23 Time 13:12 Sent To  
Notes
2004-12-23 00:00:00******** UNSAT **********
  
  
 1) NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
 PLEASE SEE AIC RATING IS SHOWN FOR ALL
 BUT MAIN #2.
  
 2)NOTE: PLEASE PROVIDE CLEAR SPCE AND
 NOTES FOR CLEARENCES FOR ELECTRICAL
 PANELS AND MAINS PER 110.26.
 THESE ARE ALSO NOT PERMITTED IN "STORAGE
 AREAS/RMS. PLEASE SPECIFY
 STORAGE.WITCHBOARDS SHALL BE PLACED SO
 AS TO REDUCE TO A MINIMUM THE
 PROBABILITY OF COMMUNICATING FIRE TO
 ADJACENT COMBUSTIBLE MATERIALS. WHERE
 INSTALLED OVER A COMBUSTIBLE FLOOR,
 SUITABLE PROTECTION THERETO SHALL BE
 PROVIDED.
  
 3)NOTE: PLEASE SEE MISSING EQUIPMENT
 GROUNDING FROM PANEL "DPA" TO "B"
 PLEASE SIZE PER 250.122
  
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 ONLY INSERT NEW REVISED SHEETS INTO
 THREE COMPLETE SETS FOR REVIEW AND
 STAMPING.
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWERS WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2004-12-06 Cont ID  
Sent By mamini Date 2004-12-06 Time 16:06 Rev Time 0.50
Received By mamini Date 2004-12-06 Time 16:06 Sent To  
Notes
2004-12-06 00:00:00PASSED:
  
 1. SEE PERMIT# 04120218 FOR
 UNDERGROUND UTILITIES AND SITE WORK,
 PHASE II.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2005-07-20 Cont ID  
Sent By mwennerg Date 2005-07-20 Time 13:37 Rev Time 0.00
Received By mwennerg Date 2005-07-20 Time 13:37 Sent To  
Notes
2005-07-20 00:00:00REVISION DATED 6/15/05

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2005-04-12 Cont ID  
Sent By mwennerg Date 2005-04-12 Time 10:19 Rev Time 0.00
Received By mwennerg Date 2005-04-12 Time 10:19 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2005-03-15 Cont ID  
Sent By nmccray Date 2005-03-15 Time 15:42 Rev Time 0.00
Received By nmccray Date 2005-03-15 Time 15:42 Sent To  
Notes
2005-03-15 00:00:00ONLY 2 SETS OF PLANS
  
 NATE MCCRAY, CAPTAIN
 561-805-6722 OR 561-835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-12-30 Cont ID  
Sent By mwennerg Date 2004-12-30 Time 13:52 Rev Time 0.00
Received By mwennerg Date 2004-12-30 Time 13:53 Sent To  
Notes
2004-12-30 00:00:001) WHERE BUILDINGS ARE SUBJECT TO AN
 OCCUPANT LOAD OF 100 OR MORE, PANIC
 HARDWARE IS REQUIRED.
 2) PLANS DON'T SHOW AN ADDRESS NUMBER ON
 THE FRONT ELEVATION. NUMBER IS TO BE AT
 LEAST 6" IN HEIGHT AND CONTRASTING TO
 BACKGROUND.
 3) SHOP DRAWINGS WILL BE REQUIRED FOR
 FIRE ALARM SYSTEM.
 4) SHOP DRAWINGS FOR SPRINKLER SYSTEM
 WILL BE REQUIRED.
 5) PLEASE CLARIFY LOCATIONS OF EXIT
 SIGNS AND EMERGENCY LIGHTING FOR MEANS
 OF EGRESS.
  
  
 M.R. WENNERGREN, A/CAPT
 WPBFR(561) 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-08-02 Cont ID  
Sent By adarroug Date 2005-08-02 Time 15:01 Rev Time 0.00
Received By adarroug Date 2005-08-02 Time 15:01 Sent To  
Notes
2005-08-03 00:00:00TO "COMM" BD#5
2005-08-02 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-06-15 Cont ID  
Sent By shill Date 2005-06-15 Time 15:34 Rev Time 0.00
Received By shill Date 2005-06-15 Time 15:34 Sent To  
Notes
2005-07-22 00:00:00TAKEN OFF THE BD/TO JWITMER DESK
2005-06-21 00:00:00TO "COMM" BD#32
2005-06-15 00:00:00WAITING FOR COMM BOARD
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-03-30 Cont ID  
Sent By adarroug Date 2005-03-30 Time 14:13 Rev Time 0.00
Received By adarroug Date 2005-03-30 Time 14:13 Sent To  
Notes
2005-03-30 00:00:00TO "COMM" BD#56

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-02-03 Cont ID  
Sent By mjacobs Date 2005-02-03 Time 12:55 Rev Time 0.00
Received By mjacobs Date 2005-02-03 Time 12:55 Sent To  
Notes
2005-02-03 00:00:00TO "COMM BD#33

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-04-15 Cont ID  
Sent By mjacobs Date 2005-01-05 Time 12:54 Rev Time 0.00
Received By pkrauss Date 2004-12-06 Time 13:30 Sent To  
Notes
2004-12-06 00:00:00SENT TO COMM BD#35

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2006-02-27 Cont ID  
Sent By hmoser Date 2006-02-27 Time 18:10 Rev Time 0.00
Received By hmoser Date 2006-02-27 Time 18:10 Sent To  
Notes
2006-02-27 00:00:00LETTER WITH PERMIT #04090363

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2005-07-19 Cont ID  
Sent By hmoser Date 2005-07-19 Time 09:36 Rev Time 0.00
Received By hmoser Date 2005-07-19 Time 09:14 Sent To  
Notes
2005-07-19 00:00:00PASS PRIVISO
 PLEASE REFER TO SECTION 307.2.3
 AUXILIARY DRAIN PAN WITH OVERFLOW
 PROTECTION REQUIRED.SEE AIRHANDLER
 DETAIL ON PAGE AMC-4.
 PLEASE REFER TO SECTION 602.2.1 METERALS
 EXPOSED WITHIN PLENUMS.
 PLAN REVIEW BY HAROLD MOSER.561-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-04-15 Cont ID  
Sent By pkrauss Date 2005-04-15 Time 07:55 Rev Time 0.40
Received By pkrauss Date 2005-04-15 Time 07:45 Sent To  
Notes
2005-04-15 00:00:00PROVISO:
 PER 2001 FBC/M 307.2.3, AUXULIARY DRAIN
 PAN WITH OVERFLOW PROTECTION REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2005-03-02 Cont ID  
Sent By pkrauss Date 2005-03-02 Time 14:56 Rev Time 0.55
Received By pkrauss Date 2005-03-02 Time 14:44 Sent To  
Notes
2005-03-02 00:00:003 SETS OF PLANS REQUIRED, ONLY 2
 SUBMITTED
  
 PROVISO:
 PER 2001 FBC(M)307.2.3, AUXILIARY DRAIN
 PAN REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-01-04 Cont ID  
Sent By pkrauss Date 2005-01-04 Time 15:07 Rev Time 1.00
Received By pkrauss Date 2005-01-04 Time 14:56 Sent To  
Notes
2005-01-04 00:00:00DENIED:
 1.PLAN SHEET AMC-1, PLEASE NOTE THE
 LOCATION OF THE THE O.A. INTAKE IN
 RELATION TO THE CU 3, 4 & 5,O.A.
 INTAKE SHALL BE LOCATED AS NOT TO
 RECIRCULATE HEAT/EXHAUST FROM THE
 CONDENSING UNITS PER 2001 FBC(M)501.3.
  
 2.PLAN SHEET AMC-4 AHU INSTALLATION
 DETAIL INDICATES CLOSET AS A RETURN AIR
 PLENUM.PER 2001 FBC(M)606.2.2, WHERE
 MULTIPLE AIR HANDLING SYSTEMS SHARE A
 COMMON PLENUM AND THE COMBINED DESIGN
 CAPACITY IS GREATER THAN 2,000 CFM, THE
 SUPPLY AND RETURN AIR DUCTS SHALL HAVE
 DUCT SMOKE DETECTORS.
  
 3.PLEASE NOTE, PVC & CPVC ARE NOT
 PERMITTED FOR THE CONDENSATE LOCATED IN
 THE RETURN AIR PLENUMS.
  
 4.PLAN SHEET PM-2 CONDENSATE DISPOSAL
 DETAIL,PER 2001 FBC 1503.4.4,
 CONDENSATE SHALL TERMINATE A MINIMUM OF
 12" FROM THE BUILDING STRUCTURE.
  
 5.AUXILIARY DRAIN PAN WITH OVERFLOW
 PROTECTION REQUIRED PER 2001
 FBC(M)307.2.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 5 Status P Date 2005-08-26 Cont ID  
Sent By kstevens Date 2005-08-26 Time 17:00 Rev Time 0.60
Received By kstevens Date 2005-08-26 Time 17:00 Sent To  
Notes
2005-08-26 00:00:00REVISION APPROVED SHT PM-1 - SHT PM-2 NO
 CHANGE AS INDICATED BY LETTER FROM
 PROJECT ARCHITECT. 7-29-5

Review Stop P PLUMBING
Rev No 4 Status F Date 2005-07-14 Cont ID  
Sent By kstevens Date 2005-07-14 Time 07:31 Rev Time 0.50
Received By kstevens Date 2005-07-14 Time 07:30 Sent To  
Notes
2005-07-14 00:00:00REVISION DENIED
 REFERENCE: FBC-2001 CHAPTER 1
  
 1. SHTS PM-1 & PM-2 REVISION NUMBER 2
 INDICATED IN REVISION SECTION, BUT THE
 REVISION WAS NOT LOCATED ON THE SHEETS.
 PLEASE CLOUD AND NUMBER EACH REVISION ON
 THE SHEET TO INDICATE WHERE THE REVISION
 IS LOCATED AND WHAT IS THE EXTENT OF THE
 REVISION. SECTION 104.2.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-04-18 Cont ID  
Sent By kstevens Date 2005-04-18 Time 06:57 Rev Time 0.33
Received By kstevens Date 2005-04-18 Time 06:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-02-15 Cont ID  
Sent By kstevens Date 2005-02-15 Time 09:26 Rev Time 0.50
Received By kstevens Date 2005-02-15 Time 09:26 Sent To  
Notes
2005-02-15 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
  
 1) ONLY TWO SETS OF PLANS SUBMITTED AND
 HAVE BEEN STAMPED. THIRD SET REQUIRED.
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-01-06 Cont ID  
Sent By jleech Date 2005-01-06 Time 13:23 Rev Time 0.00
Received By jwitmer Date 2005-07-27 Time 06:52 Sent To  
Notes
2005-01-06 00:00:00DENIED;
 1.A MEANS OF THURMAL EXPANSION IS
 REQUIRED SEE SEC.607.3.1.2.
 2.SHOCK ARRESTORS ARE REQUIRED AT BAR
 SINK SEC604.9
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 3 Status P Date 2005-12-09 Cont ID  
Sent By eschneid Date 2005-12-09 Time 11:56 Rev Time 0.00
Received By eschneid Date 2005-12-09 Time 11:55 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2005-07-26 Cont ID  
Sent By mmclean Date 2005-07-26 Time 14:05 Rev Time 0.00
Received By mmclean Date 2005-07-26 Time 14:05 Sent To  
Notes
2005-07-26 00:00:00DENIED,
 1. MUST APPLY FOR A MINOR PD AMENDMENT
 FOR THE MAIL BOXES & ADDT'L HEIGHT.
 PLEASE CALL JOSH LONG, SENIOR PLANNER
 FOR PROCESS 822-1435

Review Stop Z ZONING
Rev No 1 Status P Date 2004-12-14 Cont ID  
Sent By mmclean Date 2004-12-14 Time 15:51 Rev Time 0.00
Received By mmclean Date 2004-12-14 Time 15:51 Sent To  
Notes
2004-12-14 00:00:00APPROVED BY JOSH LONG, PLANNER 822-1449