| Plan Review Stops For Permit 04120193 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-08-01 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-08-01 |
Time |
10:48 |
Sent To |
M |
|
| Notes |
| 2006-08-01 00:00:00 | PLANS REVISED TO SHOW SPRAYED FOAM | | | INSULATION IN ATTIC. ENERGY CALCULATIONS | | | REVISED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-06-28 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-06-28 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2006-06-28 00:00:00 | DENIED | | | | | | 1) BUILDING PROVISO REQUIRED REVISED | | | ENERGY CALCULATIONS TO REFLECT THE ICF | | | EXTERIOR WALLS. HOWEVER, THE NEW ENERGY | | | CLACS. SUBMITTED LISTS THE SINGLE | | | ASSEMBLY CEILING AS R-20 AND THE PLANS | | | SPECIFY R-30. THE OWNER HAS INDICATED | | | THAT THE CEILING WAS INSULATED WITH A | | | SPRAYED ON FOAM PRODUCT. THEREFORE, THE | | | PLANS MUST BE REVISED TO REFLECT THE | | | CHANGES AND THE PRODUCT INFORMATION | | | (MANUFACTURERS SPECS. AND INSTALLATION | | | INSTRUCTIONS) FOR THE SPRAYED FOAM | | | INSULATION SUBMITTED. TWO COPIES OF ALL | | | REQUESTED ITEMS ARE REQUIRED. TWO | | | SIGNED AND SEALED LETTERS FROM THE | | | DESIGNER OF RECORD (ENGINEER) STATING | | | THAT THE CEILING INSULATION WAS CHANGED | | | FROM R30 BATTS TO R20 SPRAYED FOAM | | | INSULATION WILL BE ACCEPTABLE IN LIEU OF | | | REVISING THE PLAN PAGES. | | | | | | 2) THE COMMENTS FROM THE MECHANICAL | | | PLANS EXAMINER MUST ALSO BE ADDRESSED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-01-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-01-04 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-01-04 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2006-01-04 00:00:00 | PROVISO | | | | | | 1) SUBMIT REVISED ENERGY CALCULATIONS | | | FOR ICF SYSTEM. | | | | | | 2) A SEPARATE PERMIT IS REQUIRED FOR THE | | | ROOFING. NO PRODUCT APPROVALS WERE | | | SUBMITTED FOR THE ROOF. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-12-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-12-05 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-12-05 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2005-12-05 00:00:00 | DENIED | | | | | | 1) THE NOC HAS EXPIRED WORK MUST | | | COMMENCE ON THE PROJECT WITHIN 90 DAYS | | | OF RECORDING. A RE-RECORDED COPY OF THE | | | NOC WILL BE REQUIRED BEFORE THE PERMIT | | | IS ISSUED. | | | | | | 2) THE EXTERIOR WALL SECTION ON SHEET 3 | | | SPECIFIES AN ARXX WALL SYSTEM (INSULATED | | | CONCRETE FORM). SUBMIT MANUFACTURER'S | | | SPECIFICATIONS AND INSTALLATION | | | INSTRUCTIONS FOR THE ICF SYSTEM. SUBMIT | | | WINDLOAD CALCULATIONS FOR THE SYSTEM | | | BASED ON 140 MPH WIND SPEED IN EXPOSURE | | | B. | | | | | | 3) THE ROOF SHEATHING NAILING PLAN ON | | | SHEET 3 DOES NOT INDICATE THAT THE | | | CORNERS OF THE FLAT ROOF ARE ZONE 3. | | | PLEASE CORRECT. SEE FBC FIGURE 1606.2(C) | | | | | | | | | 3) SPECIFY THE LINTELS OR BEAMS OVER | | | EXTERIOR WINDOW AND DOOR OPENINGS. | | | PROVIDE A LINTEL/BEAM SCHEDULE. | | | | | | 4) SPECIFY THE TYPE OF ANCHOR AND | | | MINIMUM EMBED FOR THE 3/4" BOLT THAT IS | | | SPECIFIED FOR THE CONNECTION OF THE | | | BRACES SUPPORTING THE PORCH ROOF. | | | | | | 5) PRODUCT APPROVALS SUBMITTED | | | WITH PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE | | | AT WWW.FLORIDABUILDING.ORG. PRODUCTS | | | WITH STATEWIDE APPROVAL ARE REQUIRED TO | | | BE SUBMITTED WITH A COVER SHEET THAT | | | LISTS THE PRODUCT IDENTITY NUMBER FROM | | | THE STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. | | | | | | 6) SUBMIT TWO COPIES OF PRODUCT | | | APPROVALS. | | | | | | 7) SUBMIT STATE/LOCAL PRODUCT APPROVALS | | | FOR THE FOLLOWING: | | | - SINGLE OUTSWING GLAZED FRENCH DOOR | | | - TRUSS ANCHORS | | | - TILE AND FLAT ROOF MATERIALS (OR A | | | SEPARATE PERMIT AND FEES WILL BE | | | REQUIRED) | | | | | | 8) THE FL NUMBERS LISTED ON SHEET 3 FOR | | | THE SIMPSON CONNECTORS ARE NOT CORRECT | | | FOR THE HETAL 20 ANCHORS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | - |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-12-22 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
j |
Date |
2004-12-21 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2004-12-22 00:00:00 | DENIED | | | | | | 1)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | | | | 2)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3) THE OWNER/AGENT IS REQUIRED TO SIGN | | | AND DATE THE ENERGY CALCULATION FORM PER | | | FBC CHAPTER 13. | | | | | | 4) CITY OF WPB AMENDMENTS TO FBC | | | 2111.1.9 REQUIRES A 1.5 INCH RECESS | | | WHERE EXTERIOR MASONRY WALLS BEAR ON A | | | CONCRETE FLOOR SURFACE. | | | | | | 5) FBC 1804.1.3 REQUIRES THE BOTTOM OF | | | FOOTERS TO BE A MINIMUM OF 12" BELOW | | | FINAL GRADE. SPECIFY ON PLANS. | | | | | | 6) SPECIFY THE TRUSS CONNECTORS ON THE | | | PLANS. | | | | | | 7) SPECIFY THE WINDOW SIZES ON THE | | | PLANS. | | | | | | 8) SPECIFY THE NEGATIVE AND POSITIVE | | | WINDLOAD PRESSURES FOR ALL EXTERIOR | | | WINDOW AND DOOR OPENINGS. | | | | | | 9) SAFETY GLAZING IS REQUIRED IN THE | | | BATHROOM WINDOW AND WINDOWS WITH THE 8" | | | SILL HEIGHT PER FBC 2405.2.1. | | | | | | 10) BEDROOM WINDOWS ARE REQUIRED TO | | | COMPLY WITH FBC 1005.4 FOR EMERGENCY | | | EGRESS. | | | | | | 11) GUTTER DOWNSPOUTS ARE REQUIRD TO | | | DISCHARGE AT LEAST 12" AWAY FROM THE | | | STRUCTURE PER FBC 1503.4.4. | | | | | | 12) SPECIFY ON THE PLAN THE SLOPE OF THE | | | BUILT UP FLAT ROOF. SEE FBC 1508.3.1 FOR | | | MINIMUM PITCHES. | | | | | | 13) SPECIFY THE LENGTH/EMBED DEPTH OF | | | THE 3/4" EXPANSION BOLTS FASTENING THE | | | TRUSS LEDGERS TO THE STRUCTURE. | | | | | | 14) THE ENERGY CALC. FORM LISTS A | | | CONCRETE ROOF DECK AND THE PLANS SPECIFY | | | A PLYWOOD DECK. PLEASE CORRECT. | | | | | | 15) FBC TABLE 600 IS USED TO DETERMINE | | | THE PERCENTAGE OF WALL AREA ALLOWED AS | | | OPENINGS BASED ON THE DISTANCE TO THE | | | PROPERTY LINE OR ASSUMED PROPERTY LINE | | | (WHEN TWO STRUCTURES ARE ON THE SAME | | | PROPERTY). SPECIFY THE LOCATION OF THE | | | ASSUMED PROPERTY LINE BETWEEN THE TWO | | | STRUCTURES BASED ON THE OPENINGS IN THE | | | EXISTING AND NEW STRUCTURES. | | | | | | 16) SUBMIT 2 COPIES OF ALL PRODUCT | | | APPROVALS. | | | | | | 17) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. | | | WWW.FLORIDABUILDING.ORG | | | | | | 18) SUBMIT STATE/LOCAL PRODUCT APPROVALS | | | FOR THE FOLLOWING: | | | - ROOFING (OR SEPARATE PERMIT WILL BE | | | REQUIRED) | | | - TRUSS CONNECTORS | | | - OUTSWING GLAZED DOORS (SINGLE AND | | | DOUBLE WITH AND WITHOUT SIDELITES) | | | | | | 19) SUBMIT A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS. SPECIFY | | | THE FASTENERS, SPACING AND MOUNT TYPE | | | THAT WILL BE USED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-11-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-11-14 |
Time |
14:47 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-11-14 |
Time |
14:47 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-11-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-11-06 |
Time |
15:31 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2005-11-06 |
Time |
15:30 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-12-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2004-12-10 |
Time |
14:00 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2004-12-10 |
Time |
14:00 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-07-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-27 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-27 |
Time |
08:05 |
Sent To |
M |
|
| Notes |
| 2006-07-27 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-06-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-26 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-26 |
Time |
11:08 |
Sent To |
B |
|
| Notes |
| 2006-06-26 00:00:00 | TO "RMCDOUGAL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-12-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-29 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-29 |
Time |
11:24 |
Sent To |
P |
|
| Notes |
| 2005-12-29 00:00:00 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-10-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-21 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-21 |
Time |
11:00 |
Sent To |
E |
|
| Notes |
| 2005-10-21 00:00:00 | TO "JLEAHY" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-10-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-04 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-04 |
Time |
15:47 |
Sent To |
Z |
|
| Notes |
| 2005-10-04 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-12-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-17 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-17 |
Time |
16:20 |
Sent To |
B |
|
| Notes |
| 2004-12-17 00:00:00 | SENT TO "RES" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-06 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-06 |
Time |
10:57 |
Sent To |
E |
|
| Notes |
| 2004-12-06 00:00:00 | SENT TO "E" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-08 |
Time |
14:40 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-08-08 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2006-08-08 00:00:00 | REVISION TO MECANICAL PLANS, E-CAL'S, | | | AND MANUAL J. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-07-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-28 |
Time |
12:06 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-07-28 |
Time |
12:06 |
Sent To |
B |
|
| Notes |
| 2006-07-28 00:00:00 | *** DENIED *** | | | 1) AS NOTED IN LAST REVIEW, MECHANICAL | | | PLANS NEED TO BE REVISED | | | TO SHOW CHANGES TO A/C EQUIPMENT TO | | | COINCIDE WITH NEW ENERGY CAL'S. AND NEW | | | MANUAL J CAL'S. | | | | | | 2) PLANS THAT WERE SUBMITTED WERE | | | BUILDING PLANS, PLEASE REVISE MECHANICAL | | | PLANS PAGE M-1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-27 |
Time |
09:55 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-06-27 |
Time |
09:55 |
Sent To |
B |
|
| Notes |
| 2006-06-27 00:00:00 | *** DENIED *** | | | 1) MECHANICAL PLANS NEED TO BE REVISED | | | TO SHOW CHANGES TO A/C EQUIPMENT TO | | | COINCIDE WITH NEW ENERGY CAL'S. AND NEW | | | MANUAL J CAL'S. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-12-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2004-12-15 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2004-12-15 |
Time |
10:52 |
Sent To |
P |
|
| Notes |
| 2004-12-15 00:00:00 | REFER TO SECTION 610.ABC.3.5.2 AIR | | | HANDLING UNITS.FLORIDA ENERGY CODE.AIR | | | HANDLING UNIT MUST BE WITHIN 6FT.OF | | | ATTIC ACCESS.PLAN REVIEW BY HAROLD | | | MOSER | | | (561)805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-08-01 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-08-01 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2006-08-01 00:00:00 | REVISED SHEET RESTAMPED FOR PLUMBING. NO | | | PLUMBING CHANGES. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-01-03 |
Time |
09:13 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2006-01-03 |
Time |
09:13 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-11-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-11-15 |
Time |
18:13 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-11-15 |
Time |
18:13 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-12-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-16 |
Time |
12:40 |
Rev Time |
0.95 |
| Received By |
kstevens |
Date |
2004-12-16 |
Time |
12:40 |
Sent To |
Z |
|
| Notes |
| 2004-12-16 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT MEET | | | CODE REQUIREMENTS, NOR DOES IT REFLECT | | | THE FLOOR PLAN. | | | A) DISHWASHER SHALL NOT CONNECT TO THE | | | BUILDING SANT. DRAIN. IT SHALL BE TIED | | | INTO THE TAILPIECE OF THE KITCHEN SINK | | | DRAIN UPSTREAM OF THE TRAP FOR THE | | | SINK. | | | B) THE WASH MACHINE IS NOT SHOWN ON THE | | | SANT. RISER DIAGRAM, A STANDPIPE IS | | | REQUIRED AND A CLEANOUT IS REQUIRED 4' | | | ABOVE THE FLOOR FOR ACCESS. SECTIONS | | | 104.2.1, 1002.1, 708.10. | | | C) THE BATHTUB REQUIRES A TRAP AND IS | | | NOT VENTED PIPED AS SHOWN, SECTION 902.1 | | | AND 1002.1. | | | D) TWO DISHWASHERS ARE SHOWN ON THE | | | SANT. RISER DIAGRAM. | | | 2) SEE ATTACHED SHEET FOR AN EXAMPLE OF | | | A SANT. RISER THAT MEETS CODE REQ. AND | | | REFLECT THE FLOOR PLAN. | | | 3)THE PERSONAL SIGNATUREAND THE DATE | | | THE PLANS ARE SIGNED AND SEALED ARE | | | REQUIRED. INITIALS ARE NOT ACCEPTABLE. | | | FAC 61G1-16.003, FS 481,2055. THIS IS | | | REQUIRED ON ALL SHEETS. | | | 4) A CERTIFICATE OF AUTHORIZATION IS | | | REQUIRED ON THE TITLE BLOCK PER FAC | | | 61G1-16.004(2) (FIRM LICENSE NUMBER) AND | | | FS 481.219 - THIS IS REQUIRED ON ALL | | | SHEETS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2005-10-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-10-18 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-10-18 |
Time |
16:23 |
Sent To |
I |
|
| Notes |
| 2005-10-18 00:00:00 | ZONING APPROVED 12/1704, NOTHING HAS | | | CHANGED, OWNER IS JUST ADDRESSING | | | COMMENTS FROM STRUCTURAL & PLUMBING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-12-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-12-17 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-12-17 |
Time |
15:13 |
Sent To |
I |
|
| Notes |
|
|