Plan Review Details - Permit 04120081
Plan Review Stops For Permit 04120081
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-01-20 Cont ID  
Sent By alange Date 2006-01-20 Time 08:12 Rev Time 0.00
Received By alange Date 2006-01-20 Time 08:12 Sent To  
Notes
2006-01-20 00:00:00RESTAMP OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-09-29 Cont ID  
Sent By alange Date 2005-09-29 Time 16:52 Rev Time 0.50
Received By alange Date 2005-09-29 Time 16:42 Sent To  
Notes
2005-09-29 00:00:00STRUCTURAL REV OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-03-08 Cont ID  
Sent By alange Date 2005-03-08 Time 09:08 Rev Time 0.75
Received By alange Date 2005-03-08 Time 08:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-12-30 Cont ID  
Sent By alange Date 2004-12-30 Time 15:33 Rev Time 1.66
Received By alange Date 2004-12-30 Time 15:29 Sent To  
Notes
2005-01-03 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
  
 2. BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SUBMIT TWO COPIES OF PRODUCT
 APPROVALS FOR STRAPS AND TIE-DOWNS.
 ALL PRODUCT APPROVALS REQUIRE THE
 FOLLOWING.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 4. BASED ON SBCCI BUILDING VALUATION
 DATA THE BUILDING VALUE HAS BEEN
 ADJUSTED TO $44,252.ADDITIONAL PERMIT
 FEES ARE DUE.
 575 SQ.FT. X $76.96 = $44,252
  
 5.PLEASE SHOW HOW SMOKE DETECTORS AND
 GFCI OUTLETS WILL COMPLY WITH FBC
 3401.7.1.2.1
  
 6.EXISTING BEDROOM ADJACENT TO ROOM
 ADDITION. SHOW WINDOW SIZE COPMLYING
 WITH FBC 1005.4
  
 7.STRUCTURAL NOTE #11 AND PLYWOOD
 SHEATHING NAILING SCHEDULE CONFLICT.
 SHOW SHEATHING NAILING SCHEDULE
 COMPLYING WITH FBC 2306.1 WEST PALM
 BEACH AMMENDMENTS
  
 8.SHOW SIZE AND LOCATION OF ATTIC
 ACCESS COMPLYING WITH FBC 2309.6
  
 9. SAFTEY GLAZING AT TUB AND SHOWER AREA
 IS REQUIRED.FBC 2405.2.1
  
 10. PRINTED NAME AND SIGNATURE OF PERSON
 RESPOSIBLE FOR THE DESIGN REQUIRED ON
 EACH SHEET.STAMPED NAME AND SIGNATURE
 IS NOT ACCEPTABLE. FBC 104.2.1
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2005-02-25 Cont ID  
Sent By btrobaug Date 2005-02-25 Time 13:12 Rev Time 0.00
Received By btrobaug Date 2005-02-25 Time 13:12 Sent To M
Notes
2005-02-25 00:00:00 
 SENT TO ELECTRICAL IN ERROR, SHOULD HAVE
 WENT TO MECH./WRT.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-02-17 Cont ID  
Sent By btrobaug Date 2005-02-17 Time 15:08 Rev Time 0.33
Received By btrobaug Date 2005-02-17 Time 14:37 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-12-17 Cont ID  
Sent By btrobaug Date 2004-12-17 Time 15:16 Rev Time 0.50
Received By btrobaug Date 2004-12-17 Time 14:28 Sent To P
Notes
2004-12-17 00:00:00 
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE INDICATE IF THE ELECTRICAL
 SERVICE IS NEW AND PART OF THE SCOPE OF
 THIS APPLICATION. IF SO ADD TO
 DESCRIPTION ON APPLICATION.
  
 2} INDICATE THE SIZE OF THE GEC.INDICATE
 THE GROUNDING SYSTEM IN COMPLIANCE WITH
 250.52 ALL, IF NEW SERVICE.
  
 3} THE BATH CIRCUIT MUST COMPLY WITH
 210.11(C)(3). 20AMP WITH #12 WIRE.
  
 4} PLEASE NOTE THAT PER CHAPTER 34 OF
 THE FLORIDA BLDG CODE, SMOKE DETECTORS
 AND GFI'S MUST BE BROUGHT TO CURRENT
 CODE.
  
 5} INCREASE THE VALUATION ON THE
 APPLICATION PER 104.6.5.FBC PRIOR TO
 RESUBMITTING ANY PLANS.
  
  
  
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-01-13 Cont ID  
Sent By adarroug Date 2006-01-13 Time 10:57 Rev Time 0.00
Received By adarroug Date 2006-01-13 Time 10:57 Sent To B
Notes
2006-01-13 00:00:00TO "ALANGE" DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-09-22 Cont ID  
Sent By adarroug Date 2005-09-22 Time 13:49 Rev Time 0.00
Received By adarroug Date 2005-09-22 Time 13:49 Sent To B
Notes
2005-09-22 00:00:00TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-02-10 Cont ID  
Sent By adarroug Date 2005-02-10 Time 13:34 Rev Time 0.00
Received By adarroug Date 2005-02-10 Time 13:34 Sent To E
Notes
2005-02-10 00:00:00TO BTROBAUG DESK/RESUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-12-14 Cont ID  
Sent By mjacobs Date 2004-12-14 Time 08:32 Rev Time 0.00
Received By mjacobs Date 2004-12-14 Time 08:32 Sent To E
Notes
2004-12-14 00:00:00SENT TO "E" BOX.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-12-03 Cont ID  
Sent By mjacobs Date 2004-12-03 Time 13:54 Rev Time 0.00
Received By mjacobs Date 2004-12-03 Time 13:54 Sent To Z
Notes
2004-12-03 00:00:00SENT TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-02-28 Cont ID  
Sent By prafter Date 2005-02-28 Time P Rev Time 0.45
Received By prafter Date 2005-02-28 Time 12:04 Sent To B
Notes
2005-02-28 00:00:00SECOND MECH. REVIEW SATIFIED ALL
 PREVIOUS QUESTIONS.
  
 PAT RAFTER 561/805/6728 OR 805/6719.
 PLEASE CALL IF THEAR ANY QUESTIONS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-12-29 Cont ID  
Sent By prafter Date 2004-12-29 Time 09:11 Rev Time 45.00
Received By prafter Date 2004-12-29 Time 08:19 Sent To B
Notes
2004-12-29 00:00:001.A/C CONDENSING UNIT NOT REFLECTED
 ON PLAN .
 2.DYER VENT NOT REFLECTED ON PLAN .
 3.CONDENSATE MUST BE REFLECTED ON
 A/C
 PLAN .
 4.PERMIT VALUE MUST REFLECT ALL
 LABOR
 AND MATERIALS FOR ALLTRADES .
  
 PAT RAFTER 805/6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-02-23 Cont ID  
Sent By jleech Date 2005-02-23 Time 16:38 Rev Time 0.33
Received By jleech Date 2005-02-23 Time 16:38 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-12-23 Cont ID  
Sent By btrobaug Date 2004-12-23 Time 15:17 Rev Time 0.33
Received By kstevens Date 2004-12-23 Time 05:01 Sent To M
Notes
2004-12-23 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
  
 1) SECTION 104.2.1 PRINTED NAME AND
 SIGNATURE OF PERSON RESPONSIBLE FOR THE
 DESIGN REQUIRED ON EACH SHEET. STAMPED
 NAME FOR SIGNATURE IS NOT ACCEPTABLE.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-12-13 Cont ID  
Sent By mmclean Date 2004-12-13 Time 14:52 Rev Time 0.00
Received By mmclean Date 2004-12-13 Time 14:52 Sent To I
Notes
***NONE***