| Plan Review Stops For Permit 04111429 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2006-08-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-08-31 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2006-08-31 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2006-08-31 00:00:00 | REVISION CEILING ABOVE SALAD BAR |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-06-27 |
Time |
07:53 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-06-27 |
Time |
07:53 |
Sent To |
PC |
|
| Notes |
| 2006-06-27 00:00:00 | REVISION FRONT ENTRY DOORS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-06-22 |
Time |
08:44 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-06-22 |
Time |
08:44 |
Sent To |
ENG |
|
| Notes |
| 2006-06-22 00:00:00 | PERMIT: 04111429 | | | ADD: 1900 PALM BCH LAKES | | | CONT: SHANE JOHN ALLEN | | | TEL: (585)509-1980 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW: REVISION DATED 6/13/06 | | | TRASH DUPSTER ENCLOSURE | | | ACTION: DENIED | | | | | | | | | 1) PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 2) 61G1-16.004FL. ADMIN. CODE.PLANS | | | PREPARED BY A REGISTERED ARCHITECT SHALL | | | INCLUDE A TITLE BLOCK WHICH MUST: | | | - STATE THE FIRM NAME, ADDRESS AND | | | TELEPHONE NUMBER | | | - STATE THE FIRM LICENSE NUMBER | | | - STATE PROJECT NAME OR IDENTIFICATION | | | - STATE DATE PREPARED | | | - INCLUDE AN ORIGINAL SIGNATURE AND | | | DATED SEAL | | | - INCLUDE THE PRINTED NAME OF THE | | | ARCHITECT SEALING THE PLANS | | | | | | 3) 481.219 F.S.CERTIFICATE OF | | | AUTHORIZATION.THE TITLE BLOCK FOR ANY | | | SHEET BEARING THE NAME OF AN ARCHITECT | | | PRACTICING UNDER A FICTITIOUS NAME, A | | | CORPORATION, OR A PARTNERSHIP, OFFERING | | | ARCHITECTURAL SERVICES, SHALL INCLUDE | | | THE CERTIFICATE OF AUTHORIZATION | | | NUMBER.ADD THE NUMBER TO EACH SHEET. | | | THIS MAY BE ADDED BY HAND. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-06-21 |
Time |
09:29 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-06-21 |
Time |
09:29 |
Sent To |
PC |
|
| Notes |
| 2006-06-21 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04111429 | | | ADD: 1900 PALM BCH LAKES | | | CONT: SHANE JOHN ALLEN | | | TEL: (585)509-1980 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW: REVISION DATED 6/13/06 | | | ACTION: DENIED | | | | | | | | | 1) PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 2) 61G1-16.004FL. ADMIN. CODE.PLANS | | | PREPARED BY A REGISTERED ARCHITECT SHALL | | | INCLUDE A TITLE BLOCK WHICH MUST: | | | - STATE THE FIRM NAME, ADDRESS AND | | | TELEPHONE NUMBER | | | - STATE THE FIRM LICENSE NUMBER | | | - STATE PROJECT NAME OR IDENTIFICATION | | | - STATE DATE PREPARED | | | - INCLUDE AN ORIGINAL SIGNATURE AND | | | DATED SEAL | | | - INCLUDE THE PRINTED NAME OF THE | | | ARCHITECT SEALING THE PLANS | | | | | | 3) 481.219 F.S.CERTIFICATE OF | | | AUTHORIZATION.THE TITLE BLOCK FOR ANY | | | SHEET BEARING THE NAME OF AN ARCHITECT | | | PRACTICING UNDER A FICTITIOUS NAME, A | | | CORPORATION, OR A PARTNERSHIP, OFFERING | | | ARCHITECTURAL SERVICES, SHALL INCLUDE | | | THE CERTIFICATE OF AUTHORIZATION | | | NUMBER.ADD THE NUMBER TO EACH SHEET. | | | THIS MAY BE ADDED BY HAND. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-11-10 |
Time |
12:39 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-11-10 |
Time |
12:39 |
Sent To |
PC |
|
| Notes |
| 2005-11-10 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04111429 | | | ADD: 1900 PALM BCH LAKES | | | CONT: SHANE JOHN ALLEN | | | TEL: (585)509-1980 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW: | | | ACTION: DENIED | | | | | | PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-30 |
Time |
20:11 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2005-06-30 |
Time |
20:11 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-05-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-05-31 |
Time |
15:17 |
Rev Time |
4.40 |
| Received By |
jwitmer |
Date |
2005-05-31 |
Time |
12:10 |
Sent To |
|
|
| Notes |
| 2005-05-31 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04111429 | | | ADD: 1900 PALM BEACH LAKES BLVD | | | CONT:SHAH, DROTOS & ASSOC | | | TEL: (954)943-9433 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)THIRD REQUEST NUMBER 2 FROM THE | | | PREVIOUS REVIEW. THIS PROJECT IS LOCATED | | | IN A QUESTIONABLE SOILS ZONE. THE | | | STRUCTURAL ENGINEER MAY DESIGN THE | | | BUILDING TO PERFORM TO A MINIMUM SAFE | | | BEARING CAPACITY BUT HOW DOES HE KNOW | | | WHAT THAT CAPACITY IS? PROVIDE THE | | | FOLLOWING SOILS INFORMATION; | | | FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITLY KNOWN OR IS IN QUESTION | | | THE BUILDING OFFICIAL MAY REQUIRE EXPLOR | | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | | TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA. | | | | | | 3) BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-03-02 |
Time |
07:00 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2005-03-02 |
Time |
06:59 |
Sent To |
|
|
| Notes |
| 2005-03-02 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04111429 | | | ADD: 1900 PALM BEACH LAKES BLVD | | | CONT:SHAH, DROTOS & ASSOC | | | TEL: (954)943-9433 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)SECOND REQUEST NUMBER 2 FROM THE | | | PREVIOUS REVIEW. THIS PROJECT IS LOCATED | | | IN A QUESTIONABLE SOILS ZONE. THE | | | STRUCTURAL ENGINEER MAY DESIGN THE | | | BUILDING TO PERFORM TO A MINIMUM SAFE | | | BEARING CAPACITY BUT HOW DOES HE KNOW | | | WHAT THAT CAPACITY IS? PROVIDE THE | | | FOLLOWING SOILS INFORMATION; | | | FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITLY KNOWN OR IS IN QUESTION | | | THE BUILDING OFFICIAL MAY REQUIRE EXPLOR | | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | | TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA. | | | | | | 3) SECOND REQUEST NUMBER 3 FORM THE | | | PREVIOUS REVIEW, THE RESPONSE WAS | | | ,PLEASE REFER TO ENERGY CALCULATIONS AND | | | REPORT FROM THE MECANICAL ENGINEER. NO | | | ENERGY CALCUALTIONS NOR REPORT | | | SUBMITTED. | | | FL BLD CODE CHAP 13 ENERGY EFFICENCY | | | PROVIDE ENERGY CALS/ W MANUAL "J". | | | | | | 4) SECOND REQUEST, COMMENT # 4 FROM THE | | | PREVIOUS REVIEW DEALS WITH SIGNED & | | | SEALED PLANS, REPORTS ( STRUCTURAL | | | CALCULATIONS) TRUE WHILE PLANS DO NOT | | | NEED TO BE SEALED FOR PLAN REVIEW, IF | | | PLANS ARE PERMIT READY ALL THE DESIGN | | | PROFESSIONAL WILL COME INTO CITY HALL | | | TO SIGN AND SEAL (RAISED) PLANS. PLANS | | | IF READY FOR PERMIT DO NOT GET STAMPED | | | UNTIL ALL FEES ARE PAID AND IMPACT FEES | | | PAID TO THE COUNTY. | | | PLANS, SPECIFICATIONS,REPORTS OR OTHER | | | DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 5) SECOND REQUEST, COMMENTNUMBER 5 | | | FROM THE PREVIOUS REVIEW, DEALS WITH | | | TYPE VI CONSTRUCTION IN THE FIRE ZONE, | | | RESPONSE BUILDING TYPE IS TYPE V-B. THIS | | | | | | MAY BE A BUILDING TYPE IN THE IBC BUT IT | | | ISN'T IN THE 2001 FLORIDA BUILDING CODE. | | | CORRECT ON THE CODE COMPLIANCE SHEET | | | T1.1 AND ON S701 DETAIL (2) THE WORDING | | | "FIREPROOF PLYWOOD" PROVIDE | | | DOCUMENTATION OF "FIREPROOF PLYWOOD" | | | MEETING THE REQUIREMENTS OF ASTM 136 OR | | | ASTM E 84.I BELIEVE THE TERM SHOULD BE | | | | | | "FIRE RETARDENT TREATED". | | | | | | 6) SECOND REQUEST DEALS WITH IN THE | | | CORRECTION OF THE ABOVE CODE COMPLIANCE | | | LISTED ABOVE, TYPE V, UNSPRINKLERED NOT | | | "B". | | | | | | 7) SECOND REQUEST, COMMENT 10 FROM THE | | | PREVIOUS REVIEW, DEALS WITH DOOR # 100, | | | THE PRODUCT APPROVAL SUBMITTED IS FOR A | | | SERIES "2000 O-SX-SX-O ALUMINIUM | | | AUTOMATIC SLIDING GLASS DOOR SYSTEM W/ | | | BREAKOUT. THE DOOR SCHEDULE EVEN HAS THE | | | | | | NOA FOR THE ABOVE MENTIONED, BUT IN WOOD | | | NOT ALUMINIUM, EXPLAIN. | | | 7B) RESPONSE ALSO INDICATES THAT THE | | | DOOR WILL BE FITTED WITH PANIC HARDWARE, | | | HOW WILL THIS BE ACCOMPLISHED WITH THE | | | HORIZONTAL SLIDING MOTION? | | | | | | 8)SECOND REQUEST,COMMENT # 15 FROM THE | | | PREVIOUS REVIEW, 1606.2.4 MAIN FORCE | | | RESISTING SYSTEM, DOES NOT INDICATE A | | | ROOF FRAMING PLAN AND TRUSS ANCHOR | | | SCHEDULE INDICATING THE POSITIVE AND | | | NEGATIVE AND HORIZONTAL FORCES ACTING | | | AGAINST THE TRUSSES. RESPONSE REFER TO | | | ATTACHED RESPONCE FROM THE STRUCTURAL | | | ENGINEER. AGAIN NO RESPONSE, NO | | | INFORMATION? | | | | | | 9) SECOND REQUEST, COMMENT 16 FROM THE | | | PREVIOUS REVIEW, 1707.3.1 JOIST | | | HANGERS, FRAMING ANCHORS & SIMILAR | | | DEVICES SHALL BE TEST- ED IN ACCORDANCE | | | W/ ASTM D 1761 & BE LABELED AND LISTED | | | FOR THEIR LOAD CARRY- ING CAPACITY. | | | THE RESPOSE: SEE ATTACHED RESPONSE FROM | | | STRUCURAL ENGINEER, AGAIN NO RESPONSE, | | | NO INFORMATION? | | | | | | 10) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS- (2) DIRRENT NOA WERE | | | SUBMITTED FOR STOREFRONT WINDOWS FOR | | | ARCH,(1) NOA 01-0619.01 FOR INTERIOR | | | GLAZED UNITS (2) NOA 03-1211.08 FOR | | | INTERIOR OR OUTSIDE GLAZED UNITS. WHICH | | | WILL BE USED IF BOTH PROVIDE A SCHEDULE | | | FOR VARIFICATION. | | | B)MULLIONS: DEPENDING ON THE ABOVE | | | INFORMATION | | | SEPERATE MULLION REPORTS MAY BE | | | REQUIRED. | | | C) MISSING PRODUCT INFORMATION FOR A | | | AUTOMATIC WOOD SLIDING ENTRY DOOR W/ | | | BREAKAWAY DOOR | | | H) ROOFING REPORTS: J. M. METALS SEE | | | NOA REQUIREMENTS FOR A OR B FIRE RATING | | | REQUIREMENTS ( REFER TO ORIGINAL COMMENT | | | | | | NUMBER ((7) FBC* F102.2.4ROOF | | | COVERINGS, ON BUILDINGS LOCATED IN THE | | | FIRE DISTRICT, SHALL CONFORM TO THE | | | REQUIREMENTS OF CLASS A OR B ROOF | | | COVERINGS, AS DEFINED IN FBC 1505. | | | ANNOTATE THE PLANS TO DEMONSTRATE | | | COMPLIANCE.) NOA UNDER APPROVED SYSTEMS | | | FIRE BARRIER BOARD SEE WHAT ADDITIONAL | | | MATERIALS THAT CAN BE APPROVED TO MAKE | | | AN APPROVED FIRE BARRIER. | | | | | | 11) BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-12-15 |
Time |
12:54 |
Rev Time |
5.50 |
| Received By |
jwitmer |
Date |
2004-12-15 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2004-12-15 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT:04111429 | | | ADD:1900 PALM BCH LAKES BLVD | | | CONT:***PLAN REVIEW*** | | | SHAH DROTOS & ASSOC | | | TEL: (954)943-9433 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: | | | | | | 1) BEFOREA PERMIT CAN BE ISSUED A | | | RECORDEDNOTICE OF COMMENCEMENT WILL | | | BE | | | REQUIRED. | | | | | | 2)FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITLY KNOWN OR IS IN | | | QUESTION | | | THE BUILDING OFFICIAL MAY REQUIRE | | | EXPLOR | | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | | TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA. | | | | | | 3) FL BLD CODE CHAP 13 ENERGY EFFICENCY | | | PROVIDE ENERGY CALS/ W MANUAL "J" | | | | | | 4) FOR PLANS SUBMITTED UNDER"PERMIT | | | SET" | | | PLANS, SPECIFICATIONS,REPORTS OR OTHER | | | DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 5) SITE IS LOCATED IN A "FIRE | | | DISTRICT", | | | F102.1 NO TYPE VI CONSTRUCTION ALLOWED | | | SEES701 DETAIL (2) EXTERIOR WALL OUT | | | OF COMBUSTIBLES. | | | | | | 6 ) FBC* F102.2.8PERMANENT CANOPIES/ | | | AWNINGS AND THEIR SUPPORTS, ON | | | BUILDINGS | | | LOCATED IN THE FIRE DISTRICT, SHALL BE | | | OF NON-COMBUSTIBLE MATERIAL, FIRE | | | RETARDANT TREATED WOOD, WOOD OF TYPE | | | III | | | SIZES OR OF 1-HOUR RESISTANT | | | CONSTRUCTION.ANNOTATE THE PLANS TO | | | DEMONSTRATE COMPLIANCE. | | | | | | 7 ) FBC* F102.2.4ROOF COVERINGS, ON | | | BUILDINGS LOCATED IN THE FIRE DISTRICT, | | | SHALL CONFORM TO THE REQUIREMENTS OF | | | CLASS A OR B ROOF COVERINGS, AS DEFINED | | | IN FBC 1505.ANNOTATE THE PLANS TO | | | DEMONSTRATE COMPLIANCE. | | | | | | 8) FBC* F102.2.7ARCHITECTURAL TRIM, | | | ON | | | BUILDINGS LOCATED IN THE FIRE DISTRICT, | | | SHALL BE CONSTRUCTED OF APPROVED | | | NON-COMBUSTIBLE MATERIALS OR FIRE | | | RETARDANT TREATED WOOD.ANNOTATE THE | | | PLANS TO DEMONSTRATE COMPLIANCE. | | | | | | 9) CORRECTION OF GENERAL NOTES & CODE | | | COMPLIANCE, CONSTRUCTION TYPE: | | | TYPE V UNSPRINKLERED NOT "B" | | | | | | 10) DOOR # 100 PROVIDE INFORMATION ON | | | THIS BEING A ACCESSIBLE DOOR AS WELL AS | | | A FIRE EXIT. THIS DOOR APPEARS TO BE A | | | HORIZONTAL SLIDING DOOR, IS THIS POWER | | | ACTIVATED? SEE 1012.4. | | | | | | 11) CE-3 SOUTH WALL OF BLDG IS LOCATED | | | AT 15'-0" FROM PROPERTY LINE, 705.1.1.2 | | | OPENING PROTECTIVES, EVERY WALL WITHIN | | | 15'-0" OF A PROPERTY LINE SHALL BE | | | EQUIPPED WITH APPROVED OPENING | | | PROTECTIVES. | | | | | | 12) A4.0 DETAILS 1& 2 TO COMPLY WITH: | | | 2111.1.9*PROVIDE A 1 1/2" RECESS | | | FOR A WATERSTOP. FLOOR/ WALL. | | | | | | 13) CORRECT BASES OF DESIGN UNDERS101 | | | A) 2001 FLORIDA BUILDING CODE | | | B) WIND EXPOSURE "B" IF DESIGNED TO | | | "C" HIGHER WIND PRESSURES WILL BE | | | TAKEN. | | | | | | 14) LOCAL AMENMENTS FOR ROOF SHEATHING: | | | TABLE 2306.1 PALM BEACH COUNTY | | | AMENDMENTS | | | ROOF SHEATHING NAILING REQUIREMENTS | | | | | | ZONE 1 & 28D COMMON | | | 6" EDGES & 6" INTERMEDIATES | | | | | | ZONE 38DCOMMON | | | 4" EDGES & 6" INTERMEDIATES | | | | | | 15) 1606.2.4 MAIN WIND FORCE RESISTING | | | SYSTEM- PLANS DO NOT INDICATE A ROOF | | | FRAMING PLAN AND TRUSS ANCHOR SCHEDULE | | | INDICATING THE POSITIVE , NEGATIVE AND | | | HORIZONTAL FORCES ACTING AGAINST THE | | | TRUSSES. | | | | | | 16) 1707.3.1 JOIST HANGERS, FRAMING | | | ANCHORS & SIMILAR DEVICES SHALL BE | | | TEST- | | | ED IN ACCORDANCE W/ ASTM D 1761 & BE | | | LABELED AND LISTED FOR THEIR LOAD | | | CARRY- | | | ING CAPACITY. | | | | | | 17)FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS | | | B) MULLIONS | | | C) EXTERIOR GLAZED DOORS | | | D) TRANSOMS | | | E) STORM SHUTTERS/ IF LARGE MISSLE | | | | | | GLAZING IS NOT USED | | | F) ROOFING ASSEMBLIES | | | G) TRUSS ANCHORS | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 18)PROVIDE STORM PANEL INFORMATION WITH | | | INSTALLATION SCHEDULE AND KEY PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE | | | USED | | | FOR ALL NON-IMPACT GLAZING.FBC | | | 1606.1.4. | | | | | | 19)FL BLD CODE 2001 SECTION 103.6, | | | 1606.1.4, 1707.4 & 3401.7.2.4. | | | PROCEDURES: 1(B) A COMPLETE | | | INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL | | | PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | | | | 20)1707.4.5.1 MULLIONS OCCURRING | | | BETWEEN | | | INDIVIDUAL WINDOW AND GLASS | | | DOOR ASSEMBLIES. TESTING REPORTS ARE | | | REQUIRED BY AN APPROVED TESTING | | | LABORATORY OR BE ENGINEERED. | | | | | | 21)1707.4.5.2 MULLIONS SHALL BE DESIGN- | | | ED TO TRANSFER THE DESIGN PRESSURE | | | LOADS | | | APPLIED BY THE WINDOW OR DOOR | | | ASSEMBLIES | | | TO THE ROUGH OPENING SUBTRATE. | | | | | | 22) 1707.4.3 EACH EXTERIOR DOOR | | | ASSEMBLY | | | NOT COVERED BY 1707.4.2 | | | (GLAZED DOORS) SHALL BE LISTED AND | | | TEST- | | | ED FOR A PERIOD EQUAL TO THE QUANITY | | | 3600/ V WHERE THE TIME PERIOD IS IN | | | SECTIONS AND V IS IN MILES PER HR TAKEN | | | FROM FIGURE 1606. THE TIME PERIOD SHALL | | | ALSO INCLUDE A 10 SECOND PERIOD AT A | | | LOAD EQUAL TO 1.5 TIMES THE DESIGN | | | PRESSURE. DADE COUNTY & SBCCI REPORTS | | | ARE ACCEPTED. | | | | | | 23) 1204.2 SURROUNDING MATERIALS; | | | THE WALLS & FLOORS OF ALL PUBLIC REST- | | | ROOMS SHALL BE LINED WITH NONABSORBANT | | | MATERIALS TO A HEIGTH OF 4'-0" ABOVE THE | | | FLOOR. | | | 24) SHEET M-2 INDICATES ROOF TOP UNITS: | | | 1511.7 ROOF MOUNTED MECHANICAL UNIT S | | | SHALL BE MOUNTED ON CURBS RAISED A | | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. | | | MECH. 301.13 WIND RESISTANCE MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUP PORTS THAT | | | ARE EXPOSED TO WIND SHALL BE DESIGNED | | | AND INSTALLED TO RESIST THE WIND | | | PRESSURES ON THE EQUIPMENT & THE | | | SUPPORTS AS DETERMINED IN ACCORDANCE | | | WITH THE FL BLD CODE. THIS MAY BE ACCOMP | | | LISHED BY DESIGN OR BY APPLICATION OF | | | SECTION 301.13.1. | | | | | | 25)1503.4.4 PROTECTION AGAINST DECAY & | | | TERMITES. CONDENSATE LINES & ROOF DOWN | | | SPOUTS SHALL DISCHARGE AT LEAST 1 FT. | | | AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EX- | | | TENSIONS, OR SPLASH BLOCKS. | | | | | | 26)1503.4.2 OVERFLOW DRAINS SHALL BE THE | | | SAME SIZE AS ROOF DRAINS, INSTALLED WITH | | | THE INLET FLOW LINE LOCATED 2" ABOVE THE | | | LOWEST POINT OF THE ROOF LINE. OVERFLOW | | | SCUPPERS SHALL BE A MINIMUM OF 4"IN | | | HEIGTH AND SHALL BE PLACED IN WALLS OR | | | PARARETS WITH THE INLET FLOW LINE | | | NOT LESS THAN 2" ABOVE THE ROOF | | | SURFACE. | | | | | | 27)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | THE EXISTING BUILDING WILL BE | | | DEMOLISHED, REQUIRE A CERTIFICATE OF | | | COMPLETION FOR THE DEMOLITION WORK. IN | | | DOING THIS YOU SHALL RECEIVE A CREDIT AT | | | TIME OF IMPACT FEE ASSESSMENT. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-08-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-15 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-15 |
Time |
13:51 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-30 |
Time |
18:28 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-06-30 |
Time |
18:22 |
Sent To |
|
|
| Notes |
| 2005-06-30 00:00:00 | PLANS STILL ONLY SUBMITTED AS "PLAN | | | REVIEW" AND NOT SUBMITTED FOR PERMIT. | | | | | | | | | ELECTRICAL PLANS OK, STAMPED TWO SETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-05-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-10 |
Time |
11:34 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2005-05-10 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2005-05-10 00:00:00 | ******** UNSAT 3RDREVIEW******** | | | | | | ** SWEET TOMATOES** | | | PLANS SUBMITTED FOR PLAN REVIEW ONLY. | | | NOT SUBMITTED FOR PERMIT AT THIS TIME. | | | | | | PLEASE SEE SOME OF THE COMMENTS FROM | | | PREVIOUS TWO REVIEWS STILL NEED TO BE | | | ADDRESSED. | | | PLEASE SEE NOTES #'S: | | | 2,8,AND 9. | | | | | | 2)NOTE: NOTE#2 NO, PLEASE SEE TITLE | | | BLOCKS FOR ARCHITECTUAL FIRM STILL DOES | | | NOT CONTAIN THE REQUIRED LICENSE | | | INFORMAION AS REQUIRED UNDER FAC | | | 61G1-16.004 AS "REQUIRED" PER "FLORIDA | | | STATUES". FS 481.219 | | | PLEASE SEE THIS INFORMATION IS REQUIRED | | | FOR ALL SHEETS AND FOR ALL TRADES | | | WHEATHER OR NOT COMMENTS ARE MADE BY | | | OTHER REVIEWER(S). | | | PLEASE SEE A -SHEETS, S- SHEETS ETC. | | | | | | 8)NOTE: NOTE#8 NO, PLEASE SEE RECEPTS | | | HAVE NOW BEEN ADDED AND ARE OK, HOWEVER | | | THESE WERE ADDED"BELOW" WINDOWS. | | | PLEASE SEE THESE ARE REQUIRED "ABOVE" | | | WINDOWS AS SHOWN. | | | 210.62 | | | | | | 9)NOTE: NOTE#9 NO, PLEASE SEE PREVIOUS | | | NOTES MENTIONED MANY ITEMS WHERE LOADS, | | | EQUIPMENT PANELS ETC DID NOT CORRELATE | | | ON RISERS OR PANELS OR EQUIPMENT | | | SCHEDULE. | | | PLEASE SEE MANY OF THESE ITEMS WERE | | | REDLINED ON PLANS WHICH CAME THROUGH FOR | | | REVIEW AND NOT EACH AND EVERY ITEM WAS | | | TYPED INTO NOTES. | | | PLEASE SEE MANY ITEMS HAVE BEEN | | | CORRECTED , HOWEVER PLEASE SEE THERE ARE | | | A SOME WHICH STILL NEED TO BE ADDRESSED. | | | 1) PLEASE SEE CU-15 ON EQUIPMENT | | | SCHEDULE, HOWEVER CU-20 ON PANEL LD? | | | PLEASE SEE LOAD SHOWN ON LD DOES NOT | | | CORRELATE WITH EQUIPMNET SCHEDULE OR | | | RISER DIAGRAM. 81A;S SHOWN ON TWO AND | | | 64A'S SHOWN ON LD. | | | 2) PLEASE SEE LOAD SHOWN ON LD FOR PANEL | | | "A". THIS DOES NOT CORRELATE WITH LOAD | | | ON PANEL "A". | | | 3)PLEASE SEE LOAD CALCULATIONS DO NOT | | | CORRELATE WITH LOAD SHOWN ON PANEL "LD". | | | 4)PLEASE SEE AIC RATING OF PANEL "C" IS | | | SHOWN AS 10K, HOWEVER RISER SHOWS 31,532 | | | AVAILABLE. | | | | | | PLEASE SEE THE ABOVE COMMENTS. | | | | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER | | | REVIEWER(S) WHICH MAY HAVE AN AFFECT ON | | | ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-03-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-03 |
Time |
06:37 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2005-03-03 |
Time |
05:53 |
Sent To |
|
|
| Notes |
| 2005-03-03 00:00:00 | ********* UNSAT 2ND REVIEW ************ | | | | | | | | | ******** SWEET TOMATOES REST ********* | | | PLAN REVIEW ONLY, NOT SUBMITTED FOR | | | PERMIT AT THIS TIME. | | | | | | PLEASE SEE THERE ARE MANY ITEMS FROM | | | PREVIOUS REVIEW WHICH STILL NEED TO BE | | | ADDRESSED. | | | | | | | | | 1)NOTE: NOTE #1 NO, IF PLANS WERE READY | | | FOR PERMITTING, THIS WOULD NOT BE ABLE | | | TO BE STAMPED AND PROCESSED DUE TO PLANS | | | NOT BEING SIGNED, DATED AND SEALED BY | | | ARCHITECT/ ENGINEER(S). | | | PLEASE SEE FS 481.221,471.025 | | | PLANS ARE REQUIRED TO HAVE RAISED SEAL, | | | SIGNATURE AND DATED. | | | **PLEASE SEE ARCH SHEET CONTAINS A | | | "RUBBER STAMP" FOR SEAL. | | | | | | 2)NOTE: NOTE #2 NO, | | | PLEASE SEE PREVIOUS NOTES: PLEASE SEE | | | FAC 61G15-23.002, 61G1-16.004 FOR ALL | | | INFORMATION REQUIRED ON TITLE BLOCKS FOR | | | " ALL"SHEETS. REQUIRED UNDER FS | | | 471.023,481.219. | | | PLEASE SEE MISSING LICENSE INFORMATION | | | ON "S" SHEETS , "A" SHEETS AND ALL | | | "P","M", AND "E" SHEETS. | | | THE ABOVE COMMENT IS FOR ALL SHEETS AND | | | FOR ALL TRADES WHEATHER OR NOT COMMENT | | | IS MADE BY OTHER REVIEWERS. | | | | | | 3)NOTE: NOTE #3 OK. | | | | | | 4)NOTE: NOTE #4 OK. | | | | | | 5)NOTE: NOTE #5 MOST, PLEASE SEE CIRCUIT | | | B-16. | | | | | | 6)NOTE: NOTE #6 OK. | | | | | | 7)NOTE: NOTE #7 MOST, PLEASE SEE LARGEST | | | MOTOR LOADS (RTU) IS REQUIRED TO BE | | | SHOWN AT 125%. | | | | | | 8)NOTE: NOTE #8 NO, PLEASE SEE "ABOVE | | | WINDOW RECEPTS" COULD NOT BE LOCATED. | | | 210.62 THIS IS TO ALLEVIATE UNSIGHTLY | | | EXTENSION CORDS LIKELY TO CAUSE PHYSICAL | | | INJURY. MANY TIMES SIGNAGE SUCH AS ONES | | | FROM "VENDORS" ETC ARE INSTALLED IN | | | WINDOW AREAS ETC. THE RECEPTACLES MUST | | | BE INSTALLED DIRECTLY ABOVE A SHOW | | | WINDOW, AND ONE RECEPTACLE IS REQUIRED | | | FOR EVERY 12 LINEAR FT OR ?MAJOR | | | FRACTION THEREOF? (6 FT OR MORE). SEE | | | 220.3(B)(7) AND 220.12(A) FOR | | | INFORMATION REGARDING LOAD COMPUTATIONS | | | FOR SHOW WINDOWS. | | | | | | 9)NOTE: NOTE #9 NO, | | | PLEASE SEE OCPFOR RTUS',125% ETC, | | | PLEASE CORRELATE "LD" OCP WITH RISER AND | | | EQUIPMENT SCHEDULE. | | | PLEASE ALSO CORRELATE PANELS/ OCP AND | | | RISER. | | | PLEASE SEE "LD" IS SHOWN AS 1000A'S AND | | | RISER SHOWS 1200A'S? | | | PLEASE SEENOTE #15. | | | PLEASE SEE SALAD BAR ON RISER SHOWS 150A | | | BRKR ON #10 AWG. | | | PLEASE SEE PANEL "C", 400A'S WITH A 200A | | | BRKR AS FEED?? | | | ETC. | | | | | | 10)NOTE: NOTE #10 OK, HOWEVER SEE | | | PREVIOUS NOTE. | | | | | | 11)NOTE: NOTE #11 NO, PLEASE SEE 424.3B | | | AND PLEASE SEE NOTE #9. | | | | | | 12)NOTE: NOTE #12 OK. | | | | | | 13)NOTE: NOTE #13 NO, PLEASE SEE THERE | | | IS EQUIPMENT SHOWN ON "EQUIPMENT | | | SCHEDULE" BUT NOT LOCATED ON ANY PANEL | | | SCHEDULE. PLEASE SEE EQUIPMENT ON PANEL | | | SCHEDULES, BUT NOT ON EQUIPMENT | | | SCHEDULE? | | | WATER HEATER #2? | | | | | | 14)NOTE: NOTE #14 OK, HOWEVER, NOW AN | | | EQUIPMENT GROUNDING CONDUCTOR IS NOW | | | SHOWN WITH SEC'S. PLEASE SEE | | | 250.6,250.24, EQUIIPMENT GROUNDING | | | CONDUCTORS ARE ONLY INSTALLED AFTER THE | | | FIRST MEANS OF DISCONNECT. | | | THIS WAS NOT IN FIRST REVIEW AS SEC'S | | | WERE NOT SHOWN. | | | | | | 15)NOTE: NOTE #15 OK. | | | | | | 16)NOTE: NOTE #16 SEC'S ADDED, HOWEVER | | | PLEASE SEE MIN SIZE REQUIRED PER 240.3, | | | AND 310.16. | | | PLEASE SEE DEVICES WHICH ARE RATED OVER | | | 800A'S THE AMPACITY OF THE CONDUCTORS IT | | | PROTECTS SHALL BE EQUAL TO OR GREATER | | | THAN THE RATING OF THE OVERCURRENT | | | DEVICE DEFINED IN 240.6. | | | PLEASE SEE NOTE #9. | | | | | | **************************************** | | | | | | PLEASE SEE NOTE #2 ON THIS AND PREVIOUS | | | REVIEW. | | | *************************************** | | | | | | PLEASE SEE ONE SETOF PLANS HAVE BEEN | | | REDLINED FOR ITMES AS NOTED IN REVIEW. | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-14 |
Time |
14:24 |
Rev Time |
2.50 |
| Received By |
dpalmer |
Date |
2004-12-14 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2004-12-14 00:00:00 | NOTES TO FOLLOW. | | | ************** UNSAT****************** | | | SWEET TOMATOES | | | ********** PLAN REVIEW ONLY************ | | | *******NOT SUBMITTED FOR | | | PERMIT.******** | | | | | | 1)NOTE: PLEASE HAVE PLANS SIGNED, DATED | | | AND SEALED BY THE ARCH'S AND ENGINEERS | | | OF RECORD WHEN SUBMITTING FOR PERMIT. | | | PER FS 481.221,471.025 | | | | | | 2)NOTE: PLEASE SEE MISSING INFORMATION | | | REQUIRED ON TITLE BLOCKS FOR ARCHITECT | | | AND ENGINEERING FIRMS. | | | FAC 61G15-23.002, FAC 61G1-16.004 | | | FS 481.219,471.023. | | | THIS IS REQUIRED ON ALL SHEETS AND FOR | | | ALL TRADES WHEATHER OR NOT COMMENT IS | | | MADE BY OTHER REVIEWER(S). | | | | | | 3)NOTE: PLEASE SEE 600.5 EACH | | | COMMERCIAL | | | BUILDING AND EACH COMMERCIAL OCCUPANCY | | | ACCESSIBLE TO PEDESTRIANS SHALL BE | | | PROVIDED WITH AT LEAST ONE OUTLET IN AN | | | ACCESSIBLE LOCATION AT EACH ENTRANCE TO | | | EACH TENANT SPACE FOR SIGN OR OUTLINE | | | LIGHTING SYSTEM USE. THE OUTLET(S) | | | SHALL | | | BE SUPPLIED BY A BRANCH CIRCUIT RATED | | | AT | | | LEAST 20 AMPERES THAT SUPPLIES NO OTHER | | | LOAD. SERVICE HALLWAYS OR CORRIDORS | | | SHALL NOT BE CONSIDERED ACCESSIBLE TO | | | PEDESTRIANS. THIS CIRCUIT COULD NOT BE | | | LOCATED ON PANEL SCHEDULE. | | | | | | 4)NOTE: PLEASE PROVIDE ROOM/AREA | | | DESIGNATION ON PLANS. | | | | | | 5)NOTE: PLEASE SEE SECTION 210.8(B)(3) | | | IN THE 2002 CODE WHICH REQUIRES ALL 15- | | | AND 20-AMPERE, 125-VOLT RECEPTACLES IN | | | NONDWELLING-TYPE KITCHENS TO BE GFCI | | | PROTECTED. THIS REQUIREMENT APPLIES TO | | | EACH AND EVERY 15- AND 20-AMPERE, | | | 125-VOLT KITCHEN RECEPTACLE, WHETHER OR | | | NOT THE RECEPTACLE SERVES COUNTERTOP | | | APPLIANCES. | | | | | | 6)NOTE: PLEASE SEE 220.12 FOR TRK | | | LIGHTING CALCULATIONSTO BE SHOWN. | | | | | | 7)NOTE: PLEASE SHOW LOAD CALCULATIONS, | | | PLEASE SHOW PER | | | 220.3,220.10,220.11,220.13 ETC. | | | PLEASE ALSO SHOW ALL CONTINOUS LOADS | | | AT 125% PER 215.3,230.42 | | | | | | 8)NOTE: PLEASE SEE 210.62 FOR REQUIRED | | | MISSING RECEPTS.AT LEAST ONE RECEPTACLE | | | OUTLET SHALL BE INSTALLED DIRECTLY | | | ABOVE | | | A SHOW WINDOW FOR EACH 3.7 LINEAR M (12 | | | FT) OR MAJOR FRACTION THEREOF OF SHOW | | | WINDOW AREA MEASURED HORIZONTALLY AT | | | ITS | | | MAXIMUM WIDTH. | | | | | | 9)NOTE: PLEASE CORRELATE RISER "LD" | | | WITH | | | EQUIPMENT SHOWN ON E0.1. PLEASE SEE | | | OCP, | | | AWG ETC. | | | | | | 10)NOTE: PLEASE SEE PROVIDE A "PANEL | | | SCHEDULE" FOR LD SHOWING OVERCURRENT | | | PROTECTION, CONDUCOTR SIZES, CONDUIT | | | ETC. | | | PLEASE SEE THERE ARE MANY ITEMS ON LD | | | WHICH CONDUCTOR SIZES ETC COULD NOT BE | | | LOCATED. | | | 215.5 | | | | | | 11)NOTE: PLEASE IDENTIFY KW OF HEAT ON | | | A/C, RTU'S. | | | PLEASE SEE 424.3B FOR OCP.THE AMPACITY | | | OF THE BRANCH-CIRCUIT CONDUCTORS AND | | | THE | | | RATING OR SETTING OF OVERCURRENT | | | PROTECTIVE DEVICES SUPPLYING FIXED | | | ELECTRIC SPACE-HEATING EQUIPMENT | | | CONSISTING OF RESISTANCE ELEMENTS WITH | | | OR WITHOUT A MOTOR SHALL NOT BE LESS | | | THAN 125 PERCENT OF THE TOTAL LOAD OF | | | THE MOTORS AND THE HEATERS. | | | | | | 12)NOTE: PLEASE SEE PANEL SCHEDULES, | | | SOME ARE SHOWN WHERE ARE CIRCUITS ARE | | | INDICATED AS 1-POLE BRKRS? PLEASE SEE | | | SOME 2-P CIRCUITS. | | | | | | 13)NOTE: PLEASE SEE SOME EQUIPMENT ON | | | EQP SCH DOES NOT APPEAR ON PANEL | | | SCHEDULES OR RISER? | | | PLEASE CORRRELATE. | | | 215.5 | | | | | | 14)NOTE: PLEASE PROVIDE EQUIPMENT | | | GROUNDING CONDUCTORS FOR ALL AFTER THE | | | FIRST MEANS OF DISCONNECT. | | | 250.24,250.110,250.122 | | | | | | 15)NOTE: PLEASE SEE 250.66 FOR SIZING | | | OF | | | GROUNDING ELECTRODE CONDUCTOR. THIS IS | | | TO BE BASED ON SEC'S PER NEC. | | | | | | 16)NOTE: PLEASE VERIFY WITH FPL IF | | | SEC'S | | | (SERVICE ENTRANCE CONDUCTORS) WILL BE | | | BROUGHT INTO 1200A MAIN "LD" BY FPL? | | | PLEASE SEE RISER DIAGRAM DOES NOT | | | INDICATE AN METERING DEVICE, CT , ETC. | | | PLEASE SEE 2004 FPL SERVICE | | | SPECIFICATIONS AND REQUIREMENTS. | | | | | | ************ PLEASE NOTE ************* | | | DUE TO ABOVE COMMENTS AND MISSING | | | INFORMATION, A COMPLETE REVIEW FOR CODE | | | COMPLIANCE MAY NOT BE DONE AT THIS | | | TIME. | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWS WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | PLEASE SEE MANY OF THE ABOVE ITEMS HAVE | | | BEEN REDLINED ON PLANS FOR AREAS OF | | | CONCERN AND NOTES. | | | | | | PLEASE BE SURE TO REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO COMPLETE SETS FOR REVIEW | | | AND | | | STAMPING. | | | | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2006-07-25 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-07-25 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-07-25 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2006-07-25 00:00:00 | PASS WITH FOLLOWING CITY OF WPB | | | REQUIREMENTS: | | | 1. MUST MEET CITY OF WPB DUMPSTER & | | | RECYCLE PAD DETAIL.(ATTACHED FOR YOUR | | | INFO) | | | 2. MUST MEET CITY OF WPB SANITATION | | | REQUIREMENTS (ATTACHED FOR YOUR INFO) | | | | | | RASIK CHOKSHI 805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2005-02-24 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-02-24 |
Time |
10:20 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2005-02-24 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2004-12-02 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-12-02 |
Time |
15:24 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-12-02 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2004-12-02 00:00:00 | FAILED | | | | | | 1. SHEET CE-7, CONTROL STRUCTURE | | | DETAILS, PLEASE SHOW THE EXISTING 12" | | | PIPE TO THE OUTFALL AND ALSO THE 30^ | | | V-NOTCH ELEVATION MUST BE SHOWN. | | | | | | 2. SUNSHINE STATE ONE CALL BEFORE | | | DIGGING SHOULD BE ON ALL CIVIL SHEET, | | | 1-800-432-4770. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-07-12 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-07-12 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-06-01 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-06-01 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2005-06-01 00:00:00 | ****PROVISO**** | | | | | | 1) PLEASE SEE OTHER REVIEW COMMENTS IN | | | REGARDS TO FS AND FAC REQUIREMENTS. | | | | | | 2) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE SUPPRESSION AND | | | HOOD SYSTEMS. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 835-2951 OR 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2005-03-24 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-03-24 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-03-24 |
Time |
11:31 |
Sent To |
M |
|
| Notes |
| 2005-03-24 00:00:00 | THANK YOU FOR THE EXPLANATIONS REGARDING | | | THE FIRST REVIEW, HOWEVER THE FOLLOWING | | | WILL REQUIRE ADDITIONAL CLARRIFICATION. | | | | | | 1) PLEASE PROVIDE FURTHER DETAILS | | | REGARDING HOW PERSONS WILL BE DIRECTED | | | TO AN EXIT IN THE KITCHEN IF POWER | | | FAILURE OCCURS. | | | | | | 2) PLEASE PROVIDE PRODUCT APPROVAL CUT | | | SHEETS FOR THE GREASE DUCT WRAP. | | | | | | 3) PLEASE EXPLAIN HOW THE LOCAL | | | AMMENDMENTS TO THE FLORIDA BUILDING CODE | | | | | | WILL BE MET IN REGARDS TO THE BUILDING | | | BEING LOCATED WITHIN THE CITY FIRE | | | LIMITS. | | | | | | | | | MIKE WENNERGREN, ACTING CAPTAIN | | | WPBFR(561) 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-12-27 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-12-27 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-12-27 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2004-12-27 00:00:00 | 1. ALL DEMOLITION, RENOVATION AND | | | CONSTRUCTION TO COMPLY WITH | | | NFPA 241. | | | | | | 2. WHAT PROVISIONS MADE FOR FIRE | | | AND PARAMEDICAL ACCESS THRU THE | | | SLIDING GATE. | | | | | | 3. FLORIDA FIRE PREVENTION CODE | | | NOT MENTIONED IN CODE COMPLIANCE | | | BOX. | | | | | | 4. GENERAL NOTES AND CODE COMPLIANCE | | | BOX WITH REGARDS TO FIRE SPRINKLERS | | | DO NOT MATCH. | | | | | | 5. SEPARATE PLANS AND PERMITS REQUIRED | | | FOR ANY HOOD, DUCT, AND FIRE | | | SUPPRESSION SYSTEMS. | | | | | | 6. HOW ARE PERSONS DIRECTED TO EXIT | | | DOOR IN ENTRY AREA 100. | | | | | | 7. NO EMERGENCY LIGHTING COULD BE | | | LOCATED IN THE KITCHEN. WHAT DIRECTS | | | PERSONS TO THE EXITS SHOULD POWER | | | FAIL. | | | | | | 8. PLEASE PROVIDE PRODUCT APPROVALS FOR | | | GREASE DUCT WRAP. | | | | | | 9. PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATIONS FOR WALLS AND CEILINGS. | | | | | | 10. EXIT SIGN MISSING FROM REFLECTED | | | CEILING PLAN ENTRY 100. | | | | | | 11. PANIC HARDWARE REQUIRED ON ALL | | | EXIT DOORS. | | | | | | 12. BUILDING MAY BE LOCATED IN CITY | | | FIRE LIMITS. CERTAIN RESTICTIONS | | | MAY APPLY, SEE APPENDIX F, LOCAL | | | AMENDMENTS TO THE FLORIDA BUILDING | | | CODE. | | | | | | 13. BUILDING ADDRESS REQUIRED. A | | | MINIMUM OF 6" HIGH NUMBERS ARE | | | REQUIRED. | | | | | | 14. PLEASE CLEARLY ILLUSTRATE PORTABLE | | | FIRE EXTINGUISHER LOCATIONS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2006-08-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-16 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-16 |
Time |
17:34 |
Sent To |
M |
|
| Notes |
| 2006-08-16 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2006-08-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-12 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-12 |
Time |
13:26 |
Sent To |
E |
|
| Notes |
| 2006-08-12 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2006-08-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-12 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-12 |
Time |
13:15 |
Sent To |
G |
|
| Notes |
| 2006-08-12 00:00:00 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2006-08-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-12 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-12 |
Time |
13:05 |
Sent To |
B |
|
| Notes |
| 2006-08-12 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2006-07-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-13 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-13 |
Time |
15:53 |
Sent To |
M |
|
| Notes |
| 2006-07-13 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-28 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-28 |
Time |
14:54 |
Sent To |
M |
|
| Notes |
| 2006-06-28 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-06-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-26 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-26 |
Time |
14:33 |
Sent To |
B |
|
| Notes |
| 2006-06-26 00:00:00 | TO "JWITMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-21 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-21 |
Time |
13:12 |
Sent To |
B |
|
| Notes |
| 2006-06-21 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-19 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-19 |
Time |
09:57 |
Sent To |
M |
|
| Notes |
| 2006-06-19 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-19 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-19 |
Time |
09:53 |
Sent To |
Z |
|
| Notes |
| 2006-06-19 00:00:00 | TO "Z" BOX/REV--DUMPSTER ENCLOSURE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-19 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-19 |
Time |
09:52 |
Sent To |
B |
|
| Notes |
| 2006-06-19 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-22 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-22 |
Time |
09:39 |
Sent To |
B |
|
| Notes |
| 2005-10-22 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-06-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-29 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-29 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2005-06-30 00:00:00 | TO "COMM" BD#53 | | 2005-06-29 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-05-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-04 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-04 |
Time |
14:55 |
Sent To |
I |
|
| Notes |
| 2005-05-04 00:00:00 | TO "COMM" BD#53 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-04-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-29 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2005-05-03 00:00:00 | IN INCOMING/AWAITING SPACE ON "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-23 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-23 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2005-02-23 00:00:00 | TO "COMM" BD#45 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-03-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-06 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2004-11-30 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2004-11-30 00:00:00 | SENT TO COMM BD#39 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-08-03 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-08-03 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2006-06-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-29 |
Time |
10:26 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-06-29 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2006-06-29 00:00:00 | REVISION TO MECH. PLANS PAGE M1.1 & M2.1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-21 |
Time |
10:45 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-06-21 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2006-06-21 00:00:00 | MECHANICAL REVISION TO HOOD | | | *** DENIED *** | | | 1) MECHANICAL PLANS PAGE M2.1 ARE SEALED | | | ENGINEERED PLANS ONLY THE ENGINEER | | | (THOMAS H. MAXWELL) CAN MAKE CHANGES TO | | | THE PLANS. | | | | | | 2) PLEASE SEE PAGE M2.1 TITLE BLOCK | | | (REVISIONS) TWO REVISIONS MADE ON | | | DIFFERENT DATES ARE EACH IDENTIFIED AS | | | #1, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-13 |
Time |
06:39 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-07-13 |
Time |
06:34 |
Sent To |
|
|
| Notes |
| 2005-07-13 00:00:00 | PLANS SUBMITTED AS "PLAN CHECK", PLEASE | | | SUBMIT FOR PERMIT. | | | | | | ADDITIONAL PERMITS REQUIRED FOR HOOD, | | | FIRE SUPPRESSION, AND WALK-IN COOLERS. | | | PLANS SUBMITTED WITH BUILDING PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-06-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-06-01 |
Time |
08:54 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-06-01 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2005-06-01 00:00:00 | PROVISO:PLAN CHECK ONLY | | | 1.ADDITIONAL PERMITS REQUIRED FOR THE | | | HOOD, FIRE SUPPRESSION, AND WALK-IN | | | COOLERS. | | | | | | 2.PROVIDE MANUFACTURER'S CUT SHEETS | | | FOR THE WAL-IN COOLER. | | | | | | 3.PROVIDE DETAIL OF GREASE DUCT | | | LAYOUT.SHOW CLEARANCES TO | | | COMBUSTIBLES. | | | | | | 4.PROVIDE FPM IN THE GREASE DUCT. | | | SHOW COMPLAINCE WITH NFPA 96 & 2001 | | | FBC(M) CHAPTER 5. | | | | | | PLANS ARE OTHERWISE CODE COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-31 |
Time |
06:52 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-03-31 |
Time |
06:52 |
Sent To |
|
|
| Notes |
| 2005-03-31 00:00:00 | DENIED:PLAN CHECK ONLY | | | 1.2ND REQUEST - PROVIDE ENERGY AND | | | MANUAL J CALCULATIONS IN ACCORDANCE WITH | | | 2001 FBC CHAPTER 13 SUB-CHAPTER 4. | | | | | | 2.2ND REQUEST - PROVIDE OUTSIDE AIR | | | CALCULATIONS PER 2001 FBC/M TABLE 403.3. | | | | | | 3.2ND REQUEST - PROVIDE RETURN AIR | | | FROM THE OFFICE AREA. SHOW COMPLIANCE | | | WITH 2001 FBC/M 601.4. | | | | | | 4.2ND REVIEW ADDTIONAL COMMENT FOR THE | | | CONDENSATE.CONDENSATE TO TERMINATE | | | INTO THE STORM SEWER AND NOT THE | | | SANITARY PER CITY COD SEC. 90-125 (5). | | | | | | 5.2ND REQUEST - HOOD & FIRE | | | SUPPRESSION PLANS ARE PROVIDED BY THE | | | ENGINEER (PLAN SHEET M2.1) AND ALSO BY | | | CAPTIVEAIRE (PLAN SHEET K7.0).PLEASE | | | CLARIFY IF THE MECHANICAL ENGINEER WILL | | | BE DESIGNING THE HOOD SYSTEM OR | | | CAPTIVEAIRE.PLEASE NOTE, SHOULD | | | CAPTIVEAIRE PLAN BE USED, PLANS SHALL BE | | | SIGNED & DATED BY THE DESIGNER. | | | | | | 6.NEW COMMENT - PLAN SHEET M2.1 DETAIL | | | #2 CONDENSATE UNIT CURB.DETAIL DOES | | | NOT INDICATE ANCHORING OR TIE DOWN FOR | | | THE CONDENSING UNIT TO THE CURB.PLEASE | | | NOTE, CURBS ARE TO BE A MINIMUM OF 8" | | | ABOVE THE ROOF SURFACE PER 2001 FBC | | | 1511.7. | | | | | | SEE COMMENT #2 BY DEWEY PALMER, | | | ELECTRICAL PLAN REVIEW. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-03 |
Time |
06:45 |
Rev Time |
3.00 |
| Received By |
pkrauss |
Date |
2004-12-31 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2005-01-03 00:00:00 | DENIED: | | | 1.PROVIDE ENERGY AND MANUAL J | | | CALCULATIONS AS REQUIRED PER 2001 FBC | | | CHAPTER 13 SUB-CHAPTER 4. | | | | | | 2.PROVIDE MANUFACTURER SUBMITTAL & | | | INSTALLATION INSTRUCTIONS FOR THE | | | KITCHEN EQUIPMENT AND THE FIREPLACE. | | | | | | 3.ADDITIONAL PERMITS REQUIRED FOR THE | | | HOOD, FIRE SUPPRESSION, WALK-IN | | | COOLERS, | | | AND GAS. | | | | | | 4.PROVIDE OUTSIDE AIR CALCULATIONS IN | | | ACCORDANCE WITH 2001 FBC(M) TABLE | | | 403.3. | | | | | | 5.RETURN AIR REQUIRED FROM ROOMS | | | SEPARATED FROM THE CENTRALLY LOCATED | | | RETURN AIR I.E., OFFICE AREA, LOCKER | | | ROOM.2001 FBC(M)601.4. | | | | | | 6.PROVIDE CONDENSATE LAYOUT & | | | TERMINATION. | | | | | | 7.FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | | WITH NOTIFICATION TO A/ARM/STROBE | | | REQUIRED PER 2001 FBC(M)606.2.1 & | | | 606.4.1 #2. | | | | | | HOOD/FIRE SUPPRESSION: | | | PLEASE NOTE, PLANS SUBMITTED BY CAPTIVE | | | AIR (K-7 & K-8) DO NOT HAVE ENOUGH | | | DETAIL FOR A COMPLETE REVIEW. | | | HOOD/SUPPRESSION PLANS ARE ALSO | | | SUBMITTED BY THE MECHANICAL ENGINEER | | | WHICH ARE MORE SPECIFIC.PLEASE | | | PROVIDE | | | THE FOLLOWING INFORMATION: | | | 1) PLAN SHEET M2.1 DETAIL #13, PROVIDE | | | DETAIL FOR SPECFIC INSTALLATION AS | | | SHOWN | | | ON DETAIL #22. | | | 2) AIR VELOCITY WITHIN THE GREASE DUCT | | | SYSTEM SHALL BE NOT LESS THAN 1,500 FPM | | | & NOT GREATER THAN 2,500 FPM. | | | 3) FIRE MASTER DUCT WRAP INDICATED ON | | | DETAIL 8, MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS SHALL BE ON THE JOBSITE AT | | | THE TIME OF INSPECTION. | | | 4) PLAN REVIEW FOR THE HOOD & FIRE | | | SUPPRESSION CAN BE APPROVED WITH THE | | | BUILDING REVIEW OR PLANS MAY BE | | | SUBMITTED AND REVIEWED AT THE TIME OF | | | SUBMITTAL FOR THE HOOD/SUPPRESSION | | | PERMITS.PLEASE DO NOT SUBMIT PLANS BY | | | TWO DIFFERENT ENGINEERS. | | | | | | PLANS, SPECIFICATIONS AND REPORTS ARE TO | | | BE SIGNED, SEALED AND DATED BY THE | | | ARCHITECT/ENGINEER RESPONSIBLE FOR THE | | | DESIGN PER FS 481.221, 471.025.PLANS | | | SHALL ALSO COMPLY WITH 61G5-23.0002 & | | | 61G1-16.004. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2006-09-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-09-12 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-09-12 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2006-09-12 00:00:00 | REVISED GAS EQUIPMENT BTU'S |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-07-06 |
Time |
16:22 |
Rev Time |
1.50 |
| Received By |
jleech |
Date |
2005-07-06 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2005-06-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-06-03 |
Time |
08:14 |
Rev Time |
4.50 |
| Received By |
jleech |
Date |
2005-06-03 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2005-06-03 00:00:00 | DENIED; | | | 1.NOTE 1 NOT ADDRESSED,WATER AND SEWER | | | PLAN CE-5 GREASE INTERCEPTOR CANNOT BE | | | 1600 GAL. SEE FBC PLUMBING SECTION | | | 1003.5(1200 GAL.MAX. THIRD | | | NOTICE.PLEASE USE FBC PLUMBING TABLE | | | 1003.5.1 TO CALKULATE SIZE OF GREASE | | | TRAP. | | | 2.NOTE 3 NOT ADDRESSED, PLEASE CONTACT | | | RODNEY COMPO ENVIROMENT COMPLIANCE, | | | FORAPPROVAL FOR GREASE TRAP. YOU CAN | | | REACH RODNEY AT; [email protected], OR FAX | | | (561)659-7458, | | | OR CALL AT (561)659-4074. | | | 3.A/C CONDENSATE DRAINAGE MUST COMPLY TO | | | FBC MECHANICAL SEC.307.2.1. (MUST GO TO | | | STORM CATCH BASIN OR TO A DRYWELL.) | | | 4.2-WAY C.O. REQUIRED ON OUTLET SIDE OF | | | GREASE TRAP. | | | 5.DWV ISOMETRIC,H/C LAVS. REQUIRE VENTS. | | | 6.SHOW TYPE OF PIPING MATERIAL BING | | | INSTALLED AND METHOD. | | | 7.SHOW MANUFACTOR AND MODEL NUMBER OF | | | REGULATORS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-03-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-03-12 |
Time |
13:00 |
Rev Time |
5.00 |
| Received By |
jleech |
Date |
2005-03-12 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2005-03-12 00:00:00 | 1.WATER AND SEWER PLAN CE-5 GREASE | | | INTERCEPTOR CANNOT BE 1600 GAL SEE FBC | | | PLUMBING SEC. 1003.51250 GAL MAX. SECOND | | | NOTICE. | | | 2.PLANS MUST BE REVIEW BY DEPTMENT OF | | | HOTEL AND RESTURANTS BEFORE PLAN REVIEW | | | BY WPB. SECOND NOTICE. | | | 3.NO APPROVAL HAS BEEN RECIEVED FROM | | | UTILITY DEPARTMENT FOR GREASE INTERCETOR | | | 2ND NOTICE. | | | 4.SECONDARY ROOF DRAINS ARE NOT TO CODE | | | SEE SEC. 1106. | | | 5.RAINWATER LEADERS MUST TIE INTO CATCH | | | BASINS NOT TO PLASH BLOCKS. MUST RETAIN | | | FIRST INCH. OF RAIN ON PROPERTY. | | | 6.VENT FROM GREASE INTERCEPTOR NOT | | | REQUIRED AND IS A CODE VIOLATION NO | | | HORIZONTAL DRY VENTS. | | | 7.CONDENSATE FROM A/C UNITS ON ROOF GO | | | TO STORM SEWER NOT SANITARY SEWER. | | | UTILITY DEPARTMENT ORD. | | | 8GW FIRST TWO FIXTURES ARE NOT VENTED, | | | FLOOR SINK AND FLOOR DRAIN. | | | 9.INDIRECT WASTES TO GO TO FLOOR SINKS | | | NOT FLOOR DRAINS. | | | 10.PLEASE SUBMIT MANUFACTORS SPECS. FOR | | | REGULATORS. | | | 11.SHUTOFF VALVES TO BE INSTALLED BEFORE | | | REGULATORS WITH UNION AFTER REGULATOR | | | FOR REPLACEMENT IF NEEDED. | | | 12.INSTALL A UNION AT EMERGENCY SHUTOFF | | | VALVE FOR REPLACEMENT IF NEEDED. | | | 13.PLEASE LIST COOKING EQUIPMENT BTU'S | | | ON SAME PAGE AS RISER DIAGRAM AND TOTAL | | | BTU'S SO I CAN CHECK PIPE SIZING. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-06 |
Time |
07:11 |
Rev Time |
3.50 |
| Received By |
jleech |
Date |
2005-01-06 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2005-01-06 00:00:00 | DENIED; | | | PLANS MUST BE REVIEW BY THE DEPARTMENT | | | OF HOTEL AND RESTAURANTS BEFORE PLAN | | | REVIEW BY THE CITY OF WEST PALM BEACH. | | | GREASE TRAP; PAGE CE-5, FBC PLUMBING SEC | | | 1003.5 THE LARGEST TANK PERMITED IS 1250 | | | GAL. GREASE TANKS CAN BE INSTALLED IN | | | SERIES. SITE PLANS CALL FOR 1600 GAL | | | CALCULATIONS ON PLUMBING PAGES INDICATE | | | A 2000 GAL. REQUIRED. ALSO GREASE TRAPS | | | MUST BE APPROVED BY THE UTILITY | | | DEPARTMENT.CONTACT RODNEY COMPO AT | | | 561-837-4074. | | | RISER DIAGRAMS REQUIRED FOR WARER, | | | SANITARY, GREASY WASTE, RAINWATER. | | | SIZE RAIN WATER PIPING USING CHAPTER 11 | | | OF THE FBC PLUMBING | | | PLEASE SIZE EMERGENCY OVERFLOW | | | SCUPPERS. | | | GAS; | | | ISOMETRIC TO CLEARLY SHOW ALL CUT | | | SECTIONS OF PIPE AND CORRESPONDING | | | LEAGHS PER FBC FUEL GAS. | | | CUT SHEETS REQURED FOR REGULATORS. | | | SHUTOFF VALVES REQUIRED UP STREAM OF | | | REGULATORS AND EMERGENCY HOOD SHUTOFF | | | FOR REPAIR PURPOSES. | | | GAS RISER DIAGRAM PAGE P2.3. PIPE FROM | | | METER TO FIRST TEE NOT SIZED. PIPE FROM | | | WARER HEATER TEE TO ROOF RISER TEE NOT | | | SIZED. PLEASE USE FBC FUEL GAS TO SIZE | | | ALL GAS PIPE TABLES ARE IN CHAPTER 4. | | | PLUMBING PLANREVIEW BY | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-20 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-06-20 |
Time |
16:40 |
Sent To |
I |
|
| Notes |
| 2006-06-20 00:00:00 | DUMPSTER WILL BE LOCATED IN THE SAME | | | LOCATION AS APPROVED IN PPRC (SITEPLAN | | | REVIEW) |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-06-25 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-06-25 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2005-07-08 00:00:00 | APPROVED BY GRACE JOYCE, PLANNER | | | 822-1435 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-02-24 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-02-24 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-02-24 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2005-02-24 00:00:00 | DENIED, | | | 1. APPLICANT WILL RESUB A REVISION TO | | | FRONT ELEVATION. | | | | | | GRACE JOYCE | | | PLANNER | | | PLANNING & ZONING | | | 822-1447 |
|
|