| Plan Review Stops For Permit 04111230 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-14 |
Time |
11:58 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-12-14 |
Time |
11:58 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-12-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-09 |
Time |
11:04 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-12-09 |
Time |
11:02 |
Sent To |
PC |
|
| Notes |
| 2004-12-09 00:00:00 | ***CORRECTIONS*** | | | | | | 1.)REVISE VALUE TO INCLUDE NEW | | | SHEATHING | | | | | | 2.)APPLY FOR SEPARATE PERMITS FOR ALL | | | BUILDINGS | | | | | | 3.)SEE ATTACHED AMENDMENTS TO THE | | | FBC2307.6B.HAVE ENGINEER PROVIDE A | | | SPECIFICATION FOR REPAIR THAT IS CODE | | | COMPLIANT.REPAIRS PROPOSED BY | | | CONTRACTOR, 7/16 OSB OR 15/32 CDX DO NOT | | | MEET MINIMUM ROOF SHEATHING CRITERIA. | | | TRUSS SPACING NOT ADDRESSED IN | | | ENGINEERING. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-12-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-07 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-12-07 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2004-12-07 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.) THE ENGINEER'S SPECIFICATION | | | (INSTALLATION OVER 1/4" PLYWOOD DECK) | | | CONFLICTS WITH THE PRODUCT APPROVAL, | | | DECK DESCRIPTION, RE-ROOF 15/32" | | | PLYWOOD | | | MINIMUM.PROVIDE DESIGN INFORMATION AS | | | TO HOW THIS SPECIFICATION IS CODE | | | COMPLIANT IN REGARDS TO WIND LOADS. | | | | | | 2.)CONVERSATIONS WITH THE CONTRACTOR | | | IN REGARDS TO INSTALLATION METHODS | | | CONFLICT WITH THE ENGINEER'S | | | SPECIFICATION.CODE ISSUES WITH | | | ALTERNATE INSTALLATIONS HAVE NOT BEEN | | | ADDRESSED. | | | | | | ***NO RESUB FEE*** | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-30 |
Time |
10:34 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-11-30 |
Time |
10:34 |
Sent To |
PC |
|
| Notes |
| 2004-11-30 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SCOPE OF WORK ALLOWED PER | | | GOVERNOR'S DECLARATION, DETERMINATION OF | | | BUILDING OFFICIAL AND PALM BEACH COUNTY | | | LICENSING (KURT EISMANN). | | | | | | 2.)PROVIDE ENGINEERING TO SHOW HOW | | | LATERAL SUPPORT FOR THE TRUSSES IS | | | BEING | | | ADDRESSED.FROM YOUR DESCRIPTION OF | | | WORK YOU ARE REMOVING STRUCTURAL SIDING | | | AND REPLACING IT WITH A NON STRUCTURAL | | | ROOF. | | | | | | 3.)NO RESUB FEE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-30 |
Time |
08:24 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-11-30 |
Time |
08:24 |
Sent To |
PC |
|
| Notes |
| 2004-11-30 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEE ATTACHED ROOFING/REROOF POLICY. | | | THE APPLICATION SHOULD INCLUDE ALL | | | REQUIRED INFORMATION. | | | | | | 2.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVAL REQUIRED IN ADDITION TO TEST | | | REPORT.PLEASE SEE ATTACHED POLICY. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-30 |
Time |
10:35 |
Rev Time |
|
| Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
N |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-30 |
Time |
10:35 |
Rev Time |
|
| Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-12-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-07 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-07 |
Time |
08:24 |
Sent To |
B |
|
| Notes |
| 2004-12-07 00:00:00 | SENT TO "SH" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-23 |
Time |
18:33 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-23 |
Time |
18:33 |
Sent To |
B |
|
| Notes |
| 2004-11-23 00:00:00 | SESNT TO "B" TO MISC BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-30 |
Time |
10:35 |
Rev Time |
|
| Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-30 |
Time |
10:36 |
Rev Time |
|
| Received By |
shill |
Date |
|
Time |
|
Sent To |
PC |
|
| Notes |
|
|