| Plan Review Stops For Permit 04111066 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-12-23 |
Time |
08:34 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2004-12-23 |
Time |
08:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-03 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-12-03 |
Time |
14:08 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2004-12-03 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2004-12-03 00:00:00 | BUILDING PLAN REVIEW FAILED: | | | | | | 1. VALUE OF POOL ADJUSTED PER FBC | | | 104.6.5 USING MARSHALL/SWIFT COST | | | GUIDE. | | | | | | 2. SEE ZONING NOTE ON DECK LOCATION | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-12-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-15 |
Time |
12:22 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-12-15 |
Time |
12:22 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-11-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-24 |
Time |
07:37 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-11-24 |
Time |
07:37 |
Sent To |
P |
|
| Notes |
| 2004-11-24 00:00:00 | | | | ********** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE WIRING DIAGRA, SHOWS | | | 30A FOR 1HP BLOWER AND 40A FOR 1 1/2 HO | | | PUMP?? | | | PLEASE SEE 430.151(TABLES) FOR LOADS OF | | | PUMPS. | | | MIN OCP AND MAX OCP 430.52 ETC. | | | PLEASE ALSO SEE 310.16 FOR AWG AND 240.4 | | | FOR PROTECTION OF CONDUCTORS. | | | | | | 3)NOTE: PLEASE SEE BLDG REVIEW FOR | | | VALUATION PER FBC 104.6.5. | | | VALUE IS TO INCLUDE ALL LABOR AND | | | MATERIALS EVEN IF OWNER SUPPLIED. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-14 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-14 |
Time |
08:16 |
Sent To |
E |
|
| Notes |
| 2004-12-14 00:00:00 | SENT TO "DP" DESK/RRESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-12-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-06 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-06 |
Time |
15:34 |
Sent To |
Z |
|
| Notes |
| 2004-12-06 00:00:00 | SENT TO "Z" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-23 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-23 |
Time |
17:10 |
Sent To |
E |
|
| Notes |
| 2004-11-23 00:00:00 | SENT TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-11-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-19 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-19 |
Time |
11:16 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-23 |
Time |
05:20 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-12-23 |
Time |
05:20 |
Sent To |
B1 |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-23 |
Time |
05:15 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-12-23 |
Time |
05:15 |
Sent To |
B1 |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-12-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-03 |
Time |
08:17 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-12-03 |
Time |
07:50 |
Sent To |
B1 |
|
| Notes |
| 2004-12-03 00:00:00 | DENIED | | | REFERENCE: FBC-2001 424.2 SWIMMING | | | POOLS | | | | | | | | | 1) FBC-2001 424.2.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | | SHEETS REQUIRED. (SUBMITTAL) | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-12-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-12-13 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-12-13 |
Time |
18:28 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-11-23 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-11-23 |
Time |
16:52 |
Sent To |
I |
|
| Notes |
| 2004-11-23 00:00:00 | DENIED: DECK OR SCREEN ENCLOSURE MUST BE | | | 3FT.CALLED CONTR MM |
|
|