| Plan Review Stops For Permit 04110993 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
F |
Date |
2005-08-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-14 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2006-02-03 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2005-09-14 00:00:00 | REVISIONS #8 6-10-05 A3.02, A3.04, S3.05 | | | & S3.06. | | | REVISION #10 7-07-05 S3.03 S3.04 &S5.02 |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-02 |
|
|
Cont ID |
|
| Sent By |
ptjomsto |
Date |
2005-02-02 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
ptjomsto |
Date |
2005-02-02 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2005-02-02 00:00:00 | SENT TO ADDRESSING AGAIN TO VERIFY WITH | | | JOHN EXTENSIONS WERE CREATED FOR THE | | | THREE LOTS/PROJECT CONSISTS OF THREE | | | WAREHOUSES BEING BUILT ON THIS PARCEL |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2004-12-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-12-17 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
jhiggins |
Date |
2004-12-17 |
Time |
16:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
P |
Date |
2006-03-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-03-02 |
Time |
11:29 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2006-03-02 |
Time |
11:29 |
Sent To |
PC |
|
| Notes |
| 2006-03-02 00:00:00 | REV # 18 OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
F |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-03 |
Time |
09:55 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2006-02-03 |
Time |
09:55 |
Sent To |
PC |
|
| Notes |
| 2006-02-03 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04110993 | | | ADD: 5405 N HAVERHILL BLDG# 1 | | | CONT:MILLER | | | TEL: (786)303-8374 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REV STRUC REVIEW | | | ACTION: DENIED | | | | | | REVISION# 13 10-05-05 | | | PLANS INDICATE CHANGES IN THE BASIC | | | DESIGN WINDLOAD: | | | | | | PLANS INDICATE WIND VELOCITY REQUIRED | | | 3-SECOND GUST @ 146 MPH EXPOSURE"C" | | | | | | THE BUILDING WAS NOT DESIGNED UNDER | | | THESE COEFICIENT FACTORS, THE PRODUCT | | | APPROVAL WILL NOT HAVE HIGH ENOUGH | | | PRESSURES FOR 146 MPH EXPOSURE "C". | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-03 |
Time |
09:49 |
Rev Time |
2.20 |
| Received By |
jwitmer |
Date |
2006-02-03 |
Time |
07:37 |
Sent To |
PC |
|
| Notes |
| 2006-02-03 00:00:00 | ARCH REV REVIEWEDJW | | | A1.01 REV# 12 12-01-05 | | | A3.01 REV# 13 10-05-05 | | | A3.05 REV# 13A 10-05-05 | | | A3.08 REV# 12A 12-05-05 | | | A6.01 REV# 12A 12-05-05 | | | A6.02 REV# 12A 12-05-05 | | | A6.03 REV# 12A 12-05-05 | | | A6.04 REV# 12A 12-05-05 | | | A8.01 REV# 12 12-05-05 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2005-12-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-12-23 |
Time |
16:04 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2005-12-23 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-09-14 |
Time |
09:08 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-09-14 |
Time |
09:07 |
Sent To |
PC |
|
| Notes |
| 2005-09-14 00:00:00 | REVISON# 8 DATED 6-10-05 A3.02, A3.04 | | | S3.05 & S3.06 | | | REVISION# 10 DATED 7-07-05 S3.03, | | | S3.04 & S5.02 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2005-08-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-14 |
Time |
16:11 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-14 |
Time |
16:11 |
Sent To |
P |
|
| Notes |
| 2005-08-14 00:00:00 | BLDG# 1 TIE IN SURVEY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-08-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-14 |
Time |
15:45 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-14 |
Time |
15:45 |
Sent To |
PC |
|
| Notes |
| 2005-08-14 00:00:00 | CONCRETE MIX DESIGN REPORTS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-26 |
Time |
07:34 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-07-26 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2005-07-26 00:00:00 | SOILS LETTER OF COMPLIANCEJW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-06-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-13 |
Time |
10:43 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-06-13 |
Time |
10:43 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-01 |
Time |
12:00 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2005-06-01 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2005-06-01 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04110993 | | | ADD:5405 N HAVERHILL RD PH# 1 | | | CONT:NORTON CONSTRUCTION | | | TEL:(561)252-0590 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1A) THE NOTES ABOVE MAY BE TAKEN AS | | | GENERAL COMMENTS, BUT REMOVE ALL VOIDED | | | PAGES SUBMIT ONLY (1) SET OF OLD VOID | | | SHEETS. | | | 1B) A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER WITH A | | | DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND . | | | | | | 2)COMMENT #5 FROM THE PREVIOUS REVIEW: | | | FBC* 105.3RESIDENT INSPECTOR. SUBMIT | | | INSPECTOR RESUME' AND LICENSE DOCUMENTS | | | TO HAROLD PISKURA, DIRECTOR OF THE | | | RESIDENT INSPECTOR PROGRAM.A RESIDENT | | | INSPECTOR PROGRAM IS REQUIRED, ON THIS | | | PROJECT, DUE TO ONE OR MORE OF THE | | | FOLLOWING: | | | - BUILDINGS/ADDITIONS OF TYPE I OR II | | | CONSTRUCTION | | | - ANY MAJOR STRUCTURAL ALTERATIONS | | | - STRUCTURES IN WHICH THE CONCRETE | | | DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F'C) IN EXCESS OF 3000 PSI | | | - PILE DRIVING | | | - BUILDINGS OVER 20,000 SQFT IN AREA | | | - BUILDINGS OVER 2 STORIES IN HEIGHT | | | - BUILDING/STRUCTURES OF UNUSUAL DESIGN | | | OR METHODS OF CONSTRUCTION | | | | | | 3) COMMENT #3 FROM THE PREVIOUS REVIEW: | | | 106.4.2 STORAGE & FACTORY- INDUS- TRIAL | | | OCCUPANCIES. IT SHALL BE THE | | | RESPONSIBILITY OF THE OWNER, AGENT, | | | PROPIETOR OR OCCUPANT OF GROUP S AND | | | GROUP F OCCUPANCIES, OR ANY OCCUPANCY | | | WHERE EXCESSIVE FLOOR LOADING IS LIKELY | | | TO OCCUR, TO EMPLOY A COMPETENT ARCHI- | | | TECT OR ENGINEER IN COMPUTING THE SAFE | | | FLOOR LOAD CAPACITY. ALL SUCH COMPUTA- | | | TIONS SHALL BE ACCOMPANIED BY AN AFFA- | | | DAVIT FROM THE ARCHITECT OR ENGINEER | | | STATING THE SAFE ALLOWABLE FLOOR LOADS | | | ON EACH FLOOR IN POUNDS PER SQ FT.THE | | | COMPUTATIONS & AFFADAVIT SHALL BE FILED | | | AS A PERMANENT RECORD OF THE BLDG DEPT. | | | | | | 4) COMMENT #4 FROM THE PREVIOUS REVIW: | | | PLEASE PROVIDE THE MINIMUM BLDG DESIGN, | | | THIS BLDG IS DESIGNED? | | | A0.01 UNDER ALLOWABLE HEIGHT AND | | | BUILDING AREA INDICATES 72,000 SQ FT | | | BUT THE BLDG TYPE: IS TYPE V UNPROTECTED | | | FULLY SPRINKLERED. THIS RATING IS GOOD | | | FOR ONLY 48,000 SQ FT.AGAIN HOW ARE YOU | | | COMPLYING WITH TABLE 500? THE TOTAL SQ | | | FT( INCLUDING MEZZANINE) IS 65,199 SQ | | | FT. IF AREA INCREASES WERE TAKEN PROVIDE | | | THE CALCULATION! DO NOT FORGET THE AREA | | | OF THE MEZZANINE TO BE INCLUDED FOR | | | TOTAL AREA OF BUILDING. SEE DEFINITION | | | OF AREA GROSS. | | | THE 8X11 SHEET FAXED INDICATED THE | | | ASSUMED PROPERTY LINE ON THE NORTH SIDE | | | OF THE BUILDING WHY IS IT NOT AS | | | DISCUSSED? | | | | | | 5A)COMMENT #6 FROM THE PREVIOUS REVIEW: | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT | | | APPLICATION AFTER OCTOBER 1, 2003 ARE | | | REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 6A) NOT A CODE ISSUE BUT REFRENCED IN | | | THE PLANS THE ARCHITECT OF RECORD IS TO | | | REVIEW AND APPROVE ALL COMPONENTS & | | | CLADDING. | | | | | | 6B) THE PRODUCT APPROVALS FOR PGT FIXED | | | WINDOWS (2) REPORTS SUBMITTED ONE FOR | | | LARGE MISSLE RATED GLASS/NONRATED OR NOT | | | RATED AND A SECOND REPORT F6000 | | | NONRATED, EACH SECTION HAS DIFFERENT | | | PRESSURES, INDICATE WHICH REPORT IS TO | | | BE USED AND WHICH GLAZING SYSTEM WITH | | | ASSOCIATED PRESSURES. | | | THE PRODUCT APPROVAL WITH LARGE | | | MISSLE RATED GLASS INDICATE WHICH | | | GLAZING SYSTEM THAT SHALL BE USED, THERE | | | ARE MORE THAN ONE GLAZING SYSTEM WITH | | | DIFFERENT ASSOCIATED PRESSURES.. | | | | | | 6C) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3) IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | 1) WINDOWS FIXED OR(STOREFRONT- NOT | | | SUBMITTED W/ LARGE MISSLE IMPACT) | | | 2) MULLIONS- NOT SUBMITTED | | | 3) EXTERIOR DOORS 1 REPORT ONLY!!! | | | 4) GARAGE DOORS- NOT SUBMITTED | | | 5) STORM SHUTTERS- NOT SUBMITTED | | | 6) ROOFING ASSEMBLIES | | | | | | 7)FL BLD CODE 104.2.1.2* | | | ADDITIONAL INFORMATION REQUIRED, | | | DISCREPANCY, A9.03 THE WINDOW SCHEDULE | | | INDICATES THE USE OF IMPACT GLAZING, | | | THEN NOTE #1 INDICATES THE USE OF STORM | | | SHUTTERS, WHICH SHALL BE USED?CLARIFY. | | | | | | 8A)COMMENT #16 FROM THE PREVIOUS REVIEW: | | | A9.03 PLANS INDICATE THE USE OF STORM | | | SHUTTERS, SEE CITY INTERPRETATION ON THE | | | STANDARD FOR HURRICANE MISSLE IMPACT | | | PROTECTION, QUESTION #13, DEALING WITH | | | THE "PRESTORMHURRICANE PREPAREDNESS | | | PLAN" SUBMIT WITH NEXT REVIEW. | | | | | | 8B) PROVIDE STORM PANEL INFORMATION WITH | | | INSTALLATION SCHEDULE AND KEY PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE USED | | | FOR ALL NON-IMPACT GLAZING.INDICATE | | | WHERE SHUTTERS SHALL BE STORED.FBC | | | 1606.1.4. | | | | | | 8C) FL BLD CODE 2001 SECTION 103.6, | | | 1606.1.4, 1707.4 & 3401.7.2.4. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | | | | 9) BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-02-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-02-16 |
Time |
12:57 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2005-02-16 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2005-02-16 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04110993 | | | ADD:5405 N HAVERHILL RD PH# 1 | | | CONT:NORTON CONSTRUCTION | | | TEL:(561)252-0590 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)COMMENT #5 FROM THE PREVIOUS REVIEW: | | | FBC* 105.3RESIDENT INSPECTOR. SUBMIT | | | INSPECTOR RESUME' AND LICENSE DOCUMENTS | | | TO HAROLD PISKURA, DIRECTOR OF THE | | | RESIDENT INSPECTOR PROGRAM.A RESIDENT | | | INSPECTOR PROGRAM IS REQUIRED, ON THIS | | | PROJECT, DUE TO ONE OR MORE OF THE | | | FOLLOWING: | | | - BUILDINGS/ADDITIONS OF TYPE I OR II | | | CONSTRUCTION | | | - ANY MAJOR STRUCTURAL ALTERATIONS | | | - STRUCTURES IN WHICH THE CONCRETE | | | DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F'C) IN EXCESS OF 3000 PSI | | | - PILE DRIVING | | | - BUILDINGS OVER 20,000 SQFT IN AREA | | | - BUILDINGS OVER 2 STORIES IN HEIGHT | | | - BUILDING/STRUCTURES OF UNUSUAL DESIGN | | | OR METHODS OF CONSTRUCTION | | | | | | 3) COMMENT #6 FROM THE PREVIOUS REVIEW: | | | 106.4.2 STORAGE & FACTORY- INDUS- TRIAL | | | OCCUPANCIES. IT SHALL BE THE | | | RESPONSIBILITY OF THE OWNER, AGENT, | | | PROPIETOR OR OCCUPANT OF GROUP S AND | | | GROUP F OCCUPANCIES, OR ANY OCCUPANCY | | | WHERE EXCESSIVE FLOOR LOADING IS LIKELY | | | TO OCCUR, TO EMPLOY A COMPETENT ARCHI- | | | TECT OR ENGINEER IN COMPUTING THE SAFE | | | FLOOR LOAD CAPACITY. ALL SUCH COMPUTA- | | | TIONS SHALL BE ACCOMPANIED BY AN AFFA- | | | DAVIT FROM THE ARCHITECT OR ENGINEER | | | STATING THE SAFE ALLOWABLE FLOOR LOADS | | | ON EACH FLOOR IN POUNDS PER SQ FT.THE | | | COMPUTATIONS & AFFADAVIT SHALL BE FILED | | | AS A PERMANENT RECORD OF THE BLDG DEPT. | | | | | | 4) COMMENT #8 FROM THE PREVIOUS REVIW: | | | PLEASE PROVIDE THE MINIMUM BLDG DESIGN, | | | THIS BLDG IS DESIGNED? | | | A0.01 UNDER ALLOWABLE HEIGHT AND | | | BUILDING AREA INDICATES 72,000 SQ FT | | | BUT THE BLDG TYPE: IS TYPE V UNPROTECTED | | | FULLY SPRINKLERED. THIS RATING IS GOOD | | | FOR ONLY 48,000 SQ FT.AGAIN HOW ARE YOU | | | COMPLYING WITH TABLE 500? THE TOTAL SQ | | | FT( INCLUDING MEZZANINE) IS 65,199 SQ | | | FT. IF AREA INCREASES WERE TAKEN PROVIDE | | | THE CALCULATION! DO NOT FORGET THE AREA | | | OF THE MEZZANINE TO BE INCLUDED FOR | | | TOTAL AREA OF BUILDING. SEE DEFINITION | | | OF AREA GROSS. | | | | | | 5) COMMENT #9 FROM THE PREVIOUS REVIEW | | | DEALS WITH TERMIT PROTECTION | | | REQUIREMENTS FOUND IN CHAPTERS OTHER | | | THAN FOR TREATMENT OF SOILS: | | | 1503.4.4 PROTECTION AGAINST DECAY & | | | TERMITES. CONDENSATE LINES & ROOF DOWN | | | SPOUTS SHALL DISCHARGE AT LEAST 1 FT. | | | AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EX- | | | TENSIONS, OR SPLASH BLOCKS. | | | | | | 6A)COMMENT #15 FROM THE PREVIOUS REVIEW: | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT | | | APPLICATION AFTER OCTOBER 1, 2003 ARE | | | REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 6B) NOT A CODE ISSUE BUT REFRENCED IN | | | THE PLANS THE ARCHITECT OF RECORD IS TO | | | REVIEW AND APPROVE ALL COMPONENTS & | | | CLADDING. | | | | | | 6C) THE PRODUCT APPROVALS FOR PGT FIXED | | | WINDOWS (2) REPORTS SUBMITTED ONE FOR | | | LARGE MISSLE RATED GLASSOR NOT RATEDAND | | | A SECOND REPORT F6000, EACH SECTION HAS | | | DIFFERENT PRESSURES, INDICATE WHICH | | | REPORT IS TO BE USED AND WHICH GLAZING | | | SYSTEM WITH ASSOCIATED PRESSURES. | | | | | | 6D) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | 1) WINDOWS FIXED OR(STOREFRONT- NOT | | | | | | SUBMITTED) | | | 2) MULLIONS- NOT SUBMITTED | | | 3) EXTERIOR DOORS | | | 4) GARAGE DOORS- NOT SUBMITTED | | | 5) STORM SHUTTERS- NOT SUBMITTED | | | 6) ROOFING ASSEMBLIES | | | | | | 7)FL BLD CODE 104.2.1.2* | | | ADDITIONAL INFORMATION REQUIRED, | | | DISCREPANCY, A9.03 THE WINDOW SCHEDULE | | | INDICATES THE USE OF IMPACT GLAZING, | | | THEN NOTE #1 INDICATES THE USE OF STORM | | | SHUTTERS, WHICH SHALL BE USED?CLARIFY. | | | | | | 8A)COMMENT #16 FROM THE PREVIOUS REVIEW: | | | A9.03 PLANS INDICATE THE USE OF STORM | | | SHUTTERS, SEE CITY INTERPRETATION ON THE | | | STANDARD FOR HURRICANE MISSLE IMPACT | | | PROTECTION, QUESTION #13, DEALING WITH | | | THE "PRESTORMHURRICANE PREPAREDNESS | | | PLAN" SUBMIT WITH NEXT REVIEW. | | | | | | 8B) PROVIDE STORM PANEL INFORMATION WITH | | | INSTALLATION SCHEDULE AND KEY PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE USED | | | FOR ALL NON-IMPACT GLAZING.INDICATE | | | WHERE SHUTTERS SHALL BE STORED.FBC | | | 1606.1.4. | | | | | | 8C) FL BLD CODE 2001 SECTION 103.6, | | | 1606.1.4, 1707.4 & 3401.7.2.4. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | | | | 9) BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-12-14 |
Time |
15:41 |
Rev Time |
8.00 |
| Received By |
jwitmer |
Date |
2004-12-14 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2004-12-14 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04110993 | | | ADD: XXXXX N HAVERHILL RD | | | CONT: NORTON CONSTRUCTION | | | TEL: (561)252-0590 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1A) THE ADDRESS ON THE PERMIT | | | APPLICATION DOES NOT TIE TO ANY LOTIN | | | THIS SUBDIVISION NOR IN THIS ADDRESS | | | RANGE. | | | 1B) PHASE# 1 OR BUILDING# 1, CROSSES | | | PROPERTY LINES.THE PROPOSED BUILDING | | | STRUCTURE TRANSGRESSES LEGAL BOUNDARY | | | LINES BETWEEN THE LOTS WHICH COMBINE TO | | | FORM 'THE SITE'.A 'UNITY OF TITLE' | | | SHALL BE RECORDED AT THE COUNTY | | | COURTHOUSE. SUBMIT A COPY OF THE | | | RECORDED 'UNITY OF OF TITLE' DOCUMENT | | | SO | | | THAT FBC TABLE 600 BOUNDARY LINE | | | REQUIREMENTS MAY BE DEEMED NOT | | | APPLICABLE. | | | 1C) ONCE THE UNITY OF TITLE IS RECORDED | | | SUPPLY JOHN HIGGINS WITH RECORDED COPY | | | AND RECEIVE THE ADDRESS FOR THIS | | | PROJECT. (561)822-1239. | | | 1D) THESITE ENTRANCE IS USUALLY WHERE | | | | | | THE PROJECT IS ADDRESSED FROM.IT | | | APPEARS | | | THAT THE ENTRY IS AT THE CUL-DE-SAC AT | | | THE END OF MCMILLIAN WAY. | | | | | | 2) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 3) FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITLY KNOWN OR IS IN | | | QUESTION | | | THE BUILDING OFFICIAL MAY REQUIRE | | | EXPLOR | | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | | TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA. | | | | | | 4) FL BLD CODE CHAP 13 ENERGY EFFICENCY | | | PROVIDE ENERGY CALS/ W MANUAL "J" | | | | | | 5 ) FBC* 105.3RESIDENT INSPECTOR. | | | SUBMIT INSPECTOR RESUME' AND LICENSE | | | DOCUMENTS TO HAROLD PISKURA, DIRECTOR | | | OF | | | THE RESIDENT INSPECTOR PROGRAM.A | | | RESIDENT INSPECTOR PROGRAM IS REQUIRED, | | | ON THIS PROJECT, DUE TO ONE OR MORE OF | | | THE FOLLOWING: | | | - BUILDINGS/ADDITIONS OF TYPE I OR II | | | CONSTRUCTION | | | - ANY MAJOR STRUCTURAL ALTERATIONS | | | - STRUCTURES IN WHICH THE CONCRETE | | | DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F'C) IN EXCESS OF 3000 PSI | | | - PILE DRIVING | | | - BUILDINGS OVER 20,000 SQFT IN AREA | | | - BUILDINGS OVER 2 STORIES IN HEIGHT | | | - BUILDING/STRUCTURES OF UNUSUAL | | | DESIGN | | | OR METHODS OF CONSTRUCTION | | | | | | 6) 106.4.2 STORAGE & FACTORY- INDUS- | | | TRIAL OCCUPANCIES. IT SHALL BE THE | | | RESPONSIBILITY OF THE OWNER, AGENT, | | | PROPIETOR OR OCCUPANT OF GROUP S AND | | | GROUP F OCCUPANCIES, OR ANY OCCUPANCY | | | WHERE EXCESSIVE FLOOR LOADING IS LIKELY | | | TO OCCUR, TO EMPLOY A COMPETENT ARCHI- | | | TECT OR ENGINEER IN COMPUTING THE SAFE | | | FLOOR LOAD CAPACITY. ALL SUCH COMPUTA- | | | TIONS SHALL BE ACCOMPANIED BY AN AFFA- | | | DAVIT FROM THE ARCHITECT OR ENGINEER | | | STATING THE SAFE ALLOWABLE FLOOR LOADS | | | ON EACH FLOOR IN POUNDS PER SQ FT.THE | | | COMPUTATIONS & AFFADAVIT SHALL BE FILED | | | AS A PERMANENT RECORD OF THE BLDG DEPT. | | | | | | 7) 106.4.3.SIGNS REQUIRED. IN EVERY | | | BUILDING OR PART OF A BUILDING USED FOR | | | STORAGE, INDUSTRIAL OR HAZARDOUS PUR- | | | POSES, THE SAFE FLOOR LOADS, AS | | | REVIEWED | | | BY THE BUILDING OFFICIAL ON THE PLAN, | | | SHALL BE MARKED ON PLATES OF APPROVED | | | DE | | | SIGN WHICH SHALL BE SUPPLIED & SECURELY | | | AFFIXED BY THE OWNER OF THE BUILDING IN | | | A CONSPICUOUS PLACE IN EACH STORY TO | | | WHICH THEY RELATE. SUCH PLATES SHALL | | | NOT | | | BE REMOVEDOR DEFACED, & IF LOST, | | | REMOVED THE OWNER OF THE BUILDING SHALL | | | REPLACE THEM. | | | | | | 8)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | PROVIDE WHAT THE MINIMUM BLDG DESIGN IS | | | UNDER TABLE 500? PLANS INDICATE BOTH | | | FIRE SPRINKLER AS WELL AS 1 HR FIRE | | | RATINGS, WERE GENERAL AREA INCREASES | | | CONSIDERED INTO THE DESIGN? | | | | | | 9) 1503.4.4 PROTECTION AGAINST DECAY & | | | TERMITES. CONDENSATE LINES & ROOF DOWN | | | SPOUTS SHALL DISCHARGE AT LEAST 1 FT. | | | AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EX- | | | TENSIONS, OR SPLASH BLOCKS. | | | | | | 10) 1511.7 ROOF MOUNTED MECHANICAL UNIT | | | S SHALL BE MOUNTED ON CURBS RAISED A | | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. | | | MECH. 301.13 WIND RESISTANCE MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUP PORTS | | | THAT | | | ARE EXPOSED TO WIND SHALL BE DESIGNED | | | AND INSTALLED TO RESIST THE WIND | | | PRESSURES ON THE EQUIPMENT & THE | | | SUPPORTS AS DETERMINED IN ACCORDANCE | | | WITH THE FL BLD CODE. THIS MAY BE | | | ACCOMP | | | LISHED BY DESIGN OR BY APPLICATION OF | | | SECTION 301.13.1. | | | | | | 11)301.13.1 GROUND MOUNTED A/C | | | UNITS: | | | GROUND-MOUNTED UNITS FOR R3 RESIDENTIAL | | | APPLICATIONS MAY BE ANCHORED WITH # 14 | | | SCREWS WITH GASKETED WASHERS ACCORDING | | | TO THE FOLLOWING: | | | 1) FOR UNITS WITH SIDES LESS THAN 12", | | | ONE SCREW SHALL BE USED AT EACH SIDE OF | | | THE UNIT. | | | 2) FOR UNITS BETWEEN 12" & 24", TWO | | | SCREWS SHALL BE USED PER DIDE. | | | 3) FOR UNITS BETWEEN 24" & 36", THREE | | | SCREWS SHALL BE USED PER SIDE. | | | 4) FOR UNITS GREATER THAN 36" OR 5 | | | TONS | | | ANCHORAGE SHALL BE DESIGN IN ACCORDANCE | | | WITH 301.13. (140 MPH). | | | | | | 12) A8.02 DETAILS 8&9 INDICATE CANVAS | | | AWNINGS, UNDER SEPERATE PERMIT. | | | | | | 13) A9.03 NOTE 8 CORRECT TO F.B.C. | | | SECTION. | | | | | | 14) A8.02 PROJECT MONUMENT SIGN UNDER | | | SEPERATE PERMIT, SEE COPY OF CITY | | | ORDINANCE ON MONUMENT SIGNS CONCERNING | | | ADDRESSING. | | | | | | 15)FL BLD CODE 1606.1.5: COMPONENTS | | | & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS | | | B) MULLIONS | | | C) EXTERIOR DOORS | | | D) GARAGE DOORS | | | E) STORM SHUTTERS | | | F) ROOFING ASSEMBLIES, UNDERLAYMENTS, | | | BUILT UP OR MODIFIED SYSTEMS | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 16) PLANS INDICATE THE USE OF STORM | | | SHUTTERS. SEE CITY INTERPRETATION ON | | | STANDARD FOR HURRICANE MISSLE IMPACT | | | PROTECTION, SEE ATTACHMENT, QUESTION | | | 13. | | | | | | PROVIDE STORM PANEL INFORMATION WITH | | | INSTALLATION SCHEDULE AND KEY PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE | | | USED | | | FOR ALL NON-IMPACT GLAZING.FBC | | | 1606.1.4. | | | FL BLD CODE 2001 SECTION 103.6, | | | 1606.1.4,1707.4& 3401.7.2.4. | | | PROCEDURES: 1(B) A COMPLETE | | | INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL | | | PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | | | | 17) CORRECT S2.01 ASCE 7-98, V= 140 MPH | | | WIND ZONE, EXPOSURE "B". | | | | | | 18) S2.01 DOESN'T MENTION TERMITE SOIL | | | PRETREATMENT.105.11. | | | | | | 19)A1.01 PLANS TO PROVIDE AT LEAST ONE | | | ACCESSIBLE ROUTE CONNECTING ACCESSIBLE | | | BUILDINGS, FACILITIES, ELEMENTS, AND | | | SPACES THAT ARE ON THE SAME SITE. | | | SEE 11-4.3.2(2) | | | | | | 20)BEFORE A PERMIT TO CONSTRUCT, | | | MAY BE ISSUED, IMPACT FEES MUST BE PAID | | | TO PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2006-05-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-12 |
Time |
14:28 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-05-12 |
Time |
14:28 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2006-02-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-10 |
Time |
17:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-10 |
Time |
17:48 |
Sent To |
PC |
|
| Notes |
| 2006-02-10 00:00:00 | REV'S FOR RISER DIAGRAM AND PANEL | | | SCHEDULES. | | | E-1.10, 1.10A AND 1.12 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-31 |
Time |
19:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-31 |
Time |
17:50 |
Sent To |
FIRE |
|
| Notes |
| 2006-01-31 00:00:00 | ******* UNSAT ***** | | | | | | 1)NOTE: PLEASE CORRELATE RISER AND | | | FEEDERS FOR TENANT MAINS 1 AND 10. | | | PLEASE SEE THESE ARE SHOWN AS 150A'S, | | | YET FEEDER NOTE #9 INDICATES 32'S. AWG. | | | PLEASE SEE 310.16,240.4 | | | | | | 2)NOTE: PLEASE SEE PANEL SCHEDULE FOR | | | UNIT #10 INDICATES THIS PANEL AS 100A'S? | | | SHEET E-1.12 | | | | | | 3)NOTE: PLEASE SEE MAIN ELECTRICAL ROOM | | | LAYOUT ON 1.10A WHICH SHOWS TWO MAINS | | | WITH CONDUIT JOINING BOTH MAINS. PLEASE | | | VERIFY THIS AS EACH SEEM TO FEED | | | DIFFERENT GUTTERS ETC? | | | 215.5 | | | | | | PLEASE KNOW, DEPENDING ON FIRE REVIEW, | | | SHEETS FOR UNITS MAY BE STAMPED AND | | | PASSED FOR REVIEW, HOWEVER SHEETS | | | MENTIONED ABOVE SHALL BE REMOVED. | | | CORRECTED REVISIONS WILL BE REQUIRED TO | | | BE SUBMITTED SEPARTELY. | | | IF FIRE REVIEW PROCEEDS INTO A "P" | | | STATUS, UNIT LAYOUTS WILL BE STAMPED FOR | | | ROUGH INSPECTIONS. *** PLEASE KEEP IN | | | MIND, PLANS SUBMITTED ARE STILL SHOWING | | | SHEETS WHICH INDICATE "OPTIONS", PLEASE | | | KNOW, ALL "OPTIONS" MUST BE REVISED TO | | | THE INDIVIDUAL UNITS BEFORE ROUGH. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF NEW SHEETS ADDRESSING | | | COMMENTS AS NOTED ABOVE ARE SUBMITTED | | | AND INSERTED INTO SETS BEFORE FIRE | | | REVIEW IS COMPLETED, THEN PLEASE CALL TO | | | SET UP A MEETING TO DO SO. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-01-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-12 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-12 |
Time |
07:13 |
Sent To |
|
|
| Notes |
| 2006-01-12 00:00:00 | ********** UNSAT ************ | | | | | | | | | 1)NOTE: RISER DIAGRAM AHS NOW BEEN | | | COMPLETELY REVISED. PLEASE SEE MAINS | | | HAVE NOW BEEN INCREASED AND VOLTAGES | | | HAVE BEEN CHANGED FROM 480V TO 208V. | | | PLEASE SEE NO REVISED PANELS, PANEL | | | SCHEDULES, OR LOAD CALCUALTIONS WERE | | | SUBMITTED FOR THIS. | | | 215.5 | | | | | | 2)NOTE: PLEASE SEE 250.66 FOR MIN SIZING | | | FOR GROUNDING ELECTRODE CONDUCTOR. | | | PLEASE SEE A 2/0 MIN APPEARS TO BE | | | REQUIRED. PLEASE SEE THIS IS REQUIRED | | | FOR ALL MAINS. (4). | | | | | | 3)NOTE: PLEASE SEE AN "EQUIPMENT | | | GROUNDING CONDUCTOR" IS NOW BEING SHOWN | | | FROM METER TO MAIN. | | | PLEASE SEE 250.6, THIS EQP GRND SHOULD | | | ONLY BE INSTALLED AFTER THE FIRST MEANS | | | OF DISCONNECT. | | | | | | 4)NOTE: PLEASE INDICATE THE | | | SIZE/AMPERAGES OF METERS. PLEASE SEE | | | METER FOR SPACE 7/8 NOW APPEAR TO BE | | | FEEDING TWO MAINS. PLEASE ALSO SEE | | | CONDUCTORS FOR DISCONNECT #2 SEEMS TO BE | | | FEEDING THROUGH THE OTHER MAIN. PLEASE | | | SEE MAIN DISCONNECT IS BEING USED AS A | | | RACEWAY FOR 2ND MAIN. | | | PLEASE VERIFY AS METER SHOULD BE DOUBLE | | | LUGGED FOR THIS INSTALLATION. | | | | | | | | | 5)NOTE: PLEASE SEE HOUSE PANEL AND MAIN | | | SEEMS TO BE STRICKEN FROM PLANS WITH A | | | HIGHLIGHTER FOR SOME REASON? | | | PLEASE VERIFY. | | | 215.5 | | | | | | ** PLEASE KNOW ALL OPTIONS FOR UNITS AND | | | REVISIONS SHOULD BE SUBMITTED FOR REVIEW | | | AND ON JOB-SITE BEFORE ANY ROUGH | | | ELECTRICAL INSPECTION IS CALLED IN. | | | PLEASE SEE ORIGINAL PLANS WERE STAMPED | | | FOR THIS. | | | THIS IS ONLY A NOTE, AS IT HAS TO THE | | | ATTENTION OF THIS OFFICE THAT ROUGHS ARE | | | BEING CALLED IN FOR INSPECTIONS WITHOUT | | | HAVING THE LATEST UPDATED STMAPED PLANS | | | ON JOBSITE FOR INSPECTION. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW ALONG WITH OTHER MISSING | | | INFORMATION FOR REVIEW. IF THERE ARE ANY | | | QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-11-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-14 |
Time |
08:49 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2005-11-10 |
Time |
21:42 |
Sent To |
|
|
| Notes |
| 2005-11-14 00:00:00 | ************ UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE MAIN ELECTRICAL ROOM | | | IS NOW BEING SHOWN AT A DETACHED BLDG. | | | PLEASE SEE 225.31 -225.39 FOR FEEDERS | | | COMING INTO MAIN BLDG. A DISCONNECTING | | | MEANS FOR EACH IS REQUIRED AND ALL MAINS | | | ARE REQUIRED TO BE GROUPED ETC. 252.31, | | | 225.34. | | | | | | 2)NOTE: PLEASE SEE MIN CLEARENCES PER | | | 110.26 ARE NOT MET IN THIS NEW | | | ELECTRICAL ROOM SHOWN. | | | PLEASE SEE SCALE AS SHOWN MENTIONS | | | 1/2"PER FT. | | | | | | 3)NOTE: PLEASE PROVIDE GROUNDING | | | ELECTRODE SYSTEM AT DETACHED MAIN BLDG. | | | PER 250.32 | | | | | | 4)NOTE: PLEASE PROVIDE A REVISED RISER | | | DIAGRAM WITH CHANGES AS SHOWN AND | | | CHANGES TO BE MADE BY THE ABOVE | | | COMMENTS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASEDO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2005-11-10 00:00:00 | *********NOTES*** | | | | | | | | | PLANS TO BE FAILED AND COMMENTS TO | | | FOLLOW. | | | DO NOT CONSTRUCT DETACHED ELECTRICAL | | | ROOM, AS SHOWN THIS WILL NOT PERMITTED. | | | | | | | | | ** CALLED OWNER'S REP, FOR ELECTRICAL | | | COMMENTS TO FOLLOW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-08-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-15 |
Time |
21:29 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2005-08-15 |
Time |
20:53 |
Sent To |
|
|
| Notes |
| 2005-08-15 00:00:00 | IN ELEC FOR REVIEW. | | | REV'S, | | | | | | REVISED CIRCUITING, LTS, CU'S ETC, | | | SHEETS: | | | 1.02,1.04,1.05,1.06,1.07,& 1.12 | | | ELECTRICAL SHEETS STAMPED FOR THREE | | | SETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-14 |
Time |
17:53 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2005-02-11 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2005-02-14 00:00:00 | ELECTRICAL PLANS STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-12-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-02 |
Time |
09:09 |
Rev Time |
5.00 |
| Received By |
dpalmer |
Date |
2004-12-02 |
Time |
06:43 |
Sent To |
|
|
| Notes |
| 2004-12-02 00:00:00 | IN ELEC FOR REVIEW. | | | ************** UNSAT ****************** | | | | | | WAREHOUSE PROJECT: | | | 5405 N. HAVERHILL | | | 04110993 | | | | | | REVIEWED FOR CODE COMPLIANCE UNDER 2002 | | | NEC. | | | | | | 1)NOTE: PLEASE SEE UNIT #2, SHOWS TO BE | | | FUTURE UNIT, YET MEZZ FLR AREA SHOWS | | | LTS, BUT NOT TO ANY CIRCUITS? | | | PLEASE CLARIFY. | | | | | | 2)NOTE: PLEASE SEE UNITS #'S 13,26 | | | INDICATE SHOW ROOMS. PLEASE SEE 210.62 | | | AT LEAST ONE RECEPTACLE OUTLET SHALL BE | | | INSTALLED DIRECTLY ABOVE A SHOW WINDOW | | | FOR EACH 3.7 LINEAR M (12 FT) OR MAJOR | | | FRACTION THEREOF OF SHOW WINDOW AREA | | | MEASURED HORIZONTALLY AT ITS MAXIMUM | | | WIDTH. | | | SHOW WINDOWS USUALLY EXTEND FROM FLOOR | | | TO CEILING FOR MAXIMUM DISPLAY. TO | | | DISCOURAGE FLOOR RECEPTACLES AND | | | UNSIGHTLY EXTENSION CORDS LIKELY TO | | | CAUSE PHYSICAL INJURY, RECEPTACLES MUST | | | BE INSTALLED DIRECTLY ABOVE A SHOW | | | WINDOW, AND ONE RECEPTACLE IS REQUIRED | | | FOR EVERY 12 LINEAR FT OR ?MAJOR | | | FRACTION THEREOF? (6 FT OR MORE). SEE | | | 220.3(B)(7) AND 220.12(A) FOR | | | INFORMATION REGARDING LOAD COMPUTATIONS | | | FOR SHOW WINDOWS. | | | IT IS NOTEDON ONE OF THE PANEL | | | SCHEDULES FOR L-26 "SHOWROOM RECEPTS, | | | HOWEVER THESE APPEAR TO BE CLOSE TO FLR | | | LEVEL? | | | | | | 3)NOTE: PLEASE INDICATE CIRCUITING FOR | | | ALL A/C EQUIPMENT. PLEASE SEE THERE ARE | | | SOME A/C COND UNITS SHOWN ON ROOF, YET | | | THESE DO NOT SHOW ANY HOOK-UPS, CIRCUITS | | | ETC.? | | | PLEASE SEE 440.11 WHICH REQUIRES | | | DISCONNECTING MEANS CAPABLE OF | | | DISCONNECTING AIR-CONDITIONING AND | | | REFRIGERATING EQUIPMENT, INCLUDING | | | MOTOR-COMPRESSORS AND CONTROLLERS FROM | | | THE CIRCUIT CONDUCTORS. | | | | | | 4)NOTE: PLEASE SEE ALL OPTS AS SHOWN ON | | | E-1.08. IF ANY OF THESE OPTIONS ARE | | | TAKENAND DIFFER FROM PLANS SHOWN, THEN | | | PLANS WILL BE REQUIRED TO BE REVISED | | | BEFORE ROUGH FOR WHICH OPTION IS TAKEN | | | FOR WHICH UNIT. THIS IS ONLY A NOTE | | | GIVEN AT THIS TIME. | | | | | | 5)NOTE: PLEASE SEE 250.50 FOR REQUIRED | | | POINTS OF ATTACHMENT FOR GROUNDING | | | ELECTRODE SYSTEM. | | | IF AVAILABLE ON THE PREMISES AT EACH | | | BUILDING OR STRUCTURE SERVED, EACH ITEM | | | IN 250.52(A)(1) THROUGH (A)(6) SHALL BE | | | BONDED TOGETHER TO FORM THE GROUNDING | | | ELECTRODE SYSTEM. CONCRETE-ENCASED | | | ELECTRODE,METAL UNDERGROUND WATER PIPE, | | | ETC. | | | | | | 6)NOTE: PLEASE SEE THERE IS AN EQUIPMENT | | | GROUNDING CONDUCTOR SHOWN FROM FPL | | | TRANSFORMER TO MAIN # 2. | | | PLEASE SEE 250.6,250.24 | | | OBJECTIONABLE CURRENT OVER GROUNDING | | | CONDUCTORS. | | | A PREMISES WIRING SYSTEM SUPPLIED BY A | | | GROUNDED AC SERVICE SHALL HAVE A | | | GROUNDING ELECTRODE CONDUCTOR CONNECTED | | | TO THE GROUNDED SERVICE CONDUCTOR, AT | | | EACH SERVICE, IN ACCORDANCE WITH | | | 250.24(A)(1) THROUGH (A)(5). | | | THE CONNECTION SHALL BE MADE AT ANY | | | ACCESSIBLE POINT FROM THE LOAD END OF | | | THE SERVICE DROP OR SERVICE LATERAL TO | | | AND INCLUDING THE TERMINAL OR BUS TO | | | WHICH THE GROUNDED SERVICE CONDUCTOR IS | | | CONNECTED AT THE SERVICE DISCONNECTING | | | MEANS. | | | | | | 7)NOTE: PLEASE SEE NOTE #9 FOR RISER | | | DIAGRAM ON E 1.10. | | | PLEASE SEE 250.122 FOR SIZING OF THE | | | EQUIPMENT GROUNDING CONDUCTOR. | | | COPPER, ALUMINUM, OR COPPER-CLAD | | | ALUMINUM EQUIPMENT GROUNDING CONDUCTORS | | | OF THE WIRE TYPE SHALL NOT BE SMALLER | | | THAN SHOWN IN TABLE 250.122 BUT SHALL | | | NOT BE REQUIRED TO BE LARGER THAN THE | | | CIRCUIT CONDUCTORS SUPPLYING THE | | | EQUIPMENT. | | | SOME SHOWN AS #10 ON 100A OCP ETC. | | | PLEASE SEE NOTE #17. | | | | | | 8)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | EQUIPMENT SIZES. | | | RISER SHOWS SOME 100A FEEDS TO 60A | | | DISCONNECTING MEANS. PLEASE SEE | | | EQUIPMENT MUST BE RATED FOR FEED. | | | PLEASE SEE 1-6,14-19= 100A FEEDS TO 60A | | | DISC'S. #20&21 150A FEEDS TO 100A | | | DISC'S.???? | | | | | | 9)NOTE: PLEASE VERIFY SERVICE LOCATION | | | ON PLANS. THIS COULD NOT BE LOCATED. | | | PLEASE SEE 230.72 FOR GROUPING OF | | | MAINS. | | | PLEASE ALSO SEE 230.70 THE SERVICE | | | DISCONNECTING MEANS SHALL BE INSTALLED | | | AT A READILY ACCESSIBLE LOCATION EITHER | | | OUTSIDE OF A BUILDING OR STRUCTURE OR | | | INSIDE NEAREST THE POINT OF ENTRANCE OF | | | THE SERVICE CONDUCTORS. | | | THE TWO TO SIX DISCONNECTS AS PERMITTED | | | IN 230.71 SHALL BE GROUPED. EACH | | | DISCONNECT SHALL BE MARKED TO INDICATE | | | THE LOAD SERVED. | | | | | | 10)NOTE: PLEASE SHOW LOCATION OF | | | DISCONNECTS, TRANSFORMERS IN UNITS. | | | THESE COULD NOT BE LOCATED ON PLANS. | | | 215.5 | | | | | | 11)NOTE: PLEASE SEE 250.30 FOR GROUNDING | | | OF TRANSFOMERS. | | | GROUNDING SEPARATELY DERIVED | | | ALTERNATING-CURRENT SYSTEMS. | | | A SEPARATELY DERIVED AC SYSTEM THAT IS | | | GROUNDED SHALL COMPLY WITH 250.30(A)(1) | | | THROUGH (6). PLEASE SHOW THE ATTACHMENT | | | ON RISER. | | | | | | 12)NOTE: PLEASE SHOW ALL CONTINUOUS | | | LOADS AT 125%.FEEDERS SHALL BE PROTECTED | | | AGAINST OVERCURRENT IN ACCORDANCE WITH | | | THE PROVISIONS OF PART I OF ARTICLE 240. | | | WHERE A FEEDER SUPPLIES CONTINUOUS LOADS | | | OR ANY COMBINATION OF CONTINUOUS AND | | | NONCONTINUOUS LOADS, THE RATING OF THE | | | OVERCURRENT DEVICE SHALL NOT BE LESS | | | THAN THE NONCONTINUOUS LOAD PLUS 125 | | | PERCENT OF THE CONTINUOUS LOAD. | | | THE AMPACITY OF THE SERVICE-ENTRANCE | | | CONDUCTORS BEFORE THE APPLICATION OF ANY | | | ADJUSTMENT OR CORRECTION FACTORS SHALL | | | NOT BE LESS THAN EITHER (1) OR (2). | | | LOADS SHALL BE DETERMINED IN ACCORDANCE | | | WITH ARTICLE 220. AMPACITY SHALL BE | | | DETERMINED FROM 310.15. THE MAXIMUM | | | ALLOWABLE CURRENT OF BUSWAYS SHALL BE | | | THAT VALUE FOR WHICH THE BUSWAY HAS BEEN | | | LISTED OR LABELED. | | | (1) THE SUM OF THE NONCONTINUOUS LOADS | | | PLUS 125 PERCENT OF CONTINUOUS LOADS | | | (2) THE SUM OF THE NONCONTINUOUS LOAD | | | PLUS THE CONTINUOUS LOAD IF THE | | | SERVICE-ENTRANCE CONDUCTORS TERMINATE IN | | | AN OVERCURRENT DEVICE WHERE BOTH THE | | | OVERCURRENT DEVICE AND ITS ASSEMBLY ARE | | | LISTED FOR OPERATION AT 100 PERCENT OF | | | THEIR RATING. | | | THIS WILL BE FOR INDIVIUAL UNITS AND | | | HOUSE PANELS. | | | | | | 13)NOTE: PLEASE SHOW LOAD CALCULATIONS | | | PER EACH MAIN. | | | PLEASE SHOW LOAD CALCULATIONS, PLEASE | | | SHOW PER 220.3,220.10,220.11,220.13 | | | ETC. | | | PLEASE ALSO SHOW ALL CONTINOUS LOADS | | | AT 125% PER 215.3,230.42 | | | PLEASE ALSO INDICATE LOAD FOR EACH | | | PANEL, ON THAT PARTICULAR PANEL | | | SCHEDULE. | | | PLEASE SEE THERE IS A PANEL "X" WHICH IS | | | NOTED FOR SOME TYPICAL UNITS, HOWEVER | | | THERE ARE CIRCUITS AND LOADS INDICATED | | | ON SOME OF THESE UNITS WHICH ARE NOT | | | SHOWN ON THIS "TYPICAL" PANEL | | | SCHEDULE.? | | | PLEASE CORRELATE. ONE UNIT NOTED,#13 | | | | | | 14)NOTE: PLANS CONTAIN NOTES IN MANY | | | LOCATION WITH REFERENCE TO EXISTING | | | SERVICE AND EXISTING PHASE 1, YET THE | | | TITLE BLOCK AND PLANS REFERENCE THIS AS | | | BEING PHASE -1. ?? | | | PLEASE SEE LOAD CALCS INDICATE | | | "EXISTING" BUILDING CAPACITY??? | | | PLEASE SEE E1.10,1.09 | | | | | | 15)NOTE: PLEASE SEE SPRINKLER MONITOR | | | PANEL DETAIL. PLEASE SEE MISSING | | | EQUIPMENT GROUNDING PER 250.110 | | | EXPOSED NON?CURRENT-CARRYING METAL PARTS | | | OF FIXED EQUIPMENT LIKELY TO BECOME | | | ENERGIZED SHALL BE GROUNDED. | | | | | | 16)NOTE: PLEASE CLARIFY IF FIRE | | | SPRINKLER PIPING IS METAL? PLEASE SEE | | | 250.104 .THE METAL WATER PIPING SYSTEM | | | SHALL BE BONDED AS REQUIRED IN (1), (2), | | | (3), OR (4) OF THIS SECTION. THE BONDING | | | JUMPER(S) SHALL BE INSTALLED IN | | | ACCORDANCE WITH 250.64(A), (B), AND (E). | | | THE POINTS OF ATTACHMENT OF THE BONDING | | | JUMPER(S) SHALL BE ACCESSIBLE. | | | | | | 17)NOTE: PLEASE SEE 408.16.EACH LIGHTING | | | AND APPLIANCE BRANCH-CIRCUIT PANELBOARD | | | SHALL BE INDIVIDUALLY PROTECTED ON THE | | | SUPPLY SIDE BY NOT MORE THAN TWO MAIN | | | CIRCUIT BREAKERS OR TWO SETS OF FUSES | | | HAVING A COMBINED RATING NOT GREATER | | | THAN THAT OF THE PANELBOARD. | | | PLEASE SEE MOST PANELS ARE SHOWN AS | | | MLO. | | | PLEASE ALSO SEE 240.21 | | | | | | 18)NOTE: PLEASE SEE MOST OF THE WATER | | | HEATERS SHOWN INDICATE 40A OCP FOR 6KW | | | UNITS WHICH IS FINE, YET THERE ARE A | | | COUPLE WITH 50A OCP. PLEASE SEE MAX OCP | | | FOR WATER HEATER IS 150%. PLEASE ADJUST | | | OCP.A BRANCH CIRCUIT SUPPLYING A FIXED | | | STORAGE-TYPE WATER HEATER THAT HAS A | | | CAPACITY OF 450 L (120 GAL) OR LESS | | | SHALL HAVE A RATING NOT LESS THAN 125 | | | PERCENT OF THE NAMEPLATE RATING OF THE | | | WATER HEATER. | | | IF THE BRANCH CIRCUIT SUPPLIES A SINGLE | | | NON?MOTOR-OPERATED APPLIANCE, THE RATING | | | OF OVERCURRENT PROTECTION SHALL BE 150% | | | MAX . 422.11 | | | | | | 19)NOTE: PLEASE SEE HOUSE PANEL "HP-1" | | | DOES NOT INDICATE FEED FOR TRANSFORMER | | | TO SPRINKLER MONT PANEL? | | | PLEASE SHOW. 215.5 | | | | | | 20)NOTE: PLEASE SEE ALL LOADS FOR ALL | | | AHU'S ON PANEL SCHEDULES. SOME SHOW | | | ACTUAL LOADS, SOMEDO NOT INDICATE FULL | | | KW LOAD FOR A/C UNITS?? | | | PLEASE CORRELATE ALL. | | | 215.5 | | | | | | 21)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | AND PANELS, DISCONNECTS. ETC. | | | PLEASE SEE UNIT #1 ON RISER INDICATES A | | | 400A DISC , YET UNIT #1IS 100A'S?? | | | SHOWS UNIT #2 AS 100A AND PLANS INDICATE | | | #2 AS 400A. | | | | | | 22)NOTE: PLEASE SEE A/C LOAD/DISC ON | | | PLANS, SHOWN FOR 50A LOAD? | | | | | | 23)NOTE: PLEASE SEE WIND LOADING FOR | | | POLES ARE LISTED AS 120MPH. PLEASE SEE | | | WE ARE UNDER THE FBC 140 MPH RATING. | | | PLEASE SUBMIT WIND LOADS AND SPECS FOR | | | SITE LIGHTING POLES FOR BLDG REVIEW. | | | THIS IS REQUIRED AT THIS TIME. PLEASE | | | ALSO ADJUST ELECTRICAL PLANS FOR 140 | | | MPH. | | | LIGHT POLES ARE ALSO NOTED AS MENTIONING | | | TO MATCH "EXISTING" PHASE-1 ?? | | | | | | 24)NOTE: PLEASE SEE "L-26" ON E1.12 DOES | | | NOT INDICATE BUS-RATING.? | | | 215.5 | | | | | | 25)NOTE: PLEASE ALSO SEE CIRCUITING OF | | | EM/EXT LTS. | | | PLEASE SEE 700.12E FOR CIRCUITING | | | REQUIREMENTS. | | | INDIVIDUAL UNIT EQUIPMENT FOR EMERGENCY | | | ILLUMINATION SHALL CONSIST THE BRANCH | | | CIRCUIT FEEDING THE UNIT EQUIPMENT SHALL | | | BE THE SAME BRANCH CIRCUIT AS THAT | | | SERVING THE NORMAL LIGHTING IN THE AREA | | | AND CONNECTED AHEAD OF ANY LOCAL | | | SWITCHES. | | | | | | 26)NOTE: PLEASE REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | PLEASE SEE BLDG REVIEW NOTES FOR | | | REQUIREMENTS OF POSSIBLE "SPEACIAL | | | INSPECTOR" AND NEEDING THREE (3) SETS OF | | | PLANS. | | | | | | 27)NOTE: PLEASE SEE POSSIBLE NOTES FROM | | | OTHER REVIEWER(S) WHICH MAY HAVE AN | | | AFFECT ON ELECTRICAL PLANS.(FIRE,BLDG | | | ETC) | | | | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2006-02-24 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2006-02-24 |
Time |
15:43 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2006-02-24 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2006-02-24 00:00:00 | PASSED: | | | | | | 1. REVIEWED FOR REVISION, SHEET C.4. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2006-01-27 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2006-01-27 |
Time |
14:40 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2006-01-27 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2006-01-27 00:00:00 | PASSED: | | | | | | 1. REVIEWED FOR REVISION SHEETS C.3,C.5A | | | C.9. | | | IF ANYQUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-11-29 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
mamini |
Date |
2004-11-29 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2004-11-29 00:00:00 | PASSED: | | | | | | 1. SEE PERMIT # 04110991 FOR | | | UNDERGROUND UTILITIES AND SITE WORK. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
P |
Date |
2006-02-16 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2006-02-16 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2006-02-16 |
Time |
10:04 |
Sent To |
E |
|
| Notes |
| 2006-02-16 00:00:00 | REVISION DATED 01-17-06 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2006-01-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-01-30 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-01-30 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2006-01-30 00:00:00 | REVISION DATED 12/5/05 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-11-16 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-11-16 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-06 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-06 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2005-09-06 00:00:00 | REVISION DATED 6/28/05 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-03-25 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-03-25 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-03-25 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-12-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-12-20 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-12-20 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2004-12-20 00:00:00 | 1. WET FIRE HYDRANTS ARE REQUIRED | | | PRIOR TO, DURING AND AFTER | | | CONSTRUCTION. | | | | | | 2. SUITABLE ROADS ARE TO BE PROVIDED | | | FOR FIRE AND PARAMEDICAL EQUIPMENT | | | DURING CONSTRUCTION. | | | | | | 3. KNOX-BOXES WILL BE REQUIRED. | | | | | | 4. PROPER CLEARANCES ARE REQUIRED TO | | | ALL PROPOSED FIRE HYDRANTS. | | | | | | 5. ELECTRONIC SWITCHES, CHAIN AND | | | LOCKS REQUIRED ON FIRE LINE BACKFLOW | | | DEVICE. | | | | | | 6. ALL PROPOSED MEZZANINES TO COMPLY | | | WITH THE FLORIDA BUILDING CODE AND | | | THE FLORIDA FIRE PREVENTION CODE WITH | | | REGARDS TO MEZZANINES. | | | | | | 7. BUILDING ADDRESS REQUIRED ON PROPER | | | ELEVATION. A MINIMUM OF AT LEAST 6" | | | NUMBERS ARE REQUIRED. | | | | | | 8. PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATIONS FOR WALLS AND CEILINGS. | | | | | | 9. PLEASE PROVIDE PRESCRITPIVE STRENGTH | | | REQUIREMENTS FOR ALL HANDRAILS AND | | | GUARDRAILS. | | | | | | 10. PLEASE INDICATE WHAT ITEMS WILL | | | BE STORED IN THE BUILDING. ARE ANY | | | FLAMMABLE OR COMBUSTIBLE LIQUIDS, | | | SOLIDS OR GASES PLANNED. | | | | | | 11. ANY STORAGE RACKS PLANNED. | | | | | | 12. THE FIRE ALARM SYSTEM SHALL | | | BE MONITORED BY A UL LISTED FIRE | | | ALARM COMPANY LISTED FOR CENTRAL | | | STATION SERVICE. | | | | | | 13. KNOX-BOX LOCKING CAPS SHALL BE | | | PROVIDED. | | | | | | 14. SEPARATE PLANS AND PERMITS | | | REQUIRED FOR THE FIRE SPRINKLER SYSTEM. | | | | | | 15. PROVIDE SEPARATE PLANS AND PERMITS | | | FOR FIRE ALARM SYSTEM. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
ptjomsto |
Date |
2006-04-12 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
ptjomsto |
Date |
2006-04-12 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2006-04-12 00:00:00 | REV/MECH GIVEN TO HAROLD MOSER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2006-02-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-21 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-21 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2006-02-21 00:00:00 | WAITING FOR "COMM" BD-REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2006-02-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-10 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-10 |
Time |
11:31 |
Sent To |
B |
|
| Notes |
| 2006-02-10 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-07 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-07 |
Time |
11:29 |
Sent To |
E |
|
| Notes |
| 2006-02-07 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2006-01-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-22 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-22 |
Time |
11:50 |
Sent To |
E |
|
| Notes |
| 2006-01-22 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2006-01-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-19 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-19 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2006-01-19 00:00:00 | TO "COMM" BD#37 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2005-12-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-30 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-30 |
Time |
11:47 |
Sent To |
Z |
|
| Notes |
| 2005-12-30 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2005-12-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-10 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-10 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2005-12-10 00:00:00 | WAITING FOR "COMM" BD/3 | | | REV.(BLDG,ELEC,MECH) |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-10-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-03 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-03 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2005-10-13 00:00:00 | TO "COMM" BD#45 | | 2005-10-03 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-19 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-19 |
Time |
15:55 |
Sent To |
B |
|
| Notes |
| 2005-09-19 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-09-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-15 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-15 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2005-09-15 00:00:00 | 9/15/05ROUTED TO "JWITMER" DESK FROM | | | "COMM" BD#59 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-08-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-11 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-11 |
Time |
17:16 |
Sent To |
B |
|
| Notes |
| 2005-08-11 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-10 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-10 |
Time |
17:42 |
Sent To |
B |
|
| Notes |
| 2005-08-10 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-10 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-10 |
Time |
17:07 |
Sent To |
B |
|
| Notes |
| 2005-08-10 00:00:00 | TO "JWITMER" DESK/2SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-04 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-04 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2005-08-05 00:00:00 | TO "COMM" BD#59 | | 2005-08-04 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-05 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-05 |
Time |
11:42 |
Sent To |
B |
|
| Notes |
| 2005-07-05 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-04 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-04 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2005-05-13 00:00:00 | TO "COMM" BD#11/PLANS ON RACK | | 2005-05-04 00:00:00 | IN INCOMING AWAITING SPACE ON "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-02-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-02 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-02 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2005-02-02 00:00:00 | TO COMM. BOX#59 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2006-04-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-04-13 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-04-13 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-01-23 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-01-23 |
Time |
16:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
N |
Date |
2005-12-05 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2005-12-05 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2005-12-05 |
Time |
17:20 |
Sent To |
|
|
| Notes |
| 2005-12-05 00:00:00 | NO MECHANICAL REVISIONS SUBMITTED WITH | | | THIS SET.PLEASE SEE PROVISOS FROM | | | PREVIOUS REVIEWS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-08-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-08-29 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-08-29 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2005-08-29 00:00:00 | PROVISO:2ND REQUEST | | | 1.WAREHOUSE UNITS (EXAMPLE 006) THAT | | | HAVE THE DESIGN CAPACITY OR WITH | | | AGGREGATE AIR GREATER THAN 2,000 CFM | | | SHALL HAVE FAN SHUTDOWN BY DUCT SMOKE | | | DETECTORS IN ACCORDANCE WITH 2001 FBC(M) | | | 606.2.1 & 606.2.2. | | | | | | 2.PER 2001 FBC(M)306.5, EQUIPMENT | | | LOCATED AT A HEIGHT GREATER THE 16 FT | | | ABOVE FLOOR LEVEL SHALL HAVE PERMANENT | | | MEANS OF ACCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-06-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-06-06 |
Time |
10:21 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-06-06 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2005-06-06 00:00:00 | PROVISO: | | | 1.UNIT #001 & 006 ARE REQUIRED TO HAVE | | | FAN SHUTDOWN BY DUCT SMOKE DETECTORS IN | | | ACCORDANCE WITH 2001 FBC,M 606.2.1 & | | | 606.2.2, A/C SYSTEMS THAT HAVE THE | | | DESIGN CAPACITY OR WITH AGGREGATE AIR | | | GREATER THAN 2,000 CFM SHALL HAVE FAN | | | SHUTDOWN. | | | | | | 2.PLEASE CLARIFY ACCESS TO THE AHU'S | | | LOCATED IN THE WAREHOUSE AREA AT 19 FT | | | TO THE TOP OF THE AHU. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-04 |
Time |
14:39 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-03-04 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2005-03-04 00:00:00 | DENIED: | | | REFERENCE COMMENTS FROM THE PREVIOUS | | | REVIEW: | | | COMMENT #4 - AUXILIARY DRAIN PAN WITH | | | OVERFLOW PROTECTION REQUIRED.AUXILIARY | | | DRAIN PANS ARE REQUIRED UNDER COILS | | | WHICH CONDENSATION WILL OCCUR WHERE | | | DAMAGE TO THE BUILDING OR BUILDING | | | CONTENTS CAN OCCUR (2001 FBC/M 307.2.3). | | | | | | COMMENT #5 - DUCT SMOKE DETECTORS | | | REQUIRED IN UNITS THAT HAVE THE DESIGN | | | CAPACITY GREATER THAN 2,000.PROVIDE | | | LETTER FROM THE ENGINEER AT THE | | | MANUFACTURER INDICATING THAT THE UNIT | | | WILL NOT BE ABLE TO EXCEED 2,000 CFM. | | | AC-3 IS A 5 TON UNIT AND MAY HAVE THE | | | CAPACITY TO EXCEED 2,000 CFM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-17 |
Time |
13:32 |
Rev Time |
2.30 |
| Received By |
pkrauss |
Date |
2004-12-17 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2004-12-17 00:00:00 | DENIED: | | | 1.PLAN SHEET M8.01 MECHANICAL | | | EQUIPMENT STAND DETAIL, PLEASE NOTE | | | TABLE THAT IS INDICATED & HEIGHT | | | DEMENSION IS INCORRECT.REFERENCE TABLE | | | 1511.7 OF THE 2001 FBC.TABLE INDICATES | | | HEIGHT OF THE LEGS THIS SHOULD READ | | | ABOVE THE ROOF SURFACE.THE WIDTH OF | | | EQUIPMENT LESS THAN 36" SHOULD NOT BE | | | MIN. BUT 24". | | | | | | 2.PLANS DO NOT INDICATE INSULATION ON | | | THE REFRIGERANT PIPING.SHOW COMPLIANCE | | | WITH 2001 FBC CHAPTER 13 SUB-CHAPTER | | | 611.1.ABC.1. | | | | | | 3.PLEASE NOTE EQUIPMENT LOCATED ON | | | ROOF THAT EXCEEDS 16 FT SHALL HAVE A | | | PERMENANT MEANS OF ACCESS PER 2001 | | | FBC(M)306.5. | | | | | | 4.AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED.DETAIL ON PLAN | | | SHEET M8.01 DOES NOT INDICATE AN | | | AUXILIARY PAN. | | | | | | 5.PLEASE NOTE, EQUIPMENT WITH THE | | | DESIGN CAPACITY GREATER THAN 2,000 CFM | | | SHALL BE EQUIPPED WITH DUCT SMOKE | | | DETECTORS AND HAVE NOTIFICATION TO | | | ALARM/STROBE PER 2001 FBC(M)606.2.1 & | | | 606.4.1 #2. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
N |
Date |
2005-10-15 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-10-15 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-10-15 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2005-10-15 00:00:00 | NO CHANGES TO PLUMBING ON THIS REVISIOIN |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-09-08 |
Time |
17:19 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2005-09-08 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2005-09-08 00:00:00 | REVISION APPROVED | | | | | | SHTS P3.01, P3.03, P4.01, P5.01, P5.02, | | | P6.01. CHANGED LOCATION OF TOILET ROOMS | | | AND CHANGED SANT. & WATER RISER DIAGRAMS | | | TO REFLECT CHANGES TO FLOOR PLAN. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-01 |
Time |
14:36 |
Rev Time |
2.50 |
| Received By |
kstevens |
Date |
2005-05-25 |
Time |
16:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-03-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-03 |
Time |
16:46 |
Rev Time |
6.50 |
| Received By |
kstevens |
Date |
2005-03-03 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2005-03-03 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | A) FROM PREVIOUS REVIEW: | | | 1) SHT L-3 SHOW THE LOCATION OF THE | | | CONTROLLER/TIMER, AND RAIN SENSOR. | | | SECTION 104.2.1. | | | 5) INDICATE THE SF AREA FOR EACH UNIT TO | | | CALCULATED THE MINIMUM FACILITIES PER | | | TABLES 1003.1 & 403.1. RESPONSE NOTED, | | | BUT NO SF LOCATED. | | | 6) SHT A3.03 SINK IN BREAKROOM SHALL | | | COMPLY WITH SECTION 11-4.24 AND ALL | | | SUBSECTIONS. SHOW THE FOLLOWING: | | | 11.4.24.2 HEIGHT, 11-4.24.3 KNEE | | | CLEARANCE, 11-4.24.4 SINK DEPTH, | | | 11-4.24.5 CLEAR FLOOR SPACE, FORWARD | | | APPROACH REQUIRED AND SHALL EXTEND A | | | MAXIMUM OF 19" UNDERNEATH THE SINK, | | | 11-4.24.6 EXPOSED PIPES AND SURFACES, & | | | 11-4.24.7 FAUCETS. - NO RESPONSE NOTED. | | | 9) SHT A3.09 DETAIL #8 PROVIDE | | | CALCULATIONS SHOWING COMPLIANCE WITH | | | SECTIONS 11-4.26.3(2)(3)(4). NO | | | CALCULATIONS FROM THE ENGINEER NOTED. | | | 10) SHT A3.09 SHOW COMPLIANCE WITH | | | SECTION 11-4.19.4 EXPOSED PIPES & | | | SURFACES. RESPONSE NOTED, BUT EXPOSED | | | PIPES STILL REQUIRE SHALL BE INSULATED | | | TO PREVENT INJURY. | | | 13) SHTS P5.01 & P5.02 WATER RISER | | | DIAGRAMS, SECTION 606.1(4) FULL OPEN | | | VALVES ARE REQUIRED ON EVERY WATER DOWN | | | FEED PIPE. SECTION 606.2(2) SHUT OFF | | | VALVES REQUIRED FOR HOSE BIBBS. RESPONSE | | | NOTED, BUT NO ISOMETRICS WERE FOUND ON | | | SHT P4.01. THESE VALVES SHALL BE SHOWN | | | ON ALL ISOMETRIC WATER RISER DIAGRAM. | | | **************NEW COMMENTS************ | | | 1B) SHT P5.02 SANT. RISER DIAGRAM #2/401 | | | BRANCH CONNECTION TO THE SINK FITTING IN | | | AGAINST THE FLOW. FITTINGS SHALL BE | | | INSTALLED TO GUIDE SEWAGE AND WASTE IN | | | THE DIRECTION OF FLOW. SECTION 706.3 | | | 2B) SHT A3.01 UNIT SPACE DESIGNATED 002 | | | SHOWS NO FIXTURES. PLEASE CLAIRFY. | | | SECTION 104.2.1. | | | 3B) AN RPZ BACKFLOW IS REQUIRED ON THE | | | WATER SERVICE FOR EACH BUILDING. SECTION | | | 608.13.2. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-14 |
Time |
17:32 |
Rev Time |
9.50 |
| Received By |
kstevens |
Date |
2004-12-14 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2004-12-14 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) SHT L-3 INDICATE WATER SOURCE FOR THE | | | IRRIGATION, IF SOURCE IS CITY WATER, A | | | BACKFLOW IS REQUIRED TO BE INSTALLED BY | | | A LICENCED PLUMBING CONTRACTOR. SHOW THE | | | LOCATION OF THE RPZ BACKFLOW, THE | | | CONTROLLER/TIMER, AND THE RAIN SENSOR. | | | SECTION 104.2.1. | | | 2) SHT L-3 SEE FAC 61G1-16.004 THE FIRM | | | NAME, ADDRESS AND TELEPHONE NUMBER IS | | | REQUIRED ON THE TITLE BLOCK. FS | | | 481.2055 | | | 3) SHT A0.01 INDICATE TYPE AND AMOUNT OF | | | MATERIAL TO BE STORED IN THE WAREHOUSE. | | | MORE COMMENTS MAY FOLLOW DEPENDING ON | | | THE RESPONSE. SECTION 104.2.1. | | | 4) SHT A3.01 W/C, LAV, SERVICE SINK, AND | | | DRINKING FOUNTAIN ARE REQUIRED IN EACH | | | SPACE. SEE UNIT 002. PLEASE CLAIRFY. | | | SECTOPM 104.2.1. TABLE 403.1 SECTION | | | 410.1. | | | 5) INDICATE THE SQUARE FOOTAGE AREA FOR | | | EACH UNIT TO CALCULATE THE MINIMUM | | | FACILITIES PER TABLES 1003.1 & 403.1. | | | 6) SHT A3.03 SINK IN BREAKROOM SHALL | | | COMPLY WITH SECTION 11-4.24 AND ALL | | | SUBSECTIONS. SHOW THE FOLLOWING: | | | 11-4.24.2 HEIGHT - 11-4.24.3 KNEE | | | CLEARANCE - 11-4.24.4 SINK DEPTH - | | | 11-4.24.5 CLEAR FLOOR SPACE, FORWARD | | | APPROACH REQUIRED AND SHALL EXTEND A | | | MAXIMUM OF 19" UNDERNEATH THE SINK - | | | 11-4.24.6 EXPOSED PIPES AND SURFACES - | | | 11-4.24.7 FAUCETS. | | | 7) SHT A3.05 SUBMIT CALCULATIONS FOR THE | | | PRIMARY AND SECONDARY ROOF DRAINS. SHOW | | | TOTAL SQUARE FOOTAGE AREA FOR THE ROOF | | | AND SHOW 1/2 AREA OF ALL VERTICAL WALLS | | | INCLUDING PARAPETS ADDED TO ROOF AREA. | | | SHOW THE TOTAL AREA DRAINING TO EACH | | | ROOF DRAIN. ROOF DRAINS IN EACH AREA | | | WITH OUT SECONDARY ROOF DRAINS, | | | (SCUPPERS), SHALL BE SIZED FOR PRIMARY | | | AND SECONDARY SCUPPER DRAINS TOTAL | | | AREA. | | | SECTIONS 1106 AND 1107 AND ALL | | | SUBSECTIONS. TABLES 1106.2 & 1106.3. | | | 8) INDICATE THE SIZE OF ALL DOWNSPOUTS. | | | SEE TABLE 1106.2 | | | 9) SHT A3.09 DETAIL #8 PROVIDE | | | CALCULATIONS SHOWING COMPLIANCE WITH | | | SECTIONS 11-4.26.3(2)(3)& (4). | | | 10) SHT A3.09 FOR ACCESSIBLE W/C'S SHOW | | | CLEAR FLOOR SPACE, SECTION 11-4.16.2 AND | | | FOR LAVS SHOW EXPOSED PIPES AND SURFACES | | | SECTION 11-4.19.4. | | | 11) SUBMIT A FINISH SCHEDULE SHOWING | | | REQUIREMENTS FOR PUBLIC TOILET ROOMS PER | | | SECTION 1204.2. | | | 12) SHT P4.01 DETAIL #1 MORE INFORMATION | | | REQUIRED ON THE WATER JACKET PIT. WHAT | | | IS A WATER JACKET PIT AND WHAT IS ITS | | | USE? SUBMIT MANUF. SPECIFICATIONS AND | | | INSTALLATION INSTRUCTIONS FOR REVIEW. | | | SECTION 104.2.1. | | | 13) SHTS P5.01 & P5.02 WATER RISER | | | DIAGRAMS. SECTION 606.1(4) FULL OPEN | | | VALVES ARE REQUIRED ON EVERY WATER DOWN | | | FEED PIPE. AND SECTION 606.2(2) SHUT OFF | | | VALVES REQUIRED FOR HOSE BIBBS. | | | 14) SHT P5.02 SANT. RISER #2/401 DOES | | | NOT REFLECT THE FLOOR PLAN. LAV AND SINK | | | ARE MISLABELED. SECTION 104.2.1. | | | 14) AN RPZ BACKFLOW IS REQUIRED ON THE | | | WATER SERVICE TO THE BUILDING. SECTION | | | 608.13.2. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2006-01-30 |
|
|
Cont ID |
|
| Sent By |
lshapiro |
Date |
2006-01-30 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
lshapiro |
Date |
2006-01-30 |
Time |
08:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
lshapiro |
Date |
2006-01-20 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
lshapiro |
Date |
2006-01-20 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2006-01-20 00:00:00 | THE PLANNING & ZONING DEPARTMENT WILL | | | NEED A REVISED SITE AND LANDSCAPE PLANS | | | PRIOR TO BUILDING PERMIT APPROVAL. | | | | | | THE FOLLOWING INFORMATION IS NEEDED: | | | 1. PROVIDE A SITE PLAN AND LANDSCAPE | | | PLAN MATCHING THE BUILDING PLANS | | | (INCLUDING BUILDINGS 1-3); | | | 1.A. THE REVISIONS SHALL REFLECT CHANGES | | | IN THE LOCATION OF PARKING, THE LOCATION | | | OF THE ELECTRICAL EQUIPMENT ROOM, AND | | | DRIVEWAY.ALSO, PROVIDE THE REVISED | | | PARKING CALCULATIONS ON THE SITE PLAN | | | INCLUDING TOTAL PROVIDED AND REQUIRED. | | | 1.B. THE NEW SITE PLAN WILL NEED TO BE | | | REVIEWED BY THE PUBLIC UTILITIES | | | DEPARTMENT AS THEY REVIEW CURBCUTS AND | | | DRIVEWAY LOCATIONS. | | | 1.C. SHOW HOW THE LOCATION OF THE | | | ELECTRICAL EQUIPMENT ROOM STRUCTURE | | | AFFECTS THE PERPENDICULAR DRIVE FROM | | | BUILDING 1.THE LOCATION OF THE | | | EQUIPMENT ROOM SHALL NOT AFFECT THE | | | TRAFFIC FLOW ON THE DRIVEWAY. | | | 1.D. A LANDSCAPE ISLAND SHALL BE | | | MAINTAINED AT THE CURBCUT OF THE DRIVE | | | NEXT TO THE ELECTRICAL EQUIPMENT ROOM. | | | 2. PROVIDE THE DIMENSIONS OF THE | | | ELECTRICAL EQUIPMENT ROOM. | | | 3. THE LOCATION OF THE EQUIPMENT ROOM | | | DOES NOT MATCH BETWEEN THE PHOTOMETRICS | | | PLAN AND THE BUILDING PLAN.PLEASE | | | REVISE. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-01 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-01 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2005-03-01 00:00:00 | JOSH LONG, SENIOR PLANNER 822-1449 | | | APPROVED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-12-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-12-15 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-12-15 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2004-12-16 00:00:00 | DENIED, | | | 1. PHASE 1 MUST HAVE HANDICAP | | | ACCESSIBILITY FROM HAVERHILL'S SIDEWALK, | | | MUST INCLUDE A SIDEWALK FROM HAVERHILL'S | | | SIDEWALK TO THEIR PROPERTY. | | | 2. THE NEW RECORDED PLAT MUST BE | | | INCLUDED WITH RESUBMITTAL. | | | 3. LANDSCAPE SITE PLAN DOES NOT SHOW | | | ENTRANCE FROM HAVERHILL | | | ANY QUESTIONS, PLEASE CALL JOSH LONG, | | | PLANNER AT 822-1435 |
|
|