Plan Review Details - Permit 04110925
Plan Review Stops For Permit 04110925
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-02-15 Cont ID  
Sent By lsmith Date 2005-02-15 Time 07:39 Rev Time 0.50
Received By lsmith Date 2005-02-15 Time 07:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-12-03 Cont ID  
Sent By lsmith Date 2004-12-03 Time 10:10 Rev Time 0.75
Received By lsmith Date 2004-12-03 Time 10:10 Sent To  
Notes
2004-12-03 00:00:00BUILDING PLAN REVIEW: FAILED
  
 1. SHOW METHOD OF COMPLIANCE WITH THE
 FLORIDA POOL SAFETY ACT ON PLANS PER FBC
 424.2.17.1.9.
  
 ANY QUESTIONS PLEASE CALL;
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-01-31 Cont ID  
Sent By dpalmer Date 2005-01-31 Time 16:29 Rev Time 0.25
Received By dpalmer Date 2005-01-31 Time 16:29 Sent To P
Notes
2005-01-31 00:00:00OCP STILL NOT SHOWN FOR NEW PANEL.
  
 INSPEC T TO VERIFY, PLANS REDLINED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-11-23 Cont ID  
Sent By mjacobs Date 2004-11-22 Time 12:41 Rev Time 0.25
Received By dpalmer Date 2004-11-23 Time 05:56 Sent To P
Notes
2004-11-23 00:00:00****** UNSAT ********
  
 1)NOTE: PLEASE SEE PLANS INDICATE A NEW
 SUB-PANEL INSTALLED. PLEASE PROVIDE SIZE
 OF PANEL, SIZE OF OCP FEEDING NEW PANEL
 ALONG WITH CONDUIT, CONDUCTORS ETC.
 215.5,240.4,310.16, 250
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-01-28 Cont ID  
Sent By mjacobs Date 2005-01-28 Time 12:11 Rev Time 0.00
Received By mjacobs Date 2005-01-28 Time 12:11 Sent To E
Notes
2005-01-28 00:00:00TO 'DP" DESK/RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-11-22 Cont ID  
Sent By mjacobs Date 2004-11-22 Time 12:40 Rev Time 0.00
Received By mjacobs Date 2004-11-22 Time 12:40 Sent To E
Notes
2004-11-22 00:00:00SENT TO "E" BOX/POOL.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-11-17 Cont ID  
Sent By csiegber Date 2004-11-17 Time 16:11 Rev Time 0.00
Received By csiegber Date 2004-11-17 Time 15:54 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-02-14 Cont ID  
Sent By kstevens Date 2005-02-14 Time 16:20 Rev Time 0.55
Received By kstevens Date 2005-02-14 Time 16:20 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-12-01 Cont ID  
Sent By kstevens Date 2004-12-01 Time 18:05 Rev Time 0.60
Received By kstevens Date 2004-12-01 Time 18:05 Sent To B1
Notes
2004-12-01 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING
 POOLS
  
  
 1) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 2) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE WATER HEATER WHEN PUMP IS
 SHUT OFF. (MANUF CUT SHEETS SUBMITTAL)
 3)SEPARATE PLANS AND PERMIT REQUIRED FOR
 THE GAS INSTALLATION. (ADD TO NOTES)
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-11-19 Cont ID  
Sent By mmclean Date 2004-11-19 Time 15:56 Rev Time 0.00
Received By mmclean Date 2004-11-19 Time 15:56 Sent To I
Notes
***NONE***