| Plan Review Stops For Permit 04110666 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-01-14 |
Time |
15:50 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2005-01-14 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2005-01-14 00:00:00 | DENIED | | | | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 4.ADDITIONAL PERMIT FEES OF | | | $60.59 ARE DUR PRIOR TO ISSUING OF | | | PERMIT.SEE PREVIOUS REVEW FOR BREAK | | | DOWN. | | | | | | ANY QUESTIONS CALL ME | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-12-08 |
Time |
10:37 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2004-12-08 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2004-12-08 00:00:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.SHOW WINDOW OVER TUB AREA TO BE | | | SAFTEY GLAZING PER FBC 2405.2.1 | | | | | | 4.BASED ON SBCCI BUILDING VALUATION | | | DATA THE PROJECT VALUE HAS BEEN CHANGED | | | TO $56,257ADDTIONAL PERMIT FEES ARE | | | DUE PRIOR TO ISSUING OF PERMIT. | | | | | | 5.SHOW ATTIC ACCESS SIZE AND LOCATION | | | COMPLYING WITH FBC 2309.6 | | | | | | 6.SHOW HOW EXISTING BUILDING WILL | | | COMPLY WITH SMOKE DETECTORS AND GFCI | | | OUTLETS.FBC 3401.7.1.2.1 | | | | | | ANY QUESTIONS CALL ME | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-05 |
Time |
13:35 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-01-05 |
Time |
13:35 |
Sent To |
P |
|
| Notes |
| 2005-01-05 00:00:00 | | | | *** PERMIT APPLICATION DID NOT COME BACK | | | WITH RESUB. CALLED OWNER,LEFT MESSAGE. | | | | | | REDLINED PLANS, 22,000 AIC RATED MAIN | | | MIN. | | | | | | REDLINE SD'S IN EXISTING BED RMS PER | | | NFPA-72 8-1.4.1.6.2 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-11-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-22 |
Time |
15:56 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-11-22 |
Time |
15:56 |
Sent To |
P |
|
| Notes |
| 2004-11-22 00:00:00 | ******* UNSAT ******** | | | | | | 1)NOTE: PLEASE SEE PLANS REFERENCE PALM | | | BEACH COUNTY. PLEAS SEE JOBSITE IS IN | | | THE CITY OF WEST PALM BEACH. | | | | | | 2)NOTE: PLEASE SEE 210.52D,210.11C3 FOR | | | MIN REQUIRED BATH GFI. MUST BE 20A AND | | | 312 AWG. | | | | | | 3)NOTE: PLEASE SEE 424.3B FOR SIZING OF | | | OCP FOR AHU HEAT. | | | | | | 4)NOTE: PLEASE SEE FBC CHAPTER 34 FOR | | | ADDITIONS TO EXISTING DWELLINGS. | | | PLEASE PROVIDE LAYOUT OF EXISTING SD' | | | AND GFI EITHER EXISTING OR NEW TO MEET | | | 2002 NEC, NFPA-72 8-1.4.1.6.2 | | | *** THIS IS ONLY A NOTE*** | | | PLANS SHOW THREE SD'S IN MASTER BEDRM?? | | | PLEASE ALSO SEE SD'S IN LOCATIONS NOT | | | REQUIRED. ? | | | THIS IS NOT A CODE VIOLATION, ONLY NOTED | | | FOR AMOUNT ABOVE REQUIRED? | | | | | | 5)NOTE: PLEASE SEE FBC 104.2.1. | | | PLEASE HAVE PERSON RESPONSIBLE FOR | | | PLANS, SIGN WITH OUT RUBBER STAMP. | | | | | | 6)NOTE: PLEASE SEE A/C DISCONNECT IS | | | NOTED AS BEING 50A WHEN REQUIRED TO BE | | | 60A MIN.? | | | 424.3.B | | | | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER | | | REVIEWERS WHICH MAY AFFECT ELECTRICAL | | | PLANS.? | | | | | | PLEASE REMOVE ALL OLD VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD SHOULD BE SUBMITTED FOR | | | REFERENCE ONLY. | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-05 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-05 |
Time |
08:52 |
Sent To |
E |
|
| Notes |
| 2005-01-05 00:00:00 | TO "DP" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-29 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-29 |
Time |
13:27 |
Sent To |
Z |
|
| Notes |
| 2004-12-29 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-12 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-12 |
Time |
16:28 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-14 |
Time |
11:24 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-14 |
Time |
11:23 |
Sent To |
B |
|
| Notes |
| 2005-01-14 00:00:00 | 1. EQUIPMENT REFLECTED ON PLAN SHOWS | | | 10 SEER RATED A/C EQUIPMENT BUT ENERGY | | | CAULKS REFLECT MIN. OF 12 SEER. | | | 2. A/C EQUIPMENT CONDENSATE MUST | | | CONFORM WITH 2001 FBC/M SECTION 307 AND | | | 307.2.3. | | | PAT RAFTER 561/805/6725 OR 8056719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-06 |
Time |
08:49 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-12-06 |
Time |
08:33 |
Sent To |
B |
|
| Notes |
| 2004-12-06 00:00:00 | DENIED: | | | 1.PROVIDE EQUIPMENT SCHEDULE. | | | 2.INDICATE IF THE EQUIPMENT IS NEW OR | | | EXISTING.PLEASE NOTE, THE ENERGY | | | CALCULATIONS INDICATE A 1 TON SYSTEM FOR | | | THE ADDITION.IT APPEARS THE EXISTING | | | SYSTEM IS ALSO SERVING THE ADDITION AS | | | WELL AS THE EXISTING LIVING AREA. | | | 3.PLAN SHEET A-1 DOES NOT INDICATE | | | SIZE OF THE DUCT BACK TO THE EXISTING | | | DUCT SYSTEM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-06 |
Time |
15:06 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-01-06 |
Time |
15:06 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-11-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-27 |
Time |
07:17 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-11-27 |
Time |
07:17 |
Sent To |
M |
|
| Notes |
| 2004-11-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | | | | 1) SHT A-3 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE REQUIREMENTS. ONLY THE | | | FIXTURES WITHIN THE BATHROOMGROUP SHALL | | | CONNECT TO THE WET-VENTED HORIZONTAL | | | BRANCH DRAIN. ANY ADDITIONAL FIXTURES | | | SHALL DISCHARGE DOWNSTREAM OF THE WET | | | VENT. SECTION 909.1. (THE KITCHEN SINK | | | SHALL CONNECT DOWNSTREAM OF THE BATHROOM | | | FIXTURES) - SEE RED LINE CORRECTIONS FOR | | | AN EXAMPLE OF HOW THE RISER WILL MEET | | | CODE REQUIREMENTS. | | | 2) ALL DRAWINGS SHALL BEAR THE NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR | | | THE DESIGN. SECTION 104.2.1 - STAMPED | | | SIGNATURES ARE NOT APPROVED. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-04 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-04 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-04 |
Time |
14:59 |
Sent To |
I |
|
| Notes |
|
|