| Plan Review Stops For Permit 04110639 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-02-08 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-02-08 |
Time |
09:42 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2005-02-08 |
Time |
09:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-29 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-11-29 |
Time |
12:49 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2004-11-29 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2004-11-29 00:00:00 | BUILDING PLAN REVIEW FAILED: | | | | | | 1. CHILD BARRIER FENCE NOT SHOWN ON | | | PLANS. | | | | | | 2. POOL EQUIPMENT ANCHORING DETAIL NEEDS | | | TO BE INCLUDED ON PLANS. | | | | | | 3. PLANS SHOW A FOOTER FOR A FUTURE | | | SCREEN ENCLOSURE. | | | | | | 4. SCREEN ENCLOSURE MUST BE APPLIED FOR | | | SEPARATELY WITH ENGINEERED PLANS. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILIDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-01-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-13 |
Time |
11:35 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-01-13 |
Time |
11:35 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-23 |
Time |
06:01 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-11-23 |
Time |
06:01 |
Sent To |
P |
|
| Notes |
| 2004-11-23 00:00:00 | ******* UNSAT ******* | | | | | | 1)NOTE: PLEASE SUBMIT COMPLETE LOAD | | | CALCULATIONS SHOWING ALL EXISTING AND | | | NEW LOADS. 220.31B | | | PLEASE BE SURE ALL LARGEST MOTORS AND | | | CONTINUOUS LOADS ARE SHOWN AT | | | 125%.(HEAT-PUMP) | | | 215.3,230.42 ETC | | | | | | 2)NOTE: PLEASE INDICATE FEED FOR NEW | | | PANEL SHWON ON DIAGRAM. PLEASE SHOW OCP | | | FOR FEED, CONDUIT, CONDUCTOR SIZES ETC. | | | | | | 3)NOTE: PLEASE SEE FBC 104.2.1 FOR ALL | | | PLANS/DEATILS SUBMITTED. | | | | | | PLEASE ALSO SEE FS 471.025, FOR PLANS | | | WHICH CONTAIN A TITLE BLOCK FROM AN | | | ENGINEER, MUST ALSO BE SIGNED,DATED AND | | | SEALED. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-01-28 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-28 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-28 |
Time |
14:30 |
Sent To |
P |
|
| Notes |
| 2005-01-28 00:00:00 | TO "P" BOX/RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-10 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-10 |
Time |
12:15 |
Sent To |
E |
|
| Notes |
| 2005-01-10 00:00:00 | TO "DP" DESK/RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-11-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-17 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-17 |
Time |
12:20 |
Sent To |
E |
|
| Notes |
| 2004-11-17 00:00:00 | SENT TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-12 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-12 |
Time |
11:39 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-02-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-02-03 |
Time |
16:38 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2005-02-03 |
Time |
16:38 |
Sent To |
B1 |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-01-21 |
Time |
07:47 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2005-01-21 |
Time |
07:47 |
Sent To |
B |
|
| Notes |
| 2005-01-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 424.2 SWIMMING | | | POOLS | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) COMMENT RESPONSE FOR ITEMS 1 THRU 6 | | | SHALL BE SIGNED & SEALED BY THE ENGINEER | | | OF RECORD. TITLE BLOCK WITH ALL REQUIRED | | | INFORMATION IS REQUIRED ON THE SIGNED, | | | SEALED, AND DATED SHEET. | | | 61G15-23.002(1)(2) & FS 471.025 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-11-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-27 |
Time |
06:35 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-11-27 |
Time |
06:35 |
Sent To |
B1 |
|
| Notes |
| 2004-11-27 00:00:00 | DENIED | | | REFERENCE; FBC-2001 424.2 SWIMMING | | | POOLS | | | | | | A) THE FOLLOWING INFORMATION REQUIRED | | | ON | | | THE PLANS FOR POOL PERMIT. PLEASE | | | SUBMIT | | | A DETAIL, MANUF SPECIFICATION SHEETS, | | | OR | | | ADD INFORMATION TO NOTES OF PLANS AS | | | REQUIRED. | | | 1) COMPLY WITH FBC-2001 SEC 424.2 | | | PRIVATE SWIMMING POOLS. (ADD TO NOTES) | | | 2) FBC-2001 SEC 424.2.6.1 ENGINEERING | | | DESIGN, CONSTRUCTION AND WORKMANSHIP. | | | ANSI/NSPI-5. (ADD TO NOTES) | | | 3) FBC-2001 424.2.7.2 PUMPS AND | | | EQUIPMENT SHALL BE MOUNTED ON A | | | SUBSTANTIAL BASE IN A MANNER THAT WILL | | | ELIMINATE STRAIN ON PIPING.SLAB SHALL | | | BE A NOMINAL 4" THICK. (DETAIL) | | | 4) FBC-2001 424.2.9 WATER SUPPLY, LOCAL | | | ORD. #2938-95, BACKFLOW REQUIRED ON THE | | | WATER SERVICE. (ADD TO NOTES) | | | 5) FBC-2001 424.2.12.1 PRESSURE TESTS. | | | PER MANUFACTURE RECOMMENDATIONS, NO AIR | | | TEST SHALL BE APPROVED FOR PVC PIPE AND | | | FITTINGS. (ADD TO NOTES) | | | 6) FBC-2001 424.2.13.2 JOINTS AND | | | CONNECTIONS, FBC PLMG SEC 605.21, PURPLE | | | PRIMER REQUIRED ON PVC PIPING AND | | | FITTINGS. (ADD TO NOTES) | | | 7) FBC-2001 424.2.14.2 WATER RETENTION, | | | PROVIDE A POSITIVE MEANS OF RETAINING | | | WATER IN THE HEATER WHEN PUMP IS SHUT | | | OFF. AQUACAL HEAT PUMP DOES NOT SHOW | | | THIS REQUIREMENT INTERNALLY, SO AN | | | EXTERNAL HARTFORD LOOP WILL BE REQUIRED. | | | INDICATE THIS ON THE POOL EQUIPMENT | | | DIAGRAM SHEET 2 OF 4. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-11-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-11-17 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-11-17 |
Time |
09:20 |
Sent To |
I |
|
| Notes |
| 2004-11-17 00:00:00 | NOTE: PROPERTY IS BACKED UP TO A | | | MAN-MADE LAKE AND THEN A GOLF COURSE. | | | MEET THE SETBACK OF 3FT IN REAR FOR | | | POOL. |
|
|