Plan Review Details - Permit 04110639
Plan Review Stops For Permit 04110639
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-02-08 Cont ID  
Sent By lsmith Date 2005-02-08 Time 09:42 Rev Time 0.50
Received By lsmith Date 2005-02-08 Time 09:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-11-29 Cont ID  
Sent By lsmith Date 2004-11-29 Time 12:49 Rev Time 0.75
Received By lsmith Date 2004-11-29 Time 12:49 Sent To  
Notes
2004-11-29 00:00:00BUILDING PLAN REVIEW FAILED:
  
 1. CHILD BARRIER FENCE NOT SHOWN ON
 PLANS.
  
 2. POOL EQUIPMENT ANCHORING DETAIL NEEDS
 TO BE INCLUDED ON PLANS.
  
 3. PLANS SHOW A FOOTER FOR A FUTURE
 SCREEN ENCLOSURE.
  
 4. SCREEN ENCLOSURE MUST BE APPLIED FOR
 SEPARATELY WITH ENGINEERED PLANS.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILIDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-01-13 Cont ID  
Sent By dpalmer Date 2005-01-13 Time 11:35 Rev Time 0.25
Received By dpalmer Date 2005-01-13 Time 11:35 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-11-23 Cont ID  
Sent By dpalmer Date 2004-11-23 Time 06:01 Rev Time 0.25
Received By dpalmer Date 2004-11-23 Time 06:01 Sent To P
Notes
2004-11-23 00:00:00******* UNSAT *******
  
 1)NOTE: PLEASE SUBMIT COMPLETE LOAD
 CALCULATIONS SHOWING ALL EXISTING AND
 NEW LOADS. 220.31B
 PLEASE BE SURE ALL LARGEST MOTORS AND
 CONTINUOUS LOADS ARE SHOWN AT
 125%.(HEAT-PUMP)
 215.3,230.42 ETC
  
 2)NOTE: PLEASE INDICATE FEED FOR NEW
 PANEL SHWON ON DIAGRAM. PLEASE SHOW OCP
 FOR FEED, CONDUIT, CONDUCTOR SIZES ETC.
  
 3)NOTE: PLEASE SEE FBC 104.2.1 FOR ALL
 PLANS/DEATILS SUBMITTED.
  
 PLEASE ALSO SEE FS 471.025, FOR PLANS
 WHICH CONTAIN A TITLE BLOCK FROM AN
 ENGINEER, MUST ALSO BE SIGNED,DATED AND
 SEALED.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-01-28 Cont ID  
Sent By mjacobs Date 2005-01-28 Time 14:30 Rev Time 0.00
Received By mjacobs Date 2005-01-28 Time 14:30 Sent To P
Notes
2005-01-28 00:00:00TO "P" BOX/RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-01-10 Cont ID  
Sent By mjacobs Date 2005-01-10 Time 12:15 Rev Time 0.00
Received By mjacobs Date 2005-01-10 Time 12:15 Sent To E
Notes
2005-01-10 00:00:00TO "DP" DESK/RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-11-17 Cont ID  
Sent By mjacobs Date 2004-11-17 Time 12:20 Rev Time 0.00
Received By mjacobs Date 2004-11-17 Time 12:20 Sent To E
Notes
2004-11-17 00:00:00SENT TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-11-12 Cont ID  
Sent By csiegber Date 2004-11-12 Time 11:39 Rev Time 0.00
Received By csiegber Date 2004-11-12 Time 11:39 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-02-03 Cont ID  
Sent By kstevens Date 2005-02-03 Time 16:38 Rev Time 0.33
Received By kstevens Date 2005-02-03 Time 16:38 Sent To B1
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-01-21 Cont ID  
Sent By kstevens Date 2005-01-21 Time 07:47 Rev Time 0.33
Received By kstevens Date 2005-01-21 Time 07:47 Sent To B
Notes
2005-01-21 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING
 POOLS
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) COMMENT RESPONSE FOR ITEMS 1 THRU 6
 SHALL BE SIGNED & SEALED BY THE ENGINEER
 OF RECORD. TITLE BLOCK WITH ALL REQUIRED
 INFORMATION IS REQUIRED ON THE SIGNED,
 SEALED, AND DATED SHEET.
 61G15-23.002(1)(2) & FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-11-27 Cont ID  
Sent By kstevens Date 2004-11-27 Time 06:35 Rev Time 0.50
Received By kstevens Date 2004-11-27 Time 06:35 Sent To B1
Notes
2004-11-27 00:00:00DENIED
 REFERENCE; FBC-2001 424.2 SWIMMING
 POOLS
  
 A) THE FOLLOWING INFORMATION REQUIRED
 ON
 THE PLANS FOR POOL PERMIT. PLEASE
 SUBMIT
 A DETAIL, MANUF SPECIFICATION SHEETS,
 OR
 ADD INFORMATION TO NOTES OF PLANS AS
 REQUIRED.
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS. (ADD TO NOTES)
 2) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5. (ADD TO NOTES)
 3) FBC-2001 424.2.7.2 PUMPS AND
 EQUIPMENT SHALL BE MOUNTED ON A
 SUBSTANTIAL BASE IN A MANNER THAT WILL
 ELIMINATE STRAIN ON PIPING.SLAB SHALL
 BE A NOMINAL 4" THICK. (DETAIL)
 4) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2938-95, BACKFLOW REQUIRED ON THE
 WATER SERVICE. (ADD TO NOTES)
 5) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 6) FBC-2001 424.2.13.2 JOINTS AND
 CONNECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING AND
 FITTINGS. (ADD TO NOTES)
 7) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. AQUACAL HEAT PUMP DOES NOT SHOW
 THIS REQUIREMENT INTERNALLY, SO AN
 EXTERNAL HARTFORD LOOP WILL BE REQUIRED.
 INDICATE THIS ON THE POOL EQUIPMENT
 DIAGRAM SHEET 2 OF 4.
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-11-17 Cont ID  
Sent By mmclean Date 2004-11-17 Time 09:20 Rev Time 0.00
Received By mmclean Date 2004-11-17 Time 09:20 Sent To I
Notes
2004-11-17 00:00:00NOTE: PROPERTY IS BACKED UP TO A
 MAN-MADE LAKE AND THEN A GOLF COURSE.
 MEET THE SETBACK OF 3FT IN REAR FOR
 POOL.