Plan Review Details - Permit 04110638
Plan Review Stops For Permit 04110638
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-02-08 Cont ID  
Sent By lsmith Date 2005-02-08 Time 09:49 Rev Time 0.50
Received By lsmith Date 2005-02-08 Time 09:49 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-11-29 Cont ID  
Sent By lsmith Date 2004-11-29 Time 12:13 Rev Time 0.75
Received By lsmith Date 2004-11-29 Time 12:13 Sent To  
Notes
2004-11-29 00:00:00BUILDING PLAN REVIEW FAILED
  
 1. SHOW DETAIL FOR ANCHORING POOL
 EQUIPMENT ON PLAN PER FBC 2001 SEC
 424.2.7.2.
  
 2. FOOTER DETAIL SHOWN ON PLANS.
  
 3. SCREEN ENCLOSURE MUST BE BY SEPARATE
 PERMIT WITH ENGINEERED DRAWINGS.
  
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-01-13 Cont ID  
Sent By dpalmer Date 2005-01-13 Time 11:17 Rev Time 0.25
Received By dpalmer Date 2005-01-13 Time 11:17 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-11-23 Cont ID  
Sent By dpalmer Date 2004-11-23 Time 06:15 Rev Time 0.25
Received By dpalmer Date 2004-11-23 Time 06:13 Sent To P
Notes
2004-11-23 00:00:00******* UNSAT *******
  
 1)NOTE: PLEASE SEE PLANS INDICATE A NEW
 PANEL YET NO INFORMATION FOR FEED TO NEW
 PANEL.
 PLEASE SHOW SIZE OF NEW PANEL.
 PLEASE SHOW SIZE OF FEED, OCP, CONDUITM
 CONDUCTORS ETC.
 215.5,240.4,310.16,250
  
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-01-28 Cont ID  
Sent By mjacobs Date 2005-01-28 Time 14:27 Rev Time 0.00
Received By mjacobs Date 2005-01-28 Time 14:27 Sent To P
Notes
2005-01-28 00:00:00TO "P" BOX/RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-10 Cont ID  
Sent By mjacobs Date 2005-01-10 Time 12:01 Rev Time 0.00
Received By mjacobs Date 2005-01-10 Time 12:01 Sent To E
Notes
2005-01-10 00:00:00TO "DP" DESK./RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-11-12 Cont ID  
Sent By csiegber Date 2004-11-12 Time 11:38 Rev Time 0.00
Received By csiegber Date 2004-11-12 Time 11:38 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-02-08 Cont ID  
Sent By kstevens Date 2005-02-08 Time 10:32 Rev Time 0.75
Received By kstevens Date 2005-02-08 Time 10:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-01-21 Cont ID  
Sent By kstevens Date 2005-01-21 Time 08:40 Rev Time 0.33
Received By kstevens Date 2005-01-21 Time 08:40 Sent To B1
Notes
2005-01-21 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING
 POOLS
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) COMMENT RESPONSE FOR ITEMS 1 THRU 6
 SHALL BE SIGNED & SEALED BY THE
 ENGINEER
 OF RECORD. TITLE BLOCK WITH ALL
 REQUIRED
 INFORMATION IS REQUIRED ON THE SIGNED,
 SEALED, AND DATED SHEET.
 61G15-23.002(1)(2) & FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-11-27 Cont ID  
Sent By kstevens Date 2004-11-27 Time 06:57 Rev Time 0.33
Received By kstevens Date 2004-11-27 Time 06:57 Sent To B1
Notes
2004-11-27 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING
 POOLS
  
  
 A) THE FOLLOWING INFORMATION IS REQUIRED
 ON THE PLANS FOR POOL PERMIT. PLEASE
 SUBMIT A DETAIL, MANUF. SPECIFICATIONS
 OR ADD INFORMATION TO NOTES AS
 REQUIRED.
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS.
 2) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5. (ADD TO NOTES)
 3) FBC-2001 424.2.7.2 PUMPS AND
 EQUIPMENT SHALL BE MOUNTED ON A
 SUBSTANTIAL BASE IN A MANNER THAT WILL
 ELIMINATE STRAIN ON PIPING.SLAB SHALL
 BE A NOMINAL 4" THICK. (DETAIL)
 4) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD #2938-95, BACKFLOW REQUIRED ON THE
 WATER SERVICE. (ADD TO NOTES)
 5) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 6) FBC-2001 424.2.13.2 JOINTS AND
 CONNECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING AND
 FITTINGS. (ADD TO NOTES)
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-11-16 Cont ID  
Sent By mmclean Date 2004-11-16 Time 16:29 Rev Time 0.00
Received By mmclean Date 2004-11-16 Time 16:29 Sent To I
Notes
***NONE***