Plan Review Details - Permit 04110562
Plan Review Stops For Permit 04110562
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-12-15 Cont ID  
Sent By alange Date 2004-12-15 Time 14:00 Rev Time 0.50
Received By alange Date 2004-12-15 Time 14:00 Sent To P
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-12-08 Cont ID  
Sent By alange Date 2004-12-08 Time 15:52 Rev Time 1.25
Received By alange Date 2004-12-08 Time 14:24 Sent To  
Notes
2004-12-08 00:00:00DENIED
  
  
 1.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2.WATER STOP REQUIRED WHERE EXTERIOR
 WALL MASONARY UNITS BEAR ON A CONCRETE
 FLOOR SURFACE.SHOW ON PLAN AN 1 1/2"
 WATER STOP.FBC 2111.1.9 WPB
 AMMENDMENTS.
  
 3.SHOW SAFTEY GAZING AT TUB WINDOW
 LOCATION.FBC 2405.2.1
  
 4.ON EXISTING BEDROOM SHOWN ON PLAN
 SHOW SIZE AND TYPE OF EGRESS WINDOW AND
 INCLUDE SILL HEIGHT.FBC1005.4
  
 5.POVIDE A NAME AND SIGNATURE ON
 DRAWING OF THE PERSON RESPONSIBLE FOR
 THE DRAWINGS.FBC 104.2.1
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-11-18 Cont ID  
Sent By btrobaug Date 2004-11-18 Time 18:59 Rev Time 0.00
Received By btrobaug Date 2004-11-18 Time 18:44 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-12-13 Cont ID  
Sent By mjacobs Date 2004-12-13 Time 07:58 Rev Time 0.00
Received By mjacobs Date 2004-12-13 Time 07:58 Sent To B
Notes
2004-12-13 00:00:00SENT TO "AL" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-11-17 Cont ID  
Sent By mjacobs Date 2004-11-17 Time 12:36 Rev Time 0.00
Received By mjacobs Date 2004-11-17 Time 12:36 Sent To E
Notes
2004-11-17 00:00:00SENT TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-11-10 Cont ID  
Sent By csiegber Date 2004-11-10 Time 13:38 Rev Time 0.00
Received By csiegber Date 2004-11-10 Time 13:38 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-12-08 Cont ID  
Sent By pkrauss Date 2004-12-08 Time 11:22 Rev Time 0.30
Received By pkrauss Date 2004-12-08 Time 07:39 Sent To B
Notes
2004-12-08 00:00:00NO A/C WORK INDICATED ONLY BATHROOM
 EXHAUST FOR THE BATHROOM.
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-12-20 Cont ID  
Sent By kstevens Date 2004-12-20 Time 16:26 Rev Time 0.50
Received By kstevens Date 2004-12-20 Time 16:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-11-27 Cont ID  
Sent By kstevens Date 2004-11-27 Time 05:50 Rev Time 0.25
Received By kstevens Date 2004-11-27 Time 05:49 Sent To M
Notes
2004-11-27 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
  
 1) PLUMBING OK BUT ALL DRAWINGS SHALL
 BEAR THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN.
 SECTION 104.2.1
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-11-17 Cont ID  
Sent By mmclean Date 2004-11-17 Time 09:59 Rev Time 0.00
Received By mmclean Date 2004-11-17 Time 09:59 Sent To I
Notes
***NONE***