Plan Review Details - Permit 04110543
Plan Review Stops For Permit 04110543
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-02-15 Cont ID  
Sent By rbrown Date 2005-02-15 Time 16:35 Rev Time 0.00
Received By rbrown Date 2005-02-15 Time 16:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-02-11 Cont ID  
Sent By rbrown Date 2005-02-11 Time 10:50 Rev Time 0.00
Received By rbrown Date 2005-02-11 Time 10:31 Sent To  
Notes
2005-02-11 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
 F.S.= FLORIDA (STATE) STATUTE
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 1/12/05:
  
 1) 713.13 F.S.A COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED.
  
 2) 481.219 F.S.CERTIFICATE OF
 AUTHORIZATION.THE GN, A AND E SHEETS
 STILL STATE THAT THE PLANS ARE "..THE
 PROPERTY OF YOSHINO TRIESCHMANN DESIGN
 GROUP..." IN THE COPYRIGHT STATEMENT.
 THE TITLE BLOCK FOR ANY SHEET BEARING
 THE NAME OF AN ARCHITECT PRACTICING
 UNDER A FICTITIOUS NAME, A CORPORATION,
 OR A PARTNERSHIP, OFFERING
 ARCHITECTURAL
 SERVICES, SHALL INCLUDE THE CERTIFICATE
 OF AUTHORIZATION NUMBER.REMOVE THE
 YOSHINO TRIESCHMANN DESIGN GROUP
 COMPANY
 NAME FROM THE PLANS.
  
 3) TO EXPEDITE REVIEW OF A RESUBMITTAL
 WHICH REQUIRES NEW PLANS IN ORDER TO
 ADDRESS THE ABOVE COMMENTS, THE OLD
 SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHOULD BE STAPLED/CLIPPED TO THE
 REMAINING OLD SHEETS, TO FORM A SET OF
 'OLD/VOID SHEETS', FOR COMPARISON OF
 REVISIONS WHEN REVIEWING THE
 RESUBMITTED
 PLANS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
  
 THE CODE REFERENCES GIVE ADDITIONAL
 INFO
  
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-01-12 Cont ID  
Sent By rbrown Date 2005-01-12 Time 16:27 Rev Time 0.00
Received By rbrown Date 2005-01-12 Time 16:27 Sent To  
Notes
2005-01-12 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
 F.S.= FLORIDA (STATE) STATUTE
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 12/9/04:
  
 1) 713.13 F.S.A NOTICE OF
 COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST
 BE RE-RECORDED IF THE DESCRIBED
 IMPROVEMENT OR CONSTRUCTION IS NOT
 COMMENCED WITHIN 90 DAYS OF RECORDING.
  
 2) 481.219 F.S.CERTIFICATE OF
 AUTHORIZATION.IT IS NOTED THAT A
 NUMBER (P94000038344) HAS BEEN ADDED TO
 THE TITLE BLOC ON EACH SHEET.THAT
 NUMBER IS NOT LISTEDAS A CERTIFICATE
 OF AUTHORIZATION NUMBER ON THE DBPR
 LICENSE SEARCH WEBSITE.THAT WEBSITE
 SHOWS THE STATUS AS 'APPLICATION IN
 PROGRESS'.THE TITLE BLOCK FOR ANY
 SHEET BEARING THE NAME OF AN ARCHITECT
 PRACTICING UNDER A FICTITIOUS NAME, A
 CORPORATION, OR A PARTNERSHIP, OFFERING
 ARCHITECTURAL SERVICES, SHALL INCLUDE
 THE CERTIFICATE OF AUTHORIZATION
 NUMBER.IF A PERMIT IS TO BE ISSUED
 BEFORE THIS NUMBER BECOMES AVAILABLE,
 THE COMPANY NAME MUST BE OMITTED FROM
 THE PLANS, LEAVING THE ADDRESS AS IT IS
 APPLICABLE TO DONALD YOSHINO'S
 ARCHITECT'S LICENSE.
  
 3) TO EXPEDITE REVIEW OF A RESUBMITTAL
 WHICH REQUIRES NEW PLANS IN ORDER TO
 ADDRESS THE ABOVE COMMENTS, THE OLD
 SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHOULD BE STAPLED/CLIPPED TO THE
 REMAINING OLD SHEETS, TO FORM A SET OF
 'OLD/VOID SHEETS', FOR COMPARISON OF
 REVISIONS WHEN REVIEWING THE RESUBMITTED
 PLANS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
  
 THE CODE REFERENCES GIVE ADDITIONAL
 INFO
  
 TELEPHONE: (561) 805 6716ROBERT
 BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-12-09 Cont ID  
Sent By rbrown Date 2004-12-09 Time 10:30 Rev Time 0.00
Received By rbrown Date 2004-12-09 Time 10:30 Sent To FIRE
Notes
2004-12-09 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
 F.S.= FLORIDA (STATE) STATUTE
  
 1) 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2) 481.219 F.S.CERTIFICATE OF
 AUTHORIZATION.THE TITLE BLOCK FOR ANY
 SHEET BEARING THE NAME OF AN ARCHITECT
 PRACTICING UNDER A FICTITIOUS NAME, A
 CORPORATION, OR A PARTNERSHIP, OFFERING
 ARCHITECTURAL SERVICES, SHALL INCLUDE
 THE CERTIFICATE OF AUTHORIZATION
 NUMBER.ADD THE NUMBER TO EACH SHEET.
 THIS MAY BE ADDED BY HAND.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-02-14 Cont ID  
Sent By dpalmer Date 2005-02-14 Time 17:17 Rev Time 0.25
Received By dpalmer Date 2005-02-14 Time 17:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2005-02-11 Cont ID  
Sent By dpalmer Date 2005-02-11 Time 07:58 Rev Time 0.25
Received By dpalmer Date 2005-02-11 Time 07:58 Sent To  
Notes
2005-02-11 00:00:00************ UNSAT 3RD REVIEW *******
  
 1)NOTE: PLEASE SEE TITLE BLOCK HAS BEEN
 CORRECTED ON PART OFPLANS, HOWEVER,
 PLEASE SEE LOWER RIGHT TITLE BLOCK
 BELOW
 ENGINEER'S AND ALSO ALL OTHER SHEETS
 STILL REFERENCE FIRM.
 FS 481.219, FAC 61G1-16.004
  
 ELEC SHEETS HAVE BEEN VOIDED.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-12-28 Cont ID  
Sent By dpalmer Date 2004-12-28 Time 18:40 Rev Time 0.20
Received By dpalmer Date 2004-12-28 Time 18:40 Sent To  
Notes
2004-12-28 00:00:00*** UNSAT 2ND REVIEW ***
  
 1)NOTE: PLEASE SEE COMMENTS FROM
 PREVIOUS REVIEW.
 PLEASE SEE PLANS HAVE HAD A # ADDED TO
 TITLE BLOCK WITH REFERENCE TO THE CERT
 OF AUTH #. THIS # DOES NOT APPEAR ON
 THE
 STATE DBPR SITE. THE ONLY REFERENCE TO
 A
 YOSHINO/FIRM IS ATTACHED TO NOTES AND
 IS
 IN THE APPLICATION PROCESS.
 LICENSEE INFORMATION
 NAME: YOSHINO BERENBAUM ARCHITECTS
 AIA
 (PRIMARY NAME)
 (DBA NAME)
 MAIN ADDRESS: 7860 GLADES ROAD
 SUITE 225
 BOCA RATONFLORIDA33434
 COUNTY: PALM BEACH
  
 LICENSE MAILING:
  
  
 LICENSELOCATION:
  
  
  
 LICENSE INFORMATION
 LICENSE TYPE: ARCHITECT BUSINESS
 RANK:
 LICENSE NUMBER:
 STATUS: APPLICATION IN PROGRESS
 LICENSURE DATE:
 EXPIRES:
  
 PLEASE SEE ATTACHED.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-11-18 Cont ID  
Sent By dpalmer Date 2004-11-18 Time 06:06 Rev Time 0.10
Received By dpalmer Date 2004-11-18 Time 06:06 Sent To  
Notes
2004-11-18 00:00:00******* UNSAT ********
  
 1)NOTE: PLEASE SEE MISSING INFORMATION
 REQUIRED ON TITLE BLOCKS FOR ARCHITECTS
 FIRM. FS 481.219, FAC 61G1-16.004
 THIS IS REQUIRED ON ALL SHEETS AND FOR
 ALL TRADES WHEATHER OR NOT COMMENT IS
 MADE BY OTHER REVIEWERS.
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWERS WHICH MAY HAVE AN AFFECT
 ON ELECTRICAL PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-01-05 Cont ID  
Sent By nmccray Date 2004-12-16 Time 11:00 Rev Time 0.00
Received By mcarsill Date 2005-01-05 Time 17:14 Sent To  
Notes
2004-12-16 00:00:00FIRE REVIEW PLEASE REF NFPA 101 LIFE
 SAFETY CODE 2000 EDITION
  
 1) EXIT DOORS ARE REQUIRED TO SWING IN
 DIRECTION OF EGRESS TRAVEL WHERE
 SERVING
 A ROOM OR AREA WITH AN OCCUPANT LOAD OF
 50 OR MORE.
  
 2) A DOOR SHALL SWING IN THE DIRECTION
 OF TRAVEL WHERE USED IN AN EXIT
 ENCLOSURE. AND DURING ITS SWING, ANY
 DOOR IN A MEANS OF EGRESS SHALL LEAVE
 NOT LESS THAN ONE-HALF OF THE REQUIRED
 WIDTH OF AN AISLE, CORRIDOR, PASSAGEWAY,
 OR LANDING, WHEN FULLY OPEN.
  
 3) INTERIOR WALL AND CEILING FINISH
 COMPLYING WITH 10.2.3 SHALL BE CLASS
 "A"
 OR CLASS "B" IN EXITS AND ENCLOSED
 CORRIDORS FURNISHING ACCESS TO EXITS;
 AND CLASS "A", CLASS "B", OR CLASS "C"
 IN OFFICE AREAS.
  
 4) SEPARATE PLANS AND PERMIT
 APPLICATIONS ARE REQUIRED FOR FIRE
 SPRINKLER AND FIRE ALARM SYSTEMS
 REMODEL.
  
  
 NATE MCCRAY, CAPTAIN
 561-835-2910 OR 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-01-19 Cont ID  
Sent By mjacobs Date 2005-01-19 Time 14:24 Rev Time 0.00
Received By mjacobs Date 2005-01-19 Time 14:24 Sent To  
Notes
2005-01-19 00:00:00TO "COMM BD#57"

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-12-23 Cont ID  
Sent By mjacobs Date 2004-12-23 Time 14:42 Rev Time 0.00
Received By mjacobs Date 2004-12-23 Time 14:42 Sent To  
Notes
2004-12-23 00:00:00TO "COMM BD#22

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-02-15 Cont ID  
Sent By rbrown Date 2004-12-16 Time 16:42 Rev Time 0.00
Received By rbrown Date 2004-11-10 Time 14:49 Sent To  
Notes
2004-11-10 00:00:00TO COMM BD#34


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved