| Plan Review Stops For Permit 04110390 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-03-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-03-23 |
Time |
17:39 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-03-23 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2005-03-23 00:00:00 | BUILDING REVIEW PROVISO: | | | PROVIDE THE FOLLOWING PRIOR TO | | | INSTALLATION OR CONSTRUCTION TO AVOID | | | CONFLICTS OR DELAYS: | | | | | | 1- FLORIDA OR LOCAL PRODUCT APPROVAL FOR | | | FIXED TRANSOM WINDOWS ABOVE SLIDING | | | GLASS DOORS. THEY EXCEED THE MAX. SIZE | | | ALLOWED ON PRODUCT APPROVAL SUBMITTED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-02-14 |
Time |
16:50 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2005-02-14 |
Time |
16:12 |
Sent To |
PC |
|
| Notes |
| 2005-02-14 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- EXTERIOR ELEVATIONS STILL DON'T SHOW | | | THE CHIMNEY AS REQUESTED ON PREVIOUS | | | CHECKLIST. AND, SPECIFY CHIMNEY HEIGHT | | | AS REQ'D BY SEC. 2804.2.4 FBC 2001. | | | | | | 2- FIREPLACESPECS SUBMITTED ARE FOR A | | | 42" WOOD BURNING FIREPLACE. SPECS | | | CLEARLY INDICATE THAT ALTERATION OF | | | THESE SPECS WILL VOID THE WARRANTY. | | | PROVIDE MANUFACTURER'S CERTIFCATION THAT | | | WARRANTY WILL NOT BE VOID IF CHIMNEY CAP | | | IS INSTALLED AND PROVIDE COMPLETE SPECS | | | FOR CAP CONSTRUCTION. EG: MATERIALS, | | | CLEARANCES, COMPLETE FRAMING (INCLUDING | | | CORNERS), ETC.SECTION 104.2.1.2 CITY | | | AMENDEMNTS TO FBC 2001. | | | **NOTE: ARCHITECT'S LETTER ALONE DOESN'T | | | CLARIFY ISSUE. MANUFACTURER RESPONSE IS | | | REQUIRED TO ASSURE PROPER AND SAFE | | | FUNCTIONING OFFIREPLACE. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | 3- ROOF FRAMING PLAN: A) ENTRY PORCH | | | SHOWS INCORRECT TRUSS BEARING HEIHGT. | | | SEE DETAILS E/6 AND G1 AND G2 OF A6. | | | B) ENTRY PORCH ARE NOT ENGINEERED | | | TRUSSES BUT WOOD BEAMS. REVISE AS REQ'D. | | | C) DETAIL L/6 SHOWN ON BAY WINDOW WAS | | | KEYED WRONG. IT SHOULD BE M/6. | | | D) DETAIL M/6 DOESN'T MATCH ROOF FRAMING | | | PLAN. ROOF FRAMING PLAN CALLS FOR | | | MASONRY BEAM. DETAIL M/6 SHOW WOOD | | | FRAMING. SPECIFY CORRECT CONNECTORS: WOD | | | TO WOOD OR WOOD TO MASONRY AS REQUIRED. | | | REVISE ROOF FRAMING PLAN AND DETAIL AS | | | REQUIRED. | | | E) SPECIFY FIREBLOCKING ON DETAIL M/6 AS | | | REQUIRED. SEC. 2305.1 FBC 2001. | | | F) HOW ARE 2X6 WOOD STUDS SPACED AT | | | 16"0.C TO FORM CHIMNEY AS SHOWN ON FRONT | | | ELEVATION. | | | G) REVISE ROOF LOADS. ROOF FRAMING PLAN | | | CALLS FOR ATTIC STORAGE, THEN, NEED TO | | | INCREASE ATTIC LIVE LOAD TO 30PSF AS | | | REQ'D BY TABLE 1604.1 FBC 2001. | | | | | | 4- DOUBLE ARCHED WINDOWS AT BEDROOM #2: | | | A) SPECIFY HOW IS STEEL TUBE ATTACHED AT | | | TOP AND BOTTOM. | | | B) HOW IS 2X BLOCKING ATTACHED TO STEEL | | | TUBE. SEC. 104.2.1.2 CITY AMENDMENTS TO | | | FBC 2001. | | | | | | 5- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: | | | A) FIXED WINDOWS FOR LARGER WINDOWS AS | | | SHOWN ON FAMILY ROOM & LIVING ROOM. | | | B) EXTERIOR SWING DOOR AT GARAGE. | | | | | | 6- BBQ SPECS SAY "DO NOT INSTALL A GRILL | | | BELOW OVERHEAD UNPROTECTED COMBUSTIBLE | | | CONSTRUCTION" HOW IS THIS BBQ GOING TO | | | BE INSTALLED IN THE PORCH AND FOLLOW | | | MANUFACTURER SPECS. | | | **NOTE: I CALLED THE MANUFACTURER AND | | | THEY SAID BBQ ARE NOT INTENDED TO BE | | | USED IN PORCHES. THEY SAY IS FOR | | | OUTDOORS INSTALLATION ONLY. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-12-08 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-12-08 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2004-12-08 00:00:00 | CHECKLIST: | | | 1-AREA CALCS ON SHEET A1 DON'T ADD UP | | | CORRECTLY. REVISE AS REQUIRED. | | | | | | 2-REVISE DETAILS C1 AND C2 ON SHEET A6 | | | TO MATCH ACTUAL CONDITIONS SHOWN ON | | | ROOF | | | FRAMING PLAN. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 3-PROVIDE COMPLETE DETAILS AND | | | SPECIFICATIONS FOR CANTILEVERED BEAM AT | | | BREAKFAST AREA. SPECIFY HOW ARE PRECAST | | | LINTELS JOINED AT THE 45 DEGREE ANGLE | | | AND HOW ARE THEY ATTACHED TO THE ENDS | | | TO | | | TRANSFER THE ROOF LOADS TO THE COLUMNS. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | | | 4-FOUNDATION PLAN AND FLOOR PLAN DON'T | | | MATCH. SEE LOCATION OF BBQ. ALSO, SHOW | | | WHERE IS BBQ SUPPORTED ON?. SECTION | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | 5-PROVIDE COMPLY SECTION/DETAIL FOR BAY | | | WINDOW AT GARAGE AREA. SPECIFY ALL | | | MATERIALS AND FASTENERS. SEC. 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | | | | 6-SHEET A3: A) REVISE ROOF SHEATHING | | | NOTE. SEE FIGURE 1606.2(C) FBC 2001 AND | | | CLEARLY IDENTIFY ALL ZONES CONSIDERED | | | TO | | | BE ZONE 3. (NOT JUST THE 4 CORNERS). | | | B) REVISE ROOF LOADS CHART. SEE TABLE | | | 1604.1 FBC 2001. | | | **NOTE: KEEP IN MIND THAT ROOF FRAMING | | | PLAN CALLS FOR ATTIC STORAGE. | | | | | | 7-PROVIDE DETAIL/SECTION FOR FRAMING AT | | | DOUBLE ARCHED WINDOWS MULLED TOGETHER | | | AS | | | SHOWN ON BEDROOM #2. SEC. 104.2.1.2 | | | CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 8-A) ELEVATIONS DON'T SHOW CHIMNEY. | | | B) ARCHITECT TO CHECK FIREPLACE SPECS | | | TO | | | VERIFY IF CHIMNEY ROOF CAP IS ALLOWED | | | WITHOUT INTERFERING WITH FLUE FUNCTION. | | | (NOTE: SOME COMPANIES DON'T ALLOW IT). | | | | | | 9-PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: | | | A) BUTT GLAZING SYSTEM AS SHOWN ON | | | PLANS | | | B) ENTRY DOORS. | | | C) FIREPLACE UL LISTING & COMPLETE | | | SPECS | | | D) SIZE OF FIXED WINDOWS AS SHOWN ON | | | LIVING AND FAMILY ROOM AREAS. | | | E) BBQ UL LISTING AND SPECS. | | | | | | 10-PROVIDE STORM SHUTTERS PRODUCT | | | APPROVAL AND COMPLETE INFORMATION (KEY | | | PLAN, INSTALLATION SCHEDULE AND | | | SPECIFIC | | | ANCHORS) FOR BUTT GLAZING PROTECTION. | | | | | | 11-OWES $2378.71 FOR UPDATED VALUATION | | | AND RADON FEES. | | | | | | 12-SPECIFICATIONS ON ROOF FRAMING PLAN | | | FOR CHIMNEY DON'T MATCH DETAIL/SECTION | | | ON SHEET A6. REVISE AS REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO AT (561)805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-24 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-24 |
Time |
11:02 |
Sent To |
PC |
|
| Notes |
| 2006-03-24 00:00:00 | REDLINED FEEDERS FOR SUB PANEL "C" TO BE | | | AS SHOWN ON RISER. PANEL SCHEDULE IS NOT | | | CORRECT. OK PER RISER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-03-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-08 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-08 |
Time |
07:56 |
Sent To |
PC |
|
| Notes |
| 2006-03-08 00:00:00 | REDLINED FEEDERS FOR SUB PANEL "C" TO BE | | | AS SHOWN ON RISER. PANEL SCHEDULE IS NOT | | | CORRECT. OK PER RISER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-02-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-15 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-15 |
Time |
14:13 |
Sent To |
PC |
|
| Notes |
| 2006-02-15 00:00:00 | REDLINED MISSING RECEPT(S) FOR 2' OF | | | WALL SPACE. 210.52 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-03 |
Time |
21:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-03 |
Time |
20:32 |
Sent To |
PC |
|
| Notes |
| 2006-02-03 00:00:00 | ************ UNSAT ************ | | | | | | | | | 1)NOTE:*** PLEASE KNOW, A "PROVISO" WAS | | | GIVEN ON JAN 31, OF 2005 FOR PLANS AND | | | LOAD CALCULATIONS TO BE REVISED ALONG | | | WITH ANY OTHER REVISIONS BEFORE ROUGH. | | | THIS WAS NOT DONE. | | | PLEASE SEE THERE ARE MANY REVISIONS TO | | | PLANS WHICH WERE NEVER SUBMITTED. | | | PLANS ARE NOW ONLY COMING IN FOR | | | REVISIONS ONE YEAR TO DATE. | | | ** PLEASE SEE THE FOLLOWING COMMENTS AS | | | SOME LOADS HAVE INCREASED, HOWEVER | | | SERVICE HAS NOT. | | | 215.5 | | | | | | 2)NOTE: PLEASE CORRELATE RISER DIAGRAM , | | | PANELS AND PLANS. PLEASE SEE PANEL "A" | | | SHOWS A 2-POLE 60A BRKR FEEDING POOL | | | PANEL , HOWEVER POOL PANEL IS NOW SHOWN | | | AS 80A'S ON PLANS AND RISER?? | | | PLEASE ALSO SEE LOADS INDICATED ON PANEL | | | "C" DO NOT CORRELATE WITH LOADS SHOWN ON | | | PANEL "A". | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE 220.18 FOR MIN KW | | | RATING WHICH SHALL BE FIGURED FOR THE | | | DRYER. | | | | | | 4)NOTE: PLEASE SEE THAT THE MAX OCP FOR | | | THE OVEN RECEPT SHALL BE 50A'S. | | | PLEASE SEE OVEN IS SHOWN WIHT A RECEPT | | | AND NOT HARDWIRED. | | | PLEASE SEE 210.21B3 | | | | | | 4)NOTE: PLEASE CORRELATE AHU'S #1 AND #2 | | | KW RATINGS AS LOADS FIGURED INTO LOAD | | | CALCULATIONS DO NOT MATCH WITH THE KW | | | RAITNG SHOWN ON PANEL SCHEDULE(S) | | | FITGURED AT 65%. | | | PLEASE ALSO SEE KW RATING FOR AHU#3 DOES | | | NOT CORRELATE WITH LOAD CALCULATIONS. | | | 215.5 | | | | | | 5)NOTE: PLEASE SEE TWO A/C COMP #1'S ARE | | | SHOWN , HOWEVER A/C COMP #3 IS NOT SHOWN | | | ?? | | | 215.5 | | | | | | 6)NOTE:PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | PLEASE ADJUST LOAD CALCS. | | | | | | 7)NOTE: PLEASE SEE WHAT APPEARS TO BE A | | | MISSING GFI ON KITCHEN ISLAND AS | | | REQUIRED FOR ISLANDS AND SEPARATE SPACES | | | SEPARATED BY SINKS ETC. | | | 210.52C2 AND C4. | | | | | | 8)NOTE: PLEASE VERIFY THREE FULL SIZE | | | #6'S AND #8 TO AHU'S. | | | PLEASE SEEEQUIPMENT GROUNDING | | | CONDUCTORS MAY BE SIZED AS SHOWN , | | | HOWEVER MAY ALSO BE SIZED PER 250.122 | | | IF PLANS INDICATE A #6 AND #8 FOR THE | | | EQUIPMENT GRNDS, THEY WILL BE REQUIRED | | | OT BE INSTALLED. | | | THIS IS ONLY A NOTE: | | | | | | 9)NOTE: PLEASE SEE CONTINUOUS LOADS | | | SHALL BE FIGURED AT 125% IN PANEL | | | CALCULATIONS.(POOL PUMP) | | | 215.3,230.42. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-31 |
Time |
15:05 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-01-31 |
Time |
14:48 |
Sent To |
P |
|
| Notes |
| 2005-01-31 00:00:00 | ********** PROVISO/REVISION ********* | | | | | | 210.52MISSING RECEPT IN BEDRM #5(NOTED | | | ON PREVIOUS NOTES ). | | | | | | | | | 2 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | PLEASE ADJUST LOAD CALCS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION | | | ALONG WITH ANY OTHER REVISIONS BEFORE | | | ROUGH ELECTRICAL INSPECTION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-12 |
Time |
22:23 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2004-11-12 |
Time |
22:23 |
Sent To |
M |
|
| Notes |
| 2004-11-12 00:00:00 | ************* UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE MISSING REQUIRED | | | EGRESS LT/ CONTROL BEDRM #5 210.70 | | | | | | 2)NOTE: PLEASE ALSO SEE MISSING RECEPT | | | FOR 2' OF WALL SPACE. IN BEDRM 5. | | | 210.52 | | | | | | 3)NOTE: PLEASE MOVE SD INTO MASTER BEDRM | | | AREA. PLEASE SEE NFPA-72 FOR SD | | | PLACEMENT. | | | 8-1.4.1.6.2 | | | | | | 4)NOTE: PLEASE SEE BOTH SETS OF PLANS | | | AND ALL SHEETS FOR ALL TRADES ARE SEALED | | | | | | PHOTO-COPIES OF SIGNATURE. | | | PLEASE SEE THIS HAS BEEN COMMENTED ON ON | | | PREVIOUS PROJECTS AND PREVIOUS REVIEWS | | | FOR THOSE PROJECTS. | | | THE SIGNATURE IS REQUIRED TO BE ORIGINAL | | | SIGNATURE. FS 481.221 AND FAC | | | 61G1-16.004 | | | ONE COPY OF ONE SET IS BEING RETAINED | | | FOR FILE AND POSSIBLE REVIEW BY BOARD OF | | | ARCH'S. | | | THIS NOTE STANDS FOR ALL SHEETS AND ALL | | | TRADES WHEATHER OR NOT COMMENT IS MADE | | | BY OTHER REVIEWERS. | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-06 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-06 |
Time |
12:14 |
Sent To |
E |
|
| Notes |
| 2006-03-06 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-06 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-06 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2006-03-06 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-02-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-13 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-13 |
Time |
16:15 |
Sent To |
E |
|
| Notes |
| 2006-02-13 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-02-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-01 |
Time |
18:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-01 |
Time |
18:46 |
Sent To |
E |
|
| Notes |
| 2006-02-01 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-10 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-10 |
Time |
11:15 |
Sent To |
B |
|
| Notes |
| 2005-03-10 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-27 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-27 |
Time |
10:21 |
Sent To |
E |
|
| Notes |
| 2005-01-27 00:00:00 | TO "DP" DESK/RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-08 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-12 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2004-11-12 00:00:00 | TO SFD RACK/E | | 2004-11-09 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-02-14 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
prafter |
Date |
2005-02-14 |
Time |
10:30 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-18 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2004-11-18 |
Time |
14:32 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2004-11-18 |
Time |
14:31 |
Sent To |
P |
|
| Notes |
| 2004-11-18 00:00:00 | PAT RAFTER805 6719 | | | NOTE; NO SIZE ON R/A GRILL FOR AHU [1] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-03-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-09 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-03-09 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-02-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-02-11 |
Time |
11:02 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-02-11 |
Time |
11:02 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-11-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-22 |
Time |
05:47 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-11-22 |
Time |
05:47 |
Sent To |
B1 |
|
| Notes |
| 2004-11-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | | | | 1) SHT A4 SANITARY RISER DIAGRAM AT THE | | | WASH MACHINE/LAUNDRY SINK DOES NOT MEET | | | CODE REQUIREMENTS. | | | A) A STANDPIPE IS REQUIRED PER SECTION | | | 1002.1 | | | B) THE CLEANOUT SHALL BE LOCATED 4 FEET | | | ABOVE THE FLOOR FOR ACCESS SECTION | | | 708.10 | | | C) DOUBLE SANITARY TEE PATTERNS SHALL | | | NOT RECEIVE THE DISCHARGE OF APPLIANCES | | | WITH PUMPING ACTION DISCHARGE. SECTION | | | 706.3 | | | | | | 2) ARCHITECT'S SIGNATURE IS A COPY ON | | | ALL SHEETS. COPIES OF SIGNATURES IS NOT | | | APPROVED. FAC 61G1-16.004(5) & FS | | | 481.221 | | | | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-11-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-11-10 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-11-10 |
Time |
16:33 |
Sent To |
I |
|
| Notes |
| 2004-11-10 00:00:00 | NOTE: MUST PULL SEPERATE PERMIT FOR POOL | | | & DECK. |
|
|