Plan Review Details - Permit 04110388
Plan Review Stops For Permit 04110388
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-10-03 Cont ID  
Sent By jgomez Date 2005-10-03 Time 08:05 Rev Time 0.33
Received By jgomez Date 2005-10-03 Time 08:05 Sent To PC
Notes
2005-10-03 00:00:00BUILDING REVIEW CHECKLIST:
 1- PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOORS THAT MATCH ENTRY DOORS SHOWN ON
 PLANS. PRODUCT APPROVAL SUBMITTED IS FOR
 FRENCH DOORS WITH SIDELITES ASSEMBLIES.
 NEED PRODUCT APPROVAL FOR FRENCH DOORS
 WITHOUT SIDELITES AS SHOWN ON PLANS.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-08-24 Cont ID  
Sent By jgomez Date 2005-08-24 Time 17:37 Rev Time 0.50
Received By jgomez Date 2005-08-24 Time 17:37 Sent To E
Notes
2005-08-24 00:00:00BUILDING REVIEW CHECKLIST:
  
 1- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR MISSILE IMPACT ENTRY DOORS
 AS SPECIFIED ON PLANS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-12-06 Cont ID  
Sent By jgomez Date 2004-12-06 Time 16:43 Rev Time 2.50
Received By jgomez Date 2004-12-06 Time 16:43 Sent To PC
Notes
2004-12-06 00:00:00BUILDING REVIEW PROVISO:
 1-PROVIDE FLORIDA/LOCAL PRODUCT APPROVAL
 FOR 2X STRUCTURAL MULLION AS SPECIFIED
 ON ARCHITECTURAL PLANS.
  
 2-PROVIDE PRODUCT APPROVAL FOR MISSILE
 IMPACT ENTRY DOORS AS SPECIFIED ON
 ARCHITECTURAL PLANS.
  
 3-A) REVISE ENTRY COLUMN DETAIL TO SHOW
 WHERE ARE 2X12'S BEAMS RESTING ON.
 B) PROVIDE DETAIL SHOWIN HOW ARE 2X12'S
 ENTRY PORCH BEAMS RESTING ON THE
 MASONRY
 SIDE. SECTION 104.2.1.2 CITY AMENDMENTS
 TO FBC 2001.
  
 4-PROVIDE ENTRY PORCH DETAILS THAT MATCH
 ACTUAL CONDITIONS SHOWN ON ROOF FRAMING
 PLANS. SEE ROOF FRAMING PLAN, COMPARE TO
 DETAILSC1 AND C2 ON SHEET A6 SUBMITTED
 AND REVISE THEM AS REQUIRED. SEC.
 104.2.1.2 CITY AMENDMENTS
  
 5-SHEET A-3: A) REVISE ROOF LOADS CHART
 TO INCLUDE THE ATTIC LIVE LOAD REQUIRED
 BY TABLE 1604.1 FBC 2001
 B)REVISE ROOF SHEATHING NOTE. SEE FIGURE
 1606.2(C) FBC 2001 FOR CORRECT ZONE 3.
  

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2005-12-06 Cont ID  
Sent By dpalmer Date 2005-12-06 Time 10:25 Rev Time 0.00
Received By dpalmer Date 2005-12-06 Time 10:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-09-27 Cont ID  
Sent By dpalmer Date 2005-09-27 Time 08:12 Rev Time 0.00
Received By dpalmer Date 2005-09-27 Time 08:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-08-29 Cont ID  
Sent By dpalmer Date 2005-08-29 Time 10:05 Rev Time 0.25
Received By dpalmer Date 2005-08-29 Time 10:05 Sent To  
Notes
2005-08-29 00:00:00REDLINED SD FOR MASTER BEDRM, TO BE
 MOVED INTO BEDRM AREA.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-08-26 Cont ID  
Sent By dpalmer Date 2005-08-26 Time 16:38 Rev Time 0.25
Received By dpalmer Date 2005-08-26 Time 16:40 Sent To  
Notes
2005-08-26 00:00:00************ UNSAT *************
  
 1)NOTE: PLEASE SEE ONLY ONE SET OF
 ELECTRICAL REVISED SHEETS WERE
 SUBMITTED.
  
 2)NOTE: PLEASE SEE REDLINED SD LOCATION
 IN MASTER BEDRM FROM PREVIOUS REVIEW NOT
 CORRECTED.
 PLEASE MOVE SD INOT MASTER BEDRM AREA.
 SD'S ARE TO BE LOCATED WITHIN 3' OF ANY
 PEAK ON A SLOPED CEILING AND 12" FROM A
 FLAT CEILING.
 NFPA-72 CHAPTER 2
  
 3)NOTE: PLEASE SEE PLANS SUBMITTED AS A
 "SUBMITTAL". REVISION FEES ARE OWED.
  
 4 )NOTE: PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-11-12 Cont ID  
Sent By dpalmer Date 2004-11-12 Time 22:44 Rev Time 0.33
Received By dpalmer Date 2004-11-12 Time 22:44 Sent To M
Notes
2004-11-12 00:00:00*** NOTE REDLINED ***
  
 SD IN MASTER BEDRM, TO BE MOVED "INTO"
 BEDRM AREA.
 NFPA-72 8-1.4.1.6.2

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-11-29 Cont ID  
Sent By adarroug Date 2005-11-29 Time 14:14 Rev Time 0.00
Received By adarroug Date 2005-11-29 Time 14:14 Sent To E
Notes
2005-11-29 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-09-23 Cont ID  
Sent By adarroug Date 2005-09-23 Time 18:19 Rev Time 0.00
Received By adarroug Date 2005-09-23 Time 18:19 Sent To B
Notes
2005-09-23 00:00:00TO "JGOMEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-09-23 Cont ID  
Sent By adarroug Date 2005-09-23 Time 18:16 Rev Time 0.00
Received By adarroug Date 2005-09-23 Time 18:16 Sent To E
Notes
2005-09-23 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-07-08 Cont ID  
Sent By adarroug Date 2005-07-08 Time 11:45 Rev Time 0.00
Received By adarroug Date 2005-07-08 Time 11:45 Sent To B
Notes
2005-07-08 00:00:00TO "JGOMEZ"DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-12-17 Cont ID  
Sent By mjacobs Date 2004-12-17 Time 14:44 Rev Time 0.00
Received By mjacobs Date 2004-12-17 Time 14:44 Sent To B
Notes
2004-12-17 00:00:00SENT TO "JG" DESK/SUBMITTALS.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-12-15 Cont ID  
Sent By mjacobs Date 2004-12-15 Time 16:26 Rev Time 0.00
Received By mjacobs Date 2004-12-15 Time 16:26 Sent To P
Notes
2004-12-15 00:00:00SENT TO "P" BOX.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-12-06 Cont ID  
Sent By jgomez Date 2004-12-06 Time 16:53 Rev Time 0.00
Received By jgomez Date 2004-11-12 Time 16:07 Sent To PC
Notes
2004-11-12 00:00:00TO SFD RACK/E
2004-11-09 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-12-15 Cont ID  
Sent By drunnels Date 2004-11-17 Time 15:15 Rev Time 0.00
Received By drunnels Date 2004-11-18 Time 14:15 Sent To  
Notes
2004-11-18 00:00:00PAT RAFTER805 6719

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-08-29 Cont ID  
Sent By jleech Date 2005-08-29 Time 08:08 Rev Time 0.50
Received By jleech Date 2005-08-29 Time 08:08 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-12-29 Cont ID  
Sent By jleech Date 2004-12-29 Time 16:40 Rev Time 0.50
Received By jleech Date 2004-12-29 Time 16:39 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-11-22 Cont ID  
Sent By kstevens Date 2004-11-22 Time 06:10 Rev Time 0.33
Received By kstevens Date 2004-11-22 Time 06:10 Sent To B1
Notes
2004-11-22 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
  
 1) SHT A4 SANITARY RISER DIAGRAM DOES
 NOT REFLECT THE FLOOR PLAN.
 A) BATH #4 SHOWS A TUB TO THE LEFT OF
 THE W/C. RISER DIAGRAM SHOWS A TUB TO
 THE RIGHT OF THE W/C.
 B) MASTER BATH SHOWS A BIDET TO THE
 RIGHT OF THE W/C. RISER DIAGRAM SHOWS
 THE BIDET BETWEEN THE W/C AND LAVS.
 C) MASTER BATH SHOWS TWO LAVS ON THE
 SAME WALL. RISER DIAGRAM SHOWS LAVS ON
 DIFFERENT WALLS.
 PLEASE CORRELATE RISER DIAGRAM WITH THE
 FLOOR PLAN. SECTION 104.2.1.
  
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-11-10 Cont ID  
Sent By mmclean Date 2004-11-10 Time 16:38 Rev Time 0.00
Received By mmclean Date 2004-11-10 Time 16:38 Sent To I
Notes
2004-11-10 00:00:00NOTE: MUST PULL SEPERATE PERMIT FOR POOL
 & DECK.