| Plan Review Stops For Permit 04110346 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2005-03-22 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-03-22 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2005-03-22 00:00:00 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | --PROVISO-- | | | 489.103 F.S. SHEET S-1, STRUCTURAL PLAN. | | | CUTTING/REINSTATEMENT OF THE ROOF AND | | | FLOOR SLABS IS OUTSIDE THE SCOPE OF | | | LICENSURE FOR THE MECHANICAL AND | | | ELECTRICAL CONTRACTORS.THIS WORK SHALL | | | BE SUB-CONTRACTED TO A LICENSED GENERAL | | | CONTRACTOR. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-17 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2005-03-17 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-03-17 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2005-03-17 00:00:00 | BUILDING PLAN REVIEW | | | ******DENIED******** | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | SHEET S-1, FOUNDATION PLAN WAS PASSED | | | WITH PROVISO AND STAMPED AFTER THE LAST | | | REVIEW.WHEN THE PLANS WERE | | | RESUBMITTED, TO ADDRESS THE ELECTRICAL | | | PLAN REVIEW COMMENTS, ONLY ONE COPY OF | | | SHEET S-1 WAS INCLUDED.SUBMIT THE | | | OTHER COPY OR TWO NEW COPIES (OMITTING | | | THE ROOF FRAMING DETAILS) OF SHEET S-1. | | | | | | --PROVISO FROM LAST REVIEW-- | | | 489.103 F.S. SHEET S-1, STRUCTURAL PLAN. | | | CUTTING/REINSTATEMENT OF THE ROOF AND | | | FLOOR SLABS IS OUTSIDE THE SCOPE OF | | | LICENSURE FOR THE MECHANICAL AND | | | ELECTRICAL CONTRACTORS.THIS WORK SHALL | | | BE SUB-CONTRACTED TO A LICENSED GENERAL | | | CONTRACTOR. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-12-08 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-12-08 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-12-08 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2004-12-08 00:00:00 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | --PROVISO-- | | | 489.103 F.S. SHEET S-1, STRUCTURAL PLAN. | | | CUTTING/REINSTATEMENT OF THE ROOF AND | | | FLOOR SLABS IS OUTSIDE THE SCOPE OF | | | LICENSURE FOR THE MECHANICAL AND | | | ELECTRICAL CONTRACTORS.THIS WORK SHALL | | | BE SUB-CONTRACTED TO A LICENSED GENERAL | | | CONTRACTOR. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-02-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-15 |
Time |
04:04 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-02-15 |
Time |
04:04 |
Sent To |
|
|
| Notes |
| 2005-02-15 00:00:00 | *** | | | VALUE FOR SCOPE OF WORK TO BE INCREASED | | | FOR COMPLETE SCOPE OF WORK. | | | NO CONTRACT INFORMATION PROVIDED. | | | VALUE TO INCLUDE: | | | ALL ELECTRICAL ASSOCIATED WITH | | | INSTALLATION OF NEW GEN/ ATS/DISC'S ETC. | | | GENERATOR,AND ALL ELECTRICAL EQUIPMENT. | | | NEW DIEISEL FIRE PUMP. | | | PLUMB/MECH WORK. | | | | | | | | | VALUE SHOWN AT $155K AT THIS TIME. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-11-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-29 |
Time |
08:03 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-11-29 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2004-11-29 00:00:00 | ******* UNSAT ******** | | | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002 FOR | | | MISSING LICENSE INFORMATION REQUIRED ON | | | TITLE BLOCKS. PLEASE SEE FS 471.023 FOR | | | REQUIRED CA #. | | | THIS IS REQUIRED ON ALL SHEETS AND FOR | | | ALL TRADES WHEATHER OR NOT COMMENT IS | | | MADE BY OTHER REVIEWERS. MECH/FIRE | | | STAMPS HAVE BEEN VOIDED. | | | PLEASE PROVIDE NEW SHEETS FOR TRADES. | | | | | | 2)NOTE: PLEASE PROVIDE COPY OF | | | COMPPLETE | | | CONTRACT FOR SCOPE OF WORK. VALUE IS TO | | | BE BASED ON LABOR AND MATERIALS. THIS | | | WOULD INCLUDE GEN ETC. EVEN IF OWNER | | | SUPPLIED. FBC 104.6.5. | | | VALUE SHOWN AT $155K. | | | IF VALUE SHOWN ON ELECTRICAL PERMIT | | | APPLICATION IS TO BE ADDED TO MECH | | | PERMIT APPLICATION , PLEASE ADJUST MECH | | | PERMIT APPLICATION. | | | | | | 3)NOTE: PLEASE ALSO SUBMIT MANUFACT. | | | SPECS ON NEW TRANSFER SWITCH. | | | | | | 4)NOTE: PLEASE SEE # OF CONDUCTORS FROM | | | ATS -2 TO NEW DISC(CODED NOTES #10). | | | SHOWN AS 3-POLE DISC'S AND EQUIPMENT, | | | HOWEVER ONLY 3- CONDUCTORS ARE SHOWN. | | | PLEASE SEE 240.4C, 240.21 FOR SIZING OF | | | CONDUCTORS AND TERMINATION INTO 400A | | | DISC FROM 1000A OCP. | | | PLEASE VERIFY THE ABOVE. | | | | | | 5)NOTE: PLEASE VERIFY GFI PROTECTION ON | | | GENERATOR PER 240.13,230.95. | | | EXISTING EM MAIN, DOES INDICATE GFI | | | PROTECTION. | | | | | | 6)NOTE: PLEASE VERIFY , RISER INDICATES | | | NEW TRANSFER SWITCH (FORMERLY FIRE | | | PUMP)? IS FIRE PUMP FEED BEING REMOVED? | | | IS THERE ALREADY A NEW FEED FOR FIRE | | | PUMP? | | | PLEASE VERIFY. | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-03-10 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-03-10 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2005-03-10 00:00:00 | 1. WHEN THE REQUIRED EXISTING FIRE | | | PUMP IS REMOVED, AN APPROVED FIRE | | | WATCH WILL BE REQUIRED FOR THE | | | BUILDING. PROPER NOTIFICATION IS TO | | | OCCUR WHEN THE FIRE PUMP IS TAKEN | | | OFF-LINE OR REMOVED FROM THE | | | BUILDING. | | | | | | 2. EMERGENCY GENERATOR INSTALLATION | | | TO COMPLY WITH NFPA 110. | | | | | | 3. THE EXHAUST FROM THE GENERATOR | | | SHALL NOT RE-ENTER THE BUILDING. NO | | | BACK FEEDING OF VAPORS ARE TO OCCUR. | | | | | | 4. NEW DAY TANK IS TO BE PROPERLY | | | LABELED WITH STICKERS INDICATING | | | THE PRODUCT NAME, NO SMOKING, ETC. | | | | | | 5. THE NEW FIRE PUMP WHEN INSTALLED | | | SHALL BE INSPECTED, TESTED, AND | | | APPROVED BY THE FIRE PREVENTION | | | BUREAU TO ENSURE PROPER OPERATION. | | | | | | 6. FIRE PUMP INSTALLATION TO COMPLY | | | WITH NFPA 20. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-11-23 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-11-23 |
Time |
16:14 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-03-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-11 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-11 |
Time |
15:05 |
Sent To |
B |
|
| Notes |
| 2005-03-11 00:00:00 | TO RBROWN DESK/TAKEN OFF BD#41 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-22 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-02-09 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2005-02-09 00:00:00 | ORIGINAL OR DUPLICATE PERMIT REQUIRED | | | PRIOR TO PERMIT BEING ISSUED |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-08 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2004-11-05 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2004-11-24 00:00:00 | SENT TO "COMM" BD#14 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-05 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-05 |
Time |
14:27 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-05-18 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-05-18 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-02-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-02-11 |
Time |
07:51 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-02-11 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2005-02-11 00:00:00 | PROVISO: | | | THE GENERATOR EXHAUST SHALL TERMINATE IN | | | SUCH A MANNER THAT TOXIC FUMES CANNOT | | | REENTER A BUILDING OR STRUCTURE THROUGH | | | DOORS, WINDOWS, AIR INTAKES OR THE | | | ENGINE AIR INTAKE SYSTEM.NFPA 110 | | | SECTION 7.10.2. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-11-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-11-22 |
Time |
11:38 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-11-22 |
Time |
11:05 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-03-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-09 |
Time |
17:37 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-03-09 |
Time |
17:37 |
Sent To |
|
|
| Notes |
|
|