Plan Review Details - Permit 04110265
Plan Review Stops For Permit 04110265
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-12-22 Cont ID  
Sent By rmcdouga Date 2004-12-22 Time 15:41 Rev Time 0.00
Received By rmcdouga Date 2004-12-22 Time 15:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-12-06 Cont ID  
Sent By jwitmer Date 2004-12-06 Time 16:30 Rev Time 0.55
Received By jwitmer Date 2004-12-06 Time 16:30 Sent To  
Notes
2004-12-06 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04110265
 ADD: 1710 UPLAND RD
 CONT: ANDERSON MOORE
 TEL: (561)662-1819
  
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) 11-4.24.3 KNEE CLEARENCE THAT IS AT
 LEAST 27" HIGH 30" WIDE, AND 19" DEEP
 SHALL BE PROVIDED UNDERNEATH SINKS.
  
 3) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 4) 1503.4.4 PROTECTION AGAINST DECAY &
 TERMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 5) 1511.7 ROOF MOUNTED MECHANICAL UNIT S
 SHALL BE MOUNTED ON CURBS RAISED A
 MINIMUM OF 8 INCHES ABOVE THE ROOF SUR-
 FACE, OR WHERE ROOFING MATERIALS EXTEND
 BENEATH THE UNIT, ON RAISED EQUIPMENT
 SUPPORTS PROVIDING A MINIMUM CLEARENCE
 HEIGHT IN ACCORDANCE WITH TABLE 1511.7.
 MECH. 301.13 WIND RESISTANCE MECHANICAL
 EQUIPMENT, APPLIANCES AND SUP PORTS THAT
 ARE EXPOSED TO WIND SHALL BE DESIGNED
 AND INSTALLED TO RESIST THE WIND
 PRESSURES ON THE EQUIPMENT & THE
 SUPPORTS AS DETERMINED IN ACCORDANCE
 WITH THE FL BLD CODE. THIS MAY BE ACCOMP
 LISHED BY DESIGN OR BY APPLICATION OF
 SECTION 301.13.1.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-01-26 Cont ID  
Sent By dpalmer Date 2005-01-26 Time 10:44 Rev Time 0.25
Received By dpalmer Date 2005-01-26 Time 10:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-01-04 Cont ID  
Sent By dpalmer Date 2005-01-04 Time 15:30 Rev Time 0.25
Received By dpalmer Date 2005-01-04 Time 15:30 Sent To B
Notes
2005-01-04 00:00:00NEW PME, SIGNED BY THE ENGINEER OF
 RECORD.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-12-29 Cont ID  
Sent By dpalmer Date 2004-12-29 Time 10:36 Rev Time 0.50
Received By dpalmer Date 2004-12-29 Time 10:36 Sent To  
Notes
2004-12-29 00:00:00************ UNSAT *************
  
 PLEASE SEE NEW ELECTRICAL SHEETS
 INSERTED INTO PREVIOUSLY STAMPED PLANS.
  
  
 1)NOTE: PLEASE SEE NOTE ON RISER HAS
 BEEN REVISED TO HAVE EQUIPMENT GROUNDING
 CONDUCTOR FROM MAIN DISC GROUNDED TO
 GRND ROD, COLD WATER AND FOOTER STEEL??
 THIS MUST BE A MISPRINT.
  
 2)NOTE: PLEASE SEE NEW SHEETS AND SETS
 FOR P
 SEALED BY THE ENGINEER RESPONSIBLE FOR
 PLANS. CHANE INC ON TITLE BLOCK.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-11-15 Cont ID  
Sent By dpalmer Date 2004-11-15 Time 16:30 Rev Time 0.50
Received By dpalmer Date 2004-11-15 Time 15:35 Sent To  
Notes
2004-11-15 00:00:00REDLINED SEC'S PER 310.16
 EXST RISER NOTES FPL, YET SEC'S ARE FROM
 WEATHER-HEAD TO METER.
  
 REDLINED POSSIBLE EQUIPMENT GROUNDING
 CONDUCTOR FROM MAIN DISC TO PANEL.
 250.24,250.122

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2004-12-07 Cont ID  
Sent By lmartine Date 2004-12-07 Time 10:37 Rev Time  
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2004-12-07 Cont ID  
Sent By nmccray Date 2004-12-07 Time 12:37 Rev Time 0.00
Received By nmccray Date 2004-12-07 Time 12:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-04-04 Cont ID  
Sent By adarroug Date 2005-04-04 Time 15:59 Rev Time 0.00
Received By adarroug Date 2005-04-04 Time 15:59 Sent To M
Notes
2005-04-04 00:00:00TO "PKRAUSS" BOX/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-03-23 Cont ID  
Sent By adarroug Date 2005-03-23 Time 15:07 Rev Time 0.00
Received By adarroug Date 2005-03-23 Time 15:07 Sent To M
Notes
2005-03-23 00:00:00TO "M" BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-01-21 Cont ID  
Sent By mjacobs Date 2005-01-21 Time 11:47 Rev Time 0.00
Received By mjacobs Date 2005-01-21 Time 11:47 Sent To E
Notes
2005-01-21 00:00:00TO "DP" DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-12-16 Cont ID  
Sent By mjacobs Date 2004-12-16 Time 13:15 Rev Time 0.00
Received By mjacobs Date 2004-12-16 Time 13:15 Sent To  
Notes
2004-12-16 00:00:00SENT TO "COMM BD#17"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-12-22 Cont ID  
Sent By rmcdouga Date 2004-12-22 Time 15:41 Rev Time 0.00
Received By rmcdouga Date 2004-11-05 Time 14:31 Sent To  
Notes
2004-11-05 00:00:00TO COMM BD#31

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2005-04-06 Cont ID  
Sent By pkrauss Date 2005-04-06 Time 08:49 Rev Time 0.35
Received By pkrauss Date 2005-04-06 Time 08:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2005-03-25 Cont ID  
Sent By pkrauss Date 2005-03-25 Time 09:11 Rev Time 0.45
Received By pkrauss Date 2005-03-25 Time 07:45 Sent To  
Notes
2005-03-25 00:00:00DENIED:
 PLANS MUST BE SIGNED AND SEALED BY THE
 ENGINEER.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-12-27 Cont ID  
Sent By shill Date 2004-12-27 Time 12:58 Rev Time 0.00
Received By shill Date 2004-12-27 Time 12:58 Sent To  
Notes
2004-12-27 00:00:00PASSED PER PAT RAFTER

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-12-04 Cont ID  
Sent By pkrauss Date 2004-12-04 Time 05:51 Rev Time 0.40
Received By pkrauss Date 2004-12-04 Time 05:49 Sent To  
Notes
2004-12-04 00:00:00DENIED:
 1.PLAN SHEET 3.1 & 8.1 INDICATE THE
 SEPARATION BETWEEN THE WAREHOUSE AND THE
 OFFICE AREA HAS A 2 HR FIRE RATING.
 PLEASE PROVIDE LOCATION AND DETAIL OF
 FIRE DAMPER AS REQUIRED PER 2001 FBC(M)
 607.1.2 & 607.6.
  
 2.PLAN DOES NOT INDICATE CONDENSATE
 TERMINATION, SHOW COMPLIANCE WITH 2001
 FBC(M) 307.2.1 & FBC 1503.4.4.
  
 3.DETAIL OF CONDENSING UNIT SUPPORT ON
 PLAN SHEET 7.1, CLEARANCE BETWEEN THE
 ROOF SURFACE AND THE BOTTOM OF THE
 SUPPORT RAIL SHALL COMPLY WITH 2001 FBC
 1511.7.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-12-23 Cont ID  
Sent By kstevens Date 2004-12-23 Time 16:45 Rev Time 0.62
Received By kstevens Date 2004-12-23 Time 16:45 Sent To  
Notes
2004-12-23 00:00:00PASSED/PROVISO
  
 SECTION 606.1(4)FULL OPEN VALVES
 REQUIRED

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-11-29 Cont ID  
Sent By kstevens Date 2004-11-29 Time 14:13 Rev Time 0.45
Received By kstevens Date 2004-11-29 Time 14:13 Sent To  
Notes
2004-11-29 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 1) SHT 3.1 SHOW CLEAR FLOOR SPACE FOR
 FIXTURES IN THE TOILET ROOMS, AND THE
 TURNING AREA FOR EACH ROOM. SECTIONS
 11-4.16.2, 11-4.19.3, AND 11-4.22.3
 2) SHT 8.1 SHOW THE MEASURMENT OFF THE
 WALL TO THE CENTERLINE OF THE WATER
 CLOSET AS 18 INCHES AND THE CENTERLINE
 OF THE LAV AS 15 INCHES MIN. FIGURE 28
 AND FIGURE 7(C).
 3) SHT 3-1 SHOW FORWARD APPROACH CLEAR
 FLOOR SPACE FOR THE SINK IN THE SANX
 ROOM AS REQUIRED IN SECTION 11-4.24.5.
 SUBMIT A DETAIL SHOWING COMPLIANCE WITH
 SECTIONS 11-4.24.3 KNEE CLEARANCE 27"
 HIGH, 30" WIDE, AND 19" DEEP PROVIDED
 UNDERNEATH THE SINK, 11-4.24.4 SINK
 DEPTH 6-1/2", 11-4.24.5 CLEAR FLOOR
 SPACE, AND 11-4.24.6 EXPOSED PIPES AND
 SURFACES, 11-4.24.7 FAUCETS. - PER
 BUILDING OFFICIAL, DOORS UNDER THE SINK
 ARE NOT APPROVED AS THEY CREATE AN
 OBSTRUCTION, THE SPACE UNDER SHALL BE
 CLEAR FLOOR SPACE.
 4) SHT M2 SANITARY RISER ISOMETRIC AND
 THE PLUMBING PLAN, DELETE THE CLEANOUT
 LEFT OF THE BUILDING DRAIN DOWNSTREAM OF
 THE TOILET ROOMS. IT IS NOT REQUIRED AND
 CAN CREATE A BLOCKAGE AS THE FITTING TO
 CONNECT THE CLEANOUT TO THE SYSTEM WILL
 BE AGAINST THE DIRECTION OF FLOW.
 SECTION 706.3
 5) FULL OPEN VALVES SHALL BE INSTALLED
 ON THE TOP OF EVERY WATE DOWN-FEED PIPE.
 SECTION 606.1(4)
 6) AN RPZ BACKFLOW IS REQUIRED ON THE
 WATER SERVICE. SECTION 608.13.2
 7) THERMAL EXPANSION CONTROL IS REQUIRED
 PER SECTION 607.3.2
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2004-12-07 Cont ID  
Sent By lmartine Date 2004-12-07 Time 10:37 Rev Time  
Received By lmartine Date   Time   Sent To  
Notes
***NONE***