| Plan Review Stops For Permit 04110265 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-12-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-12-22 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-12-22 |
Time |
15:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-12-06 |
Time |
16:30 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-12-06 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2004-12-06 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04110265 | | | ADD: 1710 UPLAND RD | | | CONT: ANDERSON MOORE | | | TEL: (561)662-1819 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) 11-4.24.3 KNEE CLEARENCE THAT IS AT | | | LEAST 27" HIGH 30" WIDE, AND 19" DEEP | | | SHALL BE PROVIDED UNDERNEATH SINKS. | | | | | | 3) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 4) 1503.4.4 PROTECTION AGAINST DECAY & | | | TERMITES. CONDENSATE LINES & ROOF DOWN | | | SPOUTS SHALL DISCHARGE AT LEAST 1 FT. | | | AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EX- | | | TENSIONS, OR SPLASH BLOCKS. | | | | | | 5) 1511.7 ROOF MOUNTED MECHANICAL UNIT S | | | SHALL BE MOUNTED ON CURBS RAISED A | | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. | | | MECH. 301.13 WIND RESISTANCE MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUP PORTS THAT | | | ARE EXPOSED TO WIND SHALL BE DESIGNED | | | AND INSTALLED TO RESIST THE WIND | | | PRESSURES ON THE EQUIPMENT & THE | | | SUPPORTS AS DETERMINED IN ACCORDANCE | | | WITH THE FL BLD CODE. THIS MAY BE ACCOMP | | | LISHED BY DESIGN OR BY APPLICATION OF | | | SECTION 301.13.1. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-01-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-26 |
Time |
10:44 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-01-26 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-01-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-04 |
Time |
15:30 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-01-04 |
Time |
15:30 |
Sent To |
B |
|
| Notes |
| 2005-01-04 00:00:00 | NEW PME, SIGNED BY THE ENGINEER OF | | | RECORD. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-29 |
Time |
10:36 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-12-29 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2004-12-29 00:00:00 | ************ UNSAT ************* | | | | | | PLEASE SEE NEW ELECTRICAL SHEETS | | | INSERTED INTO PREVIOUSLY STAMPED PLANS. | | | | | | | | | 1)NOTE: PLEASE SEE NOTE ON RISER HAS | | | BEEN REVISED TO HAVE EQUIPMENT GROUNDING | | | CONDUCTOR FROM MAIN DISC GROUNDED TO | | | GRND ROD, COLD WATER AND FOOTER STEEL?? | | | THIS MUST BE A MISPRINT. | | | | | | 2)NOTE: PLEASE SEE NEW SHEETS AND SETS | | | FOR P | | | SEALED BY THE ENGINEER RESPONSIBLE FOR | | | PLANS. CHANE INC ON TITLE BLOCK. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-11-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-15 |
Time |
16:30 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-11-15 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2004-11-15 00:00:00 | REDLINED SEC'S PER 310.16 | | | EXST RISER NOTES FPL, YET SEC'S ARE FROM | | | WEATHER-HEAD TO METER. | | | | | | REDLINED POSSIBLE EQUIPMENT GROUNDING | | | CONDUCTOR FROM MAIN DISC TO PANEL. | | | 250.24,250.122 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2004-12-07 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2004-12-07 |
Time |
10:37 |
Rev Time |
|
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-12-07 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-12-07 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-12-07 |
Time |
12:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-04-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-04 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-04 |
Time |
15:59 |
Sent To |
M |
|
| Notes |
| 2005-04-04 00:00:00 | TO "PKRAUSS" BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-03-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-23 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-23 |
Time |
15:07 |
Sent To |
M |
|
| Notes |
| 2005-03-23 00:00:00 | TO "M" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-21 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-21 |
Time |
11:47 |
Sent To |
E |
|
| Notes |
| 2005-01-21 00:00:00 | TO "DP" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-12-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-16 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-16 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2004-12-16 00:00:00 | SENT TO "COMM BD#17" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-12-22 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-11-05 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2004-11-05 00:00:00 | TO COMM BD#31 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-04-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-04-06 |
Time |
08:49 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-04-06 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2005-03-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-25 |
Time |
09:11 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-03-25 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2005-03-25 00:00:00 | DENIED: | | | PLANS MUST BE SIGNED AND SEALED BY THE | | | ENGINEER. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805- |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-12-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-27 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-12-27 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2004-12-27 00:00:00 | PASSED PER PAT RAFTER |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-04 |
Time |
05:51 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-12-04 |
Time |
05:49 |
Sent To |
|
|
| Notes |
| 2004-12-04 00:00:00 | DENIED: | | | 1.PLAN SHEET 3.1 & 8.1 INDICATE THE | | | SEPARATION BETWEEN THE WAREHOUSE AND THE | | | OFFICE AREA HAS A 2 HR FIRE RATING. | | | PLEASE PROVIDE LOCATION AND DETAIL OF | | | FIRE DAMPER AS REQUIRED PER 2001 FBC(M) | | | 607.1.2 & 607.6. | | | | | | 2.PLAN DOES NOT INDICATE CONDENSATE | | | TERMINATION, SHOW COMPLIANCE WITH 2001 | | | FBC(M) 307.2.1 & FBC 1503.4.4. | | | | | | 3.DETAIL OF CONDENSING UNIT SUPPORT ON | | | PLAN SHEET 7.1, CLEARANCE BETWEEN THE | | | ROOF SURFACE AND THE BOTTOM OF THE | | | SUPPORT RAIL SHALL COMPLY WITH 2001 FBC | | | 1511.7. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-23 |
Time |
16:45 |
Rev Time |
0.62 |
| Received By |
kstevens |
Date |
2004-12-23 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2004-12-23 00:00:00 | PASSED/PROVISO | | | | | | SECTION 606.1(4)FULL OPEN VALVES | | | REQUIRED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-11-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-29 |
Time |
14:13 |
Rev Time |
0.45 |
| Received By |
kstevens |
Date |
2004-11-29 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2004-11-29 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT 3.1 SHOW CLEAR FLOOR SPACE FOR | | | FIXTURES IN THE TOILET ROOMS, AND THE | | | TURNING AREA FOR EACH ROOM. SECTIONS | | | 11-4.16.2, 11-4.19.3, AND 11-4.22.3 | | | 2) SHT 8.1 SHOW THE MEASURMENT OFF THE | | | WALL TO THE CENTERLINE OF THE WATER | | | CLOSET AS 18 INCHES AND THE CENTERLINE | | | OF THE LAV AS 15 INCHES MIN. FIGURE 28 | | | AND FIGURE 7(C). | | | 3) SHT 3-1 SHOW FORWARD APPROACH CLEAR | | | FLOOR SPACE FOR THE SINK IN THE SANX | | | ROOM AS REQUIRED IN SECTION 11-4.24.5. | | | SUBMIT A DETAIL SHOWING COMPLIANCE WITH | | | SECTIONS 11-4.24.3 KNEE CLEARANCE 27" | | | HIGH, 30" WIDE, AND 19" DEEP PROVIDED | | | UNDERNEATH THE SINK, 11-4.24.4 SINK | | | DEPTH 6-1/2", 11-4.24.5 CLEAR FLOOR | | | SPACE, AND 11-4.24.6 EXPOSED PIPES AND | | | SURFACES, 11-4.24.7 FAUCETS. - PER | | | BUILDING OFFICIAL, DOORS UNDER THE SINK | | | ARE NOT APPROVED AS THEY CREATE AN | | | OBSTRUCTION, THE SPACE UNDER SHALL BE | | | CLEAR FLOOR SPACE. | | | 4) SHT M2 SANITARY RISER ISOMETRIC AND | | | THE PLUMBING PLAN, DELETE THE CLEANOUT | | | LEFT OF THE BUILDING DRAIN DOWNSTREAM OF | | | THE TOILET ROOMS. IT IS NOT REQUIRED AND | | | CAN CREATE A BLOCKAGE AS THE FITTING TO | | | CONNECT THE CLEANOUT TO THE SYSTEM WILL | | | BE AGAINST THE DIRECTION OF FLOW. | | | SECTION 706.3 | | | 5) FULL OPEN VALVES SHALL BE INSTALLED | | | ON THE TOP OF EVERY WATE DOWN-FEED PIPE. | | | SECTION 606.1(4) | | | 6) AN RPZ BACKFLOW IS REQUIRED ON THE | | | WATER SERVICE. SECTION 608.13.2 | | | 7) THERMAL EXPANSION CONTROL IS REQUIRED | | | PER SECTION 607.3.2 | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-07 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2004-12-07 |
Time |
10:37 |
Rev Time |
|
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|