Plan Review Details - Permit 04110228
| Plan Review Stops For Permit 04110228 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-08-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-14 |
Time |
06:41 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2005-08-14 |
Time |
06:33 |
Sent To |
PC |
|
| Notes |
| 2005-08-14 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04110228 | | | ADD: 516 BANYAN BLVD | | | "THE PLACE VIA CLEMATIS" | | | CONT:THE OPERIS GROUP, CORP. | | | TEL: (305)624-0245 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)YOUR RESPONCE TO THIS COMMENT IS | | | BMD/LLC, PLEASE PROVIDE THE RECORDED | | | DOCUMENT OR IF IT IS A NEW PLAT PROVIDE | | | THE PLAT. | | | THE PROPOSED BUILDING STRUCTURE | | | TRANSGRESSES LEGAL BOUNDARY LINES | | | BETWEEN THE LOTS WHICH COMBINE TO FORM | | | 'THE SITE'.A 'UNITY OF TITLE' SHALL | | | BE RECORDED AT THE COUNTY COURTHOUSE. | | | SUBMIT A COPY OF THE RECORDED 'UNITY OF | | | OF TITLE' DOCUMENT SO THAT FBC TABLE | | | 600 BOUNDARY LINE REQUIREMENTS MAY BE | | | DEEMED NOT APPLICABLE. | | | | | | 3)THIS DOCUMENT MUST BE PROVIDED AS PART | | | OF THE PERMIT PACKAGE BEFORE THE PERMIT | | | WILL BE ISSUED. FL S. S. 553.71(7) " | | | THRESHOLD BUILDING" MEANING ANY BUILDING | | | WHICH IS GREATER THAN (3) STORIES OR 50 | | | FT IN HEIGHT, OR WHICH HAS AN ASSEMBLY | | | OCCUPANCY CLASSIFICATION AS DEINED IN | | | THE FLORIDA BUILDING CODE WHICH EXCEEDS | | | 5,000 SQ FT IN AREA AND AN OCCUPANT | | | CONTENT OF GREATER THAN 500 PERSONS. | | | 105.13.1 THE ENFORCING AGENCY SHALL | | | REQUIRE A SPECIAL INSPECTOR TO PERFORM | | | SRUCTURAL INSPECTIONS ON A THRESHOLD | | | BUILDING PURSUANT TO A STRUCTURAL | | | INSPECTION PLAN PREPARED BY THE ENGINEER | | | OF RECORD. THE "STRUCTURAL INSPECTION | | | PLAN" MUST BE SUBMITTED TO THE ENFORCING | | | AGENCY PRIOR TO THE ISSUANCE OF A | | | BUILDING PERMIT FOR THE CONSTRUCTION OF | | | A THRESHOLD BUILDING. THE PURPOSE OF THE | | | SRUCTURAL INSPECTION PLAN IS TO PROVIDE | | | SPECIFIC INSPECTION PROCEDURES AND | | | SCHEDULES SO THAT THE BUILDING CAN BE | | | ADEQUATELY INSPECTED FOR COMPLIANCE WITH | | | THE PERMITTED DOCUMENTS. | | | | | | 4)RESPONCE TO THIS COMMENT IS SEE SHEET | | | 1 OF 8? AGAIN THIS DOCUMENT MUST BE PART | | | OF THE PERMIT PACKAGE BEFORE ISSUANCE OF | | | THIS PERMIT PRIOR TO THE ISSUANCE OF | | | THIS PERMIT. | | | WPB AMENDMENT 105.13.6. W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT | | | REQUEST FOR THRESHOLD BUILDINGS A | | | SPECIAL INSPECTOR AS REQUIRED BY S. | | | 553.79(5) FLORIDA STATUTES TO THE MIN- | | | IMUM INSPECTIONS REQUIRED BY THIS CODE. | | | CONTACT HAROLD PISKURA MANAGER OF THE | | | SPECIAL INSPECTOR PROGRAM AT (561) | | | 805-6711 FOR FURTHER INFORMATION BEFORE | | | THE PERMIT MAY BE ISSUED. | | | | | | 5) W.P.B. AMENDMENT 105.13.4.4 ALL | | | PLANS FOR THE BUILDING WHICH ARE | | | REQUIRED TO BE SIGNED AND SEALED BY THE | | | ARCHITECT OR ENGINEER OF RECORD CON- | | | TAIN A STATEMENT THAT, TO THE BEST OF | | | THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, | | | THE PLANS AND SPECIFICATIONS COMPLY WITH | | | THE APPLICABLE FIRE-SAFETY STANDARDS AS | | | DETERMINED BY THE LOCAL AUTHORITY IN | | | ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | THIS IS A THRESHOLD BUILDING THIS | | | STATEMENT IS TO BE ON ALL SHEETS | | | INCLUDING STRUCTURAL SHEETS. SEE | | | REQUIREMENTS FOR THE MEP DRAWINGS TO SEE | | | IF EACH OF THESE TRADES QUALIFY AS | | | THRESHOLD BUILDING, IF SO THEY ALSO MUST | | | HAVE THE SAME STATEMENT ON ALL PAGES. | | | | | | | | | 6) FBC* F102.2.7ARCHITECTURAL TRIM, | | | TRELLISES, ON BUILDINGS LOCATED IN THE | | | FIRE DISTRICT,SHALL BE CONSTRUCTED OF | | | APPROVED NON-COMBUSTIBLE MATERIALS OR | | | FIRE RETARDANT TREATED WOOD.ANNOTATE | | | THE PLANS TO DEMONSTRATE COMPLIANCE. | | | A PAINT ON THE SURFACE PRODUCT WILL NOT | | | BE ACCEEPTED BY THE BUILDING OFFICIAL. | | | | | | A NOTE WAS ADDED INDICATING TRELLISES | | | SHALL BE OF ALUMINUM BUT THE ORIGINAL | | | NOTE WOOD TRELLISES IS STILL THERE, | | | "DELETE THE WOOD TRELLIS NOTE!!"ALSO | | | DELETE THE NOTES FOR FIRE RETARDANT | | | PAINT ON WOOD TRELLISES. | | | | | | | | | | | | 7) FBC* F102.2.8PERMANENT CANOPIES/ | | | AWNINGS AND THEIR SUPPORTS, ON BUILDINGS | | | LOCATED IN THE FIRE DISTRICT, SHALL BE | | | OF NON-COMBUSTIBLE MATERIAL, FIRE | | | RETARDANT TREATED WOOD, WOOD OF TYPE | | | III SIZES OR OF 1-HOUR RESISTANT | | | CONSTRUCTION.ANNOTATE THE PLANS TO | | | DEMONSTRATE COMPLIANCE. THE BUILDING | | | OFFICIAL HAS RULED THAT A PAINT ON | | | RETARDANT WILL NOT BE ACCEPTABLE FOR | | | WOOD PRODUCTS. AGAIN DELETE ALL NOTES | | | ABOUT WOOD TRIM ON THE EXTERIOR OF THE | | | BUILDING.1404.1.1 ARCHITECTURAL TRIM ON | | | BUILDINGS OF TYPE I, II AND IV | | | CONSTRUCTION NOT MORE THAN THREE STORIES | | | OR 40 FT (12.2 M) HIGH MAY BE OFTYPE | | | VI CONSTRUCTION, THIS BUILDING IS OVER | | | 40' TALL. | | | | | | | | | 8) FBC* F102.2.4ROOF COVERINGS, ON | | | BUILDINGS LOCATED IN THE FIRE DISTRICT, | | | SHALL CONFORM TO THE REQUIREMENTS OF | | | CLASS A OR B ROOF COVERINGS, AS DEFINED | | | IN FBC 1505.ANNOTATE THE PLANS TO | | | DEMONSTRATE COMPLIANCE. THE MIAMI-DADE | | | REPORT NEOGARD WAS NOT TEST FOR FIRE | | | CLASSIFICATION. NO REPORTS WERE | | | SUBMITTED FOR ASPHALT UNDERLAYMENT OR | | | ROLL ROOFING.NO SUBMITTALS FOR THE | | | FINISH ROOF TILE. | | | | | | *** ALSO NOTE THIS IS A TYPE II | | | BUILDINGWHERE THE PLYWOOD ROOF | | | SHEATHING IS SPECIFIED ( S2.1 DETAIL | | | 4)SEE FOOTNOTE (E) TABLE 600, BUILDINGS | | | NOT OVER TWO STORIES APPROVED FIRE | | | RETARDANT TREATED WOOD MAY BE USED. | | | | | | | | | 9) THE PLANS DO NOT PROVIDE | | | INFORMATION FOR WORK TO BE COMPLETED IN | | | THE PUBLIC PROPERTY. SEE CHAPTER 33, | | | WHERE COVERED WALKWAYS WILL BE REQUIRED | | | 3304, CONSTRUCTION OF WALKWAYS, FENCES | | | AND PROTECTIVE COVERINGS. AGAIN THE NOTE | | | ONLY COVERS THE UNDERMINING OF THE RIGHT | | | OF WAY. NO PRECAUTIONS WERE TAKEN THE | | | SHEET PILE ARE NOT IN AND THE ALEY WAY | | | IS BEING ERODED AWAY, NO PRECAUTONS TO | | | DATE HAVE BEEN TAKEN. | | | | | | | | | | | | 10) CONCERNS THAT TABLE 600 ISSUES EXIST | | | SINCE THE BUILDING IS ON THE PROPERTY | | | LINE AND THE ALLEY IS ONLY 14' WIDE. | | | SINCE THE STRUCTURE IS DIRECTLY ON THE | | | PROPERTY LINE TABLE 600 ISSUES OCCUR. | | | PROVIDE DOCUMENTATION AS TO WHAT THE | | | VARIANCE WAS GRANTED FOR. | | | | | | UNTIL COPIES OF THE GRANTED VARIANCE ARE | | | RECEIVED NO COMMENT ON 10AOR B. | | | | | | | | | 10C) PROVIDE THE EQUIVALENT THICKNESS | | | REQUIRED FOR BEARING AND NONBEARING | | | CONCRETE BLOCK. SEE 709.3.1. DO NOT | | | PROVIDE A UL RATING BUT THE ACTUAL | | | EQUIVALENT THICKNESS FROM THE BLOCK | | | MANUFACTURE FOR2HR, 3 HR & 4HR WALLS. | | | | | | | | | | | | 11 SEE DOOR SCHEDULE A.35 IS MISSING | | | PROTECTION OF OPENINGS IN INTERIOR | | | WALLS,( 705.1.2) SEE TABLE 705.1.2 FOR | | | THE REQUIRED RATINGS.PLANS INDICATE THIS | | | TO BE A LOUVERED DOOR, PLANS ONLY | | | INDICATE FIRE RATED NO RATING, INDICATE | | | HOW RATING WILL BE ACHIEVED ON A | | | LOUVERED DOOR. | | | | | | | | | 12) ADDITIONAL INFORMATION REQUIRED, | | | PLANS HAVE A COMMENT STATING "A SEPERATE | | | PERMIT REQUIRED", SHEET A35 FOR WINDOWS | | | AND DOORS. PRODUCT APPROVALS HAVE BEEN | | | SUBMITTED, WHAT ISN'T CLEAR IS IF THESE | | | SUBMITTALS ARE TO BE PART OF THIS | | | PERMIT. | | | ****SINCE THE LAST REVIEW THE BUILDING | | | OFFICIAL HAS MADE ME AWARE THAT FOR AN | | | ENCLOSED BUILDING WE SHALL HAVE ALL THE | | | INFORMATION REQUIRED ( WINDOWS, DOORS | | | AND ASSOCIATED ROOFING COMPONENTS) | | | BEFORE A PERMIT TO START CONSTRUCTION | | | SHALL BE ISSUED.**** | | | | | | 12A) THE DOORS OR WINDOWS THAT FACE THE | | | SOUTH THAT ARE WITHIN 15' OF THE | | | PROPERTY LINE WILL REQUIRE OPENING | | | PROTECTIVES. ONCE IN RECEIPT OF THE | | | VARIANCE THIS MAY BE RESOLVED. | | | | | | 12B) 1606.1.4(1) IN WIND BORNE DEBRIS | | | REGIONS, EXTERIOR GLAZING THAT RECEIVES | | | POSITIVE PRESSURE IN BUILDINGS SHALL BE | | | ASSUMED TO BE OPENINGS UNLESS SUCH | | | GLAZING IS IMPACT RESISTANT OR | | | PROTECTED WITH AN IMPACT RESISTANT | | | COVERING MEETING THE REQUIREMENTS OF | | | SSTD 12, ASTM E 1886 AND ASTM E 1996 OR | | | MIAMI-DADE. | | | 1) GLAZED OPENINGS LOCATED WITHIN 30 | | | FT | | | OF GRADE SHALL MEET THE REQUIREMENTS OF | | | LARGE MISSLE TEST.SEE COPY OF CITY OF | | | W.P.B. INTERPRETATION OF HURRICANE | | | STANDARDS FOR LARGE PROJECTS. | | | | | | 12C) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE | | | AT WWW.FLORIDABUILDING.ORG. PRODUCTS | | | WITH STATEWIDE APPROVAL ARE REQUIRED TO | | | BE SUBMITTED WITH A COVER SHEET THAT | | | LISTS THE PRODUCT IDENTITY NUMBER FROM | | | THE STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 13)FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS- FIXED OR OPERATABLE | | | B) PANELWALL-STOREFRONT | | | C) GLAZED EXTERIOR DOORS | | | D) SOLID EXTERIOR DOORS | | | E) MULLIONS | | | F) VENTS/ LOUVERS | | | G) STRUCTURAL COMPONENTS- TRUSS | | | ANCHORS | | | CONCRETE ADMIXTURES, RAILINGS | | | H) ROOFING PRODUCTS- AND INSULATION. | | | THE ABOVE IS MENTIONED AS TO | | | REQUIREMENTS TO OBTAIN A BUILDING | | | PERMIT. THE NOTES FOUND ON A.35 NOTE | | | FOR WINDOWS AND STOREFRONT ARE TO BE | | | UNDER A SEPERATE PERMIT. | | | ****SINCE THE LAST REVIEW THE | | | BUILDING OFFICIAL HAS MADE ME AWARE THAT | | | FOR AN ENCLOSED BUILDING WE SHALL HAVE | | | ALL THE | | | INFORMATION REQUIRED ( WINDOWS, DOORS | | | AND ASSOCIATED ROOFING COMPONENTS) | | | BEFORE A PERMIT TO START CONSTRUCTION | | | SHALL BE ISSUED.**** | | | | | | 14) THE 4 GARAGE OPENINGS ON THE SOUTH | | | SIDE OF THE BUILDING DO NOT PROVIDE THE | | | PRESSURES (POS/NEG) ASSSOCIATED WITH THE | | | BUILDING? 1606.6/ ASCE 7-98. THE GARAGE | | | DOOR REPORTS MAY OR MAY NOT WORK BECAUSE | | | OF LOW PRESSURES?NO FL COVERSHEET MAY | | | ALSO REQUIRE A LOCAL PRODUCT APPROVAL. | | | THIS MAY ALSO CHANGE ON THE RESULTS | | | OF THE VARIANCE, ORIGINALLY A CHAINED | | | TYPE GATE OF GARAGE DOOR WAS CONSIDERED. | | | IF NOT USING THE GARAGE DOOR REMOVE FROM | | | PACKAGE, THE SAME WITH THE FIRELITE | | | GLASS. | | | | | | 15) THE WINDOW REPORTS SUBMITTED HAVE | | | MULTIPLE TYPES OF GLAZING THAT MAY BE | | | USED, HIGHLIGHT OR INDICATE THE SYSTEM | | | USED, ALSO LOOK AT THE HEIGHT/WIDTH AND | | | PRESSURES, END ZONES -123, WILL THERE BE | | | ONE TYPE OF GLAZING FOR END ZONES AND | | | ANOTHER FOR INTERIOR ZONES IF SO | | | INDICATE? | | | | | | 16) THE R C ALUMINIUM REPORT SUBMITTED | | | IS FOR LARGE MISSLE TESTING ONLY NOT | | | TESTED FOR PRESSURES. | | | A) 2400 ST SLIDING GLASS DOOR | | | B) "FX-345" IF IN END ZONE WILL NOT MEET | | | THE REQUIRED -123.8 | | | C) RD 45 ONLY GOOD FOR +- 80 WILL NOT | | | MEET END ZONES | | | D) STEELCRAFT OUTSWING +- 65 LOW | | | PRESSURE FOR INTERIOR ZONES + END ZONES. | | | | | | | | | 17) THE R C ALUMINIUM ENTRY DOOR LMI | | | INDICATES MAXIMUM DESIGN PRESSURES GOOD | | | FOR +/- 80, BUT END ZONES INDICATE -123. | | | | | | 18) STEELCRAFT DOORS INDICATES MAXIMUM | | | DESIGN PRESSURE OF +- 65 THESE DOORS | | | WILL BE USED ON THE ROOF TOP WHERE THE | | | PRESSURES WILL BE -123. | | | | | | 19) ON THE ROOF TOP DECK THE RESTROOMS | | | ARE USING INTERIOR DOORS, DOOR# 15 IS A | | | INTERIOR DOOR. | | | NOTE NO OTHER PRODUCT APPROVALS WERE | | | SUBMITTED. | | | | | | 20) A-37 DETAILS 6 & 7, SOFFITS, DROP | | | CEILINGS, OR TRAY CEILINGS ALL INDICATE | | | THE SAME PHRASE," TO BE PROPERLY | | | ANCHORED TO THEUNDERSIDE OF STRUCTURE" | | | BUT THE DESIGN TEAM LACKS INDICATING HOW | | | TO ACHIEVE THIS TASK? | | | 104.2.1 W.P.B. ADMINISTRATIVE CODE | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN | | | INFORMATION, IN THE FORM OF NOTES OR | | | OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | | CONFORMITY WITH THE TECHNICAL CODES. | | | SUCH INFORMATION SHALL BE SPECIFIC AND | | | THE TECHNICAL CODES "SHALL NOT BE CITED | | | AS A WHOLE OR IN PART, NOR THE TERM | | | "LEGAL" OR ITS RQUIVALENT BE USED AS A | | | SUBSTITUTE FOR SPECIFIC INFORMATION". | | | | | | 21) TYPE II CONSTRUCTION 604 REQUIRES | | | STRUCTURAL MEMBERS TO BE NON | | | COMBUSTIBLE. | | | A.15 WOOD TRELLIS EIGHTHFLOOR TO BE | | | NONCOMBUSTIBLE,1404.1.1 ARCHITECTURAL | | | TRIM ON BUILDINGS OF TYPE I, II AND IV | | | CONSTRUCTION NOT MORE THAN THREE | | | STORIES OR 40 FT (12.2 M) HIGH MAY BE OF | | | TYPE VI CONSTRUCTION.THIS BUILDINGS MEAN | | | ROOF THEIGHT IS 90FT. | | | A.20 THE POOL HOUSE, STAIR AND | | | ELEVATION SHEETS INDICATE WOOD RAFTERS. | | | A.24 WALL SECTIONS A&D INDICATE THE USE | | | OF 5/8" CDX PLYWOOD FOR ROOF SHEATHING. | | | ALSO 2X6 WOOD FACIA OVER 1X8????? | | | TYPE II CONSTRUCTION, TABLE 600 ROOFS TO | | | BE 1HR PROTECTED, NONCOMBUSTIBLE. | | | | | | 22) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | FOR THE POOL HOUSE AND ASSOCIATED | | | STRUCTURES ATOP THE BUILDING, NO | | | INFORMATION WAS SUBMITTED TO BE ABLE TO | | | DO A THROUGH PLAN REVIEW!!!!!!!! ROOF | | | FRAMING PACKAGE FOR POOL DECK | | | STRUCTURES. THE ONLY ITEM THE POOL | | | CONTRACTOR WILL BE PERMITING IS THE | | | PLUMBING AND ELECTRICAL.STRUCTURAL | | | DETAILS FOR THIS DECK TO BE PART OF THE | | | STRUCTURAL PLANS. | | | | | | S-1.7A/S-1.7B POOL DECK PLANS DO NOT | | | INDICATE STRUCTURAL DETAILS FOR THE | | | STRUCTURESLOCATED ON THIS FLOOR, PLANS | | | INDICATE LIGHT GAUGE STEEL TRUSSES. THE | | | ENGINEER OF RECORD TO DESIGN THE | | | MAGNITUDE OF LOADS ARE TO BE RESISTED, | | | UPLIFT, GRAVITY AND LATERAL LOADS.ALSO R | | | THE COLUMN FRAMING FOR THE BREEZEWAYS. | | | 1606.1.3 ANCHORAGE AGAINST | | | OVERTURNING, UPLIFT AND SLIDING. | | | STRUCTURALMEMBERS AND SYSTEMS, AND | | | COMPONENTS AND CLADDING IN A BUILDING OR | | | STRUCTURE SHALL BE ANCHORED TO RESIST | | | WIND-INDUCED OVERTURNING, UPLIFTAND | | | SLIDING AND TO PROVIDE CONTINUOUS LOAD | | | PATHS FOR THESE FORCES TO THE | | | FOUNDATION.WHERE A PORTION OF THE | | | RESISTANCE TO THESE FORCES IS PROVIDED | | | BY DEAD LOAD, THE MINIMUM DEAD LOAD | | | LIKELY TO BE IN PLACE DURING A DESIGN | | | WIND EVENT SHALL BE USED. | | | | | | 23) STAIRWELLS INDICATE HOW PLANS ARE TO | | | COMPLY WITH 11-4..4.2 HEADROOM.THIS | | | SECTION OF THE CODE DEALS WITH THE BLIND | | | ON THE BOTTOM OF THE STAIRWELL WALKING | | | IN UNDERNEATH THE STAIRS AND CAUSING | | | INJURY TO THEIR HEAD BECAUSE THIS AREA | | | BENEATH THE STAIRWAY WAS NOT ENCLOSED OR | | | BLOCKED OFF. | | | SEE THIS SECTION OF THE CODE WHAT IS | | | REQUIRED!!!!!!!! | | | | | | 24) SHOW COMPLIANCE WITH 412.5 SMOKE | | | CONTROL, M-16 SMOKE ZONE CONTROLS/ ZONE | | | II, PLANS INDICATE THE USE OF | | | PRESSURIZATION, THIS STILL DOESN'T | | | REMOVE SMOKE, SEE 412.5. | | | | | | 25) COMMEENT # 28 FROM THE PEVIOUS | | | REVIEW: | | | BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 25) COMMEENT# 29 FROM THE PREVIOUS | | | REVIEW, PLEASE PULL THE ARCHITECTURAL | | | AND STRUCTURAL SHEETS OUT TO FORM THERE | | | OWN ROLL | | | ** TO DATE THIS HAS NOT BEEN COMPLETED** | | | | | | 26) TO EXPEDITE REVIEW OF A RESUBMITTAL | | | WHICH REQUIRES NEW PLANS IN ORDER TO | | | ADDRESS THE ABOVE COMMENTS, THE OLD | | | SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHOULD BE STAPLED/CLIPPED TO THE | | | REMAINING OLD SHEETS, TO FORM A SET OF | | | 'OLD/VOID SHEETS', FOR COMPARISON OF | | | REVISIONS WHEN REVIEWING THE RESUBMITTED | | | PLANS. | | | ***************TO DATE THIS HAS NOT BEEN | | | COMPLETED, NONE OF THE OLD REVISED PLANS | | | HAVE BEEN SUBMITTED******************** | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-04-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-04-07 |
Time |
08:26 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2005-04-07 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2005-04-07 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04110228 | | | ADD: TO BE DECIDED | | | "THE PLACE VIA CLEMATIS" | | | CONT:PLAN REVIEW | | | CONTACT: BLUE MOON DEV | | | TEL: (786)554-0900 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) THE PROPOSED BUILDING STRUCTURE | | | TRANSGRESSES LEGAL BOUNDARY LINES | | | BETWEEN THE LOTS WHICH COMBINE TO FORM | | | 'THE SITE'.A 'UNITY OF TITLE' SHALL | | | BE RECORDED AT THE COUNTY COURTHOUSE. | | | SUBMIT A COPY OF THE RECORDED 'UNITY OF | | | OF TITLE' DOCUMENT SO THAT FBC TABLE | | | 600 BOUNDARY LINE REQUIREMENTS MAY BE | | | DEEMED NOT APPLICABLE. | | | | | | 3) FL S. S. 553.71(7) " THRESHOLD | | | BUILDING" MEANING ANY BUILDING WHICH IS | | | GREATER THAN (3) STORIES OR 50 FT IN | | | HEIGHT, OR WHICH HAS AN ASSEMBLY | | | OCCUPANCY CLASSIFICATION AS DEINED IN | | | THE FLORIDA BUILDING CODE WHICH EXCEEDS | | | 5,000 SQ FT IN AREA AND AN OCCUPANT | | | CONTENT OF GREATER THAN 500 PERSONS. | | | 105.13.1 THE ENFORCING AGENCY SHALL | | | REQUIRE A SPECIAL INSPECTOR TO PERFORM | | | SRUCTURAL INSPECTIONS ON A THRESHOLD | | | BUILDING PURSUANT TO A STRUCTURAL | | | INSPECTION PLAN PREPARED BY THE ENGINEER | | | OF RECORD. THE STRUCTURAL INSPECTION | | | PLAN MUST BE SUBMITTED TO THE ENFORCING | | | AGENCY PRIOR TO THE ISSUANCE OF A | | | BUILDING PERMIT FOR THE CONSTRUCTION OF | | | A THRESHOLD BUILDING. THE PURPOSE OF THE | | | SRUCTURAL INSPECTION PLAN IS TO PROVIDE | | | SPECIFIC INSPECTION PROCEDURES AND | | | SCHEDULES SO THAT THE BUILDING CAN BE | | | ADEQUATELY INSPECTED FOR COMPLIANCE WITH | | | THE PERMITTED DOCUMENTS. | | | | | | 4) WPB AMENDMENT 105.13.6. W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT | | | REQUEST FOR THRESHOLD BUILDINGS A | | | SPECIAL INSPECTOR AS REQUIRED BY S. | | | 553.79(5) FLORIDA STATUTES TO THE MIN- | | | IMUM INSPECTIONS REQUIRED BY THIS CODE. | | | CONTACT HAROLD PISKURA MANAGER OF THE | | | SPECIAL INSPECTOR PROGRAM AT (561) | | | 805-6711 FOR FURTHER INFORMATION BEFORE | | | THE PERMIT MAY BE ISSUED. | | | | | | 5) W.P.B. AMENDMENT 105.13.4.4 ALL | | | PLANS FOR THE BUILDING WHICH ARE | | | REQUIRED TO BE SIGNED AND SEALED BY THE | | | ARCHITECT OR ENGINEER OF RECORD CON- | | | TAIN A STATEMENT THAT, TO THE BEST OF | | | THE ARCHITECT'S PRENGINEER'S KNOWLEDGE, | | | THE PLANS AND SPECIFICATIONS COMPLY WITH | | | THE APPLICABLE FIRE-SAFETY STANDARDS AS | | | DETERMINED BY THE LOCAL AUTHORITY IN | | | ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | 6) FBC* F102.2.7ARCHITECTURAL TRIM, | | | TRELLISES, ON BUILDINGS LOCATED IN THE | | | FIRE DISTRICT,SHALL BE CONSTRUCTED OF | | | APPROVED NON-COMBUSTIBLE MATERIALS OR | | | FIRE RETARDANT TREATED WOOD.ANNOTATE | | | THE PLANS TO DEMONSTRATE COMPLIANCE. | | | A PAINT ON THE SURFACE PRODUCT WILL NOT | | | BE ACCEEPTED BY THE BUILDING OFFICIAL. | | | | | | 7) FBC* F102.2.8PERMANENT CANOPIES/ | | | AWNINGS AND THEIR SUPPORTS, ON BUILDINGS | | | LOCATED IN THE FIRE DISTRICT, SHALL BE | | | OF NON-COMBUSTIBLE MATERIAL, FIRE | | | RETARDANT TREATED WOOD, WOOD OF TYPE | | | III SIZES OR OF 1-HOUR RESISTANT | | | CONSTRUCTION.ANNOTATE THE PLANS TO | | | DEMONSTRATE COMPLIANCE. THE BUILDING | | | OFFICIAL HAS RULED THAT A PAINT ON | | | RETARDANT WILL NOT BE ACCEPTABLE FOR | | | WOOD PRODUCTS. | | | | | | 8) FBC* F102.2.4ROOF COVERINGS, ON | | | BUILDINGS LOCATED IN THE FIRE DISTRICT, | | | SHALL CONFORM TO THE REQUIREMENTS OF | | | CLASS A OR B ROOF COVERINGS, AS DEFINED | | | IN FBC 1505.ANNOTATE THE PLANS TO | | | DEMONSTRATE COMPLIANCE. THE MIAMI-DADE | | | REPORT NEOGARD WAS NOT TEST FOR FIRE | | | CLASSIFICATION. NO REPORTS WERE | | | SUBMITTED FOR ASPHALT UNDERLAYMENT OR | | | ROLL ROOFING. | | | *** ALSO NOTE THIS IS A TYPE II | | | BUILDINGWHERE THE PLYWOOD ROOF | | | SHEATHING IS SPECIFIED ( S2.1 DETAIL | | | 4)SEE FOOTNOTE (E) TABLE 600, BUILDINGS | | | NOT OVER TWO STORIES APPROVED FIRE | | | RETARDANT TREATED WOOD MAY BE USED. | | | | | | | | | 9) THE PLANS DO NOT PROVIDE | | | INFORMATION FOR WORK TO BE COMPLETED IN | | | THE PUBLIC PROPERTY. SEE CHAPTER 33, | | | WHERE COVERED WALKWAYS WILL BE REQUIRED | | | 3304, CONSTRUCTION OF WALKWAYS, FENCES | | | AND PROTECTIVE COVERINGS. | | | | | | 10) CONCERNS THAT TABLE 600 ISSUES EXIST | | | SINCE THE | | | BUILDING IS ON THE PROPERTY LINE AND | | | THE ALLEY IS ONLY 14' WIDE. SINCE THE | | | STRUCTURE IS DIRECTLY ON THE PROPERTY | | | LINE TABLE 600 ISSUES OCCUR. | | | | | | 10A) THE WALL SECTION THAT IS 6'-0" | | | AWAY FROM THE PROPERTY LINE, THAT | | | CONTAINS THE OPENING FOR THE RAMPED | | | DRIVE CAN ONLY HAVE 20% OPENINGS & | | | REQUIRES A 3 HR WALL. 1/2 OF THE ALLEY | | | OR 7'+6'= 13' OR 20% ALLOWABLE OPENINGS, | | | PER FLOOR!SEE 705.1.1.2 FOR OPENINGS | | | LESS THAN 15' FROM THE PROPERTY LINE. | | | | | | 10B) THE WALL SECTIONS THAT ARE JUST TO | | | THE EASTARE RIGHT ON THE PROPERTY LINE | | | (0'-3') CAN'T HAVE ALLOWABLE OPENINGS | | | AND REQUIRE A 4 HR WALL. PLANS INDICATE | | | OPENINGS ALLOWING ENTRY TO THE ENCLOSED | | | GARAGE WITH A ROLL-UP ELECTTRIC GATE. | | | IN BOTH CASES 14(A( & (B) THE APPLICANT | | | IS GOING BEFORE THE CBAA FOR A VARIANCE | | | THE HEARING TO BE APRIL 21/2005.WILL | | | AWAIT OUTCOME OF HEARING! | | | | | | 10C) PROVIDE THE EQUIVALENT THICKNESS | | | REQUIRED FOR BEARING AND NONBEARING | | | CONCRETE BLOCK. SEE 709.3.1. DO NOT | | | PROVIDE A UL RATING BUT THE ACTUAL | | | EQUIVALENT THICKNESS FROM THE BLOCK | | | MANUFACTURE FOR2HR, 3 HR & 4HR WALLS. | | | | | | | | | | | | 11 SEE DOOR SCHEDULE A.35 IS MISSING | | | PROTECTION OF OPENINGS IN INTERIOR | | | WALLS,( 705.1.2) SEE TABLE 705.1.2 FOR | | | THE REQUIRED RATINGS. | | | A)MISSING THE RATING FOR STAIRTOWER | | | DOORS, NOT LISTED IN COMMENTS. | | | | | | 12) ADDITIONAL INFORMATION REQUIRED, | | | PLANS HAVE A COMMENT STATING "A SEPERATE | | | PERMIT REQUIRED", SHEET A35 FOR WINDOWS | | | AND DOORS. PRODUCT APPROVALS HAVE BEEN | | | SUBMITTED, WHAT ISN'T CLEAR IS IF THESE | | | SUBMITTALS ARE TO BE PART OF THIS | | | PERMIT. | | | | | | 12A) THE SECOND ISSUE SUBMITTALS FOR | | | FIRELITE GLAZING BUT IT DOES NOT SHOW UP | | | IN THE DOOR OR WINDOW SCHEDULE. | | | | | | 12B) THE DOORS OR WINDOWS THAT FACE THE | | | SOUTH THAT ARE WITHIN 15' OF THE | | | PROPERTY LINE WILL REQUIRE OPENING | | | PROTECTIVES. INDICATE IN THE DOOR AND | | | WINDOW SCHEDULES WHICH OPENINGS ARE | | | EFFECTED. ALSO IF FIRE LITE IS TO BE | | | USED HOW ARE THE REQUIREMENTS FOR LARGE | | | AND SMALL MISSLE TESSTING BEING MET? | | | | | | 12C) 1606.1.4(1) IN WIND BORNE DEBRIS | | | REGIONS, EXTERIOR GLAZING THAT RECEIVES | | | POSITIVE PRESSURE IN BUILDINGS SHALL BE | | | ASSUMED TO BE OPENINGS UNLESS SUCH | | | GLAZING IS IMPACT RESISTANT OR | | | PROTECTED WITH AN IMPACT RESISTANT | | | COVERING MEETING THE REQUIREMENTS OF | | | SSTD 12, ASTM E 1886 AND ASTM E 1996 OR | | | MIAMI-DADE. | | | 1) GLAZED OPENINGS LOCATED WITHIN 30 | | | FT | | | OF GRADE SHALL MEET THE REQUIREMENTS OF | | | LARGE MISSLE TEST.SEE COPY OF CITY OF | | | W.P.B. INTERPRETATION OF HURRICANE | | | STANDARDS FOR LARGE PROJECTS. | | | | | | 12D) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE | | | AT WWW.FLORIDABUILDING.ORG. PRODUCTS | | | WITH STATEWIDE APPROVAL ARE REQUIRED TO | | | BE SUBMITTED WITH A COVER SHEET THAT | | | LISTS THE PRODUCT IDENTITY NUMBER FROM | | | THE STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 13)FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS- FIXED OR OPERATABLE | | | B) PANELWALL-STOREFRONT | | | C) GLAZED EXTERIOR DOORS | | | D) SOLID EXTERIOR DOORS | | | E) MULLIONS | | | F) VENTS | | | G) STRUCTURAL COMPONENTS- TRUSS | | | ANCHORS | | | CONCRETE ADMIXTURES, RAILINGS | | | H) ROOFING PRODUCTS- AND INSULATION. | | | THE ABOVE IS MENTIONED AS TO | | | REQUIREMENTS TO OBTAIN A BUILDING | | | PERMIT. THE NOTES FOUND ON A.35 NOTE | | | FOR WINDOWS AND STOREFRONT ARE TO BE | | | UNDER A SEPERATE PERMIT. AT WHAT TIME | | | WILL THESE ITEMS BE ADDRESSED? SHOULD | | | THE BUILDING BE CLASSIFIED AS OPEN OR | | | PARTIALLY OPEN SINCE NO TIME FACTOR IS | | | MENTIONED TO WHEN THEY WILL BE | | | INSTALLED? | | | | | | 14) THE 4 GARAGE OPENINGS ON THE SOUTH | | | SIDE OF THE BUILDING DO NOT PROVIDE THE | | | PRESSURES (POS/NEG) ASSSOCIATED WITH THE | | | BUILDING? 1606.6/ ASCE 7-98. THE GARAGE | | | DOOR REPORTS MAY OR MAY NOT WORK BECAUSE | | | OF LOW PRESSURES?NO FL COVERSHEET MAY | | | ALSO REQUIRE A LOCAL PRODUCT APPROVAL. | | | | | | 15) THE WINDOW REPORTS SUBMITTED HAVE | | | MULTIPLE TYPES OF GLAZING THAT MAY BE | | | USED, HIGHLIGHT OR INDICATE THE SYSTEM | | | USED, ALSO LOOK AT THE HEIGHT/WIDTH AND | | | PRESSURES, END ZONES -123, WILL THERE BE | | | ONE TYPE OF GLAZING FOR END ZONES AND | | | ANOTHER FOR INTERIOR ZONES IF SO | | | INDICATE? | | | | | | 16) THE R C ALUMINIUM REPORT SUBMITTED | | | IS FOR LARGE MISSLE TESTING ONLY NOT | | | TESTED FOR PRESSURES. | | | | | | 17) THE R C ALUMINIUM ENTRY DOOR LMI | | | INDICATES MAXIMUM DESIGN PRESSURES GOOD | | | FOR +/- 80, BUT END ZONES INDICATE -123. | | | | | | 18) STEELCRAFT DOORS INDICATES MAXIMUM | | | DESIGN PRESSURE OF +- 65 THESE DOORS | | | WILL BE USED ON THE ROOF TOP WHERE THE | | | PRESSURES WILL BE -123. | | | | | | 19) ON THE ROOF TOP DECK THE RESTROOMS | | | ARE USING INTERIOR DOORS, DOOR# 15 IS A | | | INTERIOR DOOR. | | | NOTE NO OTHER PRODUCT APPROVALS WERE | | | SUBMITTED. | | | | | | 20) A-37 DETAILS 6 & 7, SOFFITS, DROP | | | CEILINGS, OR TRAY CEILINGS ALL INDICATE | | | THE SAME PHRASE," TO BE PROPERLY | | | ANCHORED TO THEUNDERSIDE OF STRUCTURE" | | | BUT THE DESIGN TEAM LACKS INDICATING HOW | | | TO ACHIEVE THIS TASK? | | | 104.2.1 W.P.B. ADMINISTRATIVE CODE | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN | | | INFORMATION, IN THE FORM OF NOTES OR | | | OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | | CONFORMITY WITH THE TECHNICAL CODES. | | | SUCH INFORMATION SHALL BE SPECIFIC AND | | | THE TECHNICAL CODES "SHALL NOT BE CITED | | | AS A WHOLE OR IN PART, NOR THE TERM | | | "LEGAL" OR ITS RQUIVALENT BE USED AS A | | | SUBSTITUTE FOR SPECIFIC INFORMATION". | | | | | | 21) TYPE II CONSTRUCTION 604 REQUIRES | | | STRUCTURAL MEMBERS TO BE NON | | | COMBUSTIBLE. | | | A.15 WOOD TRELLIS EIGHTHFLOOR TO BE | | | NONCOMBUSTIBLE, F102.2.7 FIRE DISTRICT | | | A.20 THE POOL HOUSE, STAIR AND | | | ELEVATION | | | SHEETS INDICATE WOOD RAFTERS. | | | A.24 WALL SECTIONS A&D INDICATE THE USE | | | OF 5/8" CDX PLYWOOD FOR ROOF SHEATHING. | | | ALSO 2X6 WOOD FACIA OVER 1X8????? | | | | | | 22) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | FOR THE POOL HOUSE AND ASSOCIATED | | | STRUCTURES ATOP THE BUILDING, NO | | | INFORMATION WAS SUBMITTED TO BE ABLE TO | | | DO A THROUGH PLAN REVIEW!!!!!!!! | | | S-1.6A/S-1.6B POOL DECK PLANS DO NOT | | | INDICATE STRUCTURAL DETAILS FOR THE POOL | | | STRUCTURE, SPA NOR THE COLUMN FRAMING | | | FOR THE BREEZEWAYS. | | | | | | 23) STAIRWELLS INDICATE HOW PLANS ARE TO | | | COMPLY WITH 11-4..4.2 HEADROOM.THIS | | | SECTION OF THE CODE DEALS WITH THE BLIND | | | | | | ON THE BOTTOM OF THE STAIRWELL WALKING | | | IN UNDERNEATH THE STAIRS AND CAUSING | | | INJURY TO THEIR HEAD BECAUSE THIS AREA | | | BENEATH THE STAIRWAY WAS NOT ENCLOSED OR | | | BLOCKED OFF. | | | | | | 24) SHOW COMPLIANCE WITH 412.5 SMOKE | | | CONTROL, M-16 SMOKE ZONE CONTROLS/ ZONE | | | II, PLANS INDICATE THE USE OF | | | PRESSURIZATION, THIS STILL DOESN'T | | | REMOVE SMOKE, SEE 412.5. | | | | | | 25) A-7 AUTO RAMP TO THE MEZZANINE FLOOR | | | PLAN INDICATES OPENSIDED RAMP, PROVIDE | | | INFORMATION FOR COMPLIANCE WITH | | | 1608.2.3. PARKING GAURDRAILS, IMPACT | | | GAURDRAILS, AND BOLLARDS. | | | | | | 26) A-8 PROVIDE FLOOR SLOPES AT THE | | | HANDICAPED PARKING AT THE EAST END OF | | | THE BLDG. DRAINAGE GRATE IN THE MIDDLE | | | OF THE HANDICAPPED SPACE? | | | | | | 27) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | A-9/A-10 NO INFORMATION IS PROVIDED FOR | | | WALLS AND GATES OF PRIVATE LANAI? | | | | | | 28)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 29) PLEASE PULL THE ARCHITECTURAL AND | | | STRUCTURAL SHEETS OUT TO FORM THERE OWN | | | ROLL. | | | | | | 30) SHEET S4.2THE FOUNDATION SCHEDULE | | | IS BLANK. | | | | | | 31) TO EXPEDITE REVIEW OF A RESUBMITTAL | | | WHICH REQUIRES NEW PLANS IN ORDER TO | | | ADDRESS THE ABOVE COMMENTS, THE OLD | | | SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHOULD BE STAPLED/CLIPPED TO THE | | | REMAINING OLD SHEETS, TO FORM A SET OF | | | 'OLD/VOID SHEETS', FOR COMPARISON OF | | | REVISIONS WHEN REVIEWING THE RESUBMITTED | | | PLANS. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-12-02 |
Time |
16:15 |
Rev Time |
24.00 |
| Received By |
jwitmer |
Date |
2004-12-02 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2004-12-02 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04110228 | | | ADD: TO BE DECIDED | | | "THE PLACE VIA CLEMATIS" | | | CONT:PLAN REVIEW | | | CONTACT: BLUE MOON DEV | | | TEL: (786)554-0900 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT | | | NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR | | | SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) THE PROPOSED BUILDING STRUCTURE | | | TRANSGRESSES LEGAL BOUNDARY LINES | | | BETWEEN THE LOTS WHICH COMBINE TO FORM | | | 'THE SITE'.A 'UNITY OF TITLE' SHALL | | | BE | | | RECORDED AT THE COUNTY COURTHOUSE. | | | SUBMIT A COPY OF THE RECORDED 'UNITY OF | | | OF TITLE' DOCUMENT SO THAT FBC TABLE | | | 600 | | | BOUNDARY LINE REQUIREMENTS MAY BE | | | DEEMED | | | NOT APPLICABLE. | | | | | | 3)FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITLY KNOWN OR IS IN | | | QUESTION | | | THE BUILDING OFFICIAL MAY REQUIRE | | | EXPLOR | | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | | TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA.SUPPLY (3) REPORTS. | | | | | | 4) FL S. S. 553.71(7) " THRESHOLD | | | BUILDING" MEANING ANY BUILDING WHICH IS | | | GREATER THAN (3) STORIES OR 50 FT IN | | | HEIGHT, OR WHICH HAS AN ASSEMBLY | | | OCCUPAN | | | CY CLASSIFICATION AS DEINED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS | | | 5,000 SQ FT IN AREA AND AN OCCUPANT | | | CONTENT OF GREATER THAN 500 PERSONS. | | | 105.13.1 THE ENFORCING AGENCY SHALL | | | REQUIRE A SPECIAL INSPECTOR TO PERFORM | | | SRUCTURAL INSPECTIONS ON A THRESHOLD | | | BUILDING PURSUANT TO A STRUCTURAL | | | INSPEC | | | TION PLAN PREPARED BY THE ENGINEER OF | | | RECORD. THE STRUCTURAL INSPECTION PLAN | | | MUST BE SUBMITTED TO THE ENFORCING | | | AGEN- | | | CY PRIOR TO THE ISSUANCE OF A BUILDING | | | PERMIT FOR THE CONSTRUCTION OF A | | | THRESH- | | | OLD BUILDING. THE PURPOSE OF THE | | | SRUCTUR | | | AL INSPECTION PLAN IS TO PROVIDE | | | SPECIF- | | | IC INSPECTION PROCEDURES AND SCHEDULES | | | SO THAT THE BUILDING CAN BE ADEQUATELY | | | INSPECTED FOR COMPLIANCE WITH THE | | | PERMITTED DOCUMENTS. | | | | | | 5) WPB AMENDMENT 105.13.6. W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT | | | REQUEST FOR THRESHOLD BUILDINGS A | | | SPECIAL INSPECTOR AS REQUIRED BY S. | | | 553.79(5) FLORIDA STATUTES TO THE MIN- | | | IMUM INSPECTIONS REQUIRED BY THIS CODE. | | | CONTACT HAROLD PISKURA MANAGER OF THE | | | SPECIAL INSPECTOR PROGRAM AT (561) | | | 805-6711 FOR FURTHER INFORMATION BEFORE | | | THE PERMIT MAY BE ISSUED. | | | | | | 6) W.P.B. AMENDMENT 105.13.4.4 ALL | | | PLANS | | | FOR THE BUILDING WHICH ARE REQUIRED TO | | | BE SIGNED AND SEALED BY THE ARCHITECT | | | OR | | | ENGINEER OF RECORD CON- TAIN A | | | STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT'S PR | | | ENGINEER'S KNOWLEDGE, THE PLANS AND | | | SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE FIRE-SAFETY STANDARDS AS | | | DETERMINED BY THE LOCAL AUTHORITY IN | | | ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | 7) FBC* F102.2.7ARCHITECTURAL TRIM, | | | ON | | | BUILDINGS LOCATED IN THE FIRE DISTRICT, | | | SHALL BE CONSTRUCTED OF APPROVED | | | NON-COMBUSTIBLE MATERIALS OR FIRE | | | RETARDANT TREATED WOOD.ANNOTATE THE | | | PLANS TO DEMONSTRATE COMPLIANCE. | | | | | | 8) FBC* F102.2.8PERMANENT CANOPIES/ | | | AWNINGS AND THEIR SUPPORTS, ON | | | BUILDINGS | | | LOCATED IN THE FIRE DISTRICT, SHALL BE | | | OF NON-COMBUSTIBLE MATERIAL, FIRE | | | RETARDANT TREATED WOOD, WOOD OF TYPE | | | III | | | SIZES OR OF 1-HOUR RESISTANT | | | CONSTRUCTION.ANNOTATE THE PLANS TO | | | DEMONSTRATE COMPLIANCE. | | | | | | 9) FBC* F102.2.4ROOF COVERINGS, ON | | | BUILDINGS LOCATED IN THE FIRE DISTRICT, | | | SHALL CONFORM TO THE REQUIREMENTS OF | | | CLASS A OR B ROOF COVERINGS, AS DEFINED | | | IN FBC 1505.ANNOTATE THE PLANS TO | | | DEMONSTRATE COMPLIANCE. | | | | | | 10) THE PLANS DO NOT PROVIDE | | | INFORMATION FOR WORK TO BE COMPLETED IN | | | THE PUBLIC PROPERTY. SEE CHAPTER 33, | | | WHERE COVERED WALKWAYS WILL BE REQUIRED | | | 3304, CONSTRUCTION OF WALKWAYS, FENCES | | | AND PROTECTIVE COVERINGS. | | | | | | 11) PROVIDE INFORMATION ON THE SHEET | | | PILING, EXCAVATION ,DENSAFICATION OF | | | SOILS AND IF SOIL NAILS ARE GOING TO | | | BEREQUIRED AND DEWATERING. DEPENDING ON | | | THE SEQUENCE OF EVENTS THERE IS | | | POSSIBILITIES OF THE SHEET PILE GIVING | | | WAY BECAUSE OF SOILS VIBRAFLOTATION. | | | | | | 12) PROPERTY LINES- ON THE NORTH SIDE | | | OF THE BUILDING SHEET A.5/A.6 INDICATE | | | FRONT ENTRY DOORS SWINGING PAST THE | | | PROPERTY LINE. 3203.1 DOORS SHALL NOT | | | OPEN OR PROJECT UPON PUBLIC PROPERTY. | | | | | | 13) SOUTH SIDE OF THE BUILDING SHEET | | | A.5/A.6 CURB IS PAST THE PROPERTY LINE. | | | | | | 14) BOTH SETS OF PLANS ARE MISSING THE | | | A-19 SHEET WHICH DEPICTS THE SOUTH | | | ELEVATION OF THE BUILDING. CONCERNS | | | THAT TABLE 600 ISSUES EXIST SINCE THE | | | BUILDING IS ON THE PROPERTY LINE AND | | | THE ALLEY IS ONLY 14' WIDE. SINCE THE | | | STRUCTURE IS DIRECTLY ON THE PROPERTY | | | LINE TABLE 600 ISSUES OCCUR. | | | 14A) THE WALL SECTION THAT IS 6'-0" | | | AWAY | | | FROM THE PROPERTY LINECAN HAVE 20% | | | OPENINGS & REQUIRES A 3 HR WALL.!/2 OF | | | ALLEY OR 7'+6'= 13' OR 20% ALLOWABLE | | | OPENINGS, PER FLOOR!SEE 705.1.1.2 FOR | | | OPENINGS LESS THAN 15' FROM THE | | | PROPERTY LINE. | | | 14B) THE WALL SECTIONS THAT ARE RIGHT | | | ON THE PROPERTY LINE(0'-3') HAVE NO | | | ALLOWABLE OPENINGS AND REQUIRE A 4 HR | | | WALL. | | | 14C) PROVIDE THE EQUIVALENT THICKNESS | | | REQUIRED FOR BEARING AND NONBEARING | | | CONCRETE BLOCK. SEE 709.3.1. DO NOT | | | PROVIDE A UL RATING BUT THE ACTUAL | | | EQUIVALENT THICKNESS FROM THE BLOCK | | | MANUFACTURE FOR2HR, 3 HR & 4HR WALLS. | | | | | | 15) SHEET A-27 MEZANINES, THE AREA OF | | | THE MEZZANINES IS OVER THE 1/3 OF THE | | | ROOM IN WHICH IT IS LOCATED. SEE | | | 503.2.3.2. ENCLOSED SPACE UNDER A | | | MEZZANINE SHALL NOT BE INCLUDED IN A | | | DETERMINATION OF THE SIZE OF THE ROOM | | | OR SPACE IN WHICH THE MEZANINE IS | | | LOCATED. RECALCULATE AREAS. | | | | | | 16)A.5 WALL LEGEND INDICATES VARIOUS | | | BLOCK OR SOLID CONCRETE WALL AND THEIR | | | RESPECTIVE HR. RATING. PROVIDE THE | | | EQUIVALENT THICKNESS AS DESCRIBED IN | | | TABLE 709.3.1. NOTE ALSO NO 3HR WALLS | | | PROVIDED 0'-3' REQUIRES A 3HR RATED | | | WALL. THE BLOCK INFORMATION SHOULD COME | | | FROM THE BLOCK MANUFACTURER NOT A | | | UL LISTING. | | | | | | 17) A.5/A.6 SEE STAIRWAYS, 1007.1.5 | | | ENCLOSED EXIT STAIRWAYS THAT CONTINUE | | | BEYOND THE FLOOR OF DISCHARGE SHALL BE | | | INTERRUPTED AT THE FLOOR OF DISCHARGE | | | BY PARTITIONS, DOORS OR OTHER EFFECTIVE | | | MEANS. | | | | | | 18) SEE DOOR SCHEDULE A.35 IS MISSING | | | PROTECTION OF OPENINGS IN INTERIOR | | | WALLS,( 705.1.2) SEE TABLE 705.1.2 FOR | | | THE REQUIRED RATINGS. | | | | | | 19) TRASH ROOM SEE A.6/A.35 MISSING THE | | | | | | DOOR RATING FOR THE TRASH TERMINATION | | | ROOM. SEE 705.2.4.4. | | | | | | 20) THE VARIOUS FLOORS (2-8) INCLUDE | | | THE | | | | | | PHRASE TRASH ROOM (EXAMPLEROOM 103 ON | | | A.10). THISDETAIL DOESN'T PROVIDE AN | | | ACCURATE DETAIL WITH THE WORD ROOM, AT | | | BEST IT IS A VESTIBULE, THE CODE DOES | | | REQUIRE A ACCESS ROOM. THE SWING DOOR | | | THAT IS NOT NUMBERED OR LABELED WILL | | | MEET THE INTENT OF THE CODE IF THE | | | 3/4 HR RATING IS MET SEE 705.2.4.2. | | | | | | 21)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | THERE IS A SPACE BETWEEN THE TRASH | | | ROOM, | | | STAIRWELL# 3, THAT IS NOT LABELED, WHAT | | | WILL THIS AREA BE USED FOR? IF IT IS A | | | CHASE PROVIDE A 2 HR RATED ASSEMBLY.SEE | | | A.10, A.12, A.14 & A.16. | | | | | | 22) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | THERE IS ALSO 2 AREAS ON EACH SIDE OF | | | STAIRWELL# 2 THAT IS NOT CLEAR WHAT | | | THIS | | | AREA MAY BE USED FOR, IT IS DIRECTLY | | | FOUND ON A.9, A.11 & A.13. | | | | | | 23) INDICATE COMPLIANCE WITH 3003.4.1 | | | LEVATOR STRETCHER REQUIREMENTS. | | | | | | 24) 1606.1.4(1) IN WIND BORNE DEBRIS | | | REGIONS, EXTERIOR GLAZING THAT RECEIVES | | | POSITIVE PRESSURE IN BUILDINGS SHALL BE | | | ASSUMED TO BE OPENINGS UNLESS SUCH | | | GLAZING IS IMPACT RESISTANT OR | | | PROTECTED | | | WITH AN IMPACT RESISTANT COVERING MEET- | | | ING THE REQUIREMENTS OF SSTD 12, ASTM | | | E 1886 AND ASTM E 1996 OR MIAMI-DADE. | | | 1) GLAZED OPENINGS LOCATED WITHIN 30 | | | FT | | | OF GRADE SHALL MEET THE REQUIREMENTS OF | | | LARGE MISSLE TEST.SEE COPY OF CITY OF | | | W.P.B. INTERPRETATION OF HURRICANE | | | STANDARDS FOR LARGE PROJECTS. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS- FIXED OR OPERATABLE | | | B) PANELWALL-STOREFRONT | | | C) GLAZED EXTERIOR DOORS | | | D) SOLID EXTERIOR DOORS | | | E) MULLIONS | | | F) VENTS | | | G) STRUCTURAL COMPONENTS- TRUSS | | | ANCHORS | | | CONCRETE ADMIXTURES, RAILINGS | | | H) ROOFING PRODUCTS- AND INSULATION. | | | THE ABOVE IS MENTIONED AS TO | | | REQUIREMENTS TO OBTAIN A BUILDING | | | PERMIT. THE NOTES FOUND ON A.35 NOTE | | | FOR | | | WINDOWS AND STOREFRONT ARE TO BE UNDER | | | A | | | SEPERATE PERMIT. AT WHAT TIME WILL | | | THESE ITEMS BE ADDRESSED? SHOULD THE | | | BUILDING BE CLASSIFIED AS OPEN OR | | | PARTIALLY OPEN SINCE NO TIME FACTOR IS | | | MENTIONED TO WHEN THEY WILL BE | | | INSTALLED? | | | | | | 25) THE OTHER ISSUE THAT NEEDS TO BE | | | CLARIFIED, THERE CAN ONLY BE ONE | | | CLASSIFICATION FOR A BUILDING OR | | | STRUCTURE EITHER OPEN, PARTIALLY | | | ENCLOSED OR ENCLOSED. . SEE ASCE 7-98 | | | 6.5.9.4. SHEET S-4.1 WIND DESIGN | | | INDICATES THAT YOU ARE DESIGNING TO A | | | HIGH VELOCITY ZONE "C", AND EXPOSURE | | | OF 146 MPH. S5.2 INDICATESE PARTIALLY | | | ENCLOSED BUT COEFICIENTS FOUND ON S4.1 | | | INDICATEA CLOSED BUILDING 0.18+-, | | | PLEASE INDICATE FINAL ANALYSIS? | | | | | | 26) A-37 DETAILS 6 & 7, SOFFITS, DROP | | | CEILINGS, OR TRAY CEILINGS ALL INDICATE | | | THE SAME PHRASE," TO BE PROPERLY | | | ANCHORED TOTHEUNDERSIDE OF STRUCTURE" | | | BUT THE DESIGN TEAM LACKS INDICATING HOW | | | TO ACHIEVE THIS TASK? | | | 104.2.1 W.P.B. ADMINISTRATIVE CODE | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN | | | INFORMATION, IN THE FORM OF NOTES OR | | | OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | | CONFORMITY WITH THE TECHNICAL CODES. | | | SUCH INFORMATION SHALL BE SPECIFIC AND | | | THE TECHNICAL CODES "SHALL NOT BE CITED | | | AS A WHOLE OR IN PART, NOR THE TERM | | | "LEGAL" OR ITS RQUIVALENT BE USED AS A | | | SUBSTITUTE FOR SPECIFIC INFORMATION". | | | | | | 27) TYPE II CONSTRUCTION 604 REQUIRES | | | STRUCTURAL MEMBERS TO BE NON | | | COMBUSTIBLE. | | | A.15 WOOD TRELLIS EIGHTHFLOOR TO BE | | | NONCOMBUSTIBLE, F102.2.7 FIRE DISTRICT | | | A.20 THE POOL HOUSE, STAIR AND | | | ELEVATION | | | SHEETS INDICATE WOOD RAFTERS. | | | A.24 WALL SECTIONS A&D INDICATE THE USE | | | OF 5/8" CDX PLYWOOD FOR ROOF SHEATHING. | | | ALSO 2X6 WOOD FACIA OVER 1X8????? | | | | | | 28) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | FOR THE POOL HOUSE AND ASSOCIATED | | | STRUCTURES ATOP THE BUILDING, NO | | | INFORMATION WAS SUBMITTED TO BE ABLE TO | | | DO A THROUGH PLAN REVIEW!!!!!!!! | | | S-1.6A/S-1.6B POOL DECK PLANS DO NOT | | | INDICATE STRUCTURAL DETAILS FOR THE POOL | | | STRUCTURE, SPA NOR THE COLUMN FRAMING | | | FOR THE BREEZEWAYS. | | | | | | 29) A.15 THERE HAS BEEN NO INFORMATION | | | SUBMITTED FOR AN ELEVATOR LOBBY FOR | | | NONE | | | OF THE ELEVATORS ON THE ROOF TERRACE | | | LEVEL.SEE 412.6. | | | | | | 30) THE FIRE SPRINKLER PLANS DO NOT | | | INDICATE THE USE OF FIRE SPRINKLERS FOR | | | THE STRUCTURES ON THE ROOF TERRACE | | | LEVEL. SEE ATTACHMENT NFPA 13 8.14.7 | | | EXTERIOR ROOFS OR CANOPIES, INDICATE | | | HOW | | | TO ACHIEVE CODE COMPLIANCE. | | | | | | 31) ASSUMPTION: FIRE SPRINKLERS FOR THE | | | | | | POOL ROOF TERRACE LEVEL NOR THE POOL | | | DECK LEVEL, ISIT ASSUMED THAT AREA OF | | | RESCUE WILL BE PROVIDED UNDER SECTION | | | 11-4.3.11? | | | | | | 32) A-24 INDICATES THE USE OF CAST | | | STONE | | | WITH A THICKNESS OF 1"-6". SHOW | | | COMPLIANCE WITH 1403.2.7. | | | | | | 33) STAIRWELLS INDICATE HOW PLANS ARE TO | | | COMPLY WITH 11-4..4.2 HEADROOM. | | | | | | 34) A-23 DROP OFF ZONE 11-4.6.5 | | | PASSENGER LOADING ZONE PROVIDE THE | | | VEHICLE ACCESS ROUTE WITHREQUIRED HEAD | | | ROOM FROM THE ENTRY TO LOADING ZONE BACK | | | TO THE EXIT. | | | | | | 35) A-5 ACCESSIBLE PATH, ACCESS AISLE IS | | | THERE A CURB @ COLUMN LINE 7/F1AND | | | DROP OFF POINT? | | | | | | 36) POOL STRUCTURE: POOL TO BE UNDER A | | | SEPERATE PERMIT, THE STURTURAL WALLS | | | WILL BE BUILT WITH THE BUILDING, THIS | | | AGAIN IS AN ASSUMPTION. TO COMPLY WITH | | | 424. PUBLIC POOLS : | | | A) DOES THE POOL OFFER SUNKEN SEATING | | | OR IS THIS STAIRS? SEE 424.1.2.5.3 FOR | | | STAIRS, 424.1.2.5.4. | | | | | | 37) A-34 THE DOORS LEADING INTO THE POOL | | | AREA DOOR 12 & 16 SHALL COMPLY WITH SELF | | | CLOSING AND SELF LATCHING REQUIREMENTS, | | | SEE 424.1 DOH 64E-9.002(6) EFFECTIVE | | | BARRIER. | | | | | | 38) A-36 DETAIL # 23 EXTERIOR | | | GUARDRAIL; | | | 1015.2 HEIGHT. GUARDRAILS SHALL FORM | | | A VERTICAL PROTECTIVE BARRIER NOT LESS | | | THAN 42" HIGH. | | | 1015.3 OPENINGS. OPEN GUARDRAILS | | | SHALL HAVE INTERMEDIATE RAILS OR ORNA- | | | MENTAL PATTERNS SUCH AS A 4" DIAMETER | | | SPHERE CAN NOT PASS THROUGH. A BOTTOM | | | RAIL OR CURB SHALL BE PROVIDED THAT WILL | | | REJECT THE PASSAGE OF 2" DIAMETER | | | SPHERE. | | | | | | 39) A-36 EXTERIOR GUARDRAILS TO COMPLY: | | | 1608.2.3 THE GUARDRAIL SYSTEM SHALL BE | | | DESIGNED AND CONSTRUCTED TO RESIST A 200 | | | LB CONCENTRATED HORIZONTAL LOAD APPLIED | | | ON A 1 SQ FT AREA AT ANY POINT IN THE | | | SYSTEM INCLUDING INTERMEDIATE RAILS OR | | | OTHER ELEMENTS SERVING THIS PURPOSE. | | | | | | 40) A-5 RAMP DOWN TO 9'-4" NOTE | | | INDICATESA 12" WIDE CONCRETE CURB SEE | | | | | | DETAILS 6/A-46? NO SUCH PLAN?STOPS AT | | | 40 | | | | | | 41) 411.4.2 6 AIR CHANGES PER HR/ | | | LEVEL. | | | M-3 INDICATES A 15,000 CFM FAN | | | EXHAUSTING , CENTERED IN A 50"-0" | | | OPENING. PLANS DO NOT INDICATE ANY MAKE | | | UP AIR, THIS EXHAUST WILL BE PULLED | | | RIGHT BACK INTO THE GARAGE, EXPLAIN | | | RATIONAL? | | | | | | 42) SHOW COMPLIANCE WITH 412.5 SMOKE | | | CONTROL, M-16 SMOKE ZONE CONTROLS/ ZONE | | | II, PLANS INDICATE THE USE OF | | | PRESSURIZATION, THIS STILL DOESN'T | | | REMOVE SMOKE, SEE 412.5. | | | | | | 43) M-6 EMERGENCY GENERATOR INDICATES A | | | 6" EXHAUST PIPE W/ 1 1/2" CALCIUM | | | SILICATE WRAP THROUGH THE 2HR RATED | | | FLOOR SLAB. 705.6.1 PROVIDE THE | | | ASSEMBLY | | | APPROVED FOR THIS APPLICATION. | | | PENETRATIONS OF HORIZONTAL ASSEMBLIES. | | | | | | 44) A-7 AUTO RAMP TO THE MEZZANINE FLOOR | | | PLAN INDICATES OPENSIDED RAMP, PROVIDE | | | INFORMATION FOR COMPLIANCE WITH | | | 1608.2.3. PARKING GAURDRAILS, IMPACT | | | GAURDRAILS, AND BOLLARDS. BOLLARDS | | | INDICATE A SECTION )/A-000.????? | | | | | | 45) A-8 PROVIDE FLOOR SLOPES AT THE | | | HANDICAPED PARKING AT THE EAST END OF | | | THE BLDG. DRAINAGE GRATE IN THE MIDDLE | | | OF THE HANDICAPPED SPACE? | | | | | | 46) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | A-9/A-10 NO INFORMATION IS PROVIDED FOR | | | WALLS AND GATES OF PRIVATE LANAI? | | | | | | 47)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | PLANS ARE NOT COMPLETE AND THE ANSWERS | | | TO THE QUESTIONS MAY RESULT IN | | | ADDITIONAL COMMENTS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-14 |
Time |
15:28 |
Rev Time |
15.00 |
| Received By |
dpalmer |
Date |
2005-07-12 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2005-07-14 00:00:00 | ********* UNSAT 3RD REVIEW ************ | | | | | | "THE PLACE VIA CLEMATIS" | | | | | | PLEASE SEE COMMENTS FROM PREVIOUS TWO | | | REVIEWS WHICH STILL NEED TO BE | | | ADDRESSED. | | | | | | PLEASE ALSO SEE NEW COMMENTS DUE TO | | | CHANGES IN PLANS/DESIGN AND SOME SHEETS | | | MISSING FROM PREVIOUS SUBMITTED PLANS. | | | | | | THESE ARE TAKEN DIRECTLY FROM PREVIOUS | | | TWO REVIEWS IN NUMMERICAL ORDER. | | | | | | 1)NOTE: NOTE #1 NO, PLEASE SEE LETTER | | | COULD NOT BE LOCATED IN PACKAGE. | | | | | | 2)NOTE: NOTE #2 NO, PLEASE SEE OUTWARD | | | SWINGS ON DOORS. PLEASE CORRELATE ALL | | | SHEETS SHOWING ELECTRICAL ROOMS ETC. | | | PLEASE HAVE PLANS INDICATE GUARD RAILS | | | FOR EGRESS PROTECTION FROM SECOND FLR | | | GEN RM. PLEASE UNDERSTAND ANY EGRESS IN | | | CASE OF AN EMERGENCY OR OTHER MAY RESULT | | | IN A LIFE SAFETY SITUATION AS SHOWN ON | | | PLANS. | | | PLEASE SEE DOORS WERE MOVED IN MAIN | | | ELECTRICAL ROOM, HOWEVER, PLEASE SEE | | | WALLS AND DOORS ARE SHOWN BUILT DIRECTLY | | | | | | IN FRONT OF ELECTRICAL EQUIPMENT. | | | 110.26 | | | PLEASE SEE MINIMUM STANDING/WALKING AREA | | | ON THE OUTSIDE OF ELECTRICAL ROOM AFTER | | | LEAVING DOOR SWING AREA. PLEASE SEE | | | PLANS STILL MENTIONS: A SIGN TO BE | | | PLACED AT DOORS LEAVING ELECTRICAL TO | | | READ; "OPEN DOOR CAREFULLY, WATCH FOR | | | CARS ON OTHERSIDE OF DOORS" PLEASE KNOW | | | IN AN EMERGENCY SITUATION WHEN THE | | | POSSIBILTY OF SOMEONE BEING BLINDED OR | | | ON FIRE;A SIGN WILL NOT HELP IN EXITING | | | ROOM AND ONCE AGAIN CREATING AN ADDITION | | | LIFE SAFTEY HAZARD FOR THE PERSON(S) | | | EXITING ROOM. | | | | | | NOTE FOR PANIC HARDWARE WAS PLACED ON | | | A-SHEETS, HOWEVER PLEASE PLACE NOTE ON | | | ELECTRICAL PLANS FOR ELECTRICAL RMS. | | | | | | 3)NOTE: NOTE #3 OK. | | | | | | 4)NOTE: NOTE #4 OK. | | | | | | 5)NOTE: NOTE #5 OK, CIRCUITS ADDED, | | | HOWEVER PLEASE SEE CIRCUITING PER ROOM | | | PER 620.23,.24. ONLY ONE ELEVATOR | | | MACHINE RM PER CIRCUIT. | | | PLEASE SEE NEW NOTES FOR ELEV RM #4. | | | | | | 6)NOTE: NOTE #6 NO, PLEASE SEE MANY | | | RECEPTS FOR WALL SPACE ARE STILL | | | MISSING. PLEASE SEE MOST LOCATIONS ARE | | | REDLINED. 210.52 | | | | | | 7)NOTE: NOTE #7 OK. | | | | | | 8)NOTE: NOTE #8 OK, HOWEVER PLEASE SEE | | | NEW NOTE FOR NOTE ON E-19. | | | | | | 9)NOTE: NOTE #9 OK. | | | | | | 10)NOTE: NOTE #10 OK. | | | | | | 11)NOTE: NOTE #11 OK, SEE NEW NOTES. | | | | | | 12)NOTE: NO, SEE NOTE #3 FROM PREVIOUS | | | REVIEW. PLEASE SEE SOME AREAS ARE SHOWN | | | WITH LIVING RM. PLEASE ALSO SEE COMMENTS | | | ABOUT CIRCUITING FOR DINING RM AREAS. | | | | | | 13)NOTE: NOTE #13, OK, SHEETS SUBMITTED, | | | HOWEVER SEE NEW NOTES DUE TO REVIEW | | | BEING POSSIBLE AT THIS TIME. | | | | | | 14)NOTE: NOTE #14 NO, PLEASE SEE MISSING | | | KITCHEN GFI RECEPTS PER 210.52C1, | | | 210.8A6. PLEASE SEE SOME AREAS REDLINED | | | ON PLANS. | | | | | | 15)NOTE: NOTE #15 NO, PLEASE SEE | | | PREVIOUS NOTES: PLEASE SEE SEE MANY | | | RECEPTSWHICH ARE ON SM APPL CIRCUITS | | | WHICH ARE IN AREAS NOT PERMITTED UNDER | | | NEC 210.52B1 | | | | | | 16)NOTE: NOTE #16 OK. | | | | | | 17)NOTE: NOTE #17 OK. | | | | | | 18)NOTE: NOTE #18 OK, | | | | | | 19)NOTE: NOTE #19 NO, SEE PREVIOUS NOTES | | | #4 OF SECOND SECTION. | | | MANY METER CENTERS STILL SHOWN AS | | | "MAINS". | | | | | | 20)NOTE: NOTE #20 OK. | | | | | | 21)NOTE: NOTE #21 OK. SEE NEW NOTES. | | | | | | 22)NOTE: NOTE #22 OK. | | | | | | 23)NOTE: NOTE #23 OK. | | | | | | 24)NOTE: NOTE #OK. | | | | | | 25)NOTE: NOTE #25 OK. | | | | | | 26)NOTE: NOTE #26 OK. | | | | | | 27)NOTE: NOTE #27 OK. | | | | | | 28)NOTE: NOTE #28 OK, HOWEVER SEE NEW | | | NOTES. | | | | | | 29)NOTE: NOTE #29 NO, SPECS SUBMITTED | | | LIKE PREVIOUS REVIEW, HOWEVER SPECS | | | SUBMITTED STILL DO NOT CORRELATE WITH | | | PLANS FOR SIZING. | | | PLEASE SEE NO SPECS SUBMITTED FOR SUB | | | BASE FUEL TANK FOR FIRE REVIEW. | | | | | | 30)NOTE: NOTE #30, NO, PLEASE SEE RISER | | | NOTES FOR GENERATOR. | | | PLEASE ALSO SEE NOTES PERATAINING TO | | | RISER ETC. | | | | | | 31)NOTE: NOTE #31 NO. | | | PLEASE SEE BRKRS FROM GEN TO ATS AND OCP | | | LISTED ON NOTES. | | | PLEASE SEE NEW NOTES ALSO. | | | | | | 32)NOTE: NOTE #32 NO, PLEASE SEE THERE | | | ARE NUMEROUS ITEMS ON ELECTRICAL RISER | | | DIAGRAM AND NOTES FOR FEEDERS ETC WHICH | | | DO NOT CORRELATE. | | | PLEASE SEE NEW NOTES PERTAINING TO | | | "FEEDER SCHEDULE NOTES" AND "ELECTRICAL | | | RISER DIAGRAM". | | | | | | 33)NOTE: NOTE #33 OK. | | | | | | 34)NOTE: NOTE #34, NO, SEE NEW NOTES FOR | | | EQUIPMENT GROUNDING MISSING ETC. | | | | | | 35)NOTE: NOTE #35 NO, SEE PREVIOUS TWO | | | REVIEWS. | | | 250.6,250.24,250.110,.250.122 SEE NEW | | | NOTES. | | | | | | 36)NOTE: NOTE #36 OK, HOWEVER PLEASE SEE | | | 250.104 TO BE LISTED ON GROUNDING | | | ELECTRODE DETAIL. | | | PLEASE SEE SHEETS E-19 MAKES REFERENCES | | | TO CODES THAT GROUNDING SHALL BE | | | INSATLLED BY, HOWEVER PLEASE SEE FBC | | | 104.2.1, TECHNICAL CODES SHALL NOT BE | | | USED IN LEIU OF PROVIDING THE DETAIL ON | | | PLANS. | | | | | | 37)NOTE: NOTE #37 NO, PLEASE SEE THERE | | | ARE STILL LOCATIONS ON PLANS WHICH STILL | | | REFERENCE CODES FROM 1996/1999 CODES. | | | | | | 38)NOTE: NOTE #38 OK. | | | | | | 39)NOTE: NOTE #39 OK, NO 277V SYSTEMS | | | PRESENT. | | | | | | 40)OK | | | | | | 41)OK. | | | | | | 42)OK. | | | | | | 43)OK. | | | | | | **************************************** | | | PLEASE SEE NOTES DIRECTLY TAKEN FROM | | | "NEW NOTE" ON 2ND REVIEW". | | | | | | 1)NOTE: NOTE #1 OK. | | | | | | 2)NOTE: NOTE #2 OK. | | | | | | 3)NOTE: NOTE #3 NO, PLEASE SEE MANY | | | AREAS SHOWN AS DINING AND LIVING RM | | | TOGETHER WHEN "DINING RM/AREA" | | | DESIGNATION SHOULD BE MOVED TO CORRELATE | | | WITH CIRCUTING SHOWN ON PLANS. | | | PLEASE SEE AREAS WHERE A "HALLWAY/FOYER" | | | AREA RECEPT IS ON SMALL APPLIANCE | | | CIRCUIT. | | | PLEASE SEE MANY AREAS REDLINED ON PLANS. | | | | | | 4)NOTE: NOTE #4 NO, PLEASE SEE PREVIOUS | | | NOTES , MANY AREAS ON PLANS WHERE METER | | | CENTERS ARE STILL SHOWN AS BEING | | | "MAINS", PLEASE CORRECT. SEE NEW NOTES | | | ALSO. | | | | | | 5)NOTE: NOTE #5, OK, LOAD CALCULATIONS | | | AND PANEL SCHEDULES NOW SHOW AHU/HEAT | | | LOADS @125%. PLEASE KNOW: ONLY THE OCP | | | IS REQUIRED TO BE 125%. HOWEVER, IT IS | | | PERMISSIBLE TO TO HAVE LOADS FIGURED AT | | | A HIGHER AMOUNT THAN IS REQUIRED. | | | NO CORRECTION IS NEEDED. | | | | | | 6)NOTE: NOTE #6 OK. | | | | | | 7)NOTE: NOTE #7 OK. | | | | | | 8)NOTE: NOTE #8 NO, PLEASE SEE MANY | | | RECEPTS STILL MISSING . PLEASE SEE | | | PREVIOUS NOTES FROM BOTH REVIEWS. | | | | | | 9)NOTE: NOTE #9 OK, SEE ALL SHEETS WERE | | | SUBMITTED, HOWEVER PLEASE SEE SOME NOTES | | | PERTAINING TO THESE SHEETS WHICH COULD | | | NOT REVIEWED ON PREVIOUS SUBMITTAL. | | | | | | 10)NOTE: NOTE #10 OK, HOWEVER PLANS SEE | | | ELECTRICAL RM #1 EAST ELEVATION, ONE | | | SHOWS 110,000 AND THE OTHER 100,000? | | | | | | 11)NOTE: NOTE: OK, ALL ELECTRICAL | | | REMOVED FROM VAULT. | | | | | | 12)NOTE: NOTE #12 NO, SAME COMMENT. | | | | | | 13)NOTE: NOTE #13 OK. | | | | | | 14)NOTE: NOTE #14 OK. | | | | | | 15)NOTE: NOTE #15 OK, HOWEVER SEE NEW | | | NOTES; | | | | | | 16)NOTE: NOTE #16 NO, PREVIOUSLY NOTED | | | ON THIS REVIEW. | | | | | | 17)NOTE: NOTE #17 OK, HOWEVER SEE NEW | | | NOTES FOR FEED FROM FPL. | | | | | | 18)NOTE: NOTE #18 NO, PLEASE SEE ALL | | | UNPROTECTED CONDUCTORS/BUS-DUCT IS STILL | | | SHOWN "INSIDE" BLDG. INSTALLATION AS | | | SHOWN SHALL NOT BE PERMITTED AS SHOWN. | | | THIS WAS GONE OVER IN MEETING ,YET PLANS | | | STILL CAME BACK WITH NO CORRECTIONS? | | | PLEASE SEE 230.70,230.6 ETC. | | | | | | 19)NOTE: NOTE #19 NO, PLEASE SEE HDP-2 | | | STILL SHOWN AS A "SHUNT TRIP".?? | | | | | | 20)NOTE: NOTE #20 NO,? PLEASE SEE HDP-2 | | | IS STILL SHOWN AS GF PROTECTED. PLEASE | | | ALSO SEE NEW NOTE ABOUT ATS. | | | PLEASE SEE 230.95,240.13 GF PROTECTION | | | IS NOT REQUIRED, HOWEVER MAY BE | | | INSTALLED. PLEASE ATS NOTE: | | | | | | 21)NOTE: NOTE #21 OK? NOT NEEDED , | | | HOWEVER MAY BE DONE. | | | | | | | | | **************************************** | | | NEW NOTES FOR 3RD REVIEW. | | | | | | 1)NOTE: PLEASE SEE ELEVATOR RM #4. | | | PLEASE SEE STATE ELEVATOR CODE. ELEVATOR | | | MACHINE ROOM SHALL CONTAIN NO OTHER | | | EQUIPMENT, USEAGE , ELECTRICAL EQUIPMENT | | | ETC UNLESS DIRECTLY USED FOR ELEVATOR | | | EQUIPMENT. | | | PLEASE SEE ROOM #4, SHOWS "TRASH RM, AND | | | "MECH RM" THIS IS NOT PERMITTED. | | | THESE RMS WILL BE REQUIRED TO BE | | | SEPARATED. | | | PLEASE ALSO SEE REQUIREMENTS FOR TRASH | | | RMS UNDER LS 101. | | | | | | 2)NOTE: PLEASE CORRELATESIZES OF | | | SWITCH GEAR MAINS. PLEASE SEE ONE SHEET | | | SHOWS 3000A'S, RISER SHOWS 4,000A'S? | | | PLEASE SEE REDLINED PLANS. SG #5? | | | | | | 3)NOTE: PLEASE SEE LS 7-9. PLEASE SEE | | | ALTERNATING CIRCUITS FOR EM LTS IN | | | STAIRS WILL BE REQUIRED. THIS IS TO | | | ALLEAVIATE EGRESS AREAS TO BE IN TOTAL | | | DARKNESS BYT THE TRIPPING OF A SINLGE | | | BRKR. PLEASE SEE A BATTERY BACK UP | | | FIXTURE MAY BE INSTALLED AT EVERY OTHER | | | LEVEL AS AN OPTION. PLEASE SEE EGRESS | | | HALLWAYS AS SHOWN ON PLANS ALREADY HAVE | | | BATTERY BACK LTS SHOWN. EVEN IF A BRKR | | | FROM EDP TRIPS, EGRESS LIGHTNING WILL | | | STILL BE PROVIDED. | | | | | | 4)NOTE: PLEASE SEE SHEET #19 IS NOW | | | SUBMITTED. PLEASE SEE SD NOTES: | | | ONE NOTE MENTIONS FOR SD'S TO BE WIRED | | | TO KITCHEN/BATH LIGHTING CIRCUIT, | | | HOWEVER CIRCUITING ON PLANS DO NOT | | | CORRELATE WITH THIS STATEMENT. | | | PLEASE SEE KITCHEN/BATH LIGHTING | | | CIRCUITS DO NOT INDICATE REQUIRED ARC | | | FAULT PROTECTION AS REQUIRED UNDER 2002 | | | NEC 210.12. PLEASE ADJUST NOTE OR | | | PLANS/CIRCUITS ETC. | | | | | | PLEASE SEE SECOND SD NOTE MENTIONS SD'S | | | MAY BE WITHIN 20' OF KITCHEN COOKING | | | APPLIANCE. THIS IS PERMITTED HOWEVER | | | PLEASE SEE NFPA-72 8-1.4.2, A SPECFIC | | | TYPE OF SD'S SHALL BE REQUIRED FOR ANY | | | SMOKE DETECTORS CLOSER THAN 20' TO A | | | COOKING APPLIANCE. | | | | | | 5)NOTE: PLEASE CORRELATE RISER , RISER | | | NOTESETC, PLEASE SEE RISER, PANEL | | | SCHEDULES ETC INDICATE BUS-DUCT AND ALOS | | | INDICATES FEEDERS ETC. | | | PLEASE SEE NUMEROUS ITMES WHICH DO NOT | | | CORRELATE. | | | | | | A) PLEASE SEE MAINS LISTED ON RISER | | | DIAGRAM EQUIPMENT SCHEDULE ITME #4? THIS | | | COULD NOT BE LOCATED ON RISER. | | | | | | B) PLEASE SEE MAIN DISC SHOWN AS 150A | | | FOR ELEVATORS , YET NOTE MENTIONS | | | 200A'S. | | | | | | C)PLEASE SEE FEEDER SCHEDULES AND | | | EQUIPMENT NOTES DO NOT CORRELATE FOR | | | MAINS SEC'S OR BUS-DUCT. | | | | | | D)PLEASE SEE FEEDER SCHEDULE 5,7,8,9 AND | | | 10. PLEASE SEE THESE DO NOT CORRELATE | | | WITH PANEL SCHEDULES FOR FEEDERS, ETC. | | | PLEASE SEE THESE DO NOT INCLUDE ANY | | | EQUIPMENT GRNDS? | | | | | | E)NOTE:PLEASE SEE SW GR #2 ONLY SHOWS | | | ONE FEEDER TO MC'S. ETC ETC. | | | MOST OF THESE ITEMS WERE REDLINED. | | | | | | 6)NOTE: PLEASE SEE SEE FEEDER SCHEDULE | | | MENTIONS ALL FEEDS TO APT UNITS TO BE IN | | | EMT? PLEASE VERIFY THIS.PLEASE SEE EMT | | | MAY NOT BE INSTALLED IN CONCRETE. | | | ONLY IF OVERHEAD. | | | | | | 7)NOTE:PLEASE SEE EQUIPMENT GROUNDING | | | CONDUCTOR SHOWN FROM FPL TO FIRST MEANS | | | OF DISCONNECT FOR FIRE PUMP. PLEASE SEE | | | 250.6, 250.24, EQP GRNDS SHALL ONLY BE | | | INSTALLED "AFTER" THE FIRST MENS OF | | | DISCONNECT. | | | | | | 8)NOTE: PLEASE SEE OTHER CONDUITS ETC ON | | | RISER MISSING ANY MENTION OF EQUIPMENT | | | GROUNDING CONDUCTORS. PLEASE SEE FEEDERS | | | FROM GEN TO FIRE PUMP AND EM ATS, EDP(SW | | | GR #4). | | | 250.110, 250.122 | | | | | | 9)NOTE: PLEASE SEE ATS FOR EM STAND-BY | | | IS NOTED AS GFCI PROTECTED? | | | PLEASE SEE EQUIPMENT PROTECTION WOULD BE | | | GF PROTECTED, NOT GFCI FOR PERSONNEL | | | PROTECTION. PLEASE SEE GF PROTECTION OS | | | NOT REQUIRED ON EM STAND-BY SYSTEMS OF | | | THIS VOLTAGE AND SIZE. 240.13,230.95 | | | ETC. THIS IS ONLY NOTED AS TO WHY ? | | | PLEASE SEE 701.17 FOR "LEGALLY REQUIRED | | | STAND-BY SYSTEMS". | | | | | | 10)NOTE: PLEASE SEE PREVIOUS NOTE FROM | | | THIRD REVIEW5)D: WHICH MENTIONS | | | CORRELATION OF FEEDER SCHEDULES. | | | PLEASE SEE FEEDERS FOR ALL RTU'S, POOL | | | PANEL. PLEASE SEE EDP'S AND HDP'S PANEL | | | SCHEDULES AND FEEDERS INDICATED AT THOSE | | | LOCATIONS. PLEASE CORRELATE. | | | SEE NEW NOTE IN REF TO POOL PANEL. | | | | | | 11)NOTE: PLEASE SEE NOTE #6 ON NOTES | | | LISTED ON THE UPPER RIGHT HAND CORNER OF | | | RISER DIAGRAM SHEET. THIS MENTIONS: | | | "ONLY FOUR ELEVATOR THRU EMERGENCY | | | GENERATOR"?? | | | PLEASE CLARIFY AS ONLY ONE ELEVATOR IS | | | LISTED ON SWITCH GEAR MAIN #4? | | | PLEASE SEE FIRE DEPARMENT REQUIREMENTS | | | FOR ELEVATOR ON EM GEN SHALL ALSO BE | | | STRETCHER ACCESSSIBLE. SEE ANY FIRE | | | REVIEW NOTES FOR THIS. | | | | | | 12)NOTE: PLEASE SEE SWITCH GEARR #4 | | | INDICATES CONNECTED LOAD OVER 1600 A'S | | | ON A 2000A MAIN WITH A 2000A FEED FROM | | | FPL. THIS IS OK, HOWEVER , PLEASE SEE | | | ATS IS ALSO SHOWN AS HAVING 2000A | | | CAPACITY, AND SERVICE ENTRANCE | | | CONDUCTORS FROM FPL SHOWN FOR 2000A'S | | | YET GENERATOR ONLY SHOWS A 1600A MCB? | | | PLEASE EITHER INCREASE FEED FROM | | | GENERATOR TO CORRLELATE WITHALL OTHER | | | EQUIPMENT TO 2000A'S OR PLEASE PROVIDE | | | LOAD CALCUALTIONS FOR ANY DERATING. | | | PLEASE BEAR IN MIND FUTURE POSSIBLE | | | LOADS OF ANY ADDITIONS. | | | PLEASE SEE 90.8WHICH REQUIRES PLANS | | | AND SPECIFICATIONS THAT PROVIDE AMPLE | | | SPACE IN RACEWAYS, SPARE RACEWAYS, AND | | | ADDITIONAL SPACES ALLOW FOR FUTURE | | | INCREASES IN THE USE OF ELECTRICITY. | | | DISTRIBUTION CENTERS LOCATED IN READILY | | | ACCESSIBLE LOCATIONS PROVIDE CONVENIENCE | | | AND SAFETY OF OPERATION. | | | THE REQUIREMENT FOR PROVIDING THE | | | EXCLUSIVELY DEDICATED EQUIPMENT SPACE | | | MANDATED BY 110.26(F) SUPPORTS THE | | | INTENT OF 90.8(A) REGARDING FUTURE | | | INCREASES IN THE USE OF ELECTRICITY. | | | DISTRIBUTION CENTERS SHOULD CONTAIN | | | ADDITIONAL SPACE AND CAPACITY FOR FUTURE | | | ADDITIONS AND SHOULD BE CONVENIENTLY | | | LOCATED FOR EASY ACCESSIBILITY. | | | THIS SHOULD ALSO BE TAKEN IN NOTE FOR | | | ALL SERVICE EQUIPMENT AND THE | | | POSSIBILITY OF ANY FUTURE EXPANTION. | | | PLEASE SEE NO LOAD CALCULATIONS WERE | | | SUBMITTED FOR MAINS 4 AND 5. IF LOAD | | | CALCULATIONS ARE SUBMITTED, PLEASE SHOW | | | ALL CONTINUOUS LOADS (3OR MORE HOURS) AT | | | 125%. 215.3,100,230.42 ETC. | | | | | | 13)NOTE: PLEASE SEE POOL PANEL IS NOW | | | SHOWN ON RISER AS NOTED IN NEW NOTE #10, | | | HOWEVER PLEASE SEE NO POOL PANEL | | | SCHEDULE WAS SUBMITTED? PLEASE ALSO | | | INCLUDE LOADS ON PANEL. PLEASE SEE | | | PREVIOUS NOTE ABOUT FEEDERS LISTED ON | | | RISER SCHEDULES, RISER AND HDP-3. | | | | | | 14)NOTE: PLEASE SEE MANY OF THE ABOVE | | | ITEMS AS NOTED HAVE BEEN REDLINED ON | | | PLANS AT AREAS OF NOTES. THIS IS IN NO | | | WAY EVERY LOCATION OF SAID COMMENTS. | | | | | | 15)NOTE: PLEASE BE SURE TO SEE ANY | | | POSSIBLE COMMENTS FROM OTHER REVIEWERS | | | WHICH MAY AFFECT ELECTRICAL PLANS. | | | IE: DOOR SWINGS, EGRESS ETC. | | | | | | 16)NOTE: PLEASE KNOW, A RESPONSE LETTER | | | LISTING REVIEWERS COMMENTS AND ACTION | | | TAKEN BY DESIGN TEAMWOULD HELP IN THE | | | REVIEW PROCESS. | | | | | | 17)NOTE: PLEASE REMOVE ANY OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. | | | IT IS SUGGEESTED AN ADDITIONAL MEETING | | | BE SET UP TO GO OVER ALL COMMENTS ONCE | | | ALL REVIEWS ARE DONE FOR TRADES. | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | | NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2005-07-12 00:00:00 | ONE ROLL AND SPECS BOOKS IN ELECTRICAL | | | FOR REVIEW. | | | WAITING FOR REVIEW, |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-04-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-15 |
Time |
15:43 |
Rev Time |
15.00 |
| Received By |
dpalmer |
Date |
2005-04-14 |
Time |
18:31 |
Sent To |
|
|
| Notes |
| 2005-04-15 00:00:00 | ********** UNSAT 2ND REVIEW *********** | | | | | | REVIEW FOR "THE PLACE VIA CLEMATIS"; | | | PLEASE SEE PLANS ARE SUBMITTED FOR "PLAN | | | REVIEW ONLY" AND NOT SUBMITTED FOR | | | PERMIT. | | | | | | PLEASE SEE MANY COMMENTS FROM PREVIOUS | | | REVIEW STTILL NEED TO BE ADDRESSED. | | | | | | PLEASE SEE NEW COMMENTS DUE TO MORE | | | INFORMATIONPROVIDED FROM PREVIOUS SET | | | OF PLANS. | | | HOWEVER PLEASE SEE NEW COMMENT FOR PAGES | | | MISSING. STILL UNABLE TO DO A FULL AND | | | COMPLETE REVIEW DUE TO PLANS AND SPECS | | | NOT BEING COMPLETE AT THIS TIME. | | | | | | 1)NOTE: NOTE #1, NO, PLEASE SEE LETTER | | | FOR ENGINEER TO BE SIGNED, DATED AND | | | NOTORIZED FOR LEGAL SIGNATURE. | | | TITLE BLOCKS "WHITED OUT" FOR FIRM NAME. | | | | | | 2)NOTE: NOTE #2 NO, PLEASE SEE OUTWARD | | | SWING IS NOW SHOWN, HOWEVER NOTE(S) | | | REQUESTED ON PLANS FOR PANIC HARDWARE | | | ETC WAS NOT ADDED. | | | | | | 3)NOTE: NOTE #3 OK | | | | | | 4)NOTE: NOTE #4 OK | | | | | | 5)NOTE: NOTE #5 NO, PLEASE SEE 620.22-25 | | | PLEASE ALSO SEE LAYOUT FOR ELEV MACHINE | | | ROOMS ARE MISSING ELECTRICAL EQUIPMENT. | | | ETC. | | | | | | 6)NOTE: NOTE #6 NO,PLEASE SEE PREVIOUS | | | NOTES: MANY WERE ADDED HOWEVER THERE ARE | | | STILL SOME MISSING, PLEASE SEE REDLLINED | | | PLANS.210.52 | | | | | | 7)NOTE:NOTE #7 OK. | | | | | | 8)NOTE: NOTE #8 OK. | | | | | | 9)NOTE: NOTE #9 OK. | | | | | | 10)NOTE: NOTE #10 OK. | | | | | | 11)NOTE: NOTE #11 OK. | | | | | | 12)NOTE: NOTE#12 NO, PLEASE SEE SOME | | | ROOM DESIGNATIONS WERE ADDED HOWEVER | | | SOME AREAS ARE STYILL MISSING. | | | PELASE ALSO SEE NEW COMMENTS PERTAINING | | | TO "DINING AREA". | | | | | | 13)NOTE: NOTE #13 NO, PLEASE SEE E-19 | | | WAS NOT SUBMITTED. PLEASE SEE NEW | | | COMMENTS PERTAINING TO "NEW " SHEETS | | | MISSING. | | | | | | 14)NOTE: NOTE #14 NO, PLEASE SEE SOME | | | STILL MISSING. REDLINED. | | | | | | 15)NOTE: NOTE #15 NO.PLEASE SEE MANY | | | AREAS RECEPTS ARE SHOWN IN AREAS OTHER | | | THAN "DINING AREA". PLEASE SEE SOME ARE | | | HALLWAYS, FOYERS, LIVING RMS? ETC. | | | PLEASE SEE PREVIOUS COMMENT ABBOUT | | | DEIGNATED AREAS. | | | | | | 16)NOTE: NOTE #16, OK. | | | | | | 17)NOTE: NOTE #17 OK. | | | | | | 18)NOTE: NOTE #18 OK. | | | | | | 19)NOTE: NOTE #19 OK, HOWEVER, PLEASE | | | SEE NEW NOTES BELOW PERTAINING TO | | | LABELING OF METER CENTERS. ETC. | | | | | | 20)NOTE: NOTE #20 OK. | | | | | | 21)NOTE: NOTE #21OK. | | | | | | 22)NOTE: NOTE #22 OK, HOWEVER PLEASE SEE | | | NEW NOTES PERTAINING TO LABELING AND | | | ELECTRICAL ROOMS. SAME AS #19. | | | | | | 23)NOTE: NOTE #23 NO. | | | | | | 24)NOTE: NOTE #24 OK, PLEASE SEE NEW | | | NOTES PERTAINING TO FIRE PUMP FEED FROM | | | EM DP. | | | | | | 25)NOTE: NOTE #25 OK. | | | | | | 26)NOTE: NOTE #26 OK. | | | | | | 27)NOTE: NOTE #27 NO. | | | | | | 28)NOTE:NOTE #28 NO, PLEASE SEE | | | INFORMATION FOR FIRE PUMP, FIRE PUMP | | | CONTROLLER/ATS DISCONNECTIN MEANS WAS | | | NOT SUPPLIED. | | | PLEASE ALSO SEE NEW NOTES DUE TO FIRE | | | PUMP FEED FROM EDP. | | | | | | 29)NOTE: NOTE #29 NO, SPECS FOR | | | GENERATOR WERE SUBMITTED , HOWEVER THEY | | | DO NOT CORRELATE TO PLANS. | | | | | | 30)NOTE: NOTE #30 NO, PLEASE SEE RISER. | | | | | | 31)NOTE: NOTE #31 NO. | | | | | | 32)NOTE: NOTE #32 NO. | | | | | | 33)NOTE: NOTE #33 OK | | | | | | 34)NOTE: NOTE #34 OK, HOWEVER SEE NEW | | | NOTES PERTAINING TO EQUIPMENT GROUNDING. | | | | | | 35)NOTE: NOTE #35, NO. | | | | | | 36)NOTE: NOTE #36 OK. | | | | | | 37)NOTE:NOTE #37 NO, PLEASE ALSO SEE | | | NEW NOTES PERTAINING TO MISSING SHEETS. | | | | | | 38)NOTE:NOTE #38 OK. | | | | | | 39)NOTE: NOTE #39 NO, SEE NEW NOTES | | | PERTAING TO MISSING SHEETS. | | | | | | 40)NOTE: NOTE #40 RESPONSE NOT NEEDED, | | | PLEASE SEE PLASN, ONCE AGAIN MOST AREAS | | | REDLINED FOR ABOVE NOTES AND FOR NEW | | | NOTES TO FOLLOW. | | | | | | 41)NOTE: NOTE #41 NO RESPOSE NEEDED. | | | | | | 42)NOTE: NOTE #42 NO, AS REQUESTED ON | | | PREVIOUS REVIEW, PLEASE "REMOVE" ALL | | | OLD/VOIDED SHEETS FROM SETSS AND ONLY | | | INSERT NEW REVISED SHEETS INTO THREE | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | PLEASE SEE THESE SHEETS WERE NOTE | | | REMOVED AND LEFT IN SETS. | | | | | | 43)NOTE: NOTE #43 , NO RESPONSE NEEDED. | | | | | | | | | ************** NEW NOTES ************* | | | | | | 1)NOTE: PLEASE SEE PANEL LOCATED ON | | | BATHRM, UNIT L/WD-3. | | | | | | 2)NOTE: PLEASE ALSO SEE SMALL APPLIANCE | | | CIRCUIT SHOWN IN BATH. L/WD-3 | | | 210.52C1 | | | | | | 3)NOTE: PLEASE SEE AREAS FOR DINING | | | NEED TO BE CLARIFIED. PLEASE SEE | | | PREVIOUS COMMENTS ABOUTAREAS WHICH | | | SHOWDEVICES ON SAME CIRCUITS AS SMALL | | | APPLIAANCE, HOWEVER SOME OF THESE AREAS | | | ARE NOT AREA ALLOWED TO BE ON SM APPL | | | CIRCUITS. | | | PLEASE SEE NEC 210.52B | | | | | | 4)NOTE: PLEASE SEE MANY LOCATION ON | | | PLANS, EQUIPMENT IS LABEL AS MAIN, 1OF 2 | | | ETC YET, THEY ARE NOT MAINS. | | | PLEASE SEE METER CENTERS WHICH ARE SHOWN | | | AS MAINS, PLEASE SEE ELECTRICAL | | | ROOM/AREA NEXT TO MAIN SWITCH GEAR WHICH | | | SHOW ADDITIONAL MAINS ALSO. | | | THE ATCUAL MAINS SHOULD BE THE ONLY | | | EQUIPMENT LABELED AS SUCH. PLEASE | | | RE-IDENTIFY ALL OTHER EQUIPMENT. | | | 215.5,230.2E ETC. | | | | | | 5)NOTE: PLEASE CORRELATE A/C, AHU LOADS | | | FOR UNITS. PLEASE SEE PANEL SCHEDULES | | | AND ACTUAL LOAD CALCULATIONS. | | | ONE SHOWS 7.5KW AND THE OTHER SHOWS | | | 10KW? | | | | | | 6)NOTE: PLEASE SEE ELECTRICAL SYSTEMS | | | FOR BLDG ELECTRICAL SEEMS TO ALL BE | | | 120/208V, HOWEVER, PLEASE SEE ELECTRICAL | | | PANELS FOR UNIT SHOW 120/240V? | | | PLEASE ADJUST. | | | | | | 7)NOTE: PLEASE SEE MISSING SD IN L/WD-3. | | | | | | 8)NOTE: PLEASE SEE SOME MISSING RECEPTS | | | PER 210.52, 210.52C1, AS NOTED ON | | | PREVIOUS COMMENT. | | | | | | 9)NOTE: PLEASE SEE MISSING SHEETS FROM | | | SETS. E-9,10 AND 19. PLEASE SEE ONNLY | | | OLD/VOIDED SHEETS ARE IN SETS. | | | UNABLE TO REVIEW THESE PAGES AT THIS | | | TIME. | | | | | | 10)NOTE:PLEASE VERIFY AIC RATINGS SHOWN | | | ON PANEL SCHEDULESAND RISER. PLEASE | | | SEE 110K ETC. | | | THIS IS ONLY A NOTE AND SOME AIC RATINGS | | | SEEM A LITTLE HIGH, HOWEVER THESE ARE | | | PERMITTED. HOWEVER, IF SHOWN ON PLANS, | | | THEN THESE WILL BE REQUIRED TO BE | | | INSTALLED. | | | | | | 11)NOTE: PLEASE SEE FPL VAULT IS NOT | | | PERMITTED TO HAVE ANY ELECTRICAL IN ROOM | | | WHICH IS PART OF BLDG ELECTRICAL . | | | PLEASE SEE LTS, RECEPTS MUST BE REMOVED | | | FROM PLANS. | | | AS PER CONVERSATION WITH BILL HARTIGAN | | | FROM FPL. | | | PLEASE ALSO BE SURE TO CONTRACT FPL FOR | | | SIZING OF FPL VAULT AND ANY OTHER | | | REQUIREMENTS THERE MAY BE. | | | | | | 12)NOTE: PLEASE SEE SOME ELEVATION | | | DRAWINGS SHOW "OLD METER"?? | | | PLEASE CLARIFY? | | | 215.5 | | | | | | 13)NOTE: PLEASE SEE NOTES PERTAINING TO | | | "SIGNS FOR ELEVATORS" MENTIONS HEIGHT | | | REQUIREMENTS FOR LETTERING TO BE MIN OF | | | 1/8", PLEASE CLARIFY THIS. PLEASE SEE | | | MIN SIGNAGE IN NFPA, LS 101, NEC ETC, | | | ALL MENTIONS A MIN OF 1" LETTERS ON A | | | CONTRASTING BACKGROUND. | | | | | | 14)NOTE:PLEASE SEE PANEL HDP-3, WHICH | | | SHOWS A FUTURE POOL PANEL, YET RISER | | | SHOWS PANEL INSTALLED AT THIS TIME . | | | PLEASE ALSO SEE ALL PLANS INDICATE POOL | | | BEING BUILT WITH BLDG. PLEASE SEE EVEN | | | THOUGH POOL IS REQUIRED UNDER SEPARATE | | | PERMIT, ALL ELECTRICAL INFORMATION IS | | | ALSO REQUIRED ON BASE BLDG PLANS. | | | PLEASE PROVIDE INFORMATION FOR NEW PANEL | | | HP. PLEASE PROVIDE FEED, OCP, CONDUIT | | | ETC. | | | | | | 15)NOTE: PLEASE CLARIFY TWO SEPARATE | | | FEED TO SINGLE RTU'S. RISER SHOWS | | | 4-RTU'S, HOWEVER, RISER SHOWS POWER | | | COMING FROM TWO DIFFERENT FEEDS AND | | | EQUIPMENT. | | | | | | 16)NOTE: PLEASE SEE SPECS AND CORRELATE | | | WITH PLANS, THIS WAS NOTED ON PREVIOUS | | | COMMENT ALSO. | | | | | | 17)NOTE: PLEASE SEE DESIGN FOR FIRE PUMP | | | HAS NOW COMPLETELY CHANGED. PLEASE SEE | | | FIRE PUMP IS NOW BEING SHOWN BEING FED | | | FROM FPL, DIRECTLY, WHICH IS FINE, | | | HOWEVER FIRE PUMP IS NOW BEING FED FROM | | | EDP? | | | PLEASE SEE IF EDP IS SHUT DOWN IN BLDG | | | DUE TO FIRE, THE FIRE PUMP WOULD NOW BE | | | DISABLED DUE TO FEED COMING FROM EDP. | | | PLEASE SEE 695 . | | | PLEASE SEE ATS AT GENERATOR WOULD BE | | | REQUIRED TO HAVE A MAIN. PLEASE SEE | | | RISER ALSO INDICATES ATS AT GENERATOR | | | HAVING A FEED DIRECTLY INTO FPL VAULT?? | | | RISER SHOWS TWO FEEDS FROM FPL TO FIRE | | | PUMP AND EDP. | | | PLEASE SEE THERE ARE TOO MANY ISSUES | | | WITH THE WAY THE RISER SHOWS FEEDS TO | | | TYPE IN A RESPONSE/PLANS REVIEW NOTES. | | | | | | PLEASE CALL OR MEET TO GO OVER THIS | | | SCENERIO. | | | | | | 18)NOTE: PLEASE SEE RISER INDICATES ALL | | | FED INTO FPL VAULT AS OVER HEAD. PLEASE | | | SEE AS PER NEC AND LOCAL AMENDMENTS, NO | | | MORE THAN 8' OF "UNPROTECTED" CONDUCTORS | | | MAY BE INSIDE BLDG. 230.70 | | | PLEASE SEE THESE APPEAR THEY MAY BE | | | REQUIRED TO BE "INCASED IN CONCRETE" | | | ETC. | | | | | | 19)NOTE: PLEASE SEE ALL MAINS ARE SHOWN | | | AS HAVING A SHUNT TRIP, PLEASE CLARIFY | | | IF THESE MAINS ALSO CONTAIN A MANUAL | | | MEANS OF DISC LOCATED ON THE OUTSIDE. | | | 230.76,230.79 | | | | | | 20)NOTE: PLEASE SEE ALL MAINS ARE SHOWN | | | WITH GROUND FAULT PROTECTION ?? | | | PLEASE SEE 230.95,240.13THIS IS ONLY A | | | NOTE: | | | | | | 21)NOTE: PLEASE SEE 424.3B, OCP FOR | | | AHU'S INT UNITS IS THE ONLY THING WHICH | | | IS TO BE AT 125%, LOAD CALCS DO NOT HAVE | | | TO BE SHOWN AT 125%. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | 2005-04-14 00:00:00 | IN FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-23 |
Time |
15:04 |
Rev Time |
12.00 |
| Received By |
dpalmer |
Date |
2004-11-18 |
Time |
20:01 |
Sent To |
|
|
| Notes |
| 2004-11-23 00:00:00 | *************** UNSAT ***************** | | | | | | PLEASE SEE THE FOLLOWING COMMENTS CAN | | | ONLY BE BASED ON PLANS SUBMITTED. | | | DUE TO PLANS AND SUBMITTAL PACKAGE NOT | | | BEING COMPLETE AT THE TIME OF REVIEW, | | | THERE MAY BE ADDITIONAL COMMENTS WHEN | | | PLANS ARE RE-SUBMITTED. | | | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002 FOR | | | MISSING REQUIRED INFORMATION ON TITLE | | | BLOCK. | | | PLEASE ALSO SEE FS 471.023 FOR | | | REQUIREMENTS. | | | PLEASE ALSO SEE FS 471.025 FOR "RAISED" | | | SEAL TO BE CLEAR AND VISABLE WITH ALL | | | INFORMATION ON SEAL. | | | PLEASE PROVIDE A SIGNED,DATED AND SEALED | | | NOTORIZED LETTER FOR VERIFICATION OF | | | LEGAL SIGNATURE. PLANS APPEAR TO BE | | | SIGNED WITH INITIALS WHICH ARE NOT | | | PERMITTED UNDER FS 471.025. | | | IF INDEED LEGAL SIGNATURE, PLEASE | | | PROVIDE LETTER FOR "SIGNATURE FILE" FOR | | | FUTURE REFERENCE. | | | THIS IS REQUIRED FOR ALL SHEETS AND FOR | | | ALL TRADES WHEATHER OR NOT COMMENT IS | | | MADE BY OTHER REVIEWER(S). | | | | | | 2)NOTE:PLEASE SEE 110.26 FOR ALL | | | ELECTRICAL ROOMS AND DOOR REQUIREMENTS. | | | PLEASE REVISE PLANS TO SHOW OUTWARD | | | SWING AND PROVIDE NOTE FOR PANIC | | | HARDWARE ETC. | | | ** PLEASE SEE ANY EGRESSISSUE THAT MAY | | | ARISE WITH DOOR SWING** THIS IS ONLY A | | | NOTE:. | | | | | | 3)NOTE: PLEASE SEE THERE ARE NUMEROUS | | | LOCATIONS WHERE "COMMON AREA" LIGHTING | | | IS BEING CONTROLLED BY A WALL SWITCH. | | | THIS WOULD CREATE A SAFTEY ISSUE DUE TO | | | LTS IN ARE BEING TURNED OUT WHEN PERSONS | | | ARE IN MODE OF EGRESS. | | | *TYP* LTS IN COMMON AREAS ARE HARDWIRED | | | TO SYSTEMS ELECTRICAL LIKE MANY OF THE | | | OTHER COMMONAREAS? | | | LS 101 5-8 | | | | | | 4)NOTE: PLEASE SEE SOME ELEVATOR LOBBY | | | AREAS WHICH PLASN DO NOT CONTAIN ANY | | | LIGHTING? ELEV 4 LOBBY) | | | | | | 5)NOTE: PLEASE SEE 620.24ABC FOR MISSING | | | REQUIRED LTS/RECEPTS ETC. | | | | | | 6)NOTE: PLEASE SEE RECEPT SPACING IN | | | NUMEROUS UNITS. PER 210.52 | | | PLEASE SEE MANY ARE REDLINED AT | | | LOCATIONS REQUIRED ON ONE SET OF PLANS | | | SUBMITTED. PER 2',6',12' RULE. | | | PLEASE ALSO SEE MEZZ AREAS. | | | | | | 7)NOTE: PLEASE SHOW CIRCUITING ON PLANS | | | FOR ALL ELECTRICAL DEVICES SHOWN AND | | | CORRELATE WITH THE SUBMITTED PANEL | | | SCHEDULES. (SD'S ETC.) | | | | | | 8)NOTE: PLEASE SEE CIRCUITING OF SD'S ON | | | BATH/KIT LT CIRCUITS WHICH IS OK, | | | HOWEVER BATH /KIT LIGHTS WILL THEN | | | REQUIRE ARC-FAULT PROTECTION. | | | 2002 NEC 210.12 | | | | | | 9)NOTE: PLEASE SEE SOME CONDENSING UNITS | | | SHOWN IN GARAGE ON E-5, PLEASE SHOW ALL | | | DISC'S/CIRCUITING PER 440.11 | | | PLEASE ALSO INCLUDE REQUIRED GFI PER | | | 210.63 | | | | | | 10)NOTE: PLEASE SEE 210.52H FOR "HALL" | | | AREA RECEPT SPACING. SOME UNITS UNITS ON | | | TYPICAL FLRS. | | | | | | 11)NOTE: PLEASE SEE 700.16 FOR ALL | | | ELECTRICAL/ELEVATOR/FIRE COMMAND RMS | | | ETC | | | FOR LIGHTING REQUIREMENTS. | | | | | | 12)NOTE: PLEASE PROVIDE ROOM | | | DESIGNATIONS ON PLANS. | | | | | | 13)NOTE: PLEASE SEE LOCATIONS OF SD'S | | | ARE TO BE INSTALLED PER NFPA-72 | | | 8-1.4.1.6.2 AND 8-1.4.2 | | | 3' OF BATH RM DOORS ETC. PLEASE REVISE | | | NOTE ON E-19 WHICH MENTIONS SD'S OK TO | | | INSTALL W/IN 20' OF COOKING APPLIANCE. | | | THIS IS ONLY PERMITTED WITH EXCEPTIONS | | | LISTED. | | | | | | 14)NOTE: PLEASE SEE SOME MISSING GFI | | | RECEPTS REQUIRED IN SOME UNITS PER | | | 210.52C1, GFI PER 210.8A6 | | | | | | 15)NOTE: PLEASE SEE CIRCUITING FOR | | | DINING ROOM/AREA RECEPTS. PLEASE | | | DESIGNATE AREA/RM. PLEASE SEE 210.52B1 | | | | | | 16)NOTE: PLEASE SEE UPPER ROOF LEVELS. | | | PLEASE COMPLETE ELECTRICAL PLANS AS SOME | | | OF THESE AREAS ON PLANS DO NOT INDICATE | | | ANY ELECTRICAL.; LTS, RECEPTS ETC. | | | RECEPTS REQUIRED W/IN 20' OF POOL. | | | 680.22A1 | | | | | | 17)NOTE: PLEASE SEE ALL COND UNITS ON | | | UPPER ROOF LEVEL. PLEASE INDICATE ALL | | | REQUIRED DISCONNECTS PER 440.11 AND | | | GFI'S PER 210.63,210.8 | | | | | | 18)NOTE:PLEASE SEE MISSING EGRESS | | | LIGHTING FOR STAIRS ON ROOF PLANS. | | | LS101 5-8. PLEASE SEE POSSIBLE COMMENTS | | | FROM FIRE/BLDG REVIEW FOR THIS. | | | | | | 19)NOTE: PLEASE CORRELATE METER CENTER | | | MAINS ON RISER/ PLANS / ELEVATION | | | RISER. | | | PLANS INDICATE 700A MAINS, HOWEVER OTHER | | | AREAS INDICATE 1000A? | | | 215.5 | | | | | | 20)NOTE: PLEASE 240.4C FOR SIZING OF ALL | | | CONDUCTORS FOR DEVICES RATED OVER | | | 800A'S | | | PLEASE ALSO SEE 310.16,110.14 FOR RATING | | | OF CONDUCTORS AND TEMP LIMITATIONS. | | | | | | 21)NOTE: PLEASE CORRELATE # OF | | | CONDUCTORSIN THE # OF SETS AND # OF | | | CONDUITS ON E-17 | | | | | | 22)NOTE: PLEASE SEE "SWITCH GEAR RM", | | | PLEASE SHOW LAYOUT OF ROOM WITH LOCATION | | | OF ALL ELECTRICAL EQUIPMENT AND MAINS. | | | | | | 23)NOTE: PLEASE CORRELATE RISER DIAGR | | | AND PLANS WITH ELECTRICAL EQUIPMENT AND | | | WHICH LEVEL EQUIPMENT IS ON. | | | | | | 24)NOTE: PLEASE SEE MAIN FOR EM POWER | | | DISTRIBUTION IS REQUIRED TO BE GROUPED | | | CLOSER THAN SHOWN ON PLANS. TRAVEL | | | DISTANCE AND PLANS INDICATING THESE | | | MAINS AND SHUT-DOWNS ON DIFFERENST | | | LEVELS AND XX FEET APART WILL NOT BE | | | APPROVED BY FIRE MARSHAL'S OFFICE OR | | | ELECTRICAL PLAN REVIEW. | | | PLEASE SEE 230.72,230.70,230.76,230.79 | | | PLEASE BE AWARE "SHUNT-TRIPS" ARE NOT AN | | | ACCEPTABLE METHOD FOR COMPLIANCE. | | | | | | 25)NOTE: PLEASE SEE E-6, PLEASE IDENTIFY | | | WHAT APPEARS TO BE TWO PIECES OF EM | | | ELECTRICAL EQUIPMENT. | | | 215.5 | | | | | | 26)NOTE:PLEASE SEE PANEL SCHEDULES WERE | | | SUBMITTED FOR MAINS 1,2,3 ON E-17, BUT | | | NONE FOR MAINS 4,5 ? PLEASE SHOW | | | 215.5 | | | | | | 27)NOTE:PLEASE SEE RISER DIAGRAM: PLEASE | | | SEE OCP/LOCKED ROTOR FOR FIRE PUMP IS | | | SHOWN TO BE A MIN OF 1085A'S, YET FUSES | | | ARE INDICATED AS 1000A'S?? PLEASE SEE | | | 695.4B1 | | | | | | 28)NOTE: PLEASE SEE RISER DIAGRAM | | | INDICATES FIRE PUMP FEED COMING FROM FPL | | | AND METER RM? PLEASE VERIFY WHICH ONE? | | | AND WHERE FEED IS COMING FROM. | | | PLEASE SUBMIT COMPLETE SPECS ON FIRE | | | PUMP AND FIRE PUMP CONTROLLER. | | | PLEASE BE SURE THIS IS ALL A LISTED | | | UNIT. | | | PLEASE BE SURE IT CONTAINS A MAN MEANS | | | OF DISC AND RATED FOR LOAD SERVED AND | | | MEETS 110.27, 230.76,230.79 | | | PLEASE ALSO SEE VOLTAGES FOR LOCK ROTOR | | | IN TABLE.430.151 | | | | | | 29)NOTE: PLEASE SUBMIT COMPLETE SPECS | | | FOR GENERATOR AND TRANSFER SWITCH. | | | PLEASE CORRELATE PLANS WITH SUBMITTALS. | | | 215.5 | | | | | | 30)NOTE: PLEASE CORRELATE RISER, RISER | | | EQUIPMENT SCHEDULE AND GENERATOR NOTES | | | FOR TRANSFER SWITCH SIZE AND VOLTAGE. | | | ONE SHOWS 1200A, THE OTHER 3500A ETC. | | | | | | 31)NOTE: PLEASE CORRELATE RISER WITH | | | GENERATOR NOTES FOR GENERATOR, SHOWS TWO | | | DIFFERENT SIZES ETC.875KVA , 1200 KVA | | | ETC | | | PLEASE SEE PLANS ARE CALLING FOR TWO | | | DIFFERENT VOLTAGES FOR SAME EQUIPMNET? | | | 215.5 | | | | | | 32)NOTE: PLEASE SEE ELECTRICAL RISER | | | DIAGRAM EQUIPMENT SCHEDULE NOTES: ONLY | | | SHOWS NOTES 1-5 YET PLANS/RISER DIAGRAM | | | SHOWS MANY MORE AREAS LABELED TO SEE | | | NOTES ON EQUIPMENT SCHEDULE. #'S 8,9,18 | | | ETC ETC. | | | | | | 33)NOTE: PLEASE LABEL EDP ON RISER WITH | | | EQUIPMENT SCHEDULE NOTES.; | | | 215.5 | | | | | | 34)NOTE: PLEASE SEE ELEVATOR DISC/ | | | EQUIPMENT ON RISER WHICH IS SHOWN ON THE | | | ROOF AND COMING DIRECTLY FROM TANSFORMER | | | VAULT??? MAINS? GROUPING ? OVERCURRENT- | | | PROTECTION ETC. | | | 230.72,230.70,230.76,.230.79,215.5 | | | | | | 35)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTORS ON RISER AND OTHER | | | AREAS WHICH ARE REQUIRED PER | | | 250.110,250.24, SIZED PER 250.122 | | | | | | 36)NOTE: PLEASE SEE 2002 NEC FOR | | | GROUNDING ELECTRODE SYSTEM. 250.50, | | | 250.66. | | | | | | 37)NOTE: PLEASE SEE THERE ARE NUMEROUS | | | LOCATIONS ON PLANS WHICH GIVE REFERENCE | | | TO CODES FROM 1996/1999 NEC. | | | PLEASE SEE WE ARE UNDER THE 2002 NEC. | | | JUST A NOTE: 2002 NEC WAS ADOPTED BY THE | | | STATE 7/1/2003 | | | PLEASE ADJUST ALL LOCATION ON PLANS. | | | | | | 38)NOTE: PLEASE SEE PLANS REFERENCE THE | | | SOUTH FLORIDA BLDG CODE. | | | PLEASE SEE WE ARE UNDER 2001 FBC WITH | | | REVISIONS. | | | | | | 39)NOTE: PLEASE SEE LOCAL AMENDMENST FOR | | | COLOR CODING 215.5 FOR 277/480V SYSTEMS | | | ETC. | | | | | | 40)NOTE: PLEASE SEE PLANS HAVE BEEN | | | REDLINED WITH MOST OF THE ABOVE ITEMS | | | AND AREAS OF COMMENTS. | | | | | | 41)NOTE: PLEASE SEE ANY POSSIBLE | | | COMMENTS FROM OTHER REVIEWER(S) WHICH | | | MAY HAVE AN AFFECT ON ELECTRICAL PLANS. | | | | | | 42)NOTE: PLEASE REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | | | | 43)NOTE: PLEASE SEE BLDG REVIEW | | | COMMENTS: THIS IS A THRESHOLD BLDG AND | | | THREE SETS OF PLANS ARE REQUIRED. | | | | | | | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | 2004-11-18 00:00:00 | IN ELECTRICAL FOR REVIEW. | | | NOTES TO FOLLOW. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2005-07-01 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-07-01 |
Time |
09:39 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2005-07-01 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2005-07-01 00:00:00 | PASSED WITH PROVISOS: | | | | | | 1. PLEASE NOTE THAT ANY WORK WITHIN | | | PUBLIC R.O.W REQUIRES A PERMIT FROM | | | PUBLIC UTILITIES AND ENGINEERING PRIOR | | | TO BEGINNING OF SUCH WORK, 494-1086. | | | | | | 2. POLLUTION / EROSION CONTROL DEVICES | | | SHALL BE IN PLACE PRIOR TO BEGINNING ANY | | | CONSTRUCTION ACTIVITIES.THE DEVICES | | | MUST BE MAINTAINED AND MONITORED | | | THROUGHOUT THE CONSTRUCTION PERIOD. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2005-03-23 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-03-23 |
Time |
14:04 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2005-03-23 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2005-03-23 00:00:00 | FAILED: | | | | | | 1. PROPOSED SITE MUST BE DESIGNED FOR | | | WATER QUALITY AND DRAINAGE PER CITY OF | | | WEST PALM BEACH' CRITERIA AND | | | REQUIREMENTS.PLEASE SUBMIT CALCULATION | | | FOR OUR REVIEW AND APPROVAL. | | | 2. PLEASE VERIFY THE PROPOSED INVERT | | | ELEVATIONS OF THE DRAINAGE SYS. WITH | | | RELATION TO THE GARAGE FINISH FLOOR | | | ELEVATIONS. | | | 3. CIVIL PLANS SHOWS RPZS AND DDCA | | | INSIDE THE BUILDING, MECHANICAL SHOWS | | | THE ASSEMBLIES OUTSIDE THE BUILDING, | | | PLEASE COORDINATE. | | | 4. CIVIL PLANS MUST BE REVIEWED AND | | | APPROVED BY THE PUBLIC UTILITIES AND | | | ENGINEERING FOR ALL THE CONNECTIONS TO | | | THE CITY SERVICES AND FOR THE LOCATIONS | | | OF THE METERS AND BACKFLOWS.PLEASE | | | CONTACT MANNY GONZALEZ AT 494-1085. | | | 5. FOR THE CITY' STANDARDS AND DETAILS | | | CONTACT MANNY GONZALEZ AT 494-1085. | | | 6. CIVIL PLAN DOES SHOW THE | | | RECONSTRUCTION OF THE SIDEWALKS LIMITS | | | AND STREET SCAPING AND/OR ITS TYPE ALONG | | | THE ROSEMARY AVE. AND BANYAN STREET. | | | PLEASE COORDINATE WITH THE LANDSCAPE | | | PLANS. | | | 7. PLEASE VERIFY THE ADEQUACY OF THE | | | EXISTING 14' ALLEY FOR THE TRAFFIC BEING | | | GENERATED BY THE FUTURE RESIDENTS TO | | | ACCESS THE PARKING GARAGE. | | | 8. ANY IMPROVEMENT IN 14' ALLEY MUST BE | | | COORDINATED AND APPROVED BY THE CITY WPB | | | PUBLIC UTILITIES AND ENGINEERING. | | | 9. IS THE ALLEY GOING TO BE RE-SURFACED? | | | WHO WILL BE DOING THAT? | | | 10. PLEASE NOTE THAT ANY WORK WITHIN THE | | | PUBLIC R.O.W WILL REQUIRE A SEPARATE | | | PERMIT FROM PUBLIC UTILITIES AND | | | ENGINEERING, PLEASE SUBMIT M.O.T AT THE | | | TIME OF APPLICATION, CONTACT 494-1086, | | | WINDEL PALMER. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2004-11-10 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-11-10 |
Time |
14:50 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-11-10 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2004-11-10 00:00:00 | FAILED: | | | | | | 1.PROPOSED SITE MUST BE DESIGNED FOR | | | WATER QUALITY AND DRAINAGE PER CITY OF | | | WEST PALM BEACH' CRITERIA AND | | | REQUIREMENTS, PLEASE SUBMIT | | | CALCULATIONS | | | FOR OUR REVIEW AND APPROVAL. | | | 2.CIVIL PLANS MUST BE REVIEWED FOR ALL | | | THE CONNECTIONS TO THE CITY SERVICES BY | | | THE PUBLIC UTILITIES AND ENGINEERING, | | | ATT; MANNY GONZALEZ 494-1085. | | | 3. CITY' STANDARDS AND DETAILS MAY BE | | | OBTAINED FROM PUBLIC UTILITIES AND | | | ENGINEERING, ATT;MANNY GONZALEZ | | | 494-1085. | | | 3.PLEASE SHOW SIZE, TYPE OF PIPE FOR | | | ROOF DRAINS AND ALSO DETAILS FOR | | | CONNECTION TO THE EXISTING STRUCTURES. | | | 4.STEERT SCAPING, BANYAN & ROSEMARY | | | MUST BE APPROVED BY THE PLANNING | | | DEPARTMENT, 822-1435. | | | 5.SITE PLAN PREPARED BY THE ARCHITECT | | | SHOWS PAVERS FOR THE SIDEWALK, CIVIL | | | SHOWS CONCRETE, PLEASE VERIFY. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2005-08-05 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-08-05 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-08-05 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2005-08-05 00:00:00 | ******DENIED****** | | | | | | PLEASE NOTE THAT COMMENTS FROM THE LAST | | | FIRE REVIEW DON'T APPEAR TO HAVE BEEN | | | ADDRESSED. AS INDICATED IN LAST REVIEW, | | | A RESPONSE LETTER ILLUSTRATING THE | | | CORRESPONDING SHEET NUMBER WOULD HELP | | | EXPEDITE THE PLAN REVIEW PROCESS. THANK | | | YOU IN ADVANCE FOR YOUR CONSIDERATION | | | REGARDING THIS MATTER. | | | | | | 1) FIRE PROTECTION SHEETS ARE MISSING | | | WITH THIS RESUBMITTAL. PLEASE KEEP ALL | | | APPROPRIATE SHEETS ATTACHED FOR EACH | | | REVIEW. PLEASE SEE COMMENT #1 FROM LAST | | | REVIEW. | | | | | | 2) ALL SHAFTS THAT ARE LARGE ENOUGH FOR | | | PERSONS TO FALL INTO MUST BE MARKED | | | SHAFTWAY IN 6" LETTERS. | | | | | | 3) PLEASE INDICATED PRESCRIPTIVE | | | STRENGTH REQUIREMENTS FOR HANDRAILS AND | | | GUARDS. | | | | | | 4) PLEASE SUBMIT OCCUPANT LOAD | | | CALCULATIONS FOR THE POOL DECK AND | | | PATIO. | | | | | | 5) ALL DOOR SWINGS SERVING AREAS OR | | | ROOMS WITH OCCUPANT LOADS GREATER THAN | | | 50 SHALL SWING IN THE DIRECTION OF | | | TRAVEL. | | | | | | 6) PLEASE INDICATE ON PLANS THAT ALL | | | SMOKE DETECTORS SHALL BE NO CLOSER THAN | | | 3' FROM AC DIFFUSERS. | | | | | | 7) PLEASE ILLUSTRATE VERIFICATION | | | REGARDING STANDBY POWER REQUIREMENTS. | | | | | | 8) ELEVATOR WARNING SIGNS ARE REQUIRED. | | | PLEASE INDICATE WITH NOTE ON DRAWINGS. | | | | | | 9) EXITS SHALL BE READILY VISIBLE FROM | | | ANY DIRECTION WITHIN EXIT ACCESS. | | | | | | 10) PLEASE SHOW ON PLANS THAT THE VOICE | | | EVACUATION MESSAGE SHALL COMPLY WITH THE | | | REQUIREMENTS OF NFPA 72, AND NFPA 101, | | | SECTION 9.6.3. | | | | | | WHEN RESUBMITTING PLANS FOR REVIEW, IT | | | IS RECOMMENDED THAT EACH COMMENT BE | | | ADDRESSED BY LETTER INDICATING THE SHEET | | | NUMBER WHERE APPLICABLE. | | | | | | | | | MIKE WENNERGREN, CAPTAIN | | | WPBFR(561) 804-4756 | | | PLAN REVIEW(561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2005-05-02 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-05-02 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-05-02 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2005-05-02 00:00:00 | 1) COMMENTS # 2,9,10,12,15,30,37,41 HAVE | | | APPARENTLY BEEN ADDRESSED ON THE FIRE | | | PROTECTION SHEETS. ALL SHEETS HAVE BEEN | | | VOIDED. PLEASE PROVIDE CURRENT FIRE | | | PROTECTION DRAWINGS FOR REVIEW. INDICATE | | | YOUR RESPONSES WITH SHEET NUMBERS AND | | | RERVISION CLOUDS. | | | | | | 2) PLEASE INDICATE THE SHEET NUMBER WITH | | | YOUR RESPONSE REGARDING THE MARKING OF | | | SHAFTS. COMMENT #8 | | | | | | 3) PLEASE RESPOND TO COMMENT REGARDING | | | PRESCRIPTIVE HANDRAIL AND GUARDRAIL | | | STRENGTHS WITH REVISION CLOUD AND SHEET | | | NUMBER. COMMENT #13 | | | | | | 4) PLEASE INDICATE OCCUPANT LOAD | | | CALCULATIONS FOR THE POOL DECK AND | | | COMMON PATIO WITH REVISION CLOUD AND | | | SHEET NUMBER. COMMENT #14 | | | | | | 5) ALL DOOR SWINGS SHALL BE IN THE | | | DIRECTION OF TRAVEL WHEN SERVING A ROOM | | | OR AREA WITH OCCUPANT LOAD OF GREATER | | | THAN 50. COMMENT #26 | | | | | | 6) PLEASE INDICATE THE SHEET NUMBER | | | REGARDING THE SLIP RESISTANCE OF | | | WALKWAY. COMMENT #27 | | | | | | 7) PLEASE INDICATE THE SHEET NUMBER | | | REGARDING MINIMUM DISTANCE BETWEEN SMOKE | | | DETECTORS AND AC DIFFUSERS. COMMENT #32 | | | | | | 8) PLEASE INDICATE SHEET NUMBER | | | REGARDING STANDBY POWER REQUIREMENTS. | | | COMMENT #34 | | | | | | 9) PLEASE INDICATE SHEET NUMBER | | | REGARDING ELEVATOR WARNING SIGNS. | | | COMMENT #35 | | | | | | 10) PLEASE PROVIDE FURTHER EXPLANATION | | | REGARDING MEANS OF EGRESS THROUGH | | | PARKING SPACES. HOW CAN THIS BE | | | MAINTAINED ACCESSABLE AND FREE OF | | | OBSTRUCTIONS AT ALL TIMES? COMMENT #36 | | | | | | 11) EXITS SHALL BE READILLY VISIBLE FROM | | | ANY DIRECTION OF EXIT ACCESS. COMMENT | | | #38 | | | | | | 12) VOICE EVACUATION MESSAGE SHALL | | | COMPLY WITH NFPA 72 AND NFPA 101, | | | SECTION 9.6.3. COMMENT #40 | | | | | | | | | PLEASE ADDRESS COMMENTS WITH SHEET | | | NUMBERS AND REVISION CLOUDS TO ASSIST IN | | | EXPEDITING THIS PROCESS. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 835-2910 OR 805-6722 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-12-15 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-12-15 |
Time |
07:19 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-12-15 |
Time |
07:19 |
Sent To |
|
|
| Notes |
| 2004-12-15 00:00:00 | 1) PLEASE INDICATE LOCATION OF FIRE | | | COMMAND CENTER ON PLANS. | | | | | | 2) KNOX-BOXES WILL BE REQUIRED. | | | | | | 3) BUILDING IS TO MEET HIGH-RISE | | | REQUIREMENTS OF THE APPLICABLE | | | BUILDING AND FIRE CODES. | | | | | | 4) A TWO-HOUR FIRE SEPARATION IS | | | REQUIRED BETWEEN THE PARKING AND OTHER | | | AREAS OF THE BUILDING. | | | | | | 5) S-3 DOOR NEAR LOADING ZONE 2. PLEASE | | | EXPLAIN. | | | | | | 6) S-2 DOOR NEAR ALLEY. PLEASE EXPLAIN. | | | | | | 7) TACTILE SIGNAGE REQUIRED AT EXIT | | | DOORS. | | | | | | 8) ALL SHAFTS THAT ARE LARGE ENOUGH | | | FOR PERSONS TO FALL INTO MUST | | | BE MARKED SHAFTWAY IN 6" LETTERS. | | | | | | 9) THE FIRE ALARM SYSTEM MUST MEET | | | THE REQUIREMENTS FOR CENTRAL STATION | | | SERVICE. | | | | | | 10) TWO FIRE DEPARTMENT CONNECTIONS | | | ARE REQUIRED FOR THE BUILDING SINCE | | | IT IS A HIGH-RISE BUILDING. | | | | | | 11) ALL NEW STAIRS AND RAMPS SHALL | | | HAVE HANDRAILS ON BOTH SIDES. | | | | | | 12) LOCKING KNOX-BOX CAPS ARE REQUIRED | | | ON THE FIRE DEPARTMENT CONNECTIONS. | | | | | | 13) PLEASE PROVIDE PRESCRIPTIVE | | | STRENGTH REQUIREMENTS FOR HANDRAILS | | | AND GUARDRAILS. | | | | | | 14) PLEASE PROVIDE OCCUPANT LOADS | | | FOR POOL DECK AND COMMON PATIO. | | | | | | 15) PLEASE DISPLAY ALL EXISTING OR | | | NEW FIRE HYDRANTS ON SITE. | | | | | | 16) PARKING SPACES SURROUND STAIR # 1 | | | ON PAGE A-3. PLEASE EXPLAIN ACCESS. | | | | | | 17) PARKING SPACES SURROUND STAIR # 3 | | | ON PAGE A-4. PLEASE EXPLAIN ACCESS. | | | | | | 18) BUILDING LOCATED IN FIRE LIMITS. | | | CERTAIN RESTRICTIONS APPLY. PLEASE | | | SEE APPENDIX F, LOCAL AMENDMENTS. | | | | | | 19) EXIT SIGN PLACEMENT SHALL NOT | | | EXCEED 100 FEET. | | | | | | 20) ENSURE THAT ALL DOOR SWINGS ARE | | | INCORRECT. | | | | | | 21) THE DOOR APPEARS TO BE MISSING | | | FROM STAIR # 1ON PAGE A-7. | | | | | | 22) PLEASE EXPLAIN EXITING FROM | | | MEZZANINE LEVEL. | | | | | | 23) PLEASE PROVIDE INTERIOR FINISH | | | CLASSIFICATIONS FOR WALLS AND CEILINGS. | | | | | | 24) SIGNS REQUIRED IN STAIRWELLS | | | INDICATING TOP, BOTTOM, FLOOR NUMBER, | | | ROOF ACCESS, AND THE IDENTITY. | | | | | | 25) WOOD TRELLIS NOTED ON ROOF | | | TERRACE. AGAIN LOCATED IN FIRE LIMITS. | | | | | | 26) ARE THE DOORS AT THE MAIN LOBBY | | | ROOF TERRACE SWINGING IN THE PROPER | | | DIRECTION. | | | | | | 27) IS THE WALKWAY TO THE EXITS ON ROOF | | | TERRACE SLIP RESISTANT. | | | | | | 28) BUILDING ADDRESS REQUIRED. A MINIMUM | | | | | | OF AT LEAST 6" HIGH NUMBERS ARE | | | REQUIRED. | | | | | | 29) CANVAS AWNINGS REQUIRED TO BE | | | FLAME RETARDANT. | | | | | | 30) PLEASE DISPLAY FIRE SPRINKLER | | | LOCATIONS IN TRASH CHUTE SECTION. | | | | | | 31) SMOKE DETECTORS ARE REQUIRED ON | | | EVERY LEVEL OF RESIDENTIAL UNITS. | | | | | | 32) PLEASE INDICATE ON PLANS THAT | | | ALL SMOKE DETECTORS SHALL BE PLACED | | | NO CLOSER THAN THREE FEET FROM | | | AIR CONDITIONER DIFFUSERS. | | | | | | 33) PLEASE INDICATE STRETCHER | | | ACCESSIBLE | | | ELEVATORS IN THE BUILDING. | | | | | | 34) PLEASE VERIFY STANDBY POWER | | | REQUIREMENTS. | | | | | | 35) ELEVATOR WARNING SIGNS REQUIRED. | | | | | | 36) LIFE SAFETY ROUTES ON PAGE A-38 | | | ARE GOING THRU PARKING SPACES. PLEASE | | | EXPLAIN RATIONALE. | | | | | | 37) PLEASE PROVIDE WATER COLUMN | | | REQUIREMENTS FOR THE STAIRWELL | | | PRESSURIZATION SYSTEMS. | | | | | | 38) THERE ARE NOT ENOUGH EXIT SIGNS | | | SHOWN. | | | | | | 39) THE CORRIDORS NEED MORE EXIT | | | SIGNS. | | | | | | 40) PLEASE INDICATE WHAT THE VOICE | | | EVACUATION MESSAGE OF THE FIRE ALARM | | | SYSTEM WILL SAY. | | | | | | 41) ELECTRONIC SWITCHES REQUIRED ON | | | FIRE LINE BACKFLOW DEVICE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-11-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-15 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-15 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2005-11-15 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-11-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-14 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-14 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2005-11-14 00:00:00 | TO "DPALMER" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-29 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-29 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2005-07-01 00:00:00 | TO "COMM" BD#56/PLANS ON RACK/2 ROLLS | | 2005-06-29 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-21 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-21 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2005-03-21 00:00:00 | TO "COMM" BD#21/PLANS ON RACK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2004-12-15 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2004-11-05 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2004-11-05 00:00:00 | TO COMM BD#40 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-08-03 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-08-03 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2005-08-03 00:00:00 | PLAN DENIED | | | 1) EXHAUST DUCT AND DRYER DUCT TO BE | | | SUMITED AS ALTERNATIVE METERIALS AND | | | METHODS SECTION 301.4.2 FBC(M) | | | 2) PAGE M.4 REFER TO SECTION 501.3 | | | OUTDOOR DISCHARGE.CONDENSOR DISCHARGING | | | ON PATIOS. | | | 3) PAGE M.5 LOBBY PROVIDE FIRE | | | DAMPERS.PLEASE REFER TO SECTION 607.4 | | | FLOOR PENETRATION. | | | 4) PAGE M.5 DRYER VENT MUST BE 10FT. | | | FROM SF#1 | | | 5) REFER TO SECTION 504.6 CLOTHES DRYER | | | DUCT | | | 6) PLEASE PROVIDE INFORMATION ON RTU#2&3 | | | HOW ARE THEY GETTING FRESH AIR. | | | 7) PLEASE REFER TO SECTION 307.2.3 | | | AUXILIARY DRAIN PANS. | | | 8) COULD NOT FIND ANCERS FOR LAST REVIEW | | | | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-08-02 |
Time |
18:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-04-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-04-28 |
Time |
14:26 |
Rev Time |
6.00 |
| Received By |
pkrauss |
Date |
2005-04-28 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2005-04-28 00:00:00 | DENIED: | | | RESPONSE TO COMMENTS DATED 12-06-04: | | | COMMENT #1 - INDICATE MAKEUP AIR FOR THE | | | GARAGE EXHAUST.PLANS INDICATE | | | CALCULATIONS BUT DO NOT ANNOTATE OR | | | IDENTIFY HOW THE MAKE-UP AIR WILL BE | | | ACHIEVED. | | | | | | COMMENT #5 - PLAN SHEET M-3, DUCT | | | REDUCES IN RISER ONLY PLEASE CLARIFY. NO | | | CLARFICATION GIVEN AND DUCT SIZE DID NOT | | | CHANGE. | | | | | | COMMENT #9 - PLAN SHEET M-5, MAKE UP AIR | | | TO STAIR #1 WAS EXTENDED OUT BUT IS | | | STILL LOCATED AT THE GARAGE ENTRANCE. | | | PROVIDE ELEVATION OF THE FRESH AIR | | | INTAKE. | | | | | | COMMENT #12 - PROVIDE ELEVATION FOR THE | | | TERMINATION OF THE MUFFLER EXHAUST. | | | INDICATE DISTANCE FROM DOORS, WINDOWS | | | AND FRESH AIR INTAKES. | | | | | | COMMENT #13 - PROVIDE DETAIL AND | | | INFORMATION FOR THE FUEL PIPING AND | | | STORAGE TANK.PLEASE INDICATE WHERE | | | THIS ADDRESSED.INDICATE ON THE PLAN | | | LOCATION AND PIPE SIZING. | | | | | | COMMENT #16 - PLANS SHEETS M-3 THROUGH | | | M-6, STILL INDICATE THE DRYER & BATHROOM | | | EXHAUST IN THE RETURN AIR PLENUM.PER | | | 2001 FBC/M 601.3 EXHAUST DUCTS UNDER | | | POSTITIVE PRESSURE SALL NOT EXTEND INTO | | | OR PASS THROUGH PLENUMS. | | | | | | NEW COMMENTS: | | | 1.PLAN SHEET M-5 8"X 6" SUPPLY AIR | | | DUCT TO SECURITY OFFICE PENETRATES A 2 | | | HOUR RATED WALL.INDICATE COMPLIANCER | | | WITH 2001 FBC/M 607.1.3 #3 OR A FIRE | | | DAMPER WILL BE REQUIRED IN ACCORDANCE | | | WITH 2001 FBC/M 607.1.2. | | | | | | 2.PLAN SHEET M-11 THROUGH M-17 ARE | | | VOIDED BUT THE REPLACEMENT SHEETS WERE | | | NOT SUBMITTED.PLEASE CLARIFY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-06 |
Time |
17:32 |
Rev Time |
10.00 |
| Received By |
pkrauss |
Date |
2004-12-06 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2004-12-06 00:00:00 | DENIED: | | | 1.INDICATE HOW THE MAKE AIR FOR THE | | | GARAGE AREA WILL BE ACHIEVED. | | | | | | 2.PLAN SHEET M-1 THROUGH M-5, | | | ELEVATOR LOBBY SUPPLY AIR FROM ABOVE. | | | PLAN DOES NOT INDICATE ANY FIRE SMOKE | | | DAMPERS OR SHAFT.PER 2001 FBC(M)607.6, | | | SPECIFIC LOCATION OF FIRE DAMPERS & FIRE | | | DOORS ARE TO BE IDENTIFIED ON PLANS. | | | DETAIL OF FIRE DAMPERS & ACCESS DOORS | | | ARE ALSO REQUIRED. | | | | | | 3.PLEASE CLARIFY CONDENSING UNITS | | | LOCATED IN THE GARAGE AREA UNDER A ROOF | | | WITH NO CROSS VENTILATION. | | | | | | 4.M-1 ELEVATOR 2 & 3 LOBBY AREA FLEX | | | DUCT IS INDICATED AT THE RATED | | | PENETRATION. PER 2001 FBC(M)607.1.3 | | | EXCEPTION #3 ITEMS 1 THROUGH 4 SHALL | | | APPLY. | | | | | | 5.DUCT FOR THIS RISER REDUCES | | | DOWNWARD UNIT THE 1ST FLOOR AND THEN | | | INCREASES AGAIN, PLEASE CLARIFY. | | | | | | 6.M-2 EF5 & EF6 LOCATED AT THE FLOOR | | | LEVEL IN COMPACT CAR SPACES. | | | PROTECTION FROM DAMAGE REQUIRED PER | | | 2001 | | | FBC(M)303.4. | | | | | | 7.M-3 EF-7 IS LOCATED THAT THE | | | EXHAUST WILL BE RECIRCULATED BACK INTO | | | THE GARAGE ENTRANCE IN VIOLATION OF | | | 501.3. | | | | | | 8.M-3 EF-2,3,4,7, & 8 TERMINATING AT | | | THE ALLEY.PER 2001 FBC(M)705.1.THIS | | | APPLIES FOR OPENINGS INTO THE ALLEY | | | WAY. | | | | | | 9.M-5 SF-1 TO STAIR #1 MAKE-UP AIR | | | SHALL NOT BE TAKEN FROM PARKING AREAS, | | | STREETS OR ALLEYS PER 2001 | | | FBC(M)401.5.1. | | | | | | 10. M-6 EMERGENCY GENERATOR ROOM, A | | | FIRE | | | DAMPER IS INDICATED ON THE GENERATOR | | | INTAKE TO THE RADIATOR.PROVIDE THE | | | MANUFACTURER APPROVAL FOR THIS | | | APPLICATION. | | | | | | 11. M-6 PLEASE CLARIFY 6" MUFFLER | | | EXHAUST.NOTATION INDICATES 6" PIPE | | | UNDER SLAB.WILL THIS BE POURED INTO | | | THE SLAB BETWEEN THE FPL VAULT OR | | | PENETRATING THROUGH THE VAULT | | | UNDERGROUND? | | | | | | 12. PROVIDE ELEVATION FOR THE | | | TERMINATION OF THE MUFFLER EXHAUST. | | | PROVIDE DISTANCE FROM THE TERMINATION | | | TO | | | WINDOWS AND AIR INTAKES. | | | | | | 13. PROVIDE DETAIL FOR THE FILL PIPING | | | AND LOCATION OF THE FILL FOR THE FUEL | | | OIL TO THE GENERATOR. | | | | | | 14. M-3 THROUGH M-6 INDICATE DRYER & | | | TOILET EXHAUST TERMINATING INTO THE | | | GARAGE.PER 2001 FBC(M)501.3, EXHAUST | | | SHALL DISCHARGE OUTDOORS WHERE IT WILL | | | NOT CREATE A NUISANCE OR BE | | | RECIRCULATED | | | BY THE VENTILATION SYSTEM.EXHAUST | | | SHALL NOT BE DIRECTED ONTO WALKWAYS PER | | | 2001 FBC(M)401.5.2. | | | | | | 15. M-9 & M-10 INDICATE SHEET 9 OF 21 | | | AND 10 OF 21.THERE ARE ONLY 17 | | | MECHANICAL SHEETS. | | | | | | 16. RETURN AIR MISSING FROM UNIT | | | L/WB-4. | | | CERTIAN UNITS INDICATE RETURN AIR | | | PLENUMS.PER 2001 FBC(M)602.2.1, NO | | | COMBUSTIBLES ALLOWED ABOVE THE CEILING | | | IN THE RETURN AIR PLENUM. | | | | | | 17. M-11 INDICATE ACCESS AND CLEARANCES | | | FOR THE DUCTWORK INSTALLED UNDER THE | | | POOL.WILL THIS BE INSULATED? | | | | | | 18. M-11 & M-12 CONDENSING UNITS | | | LOCATED | | | ON THE ROOF OR ARE THEY ENCLOSED? | | | PLEASE NOTE, CONDENSING UNITS LOCATED | | | ON | | | THE ROOF SHALL COMPLY WITH 2001 FBC | | | 1511.7 FOR THE CLEARANCE BETWEEN THE | | | ROOF SURFACE AND THE BOTTOM OF THE | | | SUPPORT RAIL. | | | | | | 19. M-15 CORRIDOR PRESSURIZATION DETAIL | | | SHOWS 2" FIRE RATED CHASE.SHOULD THIS | | | READ 2 HOUR FIRE RATED CHASE? | | | | | | 20. M-16 RTU SCHEDULE INDICATES ALL | | | UNITS 60 TONS, THIS IS COMBINED.THE | | | PLAN INDICATES 2 EACH 10.5 TON & 2 EA | | | 13 | | | TON UNITS.DUCT SMOKE DETECTORS ARE | | | REQUIRED IN ACCORDANCE WITH 2001 | | | FBC(M)606. | | | | | | 21.M-16 SPECIFIC DRYERS INDICATED ON | | | DRYER SCHEDULE - SOME MODELS WOULD | | | STILL | | | EXCEED THE 25 FT MAXIMUM REQUIREMENT. | | | SPECIFIC DRYERS ARE TO BE INSTALLED FOR | | | FINAL INSPECTION. | | | | | | 22. M-17 PRIMARY AIR CHASE DETAIL SHOWS | | | ACCESS DOOR.FIRE/SMOKE DAMPERS & | | | ACCESS DOORS SHALL ALSO BE LOCATED ON | | | THE PLAN PER 2001 FBC(M)607.6. | | | | | | 23. PROVIDE OUTSIDE AIR CALCULATIONS | | | FOR | | | ALL AREAS, RESIDENCE, COMMON AREAS, | | | EQUIPMENT RMS, MECH, ELEC, PUMP RMS, | | | STORAGE RMS.SHOW COMPLIANCE WITH 2001 | | | FBC(M)402 OR TABLE 403.3. | | | | | | 24. M-16 SMOKE CONTROL SEQUENCE OF | | | OPERATION.SMOKE CONTROL SHALL COMPLY | | | WITH ONE OF THE ITEMS DESCRIBED IN | | | 412.5 | | | OF THE 2001 FBC.INDICATE WHICH | | | PROCESS | | | WILL BE USED FOR REMOVAL OF PRODUCTS OF | | | COMBUSTION. | | | | | | 25. PROVIDE MANUAL J CALCULATIONS IN | | | ACCORDANCE WITH 2001 FBC CHAPTER 13. | | | | | | 26. PROVIDE DETIAL FOR THE CONDENSATE. | | | INDICATE TERMINATION. | | | | | | PLEASE NOTE, ADDITIONAL COMMENTS NOT | | | ADDRESSED IN THIS REVIEW MAY OCCUR ON | | | RESUBMITTAL DUE TO THE REPONSE TO | | | COMMENTS AND THE INCOMPLETION OF PLANS | | | SUBMITTED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2005-07-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-07-30 |
Time |
13:36 |
Rev Time |
51.00 |
| Received By |
kstevens |
Date |
2005-07-22 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2005-07-30 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | FHA-98 DESIGN MANUAL | | | | | | A) COMMENTS FROM PREVIOUS REVIEW THAT | | | HAVE NOT BEEN ADDRESSED, OR NOT | | | ADDRESSED PROPERLY. THE COMMENT NUMBER | | | WILL REMAIN THE SAME AS THE FIRST | | | REVIEW: | | | 1) SHTS I-1, & I-2 FIRM LICENSE NUMBER | | | REQUIRED ON THE TITLE BLOCK, SIGNATURE | | | REQUIRED, AND PRINTED NAME REQUIRED. FAC | | | 61G1-16.004(2)(5)(6), 61G1-16.003 AND FS | | | 481.219. - SUBMIT PROOF OF A LEGAL | | | SIGNATURE IN THE FORM OF A DRIVERS | | | LICENSE, VOTERS REG. CARD ECT., AND | | | SUBMIT A SIGNED/SEALED/DATED NOTORIZED | | | LETTER WITH YOUR LEGAL SIGNATURE FOR OUR | | | FILES. (TITLE BLOCK REQD ON LETTER). - | | | THIS COMMENT HAS NOT BEEN ADDRESSED, NOR | | | HAS A RESPONSE BEEN NOTED. | | | 3) SHTS A-11 & A-12 SHT INDEX STATES | | | PARTIAL 3RD-7TH FLOOR PLAN 1, BUT NOTE 5 | | | STATES 3RD-5TH FLOOR PLAN. PLEASE | | | CLARIFY. SECTION 104.2.1. - THIS HAS NOT | | | BEEN ADDRESSED, NOR HAS A RESPONSE BEEN | | | NOTED. | | | 4) SHTS A-9 & A-15 SUBMIT CALCULATIONS | | | FOR PRIMARY AND SECONDARY ROOF DRAINS | | | PER SECTIONS 1106, & 1107 AND ALL | | | SUBSECTIONS. SHOW SF OF EACH AREA WITH | | | 1/2 AREA OF ALL VERTICAL WALLS INCLUDING | | | PARAPETS AND ROOF AREA FROM ABOVE THAT | | | DRAINS TO THE ROOF FROM ABOVE ADDED TO | | | THE SF IN THE CALCULATIONS. SHOW THE | | | LOCATION OF ALL PRIMARY AND SECONDARY | | | ROOF DRAINS AND THE SCUPPERS. ALSO SEE | | | SHTS A-17 & A-18. THIS APPLIES TO THE | | | ROOF DECK AREAS AS WELL. THIS HAS NOT | | | BEEN ADDRESSED, NOR HAS A RESPONSE BEEN | | | NOTED. | | | 5) SHTS A-9 & A-15 SHOW THE LOCATION AND | | | SIZE OF ALL SECONDARY ROOF DRAINS & | | | SCUPPERS. SECTION 104.2.1. - THIS HAS | | | NOT BEEN ADDRESSED, NOR HAS A RESPONSE | | | BEEN NOTED. | | | 6) SHTS A-15 & A-16 SUBMIT CALCULATIONS | | | FOR MINIMUM FACILITIES PER TABLES 1003.1 | | | AND 403.1. SHOW THE SF OF EACH COMMON | | | AREA, AND THE TOTAL COMMON AREA IN THE | | | CALCULATIONS. - THIS HAS NOT BEEN | | | ADDRESSED, NOR HAS A RESPONSE BEEN | | | NOTED. | | | 7) ARCHITECTURAL SHEETS, THE DATE | | | PREPARED AND THE PRINTED NAME OF THE | | | PERSON RESPONSIBLE FOR THE DOCUMENT ARE | | | REQUIRED PER FAC 61G1-16.004(4)(6) AND | | | FS 481.2055. - THE PRINTED NAME OF THE | | | PERSON HAS NOT BEEN ADDED TO THE TITLE | | | BLOCK. NO RESPONSE NOTED. | | | 8) SHTS A-30, A-31, & A-32 INDICATE | | | SPECIFICATION "A" OR "B" FOR EACH UNIT | | | OR BATHROOM AS REQUIRED ON PAGE 7.35 OF | | | THE FHA DESIGN MANUAL. - SHT A-30 ONLY | | | UNIT B-2 IS INDICATED. - SHT A-32 UNITS | | | E-4, E-4L, & E-6 ARE NOT INDICATED. - IF | | | SPECIFICATION "A" ALL BATHROOMS AND ALL | | | FIXTURES SHALL COMPLY. SEE PAGE 7.34. | | | 9) SHTS A-30, A-31, & A-32 SHOW THE SIZE | | | OF THE OPENINGS FOR ALL COVERED WATER | | | CLOSETS. MINIMUM 33" REQUIRED. SEE PAGES | | | 6.5 AND 6.7 OF THE FHA DESIGN MANUAL. - | | | THE 18" FROM THE WALL TO THE CENTERLINE | | | OF THE W/C IS AN ABSOLUTE MEASURMENT. | | | SEE FIGS PAGE 6.3 & 6.5. - NO RESPONSE | | | NOTED AND NOT ALL OPENINGS ARE INDICATED | | | AND NOT ALL OPENINGS MEET THE | | | REQUIREMENTS OF FHA DESIGN MANUAL. | | | 10) SHT A-33 MENS AND WOMENS RESTROOMS, | | | SHOW CLEAR FLOOR SPACE FOR EACH | | | ACCESSIBLE FIXTURE. SECTIONS 11-4.16.2, | | | 11-4.19.3, & 11-4.22.3. THE TURNING AREA | | | SHALL BE SHOWN IN THE TOILET ROOM, NOT | | | IN THE ACCESSIBLE STALL. ALSO SHOW WATER | | | CLOSET HEIGHT PER 11-4.16.3. GRAB BAR | | | HEIGHT MAX. 36", SHOWN AS 48" ON DETAIL | | | BEHIND W/C. SHOW FLUSH CONTROL 11-4.16.5 | | | SHOW URINAL HEIGHT 11-4.18.2. THE | | | CENTERLINE OF THE W/C SHALL BE 18" TO | | | THE WALL FROM THE CENTERLINE OF THE | | | FIXTURE, NOT 20" AS SHOWN. (SEE FIG. 28) | | | FOR THE LAVS SHOW KNEE CLEARANCE | | | 11-4.19.2, FOR THE SHOWER SHOW CONTROLS | | | 11-4.21.5, SHOWER UNIT 11-4.21.6, AND | | | CURB HEIGHT 11-4.21.8. - BACK AND SIDE | | | GRAB BARS SHALL BE AT THE SAME HEIGHT. | | | SEE FIG. 29. W/C HEIGHT 17" TO 19". 20" | | | DIMENSION SHOWN ON SOME W/C'S. | | | 11) NOT USED | | | 12) SHT A-33 DETAIL #1 IN BOTH THE MEN'S | | | AND WOMEN'S RESTROOMS. THE DOUBLE LAVS | | | TO BE 34" IN HEIGHT AND HAVE A CLEARANCE | | | OF 29". SEE FIG 31. SECTION 11-4.19.2. - | | | NO RESPONSE NOTED. NOT ADDRESSED. | | | 13) A DRINKING FOUNTAIN IS REQUIRED IN | | | THE COMMON AREA. TABLE 403.1. SUBMIT A | | | DETAIL COMPLYING WITH SECTIONS 11-4.15 | | | AND ALL SUBSECTIONS & 11-4.1.3(10)(A) | | | FOR THOSE WHO HAVE DIFFICULTY BENDING OR | | | STOOPING. - NO DETAIL FOUND, NOR WAS A | | | RESPONSE NOTED. | | | 14) SHT A-36 SHOW HEIGHT AND WIDTH OF | | | SCUPPER OPENINGS ON THE DETAIL. SECTIONS | | | 104.2.1 AND 1107.3. NO DETAIL FOUND, NOR | | | WAS A RESPONSE NOTED. | | | 15) A PROFESSIONAL ENGINEER SHALL SIGN | | | HIS NAME. INITIALS ARE NOT APPROVED PER | | | FBPE RULING. SUBMIT AN EXAMPLE OF THE | | | ENGINEERS LEGAL SIGNATURE BY WAY OF | | | DRIVERS LICENSE, VOTERS REG. ECT., AND A | | | SIGNED, SEALED, DATED, NOTORIZED LETTER | | | WITH TITLE BLOCK INDICATING YOUR LEGAL | | | SIGNATURE FOR OUR FILES. | | | 61G15-23.002(1)(2) AND FS 471.025. THIS | | | IS FOR ALL ENGINEERED SHEETS. - LETTER | | | WAS NOT SIGNED, SEALED, DATED, NOR DID | | | THE LETTER HAVE A TITLE BLOCK ON IT. | | | 18) SUBMIT MANUF. SPECIFICATION SHEETS | | | FOR THE STORM WATER SUMP PUMPS. PUMP | | | INFORMATION SHALL SHOW THE LISTING. | | | SECTION 303.4.(SUBMITTALS NOT FOUND). - | | | STILL NO RESPONSE TO THIS COMMENT. | | | 19) SHTS P-3 & P-4 PIPE SIZING NOT | | | CORRECT FOR EMERGENCY ROOF DRAIN PIPING, | | | (SECONDARY ROOF DRAINS). SEE TABLES | | | 1106.2 & 1106.3. STAIRWAY #2 NOT ADDED | | | TO THE SYSTEM. DOUBLE CHECK ALL PIPE | | | SIZES AND SHOW ADDITION OF ALL SF AS | | | THEY ACCUMULATE IN THE STORM BLDG. | | | DRAIN. SECTION 104.2.1. - THERE ARE | | | STILL SOME PIPE SIZES AND SF NOT SHOWN | | | ON THESE SHEETS. | | | 27) SHT P-5 CHECK ALL PIPE SIZING ON THE | | | STORM SYSTEM AND SHOW ALL PIPE SIZES. | | | SECTION 104.2.1. & TABLES 1106.2 & | | | 1106.3. - THERE ARE STILL PIPE SIZES | | | MISSING AND SF AS IT ACCUMULATES. NO | | | RESPONSE NOTED. | | | 34) SHT P-11AUXILLARY HORIZONTAL DRAIN | | | PIPE SIZE NOT CORRECT. TABLE 1106.3. - | | | NO RESPONSE NOTED. - SEE RWL S/8. | | | 35) THE TRASH CHUTE BEQUIRES AN "N-36" | | | VACUUM BREAKER FOR BACKFLOW PROTECTION. | | | SECTION 608.13.6. NO RESPONSE. SHEET | | | VOIDED BUT NO NEW SHEET SUBMITTED. | | | 36) SHT P-12 AUXILLARY HORIZONTAL DRAIN | | | PIPE TO BE SIZED PER TABLE 1106.3. NO | | | RESPONSE. SHEET VOIDED BUT NO NEW SHEET | | | SUBMITTED. | | | 37) SHTS P-13, & P-14 AUXILLARY ROOF | | | DRAIN NEAR POOL SHALL NOT BE A TRIPPING | | | HAZARD. PLEASE SUBMIT A DETAIL FOR S/27, | | | S/28, S/29, & S/30 SECONDARY DRAINS. | | | SECTION 104.2.1. NO RESPONSE NOTED. SHT | | | VOIDED, BUT NO NEW SHEET SUBMITTED. | | | 38) SHT P-22 NO WATER SUPPLY SHOWN TO | | | THE TRASH ROOM FOR THE TRASH CHUTE. | | | PLEASE SHOW ON PLANS. SECTION 104.2.1. | | | NO RESPONSE NOTED. SHEET VOIDED, BUT NO | | | NEW SHEET SUBMITTED. TRASH CHUTE NOTES | | | ON SHT 42 INDICATES THAT A WASH DOWN | | | HEAD IS LOCATED AT THE TOP OF THE CHUTE. | | | 39) SHTS P-24, P-25, P-26, P-27, & P-28 | | | DO NOT MEET CODE REQUIREMENTS. IN MANY | | | CASES THESE ARE THE CODE ISSUES NOT | | | ADDRESSED. - THESE COMMENTS NOW APPLY TO | | | SHTS 23, 29, 30, & 31 AS NEW RISERS HAVE | | | BEEN SUBMITTED, AND SHEET INFORMATION | | | HAS CHANGED. | | | A. OFFSET VENTS ARE REQUIRED WHEN | | | HORIZONTAL OFFSET ARE USED. SECTION 915. | | | RESPONSE NOT APPROVED. OFFSET VENTS | | | SHALL BE SHOWN ON THE RISER DIAGRAMS. | | | SEE SECTION 104.2.1. - STILL SOME NOT | | | SHOWN AS REQUIRED | | | B. NO HORIZONTAL DRY VENTS. SECTION | | | 905.3. - OK | | | C. STACK DRAIN SHALL CONNECT DOWNSTREAM | | | OF BATHROOM GROUP FIXTURES. SECTION | | | 909.1 - OK | | | D. KITCHEN SINK SHALL NOT DRAIN THROUGH | | | THE WET VENT. SECTION 909.1 - OK | | | E. MAIN VENT REQUIRED AT TOP OF STACKS. | | | SECTION 903.1. SOME STILL NOT PIPED | | | CORRECTLY. | | | F. CLEANOUTS REQUIRED AT THE BASE OF | | | EACH STACK. SECTION 708.3.4. - OK | | | G. NO HORIZONTAL BRANCH CONNECTIONS TO | | | A HORIZONTAL STACK OFFSET. SECTIONS | | | 711.2 & 711.3. - OK | | | H. VENTING REQUIRED 901.2.1. | | | I. (NEW COMMENT) EVERY VENT STACK SHALL | | | CONNECT TO THE BASE OF THE DRAINAGE | | | STACK. THE VENT STACK SHALL CONNECT AT | | | OR BELOW THE LOWEST HORIZONTAL BRANCH. | | | SECTION 903.4 - SOME VENT STACKS ARE NOT | | | CONNECTED TO THE STACK, BUT CONNECT TO | | | THE BRANCH LINE. | | | J. STACK INSTALLATION 910.2 | | | THE RISERS ARE NOT CLEAR AS TO THEIR | | | INTENT. CHECK ALL RISERS FOR CODE | | | REQUIREMENTS. - OK | | | 43) SHT P-31 AIR CHAMBERS ARE NOT | | | APPROVED. DELETE FROM ALL RISERS. WATER | | | HAMMER ARRESTORS REQUIRED BY SECTION | | | 604.9 SHALL BE LOCATED AT ALL QUICK | | | CLOSING VALVES, (W/M, ICE MAKER, & D/W), | | | AND SHALL BE LOCATED NEAR THE FIXTURE. | | | PDI-WH 201 AND MANUF. INSTALL. INSTRUCT. | | | - ONLY ONE SET OF AIR CHAMBERS STILL | | | REMAIN TO BE DELETED. SHT P-35 UNIT | | | L/W-D-2 FIXTURE P-2 2ND FLOOR. | | | 44) SHTS P-33 & P-34 AUXILLARY ROOF | | | DRAINS ON SOME SYSTEMS ARE UNDERSIZED. | | | PLEASE SIZE PIPE PER TABLE 1106.3. ROOF | | | DRAINS CHANGED TO SHTS 39, 40, 41, & 42, | | | AND STILL HAVE SOME AUXILLARY ROOF DRAIN | | | PIPING SIZED INCORRECTLY. SOME DRAINS | | | ARE STILL SIZED INCORRECTLY. ALSO SHOW | | | SF AS IT ACCUMULATES. | | | 45) SHT P-35 STORM DRAIN RISER 111, SHOW | | | ALL PIPE SIZES AND SQUARE FOOTAGE AS IT | | | ACCUMULATES IN THE SYSTEM. RECHECK ALL | | | PIPE SIZES PER TABLES 1106.2 & 1106.3 AS | | | SOME PIPE SIZES ARE INCORRECT. THERE ARE | | | STILL SOME PIPE SIZES THAT ARE | | | INCORRECT. RISER III CHANGED TO RISER II | | | AND MOVED TO SHT 41.1. - SIZES ON SOME | | | PIPES ARE INCORRECT STILL, AND SQUARE | | | FOOTAGE AS IT ACCUMULATES IS STILL NOT | | | SHOWN AT EACH BRANCH LINE OR RISER. | | | 49) SUBMIT A CONDENSATE DRAIN ISOMETRIC | | | WITH ALL PIPE SIZES, LOCATION OF RISER | | | CONNECTIONS, RISERS, TERMINATION POINT | | | OF THE RISERS (VENTS), AND INDICATE | | | WHERE THE CONDENSATE DRAINS TO THE | | | OUTSIDE OF THE BUILDING. SECTION | | | 104.2.1. LOCATION OF TERMINATION POINT | | | FOR THE CONDENSATE HAS NOT BEEN GIVEN. | | | 2ND REVIEW | | | **************NEW COMMENTS************** | | | 1B) NEW FLOOR LAYOUTS, NEW REVIEW | | | 2B) SHTS A27 THRU A32 ALL TYPICAL UNITS | | | SHOW CLEAR FLOOR SPACE FOR W/C'S PER | | | PAGE 7.43 FHA DESIGN MANUAL. SEE MINIMUM | | | CLEAR FLOOR SPACE SIZE REQUIREMENTS. - | | | SHOWER CLEAR FLOOR SPACE SHALL BE | | | PARALLEL AND FLUSH WITH THE CONTROL | | | WALL. SEE PAGE 7.56.- THIS COMMENT HAS | | | NOT BEEN ADDRESSED PROPERLY AS PER FHA | | | DESIGN MANUAL. - NO RESPONSE NOTED. | | | 3B) SHTS A27 THRU A32 ALL TYPICAL UNITS | | | WATER CLOSETS SHALL BE 18" OFF WALL TO | | | CENERLINE OF FIXTURE. SEE PAGES 6.5, | | | 7.43, 7.44 & 7.45. THIS IS WHEN THE W/C | | | IN NEXT TO A WALL. - THIS HAS NOT BEEN | | | ADDRESSED, NOR HAS A RESPONSE BEEN | | | NOTED. | | | 4B) SHTS A27 THRU A32 ALL TYPICAL UNITS | | | SHALL SHOW THE DIMENSIONS FOR THE W/C | | | OPENINGS. MINIMUM 33" REQUIRED. SEE | | | PAGES 7.43 THRU 7.45. THIS HAS NOT BEEN | | | ADDRESSED, NOR HAS A RESPONSE BEEN | | | NOTED. | | | 5B) SHT A1 DRAWING INDEX DOES NOT | | | REFLECT DRAWING SHEETS. SECTION 104.2.1. | | | - THIS HAS NOT BEEN ADDRESSED, NOR HAS A | | | RESPONSE BEEN NOTED. | | | 8B) SHT P-3 STORM AND AUXILLARY | | | PIPING SIZE IS NOT CORRECT IN MANY | | | AREAS. CHECK PIPE SIZE PER TABLES 1106.2 | | | AND 1106.3. SOME PIPE SIZE STILL NOT | | | CORRECT. | | | 7B) SHT P-4 SOME PIPE SIZES ARE NOT | | | SHOWN. TABLES 1106.2 & 1106.3 AND | | | SECTION 104.2.1. | | | 11B) SHT P-6 SHOW PIPING FOR PD(3061SF). | | | TABLE 1106.3 AND SECTION 104.2.1. - 4" | | | SHOWN BUT 6" REQUIRED. - FLOOR PLAN DOES | | | NOT REFLECT THE RISER DIAGRAM (100). | | | SECTION 104.2.1. - THIS STILL DOES NOT | | | REFLECT THE FLOOR PLAN. | | | 12B) SHT P-7 6" REQUIRED ON AUXILLARY | | | DRAIN LINES AT RISERS S/28, & S/29. 5" | | | REQUIRED ON AUXILLARY DRAIN LINE BETWEEN | | | COL. - PIPE SIZES NOT SHOWN FOR ROOF | | | DRAINS, PRIMARY AND SECONDARY FOR COMMON | | | PATIO AND PRIVATE LANAI AREAS. SECTION | | | 104.2.1 AND TABLE 1106.3. - UNABLE TO | | | FIND S/28 & 2/29. PLEASE SHOW AN INDEX | | | OF ALL STORM RISER DIAGRAMS USED. - PIPE | | | SIZES NOT SHOWN ON AUXILLARY ROOF DRAINS | | | DOWNSTREAM OF S/44 THEN SHOWN AS 4" | | | DOWN. MINIMUM 5" REQUIRED. NOT ALL PIPE | | | SIZES ARE SHOWN. | | | 13B) SHT P-8 6" REQUIRED ON AUXILLARY | | | DRAINS S/26 & S/29. 8" REQUIRED ON | | | AUXILLARY DRAINS S/14, & S/18. SHOW ALL | | | PIPE SIZES FOR ROOM PRIMARY & SECONDARY | | | DRAINS AT COMMON PATIO AND PRIVATE LANAI | | | AREAS. TABLES 1106.2 & 1106.3. - NOW | | | UNABLE TO LOCATE RISER S/29 PLEASE | | | CLARIFY. - NOT ALL PIPES SIZES SHOWN. | | | 14B) SHT P-10 UNIT C-3L MAX. 4 FU ON 2" | | | WET VENT. TABLE 909.3 - UNITS C-4L, | | | B-4L, & C-6L STILL SHOW NO PIPE SIZE FOR | | | THE SECTION OF PIPE DOWNSTREAM OF THE | | | LAST FIXTURE, (P-2 OR P-2A), 5FU. | | | MINIMUM 3" REQUIRED. | | | 17B) SHT P-23 RISER 3,4,5,6 DOES NOT | | | REFLECT THE FLOOR PLAN. SHT P-3 SHOWS | | | RISER 6 CONNECTING TO RISER 345 ON THE | | | FIRST FLOOR NOT AT THE MEZZ. LEVEL AS | | | SHOWN ON THE RISER. SECTION 104.2.1. - | | | SHT P-5 SHOWS ONLY RISER #8 WITH RISERS | | | 3,4,5,6 CONNECTING TO THIS RISER. | | | CORRELATE RISERS AND FLOOR PLAN. - | | | SHOULD BE RISER 3,4,5,6,8 WITH 3,4,5,6 | | | SPLITTING OFF AT MEZZ. LEVEL AND RISER 8 | | | OFFSETTING AT THE 2ND FLOOR TO REFLECT | | | THE FLOOR PLAN. | | | 18B) SHT P-23 RISER #7 DOES NOT REFLECT | | | FLOOR PLAN ON SHT P-5 AT LAV. - THIS HAS | | | NOT BEEN ADDRESSED, NOR WAS THERE A | | | COMMENT RESPONSE. | | | 19B) SHT P-23 RISER DOES NOT REFLECT | | | FLOOR PLAN AT RISER 10 ON THE 2ND FLOOR. | | | CORRELATE RISER AND FLOOR PLAN. SECTION | | | 104.2.1. - NOT ADDRESSED, NO COMMENT | | | RESPONSE. | | | 23B) SHT P-35 DELETE AIR CHAMBERS | | | SECTION 104.2.1. SEE RISER 11-11R AT | | | FIXTURE P2. AIR CHAMBER NOT DELETED. | | | 25B) SHTS P-39, P-40, P-41, & P-41.1, | | | CHECK ALL AUXILLARY DRAINS FOR CORRECT | | | SIZE. TABLE 1106.3 @ 4.5"/HR. - SOME | | | SIZES NOT SHOWN. 42, 43, 44, TO BE 5" | | | DOWN. | | | **************************************** | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. - | | | NO RESPONSE TO THIS REQUIRES LAST | | | SUBMITTAL. - NO RESPONSE TO THIS REQUEST | | | SECOND REVIEW ALSO. THIS ADDS ADDITIONAL | | | TIME TO THE PLAN REVIEW AS IT CAUSES THE | | | PLAN TO BE REVIEWED AS A NEW REVIEW EACH | | | TIME. | | | **************************************** | | | ********COMMENTS FOR THIRD REVIEW******* | | | **************************************** | | | 1C. SHT P-6 AUXILLARY DRAINS, MINIMUM 6" | | | REQUIRED FOR PD 3061SF BY HDCP PARKING | | | SPACE 64, 4" SHOWN. - 8" HORIZONTAL | | | REQUIRED PD'S 5866 SF TOTAL COL. 11/F. | | | 2C. SHT P-7 AUXILLARY DRAINS, MINIMUM 5" | | | REQUIRED ON HORIZONTAL FOR S/9, S/32, | | | S/33, @ 842 SF, & S/42, S/43, S/44 @ | | | 1429 SF. | | | 3C. SHT P-8 AUXILLARY DRAINS, MINIMUM 5" | | | REQUIRED ON HORIZONTAL FOR S/54, S/55, | | | S/56 @ 1142 SF AND DOWNSTREAM, AND FOR | | | S/16, S/46, S/47 @ 842 SF. | | | 4C. SHT P-39 RISERS S/2, S/9-S/32-S/33, | | | S/42-S/43-S/44 MINIMUM 5" REQUIRED FOR | | | AUXILLARY DRAINS OVER 800 SF. | | | 5C. SHT P-40 S/28.2 SF DOES NOT REFLECT | | | SF ON SHT P-11. CORRELATE RISER AND ROOF | | | LAYOUT. - AUXILLARY S/18 MINIMUM 8" | | | REQUIRED. - AUXILLARY S/26 MINIMUM 6" | | | REQUIRED. - AUXILLARY S/54-S/55-S/56 | | | SHOW 5" ON HORIZONTAL DOWNSTREAM OF | | | S/55. | | | 6C. SHT P12 2/14 & S/18 8" REQUIRED ON | | | AUXILLARY DRAIN. - S/26 6" REQUIRED ON | | | AUXILLARY DRAIN. TABLE 1106.3 | | | 7C. SUBMIT A DETAIL FOR ROOF SCUPPERS. | | | SHOW HEIGHT AND WIDTH AND INDICATE | | | MEASUREMENT FROM ROOF TO FLOW LINE OF | | | SCUPPER AS REQUIRED BY SECTION 15-3.4.2. | | | 8C. SHT P-23 SANT. RISER DIAGRAM 1 & 2 | | | SHOWS A 4" VENT LINE THAT WAS OFFSET ON | | | THE 2ND FLOOR CONTINUING ON THE 3RD THRU | | | 7TH FLOOR AND OFFSETTING AGAIN. PLEASE | | | CLARIFY. - SANT. RISER 2 STACK VENT TO | | | EXTEND AND CONNECT TO VENT LINE. SECTION | | | 903.1. - SANT. RISERS 6, 7, & 8 VENT | | | STACK SHALL CONNECT TO THE DRAINAGE | | | STACK NOT THE FIXTURE BRANCH. SECTION | | | 903.4. - SANT. RISER 7 UPPER PORTION OF | | | OFFSET VENT REQUIRED. | | | 9C. SHT P-24 SANT RISERS 15, 18, 17, 19, | | | VENT TO CONNECT TO DRAINAGE STACK NOT | | | FIXTURE BRANCH. 903.4 | | | 10C. SHT P-24 SANT. RISERS 17 & 19, | | | (TOP), OFFSET VENTS REQUIRED. SECTION | | | SECTION 915. | | | 11C. SHT P-24 SANT. RISERS 21 & 25 STACK | | | VENT TO EXTEND AND TIE INTO VENT STACK. | | | SECTION 903.1. | | | 12C. SANT. RISER 23 VENT STACK NOT | | | REQUIRED. SANT. RISER 25 CHANGE OFFSET | | | VENT TO CONNECT TO DRAINAGE STACK PER | | | SECTION 903.4. | | | 10C. SHT P-25 SANT. RISER 28 VENT STACK | | | NOT REQUIRED. - SANT. RISER 27 STACK | | | VENT TO EXTEND AND TIE INTO VENT STACK. | | | SECTION 903.1. | | | 11C. SHT P-25 SANT. RISERS 30, 31, 34. | | | 37 VENT STACK SHALL CONNECT TO THE | | | DRAINAGE STACK, NOT THE BRANCH LINE. | | | SECTION 903.4. - SANT. RISER 37 SHOWS | | | THE PIPING DIRECTION AWAY FROM THE | | | STACK. PLEASE CLARIFY. SECTION 104.2.1. | | | 12C. SANT. RISER 35 MAXIMUM 4 FU ON 2" | | | WET VENT. NO PIPE SIZE SHOWN. ALL | | | FLOORS. TABLE 909.3 | | | 13C. SHT P-26 SANT. RISER 38/39 IDENTIFY | | | FIXTURE ON MEZZ. LEVEL, AND A VENT IS | | | REQUIRED FOR SAME FIXTURE. 901.2.1. | | | 14C. SHT P-26 SANT. RISERS 38/39, 40, | | | 41, 43, 44, 46, 47, 48/49 CONNECT VENT | | | STACK TO DRAINAGE STACK AT BASE OF STACK | | | PER SECTION 903.4. - SANT. RISER VENT TO | | | EXTEND AND TIE INTO VENT STACK. SECTION | | | 903.1. - SANT. RISER 46 OFFSET VENT NOT | | | REQUIRED. - SANT. 48/49 EXTEND STACK | | | VENT AND CONNECT TO VENT STACK. SECTION | | | 903.1. | | | 15C. SHT P-27 SANT. RISER 81/105 OFFSET | | | VENT NOT REQUIRED. - MAX 4 FU ON 2" WET | | | VENT. TABLE 909.3 - ALL FLOORS. - | | | CONNECT VENT STACK TO DRAINAGE STACK PER | | | SECTION 903.4. | | | 16C. SHT P-27 SANT. RISER 79 CONNECT | | | VENT STACK TO DRAINAGE STACK PER SECTION | | | 903.4 - STACK VENT TO CONNECT TO VENT | | | STACK AT TOP OF RISER. SECTION 903.1. | | | 17C. SANT. RISERS 82.106 & 85 MAXIMUM 4 | | | FU ON 2" WET VENT. TABLE 903.3. ALL | | | FLOORS. | | | 18C. SANT RISER 84 CONNECT VENT STACK TO | | | DRAINAGE STACK NOT BRANCH LINE PER | | | SECTION 903.4. | | | 19C. SHT P-28 ALL SANT. RISERS CONNECT | | | THE VENT STACKS TO THE DRAINAGE STACKS | | | PER SECTION 903.4. | | | 20C. SHT P-28 SANT. RISER 51/52 SHOW 3 | | | STACKS, BUT ONLY 2 STACK NUMBERS. PLEASE | | | CLARIFY. SECTION 104.2.1. - OFFSET VENT | | | SHALL CONNECT TO SOIL STACK (52) NOT | | | STACK 51. | | | 21C. SHT P-28 SANT. RISER 53 OFFSET VENT | | | REQUIRED FOR OFFSET BETWEEN MEZZ. & 2ND | | | FLOOR. SECTION 915. - MAXIMUM 4 FU ON 2" | | | WET VENT. TABLE 903.3. | | | 22C. SHT P-28 SANT. RISER 54-55-55.1 | | | OFFSET VENT REQUIRED BETWEEN MEZZ. LEVEL | | | AND 2ND FLOOR. | | | 23C. SHT P-28 OFFSET VENT & VENT LINE | | | ARE NOT REQUIRED. | | | 24C. SHT P-28 INDICATE STACK NUMBER FOR | | | STACK BETWEEN RISERS 57 & 58. SECTION | | | 104.2.1. | | | 25C. SANT. RISER 57 EXTEND STACK VENT | | | AND TIE INTO VENT STACK. SECTION 903.1. | | | 26C. SHT P-28 SANT. RISER 59 MAXIMUM 4 | | | FU ON 2" WET VENT. TABLE 903.3. ALL | | | FLOORS. | | | 27C. SHT P-29 SANT. RISERS 62, 64, 66, | | | 71, 73, 74, 99, & 102 CONNECT THE VENT | | | STACK TO THE DRAINAGE STACK PER SECTION | | | 903.4. | | | 28C. SHT P-29 SANT. RISER 73 EXTEND | | | STACK VENT AND CONNECT TO VENT STACK. | | | SECTION 903.4. | | | 29C. SHT P-29 SANT. 100 OFFSET VENT AND | | | VENT LINE NOT REQUIRED. SECTION 104.2.1. | | | 30C. SHT P-31 SANT. RISERS 92, 95, 97/98 | | | CONNECT VENT STACK TO DRAINAGE STACK PER | | | SECTION 903.4. | | | 31C. SHT P-31 SANT. RISER 93 INDICATE | | | VENT SIZE. TABLE 916.1. | | | 32C. SHT P-31 SANT. RISER 97 EXTEND | | | STACK VENT AND CONNECT TO VENT STACK. | | | SECTION 903.1. | | | 33C. SHT P-38 A/C CLOSET IS SHOWN AS A | | | PLENUM. PVC OR CPVC IS NOT ALLOWED IN | | | THE PLENUM. INDICATE MATERIAL TYPE FOR | | | CONDENSATE LINES IN THE PLENUM. SECTIONS | | | 303.2. AND 602.2.1 OF THE MECHANICAL | | | CODE. | | | 34C. SHT P-42 WATER HEATER DIAGRAM SHOWS | | | P/T TO HEATER PAN, BUT STATES 3/4" DRAIN | | | TO OUTSIDE. PLEASE CLARIFY. SECTION | | | 104.2.1. | | | 35C. SHT P-1 STORM SHOWS 12" HORIZONTAL, | | | THEN 10" UP TO FIRST FLOOR AT COL. LINE | | | 5/G. PIPING SHALL NOT BE REDUCED IN THE | | | DIRECTION OF FLOW PER SECTION 704.2. | | | 36C. SUBMIT AN ISOMETRIC STORM DRAIN | | | RISER DIAGRAM FOR THE PD DRAIN SYSTEMS | | | SHOWING ALL PIPE SIZES AND SF AS IT | | | ACCUMULATES IN THE SYSTEM TO REFLECT THE | | | FLAT PD DRAINAGE SYSTEM. SECTION | | | 104.3.1.1. | | | 37C. SHT P-11 RISER S/8, 8" MINIMUM | | | REQUIRED ON AUXILLARY. TABLE 1106.3. | | | 38C. SHT P-12 RISERS S/14, & S/18, 8" | | | MINIMUM REQUIRED ON AUXILLARY. TABLE | | | 1106.3. | | | 39C. SHT P-12 RISER S/26, 6" MINIMUM | | | REQUIRED ON AUXILLARY. TABLE 1106.3. | | | 40C. SHT P-12 RISERS S17, & S/17.1 DOWN | | | AND DOWN AUXILLARY MISLABELED. SECTION | | | 104.2.1. | | | 41C. SHTS P13 & P14 SHOWS "THRU SCUPPER" | | | PLEASE CLARIFY. POOL DECK REQUIRES | | | PRIMARY AND SECONDARY ROOF DRAINS PER | | | SECTIONS 1106 & 1107. SHOW THE LOCATION | | | OF ALL REQUIRED DRAINS. | | | 42C. SHT P-32 RISER 3/4/5/6/8 DOES NOT | | | REFLECT THE FLOOR PLAN. ALL VENT STACKS | | | SHALL CONNECT TO THE DRAINAGE STACK PER | | | SECTION 903.4. | | | 43C. SHTS P-33 & P-34 ALL VENT STACKS | | | SHALL CONNECT TO THE DRAINAGE STACK. | | | SECTION 903.4. | | | 44C. SHT P-35 UNIT L/W-D-2 DELETE | | | AIR CHAMBERS FROM FIXTURE P-2, 2ND | | | FLOOR. SECTION 604.9. | | | 45C. SHTS P-39 & P-40 SEE COMMENT NUMBER | | | 5 FROM PREVIOUS REVIEW CONCERNING | | | DRAWING INDEX. SECTION 104.2.1. | | | 46C. SHTS P-41 & P41.1 SHOW ALL PIPE | | | SIZES, AND RECHECK ADDITION ON SF. - | | | DOWNSTREAM OF 8" @ 1/8"/FT 8615 SF SHOWS | | | 10" @ 1/8"/FT 10713 SF AND NO BRANCH | | | LINES INBETWEEN. PLEASE CLARIFY. - | | | DOWNSTREAM OF S/49-S/50 AUXILLARY SHOWS | | | A LINE CONNECTING INTO THE STORM LINE. | | | DELETE FROM SHEETS. | | | 47C. SHT P-42 SUMP PUMP DETAIL, PUMP AND | | | WASTE LINE NOT APPROVED. OIL SHALL BE | | | RECLAIMED AND RECYCLED. DELETE FROM | | | DETAIL. | | | 48C. SHT P-42 CONDENSATE DRAIN TRAP | | | DETAIL. MATERIAL TO BE USED FOR THE TRAP | | | AND CONDENSATE LINE IS STATED AS PVC IN | | | THE GENERAL PLUMBING NOTES #4(C). THIS | | | IS NOT APPROVED IN THE PLENUM. INDICATE | | | MATERIAL TO BE USED IN THE PLENUM. | | | SECTION 606.2.1 (MECH). | | | 49C. SHT P-42 TRASH CHUTE SPECIFICATION | | | #6 INDICATES A FLUSHING HEAD. AN N36 | | | VACUUM BREAKER IS REQUIRED AT THE | | | HIGHEST POINT OF THE WATER SUPPLY. SHOW | | | WATER LINE TO TRASH CHUTE ON THE WATER | | | RISER DIAGRAM. SHOW PIPE SIZE AND VACUUM | | | BREAKER. SECTIONS 104.3.1. & 608.13.8. | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. - | | | THIS HAS BEEN REQUESTED EACH REVIEW AND | | | NO RESPONSE TO THIS REQUEST HAS BEEN | | | NOTED. NO COMMENT RESPONSE AND NOT | | | RETURNING THE PREVIOUS PLANS ADDS MANY | | | HOURS TO THE REVIEW PROCESS AND SLOWS | | | THE PERMIT PROCESS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-05-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-05-19 |
Time |
17:31 |
Rev Time |
43.00 |
| Received By |
kstevens |
Date |
2005-05-14 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2005-05-19 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | FHA-98 DESIGN MANUAL | | | | | | A) COMMENTS FROM PREVIOUS REVIEW THAT | | | HAVE NOT BEEN ADDRESSED, OR NOT | | | ADDRESSED PROPERLY. THE COMMENT NUMBER | | | WILL REMAIN THE SAME AS THE FIRST | | | REVIEW: | | | 1) SHTS I-1, & I-2 FIRM LICENSE NUMBER | | | REQUIRED ON THE TITLE BLOCK, SIGNATURE | | | REQUIRED, AND PRINTED NAME REQUIRED. FAC | | | 61G1-16.004(2)(5)(6), 61G1-16.003 AND FS | | | 481.219. - SUBMIT PROOF OF A LEGAL | | | SIGNATURE IN THE FORM OF A DRIVERS | | | LICENSE, VOTERS REG. CARD ECT., AND | | | SUBMIT A SIGNED/SEALED/DATED NOTORIZED | | | LETTER WITH YOUR LEGAL SIGNATURE FOR OUR | | | FILES. (TITLE BLOCK REQD ON LETTER). | | | 2) SHT I-1, AN RPZ BACKFLOW, INSTALLED | | | BY A LICENSED PLUMBING CONTRACTOR, IS | | | REQUIRED FOR THE IRRIGATION SYSTEM. SHOW | | | THE LOCATION ON THE IRRIGATION PLANS. | | | SECTIONS 608.13.2 & 104.2.1. | | | 3) SHTS A-11 & A-12 SHT INDEX STATES | | | PARTIAL 3RD-7TH FLOOR PLAN 1, BUT NOTE 5 | | | STATES 3RD-5TH FLOOR PLAN. PLEASE | | | CLARIFY. SECTION 104.2.1. | | | 4) SHTS A-9 & A-15 SUBMIT CALCULATIONS | | | FOR PRIMARY AND SECONDARY ROOF DRAINS | | | PER SECTIONS 1106, & 1107 AND ALL | | | SUBSECTIONS. SHOW SF OF EACH AREA WITH | | | 1/2 AREA OF ALL VERTICAL WALLS INCLUDING | | | PARAPETS AND ROOF AREA FROM ABOVE THAT | | | DRAINS TO THE ROOF FROM ABOVE ADDED TO | | | THE SF IN THE CALCULATIONS. SHOW THE | | | LOCATION OF ALL PRIMARY AND SECONDARY | | | ROOF DRAINS AND THE SCUPPERS. ALSO SEE | | | SHTS A-17 & A-18. THIS APPLIES TO THE | | | ROOF DECK AREAS AS WELL. | | | 5) SHTS A-9 & A-15 SHOW THE LOCATION AND | | | SIZE OF ALL SECONDARY ROOF DRAINS & | | | SCUPPERS. SECTION 104.2.1. | | | 6) SHTS A-15 & A-16 SUBMIT CALCULATIONS | | | FOR MINIMUM FACILITIES PER TABLES 1003.1 | | | AND 403.1. SHOW THE SF OF EACH COMMON | | | AREA, AND THE TOTAL COMMON AREA IN THE | | | CALCULATIONS. | | | 7) ARCHITECTURAL SHEETS, THE DATE | | | PREPARED AND THE PRINTED NAME OF THE | | | PERSON RESPONSIBLE FOR THE DOCUMENT ARE | | | REQUIRED PER FAC 61G1-16.004(4)(6) AND | | | FS 481.2055. | | | 8) SHTS A-30, A-31, & A-32 INDICATE | | | SPECIFICATION "A" OR "B" FOR EACH UNIT | | | OR BATHROOM AS REQUIRED ON PAGE 7.35 OF | | | THE FHA DESIGN MANUAL. | | | 9) SHTS A-30, A-31, & A-32 SHOW THE SIZE | | | OF THE OPENINGS FOR ALL COVERED WATER | | | CLOSETS. MINIMUM 33" REQUIRED. SEE PAGES | | | 6.5 AND 6.7 OF THE FHA DESIGN MANUAL. - | | | THE 18" FROM THE WALL TO THE CENTERLINE | | | OF THE W/C IS AN ABSOLUTE MEASURMENT. | | | SEE FIGS PAGE 6.3 & 6.5. | | | 10) SHT A-33 MENS AND WOMENS RESTROOMS, | | | SHOW CLEAR FLOOR SPACE FOR EACH | | | ACCESSIBLE FIXTURE. SECTIONS 11-4.16.2, | | | 11-4.19.3, & 11-4.22.3. THE TURNING AREA | | | SHALL BE SHOWN IN THE TOILET ROOM, NOT | | | IN THE ACCESSIBLE STALL. ALSO SHOW WATER | | | CLOSET HEIGHT PER 11-4.16.3. GRAB BAR | | | HEIGHT MAX. 36", SHOWN AS 48" ON DETAIL | | | BEHIND W/C. SHOW FLUSH CONTROL 11-4.16.5 | | | SHOW URINAL HEIGHT 11-4.18.2. THE | | | CENTERLINE OF THE W/C SHALL BE 18" TO | | | THE WALL FROM THE CENTERLINE OF THE | | | FIXTURE, NOT 20" AS SHOWN. (SEE FIG. 28) | | | FOR THE LAVS SHOW KNEE CLEARANCE | | | 11-4.19.2, FOR THE SHOWER SHOW CONTROLS | | | 11-4.21.5, SHOWER UNIT 11-4.21.6, AND | | | CURB HEIGHT 11-4.21.8. | | | 11) NOT USED | | | 12) SHT A-33 DETAIL #1 IN BOTH THE MEN'S | | | AND WOMEN'S RESTROOMS. THE DOUBLE LAVS | | | TO BE 34" IN HEIGHT AND HAVE A CLEARANCE | | | OF 29". SEE FIG 31. SECTION 11-4.19.2. | | | 13) A DRINKING FOUNTAIN IS REQUIRED IN | | | THE COMMON AREA. TABLE 403.1. SUBMIT A | | | DETAIL COMPLYING WITH SECTIONS 11-4.15 | | | AND ALL SUBSECTIONS & 11-4.1.3(10)(A) | | | FOR THOSE WHO HAVE DIFFICULTY BENDING OR | | | STOOPING. | | | 14) SHT A-36 SHOW HEIGHT AND WIDTH OF | | | SCUPPER OPENINGS ON THE DETAIL. SECTION | | | 104.2.1. | | | 15) A PROFESSIONAL ENGINEER SHALL SIGN | | | HIS NAME. INITIALS ARE NOT APPROVED PER | | | FBPE RULING. SUBMIT AN EXAMPLE OF THE | | | ENGINEERS LEGAL SIGNATURE BY WAY OF | | | DRIVERS LICENSE, VOTERS REG. ECT., AND A | | | SIGNED, SEALED, DATED, NOTORIZED LETTER | | | WITH TITLE BLOCK INDICATING YOUR LEGAL | | | SIGNATURE FOR OUR FILES. | | | 61G15-23.002(1)(2) AND FS 471.025. THIS | | | IS FOR ALL ENGINEERED SHEETS. | | | 16) ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME, LICENSE NUMBER & CERTIFICATE | | | OF AUTHORIZATION NUMBER OF THE | | | ENGINEERING BUSINESS ON EACH SHEET. FAC | | | 61G15-23.002(2). (WHITE OUT USED ON THE | | | PLANS IS NOT APPROVED PER SECTION | | | 104.2.1.3. | | | 17) SHTS P-1 & P-2 PD'S SIZING AND | | | PIPING SIZING ARE NOT CORRECT FOR ALL | | | PD'S. RECHECK SIZING PER TABLES 1106.2 & | | | 1106.3. SHOW ALL SF AND PIPE SIZES. | | | (THIS HAS NOT BEEN ADDRESSED, AND NEW | | | SHEETS P-1 & P-2 WERE NOT SUBMITTED). | | | 18) SUBMIT MANUF. SPECIFICATION SHEETS | | | FOR ELEVATOR SUMP PUMPS AND THE STORM | | | WATER SUMP PUMPS. PUMP INFORMATION SHALL | | | SHOW THE LISTING. SECTION 303.4. | | | (SUBMITTALS NOT FOUND). | | | 19) SHTS P-3 & P-4 PIPE SIZING NOT | | | CORRECT FOR EMERGENCY ROOF DRAIN PIPING, | | | (SECONDARY ROOF DRAINS). SEE TABLES | | | 1106.2 & 1106.3. NO SF SHOWN FOR PD'S AT | | | COL. LINE 5/G-F1 AND COL. LINE 6/F-E2. | | | PD BETWEEN COLS. 8.1 & 8.3 NORTH OF | | | STAIRWAY #2 NOT ADDED TO THE SYSTEM. | | | DOUBLE CHECK ALL PIPE SIZES AND SHOW | | | ADDITION OF ALL SF AS THEY ACCUMULATE IN | | | THE STORM BLDG. DRAIN. SECTION 104.2.1. | | | *** NEW COMMENT ** (ON PD LINE 8"PD | | | (88185SF) NOTHING IS SHOWN ADDED TO | | | 10713SF) CLARIFY. - ALL PD LINES REQUIRE | | | A CLEANOUT AS LINE EXITS BLDG. | | | 27) SHT P-5 CHECK ALL PIPE SIZING ON THE | | | STORM SYSTEM AND SHOW ALL PIPE SIZES. | | | SECTION 104.2.1. & TABLES 1106.2 & | | | 1106.3. | | | 34) SHT P-11AUXILLARY HORIZONTAL DRAIN | | | PIPE SIZE NOT CORRECT. TABLE 1106.3. - | | | NO RESPONSE NOTED. SHEET VOIDED BUT NO | | | NEW SHEET SUBMITTED. | | | 35) THE TRASH CHUTE BEQUIRES AN "N-36" | | | VACUUM BREAKER FOR BACKFLOW PROTECTION. | | | SECTION 608.13.6. NO RESPONSE. SHEET | | | VOIDED BUT NO NEW SHEET SUBMITTED. | | | 36) SHT P-12 AUXILLARY HORIZONTAL DRAIN | | | PIPE TO BE SIZED PER TABLE 1106.3. NO | | | RESPONSE. SHEET VOIDED BUT NO NEW SHEET | | | SUBMITTED. | | | 37) SHTS P-13, & P-14 AUXILLARY ROOF | | | DRAIN NEAR POOL SHALL NOT BE A TRIPPING | | | HAZARD. PLEASE SUBMIT A DETAIL FOR S/27, | | | S/28, S/29, & S/30 SECONDARY DRAINS. | | | SECTION 104.2.1. NO RESPONSE NOTED. SHT | | | VOIDED, BUT NO NEW SHEET SUBMITTED. | | | 38) SHT P-22 NO WATER SUPPLY SHOWN TO | | | THE TRASH ROOM FOR THE TRASH CHUTE. | | | PLEASE SHOW ON PLANS. SECTION 104.2.1. | | | NO RESPONSE NOTED. SHEET VOIDED, BUT NO | | | NEW SHEET SUBMITTED. | | | 39) SHTS P-24, P-25, P-26, P-27, & P-28 | | | DO NOT MEET CODE REQUIREMENTS. IN MANY | | | CASES THESE ARE THE CODE ISSUES NOT | | | ADDRESSED. - THESE COMMENTS NOW APPLY TO | | | SHTS 23, 29, 30, & 31 AS NEW RISERS HAVE | | | BEEN SUBMITTED, AND SHEET INFORMATION | | | HAS CHANGED. | | | A. OFFSET VENTS ARE REQUIRED WHEN | | | HORIZONTAL OFFSET ARE USED. SECTION 915. | | | RESPONSE NOT APPROVED. OFFSET VENTS | | | SHALL BE SHOWN ON THE RISER DIAGRAMS. | | | SEE SECTION 104.2.1. | | | B. NO HORIZONTAL DRY VENTS. SECTION | | | 905.3. | | | C. STACK DRAIN SHALL CONNECT DOWNSTREAM | | | OF BATHROOM GROUP FIXTURES. SECTION | | | 909.1 | | | D. KITCHEN SINK SHALL NOT DRAIN THROUGH | | | THE WET VENT. SECTION 909.1 | | | E. MAIN VENT REQUIRED AT TOP OF STACKS. | | | SECTION 903.1. | | | F. CLEANOUTS REQUIRED AT THE BASE OF | | | EACH STACK. SECTION 708.3.4. | | | G. NO HORIZONTAL BRANCH CONNECTIONS TO | | | A HORIZONTAL STACK OFFSET. SECTIONS | | | 711.2 & 711.3. | | | H. VENTING REQUIRED 901.2.1. | | | I. (NEW COMMENT) EVERY VENT STACK SHALL | | | CONNECT TO THE BASE OF THE DRAINAGE | | | STACK. THE VENT STACK SHALL CONNECT AT | | | OR BELOW THE LOWEST HORIZONTAL BRANCH. | | | SECTION 903.4 | | | J. STACK INSTALLATION 910.2 | | | THE RISERS ARE NOT CLEAR AS TO THEIR | | | INTENT. CHECK ALL RISERS FOR CODE | | | REQUIREMENTS. | | | 40) SHTS P-24, P-25, P-26, P-27, &P-28 | | | SANITARY RISER DIAGRAMS DO NOT REFLECT | | | THE FLOOR PLAN. THE FIXTURES FOR THE | | | MEZZANINE LEVEL ARE SHOWN ABOVE THE | | | MEZZANINE LEVEL, WHEN THE PIPING WILL BE | | | BELOW THE MEZZANINE LEVEL. FIXTURES FOR | | | THE SECOND FLOOR ARE SHOWN ABOVE THE | | | SECOND FLOOR WHEN THE PIPING WILL BE | | | BELOW THE SECOND FLOOR. THE FIXTURES FOR | | | THE THIRD THRU THE EIGHT FLOORS ARE | | | SHOWN BELOW THE TERRACE FLOOR. THE | | | PIPING SHOULD BE BELOW THE EIGHT FLOOR. | | | SECTION 104.2.1. - NO RESPONSE NOTED, | | | AND THIS COMMENT IS NOW FOR SHEETS P-23, | | | P-29, P-30, & P-31 AS NEW RISERS HAVE | | | BEEN SUBMITTED AND SHEET INFORMATION HAS | | | CHANGED. | | | 42) SHTS P-28 & P-29 SANT. BLDG. DRAIN | | | ISOMETRIC, SHOW ALL PIPE SIZES AND SHOW | | | THE DFU'S AS THEY ACCUMULATE IN THE | | | SYSTEM. SECTION 104.2.1. & TABLE | | | 710.1(1). - NO RESPONSE NOTED. PART OF | | | THE BLDG DRAIN ISOMETRIC HAS BEEN | | | DELETED AND THE ISOMETRIC IS INCOMPLETE. | | | PLEASE SUBMIT A COMPLETE ISOMETRIC. | | | 43) SHT P-31 AIR CHAMBERS ARE NOT | | | APPROVED. DELETE FROM ALL RISERS. WATER | | | HAMMER ARRESTORS REQUIRED BY SECTION | | | 604.9 SHALL BE LOCATED AT ALL QUICK | | | CLOSING VALVES, (W/M, ICE MAKER, & D/W), | | | AND SHALL BE LOCATED NEAR THE FIXTURE. | | | PDI-WH 201 AND MANUF. INSTALL. INSTRUCT. | | | NO RESPONSE NOTED. WATER RISER DIAGRAMS | | | HAVE CHANGED TO SHEETS P-35 & P-38. | | | 44) SHTS P-33 & P-34 AUXILLARY ROOF | | | DRAINS ON SOME SYSTEMS ARE UNDERSIZED. | | | PLEASE SIZE PIPE PER TABLE 1106.3. ROOF | | | DRAINS CHANGED TO SHTS 39, 40, 41, & 42, | | | AND STILL HAVE SOME AUXILLARY ROOF DRAIN | | | PIPING SIZED INCORRECTLY. | | | 45) SHT P-35 STORM DRAIN RISER 111, SHOW | | | ALL PIPE SIZES AND SQUARE FOOTAGE AS IT | | | ACCUMULATES IN THE SYSTEM. RECHECK ALL | | | PIPE SIZES PER TABLES 1106.2 & 1106.3 AS | | | SOME PIPE SIZES ARE INCORRECT. THERE ARE | | | STILL SOME PIPE SIZES THAT ARE | | | INCORRECT. RISER III CHANGED TO RISER II | | | AND MOVED TO SHT 41.1. | | | 46) SHT P-36 WATER HEATER DETAIL. | | | THERMAL EXPANSION CONTROL IS REQUIRED | | | PER SECTION 607.3.2. PLEASE INDICATE HOW | | | THIS WILL BE ACCOMPLISHED. NO RESPONSE | | | NOTED. | | | 47) SHT P-36 GENERAL PLUMBING NOTES: | | | #2 1/4"/FT FOR 2-1/2" & SMALLER PIPE. | | | TABLE 704.1. INDICATE ON NOTE. NO | | | RESPONSE NOTED. | | | #16 AIR CHAMBERS ARE NOT APPROVED. | | | DELETE SYMBOL & REFERENCE. SECTIONS | | | 604.9 AND 104.2.1. - NO RESPONSE NOED. | | | 49) SUBMIT A CONDENSATE DRAIN ISOMETRIC | | | WITH ALL PIPE SIZES, LOCATION OF RISER | | | CONNECTIONS, RISERS, TERMINATION POINT | | | OF THE RISERS (VENTS), AND INDICATE | | | WHERE THE CONDENSATE DRAINS TO THE | | | OUTSIDE OF THE BUILDING. SECTION | | | 104.2.1. | | | 50) SUBMIT RISERS AND BLDG ISOMETRIC FOR | | | THE EMERGENCY T&P VALVE DISCHARGE LINE | | | AND EHT EMERGENCY PAN DRAIN LINE FOR THE | | | WATER HEATERS. SHOW ALL PIPE SIZES FOR | | | ALL PIPING. SECTIONS 104.2.1, & | | | 104.3.1.1. | | | 51) PLANS DO NOT APPEAR TO BE 100% AND | | | MORE COMMENTS MAY FOLLOW ON THE NEXT | | | REVIEW DEPENDING ON THE RESPONSE OF THIS | | | REVIEW. - PLANS STILL ARE NOT 100% AND | | | MORE COMMENTS MAY FOLLOW. | | | **************NEW COMMENTS************** | | | 1B) NEW FLOOR LAYOUTS, NEW REVIEW | | | 2B) SHTS A27 THRU A32 ALL TYPICAL UNITS | | | SHOW CLEAR FLOOR SPACE FOR W/C'S PER | | | PAGE 7.43 FHA DESIGN MANUAL. SEE MINIMUM | | | CLEAR FLOOR SPACE SIZE REQUIREMENTS. - | | | SHOWER CLEAR FLOOR SPACE SHALL BE | | | PARALLEL AND FLUSH WITH THE CONTROL | | | WALL. SEE PAGE 7.56. | | | 3B) SHTS A27 THRU A32 ALL TYPICAL UNITS | | | WATER CLOSETS SHALL BE 18" OFF WALL TO | | | CENERLINE OF FIXTURE. SEE PAGES 6.5, | | | 7.43, 7.44 & 7.45. THIS IS WHEN THE W/C | | | IN NEXT TO A WALL. | | | 4B) SHTS A27 THRU A32 ALL TYPICAL UNITS | | | SHALL SHOW THE DIMENSIONS FOR THE W/C | | | OPENINGS. MINIMUM 33" REQUIRED. SEE | | | PAGES 7.43 THRU 7.45 | | | 5B) SHT A1 DRAWING INDEX DOES NOT | | | REFLECT DRAWING SHEETS. SECTION 104.2.1. | | | 6B) SHT P-3 8" PD(8393SF) TURNS INTO 8" | | | PD(8818SF) IN UNIT L/W-D-1, COL. LINE 6 | | | THEN BACK TO 8" PD(8393SF). CLARIFY. | | | SECTION 104.2.1. | | | 7B) MANY SHEETS ON FLOOR PLAN AND RISERS | | | FOR MANY UNITS STATES "ISLEND VENT SEE | | | DETAIL ON SHEET P-36 OR SHEET P-42. NO | | | NEW SHT 36 SUBMITTED, AND NO SHT 42 | | | SUBMITTED. PLEASE CLARIFY. SECTION | | | 104.2.1. | | | 8B) SHT P-3 15" REQUIRED FOR SANITARY | | | BLDG. DRAIN (3907 FU), 10" REQUIRED ON | | | SANITARY BLDG. DRAIN (1507 FU) COL. LINE | | | 5/I, 5" MIN. (231 FU) UNIT L/W-C-1. | | | TABLE 701.1(1). - STORM AND AUXILLARY | | | PIPING SIZE IS NOT CORRECT IN MANY | | | AREAS. CHECK PIPE SIZE PER TABLES 1106.2 | | | AND 1106.3. | | | 7B) SHT P-4 STORM DRAIN RISERS S14.2, | | | S14.3, & S14.4 NO PIPING TO STORM DRAIN | | | SHOWN. SECTION 104.2.1. STORM & | | | AUXILLARY PIPE SIZES INCORRECT, AND SOME | | | PIPE SIZES ARE NOT SHOWN. TABLES 1106.2 | | | & 1106.3 AND SECTION 104.2.1. | | | 8B) SHT P-4 UNITS L/W-E-2 & L/W-E-3 | | | WATER CLOSETS ARE NOT VENTED, AND | | | KITCHEN SINK AND FIXTURES FROM UPPER | | | FLOORS SHALL NOT DRAIN THROUGH BATHROOM | | | FIXTURES. SECTIONS 901.2.1 & 909.1 | | | 9B) THE FOLLOWING SHEETS HAVE BEEN | | | VOIDED, BUT NO NEW SHEETS HAVE BEEN | | | SUBMITTED. P-1, P-2, P-11 THRU P-22, | | | P-32, P-36, P-37, & P-42. PLANS | | | INCOMPLETE. SECTION 104.2.1. | | | 10B) SHT P-5 6" REQUIRED FROM PD(3080SF) | | | - 6" REQUIRED FROM PD(3719SF) - 6" | | | REQUIRED FROM PD(3361SF) - RISER 10, 11, | | | 16, 10.1, SHOW RISER DESIGNATION NUMBER | | | ON PLAN. TABLE 1106.3 & SECTION 104.2.1. | | | UNIT L/W-B-1 WASH MACHINE SHALL NOT | | | DRAIN INTO THE WET VENT FOR THE BATHROOM | | | FIXTURES. SECTION 909.1 | | | 11B) SHT P-6 5" MINIMUM REQUIRED PD | | | (2343SF), 6" REQUIRED PF(3080SF) SHOW | | | PIPING FOR PD(3061SF). TABLE 1106.3 AND | | | SECTION 104.2.1. - UNIT L/W-B-1 WASH | | | MACHINE SHALL NOT DRAIN INTO THE WET | | | VENT FOR THE BATHROOM FIXTURES. SECTION | | | 909.1. - RISER DIAGRAM DESIGNATION 56 IS | | | POINTING TO CONDENSATE LINE, NOT SANT. | | | RISER. - FLOOR PLAN DOES NOT REFLECT THE | | | RISER DIAGRAM (100). SECTION 104.2.1. | | | 12B) SHT P-7 6" REQUIRED ON AUXILLARY | | | DRAIN LINES AT RISERS S/28, & S/29. 5" | | | REQUIRED ON AUXILLARY DRAIN LINE BETWEEN | | | COL. LINES 5 & 7/D & C. 8" REQUIRED ON | | | AUXILLARY DRAINS S/8 & S/12. SHOW RISERS | | | 70 & 98 LOCATIONS ON FLOOR PLAN. - PIPE | | | SIZES NOT SHOWN FOR ROOF DRAINS, PRIMARY | | | AND SECONDARY FOR COMMON PATIO AND | | | PRIVATE LANAI AREAS. SECTION 104.2.1 AND | | | TABLE 1106.3. - UNITS C-3L MAX. 4 FU ON | | | 2" WET VENT TABLE 909.3. | | | 13B) SHT P-8 6" REQUIRED ON AUXILLARY | | | DRAINS S/26 & S/29. 8" REQUIRED ON | | | AUXILLARY DRAINS S/14, & S/18. SHOW ALL | | | PIPE SIZES FOR ROOM PRIMARY & SECONDARY | | | DRAINS AT COMMON PATIO AND PRIVATE LANAI | | | AREAS. TABLES 1106.2 & 1106.3. | | | 14B) SHT P-10 UNIT C-3L MAX. 4 FU ON 2" | | | WET VENT. TABLE 909.3 - BLDG DRAIN | | | ISOMETRIC ON VOID SHT P-28 HAS BEEN | | | DELETED. NEW SHEET DO NOT HAVE ALL THE | | | BLDG. DRAIN ISOMETRIC SHOWN AND IS | | | INCOMPLETE. SUBMIT A COMPLETE BLDG. | | | DRAIN ISOMETRIC AS REQUIRED IN SECTION | | | 104.3.1.1. SHOW ALL PIPE SIZES, | | | CLEANOUTS, RISERS ECT. SECTION 104.2.1. | | | 15B) SHT P-23 RISERS INDICATE TYPICAL | | | 3RD THRU 8TH FLOORS, BUT 3RD THRU 7TH | | | FLOORS ARE DIFFERENT FROM 8TH FLOOR AS | | | THE 8TH FLOOR SHOWS THE REVENTING. THIS | | | IS NOT TYPICAL ON 3RD THRU 7TH FLOORS. | | | SECTION 104.2.1. | | | 16B) ALL RISERS THAT SHOW RELIEF VENTS, | | | RELEIF VENTS ARE ONLY REQUIRED IN SOIL & | | | WASTE STACKS IN BUILDINGS HAVING MORE | | | THAN 10 BRANCH INTERVALS. THESE ARE NOT | | | REQUIRED. PLEASE DELETE FROM RISERS. | | | SECTIONS 104.2.1 & 914.1. | | | 17B) SHT P-23 RISER 3,4,5,6 DOES NOT | | | REFLECT THE FLOOR PLAN. SHT P-3 SHOWS | | | RISER 6 CONNECTING TO RISER 345 ON THE | | | FIRST FLOOR NOT AT THE MEZZ. LEVEL AS | | | SHOWN ON THE RISER. SECTION 104.2.1. - | | | SHT P-5 SHOWS ONLY RISER #8 WITH RISERS | | | 3,4,5,6 CONNECTING TO THIS RISER. | | | CORRELATE RISERS AND FLOOR PLAN. | | | 18B) SHT P-23 RISER #7 DOES NOT REFLECT | | | FLOOR PLAN ON SHT P-5 AT LAV. - RISER | | | #10/11/10.1 STARTS OFF ON THE FLOOR PLAN | | | SHT P-3 AS RISER 10/11/16, THEN CHANGES | | | TO 10/11/10.1. PLEASE CLARIFY. WHY WAS | | | 10.1 NOT SHOWN AT BASE OF RISER, & WHY | | | WAS RISER 16 NOT INDICATED ON SHT P-5 OR | | | ON SHT P-23 RISER DESIGNATION? SECTION | | | 104.2.1. | | | 19B) SHT P-23 RISER 16 SHOWS NOTHING, & | | | STOPS AT 2ND FLOOR. PLEASE CLARIFY. | | | RISER 10/11/16/10.1 SHOWS VENT RISER #7. | | | PLEASE CLARIFY. RISER DOES NOT REFLECT | | | FLOOR PLAN AT RISER 10 ON THE 2ND FLOOR. | | | CORRELATE RISER AND FLOOR PLAN. SECTION | | | 104.2.1. | | | 20B) TITLE BLOCK ON SOME SHEETS HAS | | | WHITE OUT ON THEM AND THIS IS NOT | | | APPROVED. SECTION 104.2.1.3 | | | 21B) SHTS P-23, P-24, P-25, P-26, P-27, | | | P-29, P-30, & P-31 CHECK ALL RISERS FOR | | | COMPLIANCE WITH SECTIONS 903.1, 903.4, | | | 915, MAKE SURE THEY REFLECT THE FLOOR | | | PLAN, 909.1, 909.3, RELIEF VENTS NOT | | | REQUIRED 914, 905.3, 708.3.4, 711.2, | | | 711.3, 901.2.1. 910.2 AS THERE ARE | | | NUMEROUS CODE VIOLATIONS AND ALL RISERS | | | HAVE NOT BEEN CHECKED ON REVIEW. PLANS | | | ARE MISSING FLOOR PLAN FOR NUMEROUS | | | RISERS AND CAN NOT BE CHECKED TO SEE IF | | | THEY REFLECT THE FLOOR PLAN. THESE WILL | | | ALL BE CHECKED NEXT SUBMITTAL. | | | 22B) SHT P-34 W/C NOT VENTED AT UNITS | | | L/W-E-2 & L/W-E-3 AND RISERS 96, 97, | | | 97.1, & 98 AND KITCHEN SINKS SHALL NOT | | | DRAIN THROUGH THE WET VENT OF THE | | | BATHROOM FIXTURES. 909.1 | | | 23B) SHT P-35 SHOW ALL PIPE SIZES, | | | DELETE AIR CHAMBERS, & SHOW ALL WATER | | | HAMMER ARRESTORS REQUIRED BY SECTION | | | 604.9. SECTION 104.2.1. | | | 24B) SHT P-38 AIR CHAMBERS NOT APPROVED. | | | DELETE FROM MENS AND WOMENS TOILET ROOMS | | | ON ROOF TERRACE LEVEL. 604.9 | | | 25B) SHTS P-39, P-40, P-41, & P-41.1, | | | CHECK ALL AUXILLARY DRAINS FOR CORRECT | | | SIZE. TABLE 1106.3 @ 4.5"/HR. | | | **************************************** | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. - | | | NO RESPONSE TO THIS REQUIRES LAST | | | SUBMITTAL. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-12-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-06 |
Time |
09:36 |
Rev Time |
33.00 |
| Received By |
kstevens |
Date |
2004-11-29 |
Time |
18:50 |
Sent To |
|
|
| Notes |
| 2004-12-06 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | FHA-98 DISIGN MANUAL | | | | | | 1) SHTS I-1 & I-2 FIRM LICENSE NUMBER | | | REQUIRED ON THE TITLE BLOCK, SIGNATURE | | | REQUIRED, AND PRINTED NAME REQUIRED. | | | FAC | | | 61G1-16.004(2)(5)(6, 61G1-16.003 AND FS | | | 481.219. - SUBMIT PROOF OF LEGAL | | | SIGNATURE IN THE FORM OF A DRIVERS | | | LICENSE, VOTERS REG. CARD ECT., AND | | | SUBMIT A SIGNED/SEALED/DATED NOTORIZED | | | LETTER WITH YOUR LEGAL SIGNATURE FOR | | | OUR | | | FILES. | | | 2)SHT I-1, AN RPZ BACKFLOW, INSTALLED | | | BY | | | A LICENSED PLUMBING CONTRACTOR IS | | | REQUIRED FOR THE IRRIGATION SYSTEM. | | | SHOW | | | LOCATION ON PLANS. SECTIONS 608.13.2 | | | AND | | | 104.2.1 | | | 3) SHTS A-11 & A-12 SHT INDEX STATES | | | PARITAL 3RD-7TH FLOOR PLAN 1, BUT NOTE | | | 5 | | | STATES 3RD-5TH FLOOR PLAN. PLEASE | | | CLARIFY. SECTION 104.2.1 | | | 4) SHTS A-9, A-15 SUBMIT CALCULATIONS | | | FOR PRIMARY AND SECONDARY ROOF DRAINS | | | PER SECTIONS 1106, AND 1107 AND ALL SUB | | | SECTIONS. SHOW SF OF EACH AREA WITH 1/2 | | | AREA OF ALL VERTICAL WALLS INCLUDING | | | PARAPETS AND ROOF AREA FROM ABOVE THAT | | | DRAINS ON TO THE ROOF ADDED TO THE | | | CALCULATIONS. SHOW THE LOCATION OF ALL | | | PRIMARY AND SECONDARY ROOF DRAINS AND | | | THE SCUPPERS. ALSO SEE SHTS A-17 & | | | A-18. | | | THIS APPLIES TO THE ROOF DECK AREAS. | | | 5) SHTS A-9 & A-15 SHOW THE LOCATION | | | AND | | | SIZE OF ALL SECONDARY ROOF DRAINS AND | | | THE SCUPPERS. SECTION 104.2.1. | | | 6) SHTS A-15 & A-16 SUBMIT CALCULATIONS | | | FOR MINIMUM FACILITIES PER TABLES | | | 1003.1 | | | AND 403.1. SHOW THE SF OF EACH COMMON | | | AREA AND TOTAL COMMON AREA IN | | | CALCULATIONS. | | | 7) ARCHITECTURAL SHEETS, THE DATE | | | PREPARED AND THE PRINTED NAME OF THE | | | PERSON RESPONSIBLE FOR THE DOCUMENT ARE | | | REQUIRED PER FAC 61G1-16.004(4)(6) AND | | | FS 481.2055 | | | 8) SHTS A30, A-31, & A-32 INDICATE | | | SPECIFICATION "A" OR "B" FOR EACH UNIT | | | OR BATHROOM AS REQUIRED ON PAGE 7.35 | | | FHA | | | DESIGN MANUAL. | | | 9) SHTS A30, A-31, & A-32 SHOW THE SIZE | | | OF THE OPENINGS FOR ALL COVERED WATER | | | CLOSETS. MINIMUM 33" REQUIRED. SEE | | | PAGES | | | 6.5 AND 6.7 FHA DESIGN MANUAL. - THE | | | 18" | | | FROM THE WALL TO THE CENTERLINE OF THE | | | W/C IS AN ABSOLUTE MEASURMENT. SEE | | | FIGS. | | | PAGE 6.3 AND 6.5 | | | 10) SHT A33 MENS & WOMENS RESTROOMS, | | | SHOW CLEAR FLOOR SPACE FOR EACH | | | ACCESSIBLE FIXTURE. SECTIONS 11-4.16.2, | | | 11-4.19.E, & 11-4.22.3. THE TURNING | | | AREA | | | SHALL BE SHOWN IN THE TOILET ROOM, NOT | | | IN THE ACCESSIBLE STALL. ALSO SHOW | | | WATER | | | CLOSED HEIGHT 11-4.16.3. GRAB HEIGHT | | | MAX | | | 36". SHOWN AS 48" ON DETAIL BEHIND W/C. | | | SHOW FLUSH CONTROL 11-4.16.5. SHOW | | | URINAL HEIGHT 11-4.18.2. THE CENTERLINE | | | OF THE W/C SHALL BE 18" TO THE WALL, | | | NOT | | | 20" AS SHOWN. (SEE FIG 28). FOR THE | | | LAVS | | | SHOW KNEE CLEARANCE 11-4.19.2, FOR THE | | | SHOWER SHOW CONTROLS 11-4.21.5, SHOWER | | | UNIT 11-4.21.6, AND CURB 11-4.21.8. | | | 12) SHT A33 DETAIL #1 IN BOTH MENS AND | | | WOMENS RESTROOM. THE DOUBLE LAVS TO BE | | | 34" IN HEIGHT AND HAVE A CLEARANCE OF | | | 29". SEE FIG 31 - SECTION 11-4.19.2 | | | 13) A DRINKING FOUNTAIN IS REQUIRED IN | | | THE COMMON AREA. SUBMIT A DETAIL | | | COMPLYING WITH SECTION 11-4.15 AND ALL | | | SUBSECTIONS & 11-4.1.3(10)(A) FOR THOSE | | | WHO HAVE DIFFICULTY BENDING OR | | | STOOPING. | | | 14) SHT A36 SHOW HEIGHT AND WIDTH OF | | | SCUPPER OPENINGS ON THE DETAIL. | | | 15) A PROFESSIONAL ENGINEER SHALL SIGN | | | HIS NAME. INITIALS ARE NOT APPROVED PER | | | THE RULING BY FBPE. SUBMIT AN EXAMPLE | | | OF | | | THE ENGINEERS LEGAL SIGNATURE BY WAY OF | | | DRIVERS LICENSE, VOTERS REG. ECT, AND A | | | SIGNED SEALED NOTORIZED LETTER | | | INDICATING YOUR LEGAL SIGNATURE FOR OUR | | | FILES. FAC 61G15.23.002(1)(2) AND FS | | | 471.025. - THIS IS FOR ALL ENGINEERED | | | SHEETS. | | | 16) ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME, LICENSE NUMBER AND | | | CERTIFICATE OF AUTHORIZATION NUMBER OF | | | THE ENGINEERING BUSINESS ON EACH SHEET. | | | FAC 61G15-23.002(2) | | | 17) SHTS P-1 & P-2 PD'S SIZING AND | | | PIPING SIZING NOT CORRECT FOR ALL PD'S. | | | RECHECK SIZING PER TABLES 1106.2 & | | | 1106.3 - SHOW ALL SF AND PIPE SIZES. | | | 18) SUBMIT MANUF. SPECIFICATION SHEETS | | | FOR ELEVATOR SUMP PUMPS AND THE STORM | | | WATER SUMP PUMPS. PUMPS INFORMATION | | | SHALL SHOW LISTING. SECTION 303.4 | | | 19) SHTS P-3, & P-4 STORM PIPE SIZING | | | NOT CORRECT AS WELL AS THE EMERGENCY | | | ROOF DRAIN PIPING (SECONDARY ROOF | | | DRAINS). SEE TABLES 1106.2 & 1106.3. NO | | | SF SHOWN FOR PD'S AT COL. LINE 5/G-F1 | | | AND COL. LINE 6/F-E2. PD BETWEEN COLS. | | | 8.1 & 8.3 NORTH OF STAIRWAY #2 NO ADDED | | | TO THE SYSTEM. DOUBLE CHECK ALL PIPE | | | SIZES AND SHOW ADDITION OF ALL SF AS | | | THEY ACCUMULATE IN THE STORM BLDG | | | DRAIN. | | | SECTION 104.2.1. | | | 20) SHT P-3 MANY UNITS INDICATE 1-1/2" | | | TRAP FOR THE W/M. MINIMUM 2" TRAP | | | REQUIRED. TABLE 709.1 | | | 21) SHT P-3 UNIT L/W-B-1 SHOWS 2" 2FU | | | FROM KIT. SINK, BUT CHANGES TO 4" 91 FU | | | DOWNSTREAM. PLEASE CLARIFY. SECTION | | | 104.2.1. | | | 22) SHT P-4 STORM RISER DIAGRAM, SF FOR | | | PD AT COL. LINES 10/C2, 12/C2, 11/E2, & | | | TRASH ROOM BY STAIR #3 NOT SHOWN. | | | PLEASE | | | INDICATE SF FOR EACH PER TABLES 1106.2 | | | AND 1106.3. SECTION 104.2.1 | | | 23) SHT P-4 UNITS L/W-E-2 & L/W-E-3 | | | FITTING NOT INSTALLED PER SECTION | | | 706.3. | | | EACH UNIT SHOWS 76 FU, BUT FLOOR PLAN | | | SHOWS 2 RISERS EACH UNIT ONE WITH 68 FU | | | AND THE OTHER WITH 76 FT. PLEASE | | | CLARIFY | | | 24) SHT P-4 MOST W/M'S SHOW 1-1/2" | | | TRAPS | | | BUT TABLE 709.1 REQUIRES 2" TRAPS. | | | 25) SHT P-4 UNABLE TO FIND SOME RISERS | | | SHOWN ON THE FLOOR PLAN. PLEASE SUBMIT | | | A | | | SANT. RISER DIAGRAM FOR EACH RISER | | | SHOWN | | | ON THE FLOOR PLAN. SECTIONS 104.2.1 AND | | | 104.3.1.1 | | | 26) ALL AAV'S INSTALLED BELOW THE 5TH | | | FLOOR SHALL HAVE A RELIEF VENT | | | INSTALLED | | | PER SECTION 607.3.2. (SHOW ON THE SANT. | | | RISER DIAGRAM). | | | 27) SHT P-5 CHECK ALL PIPE SIZING ON | | | THE | | | STORM SYSTEM AND SHOW ALL PIPE SIZES. | | | SECTION 104.2.1 AND TABLES 1106.2 AND | | | 1106.3. | | | 28) SHT P-5 UNIT L/W-B-4 W/C NOT | | | VENTED, | | | AND UNIT L/W-B-5 W/C AND TUB NOT | | | VENTED. | | | SECTION 902.1. | | | 29) SHT P-6 RECHECK ALL PIPE SIZES AND | | | SHOW ALL PIPE SIZES ON PLANS. - UNITS | | | L/W-B-4 AND L/W-A-1 W/C'S ARE NOT | | | VENTED. SECTION 902.1. | | | 30) ALL SHTS ALL AAV'S 4TH FLOOR AND | | | BELOW REQUIRE A RELIEF VENT. SECTION | | | 607.3.2. SHOW ON FLOOR PLAN AND SANT. | | | RISER DIAGRAM. SECTION 607.3.2. | | | 31) SHT P-8 UNIT C-5 W/C NOT VENTED 2ND | | | BATH. SECTION 902.1 - SHOW ALL STORM | | | PIPING SIZES. UNIT C-4L BATHROOM GROUP | | | CONNECTED TO VENT STACK. SHALL BE | | | CONNECTED TO DRAIN STACK. - STORM AT | | | COL | | | 10 BY THE M/B UNIT B-4 IS INCORRECTLY | | | IDENTIFIED. SECTION 104.2.1. | | | 32) SHT P-9 UNITS C-5 BATHROOM EITH | | | SIDE | | | OF STAIRWAY #2, W/C'S NOT VENTED AND | | | LAVS/TUBS ARE CONNECTED TO THE VENT | | | LINE | | | NOT THE DRAIN STACK AS REQUIRED. | | | 33) SHT P-10 UNITS C-5, C-6L &D-1A, W/C | | | NOT VENTED SECTION 902.1. LAV/TUB | | | CONNECTED TO THE VENT STACK, NOT THE | | | WASTE STACK AS REQUIRED. | | | 34) SHT P-11 AUXILLORY HORIZONTAL DRAIN | | | PIPE SIZE NO SIZED CORRECTLY. TABLE | | | 11106.3. | | | 35) THE TRASH CHUTE REQUIRES AN "N36" | | | VACUUM BREAKER FOR BACKFLOW PROTECTION. | | | SECTION 608.13.6. | | | 36) SHT P-12 AUXILLARY HORIZONTAL DRAIN | | | PIPE SIZE PER 1106.3. | | | 37) SHTS P-13, & P-14 AUXILLARY ROOF | | | DRAIN NEAR POOL CAN NOT BE A TRIPPING | | | HAZARD. PLEASE SUBMIT A DETAIL FOR S/27, | | | S/28, S/29, & S/30 SECONDARY DRAINS. | | | SECTION 104.2.1. | | | 38) SHT P-22 NO WATER SUPPLY SHOWN TO | | | THE TRASH ROOM FOR THE TRASH CHUTE. | | | PLEASE SHOW ON PLANS. SECTION 104.2.1 | | | 39) SHTS P-24, P-25, P-26, P-27, & P-28 | | | DO NOT MEET CODE REQUIREMENTS. IN MANY | | | CASES THESE ARE THE CODE ISSUES NOT | | | ADDRESSED. | | | A) OFFSET VENTS ARE REQUIRED WHEN | | | HORIZONTAL OFFSETS ARE USED. SECTION | | | 915 | | | B) NO HORIZ. DRY VENTS. SECTION 905.3 | | | C) STACK DRAIN SHALL CONNECT DOWNSTREAM | | | OF THE BATHROOM GROUP FIXTURES. SECTION | | | 909.1 | | | D) KITCHEN SINK SHALL NOT DRAIN THROUGH | | | THE WET VENT. SECTION 909.1. | | | E) MAIN VENT REQUIRED AT TOP OF STACKS. | | | SECTION 903.1. | | | F) CLEANOUTS REQUIRED AT THE BASE OF | | | EACH STACK. SECTION 708.3.4. | | | G) HORIZONTAL BRANCH CONNECTION TO A | | | HORIZONTAL STACK OFFSET. SECTIONS 711.2 | | | & 711.3. | | | H) VENTING REQUIRED 901.2.1 | | | I) STACK INSTALLATION 910.2 | | | THE RISERS ARE NOT CLEAR TO THEIR INTENT | | | AND THE USE OF TEE FITTINGS AS SHOWN ON | | | THE RISERS ARE NOT APPROVED. (BULL HEAD | | | TEES ARE SHOWN WHERE THE SEWAGE IS NOT | | | DIRECTED IN THE DIRECT OF FLOW. CHECK | | | ALL RISERS FOR CODE REQUIREMENTS. | | | 40) SHTS P-24, P-25, P-26, P-27, 7 P-28. | | | SANITARY RISER DIAGRAMS DO NOT REFLECT | | | THE FLOOR PLAN. THE FIXTURES FOR THE | | | MEZZANINE LEVEL ARE SHOWN ABOVE THE | | | MEZZANINE LEVEL WHEN THE PIPING WILL BE | | | BELOW THE MEZZANINE LEVEL. FIXTURES FOR | | | THE SECOND FLOOR ARE SHOWN ABOVE THE | | | SECOND FLOOR WHEN THE PIPING WILL BE | | | UNDER THE SECOND FLOOR. THE FIXTURES FOR | | | THE THIRD THRU THE EIGHT FLOOR ARE SHOWN | | | BELOW THE TERRACE FLOOR. SHOULD BE BELOW | | | THE EIGHT FLOOR. SECTION 104.2.1 | | | 41) NO INFORMATION CAN BE READ ON THE | | | ENGINEER'S SEAL. THE SEAL SHALL BE AN | | | IMPRESSION TYPE THAT IMPARTS THE | | | REQUIRED INFORMATION ON THE PLANS. FAC | | | 61G15-23.001(1) & FS 471.025 | | | 42) SHTS P-28 & P-29 SANT. BLDG. DRAIN | | | ISOMETRIC, SHOW ALL PIPE SIZES AND SHOW | | | THE DFU'S AS THEY ACCUMULATE IN THE | | | SYSTEM. SECTION 104.2.1 & TABLE | | | 710.1(1) | | | 43) SHT P-31 AIR CHAMBERS ARE NOT | | | APPROVED. DELETE FROM ALL RISERS. WATER | | | HAMMER ARRESTORS REQUIRED BY SECTION | | | 604.9 SHALL BE LOCATED AT ALL QUICK | | | CLOSING VALVES, (W/M, ICE MAKER, AND | | | DISH WASHER), AND SHALL BE LOCATED NEAR | | | THE FIXTURE. PDI-WH 201 & MANUF. | | | INSTALLATION INSTRUCTIONS. | | | 44) SHTS P-33 & P-34 AUXILLARY ROOF | | | DRAINS ON SOME SYSTEMS ARE UNDERSIZED. | | | PLEASE SIZE PER TABLE 1106.3. | | | 45) SHT P-35 STORM DRAIN RISER III, SHOW | | | ALL PIPE SIZES AND SQUARE FOOTAGE AS IT | | | ACCUMULATES IN THE SYSTEM. RECHECK ALL | | | PIPE SIZES PER TABLES 1106.2 & 1106.3 AS | | | SOME PIPE SIZES ARE NOT CORRECT. | | | 46) SHT P-36 WATER HEATER DETAIL. | | | THERMAL EXPANSION CONTROL IS REQUIRED | | | PER SECTION 607.3.2. PLEASE INDICATE HOW | | | THIS WILL BE ACCOMPLISHED. | | | 47) SHT P-36 GENERAL PLUMBING NOTES: | | | #2 1/4" FOR 2-1/2" & SMALLER PIPE. | | | TABLE 704.1 INDICATE ON NOTE. | | | #16 AIR CHAMBERS ARE NOT APPROVED. | | | DELETE SYMBOL & REFERENCE. SECTIONS | | | 604.9 AND 104.2.1. | | | 48) SUBMIT A WATER RISER DIAGRAM IN | | | ISOMETRIC FORM FOR THE BLDG WATER PIPING | | | SHOWING ALL PIPE SIZES, VALVES, WATER | | | HAMMER ARRESTORS, AND LOCATION OF ALL | | | RISER CONNECTIONS TO THE DISTRIBUTION | | | PIPING. | | | 49) SUBMIT A CONDENSATE DRAIN ISOMETRIC | | | WITH ALL PIPE SIZES, LOCATION OF RISER | | | CONNECTIONS, RISERS, TERMINATION POINT | | | OF THE RISERS (VENTS), AND INDICATE | | | WHERE THE CONDENSATE DRAINS TO OUTSIDE | | | OF THE BUILDING. SECTION 104.2.1. | | | 50) SUBMIT RISERS AND BLDG ISOMETRIC FOR | | | THE EMERGENCY T&P VALVE DISCHARGE LINE | | | AND THE EMERGENCY PAN DRAIN LINE FOR THE | | | WATER HEATER. SHOW ALL PIPE SIZE FOR ALL | | | PIPING. SECTIONS 104.2.1 & 104.3.1.1. | | | 51) PLANS DO NOT APPEAR TO BE 100% AND | | | MORE COMMENTS MAY FOLLOW ON THE NEXT | | | REVIEW DEPENDING ON THE RESPONSE OF THIS | | | REVIEW. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2005-08-31 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2005-08-31 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2005-08-31 |
Time |
16:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2005-07-26 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2005-07-26 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2005-07-26 00:00:00 | 1.PARKING RAMP TO ACCESS SECOND LEVEL OF | | | PARKING SHALL BE 12 FEET CLEAR ON EACH | | | DIRECTION. | | | 2. ALLEY SHALL BE 20 FEET CLEAR TO | | | ACCESS PARKING ENTRANCE. | | | 3. PLEASE REVISE CALCULATION OF OPEN | | | SPACE. TOTAL AMOUNT PROVIDED IS 3,796SF | | | AND REQUIRED AMOUNT IS 4,288SF. | | | 4. PLEASE DEFINE THE TYPE OF UNITS | | | PROVIDED ON THE FIRST FLOOR. RESIDENTIAL | | | USES REQUIRE TO BE 18 INCHES ABOVE | | | GRADE; LIVE/WORK TYPE MUST BE AT GRADE. | | | 5.PLEASE PROVIDE A SAMPLE FOR THE WINDOW | | | TINTING. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2005-05-12 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2005-05-11 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2005-05-11 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2005-05-12 00:00:00 | 1. LOADING DOCK IS LOCATED ON A DEAD END | | | ALLEY. PLEASE PROVIDE ALTERNATIVE EXIT | | | OR WIDEN THE ALLEY FOR A TWO TRAFFIC | | | WAY. | | | 2. SIDEWALK ON ROSEMARY AVENUE SHALL BE | | | MINIMUM 8 FEET WIDE. | | | 3. ENTRY DOORS FOR UNITS AT THE SOUTH | | | SIDE OF THE OPEN SPACE SHALL BE MODIFIED | | | TO FACE THE OPEN SPACE. | | | 4. PLEASE PROVIDE A TABLE TO CONFIRM | | | COMPLIANCE WITH 15% LANDSCAPE | | | REQUIREMENT FOR THE ROOFTOP TERRACE. | | | 5. TREES PLANTED ON ROSEMARY AVENUE | | | SHALL BE CONSISTENT WITH EXISTING TREES | | | ON THE SAME STREET. RECOMMENDED SPECIE: | | | CATHEDRAL OR HIGH RISE LIVE OAK. | | | 6. BANYAN BOULEVARD SHALL PROVIDE SHADE | | | TREES ALONG THE SIDEWALK. RECOMMENDED | | | SPECIE: DAHOON HOLLY. | | | 7.PLEASE DEFINE WHAT TYPE OF UNITS ARE | | | YOU LOCATING ON THE FIRST FLOOR | | | (RESIDENTIAL OR LIVE/WORK). | | | 8. PLEASE SHOW ACCESIBLE ROUTE FROM THE | | | PARKING GARAGE FOR THE TWO UNITS ON THE | | | SOUTH SIDE OF ROSEMARY AVENUE. | | | 9.LIVE/WORK TYPE UNITS MUST HAVE A | | | HANDICAP ADAPTABLE RESTROOM ON THE FIRST | | | FLOOR (ACCORDING TO THE FLORIDA BUILDING | | | CODE). | | | 10. ENTRANCE DOOR FOR LIVE/WORK TYPE | | | UNITS MUST BE MINIMUM 3 FEET. | | | 11.ARCHITECTURAL DESIGN GUIDELINES: | | | - FIRST FLOOR WINDOWS SHALL HAVE A KICK | | | PLATE BETWEEN 18 AND 42 INCHES MINIMUM. | | | - ARCHES ON THE TOP FLOOR ARE NOT | | | CONSISTENT WITH THE OVERALL BUILDING | | | DESIGN. PLEASE MODIFY AND ENHANCE THE | | | TREATMENT OF THE BUILDING TOP. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-11-24 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2004-11-24 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2004-11-24 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2004-11-24 00:00:00 | 1. FIRST FLOOR IS EXCEEDING THE MAXIMUM | | | 20 FEET FROM FINISHED FLOOR TO FINISHED | | | FLOOR ALLOWED BY ART. IV SECTION 94-113 | | | (A)(6). PLEASE MODIFY DIMENSION OR | | | PROCEED FOR DAC VARIANCE. | | | 2.PLEASE CONFIRM MEZZANINES ARE IN | | | COMPLIANCE WITH PEMISSIBLE PERCENTAGE OF | | | FLOOR AREA ACCORDING WITH THE CITY'S | | | BUILDING CODE. | | | 3.PLEASE REVISE LOCATION OF PROPERTY ON | | | SITE PLAN AND LANDSCAPE DRAWING TO | | | CONFIRM COMPLIANCE WITH MAXIMUM 5 FEET | | | SETBACK; AND OVERHANG OF BALCONIES ON | | | ROW. | | | 4.SIDEWALK SHALL BE A MINIMUM OF 8 FEET. | | | PLEASE CONFIRM COMPLIANCE WITH THIS | | | REQUIREMENT. | | | 5.PLEASE PROVIDE A TABLE TO SPEFIFY THE | | | NUMBER OF RESIDENTIAL UNITS AND THE | | | NUMBER OF PARKING SPACES PROVIDED. | | | 6. TRAVEL LANES IN PARKING GARAGE SHALL | | | BE 24 FEET WIDE MINIMUM. | | | 7. NORTH ELEVATION WAS NOT INCLUDED WITH | | | SUBMITTED DRAWINGS. | | | 8.PLEASE PROVIDE A TABLE TO CONFIRM | | | COMPLIANCE WITH OPEN SPACE REQUIREMENT. | | | 9.OPEN SPACE SHALL BE DESIGN ACCORDING | | | WITH OPEN SPACE DESIGN GUIDELINE; AND | | | SHALL INCLUDE SEATING AREA FOR THE | | | PUBLIC, LIGHTING AND AT LEAST ONE | | | DRINKING FOUNTAIN. | | | 10.PLEASE PROVIDE A TABLE TO CONFIRM | | | COMPLIANCE WITH 15% LANDSCAPE | | | REQUIREMENT FOR THE ROOFTOP TERRACE. | | | 11.ON ROOFTOP TERRACE, CLIMATE | | | CONTROLLED STRUCTURES ARE LIMITED TO THE | | | MINIMUM AREA NECESSARY TO ACCOMODATE | | | STRUCTURES THAT ARE SECONDARY AND | | | INCIDENTAL TO THE PRIMARY ROOFTOP | | | AMENITY. | | | 11. TREES PLANTED ON ROSEMARY AVENUE | | | SHALL BE CONISTENT WITH EXISTING TREES | | | ON THE SAME STREET. RECOMMENDED SPECIE: | | | CATHEDRAL OR HIGH RISE LIVE OAK. | | | 12. BANYAN BOULEVARD SHALL PROVIDE SHADE | | | TREES ALONG THE SIDEWAK. RECOMMENDED | | | SPECIE: DAHOON HOLLY. | | | 13.ARCHITECTURAL DESIGN GUIDELINES: | | | - DOOR OR WINDOWS SHALL BE CENTERED WITH | | | THE ASSOCIATED BALCONY. | | | - FISR FLOOR WINDOWS SHALL HAVE A KICK | | | PLATE BETWEEN 18 AND 42 INCHES MINIMUM. | | | - ARCHES ON THE TOP FLOOR ARE NOT | | | CONSISTENT WITH THE OVERALL BUILDING | | | DESIGN. | | | - CANTILEVERED BALCONIES SHALL EXTEND NO | | | MORE THAN 3 FEET FROM THE BUILDING | | | FACADE AND SHALL BE VISIBLY SUPPORTED BY | | | BRACKETS. | | | - ALL WINDOWS SHALL BE OPERABLE AS HUNG | | | OR CASEMENT. | | | | | | | | | |
|
|
|