Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-12-10 Cont ID  
Sent By lmartine Date 2004-12-10 Time 13:51 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-12-03 Cont ID  
Sent By jwitmer Date 2004-12-03 Time 09:28 Rev Time 1.10
Received By jwitmer Date 2004-12-03 Time 09:28 Sent To  
Notes
2004-12-03 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04110227
 ADD: 325 CLEMATIS ST
 CONT: FRANCON INC
 TEL: (954)444-1189
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL
 LETTER
 LISTING THE ORIGINAL REVIEW COMMENT
 NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR
 SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
  
 1) PLANS INDICATE A 2HR TENANT
 SEPERATION WALL WITH A NOTE THROUGH
 PENETRATIONS 1 HR. SEE 705.1.2 AND
 TABLE
 705.1.2. FOR RATING.
  
 2) EXISTING LOBBY, INDICATE LOCATION OF
 ELEVATOR AND STAIRS & RATING. PROVIDE
 THE RATING OF STORAGE BELOW STAIRS.
  
 3) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO
 THE
 AUTHORITY HAVING JURISDICTION. SUCH
 IDEN
 TIFICATION SHALL BE ABOVE ANY
 DECORATIVE
 CEILING CEILING AND IN CONCEALED
 SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 4) CORRECT GENERAL NOTE# 2 SEE FLAME
 SPREAD & SMOKE DEVELOPMENT FOR
 MERCANTILE UNSPRINKLERED , EXITS AND
 EXIT ACCESS TABLE 803.3
  
 5) THE REAR EXITING OF THE UNIT AND EXIT
 ACCESS CORRIDOR DO NOT MEET :
 1012.1.4. DURING ITS SWING, ANY DOOR IN
 A MEANS OF EGRESS SHALL LEAVE
 UNOBSTRUCTED AT LEAST 1/2 OF THE REQUIRE
 REQUIRED WIDTH OF AN AISLE, CORRIDOR,
 PASSAGEWAY, OR LANDING, NOR PROJECT MORE
 THAN 7" INTO THE REQUIRED WIDTH.
 THE DOORS LEADING FROM UPS AND THE DOORS
 OFTHE LANDLORD DO NOT MEET THIS CODE
 REQUIREMENT. SEE CODE REQUIREMENT FOR
 180 DEGREE HINGES.
  
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-12-09 Cont ID  
Sent By btrobaug Date 2004-12-09 Time 17:21 Rev Time 0.50
Received By btrobaug Date 2004-12-09 Time 16:47 Sent To B
Notes
2004-12-09 00:00:00TO LUIS DESK./WRT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-11-15 Cont ID  
Sent By dpalmer Date 2004-11-15 Time 16:53 Rev Time 0.33
Received By dpalmer Date 2004-11-15 Time 16:33 Sent To  
Notes
2004-11-15 00:00:00*********** UNSAT ***************
  
 1)NOTE: PLEASE SEE FIRE REVIEW COMMENTS
 AND POSSIBLE COMMENTS FROM OTHER TRADES
 WHICH MAY AFFECT ELECTRICALPLANS.
  
 2)NOTE: PLEASE SEE MISSING SIGN CIRCUIT
 REQUIRED PER 600.5
  
 3)NOTE: PLEASE HAVE RAISED SEAL FROM
 ARCH BE CLEAR AND VISABLE WITH ALL
 INFORMATION REQUIRED ON SEAL.
 FS 481.221
 PLEASE ALSO SEE FIRST NAME FOR ARCH
 APPEARS TO BE INITIALS. FS AND FAC
 REQUIRES LEGAL SIGNATURE. IF WHAT IS
 SHOWN IS LEGAL SIGNATURE, PLEASE PROVIDE
 AND SIGNED AND SEALED NOTORIZED LETTER
 FOR LEGAL SIGNATURE. THIS LETTER WILL BE
 PLACED IN OUR SIGNATURE FILE FOR ANY
 FUTURE REFERENCE.
 THIS VERIFICATION IS NEEDED DUE TO
 PROBLEMS WITH FORGERIES ON PREVIOUS
 PROJECTS.
 FAC 61G1-16.004, FS 481.221
  
  
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 ONLY INSERT NEW REVISED SHEETS INTO
 COMPLETE SETS FOR REVIEW AND STAMPING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2004-12-09 Cont ID  
Sent By lmartine Date 2004-12-09 Time 15:11 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2004-12-09 00:00:00 
  
 -SEE MIKES APPROVAL ON RE-SUB SHEET
 12/9/04
  
  
 L.MARTINEZ

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-11-12 Cont ID  
Sent By mcarsill Date 2004-11-12 Time 14:46 Rev Time 0.00
Received By mcarsill Date 2004-11-12 Time 14:46 Sent To  
Notes
2004-11-12 00:00:001) IS THE EXISTING OFFICE SPACE THE
 SAME OR A DIFFERENT TENANT SPACE.
  
 2) PLEASE EXPLAIN SECURITY GATE. WHEN
 IS IT DOWN, WHEN IS IT UP. WHEN
 DOWN CAN IT BE OPENED QUICKLY IN THE
 EVENT OF AN EMEREGNCY.
  
 3) PLEASE EXPLAIN CLASS C FLAMESPREAD
 IN A NON SPRINKLER OCCUPANCY. USUALLY
 EXITS SHALL BE CLASS A OR B IN EXITS,
 AND EXIT ACCESS AREAS. PLEASE EXPLAIN.
  
 4) THERE APPEARS TO BE AN EXISTING DOOR
 WHEN OPENED BLOCKS THE EXITWAY.
  
 5) PLEASE EXPLAIN NIGHT LOBBY.
  
 6) WHAT FIRE RATING IS PRESENT FOR
 THE EXISTING LOBBY (ELEVATOR AND STAIR
 NOT SHOWN )
  
 7) WHAT RATING IS PRESENT FOR THE
 STORAGE AREA LOCATED UNDERNEATH
 THE STAIRS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-12-09 Cont ID  
Sent By lmartine Date 2004-12-03 Time 15:25 Rev Time 0.00
Received By lmartine Date 2004-11-04 Time 14:10 Sent To  
Notes
2004-11-04 00:00:00TO COMM BD#57

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2004-12-01 Cont ID  
Sent By pkrauss Date 2004-12-01 Time 15:37 Rev Time 0.20
Received By pkrauss Date 2004-12-01 Time 15:30 Sent To  
Notes
2004-12-01 00:00:00PLAN SHEET E-2, NOTE INDICATES A/C
 EQUIPMENT AND DUCTWORK ARE EXISTING AND
 NO REVISIONS TO BE MADE AT THIS TIME.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.
  

Review Stop P PLUMBING
Rev No 1 Status N Date 2004-12-09 Cont ID  
Sent By lmartine Date 2004-12-09 Time 14:36 Rev Time  
Received By lmartine Date   Time   Sent To  
Notes
***NONE***