| 2004-11-03 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 04110174 |
| | ADD: 700 NORTHPOINT PKY |
| | CONT: PLAN REVIEW |
| | CHRISTOPHER BERGA |
| | TEL: (305)416-3180 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1STREVIEW |
| | ACTION: DENIED |
| | |
| | |
| | 1)PROVIDE NOC RECORDED WITH THE CLERK |
| | OF COURT BEFORE A PERMIT CAN BE ISSUED. |
| | |
| | 2)FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| | OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| | TESTING REPORTS,MISSING REPORTS ARE AS |
| | FOLLOWS: |
| | A) WINDOWS FIXED & OPERTABLE |
| | B) STOREFRONT |
| | C) DOORS |
| | D) LOUVERS |
| | E) ROOFING (TILE) |
| | PRODUCT APPROVALS SUBMITTED WITH PERMIT |
| | APPLICATION AFTER OCTOBER 1, 2003 ARE |
| | REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 3) PROVIDE POSITIVE & NEGATIVE |
| | PRESSURES |
| | FOR THE INTERIOR ZONES AND END ZONES, |
| | SHOW ON WINDOW AND DOOR ELEVATIONS |
| | SEE TABLE 1606.2B. |
| | IF MEAN ROOF HEIGHT IS OVER 30' USE |
| | TABLE 1606.2D FOR HEIGHT & EXPOSURE |
| | ADJUSTMENT COEFICIENTS. |
| | |
| | |
| | 4) FL. BLD CODE 1606.1.7 THE FOLLOWING |
| | INFORMATION RELATED TO WIND SHALL BE |
| | SHOWN ON THE CONSTRUCTION DRAWINGS, |
| | 1)- BASIC WIND SPEED, MPH |
| | 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| | CATEGORY |
| | 3)- WIND EXPOSURE |
| | 4)- INTERNAL PRESSURE COEFFICIENT, |
| | 5)- COMPONENTS & CLADDING, THE DESIGN |
| | WIND PRESSURES IN TERMS OF PSF. |
| | |
| | 5) FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, |
| | PLANS INDICATE THE USSE OF WIRE LATH & |
| | FRY REGLET ( REVELS) INDICATE HOW THE |
| | PAPER BACKING WILL BE INSTALLED AT THESE |
| | |
| | INTERSECTIONS, SEE ASTM C-1063.7.8.3.1. |
| | |
| | 6)FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, |
| | VARIOUS SHEETS OF PLANS INDICATE THE |
| | DELETION OF LOUVERS IN THE GABLE WALLS, |
| | PROVIDE CALCS FOR VENTILATION FOR ATTIC |
| | SPACE, SEE 2309.7.1. |
| | |
| | 7) FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, |
| | WILL ANY BRACING OCCUR ON THE GABLE |
| | ENDS? |
| | |
| | 8) SHEET A501 DETAIL# 3, INDICATES THE |
| | USE OF 15/32 APA PLYWOOD, WITH NAILING |
| | @ |
| | 6" O.C. EDGES AND 12" IN THE FIELD. SEE |
| | 2301.1.2 CHARTS 2306,2307,2308 AND |
| | 2309 ARE TO BE USED ONLY IN WIND AREAS |
| | WHERE WIND SPEEDS DO NOT EXCEED 100 |
| | MPH. |
| | PROVIDE ADDITIONAL INFORMATION FOR |
| | NAILING. |
| | |
| | 9) A502 DETAIL# 5, INDICATES A WINDOW |
| | FLUSH WITH WALL. NOTE IF NON-IMPACT |
| | WINDOWS ARE USED SHUTTERS WILL NEED TO |
| | STAY APPROX 2 1/2 " FROMGLAZING. |
| | ALSO SEE IMPACT STANDARD FOR CITY. |
| | |
| | 10) 1404.1.1 TRIM SHALL BE SECURED TO |
| | THE WALL WITH METAL OR OTHER APROVED |
| | BRACKETS OR FASTENERS.(EFIS TRIM). |
| | |
| | 11) |
| | ) FBC* 105.13.1SPECIAL INSPECTOR. |
| | A STRUCTURAL INSPECTION PLAN MUST BE |
| | SUBMITTED PRIOR TO THE ISSUANCE OF A |
| | BUILDING PERMIT. THREE COPIES OF THE |
| | PLANS AND OTHER DOCUMENTS WILL BE |
| | REQUIRED FOR PERMITTING PURPOSES. |
| | CALL HAROLD PISKURA @ (561)805-6711 TO |
| | CONFIRM A SPECIAL INSPECTOR WILL BE |
| | REQUIRED. |
| | |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |