Plan Review Details - Permit 04110150
Plan Review Stops For Permit 04110150
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-12-16 Cont ID  
Sent By jwitmer Date 2004-12-16 Time 07:27 Rev Time 0.55
Received By jwitmer Date 2004-12-16 Time 07:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-11-29 Cont ID  
Sent By jwitmer Date 2004-11-29 Time 08:58 Rev Time 0.77
Received By jwitmer Date 2004-11-29 Time 08:58 Sent To  
Notes
2004-11-29 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04110150
 ADD: 1601 FORUM PLACE# 610
 CONT: PASS INTERNATIONAL
 TEL: (561)239-0125
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL
 LETTER
 LISTING THE ORIGINAL REVIEW COMMENT
 NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR
 SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) EXISTING ENTRY DOOR TO COMPLY WITH:
 11-4.13.6 MANEUVERING CLEARENCES
 AT DOORS. MINIMUM MANEUVERING
 CLEARENCES
 AT DOORS THAT ARE NOT AUTOMATIC OR
 POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITH
 IN THE REQUIRED CLEARENCES SHALL BE
 CLEAR & LEVEL.SEE DISPROPORTIONATE
 COST.
 11-4.1.6(2) DUTY TO PROVIDE AN
 ACCESSIBLE PATH OF TRAVEL TO ALTERED
 AREAS SHALL BE DEEMED DISPROPORTIONATE
 TO THE OVERALL ALTERATION WHEN THE COST
 EXCEEDS 20 % OF THE COST OF THE ALTERA-
 TION TO THE PRIMARY FUNCTION AREA.
 (A)(I) AN ACCESSIBLE ENTRANCE
 (II) AN ACCESSIBLE ROUTE
 (III) AT LEAST ONE ACCESSIBLE REST-
 ROOM FOR EACH SEX OR A SINGLE
 UNISEX RESTROOM
 (IIII) ACCESSIBLE TELEPHONE
 (IV) ELEMENTS SUCH AS PARKING, STOR-
 AGE OR ALARMS.
  
  
 3) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-11-16 Cont ID  
Sent By dpalmer Date 2004-11-16 Time 06:49 Rev Time 0.33
Received By dpalmer Date 2004-11-16 Time 06:49 Sent To  
Notes
2004-11-16 00:00:00********** PROVISO/REVISION ***********
  
 1)NOTE: PLEASE SHOW ALL CIRCUITING ON
 PLANS AND CORRELATE WITH A PANEL
 SCHEDULE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW AND STAMPING BEFORE FINAL.
 IF ANY OTHER REVISIONS ARE DONE, PLEASE
 INLUDE ABOVE WITH THAT REVISIONS BEFORE
 ROUGH INSPECTION.
  
 IF THERE ARE ANY QUESTIONS, PLEASE DO
 NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2004-12-06 Cont ID  
Sent By lmartine Date 2004-11-12 Time 11:20 Rev Time 0.00
Received By lmartine Date 2004-11-12 Time 14:20 Sent To  
Notes
2004-11-12 00:00:001) DEMOLITION, RENOVATION, AND
 CONSTRUCTION TO COMPLY WITH NFPA 241.
  
 2) DEBRIS SHALL BE REMOVED FROM THE
 SITE DAILY.
  
 3) ENSURE ADEQUATE EMERGENCY LIGHTING
 IS PRESENT.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-12-08 Cont ID  
Sent By mjacobs Date 2004-12-08 Time 15:24 Rev Time 0.00
Received By mjacobs Date 2004-12-08 Time 15:24 Sent To B
Notes
2004-12-08 00:00:00SENT TO "JW" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-12-06 Cont ID  
Sent By lmartine Date 2004-12-06 Time 11:21 Rev Time 0.00
Received By lmartine Date 2004-11-04 Time 10:26 Sent To  
Notes
2004-11-04 00:00:00TO COMM BD#28

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-12-16 Cont ID  
Sent By pkrauss Date 2004-12-16 Time 12:47 Rev Time 0.55
Received By pkrauss Date 2004-12-16 Time 10:47 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-12-01 Cont ID  
Sent By pkrauss Date 2004-12-01 Time 07:20 Rev Time 0.45
Received By pkrauss Date 2004-12-01 Time 07:13 Sent To  
Notes
2004-12-01 00:00:00DENIED:
 PLANS ARE TO BE SIGNED BY THE PERSON
 WHO
 DESIGNED THE SYSTEM IN ACCORDANCE WITH
 THE EITY AMENDMENTS TO THE FLORIDA
 BUILIDNG CODE 104.2.SEE ATTACHED.
  
 PLANS ARE OTHERWISE CODE COMPLIANT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.