| Plan Review Stops For Permit 04110084 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-01-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-01-26 |
Time |
13:30 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2005-01-26 |
Time |
13:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-11-29 |
Time |
07:30 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2004-11-29 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2004-11-29 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04110084 | | | ADD: 901 N OLIVE AVE/ SUITE ??? | | | CONT: PALM COAST BUILDERS | | | TEL: (561)262-2226 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT | | | NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR | | | SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1)PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | PERMIT APPLICATION DOES NOT PROVIDE | | | WHAT | | | UNIT OR SUITE WORK IS TO COMPLETEED | | | UNDER THIS PERMIT? | | | | | | 3) PROVIDE CURRENT PROPERTY CONTROL | | | NUMBER SEE ATTACHMENT. | | | | | | 4) 704.2.1.4 CORRIDOR PARTITIONS, | | | SMOKE STOP PARTITIONS, HORIZONTAL EXIT | | | PART- ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 5) 1016.3.1. EXIT SIGNS: | | | EXIT SIGNS SHALL BE MARKED BY AN | | | APPROVED SIGN READILY VISIBLE FROM ANY | | | DIRECTION OF EXIT ACCESS. EVERY EXIT | | | SIGN SHALL BE SUITABLE ILLUMINATED BY A | | | RELIABLE LIGHT SOURCE. EXTERNALLY AND | | | INTERNALLY ILLUMINATED SIGNS SHALL BE | | | VISIBLE IN BOTH THE NORMAL & EMERGENCY | | | LIGHTING. | | | | | | | | | 6)TABLE 803.3 MINIMUM INTERIOR FINISH | | | CLASSIFICATION; PROVIDE INFORMATION | | | BASED ON INTERIOR FINISH REQUIREMENTS | | | BASED ON OCCUPANCY. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-12-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-07 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-07 |
Time |
16:58 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-09-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-17 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-17 |
Time |
08:52 |
Sent To |
PC |
|
| Notes |
| 2006-09-17 00:00:00 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE NOTES FROM PREVIOUS | | | REVIEW WHICH STATES TO CORRELATE RISER | | | AND PANEL SHOWN FOR SIZE ETC. | | | PLEASE SEE MLO, MCB?? | | | 106.1.2 FBC ADMIN SECT. | | | | | | 2) NOTE: THIS IS ONLY A NOTE, HOWEVER | | | PLEASE VERIFY THE OCP ON THE MAIN | | | DISCONNECT AS SHOWN. PLEASE SEE THE | | | EQUIPMENT GROUNDING CONDUCTOR FROM THE | | | MAIN TO THE SUB PANEL IS SHOWN 3 SIZES | | | ALRGER THAN NEEDED BASED ON THE OCP | | | SHOWN ON THE MAIN. 250.122 . | | | THIS IS OK, HOWEVER IF SHOWN LIKE THIS | | | ON RISER THEN THIS IS WHAT WILL BE | | | REQUIRED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REWVIEW. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-02-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-21 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-21 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2006-02-21 00:00:00 | *********** UNSAT *********** | | | | | | 1)NOTE: PLEASE SEE FS 481.221 WHICH | | | REQUIRES THE ARCHITECT TO ALSO DATE | | | PLANS WHEN SIGNING AND SEALING SAID | | | DOCUMENTS. | | | PLEASE SEE THIS IS NOTED AS "AS-BUILTS" | | | INSTEAD OF DATE? | | | PLEASE SEE COMMENTS BELOW | | | | | | 2)NOTE: PLEASE SEE AHU IS SHOWN ON A/C | | | LAYOUT BUT NOT ON ELECTRICAL? PLEASE | | | SHOW WITH CIRCUITING. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE CIRCUITING ON PLANS | | | DOES NOT CORRELATE WITH NOTE FOR | | | CIRCUITING OF EM/ EXT LTS. PLEASE SEE | | | 700.12E WHICH REQUIRES EM/EXT LTS TO BE | | | CIRCUITED TO THE LOCAL BRANCH CIRCUIT OF | | | NORMAL LIGHTING IN ANY ONE AREA. | | | PLEASE ALSO SEE PANEL SCHEDULE. | | | | | | 4)NOTE: PLEASESEE CIRCUIT ON SCHEDULE | | | MENTIONS LTS FO PANEL ROOM?? | | | PLEASE VERIFY WHAT THIS IS AS A PANEL | | | ROOM COULD NOT BE LOCATED ON PLANS. | | | | | | 5)NOTE: PLEASE CORRELATE THE RISER AND | | | PANEL SUBMITTED AS THESE ARE SHOWN WITH | | | DIFFERENT SIZES. | | | 215.5 | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW. PLEASE BE SURE TO SEE ANY | | | POSSIBLE COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT ELECTRICAL PLANS. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-02-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-03 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-02-03 |
Time |
17:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-14 |
Time |
13:44 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-01-14 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2005-01-14 00:00:00 | ************ UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE NOTES ON PREVIOUS | | | REVIEW FROM BLDG AND ELECTRICAL REVIEW. | | | ALL OLD/VOIDED SHEETS ARE TO BE REMOVED | | | FROM SETS AND ANY NEW SHEETS ARE TO BE | | | INSERTED INTO COMPLETE SETS FOR REVIEW | | | AND STAMPING. | | | | | | 2)NOTE: PLEASE SEE A PANEL SCHEDULE IS | | | NOW SUBMITTED, HOWEVER THIS PANEL | | | SCHEDULE DOES NOT INDICATE ANY WIRE | | | SIZES, OVER CURRENT PROTECTION FOR | | | CIRCUITS? ETC. | | | 215.5 | | | PLEASE ALSO SEE 700.12 E FOR CIRCUITING | | | OF EM/EXT LTS. THE BRANCH CIRCUIT | | | FEEDING THE UNIT EQUIPMENT SHALL BE THE | | | SAME BRANCH CIRCUIT AS THAT SERVING THE | | | NORMAL LIGHTING IN THE AREA AND | | | CONNECTED AHEAD OF ANY LOCAL SWITCHES. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-05 |
Time |
10:35 |
Rev Time |
33.00 |
| Received By |
dpalmer |
Date |
2004-11-05 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2004-11-05 00:00:00 | ******** UNSAT ********* | | | | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH A PANEL | | | SCHEDULE TO BE SUBMITTED.215.5 | | | | | | 2)NOTE: PLEASE CLARIFY OF SERVICE SHOWN | | | IS NEW OR EXISTING? | | | PLEASE SHOW LOCATION OF SERVICE/PANELS | | | ETC. | | | IF THIS A NEW SERVICE, THIS MAY OR MAY | | | NOT BE PERMITTED PER 230.2. | | | 230.72 ETC | | | PLEASE ALSO VERIFY AIC RATING SHOWN AT | | | 77,000, THIS DOES NOT SEEM TO BE A | | | NORMAL RATED SIZE.?? | | | 110.9 | | | | | | 3)NOTE: PLEASE SHOW ANY AND ALL NEW A/C | | | EQUIPMENT ALONG WITH REQUIRED | | | DISCONNECTS PER 440.11 ON ELECTRICAL | | | PLANS. | | | | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER | | | REVIEWERS WHICH MAY HAVE AN AFFECT ON | | | ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-03-03 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-03-03 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-03-03 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2006-03-03 00:00:00 | ******PROVISO****** | | | | | | | | | SUBMITTED AS REVISION SHOWING AS BUILT. | | | PLANS ARE NOT DATED. PLEASE SEE OTHER | | | COMMENTS. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLANS REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-01-25 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-01-25 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-01-25 |
Time |
11:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-12-01 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-12-01 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-12-01 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2004-12-01 00:00:00 | DENIED********************************** | | | ENIED*********************************** | | | NIED*********************************** | | | | | | 1) DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2) DEBRIS SHALL BE REMOVED FROM THE SITE | | | DAILY. | | | | | | 3) EXIT SIGNS AND EMERGENCY LIGHTS ARE | | | REQUIRED. | | | | | | 4) NFPA 101 LIFE SAFETY CODE 2000 | | | EDITION CH 38.3.3.2 INTERIOR WALL AND | | | CEILING FINISH COMPLYING WITH 10.2.3 | | | SHALL BE CLASS A OR CLASS B IN EXITS AND | | | IN ENCLOSED CORRRIDORS FURNISHING ACCESS | | | TO EXITS; AND CLASS A, CLASS B, OR CLASS | | | C IN OFFICE AREAS. | | | | | | | | | NATE MCCRAY, CAPTAIN | | | 561-835-2910 OR 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-12-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-01 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-01 |
Time |
16:54 |
Sent To |
E |
|
| Notes |
| 2006-12-01 16:55:01 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-09-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-08 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-08 |
Time |
13:52 |
Sent To |
E |
|
| Notes |
| 2006-09-08 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-01-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-26 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-26 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2006-02-17 00:00:00 | TO "COMM" BD#15 | | 2006-01-26 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-31 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-31 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2005-01-31 00:00:00 | TO "COMM BD#36/RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
P |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-10 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-10 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2005-01-10 00:00:00 | TO "COMM BD#32" /RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-02 |
Time |
07:00 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2004-11-04 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2004-11-01 00:00:00 | TO COMM BD#10 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2006-02-22 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-02-22 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-02-22 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2006-02-22 00:00:00 | NO CHANGES ON MECHANICAL | | | PLANS.HM.2/22/06 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-21 |
Time |
15:09 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-01-21 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2005-01-21 00:00:00 | PROVISO: | | | AUXILIARY DRAIN LINE SHALL TERMINATE AT | | | A CONSPICUOUS POINT PER 2001 | | | FBC(M)307.2.3. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-11-30 |
Time |
17:26 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-11-30 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2004-11-30 00:00:00 | DENIED: | | | 1.RETURN AIR JUMPER FROM RM #102 & 103 | | | IS NOT SIZED.PROVIDE DUCT AND GRILLE | | | SIZE.PER 2001 FBC(M)601.4 EXCEPTION | | | #1, RETURN AIR JUMPER SHALL BE A MINIMUM | | | OF 1 1/2 TIMES THE SQUARE INCHES OF | | | SUPPLY (12"). | | | | | | 2.RETURN AIR GRILLE FROM RM #103 IS | | | NOT SIZED.PLEASE REVISE. | | | | | | 3.PROVIDE OUTSIDE OUTSIDE AIR | | | CALCULATIONS PER 2001 FBC(M) TABLE | | | 403.3. | | | | | | 4.AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 FBC(M) | | | 307.2.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-02 |
Time |
06:59 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-12-02 |
Time |
06:59 |
Sent To |
|
|
| Notes |
| 2004-12-02 00:00:00 | NO PLUMBING PLANS/WORK SHOWN |
|
|