Plan Review Details - Permit 04110059
| Plan Review Stops For Permit 04110059 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-12-23 |
Time |
16:03 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-12-23 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-11-24 |
Time |
16:44 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2004-11-24 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2004-11-24 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04110059 | | | ADD: 2707 OKEECHOBEE BLVD | | | CONT: WASTE WATER MANAGEMENT | | | TEL: (561)718-3890 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | PROVIDE MANUFACTURES SPEC FOR SEALING & | | | PINNING OF 2" HIGH PREMANUFACRURED | | | CURB. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-12-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-27 |
Time |
10:22 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2004-12-27 |
Time |
10:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-05 |
Time |
08:39 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-11-05 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2004-11-05 00:00:00 | ********* UNSAT************ | | | | | | 1)NOTE: PLEASE CLARIFY IS EXISTING PANEL | | | IS LISTED FOR LOCATION.408.6,408.17 | | | PLEASE ALSO SUBMIT MORE INFORMATION ON | | | NEW RECYKE PANEL. HOW IS THIS FED? ETC. | | | PLEASE SUBMIT SPECS FOR THIS PANEL. | | | | | | 2)NOTE: PLEASE SHOW GFI PROTECTION FOR | | | ANY RECEPTS IN LOCATIONS PER 210.8 | | | PLEASE ALSO GFI PROTECTION FOR | | | SUMP-PUMP | | | CIRCUIT. | | | | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-12-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-20 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-20 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2004-12-20 00:00:00 | SENT TO "COMM BD#50 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-11-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-29 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2004-11-01 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2004-11-01 00:00:00 | TO COMM BD#11 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-01-14 |
Time |
13:05 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2005-01-14 |
Time |
10:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-11-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-29 |
Time |
08:00 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-11-29 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2004-11-29 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) INDICATE SOURCE OF MAKE UP WATER FOR | | | THE CAR WASH. AN RPZ BACKFLOW IS | | | REQUIRED IF WATER SERVICE TO CAR WASH IS | | | DIRECTLY CONNECTED TO POTABLE WATER. | | | SECTION 608.13.2 | | | 2) ANY PROTION OF THE DRAINAGE SYSTEM | | | INSTALLED UNDERGROUNG SHALL NOT BE LESS | | | THAN 2 INCHES. SECTION 710.3 - PROPOSED | | | 1 INCH LINE CONNECTION NOT APPROVED. | | | 3) TWO WAY CLEANOUT IS REQUIRED AS THE | | | SANITARY BLDG DRAIN EXITS THE SLAB. | | | SECTION 708.3.5 | | | 4) A TRAP IS REQUIRED FOR THE OVERFLOW | | | LINE TO THE SANITARY SEWER. SECTION | | | 1002.1 | | | 5) A VENT IS REQUIRED FOR THE OVERFLOW | | | LINE TO THE SANITARY SEWER. SECTION | | | 902.1 | | | | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
|
Account Summary | Usage Policy | Privacy Policy