| Plan Review Stops For Permit 04101262 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-06-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-06-28 |
Time |
15:55 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2005-06-28 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2005-06-28 00:00:00 | BATHROOM REVISION ON PAGE A-1 OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-04-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-04-01 |
Time |
08:12 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2005-04-01 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2005-04-01 00:00:00 | REVISION OKALANGE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-12-15 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-12-15 |
Time |
11:16 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2004-12-15 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-11-05 |
Time |
09:45 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2004-11-05 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2004-11-05 00:00:00 | DENIED | | | | | | | | | 1.DOORS IN HALLWAY AT BATHROOMS AND | | | HVAC CLOSET SHALL COMPLY WITH THE | | | FOLLOWING. | | | 1012.1.4. DURING ITS SWING, ANY | | | DOOR IN A MEANS OF EGRESS SHALL LEAVE | | | UNOBSTRUCTED AT LEAST 1/2 OF THE REQUIRE | | | REQUIRED WIDTH OF AN AISLE, CORRIDOR, | | | PASSAGEWAY, OR LANDING, NOR PROJECT MORE | | | THAN 7" INTO THE REQUIRED WIDTH. | | | | | | 2.PANTRY SINK HEIGHT SHALL COMPLY WITH | | | | | | FBC 11-4.24.2 ALSO KNEE CLEARANCE SHALL | | | COMPLY WITH FBC 11-4.24.3 | | | SHOW DETAIL ON PLANS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | | | | BUILDING PLAN REVIEW | | | ART LANGE | | | TEL: (561)805-6672 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-04-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-04 |
Time |
13:11 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-04-04 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2005-04-04 00:00:00 | REV'S FOR E-1, AND E-2 ONLY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-19 |
Time |
18:46 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-01-19 |
Time |
18:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-23 |
Time |
14:39 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-12-23 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2004-12-23 00:00:00 | *********** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE PERMIT APPLICATION IS | | | FOR 405 NORTHWOOD, RE-SUB SHEET MENTIONS | | | 403, PLANS INDICATE 403 ALSO AND LAND | | | FILE SHOWS ADDRESS AS BEING 405???? | | | PLEASE CORRELATE WHICH IS CORRECT. | | | | | | 2)NOTE: PLEASE SEE RESPONSE LTR MENTIONS | | | AN "ELECTRICAL" SIGN IS NOT GOING TO BE | | | INSTALLED, HOWEVER, 600.5 REQUIRES A | | | CIRCUIT AT FRONT LOCATION WHEATHER OR | | | NOT AN ELECTRICAL SIGN IS INSTALLED. | | | PLEASE ADJUST PLANS AND PANEL SCHEDULE. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-11-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-04 |
Time |
11:17 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-11-04 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2004-11-04 00:00:00 | ******* UNSAT ******** | | | | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | RATINGS ARE GIVEN FOR PANELS AND BRANCH | | | BRKRS. | | | | | | | | | 2 )NOTE: PLEASE SHOW LOAD CALCULATIONS, | | | PLEASE SHOW PER | | | 220.3,220.10,220.11,220.13 ETC. | | | PLEASE ALSO SHOW ALL CONTINOUS LOADS | | | AT 125% PER 215.3,230.42 | | | PLEASE ALSO SEE LARGEST MOTOR. | | | TRK LT LOADING TO BE SHOWN PER 220.12B | | | | | | 3)NOTE: PLEASE VERIFY NEW OR EXISTING | | | SIGN CIRCUIT. 600.5 | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWERS WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | INSERT ONLY NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-04-12 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-04-12 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-04-12 |
Time |
10:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-12-27 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-12-27 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-12-27 |
Time |
14:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-11-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-11-10 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-11-10 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2004-11-10 00:00:00 | 1) PLEASE PROVIDE PRESCRIPTIVE | | | STRENGTH REQUIREMENTS FOR HANDRAIL. | | | | | | 2) WILL ANY STORAGE BE PERMITTED | | | UNDERNEATH THE PLATFORM. ANY | | | MECHANICAL OR ELECTRICAL PLANNED | | | FOR UNDERNEATH THE PLATFORM. | | | | | | 3) SOFFITS ARE NOT TO INTERFERE | | | WITH ANY FIRE SPRINKLER HEADS. | | | | | | 4) PLEASE ILLUSTRATE ALL EXIT SIGNS | | | AND EMERGENCY LIGHTING. | | | | | | 5) PLEASE DISPLAY ALL PORTABLE | | | FIRE EXTINGUISHER LOCATIONS. | | | | | | 6) SEPARATE PLANS AND PERMITS | | | REQUIRED FOR FIRE ALARM AND FIRE | | | SPRINKLER REMODEL. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-27 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-27 |
Time |
16:52 |
Sent To |
B |
|
| Notes |
| 2005-06-27 00:00:00 | TO "ALANGE" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-03-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-31 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-31 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2005-03-31 00:00:00 | TO "COMM" BD#45 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-11 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-11 |
Time |
14:19 |
Sent To |
E |
|
| Notes |
| 2005-01-11 00:00:00 | TO "DP" DESK/RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-12-09 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-09 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-09 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2004-12-09 00:00:00 | SENT TO COMM BD#30 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-01 |
Time |
07:08 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2004-11-01 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2004-10-29 00:00:00 | TO COMM BD#4 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-05-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-05-02 |
Time |
15:05 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-05-02 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2005-04-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-04-25 |
Time |
14:29 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-04-25 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2005-04-25 00:00:00 | DENIED: | | | 1.PLANS INDICATE REVISIONS 1, 2, 3 AND | | | 4 BUT ONLY REVISION #4 IS INDICATED ON | | | PLAN SHEET AC-1 & AC-2. | | | | | | 2.PLAN SHEET AC-2 INDICATES HEIGHT FOR | | | THE CU STAND.DETAIL INDICATES "HEIGHT | | | OF LEGS".THIS SHOULD READ "MINIMUM | | | CLEARANCE ABOVE THE ROOF" WHICH MAY BE | | | GREATER THAN 14" DEPENDING ON THE ROOF | | | SYSTEM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-05 |
Time |
07:31 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-01-05 |
Time |
07:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-12-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-01 |
Time |
06:52 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-12-01 |
Time |
06:35 |
Sent To |
|
|
| Notes |
| 2004-12-01 00:00:00 | PROVISO: | | | CONDENSING UNIT STAND INDICATED ON PLAN | | | SHEET AC-2 INDICATES 18" FROM THE ROOF | | | DECK.PLEASE REFERENCE 2001 FBC 1511.7 | | | FOR PROPER CLEARANCE BETWEEN THE ROOF | | | SURFACE AND THE BOTTOM OF THE SUPPORT | | | RAIL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-05-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-05-03 |
Time |
09:50 |
Rev Time |
0.55 |
| Received By |
kstevens |
Date |
2005-05-03 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2005-05-03 00:00:00 | REVISION OK CHANGED KITCHEN FLOOR PLAN |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2005-04-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-04-25 |
Time |
09:14 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2005-04-25 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2005-04-25 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A-1 SHOW CLEAR FLOOR SPACE FOR | | | THE WATER COOLER. SECTION 11-4.15.5 | | | 2) SHT P-1 INDICATES REVISIONS 2, 3, & 4 | | | BUT ONLY REVISION NUMBER 4 WAS FOUND. | | | INDICATE ALL REVISIONS WITH CLOUDS AND | | | NUMBERED TRIANGLES TO EXPEDITE REVIEW. | | | SECTION 104.2.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-10 |
Time |
14:47 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-01-10 |
Time |
14:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-11-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-27 |
Time |
19:31 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-11-27 |
Time |
19:16 |
Sent To |
|
|
| Notes |
| 2004-11-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) ARCHITECTURAL SHEETS: PRINTED NAME OF | | | THE PERSON SEALING THE DOCUMENT IS | | | REQUIRED PER FAC 61G1-16.004(6) AND FS | | | 481.2055. | | | 2) SHOW CLEAR FLOOR SPACE FOR LAVS, | | | WATER CLOSETS, AND URINAL PER SECTIONS | | | 11-4.16.2, 11-4.18.3, 11-4.19.3, AND | | | 11-4.22.3. | | | 3) SUBMIT A DETAIL FOR THE PANTRY SINK | | | SHOWING COMPLIANCE WITH SECTION 11-4.24 | | | AND ALL SUBSECTIONS. | | | 4) A DRINKING FOUNTAIN IS REQUIRED PER | | | TABLE 403.1. ALSO SEE SECTION 410.1 | | | 5) SHT P-1 SANITARY RISER DIAGRAM AND | | | FLOOR PLAN FOR PIPING. THE SINK SHALL | | | NOT DRAIN THROUGH THE HORIZONTEL WET | | | VENT OF THE TOILET ROOMS. SECTION 909.1. | | | THE SINK SHALL CONNECT DOWNSTREAM OF THE | | | WET-VENTED FIXTURES. (SEE RED LINE | | | EXAMPLE ON ONE SET OF PLANS. | | | 6) SHT P-1 WATER RISER DIAGRAM, AIR | | | CHAMBERS ARE NOT APPROVED. SECTION | | | 604.9 | | | IF WATER HAMMER ARRESTORS ARE INSTALLED, | | | THEY SHALL BE LOCATED NEAR THE FIXTURE | | | IN AN "EFFECTIVE RANGE" NOT IN THE | | | CEILING. PDI-WH 210 AND MANUF. | | | INSTALLATION INSTRUCTIONS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|