| Plan Review Stops For Permit 04101252 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-07-13 |
Time |
07:03 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2005-07-13 |
Time |
07:03 |
Sent To |
|
|
| Notes |
| 2005-07-13 00:00:00 | TYPICAL WALL SECTION REVISION OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-03-03 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-03-03 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-02-16 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-02-16 |
Time |
15:53 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2005-02-16 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2005-02-16 00:00:00 | DENIED | | | | | | | | | | | | 2.PRODUCT APPROVALS REQUIRED FOR | | | EXTERIOR DOORS, WINDOWS, IMPACT | | | PROTECTION, STRAPS AND TIE-DOWNS AND | | | ROOFING.SUBMIT 2 COMPLETE SETS. | | | ALL PRODUCT APPROVALS WITH QUALITY | | | ASSURANCE REQUIRE THE FOLLOWING: | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 3. WATER STOP IS TO BE 1 1/2' PER | | | FBC AMMENDMENT 2111.1.9 REVISE DETAILS | | | A/S1 AND B/S1. | | | | | | 4.STRUCTURAL PAGES MISSING, CANNOT | | | COMPLETE REVIEW.SUBMIT 2 COMPLETE SETS | | | OF PLANS. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-07 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-12-07 |
Time |
14:22 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2004-12-07 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2004-12-07 00:00:00 | DENIED | | | | | | | | | 1.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 2.PRODUCT APPROVALS REQUIRED FOR | | | EXTERIOR DOORS, WINDOWS, IMPACT | | | PROTECTION, STRAPS AND TIE-DOWNS AND | | | ROOFING. | | | ALL PRODUCT APPROVALS REQUIRE THE | | | FOLLOWING: | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 3. WATER STOP IS TO BE 1 1/2' PER | | | FBC AMMENDMENT 2111.1.9 REVISE DETAILS | | | A/S1 AND B/S1. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-02-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-24 |
Time |
13:54 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-02-24 |
Time |
13:53 |
Sent To |
P |
|
| Notes |
| 2005-02-24 00:00:00 | REDLINED 410.8 ,210.52C1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-31 |
Time |
14:10 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-01-31 |
Time |
14:01 |
Sent To |
P |
|
| Notes |
| 2005-01-31 00:00:00 | ************ UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE FBC 104.2.1, ALL | | | PLANS ARE REQUIRED TO HAVE THE PRINTED | | | NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR PLANS/DESIGN. | | | PLEASE ALSO SEE ARCH SHEETS WHICH ARE | | | STILL MISSING REQUIRED TITLE BLOCKS AS | | | NOTED ON PREVIOUS REVIEW. | | | FAC 61G1-16.004, FS 481 | | | THIS IS REQUIRED ON ALL SHEETS AND FOR | | | ALL TRADES WEATHER OR NOT COMMENT IS | | | MADE BY OTHER REVIEWER(S). | | | | | | | | | 2)NOTE: PLEASE SHOW ALL RECEPTS | | | SERVING KITCHEN COUNTERSPACE AS GFI/GFI | | | PROTECTED PER 210.8A-6 | | | | | | 3)NOTE: PLEASE SEE MISSING SD LEADING TO | | | FLR ABOVE. PER NFPA-72 8-1.4.1.6.2 | | | | | | 4)NOTE: PLEASE SEE MISSING EGRESS | | | LIGHTING PER 210.70 | | | DOORS WITH GRADE LEVEL ACCESS. | | | | | | 5)NOTE: PLEASE SEE MISSING GFI FOR COND | | | UNITS. 210.63 | | | | | | 6)NOTE: PLEASE SEE MIN OCP FOR AHU'S PER | | | 424.3B MIN 125% | | | | | | 7)NOTE: PLEASE SEE MISSING RECEPT PER | | | 210.52 | | | | | | 8)NOTE: PLEASE PROVIDE ROOM DESIGNATIONS | | | ON PLANS. | | | | | | PLEASE SEE MOST OF THE ABOVE ITEMS ARE | | | REDLINED ON PLANS SUBMITTED FOR | | | REFERENCE OF ABOVE NOTES. | | | | | | PLEASE REMOVE ALL OLD VOIDED SHEETS AND | | | INSERT NEW SHEETS INTO TWO COMPLETE SETS | | | FOR ALL TRADES. | | | PLEASE SUBMIT ONE COPY OF OLD SHEETS FOR | | | REFERENCE. | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-12 |
Time |
22:02 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-11-12 |
Time |
22:02 |
Sent To |
P |
|
| Notes |
| 2004-11-12 00:00:00 | ********** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE NO ELECTRICAL PLANS | | | WERE SUBMITTED. | | | SUBMIT PLANS FOR WORK REQUIRED PER 2002 | | | NEC. | | | 104.2.14 | | | | | | 2)NOTE: PLEASE SEE FS 481.219 471.023, | | | FAC 61G1-16.004 AND FAC 61G15-23.002 FOR | | | MISSING TITLE BLOCK FOR ARCH AND MISSING | | | LICENSE INFORMATION FOR ENG FIRM. | | | THIS IS REQUIRED ON ALL SHEETS WHEATHER | | | OR NOT COMMENT IS MADE BY OTHER | | | REVIEWERS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-01-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-27 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-27 |
Time |
08:21 |
Sent To |
M |
|
| Notes |
| 2006-01-27 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-13 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-13 |
Time |
14:15 |
Sent To |
G |
|
| Notes |
| 2005-09-13 00:00:00 | TO "G" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-30 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-30 |
Time |
14:11 |
Sent To |
B |
|
| Notes |
| 2005-06-30 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-06-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-10 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-10 |
Time |
13:04 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-02-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-18 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-18 |
Time |
16:16 |
Sent To |
E |
|
| Notes |
| 2005-02-18 00:00:00 | TO DPALMER DESK/RESUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-01-26 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-26 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-26 |
Time |
16:19 |
Sent To |
E |
|
| Notes |
| 2005-01-26 00:00:00 | TO "DP"DESK/RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-01-25 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-25 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-25 |
Time |
07:22 |
Sent To |
Z |
|
| Notes |
| 2005-01-25 00:00:00 | TO "Z" BOX/RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-11-15 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-12 |
Time |
15:59 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-11-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-04 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-04 |
Time |
11:11 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-01-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-01-30 |
Time |
11:27 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-01-30 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2006-01-30 00:00:00 | REVISION TO MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-06-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-06-29 |
Time |
07:03 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2005-06-29 |
Time |
07:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-02-14 |
Time |
07:37 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2005-02-14 |
Time |
07:31 |
Sent To |
B |
|
| Notes |
| 2005-02-14 00:00:00 | HISTORIC |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-11-30 |
Time |
12:29 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-11-30 |
Time |
12:24 |
Sent To |
B |
|
| Notes |
| 2004-11-30 00:00:00 | DENIED: | | | MECHANICAL CONTRACTOR INDICATED ON THE | | | PERMIT APPLICATION.PLEASE PROVIDE THE | | | FOLLOWING; | | | | | | 1.FORM 600C PER 2001 FBC CHAPTER 13 | | | SUB-CHAPTER 6 METHOD C. | | | | | | 2.PROVIDE EQUIPMENT SCHEDULE. INDICATE | | | ON THE PLAN IF THE A/C EQUIPMENT IS NEW | | | OR EXISTING. | | | | | | 3.INDICATE NEW DUCT AND GRILLE SIZE | | | AND LOCATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-02-28 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-02-28 |
Time |
13:16 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-02-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-02-09 |
Time |
14:06 |
Rev Time |
0.41 |
| Received By |
kstevens |
Date |
2005-02-09 |
Time |
14:06 |
Sent To |
M |
|
| Notes |
| 2005-02-09 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | 1) ALL DRAWINGS SHALL BEAR THE NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR | | | THE DRAWINGS. SECTION 104.2.1. | | | (PLUMBING ISOMETRIC) | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-23 |
Time |
16:56 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-11-23 |
Time |
16:56 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2005-03-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-03 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2005-03-03 |
Time |
11:27 |
Sent To |
B |
|
| Notes |
| 2005-03-03 00:00:00 | OK PER MICHELLE, SEE SURVEY FOR APPROVAL |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2005-01-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-26 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-26 |
Time |
15:46 |
Sent To |
I |
|
| Notes |
| 2005-01-26 00:00:00 | DENIED, 2ND REQUEST FOR TWO COPY OF | | | SURVEY SHOWING ADDITION WITH SETBACKS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-11-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-11-12 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2004-11-12 |
Time |
12:50 |
Sent To |
I |
|
| Notes |
| 2004-11-12 00:00:00 | NOTE: DENIED, NEED TO PROVIDE TWO COPY | | | OF SURVEY SHOWING THE ADDITION WITH | | | SETBACKS.CALLED CONTR |
|
|