| Plan Review Stops For Permit 04101185 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-12-23 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-12-23 |
Time |
10:26 |
Sent To |
M |
|
| Notes |
| 2004-12-23 00:00:00 | BUILDING PROVISO | | | | | | 1) THE NOC HAS EXPIRED SUBMIT A NEW | | | NOC. | | | | | | 2) SUBMIT A REVISED KEY PLAN AND | | | INSTALLATION SCHEDULE FOR THE STORM | | | PANELS THAT MATCHS THE STRUCTURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-01 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-12-01 |
Time |
14:27 |
Rev Time |
3.50 |
| Received By |
lsmith |
Date |
2004-12-01 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2004-12-01 00:00:00 | BUILDING PLAN REVIEW FAILED | | | | | | 1. ACCORDING TO FS471.023 & FAC | | | 61G15.23.002 ALL TITLE BLOCKS MUST | | | INCLUDE THE CA# OF THE FIRM IN ADDITION | | | TO THE ENGINEER'S PE#.THE CA# IS NOT | | | SHOWN ON PLANS. THIS CAN BE HAND | | | WRITTEN. | | | | | | 2. A NOTICE OF COMMMENCEMENT MUST BE | | | FILED AT THE COUNTY CLERK OFFICE AND A | | | COPY SUBMITTED BEFORE A PERMIT CAN BE | | | ISSUED. | | | | | | 3. SUBMIT PROOF OF OWNERSHIP.OUR | | | RECORDS HAVE A DIFFERENT OWNER LISTED. | | | | | | 4. SEE NOTES FROM MECHANICAL REVIEW. | | | | | | 5. PAGE 6 PLANS NOTE FRONT DOORS TO BE | | | THERMA-TRU. PRODUCT APPROVALS SUBMITTED | | | FOR ANOTHER MFGR. CLARIFY. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 | | 2004-11-08 00:00:00 | NOTE: SPERATE PERMIT MUST BE PULLED FOR | | | POOL/SPA/DECK |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-08-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-26 |
Time |
17:18 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-08-26 |
Time |
17:18 |
Sent To |
|
|
| Notes |
| 2005-08-26 00:00:00 | REV'S, STAMPED OK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-08-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-12 |
Time |
06:38 |
Rev Time |
0.40 |
| Received By |
dpalmer |
Date |
2005-08-12 |
Time |
06:25 |
Sent To |
|
|
| Notes |
| 2005-08-12 00:00:00 | ****** UNSAT ******** | | | | | | 1)NOTE: PLEASE SHOW LOCATION OF POOL | | | PANEL ON PLANS. | | | PLEASE INCLUDE LOAD CALCULATION ON POOL | | | PANEL. | | | PLEASE SEE CONTINUOUS LOADS TO BE SHOWN | | | ON SUB PANEL. | | | 215.5,215.3,230.42,680.9 | | | | | | 2)NOTE: PLEASE SEE THERE ARE MANY | | | DEDICATED ITEMS LISTED ONPANEL | | | SCHEDULE WHICH ISD NOT SHOWN IN LOAD | | | CALCULATIONS, | | | PLEASE SEE OVEN, COOKTOP? GARAGE DR | | | OPENER,SPA TUB , BBQ FRIG, ETC. | | | 215.5,220.31 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-12 |
Time |
14:12 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-11-12 |
Time |
14:12 |
Sent To |
M |
|
| Notes |
| 2004-11-12 00:00:00 | ******** PROVISO/REVISION ********* | | | | | | 1)NOTE: PLEASE SEE MISSING RECEPT PER | | | 210.52 | | | | | | | | | 2 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 3)NOTE: PLEASE SEE HEAT PUMP WHICH IS | | | SHOWN ON LOAD CALCULATIONS IS NOT LISTED | | | ON PANEL SCHEDULE. PLEASE LIST, OCP, AWG | | | ETC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW AND STAMPING ALONG WITH ANY OTHER | | | REVISIONS BEFORE ROUGH ELECTRICAL | | | INSPECTION.IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-24 |
Time |
17:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-24 |
Time |
17:54 |
Sent To |
E |
|
| Notes |
| 2005-08-24 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-10 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-10 |
Time |
18:15 |
Sent To |
E |
|
| Notes |
| 2005-08-10 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-12-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-21 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-21 |
Time |
14:52 |
Sent To |
M |
|
| Notes |
| 2004-12-21 00:00:00 | SENT TO "M/AC" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-12-29 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-10-28 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2004-11-09 00:00:00 | TO SFD RACK/E | | 2004-10-28 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2004-11-18 |
Time |
08:05 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2004-12-29 |
Time |
11:26 |
Sent To |
B |
|
| Notes |
| 2004-11-18 00:00:00 | RETURN AIR DUCT MUST MATCH SUPPLY AIR | | | DUCT SIZE . MECH. 601.42001 FBC | | | | | | PAT RAFTER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2004-11-22 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2004-12-29 |
Time |
11:28 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-11-22 |
Time |
07:03 |
Sent To |
B1 |
|
| Notes |
| 2004-11-22 00:00:00 | NO PLUMBING PLANS SUBMITTED. SUBJECT TO | | | FIELD INSPECTORS APPROVAL. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-11-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-11-08 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-11-08 |
Time |
11:42 |
Sent To |
I |
|
| Notes |
| 2004-11-08 00:00:00 | NOTE: MUST PULL SEPERATE PERMIT FOR | | | POOL/SPA/DECK |
|
|