Plan Review Details - Permit 04101171
Plan Review Stops For Permit 04101171
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-12-23 Cont ID  
Sent By lmartine Date 2005-12-23 Time 14:17 Rev Time 0.00
Received By lmartine Date 2005-12-23 Time 14:17 Sent To  
Notes
2005-12-23 00:00:00RESTAMP PLANS

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-12-29 Cont ID  
Sent By lsmith Date 2004-12-29 Time 11:43 Rev Time 0.75
Received By lsmith Date 2004-12-29 Time 11:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-12-01 Cont ID  
Sent By lsmith Date 2004-12-01 Time 07:53 Rev Time 3.00
Received By lsmith Date 2004-11-30 Time 16:33 Sent To  
Notes
2004-11-30 00:00:00BUILDING PLAN REVIEW FAILED
  
 1. ACCORDING TO FS471.023 & FAC
 61G15.23.002 ALL TITLE BLOCKS MUST
 INCLUDE THE CA# OF THE FIRM SHOWN ON
 THE TITLE BLOCK IN ADDITION TO THE
 INDIVIDUAL ENGINEER'S PE #. THE CA# FOR
 WEYANT AND ASSOCIATES, INC. IS NOT
 INCLUDED ON THE PLANS. THIS CAN BE HAND
 WRITTEN.
  
 2. A NOTICE OF COMMENCEMENT MUST BE
 FILED AT COUNTY CLERK OFFICE &
 SUBMITTED
 BEFORE A PERMIT CAN BE PRINTED.
  
 3. NEED PROOF OF OWNERSHIP.
  
 4. THE FLORIDA ENERGY EFFICIENCY CODE
 SQ. FT. DOES NOT AGREE WITH THE PLANS.
 SEE LINES 6 & 10A.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-03-06 Cont ID  
Sent By dpalmer Date 2006-03-06 Time 07:30 Rev Time 0.00
Received By dpalmer Date 2006-03-06 Time 07:30 Sent To  
Notes
2006-03-06 00:00:00LTR FROM CONTRACTOR, JACUZZI OPTION NOT
 TAKEN.
 DEN OPTIONAL 4 RECESSED LTS NOT TAKEN.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-12-05 Cont ID  
Sent By dpalmer Date 2005-12-05 Time 08:41 Rev Time 0.00
Received By dpalmer Date 2005-12-05 Time 08:41 Sent To  
Notes
2005-12-05 00:00:00REDLINED,
 680.24 FOR GFI PROTECTION OF JACUZZI
 TUB.
 SHOWN ON PLANS, BUT NOT ON PANEL
 SCHEDULE OR LOAD CALCS.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-11-12 Cont ID  
Sent By dpalmer Date 2004-11-12 Time 13:43 Rev Time 0.33
Received By dpalmer Date 2004-11-12 Time 13:43 Sent To M
Notes
2004-11-12 00:00:00********** PROVISO/ REVISION ******
  
  
 1)NOTE: PLEASE SEE SOME MISSING RECEPTS
 PER 210.52
  
 2 )NOTE: PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
  
 **NOTE**
 ALL OPTIONS/ REVISIONS ARE TO BE
 SUBMITTED FOR REVIEW AND STAMPING
 BEFORE
 ROUGH**
  
 PLEASE SUBMIT THE ABOVE FOR REVIEW AND
 STAMPING BEFORE ROUGH.
 IF THERE ARE ANY QUESTIONS, PLEASE
 CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-12-22 Cont ID  
Sent By adarroug Date 2005-12-22 Time 15:03 Rev Time 0.00
Received By adarroug Date 2005-12-22 Time 15:03 Sent To B
Notes
2005-12-22 00:00:00TO "LMARTINEZ" DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-11-23 Cont ID  
Sent By adarroug Date 2005-11-23 Time 14:28 Rev Time 0.00
Received By adarroug Date 2005-11-23 Time 14:28 Sent To E
Notes
2005-11-23 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-12-21 Cont ID  
Sent By mjacobs Date 2004-12-21 Time 14:57 Rev Time 0.00
Received By mjacobs Date 2004-12-21 Time 14:57 Sent To M
Notes
2004-12-21 00:00:00SENT TO "M/AC" BOX.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-12-01 Cont ID  
Sent By lsmith Date 2004-12-01 Time 07:54 Rev Time 0.00
Received By lsmith Date 2004-10-28 Time 15:48 Sent To  
Notes
2004-11-09 00:00:00TO SFD RACK/E
2004-10-28 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-12-29 Cont ID  
Sent By drunnels Date 2004-11-18 Time 10:59 Rev Time 0.45
Received By prafter Date 2004-12-29 Time 10:59 Sent To B
Notes
2004-11-18 00:00:00A/C PLAN ,DOE'T MATCH BLDG. PLAN .
  
 R/A DUCT OUT OF MASTER BR. AREA SMALLER
 THAN SUP. AIR DUCT .
  
 MUST COMFORME TO 2001 FBC ,MECH. 601.4

Review Stop P PLUMBING
Rev No 1 Status N Date 2004-11-22 Cont ID  
Sent By prafter Date 2004-12-29 Time 11:09 Rev Time 0.25
Received By kstevens Date 2004-11-22 Time 07:09 Sent To B1
Notes
2004-11-22 00:00:00NO PLUMBING PLANS SUBMITTED. SUBJECT TO
 FIELD INSPECTORS APPROVAL

Review Stop Z ZONING
Rev No 1 Status P Date 2004-11-08 Cont ID  
Sent By mmclean Date 2004-11-08 Time 11:34 Rev Time 0.00
Received By mmclean Date 2004-11-08 Time 11:34 Sent To I
Notes
2004-11-08 00:00:00NOTE: MUST PULL A SEPERATE PERMIT FOR
 POOL/SPA/DECK