| Plan Review Stops For Permit 04101144 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-01-24 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2005-01-24 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2005-01-24 00:00:00 | BUILDING PLAN REVIEW: PROVISO | | | | | | CONTRACTOR TO SUBMIT 2 ORIGINAL SIGNED & | | | SEALED DRAWINGS FOR THE FOLLOWING: | | | | | | 1. BUTT GLASS IN CAFE | | | 2. FIXED GLASS (L) IN LIVING ROOM (3 | | | WINDOWS) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-01-03 |
Time |
14:51 |
Rev Time |
3.00 |
| Received By |
lsmith |
Date |
2005-01-03 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2005-01-03 00:00:00 | BUILDING PLAN REVIEW FAILED | | | | | | 1. SEE #7 OF FIRST REVIEW: DOOR #1 | | | SHOULD BEIMPACT DOORS. DOORS ARE AT | | | THE COVERED ENTRY. SUBMIT FLORIDA | | | PRODUCT APPROVAL FOR THE DOORS TO MEET | | | CODE FOR MEANS OF EGRESS IMPACT . | | | | | | 2. SEE#3 ON FIRST BUILDING REVIEW | | | REGARDING BUTT GLASS WINDOWS LOCATED IN | | | THE CAFE. DRAWINGS BY THOMAS M KALAHER | | | ARE NOT ORIGINAL. SUBMIT ORIGINAL | | | SIGNED, SEALED & DATED DRAWINGS FOR THE | | | BUTT GLASS WINDOWS. SUBMIT THE BACKUP | | | ARCH PRODUCT APPROVAL FROM DADE COUNTY. | | | | | | 3. THE ADDITIONAL FEES (NOTE #1) ARE | | | STILL UNPAID: $898.09 | | | | | | 4. THE PLANS HAVE TO BE TAKEN TO PBC | | | AND | | | IMPACT FEES PAID.THEY WILL STAMP THE | | | PLANS & ISSUE A RECEIPT. THE RECEIPT & | | | STAMPED PLANS MUST BE SUBMITED TO THE | | | CITY BEFORE A PERMIT CAN BE ISSUED. | | | | | | 5. FL253 PGT EXTERIOR DOOR PRODUCT | | | APPROVAL WAS SUBMITTED FOR THE FIRST | | | RESUB.WHERE ARE THESE DOORS LOCATED? | | | THEY ARE NONIMPACT AND WILL REQUIRE | | | STORMPANELS. | | | | | | 6. THE APPLICATION FOR PERMIT LISTS THE | | | OWNER AS DELCREST.OUR RECORDS SHOW | | | IBIS WEST PALM PARTNERS LP.SUBMIT A | | | WARRANTY DEED SHOWING THE CORRECT OWNER | | | SO WE CAN UP DATE OUR FILES. | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-02 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-12-02 |
Time |
10:38 |
Rev Time |
3.50 |
| Received By |
lsmith |
Date |
2004-12-02 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2004-12-02 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | 1.VALUE OF THE HOUSE HAS BEEN INCREASED | | | AND THE ADDITIONAL FEES ARE $898.09 | | | | | | 2. PLANS MUST BE TAKEN TO PBC AND IMPACT | | | FEES PAID.THE RECEIPT MUST BE | | | SUBMITTED BEFORE A PERMIT CAN BE | | | ISSUED. | | | | | | 3. SUBMIT ENGINEERING FOR THE BUTT GLASS | | | LOCATED IN THE CAFE. THE ARCHITECT OR | | | ENGINEER MUST PERFORM AN ON SITE | | | INSPECTION OF THE BUTT GLASS ASSEMBLY & | | | SUBMIT A LETTER SIGNED & SEALED STATING | | | IT HAS BEEN INSTALLED PER HIS | | | SPECIFICATIONS. THE PRODUCT APPROVAL WAS | | | NOT SUBMITTED. FLORIDA PRODUCT OR | | | LOCAL/SITE SPECIFIC REQUIRED. | | | | | | 4. THE GLASS BLOCK WILL REQUIRE | | | HURRICANE PROTECTION THE WINDOW SCHEDULE | | | DID NOT NOTE THE SHUTTERS WERE | | | REQUIRED. | | | | | | 5. THE GARAGE DOORS ON THE PLANS ARE ALL | | | THE SAME SIZE. THERE WERE TWO DIFFERENT | | | FLORIDA PRODUCT APPROVALS SUBMITTED. | | | REMOVE THE APPROVAL THAT DOES NOT APPLY. | | | THERE WERE SEVERAL COPIES OF TO FL605. | | | ONLY ONE PRODUCT APPROVAL IS REQUIRED | | | WHEN THERE ARE SEVERAL PRODUCTS OF THE | | | SAME KIND. THE OTHER PRODUCT APPROVAL IS | | | FL1822. | | | | | | 6. SUBMIT THE MANUFACTURERS | | | SPECIFICATIONS FOR THE GAS FIREPLACE IN | | | THE FAMILY ROOM. | | | | | | 7. SUBMIT THE FLORIDA PRODUCT APPROVAL | | | FOR THE 2 SINGLE LITE IMPACT FRENCH | | | DOORS SHOWN AS DOOR #1 IN DOOR | | | SCHEDULE. | | | | | | 8. THE SHUTTER SCHEDULE SHOWS DOOR #4 AS | | | A METAL DOOR NOT TO BE COVERED. PLANS & | | | DOOR SCHEDULE SHOW THE DOOR TO BE A | | | SINGLE LITE FRENCH DOOR TO BE COVERED | | | WITH STORM PANELS. PLEASE CLARIFY. | | | | | | 9. SUBMIT THE FLORIDA PRODUCT APPROVAL | | | FOR THE STRUCTURAL COMPONENTS (TRUSS | | | STRAPS, "USP" RT18F, HC10, RT20, ETC.) | | | SEE SHEET A-7. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 | | | | | | |
|
|
| Review Stop |
B1 |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-03-10 |
Time |
08:26 |
Rev Time |
0.25 |
| Received By |
lsmith |
Date |
2005-03-10 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2005-03-10 00:00:00 | LETER OF INTENT SUBMITTED. STILL NEED | | | PROVISO FOR 1/24/05. | | | | | | 1/24/05 PROVISO: | | | CONTRACTOR TO SUBMIT 2 COPIES SIGNED 7 | | | SEALED DRAWINGS FOR THE FOLLOWING: | | | 1. BUTT GLASS IN CAFE | | | 2. FIXED GLASS (L) IN LIVINGROOM (3 | | | WINDOWS) | | | | | | LS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-08 |
Time |
20:08 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-09-08 |
Time |
20:08 |
Sent To |
|
|
| Notes |
| 2005-09-08 00:00:00 | REDLINED WHAT IS A 4TH PANEL. THIS | | | SHOULD BE A LV PANEL. | | | OWES REV FEE, $60 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-30 |
Time |
17:36 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-06-30 |
Time |
17:36 |
Sent To |
|
|
| Notes |
| 2005-06-30 00:00:00 | REVISED PLANS. STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-06-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-15 |
Time |
14:24 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-06-15 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2005-06-15 00:00:00 | ************ UNSAT ***************** | | | | | | 1)NOTE: PLEASE CORRELATE LOAD SHOWN ON | | | PANEL "B" FOR POOL PANEL WITH LOAD SHOWN | | | ON POOL PANEL. | | | | | | PLEASE ALSO SEE LOAD SHOWN FOR PANEL "A" | | | AFTER DERATING, SHOWS LOAD EXCEEDING | | | RATING OF PANEL. PLEASE SEE 153.83A'S ON | | | A 150A PANEL. | | | | | | 240.4, ETC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-30 |
Time |
15:17 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-12-30 |
Time |
15:17 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-12 |
Time |
09:57 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-11-12 |
Time |
09:52 |
Sent To |
M |
|
| Notes |
| 2004-11-12 00:00:00 | ****** UNSAT ******* | | | | | | 1)NOTE: PLEASE SEE ARCH'S RAISED SEAL | | | MUST BE CLEAR AND VISABLE WITH ALL | | | INFORMATION REQUIRED. | | | FS 481.221 | | | THIS IS REQUIRED ON ALL SHEETS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICALPLAN REVIEW | | | 561-805-6717 | | | [email protected]. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-06-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-28 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-28 |
Time |
11:20 |
Sent To |
E |
|
| Notes |
| 2005-06-28 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-08 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-06-08 |
Time |
09:35 |
Sent To |
E |
|
| Notes |
| 2005-06-08 00:00:00 | TO 'DP' DESK/REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-03-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-07 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-07 |
Time |
10:15 |
Sent To |
B |
|
| Notes |
| 2005-03-07 00:00:00 | TO "LS"SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-01-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-13 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-13 |
Time |
10:02 |
Sent To |
P |
|
| Notes |
| 2005-01-13 00:00:00 | TO "P" BOX./RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-30 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-30 |
Time |
14:36 |
Sent To |
E |
|
| Notes |
| 2004-12-30 00:00:00 | TO :"DP" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-12-30 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-23 |
Time |
10:49 |
Sent To |
Z |
|
| Notes |
| 2004-12-23 00:00:00 | SENT TO "Z" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-02 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-12-02 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-10-28 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2004-11-08 00:00:00 | TO SFD RACK/E | | 2004-10-28 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-11-18 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2004-11-18 |
Time |
07:51 |
Rev Time |
0.45 |
| Received By |
drunnels |
Date |
2004-11-18 |
Time |
07:50 |
Sent To |
P |
|
| Notes |
| 2004-11-18 00:00:00 | PAT RAFTER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-01-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-22 |
Time |
13:20 |
Rev Time |
0.40 |
| Received By |
jleech |
Date |
2005-01-22 |
Time |
13:20 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-01-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-01 |
Time |
14:01 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-01-01 |
Time |
14:01 |
Sent To |
B |
|
| Notes |
| 2005-01-01 00:00:00 | DENIED; | | | W/M MUST DISCHARGE BELOW L/T. | | | I CANNOT FIND 3" F/D ON FLOOR PLANS. | | | WHAT PLUMBING FIXTURE DUMPS INTO THE | | | FLOOR DRAIN. HORIZONTAL DRY VENTS ARE | | | NOT TO CODE SEC.905.3 | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-11-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-09 |
Time |
18:57 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-11-09 |
Time |
18:49 |
Sent To |
E |
|
| Notes |
| 2004-11-10 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHT A-1 THE SANITARY RISER DIAGRAM | | | TAPED TO THE SHEET DOES NOT REFLECT THE | | | FLOOR PLAN, NOR DOES IT MEET CODE | | | REQUIREMENTS. | | | A) THE SHOWER IN BATH #2 IS NOT | | | VENTED. | | | SECTION 902.1 | | | B) THE WASH MACHINE SHALL CONNECT | | | DOWNSTREAM OF THE LAUNDRY SINK ON THE | | | RISER. SECTION 901.2 | | | C) A CLEANOUT IS REQUIRED 4' ABOVE THE | | | FLOOR ON THE WASH MACHINE RISER. | | | SECTION | | | 708.10 | | | D) SHOW ALL PIPE SIZES. SECTION | | | 104.2.1 | | | E) THE SANITARY RISER DIAGRAM DOES NOT | | | REFLECT THE FIXTURE OR PIPE LAYOUR ON | | | SHEET A-1. SINK AT SUMMER KITCHEN IS | | | NOT | | | SHOWN AND THE PIPING IS SHOWN ENTERING | | | THE HOUSE ON THE OPPOSITE END OF THE | | | HOUSE. IF THE PIPING IS BEING INSTALLED | | | FROM THE LEFT SIDE OF THE HOUSE THEN | | | THE | | | PIPING LAYOUT SHALL BE SHOWN TO REFLECT | | | THE PIPING AS IT WILL BE INSTALLED. | | | SECTION 104.2.1 - TAPEING THE RISER | | | DIAGRAM OVER INFORMATION FOR THE | | | FOUNDATION IS NOT APPROVED. SUBMIT NEW | | | SHEET WITH RISER DIAGRAM SHOWN ON THE | | | SHEET AND NOT COVERING OTHER INFORMATION | | | SECTION 104.2.1 | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-11-05 |
Time |
16:51 |
Rev Time |
3.50 |
| Received By |
mmclean |
Date |
2004-11-05 |
Time |
16:51 |
Sent To |
I |
|
| Notes |
|
|