| Plan Review Stops For Permit 04101133 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-12-29 |
Time |
16:04 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2004-12-29 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-03 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-12-03 |
Time |
15:36 |
Rev Time |
1.75 |
| Received By |
alange |
Date |
2004-12-03 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2004-12-03 00:00:00 | DENIED | | | | | | | | | 1.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 2.BUILDING IS IN A FLOOD ZONE.SUBMIT | | | 2 COPIES OF AN ELEVATION CERTIFICATE | | | SHOWING FINISH FLOOR HEIGHT AND BASE | | | FLOOD ELEVATION.FINISH FLOOR REQUIRED | | | TO BE SIX INCHES ABOVE BASE FLOOD | | | ELEVATION. | | | | | | 3.PLEASE SIGN OWNER/AGENT ON ENERGY | | | CALCS. | | | | | | 4.SHOW ON PLAN EXISTING BEDROOMS | | | ADJACENT TO ROOM ADDITION SO THAT | | | COMPLIANCE WITH EMERGENCY ESCAPE RESCUE | | | OPENING SIZES CAN BE CHECKED IF NEEDED. | | | FBC 1005.4.4 | | | | | | 5.SHOW ATTIC ACCESS SIZE AND LOCATION | | | COMPLYING WITH FBC 2309.6 | | | | | | 6.TRUSS NOTES #9 SHEATHING NAILING | | | SCHEDULE SHALL COMPLY WITH WPB | | | AMENDMENTS TO THE FBC 2306.1 | | | SHOW REVISED NAILING ON PLANS. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-12-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-16 |
Time |
14:37 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-12-16 |
Time |
14:26 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-12 |
Time |
18:44 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-11-12 |
Time |
18:44 |
Sent To |
P |
|
| Notes |
| 2004-11-12 00:00:00 | ********* UNSAT ************* | | | | | | 1)NOTE: PLEASE PROVIDE A PANEL SCHEDULE | | | AT THIS TIME SHOWING NEW MIN CIRCUITS. | | | PLEASE INCLUDE AWG, OCP, ETC | | | 215.5 | | | PLEASE INDICATE SIZE OF EXSITNG | | | SERVICE,PLANS NOTE: TO VERIFY? | | | THIS IS REQUIRED AT THIS TIME. | | | | | | 2)NOTE: PLEASE LIST ALL THE REQ'D | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3 | | | REQUIRED TO BE 20A, #12. | | | | | | 3)NOTE: PLEASE SEE LOAD CALCULATIONS, | | | PLEASE SEE 220.18 FOR MIN DRYER LOAD. | | | PLEASE INCLUDE ALL EXISTING LOADS ALONG | | | WITH NEW. | | | ** LOAD CALCS DO NOT INDICATE, ANY | | | PUMPS, WATER HEATERS, DISP, DISHWASHER, | | | FRIG, ETC ??220.3C1 | | | | | | 4)NOTE: PLEASE SEE 2002 NEC 210.12 FOR | | | THE REQUIRED ARC FAULT PROTECTION. | | | SD,LTS, FANS,RECEPTS,,,, | | | | | | 5)NOTE: PLEASE INCLUDE ALL INFORMATION | | | ON TITLE BLOCK AS REQUIRED UNDER FAC | | | 61G1-16.004. PLEASE SEE FS 481.219 FOR | | | REQUIRED CA #'S. | | | THIS IS REQUIRED FOR ALL SHEETS AND FOR | | | ALL TRADES WHEATHER OR NOT COMMEENT IS | | | MADE BY OTHER REVIEWER(S). | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE COPY OF OLD SHEETS SHOULD BE | | | SUBMITTED FOR REFERENCE ONLY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PELASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-14 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-14 |
Time |
08:20 |
Sent To |
E |
|
| Notes |
| 2004-12-14 00:00:00 | SENT TO "DP" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-11-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-09 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-09 |
Time |
10:18 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-10-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-29 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-29 |
Time |
14:26 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-11-29 |
Time |
15:08 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2004-11-29 |
Time |
15:08 |
Sent To |
P |
|
| Notes |
| 2004-11-29 00:00:00 | NO MECHANICAL PLANS OR CONTRACTOR | | | INDICATED WITH PERMIT APPLICATION. | | | FORM | | | 600C SUBMITTED WITH BUILDING PERMIT | | | APPLICATION.PLEASE PROVIDE PLANS WITH | | | MECHANICAL PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-12-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-30 |
Time |
10:12 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-12-27 |
Time |
15:53 |
Sent To |
B1 |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-11-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-22 |
Time |
18:41 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-11-22 |
Time |
18:41 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2004-12-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-12-13 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-12-13 |
Time |
16:30 |
Sent To |
I |
|
| Notes |
| 2004-12-13 00:00:00 | RESTAMP NEW PLANS NOTHING CHANGED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-11-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-11-10 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-11-10 |
Time |
11:42 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-11-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-08 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-11-08 |
Time |
12:42 |
Sent To |
I |
|
| Notes |
| 2004-11-08 00:00:00 | NOTE: DENIED, NEED CLARIFICATION ON WHAT | | | PLANS TO USE (SURVEY OR SITEPLAN) | | | SITEPLANS DOES NOT GIVE THE SETBACKS. | | | WOULD PREFER THE SURVEY THAT SHOWIS ALL | | | SETBACKS. NEED A COMPLETE FLOOR SHOWING | | | EXISITNG STRUCTURE AND SHOWING THE | | | ADDITION.ZONED SF7. CALLED CONTRACTOR. |
|
|