| Plan Review Stops For Permit 04101050 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-04-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-04-27 |
Time |
13:00 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-04-27 |
Time |
13:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-03-01 |
Time |
08:10 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2005-03-01 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2005-03-01 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04101050 | | | ADD: 2100 45TH ST # 143 | | | CONT:W P& S CONSTRUCTION | | | TEL: (954)444-6714 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1)PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)COMMENT #3 FROM THE PREVIOUS REVIEW, | | | PLANS ARE TO INDICATE A HANDICAPPED | | | ACCESSIBLE COUNTER: 11-5.2 COUNTERS AND | | | BARS, WHERE FOOD OR DRINK IS SERVED @ | | | COUNTERS EXCEEDING 34" IN HEIGHT FOR | | | CONSUMPTION BY CUSTOMERS SEATED ON | | | STOOLS OR STAND- ING AT THE COUNTER, A | | | PORTION OF THE MAIN COUNTER WHICH IS 60" | | | IN LENGTH MIN- IMUM SHALL BE PROVIDED IN | | | COMPLIANCE WITH 11-4.32 OR SERVICE SHALL | | | BE AVAIL- ABLE AT ACCESSIBLE TABLES | | | WITHIN THE SAME AREA. | | | | | | 3) COMMENT # 4 FROM THE PREVIOUS REVIEW, | | | THE DOOR TO THE RESTROOM DOESN'T MEET | | | THE MANEUVERING CLEARENCES, SEE: | | | 11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | | | | 4) TABLE 803.3 MINIMUM INTERIOR FINISH | | | CLASSIFICATION; PROVIDE INFORMATION | | | BASED ON INTERIOR FINISH REQUIREMENTS | | | BASED ON OCCUPANCY | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-11-24 |
Time |
15:56 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2004-11-24 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2004-11-24 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04101050 | | | ADD:2100 45TH ST# B-14 | | | CONT: WP&S CONTRACTORS | | | TEL: (954)444-6714 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1)PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) 704.2.1.4 CORRIDOR PARTITIONS, | | | SMOKE STOP PARTITIONS, HORIZONTAL EXIT | | | PART- ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 3) 11-5.2 COUNTERS AND BARS | | | WHERE FOOD OR DRINK IS SERVED @ COUNTERS | | | EXCEEDING 34" IN HEIGHT FOR CONSUMPTION | | | BY CUSTOMERS SEATED ON STOOLS OR STAND- | | | ING AT THE COUNTER, A PORTION OF THE | | | MAIN COUNTER WHICH IS 60" IN LENGTH MIN- | | | IMUM SHALL BE PROVIDED IN COMPLIANCE | | | WITH 11-4.32 OR SERVICE SHALL BE AVAIL- | | | ABLE AT ACCESSIBLE TABLES WITHIN THE | | | SAME AREA. | | | | | | 4) 11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | | | | 5)TABLE 803.3 MINIMUM INTERIOR FINISH | | | CLASSIFICATION; PROVIDE INFORMATION | | | BASED ON INTERIOR FINISH REQUIREMENTS | | | BASED ON OCCUPANCY | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-04-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-25 |
Time |
18:54 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-04-25 |
Time |
18:48 |
Sent To |
|
|
| Notes |
| 2005-04-25 00:00:00 | REDLINED | | | | | | ALL RECEPTS IN KITCHEN AREA TO BE | | | GFI/GFI PROTECTED. 210.8B3 | | | 2002 NEC | | | | | | PLEASE SEE NOC SUBMITTED HAS EXPIRED. | | | PER FS 713.13(2), IF WORKHAS NOT | | | COMMENCED WITHIN 90 DAYS OF RECORDING | | | NOC, NOC EXPIRES. | | | A NEW RECORDED NOC WILL BE REQUIRED | | | BEFORE PICKING UP PERMIT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-01 |
Time |
06:55 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-03-01 |
Time |
06:53 |
Sent To |
|
|
| Notes |
| 2005-03-01 00:00:00 | ********** UNSAT 2ND REVIEW ******** | | | | | | PLEASE SEE NOTES FROM PREVIOUS WHICH | | | STILL NEED TO BE ADDRESSED. | | | | | | 1)NOTE: OK. | | | | | | 2)NOTE: NOTE #2 NO. | | | | | | 3)NOTE: NOTE #3 NO. | | | | | | 4)NOTE: NOTE #4 NO. | | | | | | 5)NOTE: NOTE #5 NO. | | | | | | 1)NOTE: PLEASE SEE COPY OF FS | | | 553.80(2)(B) ATTACHED WITH RESPECT TO | | | DESIGN PROFESSIONAL. | | | PLEASE SEE ONE COPY OF ELECTRICAL PLANS | | | HAVE NOW BEEN RETAINED. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-11-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-02 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2004-11-02 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2004-11-02 00:00:00 | ************* UNSAT ****************** | | | | | | 1)NOTE: PLEASE CORRELATE | | | PLANS/PANEL/RISER. PLANS SHOWS 100A | | | PANEL, YET RISER ETC SHOWS 150A | | | | | | 2)NOTE: PLEASE CLARIFY EQUIPMENT | | | GROUNDING FROM MAIN TO PANEL. 250.110, | | | 250.122 | | | | | | 3) NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 4)NOTE: PLEASE IDENTIFY ALL RECEPTS IN | | | KITCHEN AREA AS GFI/GFI PROTECTED PER | | | 2002 NEC 210.8B3 | | | | | | 5)NOTE: PLEASE PROVIDE LOAD ON EXSITING | | | 1200A MAIN SHOWN. 215.5,220 | | | | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER | | | REVIEWERS WHICH MAY HAVE AN AFFECT ON | | | ELECTRICAL SHEETS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | | | | INSERT NEW SHEETS ONLY INTO TWO | | | COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-03-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-03-11 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-03-11 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-12 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-11-12 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2004-11-12 00:00:00 | 1) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATION FOR WALLS AND | | | CEILINGS. | | | | | | 2) SEPARATE PLANS AND PERMITS | | | FOR THE REQUIRED HOOD, DUCT, AND | | | SUPPRESSION SYSTEM. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2006-01-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-01-27 |
Time |
07:08 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2006-01-27 |
Time |
07:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-01-23 |
Time |
14:02 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2006-01-23 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2006-01-23 00:00:00 | DENIED; | | | A 2# TO 12" W.C. REGULATOR MUST BE | | | INSTALLED AFTER THE WATER HEATER BRANCH | | | AND WITHIN 60' OF THE LAST GAS APPLIANCE | | | TO MEET THE REQUIREMENTS OF THE FBC-2001 | | | FUEL GAS TABLE 402(2). THE REQULATOR FOR | | | THE WATER HEATER MUST BE A 2# BY 12" | | | W.C. WITH A SHUTOFF VALVE UP STREAM AND | | | A UNION DOWN STREAM OF THE REGULATOR. | | | SEE ONE PLAN MARKED IN RED. | | | GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-01-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-22 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-22 |
Time |
12:31 |
Sent To |
P |
|
| Notes |
| 2006-01-22 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-18 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-18 |
Time |
14:20 |
Sent To |
E |
|
| Notes |
| 2005-05-18 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-04-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-20 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-20 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2005-04-20 00:00:00 | TO "COMM" BD#33 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-22 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-22 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2005-02-22 00:00:00 | TO "COMM" BD#1 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-11-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-27 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2004-10-27 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2004-11-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | | | | 1) FIRST SHEET GENERAL NOTES #1 STATES | | | "STANDARD BUILDING CODE", ADOPTED CODE | | | IS THE FLORIDA BUILDING CODE-2001. | | | PLEASE UPDATE REFERENCE. | | | 2) PLANS SHALL BE ROUTED TO DBPR, STATE | | | OF FLORIDA DEPT. OF BUSINESS REGULATION, | | | DIVISION OF HOTEL AND RESTURANT FOR | | | REVIEW. SUBMIT 2 OR MORE SETS OF PLANS | | | STAMPED BY DBPR REVIEW WITH "WORKSHEETS" | | | ATTACHED FOR REVIEW. SECTION 101.4.7 | | | 3) GREASE INTECEPTOR SHALL BE SIZED BY | | | RODNEY COMPO, ENVIRONMENTAL COMPLIANCE. | | | A DETERMINATION SHEET FROM R. COMPO | | | SHALL BE ATTACHED TO PLANS WHEN | | | RESUBMITTING FOR REVIEW. CONTACT MR. | | | COMPO AT (561) 837-4074. WASTE ORD. | | | #2938-95 | | | 4) SEE ATTACHED SHEET FOR APPROVED | | | GREASE INTERCEPTOR DETAIL. | | | 5) SHT M1 0F 3 PLUMBING NOTES #1 | | | INDICATES STANDARD PLUMBING CODE, | | | APPROVED CODE IS FBC-2001 PLUMBING. | | | UPDATE REFERENCE. SECTION 104.2.1 | | | 6) SHT M1 OF 3 PLUMBING NOTES #8, 2-1/2" | | | AND SMALLER PIPE SHALL SLOPE 1/4" PER | | | FOOT. CORRECT PLUMBING REFERENCE. TABLE | | | 704.1 | | | 7) SHT M1 OF 3 PLUMBING NOTES #12 AIR | | | CHAMBERS ARE NOT APPROVED. DELETE FROM | | | REFERENCE. NOTE INDICATES THAT SHOCK | | | ARRESTORS ARE TO BE USED. IF SO SHOW ON | | | WATER RISER DIAGRAM. SECTIONS 604.9 AND | | | 104.2.1 | | | 8) AN RPZ BACKFLOW IS REQUIRED ON THE | | | WATER SERVICE. SECTION 608.13.2 | | | 9) TWO WAY CLEANOUTS ARE REQUIRED ON THE | | | INLET AND EXIT OF THE GREASE INTERCEPTOR | | | AND THE LIDS SHALL BE STAMPED WITH THE | | | WORDS "GREASE". (SEE ATTACHED SHEET). | | | 10) SHT M1 OF 3 STATES "NATIONAL FUEL | | | GAS CODE 1999 EDITION", THE ADOPTED CODE | | | FOR FUEL GAS IS FBC-2001 FUEL GAS. | | | PLEASE CHANGE REFERENCE. SECTION | | | 104.2.1 | | | 11 THE FOLLOWING INFORMATION IS REQUIRED | | | FOR THE GAS PERMIT REQUIRED . | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE.-NOT ALL LENGTHS ARE | | | SHOWN | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF USED. | | | C. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). | | | D. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | E. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | 2004-10-27 00:00:00 | TO COMM BD#20 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-05-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-05-17 |
Time |
18:09 |
Sent To |
|
|
| Notes |
| 2005-05-17 00:00:00 | PASS PRIVISO | | | NEED ADDITIONAL PERMITS FOR HOOD,HOOD | | | SUPRESSION, AND WALK IN COOLERS. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-03-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-03-12 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2005-03-12 00:00:00 | PLAN DENIED | | | 1) PROVIED OUT SIDE AIR CALCOLATIONS PER | | | 2001 FBC (M) 403.3 | | | 2) ADDITIONAL PERMITS REQUIRED FOR THE | | | HOOD,FIRE SUPPRESSION,GAS,WALK IN | | | COOLERS. | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-11-16 |
Time |
17:16 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-11-16 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2004-11-16 00:00:00 | DENIED: | | | 1.PROVIDE OUTSIDE AIR CALCULATIONS PER | | | 2001 FBC(M) 403.3. | | | | | | 2.PLAN SHEET M1 OF 3 INDICATES GAS | | | LOAD CALCULATIONS PER NATIONAL FUEL GAS | | | CODE 1999 EDITION.THIS SHOULD READ | | | 2001 FBC, FUEL GAS. | | | | | | ADDITIONAL PERMITS REQUIRED FOR THE | | | HOOD, FIRE SUPPRESSION, GAS, AND WALK-IN | | | COOLERS.PROVIDE PLANS & MANUFACTURER | | | SUBMITTAL DATA WITH PERMIT APPLICATION. | | | PROVIDE SUBMITTAL FOR THE CONVECTION | | | OVEN INDICATED ON M1 OF 3. | | | | | | 3.PLANS ARE TO BE APPROVED BY DBPR. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS @ (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-05-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-05-16 |
Time |
12:58 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2005-05-16 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2005-05-16 00:00:00 | PASSED/PROVISO | | | | | | WATER HAMMER ARRESTOR REQUIRED AT ICE | | | MAKER. | | | | | | APPROVED 2LB. TO 1/2LB. GAS REGULATOR | | | REQUIRED MAX. 50 FEET FROM MOST REMOTE | | | OUTLET FROM METER. | | | | | | REVISION REQUIRED FOR GAS RISER SHOWING | | | REGULATOR, AND MANUF. SPECIFICATION | | | SHEET FOR REGULATOR REQUIRED AT TIME OF | | | GAS ROUGH INSPECTION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-03-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-03-12 |
Time |
07:37 |
Rev Time |
2.00 |
| Received By |
jleech |
Date |
2005-03-12 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2005-03-12 00:00:00 | DENIED; | | | GAS RISER DIAGRAM; | | | SHOW ALL LENGHTS OF PIPE (SEE RED ) | | | IS GAS PIPE BLACK IRON OR GALV.,TREADED | | | OR WELD? | | | PRESSURE AT METER 1/2 LB OR 2 LB. | | | SUBMIT MANUFACTURES SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPIANCE SEC. 402.2 | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-11-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-27 |
Time |
17:45 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2004-11-27 |
Time |
17:45 |
Sent To |
|
|
| Notes |
| 2004-11-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A1 OF 3 GENERAL NOTES #1 STATES | | | "STANDARD BUILDING CODE", ADOPTED CODE | | | IS FBC-2001 BUILDING. PLEASE CHANGE | | | REFERENCE. SECTION 104.2.1 | | | 2) ROUTE THE PLANS TO DBPR DIVISION OF | | | HOTELS AND RESTURANT FOOD LICENSE | | | SERVICE FOR REVIEW. A MINIMUM OF 2 | | | STAMPED SETS SHALL BE RETURNED FOR | | | REVIEW WITH THE WORKSHEETS ATTACHED. | | | SECTION 101.4.7. | | | 3) GREASE INTERCEPTOR SHALL BE SIZED BY | | | RODNEY COMPO, ENVIRONMENTAL COMPLIANCE. | | | (561) 837-4074. ATTACH THE DETERMINE | | | SHEET FROM MR. COMPO TO PLANS WHEN | | | RESUBMITTING. WASTE ORD. #3928-95 | | | 4) SHT M1 OF 3 PLUMBING NOTES: | | | #1 STATES STANDARD BUILDING CODE - | | | ADOPTED CODE IS FBC-2001 PLUMBING. | | | CHANGE REFERENCE. SECTION 104.2.1 | | | #8 PIPE 2-1/2" AND SMALLER SHALL BE | | | SLOPED AT 1/4" PER FT. TABLE 704.1 | | | #12 AIR CHAMBERS ARE NOT APPROVED. | | | REMOVE FROM REFERENCE. SECTION 604.9 - | | | ALSO NOTE INDICATES THAT SHOCK ARRESTORS | | | WILL BE INSTALLED. SHOW THE SHOCK | | | ARRESTORS ON THE WATER RISER, PER PDI-WH | | | 201 AND MANUF. INSTALLATION | | | INSTRUCTIONS | | | 5) SHT M1 OF 3 GREASE TRAP DETAIL, TWO | | | WAY CLEANOUTS ARE REQUIRED AT THE INLET | | | AND THE OUTLET SIDES OF THE GREASE TRAP. | | | THE LIDS SHALL BE STAMPED "GREASE". SEE | | | ATTACHED UTILITY WPB GREASE TRAP | | | DETAIL. | | | 6) THE FOLLOWING INFORMATION IS REQUIRED | | | FOR THE GAS PERMIT. | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. - NOT ALL LENGHT OF PIPE | | | ARE SHOWN. | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | C. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). | | | D. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | E. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | 7) SUBMIT A DETAIL FOR THE ACCESSIBLE | | | TOILET ROOM PER SECTIONS 11-4.16, | | | 11-4.19, & 11-4.22 AND ALL SUBSECTIONS. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|