Plan Review Details - Permit 04101019
Plan Review Stops For Permit 04101019
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2006-07-11 Cont ID  
Sent By alange Date 2006-07-11 Time 09:29 Rev Time 0.50
Received By alange Date 2006-07-11 Time 09:29 Sent To  
Notes
2006-07-11 00:00:00WALL REVISIONS OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-07-06 Cont ID  
Sent By alange Date 2006-07-06 Time 08:08 Rev Time 1.00
Received By alange Date 2006-07-06 Time 08:08 Sent To  
Notes
2006-07-06 00:00:00EXTERIOR WALL/FENCE REVISION OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-02-01 Cont ID  
Sent By alange Date 2005-02-01 Time 09:18 Rev Time 1.00
Received By alange Date 2005-02-01 Time 09:18 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-01-06 Cont ID  
Sent By alange Date 2005-01-06 Time 15:41 Rev Time 1.00
Received By alange Date 2005-01-06 Time 14:37 Sent To  
Notes
2005-01-06 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 3.PRODUCT APPROVALS:
 PREMDOR ENTRY DOOR NEED SECOND COPY OD
 QULITY ASSURANCE AND NEED 2 COPIES OF
 STATE APPROVAL.
 SUBMIT 2 COPIES OF GARAGE DOOR QUALITY
 ASSURANCE.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 4. BASED ON SBCCI BUILDING VALUATION
 DATA, THE BUILDING VALUATION HAS CHANGE
 TO $82,270.00ADDITIONAL PERMIT FEES OF
 $494.55 ARE DUE.
  
 6.FBC WPB AMMENDMENTS 2306.1 SHOW
 SHEATHING FASTENING COMPLYING WITH THIS
 SECTION.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-12-03 Cont ID  
Sent By alange Date 2004-12-03 Time 10:03 Rev Time 1.50
Received By alange Date 2004-12-03 Time 07:55 Sent To  
Notes
2004-12-03 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SUBMIT TWO COPIES OF PRODUCT
 APPROVALS FOR EXTERIOR DOORS, FIXED
 GLASS WINDOWS AND OVER HEAD DOOR.
 ALL PRODUCT APPROVALS REQUIRE THE
 FOLLOWING TO BE ATTACHED.
 {SEE SHEETS I ATTACHED TO MIAMI-DADE
 APPROVALS}
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 4.BASED ON SBCCI BUILDING VALUATION
 DATA, THE BUILDING VALUATION HAS BEEN
 CHANGED FROM $42000 TO $82,270.00.
 ADDITIONAL PERMIT FEES ARE DUE.
  
 5.SHOW SIZES OF BEDROOM WINDOWS
 INCLUDING SILL HEIGHT FROM FLOOR FOR
 SOUTH BEDROOM.FBC 1005.4.4 EMERGENCY
 ESCAPE & RESCUE OPENINGS.
  
 6.SHOW ROOF AND WALL SHEATHING NAILING
 SCHEDULE.
  
 7.SHOW HOW SMOKE DETECTORS AND GFCI
 OUTLETS WILL COMPLY WITH FBC
 3401.7.1.2.1
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2006-07-17 Cont ID  
Sent By dpalmer Date 2006-07-17 Time 17:24 Rev Time 0.00
Received By dpalmer Date 2006-07-17 Time 17:23 Sent To PC
Notes
2006-07-17 00:00:00REV'S FOR FINAL.

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2006-07-05 Cont ID  
Sent By dpalmer Date 2006-07-05 Time 15:16 Rev Time 0.00
Received By dpalmer Date 2006-07-05 Time 14:36 Sent To B
Notes
2006-07-05 00:00:00*** UNSAT ***
  
 ** PLEASE SEE RISER IS NOW COMPLETELY
 DIFFERENT FROM PREVIOUS PLANS.
  
 1) NOTE: PLEASE INDICATE IF THE NEW
 PANEL "A" CONTAINS OCP FEEDING PANEL "C"
 OR DOES PANEL "A" CONTAIN FEED-THRU LUGS
 TO PANEL "C".
 215.5
  
 2) NOTE: PLEASE SEE SOME CIRCUITING ON
 PLANS EXCEED THE CIRCUITS SHOWN ON PANEL
 SCHEDULE "C". ( GDO).
 PLEASE ALSO KNOW THE GDO MAY NOT FEED
 OTHER ELECTRICAL LIGHTING/ DEVICES.
 430.31, TABLES 430.148
  
 3) NOTE: PLEASE SEE 408.4, AS THE PANEL
 SCHEDULES SHALL BE SPECIFIC ON BRANCH
 CIRCUITS. IE; BEDRM LTS, KITCHEN LTS,
 BATH LTS, LIV RM RECEPTS ETC.
  
 4) NOTE: PLEASE SEE KITCHEN PENINSULAR
 WHICH SHOWS A CIRCUIT "C-142' ?? WHAT IS
 THIS?
  
  
 ** PLEASE VERIFY THE FOLLOWING WHICH IS
 NOT A CODE VIOLATION, HOWEVER IF SHOWN
 THIS WAY ON PLANS, THEN THIS IS WHAT
 WILL BE REQUIRED.
 1) PLEASE VERIFY THE GEC ON RISER AS,
 1/0 IS BEING SHOWN?
 2) NOTE: PLEASE VERIFY MANY CIRCUITS
 SHOWN WITH #12 AND 15A BRKR.
 PLEASE CALL , IF THERE ARE ANY
 QUESTIONS, ON THIS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-01-24 Cont ID  
Sent By dpalmer Date 2005-01-24 Time 19:02 Rev Time 0.25
Received By dpalmer Date 2005-01-24 Time 19:02 Sent To M
Notes
2005-01-24 00:00:00ROUTED TO MECH DUE TO NEW SHEETS.
  
 ELECTRICAL OK, AND STAMPED.
 GENERATOR REMOVED FORM SCOPE OF WORK,
 MAY BE DONE UNDER SEPARATE PERMIT AT
 LATER DATE.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2004-12-23 Cont ID  
Sent By dpalmer Date 2004-12-23 Time 05:18 Rev Time 0.33
Received By dpalmer Date 2004-12-23 Time 05:11 Sent To P
Notes
2004-12-23 00:00:00*********** UNSAT ******************
  
 PLEASE SEE THE FOLLOWING NOTES, WHICH
 SOME ARE STILL FROM PREVIOUS REVIEW.
  
 1)NOTE: PLEASE SEE NOTES #'S 4,5 AND 7
 FROM PREVIOUS REVIEW. PLEASE ALSO SEE
 NOTE FOR LOAD CALCS.
  
 PLEASE SHOW GFI/GFI PROTECTION FOR ALL
 RECEPTS REQUIRED TO BE GFI PROTECTED
 UNDER 210.8.
  
 PLEASE SEE NOTE MANUFACTURE SPECS FOR
 GEN/TRANSFER SWITCH/ EM PANEL ETC.
 NOTE ON PLANS MENTIONS TO ALTER A UL
 LISTED PREWIRED PANEL?
  
 2)NOTE: PLEASE SEE MISSING EQUIPMENT
 GRNDS AFTER THE FIRST MEANS OF DISC.
 250.24,250.122
  
 ** PLEASE SEE GENERATOR LOCATION NEEDS
 TO BE SHOWN ON SITE/HOUSE PLANS.
  
 3)NOTE: PLEASE SEE AN ATTACHED COPY OF
 FS 553.80(2)(B) IS NOW ATTACHED. THIS
 IS
 GIVEN AS A NOTICE ONLY AT THIS TIME.
  
 4)NOTE: PLEASE SEE NOTE ON BOTTOM OF
 LOAD CALC MENTIONS EXISTING SERVICE ,
 YET RISER SHOWS NEW?
  
 5)NOTE: PLEASE SEE 220.31B FOR LOAD
 CALCS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-11-22 Cont ID  
Sent By dpalmer Date 2004-11-22 Time 14:39 Rev Time 0.50
Received By dpalmer Date 2004-11-22 Time 14:39 Sent To P
Notes
2004-11-22 00:00:00******* UNSAT ********
  
 1)NOTE: PLEASE SEE 210.52C1 FOR RECEPT
 SPACING ALONG KITCHEN COUNTERSPACE.
  
 2)NOTE: PLEASE SEE 424.3B FOR MIN OCP
 FOR AHU. PLEASE ALSO SEE 310.16 FOR
 SIZING OF CONDUCTORS.
  
 3)NOTE: PLEASE SEE 220.31B FOR LOAD
 CALCULATIONS.
  
 4)NOTE: PLEASE SEE FBC CHAPTER 34 FOR
 ADDITIONS TO EXSITNG DWELLINGS.
 PLEASE PROVIDE LAYOUT FOR NEW AND OR
 EXISTINGTO MEET 2002 NEC FOR GFI'S AND
 SD'S.
  
  
 5) NOTE: PLEASE SHOW ALL RECEPTS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED PER 210.8A-6
  
  
 6)NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ON EACH LEVEL OF A MULTI-LEVEL DWELLING
 UNIT.
 IN CLOSE PROXIMITY OF STAIRWAYS LEADING
 TO FLOORS ABOVE AND IN THE VICINITY OF
 BEDROOMS.
 PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE
 A MIN OF 3' FROM BATHROOM DOORS AND
 KITCHENS.
 ABOVE PER:FBC 905.2, NFPA-72 8-1.4
 THIS IS A COMMON TEXT NOTE AND PLANS MAY
 NOT NEED TO MEET ALL OF THE ABOVE.
  
 7)NOTE: PLEASE SUBMIT COMPLETE SPEC
 SHEETS ON NEW PROPOSED GENERATOR
 SYSTEM.
 PLEASE BE AWARE WE ARE CURRENTLY HAVING
 SOME ISSUES W/CERTAIN "MANUFACTURED"
 PRE-WIRED SYSTEMS THAT DO NOT MEET CODE
 COMPLIANCE.
  
 8)NOTE: PLEASE SEE 250.32 FOR GROUNDING
 ELECTRODE SYSTEM AT DETACHED BLDGS.
  
 9)NOTE: PLEASE PROVIDE ROOM DESIGNATION
 ON ELECTRICAL PLANS.
  
 PLEASE NOTE: UPON SUBMITTALS OF
 GENERATOR SPECS ETC, THERE MAY BE OTHER
 COMMENTS TO FOLLOW.
  
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2005-02-01 Cont ID  
Sent By alange Date 2005-02-01 Time 09:19 Rev Time 0.00
Received By alange Date 2005-01-29 Time 11:26 Sent To  
Notes
2005-01-29 00:00:00GAS PLAN REVIEW:
 SEPERATE PERMIT FOR GAS, BY LICENSED
 PLUMBING CONTRACTOR.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2004-10-25 Cont ID  
Sent By ptjomsto Date 2004-10-25 Time 16:11 Rev Time 0.00
Received By ptjomsto Date 2004-10-25 Time 16:11 Sent To  
Notes
2004-10-25 00:00:00HISTORIC APPROVED 10/25/04 BY S.PILAND

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2006-12-22 Cont ID  
Sent By adarroug Date 2006-12-22 Time 11:51 Rev Time 0.00
Received By adarroug Date 2006-12-22 Time 11:51 Sent To Z
Notes
2006-12-22 11:51:30TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-11-29 Cont ID  
Sent By spalmer Date 2006-11-29 Time 17:58 Rev Time 0.00
Received By spalmer Date 2006-11-29 Time 17:58 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-07-17 Cont ID  
Sent By adarroug Date 2006-07-17 Time 11:42 Rev Time 0.00
Received By adarroug Date 2006-07-17 Time 11:42 Sent To E
Notes
2006-07-17 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-07-03 Cont ID  
Sent By adarroug Date 2006-07-03 Time 15:49 Rev Time 0.00
Received By adarroug Date 2006-07-03 Time 15:49 Sent To E
Notes
2006-07-03 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-07-03 Cont ID  
Sent By adarroug Date 2006-07-03 Time 13:24 Rev Time 0.00
Received By adarroug Date 2006-07-03 Time 13:24 Sent To B
Notes
2006-07-03 00:00:00TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-06-25 Cont ID  
Sent By adarroug Date 2006-06-25 Time 16:21 Rev Time 0.00
Received By adarroug Date 2006-06-25 Time 16:21 Sent To Z
Notes
2006-06-25 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-01-24 Cont ID  
Sent By mjacobs Date 2005-01-24 Time 07:20 Rev Time 0.00
Received By mjacobs Date 2005-01-24 Time 07:20 Sent To E
Notes
2005-01-24 00:00:00TO "DP" DESK/RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-12-17 Cont ID  
Sent By mjacobs Date 2004-12-17 Time 07:56 Rev Time 0.00
Received By mjacobs Date 2004-12-17 Time 07:56 Sent To E
Notes
2004-12-17 00:00:00SENT TO "DP" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-11-09 Cont ID  
Sent By csiegber Date 2004-11-09 Time 09:57 Rev Time 0.00
Received By csiegber Date 2004-11-09 Time 09:57 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-10-25 Cont ID  
Sent By csiegber Date 2004-10-25 Time 16:50 Rev Time 0.00
Received By csiegber Date 2004-10-25 Time 16:50 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2005-09-09 Cont ID  
Sent By pkrauss Date 2005-09-09 Time 14:29 Rev Time 0.40
Received By pkrauss Date 2005-09-09 Time 14:24 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-01-26 Cont ID  
Sent By prafter Date 2005-01-26 Time 10:22 Rev Time 1.00
Received By prafter Date 2005-01-26 Time 10:22 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-01-03 Cont ID  
Sent By hmoser Date 2005-01-03 Time   Rev Time 0.00
Received By hmoser Date 2005-01-03 Time   Sent To B
Notes
2005-01-03 00:00:00PASS PRIVISO
 REFER TO FIGURE 304.3.2 YOU MUST HAVE
 VENTILATION IN CRAWL SPACE.PLAN REVIEW
 BY HAROLD MOSER (561)805-6732

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-11-29 Cont ID  
Sent By pkrauss Date 2004-11-29 Time 16:24 Rev Time 0.40
Received By pkrauss Date 2004-11-29 Time 16:13 Sent To B
Notes
2004-11-29 00:00:00DENIED:
 PROVIDE CALCULATIONS FOR COMBUSTION AIR
 FOR THE LAUNDRY ROOM PER 2001 FBC(M)
 CHAPTER 7.PLEASE INDICATE MAKE-UP AIR
 ON THE PLAN.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-01-29 Cont ID  
Sent By pschmitz Date 2005-01-29 Time 11:31 Rev Time 0.00
Received By pschmitz Date 2005-01-29 Time 11:31 Sent To B
Notes
2005-01-29 00:00:00PLUMBING PLAN REVIEW

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-12-29 Cont ID  
Sent By jleech Date 2004-12-29 Time 17:20 Rev Time 1.00
Received By jleech Date 2004-12-29 Time 17:20 Sent To M
Notes
2004-12-29 00:00:00GAS DENIED;
 TOTAL LOAD IS 425;000.PIPE TO BE SIZED
 AS MARKED IN RED.LOCATION OF GENERATOR
 NOT SHOWN.
 PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-11-23 Cont ID  
Sent By kstevens Date 2004-11-23 Time 05:25 Rev Time 0.50
Received By kstevens Date 2004-11-23 Time 05:25 Sent To M
Notes
2004-11-23 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
  
 1) SHT 12 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS. KITCHEN SINK
 IS NOT VENTED AND AS SHOWN IS AN "S"
 TRAP. SECTION 1002.3(5). AN AIR
 ADMITTENCE VALVE MAY BE USED UNDER THE
 COUNTER OF THE SINK PER SECTION 917, OR
 THE SINK MAY BE CONNECTED ON THE
 VERTICAL RISE OF THE VENT STACK AND
 ROUTED THROUGH THE WALL TO THE SINK.
 2) THE FOLLOWING INFORMATION IS REQUIRED
 FOR THE GAS PERMIT REQUIRED.
 A. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE BEING USED. -
 PLANS INDICATE "ALL UNDERGROUND PIPE
 WILL BE GALVANIZED" PLEASE INDICATE WHAT
 TYPE OF PIPING WILL BE USED FOR THE REST
 OF THE PIPING.
 3) PIPE SIZING NOT CORRECT PER TABLE
 402(2). SEE RED LINE CORRECTIONS MADE ON
 ONE SET OF PLANS FOR CORRECT PIPE SIZE
 REQUIRED.
 4) SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2001 FUEL
 GAS CODE SECTION 304. - (DRYER ROOM)
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 5 Status P Date 2006-12-27 Cont ID  
Sent By mmclean Date 2006-12-27 Time 18:05 Rev Time 0.00
Received By mmclean Date 2006-12-27 Time 18:05 Sent To  
Notes
2006-12-27 18:05:36REVISION - DRIVEWAY - UNSEALED PAVERS.

Review Stop Z ZONING
Rev No 4 Status F Date 2006-12-08 Cont ID  
Sent By mmclean Date 2006-12-08 Time 08:47 Rev Time 0.00
Received By mmclean Date 2006-12-08 Time 08:47 Sent To  
Notes
2006-12-08 08:54:48DENIED. - REVISION
 1. THE PROPOSED CONCRETE DRIVEWAY 16X25 WILL EXCEED THE
 ZONING GUIDELINES FOR MAINTIAN 75% OF LANDSCAPE WITHIN
 THE FIRST 25FT FRONT SETBACK.
  
 NOTE: MUST MAINTAIN 1000SQ FT OR 75% OF LANDSCAPE,
 WHICHEVER IS LESS WITHIN THE FIRST 25FT FRONT SETBACK.
  
 2. CAN ONLY PROPOSED A 12.5FT DRIVEWAY INCLUDING THE
 EXISITING WALKWAY.
  
 NOTE: MUST PULL A SEPARATE PERMIT FOR THE
 WALL/FOUNTAIN.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
  
  
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2006-06-29 Cont ID  
Sent By mmclean Date 2006-06-29 Time 16:46 Rev Time 0.00
Received By mmclean Date 2006-06-29 Time 16:46 Sent To I
Notes
2006-06-29 00:00:00REVISION - FOR GARDEN WALL & SLAB FOR
 SPA.

Review Stop Z ZONING
Rev No 2 Status P Date 2004-11-09 Cont ID  
Sent By mmclean Date 2004-11-09 Time 09:12 Rev Time 0.00
Received By mmclean Date 2004-11-09 Time 09:12 Sent To I
Notes
2004-11-09 00:00:00NOTE: ARCHITECT PROVIDED NEW SITE PLANS
 SHOWING SETBACKS.

Review Stop Z ZONING
Rev No 1 Status F Date 2004-11-08 Cont ID  
Sent By csiegber Date 2004-11-08 Time 16:50 Rev Time 0.00
Received By mmclean Date 2004-11-08 Time 17:12 Sent To I
Notes
2004-11-08 00:00:00NOTE: DENIED, NEED CLARITY ON SITEPLAN
 TO SCALE PROVIDING THE SETBACKS FOR THE
 ADDITION, SHED(SIDE/REAR)& DECK.NEED
 TO KNOW IF THE PAVED AREA IN REAR AND
 FOUNTAIN APART OF THIS PERMIT AND WHATS
 THE SETBACK FOR FOUNTAIN (REAR) AND FROM
 THE SHED.CALLED OWNER.