Plan Review Details - Permit 04101013
Plan Review Stops For Permit 04101013
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2006-10-17 Cont ID  
Sent By alange Date 2006-10-17 Time 11:21 Rev Time 0.00
Received By alange Date 2006-10-17 Time 11:21 Sent To  
Notes
2006-10-17 11:22:14COLUMN DELETION OK AND REVISED FLOOR PLAN OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2005-11-22 Cont ID  
Sent By alange Date 2005-11-22 Time 11:03 Rev Time 0.33
Received By alange Date 2005-11-22 Time 10:55 Sent To  
Notes
2005-11-22 00:00:00LEDGER REVISION OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-06-20 Cont ID  
Sent By alange Date 2005-06-20 Time 16:10 Rev Time 0.50
Received By alange Date 2005-06-20 Time 16:10 Sent To  
Notes
2005-06-20 00:00:00FRAMING REVISION LETTER RECIEVED OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-05-20 Cont ID  
Sent By alange Date 2005-05-20 Time 08:30 Rev Time 0.50
Received By alange Date 2005-05-20 Time 08:30 Sent To  
Notes
2005-05-20 00:00:00FOUNDATION STEM WALL REVISION OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-05-09 Cont ID  
Sent By mjacobs Date 2005-05-09 Time 14:19 Rev Time 2.00
Received By mjacobs Date 2005-05-09 Time 10:40 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-03-08 Cont ID  
Sent By alange Date 2005-03-08 Time 10:22 Rev Time 1.25
Received By alange Date 2005-03-08 Time 09:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-12-02 Cont ID  
Sent By alange Date 2004-12-02 Time 09:47 Rev Time 1.66
Received By alange Date 2004-12-02 Time 08:48 Sent To  
Notes
2004-12-02 00:00:00DENIED
  
 1.PLEASE COMPLETE ENERGY CALCS WITH
 PREPARERS SIGNATURE AND OWNER/AGENT
 SIGNATURE.
  
 2.SUBMIT 2 COPIES OF PRODUCT
 APPROVALS
 FOR OVER HEAD DOOR, STRAPS AND TIE
 DOWNS, ROOF TILE AND BITUMEN ROOF.
 ALL PRODUCT APPROVALS WITH QUALITY
 ASSURANCE ARE REQUIRED TO HAVE THE
 FOLLOWING SUBMITTED WITH THEM.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 PRODUCT APPROVAL FOR EXTERIOR DOOR IS
 NOT IMPACT RESITANT AS PER PLANS
 SPECIFICATIONS.
  
 3.SEC D-2 / A-7FBC 2111.1.9 WEST
 PALM BEACH AMMENDMENT TO THE FBC.
 WATER STOP TO BE 1/1/2" INCHES.
  
 4. SHOW ROOF AND WALL SHEATHING NAILING
 SCHEDULE ON PLANS.
  
 5.DETAIL D-11 / A-9 SHOW STRAPS AND
 TIE-DOWNS USED ON THIS DETAIL.
  
 6.SHOW METHOD OF CRAWL SPACE
 VENTILATION.
  
 7.FBC 1005.4.4EMERGENCY ESCAPE
 RESCUE OPENING SIZES. BEDROOM 2 WINDOWS
 SH-101 DOES NOT MEET REQUIRED OPENING
 OF
 5.7 SQ/FT IT IS ONLY 3.7 SQ/FT
  
 8.FBC 3401.7.1.2.1 SHOW HOW EXISTING
  
 BUILDING WILL COMPLY WIH THIS SECTION
 FOR SMOKE DETECTORS AND GFCI
 RECEPTICALS.
  
  
 9.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 8 Status N Date 2006-10-17 Cont ID  
Sent By dpalmer Date 2006-10-17 Time 07:18 Rev Time 0.00
Received By dpalmer Date 2006-10-17 Time 07:11 Sent To B
Notes
2006-10-17 07:19:47REV SENT BACK TO ELECWHICH WAS PASSED ON 10/1 AND
 STAMPED, SENT TO ART LANGE AND PLACED ON HIS TABLE.

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2006-10-01 Cont ID  
Sent By dpalmer Date 2006-10-01 Time 14:10 Rev Time 0.00
Received By dpalmer Date 2006-10-01 Time 13:58 Sent To M
Notes
2006-10-01 00:00:00PLANS OK,
  
  
 **REDLINED RISER TO VERIFY THE EXISTING
 GROUNDING ELECTRODE SHOWN. BASED ON THE
 4/0'S SHOWN FOR SEC'S, PLEASE SEE 250.66
 AS THE MIN SIZE FOR GEC IS #2. (#3 ) IS
 BEING SHOWN WHICH IS TOO SMALL.

Review Stop E ELECTRICAL
Rev No 6 Status F Date 2006-03-22 Cont ID  
Sent By dpalmer Date 2006-03-22 Time 07:51 Rev Time 0.00
Received By dpalmer Date 2006-03-22 Time 07:06 Sent To M
Notes
2006-03-22 00:00:00********* UNSAT **********
  
 *** PLEASE SEE CHANGES IN PLANS FROM
 PREVIOUS WHICH HAD CREATE SOME COMMENTS.
  
 1)NOTE: PLEASE SEE MISSING COUNTER SPACE
 GFI AS REQUIRED PER 210.52C1, THIS WAS
 ON PREVIOUS PLANS.'
  
 2) NOTE: PLEASE SEE MISSING ISLAND
 RECEPT PER 210.52C2
 ( ON PRE-PLANS)
  
 3)NOTE: PLEASE SEE PREVIOUS PLANS SHOWED
 "J-BOXES" FOR UC LIGHTING, HOWEVER THESE
 BOXES HAVE NOW BEEN REMOVED , YET THE
 CIRCUTIING FOR THESE ARE STILL BEING
 SHOWN.
  
 4)NOTE: PLEASE DEFINE DINING AREA ON
 PLANS, PLEASE SEE NEW RECEPTS NOW ADDED
 WHICH ARE ON LIGHTING CIRCUIT. PLEASE
 SEE 210.52B1 WHICH REQUIRES RECEPTS IN
 DINING RMS, BREALFAST AREAS AND THE LIKE
 TO BE ON ONE OR MORE OF THE SMALL
 APPLIANCE BRANCH CIRCUITS.
 PLEASE SEE TWO AREAS WHICH ARE LABLED
 "DEN", PLEASE SEE AREA ADJACENT TO THE
 KITCHEN WILL BE CONSIDERED THE DINING
 AREA.
 SHALL BE #12, 20
  
 5)NOTE: PLEASE CLARIFY RISER AS, PLANS
 ONLY ONE ONE METER/PANEL IN THE SAME
 LOCATION, HOWEVER PLEASE SEE RISER SHOWS
 THE METER/MAIN AND A SEPARATE PANEL WITH
 A MCB?? ARE THESE TWO PANEL?
 PLEASE ALSO SEE MIN CLEARENCE IS NOTED,
 HOWEVER IF CLEARENCE IS MET FOR
 METER/MAIN AND PANEL, THEN DISCONNECTING
 MEANS FOR CU IS NOT MET. PLEASE REVISE
 PLANS AND SHOW THE LAYOUT TO SCALE.
 PLEASE SEE NOTING THE TECHNICAL
 REQUIRMENT IS NOT ACCEPTABLE AS THERE
 SEEMS TO BE AN ISSUE WITH CLEARENCE IN
 THE FIELD.
 FBC 104.2.1, NEC 110.26
  
 6) NOTE: PLEASE SEE AN AHU WITH A
 DISCONNECT AND OCP IS NOW ADDED TO
 CLOSET WHICH IS NOT PERMITTED PER
 110.26,240.24
 PLEASE ALSO CORRELATE AS THIS DISC IS
 SHOWN AS 50A AND PANEL SEEMS TO INDICATE
 THE OCP AS 60A. PLEASE SEE 424.3VB WHICH
 REQUIRES A MIN OF 125% OCP.(THIS WOULD
 BE 60A MIN FOR 10KW).
  
 7) NOTE: PLEASE SEE PANEL SCHEDULE
 MENTIONS NEW PACKAGE UNIT A/C , HOWEVER
 PLEASE SEE ELECTRICAL PLANS DO NOT SHOW
 THIS?
 PLEASE SHOW AND SHOW DISC'S AS REQUIRED
 PER 440.11
  
 8)NOTE: PLEASE SEE MISSING RECEPT FOR 2'
 OR MORE OF WALL SPACE PER 210.52 IN
 BEDRM.
 THIS IS REDLINED ON PLANS.
  
 9) NOTE: PLEASE VERIFY NUMEROUS CIRCUITS
 ON PLANS WHICH SHOWS #12,HOWEVER
 INDICATES 15A OPC>?
 THIS IS ONLY A NOTE AS THIS DOES NOT
 VIOLATE CODE. PLEASE VERIFY,IF THIS IS
 SHOWN ON PLANS THIS WAY, THEN THIS IS
 WHAT IS REQUIRED TO BE INSTALLED.
  
 ** PLEASE VERIFY THE #3 AS EXISTING GEC,
 AS 250.66 REQUIRES A MIN OF #2.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 5 Status N Date 2005-05-02 Cont ID  
Sent By dpalmer Date 2005-05-02 Time 12:44 Rev Time 0.10
Received By dpalmer Date 2005-05-02 Time 12:44 Sent To M
Notes
2005-05-02 00:00:00NO ELECTRICAL REVISION SUBMITTED.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-04-07 Cont ID  
Sent By dpalmer Date 2005-04-07 Time 09:26 Rev Time 0.50
Received By dpalmer Date 2005-04-07 Time 09:26 Sent To P
Notes
2005-04-07 00:00:004X FEE REMOVED BY BLDG OFFICAL.
  
 STILL NEEDS NEW RECORDED NOC,
 ORIG NOC EXPIRED PER FS 713
 90 DAYS W/OUT WORK COMMENCING.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2005-03-28 Cont ID  
Sent By dpalmer Date 2005-03-28 Time 13:13 Rev Time 0.50
Received By dpalmer Date 2005-03-28 Time 13:10 Sent To P
Notes
2005-03-28 00:00:00******* UNSAT 3RD REVIEW ************
  
 PLEASE SEE NOTES FROM TWO PREVIOUS
 REVIEWS.
  
 1)NOTE: NOTE #1 OK
  
 2)NOTE: NOTE #2 NO, PLEASE SEE SECOND
 PART OF PF PREVIOUSE NOTE: 210.8,210.52E
  
 3)NOTE: NOTE #3, NO, PLEASE SEE PREVIOUS
 NOTES. 210.8A6
  
 4)NOTE: NOET #4, OK, NOTE ADDED TO
 PLANS.
  
 5)NOTE: NOTE #5, NO, PLEASE SEE FAC
 61G15-23.002 FOR REQUIRED CA# TO BE ON
 TITLE BLOCK. FS 471.023
 PLEASE SEE THIS IS REQUIRED FOR ALL
 SHEETS AND FOR ALL TRADES WHEATHER OR
 NOT COMMENT IS MADE BY OTHER
 REVIEWER(S).
 PLEASE ALSO SEE MECH/PLUMB SHEETS.
  
 6)NOTE: NOTE #6 OK.
  
 1)NOTE: NOTE #1, PLEASE SEE PLANS STILL
 MENTIONS "NEW PANEL A" IN TWO PLACES,
 HOWEVER RISER INDICATES EXISTING??
  
 2)NOTE: NOTE #2, PLEASE SEE A NOTICE WAS
 GIVEN ON PREVIOUS REVIEW WITH RESPECT TO
 DESIGN PROFESSIONAL AND REPEAT COMMENTS
 THREE OR MORE TIMES.
 PLEASE SEE A 4X FEE FOR PLAN REVIEW HAS
 NOW BEEN ACCESSED AND MUST BE PAID
 BEFORE PLANS ARE RE-SUBMITTED.
 FS 553.80(2)(B).
 PLEASE SEE ONE SET OF PLANS ARE BEING
 RETAINED FOR FILE FOR POSSIBLE REVIEW BY
 FBPE'S.
  
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 ONLY INSERT NEW REVISED SHEETS INTO TWO
 COMPLETE SETS FOR REVIEW AND STAMPING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-02-28 Cont ID  
Sent By dpalmer Date 2005-02-28 Time 06:47 Rev Time 0.30
Received By dpalmer Date 2005-02-28 Time 06:39 Sent To P
Notes
2005-02-28 00:00:00************* UNSAT ************
  
 PLEASE SEE SOME NOTES FROM PREVIOUS
 REVIEW STILL NEED TO BE ADDRESSED.
 PLEASE SEE NOTES BELOW TAKEN DIRECTLY
 INSERTED FROM PREVIOUS REVIEW.
  
 1)NOTE: OK.
  
  
 2)NOTE: PLEASE SEE FBC CHAPTER 34 FOR
 ADDITIONS AND REMODEL OF EXISTING
 DWELLINGS.
 PLEASE SHOW LAYOUT FOR ALL REQUIRED
 SD'S
 PER NFPA-72 8-1.4.1.6.2
 SMOKE DETECTORS ARE REQUIRED INSIDE AND
 OUTSIDE ALL SLEEPING ROOMS. ON EACH
 LEVEL OF A MULTI-LEVEL DWELLING UNIT.
 IN CLOSE PROXIMITY OF STAIRWAYS LEADING
 TO FLOORS ABOVE AND IN THE VICINITY OF
 BEDROOMS.
 PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE
 A MIN OF 3' FROM BATHROOM DOORS AND
 KITCHENS.
 ABOVE PER:FBC 905.2, NFPA-72 8-1.4.2
 **
 PLEASE ALSO SHOW LAYOUT FOR ALL RECEPTS,
 NEW OR EXISTING WHICH ARE REQUIRED TO BE
 GFI PROTECTED. 210.8
 PLEASE SEE FBC 3401.7.1.2.1 FOR
 ADDITIONS, AND 3401.7.2.6 FOR OVER 50%.
  
 3) NOTE: PLEASE SHOW ALL RECEPTS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED PER 210.8A-6
  
 4)NOTE: OK.PLEASE SEE CLEARENCE FOR
 110.26 FOR ELECTRICAL EQUIPMENT.
  
  
 5)NOTE: PLEASE HAVE ALL INFORMATION ON
 TITLE BLOCK BE CLEAR AND VISABLE.
 PLEASE SEE BELOEW FOR REQUIRED CA #.
 PLEASE SEE FAC 61G15-23.002, FS 471.023
 PLEASE ALSO SEE FS 471.025 WHICH
 REQUIRES LEGAL SIGNATURE FOR SIGNED AND
 SEALED PLANS. PLANS SEEM TO BE INITIALED
 WHICH ARE NOT ACCEPTABLE. IF PLANS ARE
 INDEED SIGNED WITH LEGAL SIGNATURE,
 PLEASE PROVIDE AND SIGNED,SEALED,
 NOTORIZED LETTER FOR LEGAL SIGNATURE.
 THIS WILL BE PLACED IN SIGNATURE FILE
 AND CAN BE USED FOR FUTURE REFERENCE.
  
 6)NOTE: PLEASE SHOW NEW FOOTER STEEL TO
 BE PART OF GROUNDING ELECTRODE SYSTEM.
 250.50
  
 *** NEW NOTES ***
  
 1)NOTE: PLEASE SEE PLANS MENTIONS NEW
 PANEL "A" AND EXISTING PANEL.?? PLEASE
 CLARIFY.
  
 2)NOTE: PLEASE SEE ATTACHED FS
 553.80(2)(B) WITH RESPECT TO DESIGN
 PROFESSIONALS, PLEASE SEE NOTICE ONLY
 GIVEN AT THIS TIME.
  
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 ONLY INSERT NEW REVISED SHEETS INTO
 COMPLETE SETS FOR REVIEW AND STAMPING.
  
 PLEASE SEE COMMENTS FROM OTHER REVIEWERS
 WHICH MAY HAVE AN AFFECT ON ELECTRICAL
 PLANS. (ZONING ETC).
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-11-12 Cont ID  
Sent By dpalmer Date 2004-11-12 Time 18:18 Rev Time 0.33
Received By dpalmer Date 2004-11-12 Time 18:18 Sent To P
Notes
2004-11-12 00:00:00************* UNSAT ************
  
 1)NOTE: PLEASE SEE ZONING COMMENTS,
 PLEASE CORRELATE PLANS WITH WORK
 PROPOSED.
 APPLICATION MENTIONS TO BUILD NEW 3-CAR
 GARAGE?
  
 2)NOTE: PLEASE SEE FBC CHAPTER 34 FOR
 ADDITIONS AND REMODEL OF EXISTING
 DWELLINGS.
 PLEASE SHOW LAYOUT FOR ALL REQUIRED
 SD'S
 PER NFPA-72 8-1.4.1.6.2
 SMOKE DETECTORS ARE REQUIRED INSIDE AND
 OUTSIDE ALL SLEEPING ROOMS. ON EACH
 LEVEL OF A MULTI-LEVEL DWELLING UNIT.
 IN CLOSE PROXIMITY OF STAIRWAYS LEADING
 TO FLOORS ABOVE AND IN THE VICINITY OF
 BEDROOMS.
 PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE
 A MIN OF 3' FROM BATHROOM DOORS AND
 KITCHENS.
 ABOVE PER:FBC 905.2, NFPA-72 8-1.4.2
 **
 PLEASE ALSO SHOW LAYOUT FOR ALL RECEPTS,
 NEW OR EXISTING WHICH ARE REQUIRED TO BE
 GFI PROTECTED. 210.8
 PLEASE SEE FBC 3401.7.1.2.1 FOR
 ADDITIONS, AND 3401.7.2.6 FOR OVER 50%.
  
 3) NOTE: PLEASE SHOW ALL RECEPTS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED PER 210.8A-6
  
 4)NOTE: PLEASE CLARIFY NUMBER OF A/C
 UNITS, PANEL SCHEDULE(S) SHOW 3-SYSTEMS
 1-EXISTING, TWO NEW , YET ONLY ONE COND
 UNIT FOR ONE OF THE NEW SYSTEMS??
  
 5)NOTE: PLEASE HAVE ALL INFORMATION ON
 TITLE BLOCK BE CLEAR AND VISABLE,
 PLEASE SEE CA# CAN NOT BE MADE OUT.
 FAC 61G15-23.002, FS 471.023
 PLEASE ALSO SEE FS 471.025 WHICH
 REQUIRES LEGAL SIGNATURE FOR SIGNED AND
 SEALED PLANS. PLANS SEEM TO BE INITIALED
 WHICH ARE NOT ACCEPTABLE. IF PLANS ARE
 INDEED SIGNED WITH LEGAL SIGNATURE,
 PLEASE PROVIDE AND SIGNED,SEALED,
 NOTORIZED LETTER FOR LEGAL SIGNATURE.
 THIS WILL BE PLACED IN SIGNATURE FILE
 AND CAN BE USED FOR FUTURE REFERENCE.
  
 6)NOTE: PLEASE SHOW NEW FOOTER STEEL TO
 BE PART OF GROUNDING ELECTRODE SYSTEM.
 250.50
  
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 ONLY INSERT NEW REVISED SHEETS INTO
 COMPLETE SETS FOR REVIEW AND STAMPING.
  
 PLEASE SEE COMMENTS FROM OTHER REVIEWERS
 WHICH MAY HAVE AN AFFECT ON ELECTRICAL
 PLANS. (ZONING ETC).
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2005-02-24 Cont ID  
Sent By adarroug Date 2005-02-24 Time 13:03 Rev Time 0.00
Received By adarroug Date 2005-02-24 Time 13:03 Sent To E
Notes
2005-02-24 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2006-09-25 Cont ID  
Sent By adarroug Date 2006-09-25 Time 14:43 Rev Time 0.00
Received By adarroug Date 2006-09-25 Time 14:43 Sent To E
Notes
2006-09-25 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2006-03-21 Cont ID  
Sent By dpalmer Date 2006-03-21 Time 15:54 Rev Time 0.00
Received By dpalmer Date 2006-03-21 Time 15:51 Sent To I
Notes
2006-03-21 00:00:00TO DP'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2006-03-17 Cont ID  
Sent By adarroug Date 2006-03-17 Time 16:27 Rev Time 0.00
Received By adarroug Date 2006-03-17 Time 16:27 Sent To P
Notes
2006-03-17 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2006-03-02 Cont ID  
Sent By adarroug Date 2006-03-02 Time 09:24 Rev Time 0.00
Received By adarroug Date 2006-03-02 Time 09:24 Sent To Z
Notes
2006-03-02 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2005-11-16 Cont ID  
Sent By adarroug Date 2005-11-16 Time 16:57 Rev Time 0.00
Received By adarroug Date 2005-11-16 Time 16:57 Sent To B
Notes
2005-11-16 00:00:00TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-06-08 Cont ID  
Sent By shill Date 2005-06-08 Time 08:31 Rev Time 0.00
Received By shill Date 2005-06-08 Time 08:31 Sent To B
Notes
2005-06-08 00:00:00TO AL DESK

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-05-18 Cont ID  
Sent By adarroug Date 2005-05-18 Time 11:13 Rev Time 0.00
Received By adarroug Date 2005-05-18 Time 11:13 Sent To B
Notes
2005-05-18 00:00:00TO "ALANGE" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-04-25 Cont ID  
Sent By adarroug Date 2005-04-25 Time 13:39 Rev Time 0.00
Received By adarroug Date 2005-04-25 Time 13:39 Sent To E
Notes
2005-04-25 00:00:00TO "DPALMER" DESK/REVISION
 NEW SHEETS

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-04-06 Cont ID  
Sent By adarroug Date 2005-04-06 Time 12:49 Rev Time 0.00
Received By adarroug Date 2005-04-06 Time 12:49 Sent To E
Notes
2005-04-06 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-03-24 Cont ID  
Sent By adarroug Date 2005-03-24 Time 14:04 Rev Time 0.00
Received By adarroug Date 2005-03-24 Time 14:04 Sent To E
Notes
2005-03-24 00:00:00TO "DPALMER'DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-02-17 Cont ID  
Sent By adarroug Date 2005-02-17 Time 10:23 Rev Time 0.00
Received By adarroug Date 2005-02-17 Time 10:23 Sent To Z
Notes
2005-02-17 00:00:00TO "Z" BOX/RESUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-11-10 Cont ID  
Sent By csiegber Date 2004-11-10 Time 13:54 Rev Time 0.00
Received By csiegber Date 2004-11-10 Time 13:54 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-10-25 Cont ID  
Sent By csiegber Date 2004-10-25 Time 16:12 Rev Time 0.00
Received By csiegber Date 2004-10-25 Time 16:12 Sent To Z
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 1 Status N Date 2005-04-12 Cont ID  
Sent By kstevens Date 2005-04-12 Time 10:35 Rev Time 0.00
Received By kstevens Date 2005-03-03 Time 13:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2006-10-02 Cont ID  
Sent By tgordon Date 2006-10-02 Time 09:35 Rev Time 0.30
Received By tgordon Date 2006-10-02 Time 09:35 Sent To P
Notes
2006-10-02 00:00:00*** PROVISO ***
 1) INSTANT HOT GAS WATER HEATER VENT
 TERMINATION MUST BE A MIN. OF 4 FT. FROM
 A/C CONDENSER UNIT, PER 2004 FBC/M 501.2
 .
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2006-03-22 Cont ID  
Sent By tgordon Date 2006-03-22 Time 09:20 Rev Time 1.15
Received By tgordon Date 2006-03-22 Time 09:20 Sent To P
Notes
2006-03-22 00:00:00*** DENIED ***
 1) MECHANICAL PLANS ARE SEALED BY AN
 ENGINEER AND REQUIRES THE ENGINEER'S
 INFORMATION PRINTED IN THE TITLE BLOCK,
 PER FAC 61G15.23.002 .
  
 2) PLEASE PROVIDE AN A/C EQUIPMENT LIST
 ON THE MECHANICAL PLAN SHOW ALL
 EQUIPMENT NEW AND EXISTING.
  
 3) PLEASE SHOW LOCATION OF CONDENSER
 UNITS ON MECHANICAL PLAN.
  
 4) PLEASE PROVIDE COMBUSTION AIR AND
 CALCULATIONS FOR GAS CLOTHES DRYER AND
 GAS INSTA-HOT WATER HEATER ON MECH.
 PLANS.
  
 5) REVISED MECHANICAL AND ELECTRICAL
 PLANS SUBMITTED, SECOND FLOOR PLAN DO
 NOT MATCH PLEASE CORRECT.
  
 6) ELECTRICAL PLANS ARE SHOWING 3 A/C
 SYSTEMS, MECH. PLANS ONLY TWO PLEASE
 CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2005-05-03 Cont ID  
Sent By prafter Date 2005-05-03 Time 10:32 Rev Time 0.50
Received By prafter Date 2005-05-03 Time 10:32 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-03-03 Cont ID  
Sent By prafter Date 2005-03-03 Time 13:52 Rev Time 0.50
Received By prafter Date 2005-03-03 Time 13:52 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2005-03-03 Cont ID  
Sent By prafter Date 2005-03-03 Time 12:36 Rev Time 1.50
Received By prafter Date 2005-03-03 Time 12:36 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-11-30 Cont ID  
Sent By pkrauss Date 2004-11-30 Time 06:42 Rev Time 0.55
Received By pkrauss Date 2004-11-29 Time 17:51 Sent To B
Notes
2004-11-30 00:00:00DENIED:
 1.PLAN SHEET M-1 INDICATES THE AHU IN
 THE LAUNDRY ROOM WITH THE GAS DRYER.
 PLEASE CLARIFY RETURN AIR DUCT
 LOCATION.
 PER 2001 FBC(M) 303.2, APPLIANCES SHALL
 NOT BE LOCATED IN HAZARDOUS AREAS
 UNLESS
 LISTED AND APPROVED FOR THE SPECIFIC
 INSTALLATION.PLEASE PROVIDE DETAIL OF
 THE DUCT SYSTEM FOR AHU #2.GAS
 CONTAMINANT SHALL NOT BE RE-CIRCULATED.
 SHOW COMPLIANCE WITH 2001 FBC(M) 303.3.
  
 2.PROVIDE MANUFACTURERS
 SUBMITTAL/INSTALLATION INSTURCTIONS FOR
 THE GAS DRYER.
  
 3.PER 2001 FBC(M)601.4 RETURN AIR IS
 TO BE EQUAL TO THE SUPPLY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 6 Status P Date 2006-10-14 Cont ID  
Sent By jleech Date 2006-10-14 Time 12:42 Rev Time 0.00
Received By jleech Date 2006-10-14 Time 12:42 Sent To E
Notes
2006-10-14 12:43:37AS BUILTS PLUMBING ONLY

Review Stop P PLUMBING
Rev No 5 Status F Date 2006-03-24 Cont ID  
Sent By mperson Date 2006-03-24 Time 10:53 Rev Time 1.25
Received By mperson Date 2006-03-24 Time 10:53 Sent To PC
Notes
2006-03-24 00:00:00****DENIED****
 REFERENCE: FBC-2004 PLUMBING
  
 PLEASE ADJUST YOUR DRAWINGS TO REFLECT
 THE FOLLOWING CHANGES REQUIRED FOR PLAN
 REVIEW:
  
 1. SHEET P-1 INDICATES A TANKLESS WATER
 INSTANT HOT HEATER, MODEL TKJM 140,000
 BTU. THE P&T FOR TANKLESS HEATER SHOWN
 IN WRONG LOCATION FOR NEW HEATER
 LOCATION. PLEASE ADJUST DRAWING.
 2. SUBMIT SHEET P-2 WITH NEW TANKLESS
 WATER HEATER ON WATER ISOMETRIC AND
 REMOVE EXISTING 60 GALLON GAS FIRED
 HEATER FROM ISOMETRIC.
 3. REMOVE GAS PIPE FROM SHEETS P-1 AND
 P-2, PLUMBING CONTRACTOR TO SUBMIT
 SEPERATE AS BUILTS UNDER GAS PERMIT.
 4. ADDED NEW CW SHOWER ON SHEET P-1
 NEEDS TO BE ADDED TO P-2 WATER
 ISOMETRICS, ALSO INDICATE WHAT THE ITEM
 IS NEXT TO SHOWER AND INDICATE THIS ITEM
 ON WATER ISOMETRIC.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop P PLUMBING
Rev No 4 Status P Date 2005-04-12 Cont ID  
Sent By kstevens Date 2005-04-12 Time 10:33 Rev Time 1.50
Received By kstevens Date 2005-04-12 Time 10:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2005-04-02 Cont ID  
Sent By kstevens Date 2005-04-02 Time 10:32 Rev Time 0.60
Received By kstevens Date 2005-04-02 Time 10:32 Sent To  
Notes
2005-04-02 00:00:00DENIED
 REFERENCE: FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 FROM PREVIOUS REVIEWS:
  
 ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-03-02 Cont ID  
Sent By kstevens Date 2005-03-02 Time 07:40 Rev Time 1.00
Received By kstevens Date 2005-03-02 Time 07:40 Sent To M
Notes
2005-03-02 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 A) FROM PREVIOUS REVIEW:
  
 2) SHT P-2 SANITARY RISER DIAGRAM, AT
 THE WASH MACHINE, THE CLEANOUT SHALL BE
 LOCATED 4 FEET ABOVE THE FLOOR FOR
 ACCESS OR SHALL LOOK OUT TO THE
 EXTERIOR OF THE WALL. SECTION 708.10
 4) SHT P-2 GAS ISOMETRIC SHOWS NEW
 LOCATION OF GAS METER, BUT UPSTREAM OF
 THE METER IS THE GAS GRILL (30K BTU).
 THIS APPLIANCE SHALL BE SHOWN
 DOWNSTREAM OF THE METER/REGULATOR.
 5) THE FOLLOWING INFORMATION IS
 REQUIRED FOR GAS PERMIT:
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2001
 FUEL GAS CODE. - ALL CUT SECTION LENGTHS
 ARE NOT SHOWN ON ISOMETRIC.
 B. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE IF BEING USED.
 C. TYPE OF GAS, (LP OR NATURAL)
 D. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2001 FUEL GAS CODE SECS. 401.8
 THRU 402.5.2 AND TABLES 402(1) THRU
 402(34). - INDICATE TABLE/TABLES USED. -
 TOTAL BTU LOAD IS NOT SHOWN AND THE
 TABLES USED ARE NOT SHOWN.
 E. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM
 PER FBC-2001 FUEL GAS CODE APPENDIX A -
 USE OF CAPACITY TABLES (A)(3).
 F. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2001 FUEL
 GAS CODE SECTION 304. - FOR DRYER ROOM
 G. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2001 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 H. CLEARLY SHOW THE LOCATION AND CAP-
 ACITY OF LP TANK(S), TYPE OF TANK (DOT
 OR ASME), THE DISTANCE OF THE TANK FROM
 THE BUILDING AND ADJACENT PROPERTY
 LINES THE DISTANCE OF THE TANK FROM ALL
 SOURCES OF IGNITION, OTHER CONTAINERS,
 BUILDINGS, AND THE LOCATION OF ANY
 BUILDING OPENINGS BELOW THE RELIEF VALVE
 OF THE TANK PER NFPA 58, TABLE 3-2.2.2.
 I. CLEARLY INDICATE ON THE PLAN IF THE
 LP TANK IS ABOVE OR BELOW GROUND, AND
 SHOW REQUIRED PROTECTION OF THE TANK
 AND APPURTENANCES PER NFPA 58. IF THE
 TANK IS BELOW GROUND THE CONTAINER SHALL
 BE SECURILY ANCHORED PER NFPA 58 SECTION
 3-2.2.7(H).
 6) ENGINEERS SHALL LEGIBLY INDICATE THE
 NAME, ADDRESS, AND LICENSE NUMBER ON
 EACH SHEET. IF PRACTICING THROUGH A
 DULY AUTHORIZED ENGINEERING BUSINESS THE
 ENGINEER SHALL AS WELL AS INDICATE THE
 NAME, ADDRESS, AND CERTIFICATE OF
 AUTHROIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. FAC
 61G15-23.002(2) & FS 471.025
 7) A PROFESSIONAL ENGINEER SHALL SIGN
 HIS NAME PER FAC 61G15-23.002(1) & FS
 471.025. PER FBPE INITIALS ARE NOT
 ACCEPTABLE. IF THIS IS YOUR LEGAL
 SIGNATURE, A SIGNED/SEALED/DATED
 NOTORIZED LETTER INDICATING YOUR LEGAL
 SIGNATURE IS REQUIRED FOR OUR FILES.
 8) PER ZONING NOTE THE GARAGE WILL NOT
 BE BUILT. PLEASE INDICATE WHERE THE
 WATER HEATER WILL BE LOCATED. INDICATE
 IF THE WATER HEATER WILL BE RATED FOR
 OUTSIDE USE OR IF IT WILL BE LOCATED
 INSIDE. SECTION 104.2.1
 *************NEW COMMENT***********
 1B) ONLY THE FIXTURES WITHIN THE
 BATHROOM GROUP SHALL CONNECT THE THE
 WET-VENTED HORIZONTAL BRANCH DRAIN. ANY
 ADDITIONAL FIXTURES SHALL DISCHARGE
 DOWNSTREAM OF THE WET VENT. THE W/M
 SHALL CONNECT DOWNSTREAM OF THE TOILET
 AND LAV OF THE POWDER ROOM .
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-11-23 Cont ID  
Sent By kstevens Date 2004-11-23 Time 06:02 Rev Time 1.00
Received By kstevens Date 2004-11-23 Time 06:02 Sent To M
Notes
2004-11-23 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) SHT P-2 SANITARY RISER DIAGRAM, AT
 THE WASH MACHINE, DOUBLE SANITARY TEE
 PATTERNS SHALL NOT RECEIVE THE
 DISCHARGE
 OF APPLIANCES WITH PUMPING ACTION
 DISCHARGE. SECTION 706.3. THE WASH
 MACHINE SHALL CONNECT BELOW THE LAUNDRY
 SINK.
 2) SHT P-2 SANITARY RISER DIAGRAM, AT
 THE WASH MACHINE, THE CLEANOUT SHALL BE
 LOCATED 4 FEET ABOVE THE FLOOR FOR
 ACCESS OR SHALL LOOK OUT TO THE
 EXTERIOR
 OF THE WALL. SECTION 708.10
 3) SHT P-2 WATER RISER DIAGRAM, AT THE
 WASH MACHINE, WATER HAMMER ARRESTORS
 ARE
 REQUIRED PER SECTION 604.9 AND SHALL BE
 LOCATED NEAR THE FIXTURE IN AN
 "EFFECTIVE RANGE" NOT IN THE CEILING.
 PDI-WH 201 AND MANUF. INSTALLATION
 INSTRUCTIONS.
 4) SHT P-2 GAS ISOMETRIC SHOWS NEW
 LOCATION OF GAS METER, BUT UPSTREAM OF
 THE METER IS THE GAS GRILL (30K BTU).
 THIS APPLIANCE SHALL BE SHOWN
 DOWNSTREAM
 OF THE METER/REGULATOR.
 5) THE FOLLOWING INFORMATION IS
 REQUIRED
 FOR GAS PERMIT.
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2001
 FUEL GAS CODE.
 B. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE BEING USED.
 C. TYPE OF GAS, (LP OR NATURAL)
 D. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2001 FUEL GAS CODE SECS. 401.8
 THRU 402.5.2 AND TABLES 402(1) THRU
 402(34). - INDICATE TABLE/TABLES USED
 E. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM
 PER
 FBC-2001 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES (A)(3).
 F. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2001 FUEL
 GAS CODE SECTION 304. - FOR DRYER ROOM
 G. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2001 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 H. CLEARLY SHOW THE LOCATION AND CAP-
 ACITY OF LP TANK(S), TYPE OF TANK (DOT
 OR ASME), THE DISTANCE OF THE TANK FROM
 THE BUILDING AND ADJACENT PROPERTY
 LINES
 THE DISTANCE OF THE TANK FROM ALL SOUR-
 CES OF IGNITION, OTHER CONTAINERS,
 BUILD
 INGS, AND THE LOCATION OF ANY BUILDING
 OPENINGS BELOW THE RELIEF VALVE OF THE
 TANK PER NFPA 58, TABLE 3-2.2.2.
 I. CLEARLY INDICATE ON THE PLAN IF THE
 LP TANK IS ABOVE OR BELOW GROUND, AND
 SHOW REQUIRED PROTECTION OF THE TANK
 AND
 APPURTENANCES PER NFPA 58. IF THE TANK
 IS BELOW GROUND THE CONTAINER SHALL BE
 SECURILY ANCHORED PER NFPA 58 SECTION
 3-2.2.7(H).
 6) ENGINEERS SHALL LEGIBLY INDICATE THE
 NAME, ADDRESS, AND LICENSE NUMBER ON
 EACH SHEET. IF PRACTICING THROUGH A
 DULY
 AUTHORIZED ENGINEERING BUSINESS THE
 ENGINEER SHALL AS WELL AS INDICATE THE
 NAME, ADDRESS, AND CERTIFICATE OF
 AUTHROIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. FAC
 61G15-23.002(2) & FS 471.025
 7) A PROFESSIONAL ENGINEER SHALL SIGN
 HIS NAME PER FAC 61G15-23.002(1) & FS
 471.025. PER FBPE INITIALS ARE NOT
 ACCEPTABLE. IF THIS IS YOUR LEGAL
 SIGNATURE, A SIGNED/SEALED/DATED
 NOTORIZED LETTER INDICATING YOUR LEGAL
 SIGNATURE IS REQUIRED FOR OUR FILES.
 8) PER ZONING NOTE THE GARAGE WILL NOT
 BE BUILT. PLEASE INDICATE WHERE THE
 WATER HEATER WILL BE LOCATED. INDICATE
 IF THE WATER HEATER WILL BE RATED FOR
 OUTSIDE USE OR IF IT WILL BE LOCATED
 INSIDE. SECTION 104.2.1
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 3 Status F Date 2006-03-17 Cont ID  
Sent By mmclean Date 2006-03-17 Time 07:36 Rev Time 0.00
Received By mmclean Date 2006-03-17 Time 07:36 Sent To I
Notes
2006-03-17 00:00:00DENIED,
 1. NEED TO SHOW (INDICATE) THE CHANGE IN
 REVISION ON PLANS THAT AFFECTS THE
 ZONING REVIEW.
 2. PLEASE SHOW CHANGES ON SURVEY (2
 COPIES) AND FLOOR PLAN.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 2 Status P Date 2005-02-23 Cont ID  
Sent By mmclean Date 2005-02-23 Time 12:22 Rev Time 0.00
Received By mmclean Date 2005-02-23 Time 12:22 Sent To I
Notes
2005-02-23 00:00:00NOTE:1. MUST PULL A SEPARATE PERMIT FOR
 FOR NEW CIRCULAR DRIVEWAY. MUST PROVIDE
 TWO NEW SURVEY WITH DIMENSION OF
 CIRCULAR DRIVEWAY.
 2. MUST PULL SEPARATE PERMIT FOR GATE
 WITH CITY OF WPB UTILITY DEPT EASEMENT
 APPROVAL.
 CALLED BOBBY REGARDING THE NOTES.
  
 MICHELLE MCLEAN
 ZONING TECHNINCIAN
 CONSTRUCTION SERVICES
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2004-11-09 Cont ID  
Sent By csiegber Date 2004-11-09 Time 16:12 Rev Time 0.00
Received By mmclean Date 2004-11-09 Time 17:22 Sent To I
Notes
2004-11-09 00:00:00NOTE: OWNER DECIDED NOT TO DO THE 2
 CAR
 GARAGE AND CIRCULAR DRIVEWAY.
 CONTRACTOR WILL PROVIDE 2 NEW COPY OF
 SIGN SEAL SITEPLAN.