| Plan Review Stops For Permit 04100753 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-20 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-06-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-06-09 |
Time |
14:26 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2005-06-09 |
Time |
14:26 |
Sent To |
PC |
|
| Notes |
| 2005-06-09 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- OWNER AGREED TO APPLY FOR SEPARATE | | | PERMIT FOR BUTT GLAZING ASSEMBLY AT NOOK | | | AREA. | | | | | | 2- MODEL OF DOORS FOR GARAGE AND BATH #3 | | | SHOWN ON DADE COUNTY NOA DON'T MATCH | | | MODELS SHOWN ON FLORIDA PRODUCT APPROVAL | | | REPORT. SUBMIT DRAWINGS THAT MATCH THOSE | | | IN THE FLORIDA PRODUCT APPROVAL OR APPLY | | | FOR LOCAL PRODUCT APPROVAL. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-05-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-05-12 |
Time |
10:33 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2005-05-12 |
Time |
10:33 |
Sent To |
PC |
|
| Notes |
| 2005-05-12 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- DRAWINGS STILL DON'T SHOW PALM BEACH | | | COUNTY IMPACT FEES STAMP AND PAID | | | RECEIPT STILL SHOWS $3.00 BALANCE. | | | | | | 2- DADE COUNTY NOA ALONE IS NOT | | | AUTOMATICALLY A FLORIDA STATE WIDE | | | PRODUCT APPROVAL. PROVIDE FLORIDA | | | PRODUCT APPROVAL OR APPLY FOR LOCAL | | | PRODUCT APPROVAL AS REQUIRED BY RULE | | | 9B-72 OF THE FLORIDA BUILDING COMMISSION | | | FOR: | | | A) FRENCH DOOR WITH SIDELITES ASSEMBLY | | | AT FAMILY ROOM. | | | | | | B) SOLID SWING DOOR AT GARAGE AND BATH | | | #3 SIDE DOOR. | | | | | | C) ENTRY & MASTER BEDROOM DOORS. | | | | | | D) USP TRUSS CONNECTORS SPECIFIED ON | | | PLANS. | | | | | | 3- BAY WINDOW AT NOOK AREA WAS CHANGED | | | FOR BUTT GLAZING SYSTEM. NEED TO PROVIDE | | | FLORIDA PRODUCT APPROVAL OR APPLY FOR | | | LOCAL PRODUCT APPROVAL. | | | IF APPLYING FOR LOCAL PRODUCT APPROVAL | | | ENGINEER TO READ SEC. 2406.2 FBC 2001 | | | AND PROVIDE ALL REQUIRED INFORMATION. | | | ALSO, SEE WWW.FLORIDABUILDING.ORG FOR | | | LOCAL PRODUCT APPROVAL REQUIREMENTS AS | | | REQUIRED BY RULE 9B-72. | | | | | | 4- NOTICE OF COMMENCEMENT EXPIRES AFTER | | | 90 DAYS. NEED RE-RECORDED NOTICE OF | | | COMMENCEMNT. | | | | | | 5- ENGINEER TO PROVIDE COMPLETE | | | SPECIFICATIONS FOR BEAM #12. IS MISSING | | | STIRRUPS REINFORCEMENT. SEC. 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-02-28 |
Time |
16:13 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-02-28 |
Time |
16:13 |
Sent To |
PC |
|
| Notes |
| 2005-02-28 00:00:00 | CHECKLIST: | | | 1- DRAWINGS NEED PALM BEACH COUNTY | | | IMPACT FEES STAMP. ALSO, PAID RECEIPT | | | SAYS THERE IS $3.00 BALANCE DUE. CLARIFY | | | AND BRING BACK STAMPED DRAWINGS AND PAID | | | IN FULL RECEIPT. | | | | | | 2-A) ENTRY PORCH ON SHEET 6/10 CALLS FOR | | | CONCRETE BEAMS, WHILE, ROOF FRAMING PLAN | | | AND PORCH DETAILS CALL FOR WOOD BEAMS. | | | REVISE AS REQUIRED. | | | | | | B) ENTRY PORCH IN ROOF FRAMING PLAN | | | SHOWS 3-2X12 BEAM WHILE PORCH DETAIL ON | | | SHEET 8/10 SHOWS 2-2X12 BEAM. REVISE AS | | | REQUIRED. | | | | | | 3- SPECIFY HOW IS CANTILEVERED BEAM AT | | | NOOK AREA ANCHORED TO THE SIDE COLUMNS. | | | SPECIFY REINFORCING. SEC. 104.2.1.2 OF | | | CITY AMENDMENTS TO FBC 2001. | | | | | | 4- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: | | | A) ENTRY DOORS WITH DRAWINGS THAT MATCH | | | FLORIDA PRODUCT APPROVAL INFORMATION. | | | DRAWINGS SUBMITTED ARE FOR "BENCHMARK". | | | NEED DRAWINGS FOR "THERMA-TRU" MODELS AS | | | SPECIFIED ON FLORIDA PRODUCT APPROVAL | | | #1170 SUBMITTED. | | | | | | B) DOOR WITH SIDELITES AS SHOWN ON PLANS | | | | | | C) 45 DEGREES FIXED WINDOW COMPLETE | | | SYSTEMAS SHOWN ON NOOK AREA. | | | | | | D) GARAGE SIDE DOOR. | | | | | | 5- STORM SHUTTERS: A) CLEARLY MARK ON | | | DRAWINGS SPECIFIC MOUNTING CONDITIONS | | | AND ANCHOR TYPE AND SPACING TO BE USED. | | | CLEARLY MARK INSTALLATION SCHEDULE | | | INSIDE ENGINEERED DRAWINGS TO VERIFY | | | ANCHOR TYPE AND SPACING USED. | | | **NOTE; SEE PLANS FOR ENGINEER'S | | | CALCULATED DESIGN PRESSURES AT OPENINGS. | | | VERIFY STRUCTURE TO BE ATTACHED TO: 3000 | | | PSI CONCRETE OR MASONRY. | | | SEC. 104.2.1.2 CITY AMENDMETNS TO FBC. | | | B) CLEARLY INDICATE TYPE OF SHUTTERS | | | USED. 22 OR 24 GAUGE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-11-29 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-11-29 |
Time |
17:53 |
Sent To |
PC |
|
| Notes |
| 2004-11-29 00:00:00 | CHECKLIST: | | | 1-PAY IMPACT FEES TO PALM BEACH COUNTY. | | | BRING BACKSTAMPED DRAWINGS AND PAID | | | RECEIPT. | | | | | | 2-NEED RECORDED NOTICE OF COMMENCEMENT. | | | | | | 3-RIGHT ELEVATION DON'T MATCH PLANS. | | | THERE IS AN ADDITIONAL WINDOW SHOWN ON | | | THE ELEVATION. REVISE AS REQUIRED. | | | | | | 4-SPECIFY CONCRETE SLAB JOINTS OR | | | SPECIFY WWM SUPPORTS & SPACING AS REQ'D | | | BY SEC. 1909.3 FBC 2001. | | | | | | 5-LINTEL SHEDULE DON'T MATCH SIZES. SEE | | | FOUNDATION PLANS AND LINTEL SCHEDULE | | | AND | | | REVISE AS REQUIRED. | | | | | | 6-SPECIFY BEAM AT NOOK AREA. SECTION | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | 7-TYPICAL WALL SECTION: A) SPECIFY | | | FIREBLOCKING AS REQUIRED BY SECTION | | | 705.3.1.1 FBC 2001. | | | B) INDICATE MIN. FOOTING EMBEDMENT AS | | | REQUIRED BY SEC. 1804.1.3 FBC 2001. | | | | | | 8-REVISE PORCH DETAIL TO MATCH PORCH | | | CONSTRUCTION SHOWN ON PLANS. PORCH | | | SHOWN | | | IS FOR WOOD FRAMED STRUCTURE. | | | | | | 9-SOIL TEST REPORT. REVISE SQUARE FOOT | | | OF PROPOSED STRUCTURE. SEE PLANS. | | | | | | 10-PROVIDE 2X STRUCTURAL BUCK DETAIL | | | FOR | | | SWING DOORS AS REQUIRED ON THE PRODUCT | | | APPROVAL. | | | | | | 11-PROVIDE FLORIDA/LOCAL PRODUCT | | | APPROVAL FOR: | | | A) ENTRY DOORS WITH DRAWINGS THAT MATCH | | | THOSE SUBMITTED FOR FLORIDA BUILDING | | | COMMISION REVIEW AND APPROVAL. | | | B) DOOR W/ SIDELITES AS SHOWN ON PLANS. | | | C) 45 DEGREES FIXED WINDOW SYSTEM. | | | D) GARAGE SIDE DOOR. | | | | | | 12-PROVIDE COMPLETE INFORMATION FOR | | | STORM SHUTTERS INCLUDING:A) KEY PLAN | | | AND | | | COMPLETE INSTALLATION SCHEDULE (SEE | | | ATTACHED SAMPLE) | | | B)INDICATE ON DWGS SPECIFIC MOUNTING | | | CONDITIONS AND ANCHOR TYPE AND SPACING | | | TO BE USED ACCORDING TO THE DESIGN | | | PRESSURES, EDGE DISTANCE, CONNECTION | | | TYPE, PANEL SPAN AND STRUCTURE TO BE | | | ATTACHED TO (MASONRY OR CONCRETE). | | | | | | 13-SHEET 1/10: UPDATE INFORMATION. SEE | | | COMMENTS ON PLANS. | | | | | | 14-SPECIFY SIZE OF WINDOW TO BE | | | INSTALLED AT NOOK AREA. SECTION | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | 15-UPDATE TRUSS ANCHOR SCHEDULE. SEE | | | LATEST CATALOGUE. OR, PROVIDE COMPLETE | | | ENGINEERING FOR TYPE AND NUMBER OF | | | FASTENERS THAT DIFFER FROM APPROVED AND | | | PUBLISHED ON MANUFATURER'S CATALOGUE. | | | SEE COMMENTS ON PLANS. | | | **CLARIFY WHY ARE THERE ADDITIONAL | | | FASTENERS SHOWN ON RIGHT HAND SIDE | | | COLUMN? | | | | | | 16-WHICH ARE THE CONNECTORS A3 AND A4. | | | THEY ARE NOT SHOWN ON TRUSS ANCHOR | | | SCHEDULE. | | | | | | 17-ROOF FRAMING PLAN AND PORCH DETAIL | | | TO | | | MATCH. THEY SPECIFY DIFFERENT NUMBER OF | | | 2X12'S. REVISE AS REQUIRED. SEE | | | COMMENTS | | | ON PLAN. | | | | | | 18-OWES $203.82 FOR UPDATED VALUATION | | | AND RADON FEES. | | | | | | 19-OWNER/AGENT TO SIGN AND DATE ENERGY | | | CALCULATIONS AS REQUIRED BY SEC. 103.1.2 | | | CHAPTER 13 FBC 2001. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-08-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-06 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-06 |
Time |
12:19 |
Sent To |
PC |
|
| Notes |
| 2006-08-06 00:00:00 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE PLANS SHALL CONTAIN | | | THE PRINTED NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR PLANS AND DESIGN. | | | PLEASE SEE PLANS SHOUDL STATE: DRAWN BY: | | | AND SO ON. | | | FBC 106.1.2 2004 | | | FBC 104.2.1 2001 | | | | | | 2) NOTE: PLEASE SEE WHIRLPOOL/JACUZZI | | | TUB SHALL INDICATE THE REQUIRED GFI | | | PROTECTION PER 680.71 EITHER BY BRKR OR | | | DEVICE. | | | | | | 3) NOTE: PLEASE SEE KITCHEN COUNTER | | | SPACE AS A RECEPT IS BEING SHOWN W/OUT | | | SYMBOL FOR GFI PROTECTION. | | | 210.8A6 | | | | | | 4) NOTE: PLEASE SEE DISHWASHER DISPOSAL | | | IS BEING SHOWN WITH TWO SEPARATE | | | DEVICE/RECEPTS ON PLANS , YET FED BY A | | | 2-POLE BRKR. | | | 210.4 | | | | | | 5) NOTE: PLEASE STATE THE 2002 | | | NFPA-70(NEC) ON PLANS | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-04-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-25 |
Time |
19:57 |
Rev Time |
0.40 |
| Received By |
dpalmer |
Date |
2005-04-25 |
Time |
19:50 |
Sent To |
P |
|
| Notes |
| 2005-04-25 00:00:00 | **REDLINED ** | | | | | | MISSING TWO RECEPTS PER 210.52, | | | REDLINED, NO NEED TO REVISE OR CORRECT | | | PLANS. | | | STAMPED ELECTRICAL PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-02-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-15 |
Time |
06:58 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-02-15 |
Time |
06:46 |
Sent To |
P |
|
| Notes |
| 2005-02-15 00:00:00 | ******** UNSAT 2ND REVIEW ********* | | | | | | PLEASE SEE SOME NOTES FROM FIRST REVIEW | | | STILL NEED TO BE ADDRESSED. | | | | | | 1)NOTE: NOTE #1, OK, TITLE BLOCK FOR | | | JOHN AVERCAMP REMOVED. | | | | | | 2)NOTE: NOTE #2 NO. | | | SUBMIT AIC RATING S FOR MAINS/ SERVICE | | | PER 110.9/215.5 | | | | | | 3)NOTE: NOTE #3 OK. | | | NOTED ON PLANS. | | | | | | 4)NOTE: NOTE #4 NO, PLEASE SEE BOTH | | | BATHS AND GEN LTS FOR BATHS ARE SHOWN ON | | | SAME CIRCUIT. | | | PLEASE SEE 210.52D,210.11C3 | | | | | | 5)NOTE: NOTE #5, OK. | | | MOVED SD'S. | | | | | | 6)NOTE: NOTE #6 NO, PLEASE SEE | | | IRRIGATION PUMP STILL SHOWS 30A OCP ON | | | #12 AWG. | | | PLEASE SEE OTHER ITEMS WERE REVISED. | | | | | | 7)NOTE: NOTE #7 #8 AND #9 OK. | | | | | | 8)NOTE: NOTE#10 NO. NOTE ADDED FOR ARC | | | FAULT PROTECTION, HOWEVER PLEASE SEE | | | NOTE # 6 ON ELECTRICAL NOTES. | | | | | | 11)NOTE: NOTE #11, YES/NO, PLEASE SEE | | | DISC WERE ADDED HOWEVER, MANUFACTURE | | | SPECS NOT SUBMITTED. | | | PLEASE SUBMIT SPECS SHOWING LISTING FROM | | | A NRTL. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS FOR | | | REVIEW AND STAMPING. | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-12 |
Time |
09:06 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-11-12 |
Time |
09:06 |
Sent To |
M |
|
| Notes |
| 2004-11-12 00:00:00 | ******** UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE PLANS CONTAINING | | | TITLE BLOCKS, ARE REQUIRED TO BE SIGNED, | | | DATED AND SEALED BY PERSON RESPONSIBLE | | | FOR PLANS. | | | FS 481.221, 471.025 | | | PLEASE ALSO SEE FAC 61G15-23.002, | | | 61G1-16.004 FOR MISSING LICENSE #'S AS | | | REQUIRED UNDER FS 481.219 AND 471.023 | | | FOR FIRMS ETC. | | | THIS IS REQUIRED ON ALL SHEETS WHEATHER | | | OR NOT COMMENT IS MADE BY OTHER | | | REVIEWERS. | | | FBC 104.2.1 | | | | | | | | | 2) NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | | | | 3)NOTE: PLEASE SHOW ALL RECEPTS | | | SERVING KITCHEN COUNTERSPACE AS GFI/GFI | | | PROTECTED PER 210.8A-6 | | | | | | | | | 4) NOTE: PLEASE LIST ALL THE REQ'D | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3 | | | | | | 5)NOTE: PLEASE SEE NFPA -72 8-1.4.2 FOR | | | LOCATIONS OF SD'S. A MIN OF 3' FROM BATH | | | DRS. | | | | | | 6)NOTE: PLEASE CORRELATE LOADS/OCP AND | | | AWG ON PANEL SCHEDULE. | | | PLEASE SEE INSTA-HOTS UNITS, SHOWS | | | 2P30A | | | WITH 11.8KW LOAD? | | | PLEASE ALSO SEE LOADS SHOWN FOR COND | | | UNIST AS 10KW, THIS SHOULD BE FOR AHU'S | | | HOWEVER THESE ARE NOT LISTED. | | | PLEASE ALSO SEE 424.3B FOR OCP ETC. | | | 310.16, 240.4 | | | | | | 7)NOTE: PLEASE SEE 210.52E FOR MISSING | | | FRONT AND REAR RECEPTS. | | | | | | 8)NOTE: PLEASE SEE 210.8 FOR ALL RECEPTS | | | TO BE GFI/ GFI PROTECTED. | | | | | | 9)NOTE: PLEASE SEE 250.6,250.24, AN | | | EQUIPMENT GRND IS NOT INSTALLEDFROM | | | METER TO FIRST MEANS OF DISC. | | | | | | 10)NOTE: PLEASE SEE 2002 NEC 210.12, | | | PLEASE LIST ARC FAULT PROETCTION ON | | | PANEL SCHEDULE. | | | NOTES MENTIONS SD' TO BE WIRED INTO | | | KITCHEN/BATH LTS? THIS WOULD REQUIRED | | | THESE TO ALSO BE ARC FAULT PROTECTED. | | | | | | 11)NOTE: PLEASE SHOW DISCONNECTING MEANS | | | FOR INSTA-HOT UNITS. IF OCP, THEN THESE | | | MUST MEET 110.26. | | | PLEASE ALSO SEE MANUFACTS SPECS FOR | | | CLEARENCE REQ',MENTS FOR UNITS. | | | | | | PLEASE SEE ONE SET OF ELECTRICAL PLANS | | | HAVE BEEN REDLINED FOR MOST OF THE ABOVE | | | ITEMS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD MAY BE SUBMITTED FOR | | | REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | NOTES MENTIONS SD'S TO BE WIRED TO | | | | | | 7 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-08-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-02 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-02 |
Time |
10:13 |
Sent To |
E |
|
| Notes |
| 2006-08-02 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-08 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-06-08 |
Time |
14:53 |
Sent To |
B |
|
| Notes |
| 2005-06-08 00:00:00 | TO 'JG' DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-04-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-25 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-25 |
Time |
10:11 |
Sent To |
E |
|
| Notes |
| 2005-04-25 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-09 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-09 |
Time |
14:43 |
Sent To |
E |
|
| Notes |
| 2005-02-09 00:00:00 | TO DPALMER DESK/RESUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-11-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-29 |
Time |
17:56 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-10-20 |
Time |
13:55 |
Sent To |
PC |
|
| Notes |
| 2004-11-08 00:00:00 | TO SFD RACK/E | | 2004-10-25 00:00:00 | TO Z | | 2004-10-20 00:00:00 | TO JH BOX/ADDRESSING |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-11-18 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2004-11-18 |
Time |
07:42 |
Rev Time |
0.45 |
| Received By |
drunnels |
Date |
2004-11-18 |
Time |
07:41 |
Sent To |
P |
|
| Notes |
| 2004-11-18 00:00:00 | PAT RAFTER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-05-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-05-06 |
Time |
13:25 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-05-06 |
Time |
13:25 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-02-23 |
Time |
11:00 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2005-02-23 |
Time |
11:00 |
Sent To |
B1 |
|
| Notes |
| 2005-02-23 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | FROM PREVIOUS REVIEW: | | | 1) KITCHEN SINK IS NOT VENTED. SECTION | | | 901.2.1. - IF THIS IS AN AIR ADMITTENCE | | | VALVE, THEN SHOW IT AS SUCH ON THE RISER | | | DIAGRAM. | | | 2) WASH MACHINE REQUIRES A STANDPIPE, | | | AND THE CLEANOUT SHALL BE INSTALLED 4' | | | ABOVE THE FLOOR FOR ACCESS. SECTIONS | | | 1002.1 AND 708.10 | | | 3) ANY PORTION OF THE DRAINAGE SYSTEM | | | INSTALLED UNDERGROUND, SHALL NOT BE LESS | | | THAN 2" IN DIAMETER. SECTION 710.3 | | | | | | 2) SEE SHEET 3/10 FOR RED LINE | | | CORRECTIONS TO BE MADE TO THE SANT. | | | RISER DIAGRAM. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-12 |
Time |
08:20 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-11-12 |
Time |
08:20 |
Sent To |
E |
|
| Notes |
| 2004-11-12 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHT 5 SANITARY RISER DIAGRAM DOES NOT | | | MEET THE CODE REQUIREMENTS, NOR DOES IF | | | RELEECT THE FLOOR PLAN. SECTION | | | 104.2.1. | | | A) KITCHEN SINK IS NOT VENTED. SECTION | | | 902.1. | | | B) WASH MACHINE IS NOT VENTED, REQUIRES | | | A STADPIPE, AND THE CLEANOUT SHALL BE | | | INSTALLED 4 FT. ABOVE THE FLOOR FOR | | | ACCESS. SECTIONS 902.1, 1002.1, & | | | 708.10 | | | C) MASTER BATH SHOWS 2 SHOWERE ON THE | | | SANT. RISER DIAGRAM, BUT ONLY ONE ON THE | | | FLOOR PLAN. PLEASE CLARIFY. SECTION | | | 104.2.1. | | | D) BATH #2 IS SHOWN AS CONNECTING TO | | | THE BLDG DRAIN DOWNSTREAM OF THE | | | KITCHEN, WASH MACHINE, AND MASTER BATH | | | ON THE RISER DIATRAM, BUT UPSTREAM OF | | | THESE FIXTURES ON THE FLOOR PLAN. PLEASE | | | SHOW THE RISER AS IT WILL BE INSTALLED. | | | SECTION 104.2.1. | | | | | | 2) SEE ATTACHED SHEET SHOWING AN EXAMPLE | | | OF A SANITARY RISER DIAGRAM THAT MEETS | | | THE CODE REQUIREMENTS AND REFLECT THE | | | FLOOR PLAN. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-11-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-11-06 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-11-06 |
Time |
11:23 |
Sent To |
I |
|
| Notes |
| 2004-11-06 00:00:00 | NOTE: DRIVEWAY MUST MEET ZONING | | | GUIDELINES OF 1000SQ FT OR 75% WHICHEVER | | | IS LESS IN THE FIRST 25FT FRONT SETBACK. |
|
|