| Plan Review Stops For Permit 04100328 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-24 |
Time |
13:09 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2006-03-24 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2006-03-24 00:00:00 | REVISION FOR STAIRS AND INSULATION OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-12-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-12-02 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-12-02 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2005-12-02 00:00:00 | CHANGED ROOF PRODUCT - PRODUCT APPROVAL | | | FILED WITH ROOF PERMIT 05120096 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-01-03 |
Time |
13:45 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2005-01-03 |
Time |
13:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-12-17 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-12-17 |
Time |
10:06 |
Rev Time |
1.33 |
| Received By |
alange |
Date |
2004-12-17 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2004-12-17 00:00:00 | | | | | | | BUILDING REVIEW OK, NEED THE FOLLOWING | | | BEFORE A PERMIT CAN BE ISSUED. | | | | | | | | | BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-11-08 |
Time |
16:06 |
Rev Time |
2.75 |
| Received By |
alange |
Date |
2004-11-08 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2004-11-08 00:00:00 | DENIED | | | | | | 1.PLEASE SIGN OWNER/AGENT ON ENERGY | | | CALCS. | | | | | | 2.PRODUCT APPROVALS FOR PGT WINDOWS | | | MISSING SECOND COPY. | | | SUBMIT 2 COPIES OF PRODUCT APPROVALS | | | FOR | | | STRAPS AND TIEDOWNS. | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 3.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | | | | 4. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 5.FBC 1007.8.4 ALTERNATING STAIRS | | | SHALL COMPLY WITH THIS SECTION. | | | DISTANCE BETWEEN HANDRAILS SHALL BE | | | A MIN. OF 17" AND A MAX. OF 24" SHOW ON | | | PLANS. | | | | | | 6.S-1 SHOW METHOD OF TIE-IN FROM | | | EXISTING SLAB TO NEW SLAB. | | | | | | 7.A-7 SHOW HEIGHT OF FINISH FLOOR ABOVE | | | GRADE. | | | | | | 8.SHOW ON PLANS EXISTING SQUARE | | | FOOTAGE AND NEW SQUARE FOOTAGE UNDER | | | A/C. | | | | | | 9.FBC3401.7.1.2.1 SHOW HOW COMPLIANCE | | | WILL BE MADE WITH SMOKE DETECTORS AND | | | GFCI OUTLETS IN EXISTING BUILDING. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | SEE NOTES FROM PLUMBING REVIEW | | | REGARDING | | | ARCHITECTS LICENSE THAT COULD DELAY | | | ISSUING OF BUILDING PERMIT. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-02-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-02-17 |
Time |
15:12 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2006-02-17 |
Time |
15:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-01-20 |
Time |
22:18 |
Rev Time |
1.00 |
| Received By |
jleahy |
Date |
2006-01-20 |
Time |
22:17 |
Sent To |
|
|
| Notes |
| 2006-01-20 00:00:00 | THESE DRAWINGS ARE NOT THE ELECTRICAL | | | PAGES. | | | | | | SUBMIT ELECTRICAL CHANGES ON THE | | | ELECTRICAL PAGES OF THESE PLANS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-01-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-01-10 |
Time |
14:06 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-01-10 |
Time |
12:39 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-12-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-12-08 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2004-12-08 |
Time |
17:09 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-10-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-25 |
Time |
14:33 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-10-26 |
Time |
13:00 |
Sent To |
M |
|
| Notes |
| 2004-10-28 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE PROVIDE A CALCULATION | | | INCLUDING ALL ADDED LOADS IMPOSED,ALL | | | EXISTING LOADS AND THE EXISTING OR | | | PROPOSED SERVICE SPECIFICATIONS PER | | | 215.15. | | | | | | 2} NOTE THAT A SMALL APPLIANCE CIRCUIT | | | REQUIRED BY 210.11(C)(1) IS MISSING | | | FROM THE PANEL SCHEDULE. | | | | | | 3} VERIFY THAT THE SYSTEM VOLTAGE IS | | | 208 AS THAT IS NOT COMMON VOLTAGE FOR A | | | RESIDENTIAL AREA. | | | | | | 4} THE DRYER CIRCUIT IS LISTED AS | | | 1-POLE 20 AMP, PLEASE VERIFY. | | | | | | 5} CIRCUIT #26 ON THE PANEL SCHEDULE IS | | | LISTED AS GENERAL CONVENIENCE. THIS | | | CIRCUIT MUST COMPLY WITH 210.52(B) AND | | | BE A SMALL APPLIANCE CIRCUIT. | | | | | | 6} RECEPTACLE SPACING MUST COMPLY WITH | | | 210.52, SEE WALLS IN THE DINING ROOM | | | ANDNEW WALLS IN THE LIVING ROOM. | | | | | | 7} THE GUEST BATH REQUIRES ANOTHER | | | RECEPTACLE TO COMPLY WITH THE 3' | | | REQUIREMENT OF 210.52(D). | | | | | | 8} SMOKE DETECTORS MUST BE INSTALLED TO | | | COMPLY WITH 905.2.2 FBC., AND 8-1.4.1.6. | | | 2 NFPA-72. ALSO SEE 210.12. | | | | | | 9} THE ENGINEERS TITLE BLOCK MUST | | | CONTAIN A CERTIFICATE OF AUTHORIZATION | | | NUMBER PER 61G15-23.002. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2006-03-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-08 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-08 |
Time |
11:12 |
Sent To |
B |
|
| Notes |
| 2006-03-08 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-22 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-22 |
Time |
16:21 |
Sent To |
M |
|
| Notes |
| 2006-02-22 00:00:00 | TO "TGORDON" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-08 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-08 |
Time |
15:28 |
Sent To |
E |
|
| Notes |
| 2006-02-08 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-08 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-08 |
Time |
15:19 |
Sent To |
M |
|
| Notes |
| 2006-02-08 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-01-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-18 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-18 |
Time |
13:54 |
Sent To |
M |
|
| Notes |
| 2006-01-18 00:00:00 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-01-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-17 |
Time |
17:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-17 |
Time |
17:54 |
Sent To |
E |
|
| Notes |
| 2006-01-17 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-01-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-09 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-09 |
Time |
16:26 |
Sent To |
E |
|
| Notes |
| 2006-01-09 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-11-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-28 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-28 |
Time |
10:45 |
Sent To |
Z |
|
| Notes |
| 2005-11-28 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
P |
Date |
2004-12-22 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-22 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-22 |
Time |
09:30 |
Sent To |
P |
|
| Notes |
| 2004-12-22 00:00:00 | SENT TO "P" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-12-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-06 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-06 |
Time |
07:57 |
Sent To |
E |
|
| Notes |
| 2004-12-06 00:00:00 | SENT TO "BT" DESK/RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-23 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-23 |
Time |
11:01 |
Sent To |
Z |
|
| Notes |
| 2004-11-23 00:00:00 | SENT TO "Z" TO MMCLEAN DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-10-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-25 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-25 |
Time |
14:32 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-10-12 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-10-21 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-12 |
Time |
14:22 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-02-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-02-23 |
Time |
08:14 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-02-23 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2006-02-23 00:00:00 | REV. TO MECH. PLANS AND E-CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-02-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-02-09 |
Time |
11:21 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2006-02-09 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2006-02-09 00:00:00 | *** DENIED *** | | | 1) PLANS SUBMITTED ARE DIFFICULT TO READ | | | AND I AM UNABLE TO TELL WHERE AND WHAT | | | ROOMS ARE OR WHERE DOORS ARE LOCATED. | | | CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY. PER 2001 FBC 106.1.1 | | | . | | | | | | 2) REVISION PLANS ARE COPYS SHOWING JACK | | | GREEN'S INFORMATION ON THEM. IF ABBY | | | SUCKLE IS GOING TO SEAL THEM THEN HER | | | TITLE BLOCK MUST BE ON THEM. SEE FLORIDA | | | ADMINISTRATIVE CODES 61G1-16.003 USE OF | | | SEAL, AND 61G-16.004 TITLE BLOCK (COPY | | | ATTACHED). | | | | | | 3) NEED TO SUBMIT 2 COPYS OF ALL | | | PAPER-WORK (ENERGY CAL'S.). | | | | | | 4) PLEASE RESUBMIT ABBY SUCKLE'S LETTER | | | WHEN YOU RESUBMIT YOUR PLANS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-01-23 |
Time |
09:50 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2006-01-23 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2006-01-23 00:00:00 | *** DENIED *** | | | 1)ORIGINAL MECHANICAL PLANS AND ENERGY | | | CALCULATIONS ON FILE ARE BY AN ENGINEER | | | (JACK GREEN) SO HE MUST MAKE ALL | | | REVISIONS. | | | | | | 2) PLEASE NOTE THE PAPER WORK SUBMITTED | | | WAS A REVISION NOT A SUBMITTAL. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-10-28 |
Time |
17:04 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-11-05 |
Time |
06:42 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-06-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-13 |
Time |
11:24 |
Rev Time |
1.26 |
| Received By |
kstevens |
Date |
2005-05-28 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2005-06-13 00:00:00 | REVISION OK - CHANGED FROM ARCHITECT TO | | | ENGINEER FOR PLUMBING. LETTER OK - SANT. | | | RISER DIAGRAM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-30 |
Time |
16:55 |
Rev Time |
0.88 |
| Received By |
kstevens |
Date |
2004-12-30 |
Time |
15:29 |
Sent To |
B1 |
|
| Notes |
| 2004-12-30 00:00:00 | PROVISO - SEPARATE GAS PERMIT REQUIRED. | | | REVISIONS FOR GAS PLANS REQUIRED. SHOW: | | | 1) TYPE OF GAS | | | 2) DEVELOPED LENGHT | | | 3) ALL PIPE SIZES | | | 4) CLARIFY BUT INPUT FOR WATER HEATER. | | | (SEE SHT P2 - 208(A) | | | KSTEVENS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-12-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-15 |
Time |
06:25 |
Rev Time |
1.15 |
| Received By |
kstevens |
Date |
2004-12-15 |
Time |
06:25 |
Sent To |
B1 |
|
| Notes |
| 2004-12-15 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHTS P1 AND P3 FLOOR PLAN AND SANT. | | | RISER DIAGRAM DO NOT MEET CODE. FROM | | | PREVIOUS REVIEW, EVERY DRY VENT SHALL | | | RISE VERTICALLY TO A MINIMUM OF 6 INCHES | | | ABOVE THE FLOOD LEVEL RIM OF THE HIGHEST | | | TRAP OR TRAPPED FIXTURE BEING VENTED. | | | SECTION 905.4. - STILL SHOWN ON THE | | | FLOOR PLAN AND THE RISER DIAGRAM ARE | | | HORIZONTAL DRY VENTS BELOW THE FLOOD | | | LEVEL RIM OF THE W/C'S, TUBS, SHOWERS. | | | THE PLANS SHALL REFLECT THE INSTALLATION | | | OF THE PLUMBING. PLEASE SUBMIT A | | | PLUMBING FLOOR PLAN AND SANT. RISER | | | DIAGRAM THAT MEET THE CODE REQUIREMENT. | | | SECTION 104.2.1. | | | 2) RESPONSE TO COMMENT #2 STATES "THERE | | | IS CURRENTLY NO GAS SERVICE TO THE | | | HOUSE". COMMENT 2D STATES "GAS LOAD | | | EXISTING=130,000 BTU" PLEASE CLARIFY. | | | SHOW EXISTING GAS CONNECTION TO THE | | | PIPING OFF THE METER. PLEASE CLARIFY | | | SECTION 104.2.1. | | | 3) BY NOT SHOWING THE DISTANCE FROM THE | | | METER TO THE JACUZZI, WHEN THAT PIPE IS | | | ADDED TO THE SYSTEM, THE PIPING FROM THE | | | METER WILL HAVE TO BE CHANGED TO ACCOUNT | | | FOR THE TOTAL DEVELOPED LENGTH OF THE | | | SYSTEM. IF THIS IS SHOWN ON THE RISER | | | DIAGRAM THE PIPE CAN BE SIZED FOR FUTURE | | | APPLIANCES WHEN INSTALLED AT THIS TIME. | | | TABLE 402(2). | | | 4) SUBMIT TWO SETS OF PLANS FOR REVIEW. | | | REMOVE ALL VOIDED SHEETS AND RESUBMIT | | | ONE SET FOR COMPAIRISON. SECTION | | | 104.2.1 | | | | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-05 |
Time |
08:17 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2004-11-05 |
Time |
08:17 |
Sent To |
B1 |
|
| Notes |
| 2004-11-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) SHT P3 SANITARY RISER DIAGRAM, EVERY | | | DRY VENT SHALL RISE VERTICALLY TO A | | | MINIMUM OF 6 INCHES ABOVE THE FLOOD | | | LEVEL RIM OF THE HIGHEST TRAP OR TRAPPED | | | FIXTURE BEING VENTED. SECTION 905.4 | | | 2) THE FOLLOWING INFORMATION IS REQUIRED | | | FOR THE GAS PERMIT: | | | A) SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS. | | | B) SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF THE CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING | | | USED) | | | C) TYPE OF GAS, (NATURAL OR LP) | | | D) BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2001 FUEL GAS SECS. 401.8 THRU | | | 402.5.2 AND TABLES 402(1) THRU 402(34) | | | E) SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY< (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | THE FBC-2001 FUEL GAS APPENDIX A-USE OF | | | CAPACITY TABLES(A)(3) | | | F) SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR PER THE FBC-2001 FUEL GAS CODE SEC. | | | 304 | | | G) INDICATE THE DELIVERY PRESSURE(PSI) | | | PER FBC-2001 FUEL GAS SEC 402.2. IF | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI | | | 3) PME SHEETS: THE DATE THAT THE | | | SIGNATURE AND SEAL IS AFFIXED SHALL BE | | | ENTERED ON PLANS. FAC 61G15-23.002(1) | | | IF PRACTICING THROUGH A DULY AUTHORIZED | | | ENGINEERING BUSINESS, ENGINEERS SHALL | | | LEGIBLY INDICATE THEIR NAME, AND LICENSE | | | NUMBER, AS WELL AS, THE NAME, ADDRESS | | | AND CERTIFICATE OF AUTHORIZATION NUMBER | | | OF THE ENGINEERING BUSINESS ON EACH | | | SHEET. 61G15-23.002(2) FS 471.025 | | | 4) RECORDS FROM DBPR STATE OF FLORIDA | | | INDICATES THAT THELICENSE OF JACK A. | | | GREEN IS DELINQUENT AT THIS TIME. THIS | | | SHALL BE ACTIVATED PRIOR TO APPROVAL OF | | | THE PLANS. (SEE ATTACHED SHEET) | | | 5) ARCHITECTURAL SHEETS: THE PERSONAL | | | SEAL, SIGNATURE AND DATE OF THE | | | ARCHITECT SHALL APPEAR ON ALL | | | ARCHITECTURAL DOCUMENTS TO BE FILED FOR | | | PUBLIC RECORD. 61G1-16.003 AND LICENSE | | | NUMBER SHALL APPEAR ON EACH SHEET. FS | | | 481.219 | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2005-12-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-12-08 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-12-08 |
Time |
17:24 |
Sent To |
I |
|
| Notes |
| 2005-12-08 00:00:00 | APPROVING REVISION OF WALL.4FT HIGH | | | STONE WALL SUPPORTING FOUNTAIN. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-12-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-12-03 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-12-03 |
Time |
16:31 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-10-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-12 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-10-21 |
Time |
15:04 |
Sent To |
I |
|
| Notes |
| 2004-10-21 00:00:00 | DENIED, NEED TO PROVIDE TWO SURVEY | | | SHOWING THE ADDITION WITH SETBACKS. | | | TWO FLOOR PLANS SHOWING THE ADDITION. | | | CALLED CONTR MM |
|
|