Plan Review Details - Permit 04100328
Plan Review Stops For Permit 04100328
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2006-03-24 Cont ID  
Sent By alange Date 2006-03-24 Time 13:09 Rev Time 0.66
Received By alange Date 2006-03-24 Time 13:09 Sent To  
Notes
2006-03-24 00:00:00REVISION FOR STAIRS AND INSULATION OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-12-02 Cont ID  
Sent By shill Date 2005-12-02 Time 11:33 Rev Time 0.00
Received By shill Date 2005-12-02 Time 11:33 Sent To  
Notes
2005-12-02 00:00:00CHANGED ROOF PRODUCT - PRODUCT APPROVAL
 FILED WITH ROOF PERMIT 05120096

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-01-03 Cont ID  
Sent By alange Date 2005-01-03 Time 13:45 Rev Time 1.25
Received By alange Date 2005-01-03 Time 13:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-12-17 Cont ID  
Sent By alange Date 2004-12-17 Time 10:06 Rev Time 1.33
Received By alange Date 2004-12-17 Time 10:06 Sent To  
Notes
2004-12-17 00:00:00 
  
 BUILDING REVIEW OK, NEED THE FOLLOWING
 BEFORE A PERMIT CAN BE ISSUED.
  
  
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-11-08 Cont ID  
Sent By alange Date 2004-11-08 Time 16:06 Rev Time 2.75
Received By alange Date 2004-11-08 Time 16:06 Sent To  
Notes
2004-11-08 00:00:00DENIED
  
 1.PLEASE SIGN OWNER/AGENT ON ENERGY
 CALCS.
  
 2.PRODUCT APPROVALS FOR PGT WINDOWS
 MISSING SECOND COPY.
 SUBMIT 2 COPIES OF PRODUCT APPROVALS
 FOR
 STRAPS AND TIEDOWNS.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 3.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
  
 4. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 5.FBC 1007.8.4 ALTERNATING STAIRS
 SHALL COMPLY WITH THIS SECTION.
 DISTANCE BETWEEN HANDRAILS SHALL BE
 A MIN. OF 17" AND A MAX. OF 24" SHOW ON
 PLANS.
  
 6.S-1 SHOW METHOD OF TIE-IN FROM
 EXISTING SLAB TO NEW SLAB.
  
 7.A-7 SHOW HEIGHT OF FINISH FLOOR ABOVE
 GRADE.
  
 8.SHOW ON PLANS EXISTING SQUARE
 FOOTAGE AND NEW SQUARE FOOTAGE UNDER
 A/C.
  
 9.FBC3401.7.1.2.1 SHOW HOW COMPLIANCE
 WILL BE MADE WITH SMOKE DETECTORS AND
 GFCI OUTLETS IN EXISTING BUILDING.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 SEE NOTES FROM PLUMBING REVIEW
 REGARDING
 ARCHITECTS LICENSE THAT COULD DELAY
 ISSUING OF BUILDING PERMIT.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-02-17 Cont ID  
Sent By jleahy Date 2006-02-17 Time 15:12 Rev Time 0.30
Received By jleahy Date 2006-02-17 Time 15:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2006-01-20 Cont ID  
Sent By jleahy Date 2006-01-20 Time 22:18 Rev Time 1.00
Received By jleahy Date 2006-01-20 Time 22:17 Sent To  
Notes
2006-01-20 00:00:00THESE DRAWINGS ARE NOT THE ELECTRICAL
 PAGES.
  
 SUBMIT ELECTRICAL CHANGES ON THE
 ELECTRICAL PAGES OF THESE PLANS.
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-01-10 Cont ID  
Sent By btrobaug Date 2006-01-10 Time 14:06 Rev Time 1.00
Received By btrobaug Date 2006-01-10 Time 12:39 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-12-08 Cont ID  
Sent By btrobaug Date 2004-12-08 Time 14:15 Rev Time 0.00
Received By btrobaug Date 2004-12-08 Time 17:09 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-10-28 Cont ID  
Sent By csiegber Date 2004-10-25 Time 14:33 Rev Time 0.75
Received By btrobaug Date 2004-10-26 Time 13:00 Sent To M
Notes
2004-10-28 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE PROVIDE A CALCULATION
 INCLUDING ALL ADDED LOADS IMPOSED,ALL
 EXISTING LOADS AND THE EXISTING OR
 PROPOSED SERVICE SPECIFICATIONS PER
 215.15.
  
 2} NOTE THAT A SMALL APPLIANCE CIRCUIT
 REQUIRED BY 210.11(C)(1) IS MISSING
 FROM THE PANEL SCHEDULE.
  
 3} VERIFY THAT THE SYSTEM VOLTAGE IS
 208 AS THAT IS NOT COMMON VOLTAGE FOR A
 RESIDENTIAL AREA.
  
 4} THE DRYER CIRCUIT IS LISTED AS
 1-POLE 20 AMP, PLEASE VERIFY.
  
 5} CIRCUIT #26 ON THE PANEL SCHEDULE IS
 LISTED AS GENERAL CONVENIENCE. THIS
 CIRCUIT MUST COMPLY WITH 210.52(B) AND
 BE A SMALL APPLIANCE CIRCUIT.
  
 6} RECEPTACLE SPACING MUST COMPLY WITH
 210.52, SEE WALLS IN THE DINING ROOM
 ANDNEW WALLS IN THE LIVING ROOM.
  
 7} THE GUEST BATH REQUIRES ANOTHER
 RECEPTACLE TO COMPLY WITH THE 3'
 REQUIREMENT OF 210.52(D).
  
 8} SMOKE DETECTORS MUST BE INSTALLED TO
 COMPLY WITH 905.2.2 FBC., AND 8-1.4.1.6.
 2 NFPA-72. ALSO SEE 210.12.
  
 9} THE ENGINEERS TITLE BLOCK MUST
 CONTAIN A CERTIFICATE OF AUTHORIZATION
 NUMBER PER 61G15-23.002.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2006-03-08 Cont ID  
Sent By adarroug Date 2006-03-08 Time 11:12 Rev Time 0.00
Received By adarroug Date 2006-03-08 Time 11:12 Sent To B
Notes
2006-03-08 00:00:00TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2006-02-22 Cont ID  
Sent By adarroug Date 2006-02-22 Time 16:21 Rev Time 0.00
Received By adarroug Date 2006-02-22 Time 16:21 Sent To M
Notes
2006-02-22 00:00:00TO "TGORDON" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2006-02-08 Cont ID  
Sent By adarroug Date 2006-02-08 Time 15:29 Rev Time 0.00
Received By adarroug Date 2006-02-08 Time 15:28 Sent To E
Notes
2006-02-08 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2006-02-08 Cont ID  
Sent By adarroug Date 2006-02-08 Time 15:19 Rev Time 0.00
Received By adarroug Date 2006-02-08 Time 15:19 Sent To M
Notes
2006-02-08 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-01-18 Cont ID  
Sent By adarroug Date 2006-01-18 Time 13:54 Rev Time 0.00
Received By adarroug Date 2006-01-18 Time 13:54 Sent To M
Notes
2006-01-18 00:00:00TO "M" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-01-17 Cont ID  
Sent By adarroug Date 2006-01-17 Time 17:54 Rev Time 0.00
Received By adarroug Date 2006-01-17 Time 17:54 Sent To E
Notes
2006-01-17 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-01-09 Cont ID  
Sent By adarroug Date 2006-01-09 Time 16:26 Rev Time 0.00
Received By adarroug Date 2006-01-09 Time 16:26 Sent To E
Notes
2006-01-09 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-11-28 Cont ID  
Sent By adarroug Date 2005-11-28 Time 10:45 Rev Time 0.00
Received By adarroug Date 2005-11-28 Time 10:45 Sent To Z
Notes
2005-11-28 00:00:00TO "Z" BOX

Review Stop I INCOMING/PROCESSING
Rev No 5 Status P Date 2004-12-22 Cont ID  
Sent By mjacobs Date 2004-12-22 Time 09:30 Rev Time 0.00
Received By mjacobs Date 2004-12-22 Time 09:30 Sent To P
Notes
2004-12-22 00:00:00SENT TO "P" BOX.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-12-06 Cont ID  
Sent By mjacobs Date 2004-12-06 Time 07:57 Rev Time 0.00
Received By mjacobs Date 2004-12-06 Time 07:57 Sent To E
Notes
2004-12-06 00:00:00SENT TO "BT" DESK/RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-11-23 Cont ID  
Sent By mjacobs Date 2004-11-23 Time 11:01 Rev Time 0.00
Received By mjacobs Date 2004-11-23 Time 11:01 Sent To Z
Notes
2004-11-23 00:00:00SENT TO "Z" TO MMCLEAN DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-10-25 Cont ID  
Sent By csiegber Date 2004-10-25 Time 14:32 Rev Time 0.00
Received By csiegber Date 2004-10-25 Time 14:32 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-10-12 Cont ID  
Sent By mmclean Date 2004-10-21 Time 15:04 Rev Time 0.00
Received By csiegber Date 2004-10-12 Time 14:22 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2006-02-23 Cont ID  
Sent By tgordon Date 2006-02-23 Time 08:14 Rev Time 0.30
Received By tgordon Date 2006-02-23 Time 08:14 Sent To  
Notes
2006-02-23 00:00:00REV. TO MECH. PLANS AND E-CAL'S.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2006-02-09 Cont ID  
Sent By tgordon Date 2006-02-09 Time 11:21 Rev Time 1.30
Received By tgordon Date 2006-02-09 Time 11:21 Sent To  
Notes
2006-02-09 00:00:00*** DENIED ***
 1) PLANS SUBMITTED ARE DIFFICULT TO READ
 AND I AM UNABLE TO TELL WHERE AND WHAT
 ROOMS ARE OR WHERE DOORS ARE LOCATED.
 CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY. PER 2001 FBC 106.1.1
 .
  
 2) REVISION PLANS ARE COPYS SHOWING JACK
 GREEN'S INFORMATION ON THEM. IF ABBY
 SUCKLE IS GOING TO SEAL THEM THEN HER
 TITLE BLOCK MUST BE ON THEM. SEE FLORIDA
 ADMINISTRATIVE CODES 61G1-16.003 USE OF
 SEAL, AND 61G-16.004 TITLE BLOCK (COPY
 ATTACHED).
  
 3) NEED TO SUBMIT 2 COPYS OF ALL
 PAPER-WORK (ENERGY CAL'S.).
  
 4) PLEASE RESUBMIT ABBY SUCKLE'S LETTER
 WHEN YOU RESUBMIT YOUR PLANS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-01-23 Cont ID  
Sent By tgordon Date 2006-01-23 Time 09:50 Rev Time 0.35
Received By tgordon Date 2006-01-23 Time 09:49 Sent To  
Notes
2006-01-23 00:00:00*** DENIED ***
 1)ORIGINAL MECHANICAL PLANS AND ENERGY
 CALCULATIONS ON FILE ARE BY AN ENGINEER
 (JACK GREEN) SO HE MUST MAKE ALL
 REVISIONS.
  
 2) PLEASE NOTE THE PAPER WORK SUBMITTED
 WAS A REVISION NOT A SUBMITTAL.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-11-05 Cont ID  
Sent By btrobaug Date 2004-10-28 Time 17:04 Rev Time 0.35
Received By pkrauss Date 2004-11-05 Time 06:42 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2005-06-13 Cont ID  
Sent By kstevens Date 2005-06-13 Time 11:24 Rev Time 1.26
Received By kstevens Date 2005-05-28 Time 11:55 Sent To  
Notes
2005-06-13 00:00:00REVISION OK - CHANGED FROM ARCHITECT TO
 ENGINEER FOR PLUMBING. LETTER OK - SANT.
 RISER DIAGRAM

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-12-30 Cont ID  
Sent By kstevens Date 2004-12-30 Time 16:55 Rev Time 0.88
Received By kstevens Date 2004-12-30 Time 15:29 Sent To B1
Notes
2004-12-30 00:00:00PROVISO - SEPARATE GAS PERMIT REQUIRED.
 REVISIONS FOR GAS PLANS REQUIRED. SHOW:
 1) TYPE OF GAS
 2) DEVELOPED LENGHT
 3) ALL PIPE SIZES
 4) CLARIFY BUT INPUT FOR WATER HEATER.
 (SEE SHT P2 - 208(A)
 KSTEVENS

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-12-15 Cont ID  
Sent By kstevens Date 2004-12-15 Time 06:25 Rev Time 1.15
Received By kstevens Date 2004-12-15 Time 06:25 Sent To B1
Notes
2004-12-15 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 1
  
 1) SHTS P1 AND P3 FLOOR PLAN AND SANT.
 RISER DIAGRAM DO NOT MEET CODE. FROM
 PREVIOUS REVIEW, EVERY DRY VENT SHALL
 RISE VERTICALLY TO A MINIMUM OF 6 INCHES
 ABOVE THE FLOOD LEVEL RIM OF THE HIGHEST
 TRAP OR TRAPPED FIXTURE BEING VENTED.
 SECTION 905.4. - STILL SHOWN ON THE
 FLOOR PLAN AND THE RISER DIAGRAM ARE
 HORIZONTAL DRY VENTS BELOW THE FLOOD
 LEVEL RIM OF THE W/C'S, TUBS, SHOWERS.
 THE PLANS SHALL REFLECT THE INSTALLATION
 OF THE PLUMBING. PLEASE SUBMIT A
 PLUMBING FLOOR PLAN AND SANT. RISER
 DIAGRAM THAT MEET THE CODE REQUIREMENT.
 SECTION 104.2.1.
 2) RESPONSE TO COMMENT #2 STATES "THERE
 IS CURRENTLY NO GAS SERVICE TO THE
 HOUSE". COMMENT 2D STATES "GAS LOAD
 EXISTING=130,000 BTU" PLEASE CLARIFY.
 SHOW EXISTING GAS CONNECTION TO THE
 PIPING OFF THE METER. PLEASE CLARIFY
 SECTION 104.2.1.
 3) BY NOT SHOWING THE DISTANCE FROM THE
 METER TO THE JACUZZI, WHEN THAT PIPE IS
 ADDED TO THE SYSTEM, THE PIPING FROM THE
 METER WILL HAVE TO BE CHANGED TO ACCOUNT
 FOR THE TOTAL DEVELOPED LENGTH OF THE
 SYSTEM. IF THIS IS SHOWN ON THE RISER
 DIAGRAM THE PIPE CAN BE SIZED FOR FUTURE
 APPLIANCES WHEN INSTALLED AT THIS TIME.
 TABLE 402(2).
 4) SUBMIT TWO SETS OF PLANS FOR REVIEW.
 REMOVE ALL VOIDED SHEETS AND RESUBMIT
 ONE SET FOR COMPAIRISON. SECTION
 104.2.1
  
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-11-05 Cont ID  
Sent By kstevens Date 2004-11-05 Time 08:17 Rev Time 1.25
Received By kstevens Date 2004-11-05 Time 08:17 Sent To B1
Notes
2004-11-05 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) SHT P3 SANITARY RISER DIAGRAM, EVERY
 DRY VENT SHALL RISE VERTICALLY TO A
 MINIMUM OF 6 INCHES ABOVE THE FLOOD
 LEVEL RIM OF THE HIGHEST TRAP OR TRAPPED
 FIXTURE BEING VENTED. SECTION 905.4
 2) THE FOLLOWING INFORMATION IS REQUIRED
 FOR THE GAS PERMIT:
 A) SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2001
 FUEL GAS.
 B) SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF THE CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE IF BEING
 USED)
 C) TYPE OF GAS, (NATURAL OR LP)
 D) BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2001 FUEL GAS SECS. 401.8 THRU
 402.5.2 AND TABLES 402(1) THRU 402(34)
 E) SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY< (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 THE FBC-2001 FUEL GAS APPENDIX A-USE OF
 CAPACITY TABLES(A)(3)
 F) SUBMIT CALCULATIONS FOR COMBUSTION
 AIR PER THE FBC-2001 FUEL GAS CODE SEC.
 304
 G) INDICATE THE DELIVERY PRESSURE(PSI)
 PER FBC-2001 FUEL GAS SEC 402.2. IF
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI
 3) PME SHEETS: THE DATE THAT THE
 SIGNATURE AND SEAL IS AFFIXED SHALL BE
 ENTERED ON PLANS. FAC 61G15-23.002(1)
 IF PRACTICING THROUGH A DULY AUTHORIZED
 ENGINEERING BUSINESS, ENGINEERS SHALL
 LEGIBLY INDICATE THEIR NAME, AND LICENSE
 NUMBER, AS WELL AS, THE NAME, ADDRESS
 AND CERTIFICATE OF AUTHORIZATION NUMBER
 OF THE ENGINEERING BUSINESS ON EACH
 SHEET. 61G15-23.002(2) FS 471.025
 4) RECORDS FROM DBPR STATE OF FLORIDA
 INDICATES THAT THELICENSE OF JACK A.
 GREEN IS DELINQUENT AT THIS TIME. THIS
 SHALL BE ACTIVATED PRIOR TO APPROVAL OF
 THE PLANS. (SEE ATTACHED SHEET)
 5) ARCHITECTURAL SHEETS: THE PERSONAL
 SEAL, SIGNATURE AND DATE OF THE
 ARCHITECT SHALL APPEAR ON ALL
 ARCHITECTURAL DOCUMENTS TO BE FILED FOR
 PUBLIC RECORD. 61G1-16.003 AND LICENSE
 NUMBER SHALL APPEAR ON EACH SHEET. FS
 481.219
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2005-12-08 Cont ID  
Sent By mmclean Date 2005-12-08 Time 17:24 Rev Time 0.00
Received By mmclean Date 2005-12-08 Time 17:24 Sent To I
Notes
2005-12-08 00:00:00APPROVING REVISION OF WALL.4FT HIGH
 STONE WALL SUPPORTING FOUNTAIN.

Review Stop Z ZONING
Rev No 2 Status P Date 2004-12-03 Cont ID  
Sent By mmclean Date 2004-12-03 Time 16:31 Rev Time 0.00
Received By mmclean Date 2004-12-03 Time 16:31 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2004-10-21 Cont ID  
Sent By csiegber Date 2004-10-12 Time 14:22 Rev Time 0.00
Received By mmclean Date 2004-10-21 Time 15:04 Sent To I
Notes
2004-10-21 00:00:00DENIED, NEED TO PROVIDE TWO SURVEY
 SHOWING THE ADDITION WITH SETBACKS.
 TWO FLOOR PLANS SHOWING THE ADDITION.
 CALLED CONTR MM