| Plan Review Stops For Permit 04090795 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
F |
Date |
2006-09-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-09-07 |
Time |
16:33 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2006-09-07 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2006-09-07 00:00:00 | BUILDING REVIEW CHECKLIST: | | | | | | 1- ENTRY DOORS PRODUCT APPROVAL PACKAGE | | | SUBMITTED NEED TO BE SUBMITTED UNDER A | | | SEPARATE PERMIT APPLICATION AS AGREED ON | | | PROVISO DATED 4/18/05. SEE ATTACHED | | | COPY. AGREEMENT WITH CONTRACTOR WAS TO | | | SEPARATE ENTRY DOORS FROM MAIN PERMIT TO | | | ALLOW ISSUANCE OF BUILDING PERMIT AND | | | ALLOW TIME FOR ENTRY DOORS PRODUCT | | | APPROVAL PACKAGE. | | | | | | 2- PACKAGE SUBMITTED IS FOR ANOTHER | | | PROJECT. PACKAGE SUBMITTED IS FOR PERMIT | | | #05030779 WHICH CORRESPONDS TO HOUSE | | | LOCATED AT 6050 OLIVE AVE. | | | | | | 3- MAKE SURE APPLICATION FOR SITE | | | SPECIFIC DOORS IS FILLEDCORRECTLY AND | | | IN ITS ENTIRETY. | | | | | | 4- ENGINEER WILL NEED TO PROVIDE | | | FABRICATION AND INSTALLATION | | | CERTIFICATION FOR THIS ONE OF A KIND | | | DOOR. | | | ***NOTE: | | | MR. ROBERT BROWN, LICENSE AND PERMIT | | | SERVICES MANAGER, IS THE PERSON WHO WILL | | | REVIEW THE LOCAL PRODUCT APPROVAL | | | APPLICATION. ENGINEER TO CONTACT MR. | | | BROWN AT (561)805-6652 TO COORDINATE | | | LOCAL PRODUCT APPROVAL PROCESS AND MAKE | | | SURE ALL REQUIRED INFORMATION IS | | | PROVIDED. | | | | | | 5- STORM SHUTTERS FOR DOOR: NEED TO | | | PROVIDE COMPLETE INSTALLATION SPECS FOR | | | DOOR GLASS PROTECTION. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2006-08-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-08-22 |
Time |
11:26 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2006-08-22 |
Time |
11:26 |
Sent To |
M |
|
| Notes |
| 2006-08-22 00:00:00 | RE-STAMPING PRODUCT APPROVALS. | | | SENT TO MECH. FOR RE-STAMPING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2006-08-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-08-14 |
Time |
10:21 |
Rev Time |
0.40 |
| Received By |
jgomez |
Date |
2006-08-14 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2006-08-14 00:00:00 | POLYFOAM PRODUCT APPROVAL REVISION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2006-06-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-06-01 |
Time |
10:17 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2006-06-01 |
Time |
10:17 |
Sent To |
PC |
|
| Notes |
| 2006-06-01 00:00:00 | REVISION: CONCRETE SLAB AT REAR LOGGIA. | | | PLANS UNDER "S". |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-08-03 |
Time |
10:07 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2005-08-03 |
Time |
10:07 |
Sent To |
M |
|
| Notes |
| 2005-08-03 00:00:00 | BUILDING REVIEW REMAINDER: | | | 1- CONTRACTOR TO APPLY FOR SEPARATE | | | PERMIT FOR ENTRY DOORS AS AGREED ON | | | PROVISO DATED 5-2-05. AVOID DELAYS OR | | | CONFLICTS BY APPLYING FOR THIS PERMIT | | | PRIOR TO DOORS INSTALLATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-05-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-05-02 |
Time |
11:11 |
Rev Time |
0.33 |
| Received By |
jgomez |
Date |
2005-05-02 |
Time |
11:11 |
Sent To |
PC |
|
| Notes |
| 2005-05-02 00:00:00 | REMAINDER: | | | NEED TO APPLY FOR SEPARATE PERMIT FOR | | | ENTRY DOORS AS AGREED ON. PROVIDE | | | COMPLETE INFORMATION PRIOR TO | | | INSTALLATION TO AVOID DELAY OR | | | CONFLICTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-04-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-04-18 |
Time |
12:03 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-04-18 |
Time |
12:03 |
Sent To |
E |
|
| Notes |
| 2005-04-18 00:00:00 | BUILDING REVIEW PROVISO: | | | | | | 1- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR ENTRY DOORS UNDER A | | | SEPARATE PERMIT. SEE PLANS FOR SIZE AND | | | TYPE OF DOOR. | | | | | | 2- PROVIDE SOIL TEST REPORT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-03-16 |
Time |
16:45 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-03-16 |
Time |
16:43 |
Sent To |
E |
|
| Notes |
| 2005-03-16 00:00:00 | SECOND CHECKLIST: | | | 1- DESIGNER OF RECORD TO SPECIFY ROOF | | | TILE FASTENERS. SEE SEC. 104.2.1.1 CITY | | | AMENDEMNTS TO FBC 2001. IT'S NOT THE | | | CONTRACTOR RESPONSIBILITY. THE | | | CONTRACTOR'S RESPONSIBILITY IS TO | | | PROVIDE PRODUCT APPROVAL THAT MEETS THAT | | | CRITERIA. | | | | | | 2- SOMEBODY CROSSED OUT THE ELEVATOR | | | FROM ALL PLANS AND DETAILS. IF ELEVATOR | | | IS NOT TO BE BUILT, THEN REVISE ORIGINAL | | | PLANS ACCORDINGLY. | | | | | | 3- RULE 9B-72 OFFERS TWO OPTIONS FOR | | | PRODUCT APPROVAL: FLORIDA PRODUCT | | | APPROVAL OR LOCAL PRODUCT APPROVAL. DADE | | | COUNTY ALONE IS NOT AN OFFICIAL FLORIDA | | | PRODUCT APPROVAL. MANUFACTURER NEEDS TO | | | APPLY FOR FLORIDA PRODUCT APPROVAL TO | | | THE FLORIDA BUILDING COMMISSION. | | | OTHERWISE, MANUFACTURER NEEDS TO APPLY | | | FOR LOCAL PRODUCT APPROVAL WITH THE CITY | | | OF WEST PALM BEACH. SEE | | | WWW.FLORIDABUILDING.ORG FOR ADDITIONAL | | | INFORMATION AND REQUIRMENTS. | | | CONSTRUCTION GLASS INDUSTRIES CORP. | | | NEEDS TO APPLY FOR FLORIDA OR LOCAL | | | PRODUCT APPROVAL FOR: | | | A) FIXED WINDOWS AS SHOWN ON PLANS. | | | B) CASEMENT WINDOWS. | | | C) FRENCH DOORS. | | | D) DOOR/WINDOW MULLIONS AND CLEARLY | | | INDICATE MULLION SIZE AND ALL FASTENERS. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC | | | 2001. | | | E) ENTRY DOORS WITH SIZE AS SHOWN ON | | | PLANS. | | | | | | 4- PROVIDE COMPLETE LISTING AND SPECS | | | FOR BBQ. | | | **NOTE: BBQ'S ARE DESIGNED FOR OUTDOOR | | | USE ONLY. SEE INSTALLATION LIMITATIONS | | | SPECIFIED BY MANUFACTURER. PROVIDE | | | MANUFACTURER SPECS ALLOWING INSTALLATION | | | OF BBQ IN PORCH. | | | | | | 5- STILL OWES $3709.54 FOR UPDATE VALUE | | | AND RADON FEES. | | | **NOTE: RE-SUBMITTAL FEES WILL APPLY FOR | | | NEXT SUBMITTAL. | | | | | | 6- UPDATE REFERENCE STANDARDS SHOWN ON | | | PAGE A-1. ACI EDITION TO BE USED IS 02 | | | NOT 99. SEE CHAPTER 35 (YELLOW ERRATA) | | | FBC 2001. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-14 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-11-23 |
Time |
16:41 |
Sent To |
PC |
|
| Notes |
| 2004-11-23 00:00:00 | CHECKLIST: | | | 1-PAY IMPACT FEES. BRING BACK PAID | | | RECEIPT AND STAMPED DRAWINGS. | | | | | | 2-NEED RECORDED NOTICE OF COMMENCEMENT. | | | | | | 3-ENTRY DOOR DOESN'T COMPLY WITH TABLE | | | 1004 FBC 2001. NEED 32" MIN. CLEAR | | | OPENING WHEN ONE LEAF IS OPEN. REVISE. | | | | | | 4-BEDROOM IN GUEST ROOM TO HAVE DOOR | | | THAT PROVIDES 29" CLEAR OPENING. SECTION | | | 11-11 OF FBC 2001 CHAPTER 11. | | | | | | 5-GUEST BEDROOM WINDOW DOESN'T COMPLY | | | WITH SEC. 1005.4.4 FBC 2001. MULLION | | | DOESN'T ALLOW THE 20" MIN. CLEAR | | | OPENING. REVISE AS REQUIRED. | | | **SAME COMMENT APPLY FOR DEN ROOM. (IF | | | USING THE ROOM FOR SLEEPING. OTHERWISE, | | | CLEARLY INDICATE UNDER THE DEN THAT ROOM | | | CAN NOT BE USED FOR SLEEPING PURPOSES. | | | | | | 6-ELEVATIONS AND FLOOR PLANS DON'T | | | MATCH. SEE NUMBER AND LOCATION OF | | | FIREPLACES AND REVISE/CLARIFY AS REQ'D. | | | | | | 7-PROVIDE ATTIC ACCES AT FAMILY ROOM | | | WING. SEC. 2309.6 | | | | | | 8-UPDATE CONNECTOR SCHEDULE. SEE CURRENT | | | SIMPSON CATALOGUE AND REVISE TYPE AND | | | NUMBER OF FASTENERS TO MATCH ENGINERED | | | PUBLISHED VALUES. SEE COMMENTS ON PLAN. | | | | | | 9-PROVIDE ONLY DETAILS THAT APPLY TO | | | THIS PROJECT TO EXPEDITE THE REVIEW. | | | | | | 10-SPECIFY ROOF TILE FASTENERS. SEE SEC. | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | | | | 11-PROVIDE COMPLETE DRAWINGS AND SPECS | | | FOR ELEVATOR OR APPLY FOR A SEPARATE | | | PERMIT. INCLUDING ELEVATOR MACHINE | | | ROOM. | | | | | | 12-PROVIDE FLORIDA/LOCAL PRODUCT | | | APPROVAL FOR: A) TRUSS CONNECTORS USED. | | | B) CASEMENT WINDOWS. | | | C) WINDOW/DOOR MULLIONS: CLEARLY SPECIFY | | | MULLION SIZE AND FASTENERS TO BE USED. | | | D) ARCHED WINDOWS. | | | E) FRENCH DOORS. | | | F) GARAGE SIDE DOOR. | | | G) COMPLETE PACKAGE FOR FIREPLACE LISTED | | | TO BE USED OUTDOORS. | | | H) BBQ UL LISTING AND SPECS. | | | | | | 13-OWES $3,709.54 FOR UPDATED VALUE AND | | | BALANCE DUE AT TIME OF APPLICATION. | | | | | | 14-UPDATE REFERENCE STANDARDS SHOWN ON | | | PAGE A-1. SEE COMMENTS AND CHAPTER 35 OF | | | FBC 2001 FOR CURRENT EDITION TO BE | | | USED. | | | | | | 15-SHEET A-5: "D" CONNECTOR DOESN'T | | | RESIST THE UPLIFT CALCULATED ON PLAN. | | | SEE COMMENTS ON PLAN & REVISE AS REQ'D. | | | ** SAME APPLIES TO SHEET A-6. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-03-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-22 |
Time |
13:24 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-21 |
Time |
16:29 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-27 |
Time |
07:57 |
Rev Time |
0.10 |
| Received By |
dpalmer |
Date |
2005-06-27 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2005-06-27 00:00:00 | REVISED RISER ONLY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
N |
Date |
2005-05-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-11 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-05-11 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-04-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-04-20 |
Time |
11:37 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-04-20 |
Time |
10:55 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-03-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-03-17 |
Time |
15:52 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-03-17 |
Time |
15:25 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-10-20 |
Time |
15:38 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-10-20 |
Time |
11:38 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-05 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-05 |
Time |
11:07 |
Sent To |
B |
|
| Notes |
| 2006-09-05 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-18 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-18 |
Time |
14:51 |
Sent To |
B |
|
| Notes |
| 2006-08-18 00:00:00 | TO "JGOMEZ" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-05-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-26 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-26 |
Time |
08:16 |
Sent To |
B |
|
| Notes |
| 2006-05-26 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-03-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-16 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-16 |
Time |
17:44 |
Sent To |
E |
|
| Notes |
| 2006-03-16 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-02 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-02 |
Time |
14:10 |
Sent To |
B |
|
| Notes |
| 2005-08-02 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-21 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-21 |
Time |
14:44 |
Sent To |
E |
|
| Notes |
| 2005-06-21 00:00:00 | TO "DPALMER"DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-05-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-09 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-09 |
Time |
11:38 |
Sent To |
E |
|
| Notes |
| 2005-05-09 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-04-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-08 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-08 |
Time |
14:25 |
Sent To |
B |
|
| Notes |
| 2005-04-08 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-04-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-04 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-04 |
Time |
13:21 |
Sent To |
Z |
|
| Notes |
| 2005-04-04 00:00:00 | TO "Z"BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-28 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-28 |
Time |
13:47 |
Sent To |
M |
|
| Notes |
| 2005-02-28 00:00:00 | TO PKRAUSS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-25 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-25 |
Time |
11:54 |
Sent To |
Z |
|
| Notes |
| 2005-02-25 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-10-18 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-10-04 |
Time |
11:11 |
Sent To |
PC |
|
| Notes |
| 2004-10-18 00:00:00 | TO SFD RACK/E | | 2004-10-04 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-08-04 |
Time |
08:31 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-08-04 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-03-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-14 |
Time |
16:26 |
Rev Time |
1.40 |
| Received By |
pkrauss |
Date |
2005-03-14 |
Time |
15:36 |
Sent To |
B |
|
| Notes |
| 2005-03-14 00:00:00 | PROVISO: | | | MECHANICAL PLANS ARE CODE COMPLIANT & | | | APPROVED. | | | | | | SUBMITTAL FOR THE VENTLESS FIRE PLACE IS | | | STILL UNDER SCRUTINY.PER THE | | | MANUFACTURER'S SPECIFICATIONS, WHEN THE | | | APPLIANCE IS INSTALLATED IN BUILDINGS | | | CONSIDERED "UNUSUALLY TIGHT | | | CONSTRUCTION" ADDITIONAL FRESH AIR MUST | | | BE PROVIDED.PLANS DO NOT HAVE ANY | | | CALCUALTIONS FOR COMBUSTION AIR, WHETHER | | | IT WILL BE REQUIRED OR NOT.PLANS DO | | | NOT INDICATE WHICH MODEL IS TO BE | | | INSTALLED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-21 |
Time |
09:53 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2004-11-18 |
Time |
13:30 |
Sent To |
P |
|
| Notes |
| 2004-11-18 00:00:00 | R/A IS REQUIED OUT OF DEN. | | | | | | MUST COMPLY WITH2001 FBC MECH. 601.4 | | | . | | | | | | PAT RAFTER805 6719 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-04-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-04-26 |
Time |
14:47 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2005-04-26 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2005-04-26 00:00:00 | PASSED/PROVISO | | | | | | REVISION REQUIRED - SHOWER MISSING IN | | | HER MASTER BATH - TUB MISLABELED AS | | | SHOWER IN BATH #1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
gsalfeld |
Date |
2005-03-21 |
Time |
10:18 |
Rev Time |
1.00 |
| Received By |
gsalfeld |
Date |
2005-03-21 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-10-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-21 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2005-04-18 |
Time |
10:51 |
Sent To |
M |
|
| Notes |
| 2004-10-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHT M-2 SANITARY RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN, NOR DOES IT | | | MEET CODE REQUIREMENTS. | | | A) W/C IN THE POWDER ROOM IS NOT VENTED | | | SECTION 901.2.1 | | | B) CABANA BATH SHOWN ON THE FLOOR PLAN | | | IS NOT SHOWN ON THE RISER DIAGRAM. SECT- | | | ION 104.2.1 | | | C) WASH MACHINE REQUIRES A TRAP AND A | | | STANDPIPE. ALSO A CLEANOUT IS REQUIRED | | | ON THE WASH MACHINE STACK MINIMUM 4' | | | ABOVE THE FLOOR. SECTIONS 1002.1, 802.4, | | | AND 708.10 | | | D) SHOW ALL PIPES SIZES ON THE SANT. | | | RISER DIAGRAM. SECTION 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2005-04-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-04-07 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-04-07 |
Time |
16:55 |
Sent To |
I |
|
| Notes |
| 2005-04-07 00:00:00 | NOTE: | | | 1. MUST PULL SEPERATE PERMIT FOR | | | POOL/SPA/DECK/SCREEN ENCLOSURE | | | 2. MUST PULL SEPERATE PERMIT FOR | | | GATES/WALLS/FENCE WITH CITY OF WEST PALM | | | BEACH UTILITY EASEMENT APPROVAL. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-02-28 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-02-28 |
Time |
12:39 |
Sent To |
I |
|
| Notes |
| 2005-02-28 00:00:00 | DENIED, | | | 1. THE STRUCTURE EXCEEDS THE HEIGHT | | | REQUIREMENT OF 33FT.MUST MEASURE FROM | | | THE GRADE TO THE TOP OF THE CHIMNEY. | | | MUST REDUCE CHIMNEY AND PROVIDE NEW | | | ELEVATION SHEETS.CALLED CONTR LEFT MSG | | | ON VOICE MAIL. | | | | | | MICHELLE MCLEAN | | | ZONIG TECHNICIAN | | | CONSTRUCTION SERVICES. | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-10-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-10-18 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-10-18 |
Time |
10:40 |
Sent To |
I |
|
| Notes |
| 2004-10-18 00:00:00 | DENIED, CHIMNEY IS OVER THE HEIGHT | | | REQUIREMENT. HOUSE HEIGHT MUST BE 30FT | | | AND 10% ADDITIONAL FOR CHIMENEY, MAKING | | | IT 33FT IN HEIGHT.CALLED CONTR |
|
|