| Plan Review Stops For Permit 04090769 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-10-18 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2004-10-16 |
Time |
13:09 |
Rev Time |
2.00 |
| Received By |
mjacobs |
Date |
2004-10-18 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-12-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-01 |
Time |
06:52 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-12-01 |
Time |
06:52 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-11-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-30 |
Time |
12:24 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-11-15 |
Time |
07:43 |
Sent To |
P |
|
| Notes |
| 2004-11-15 00:00:00 | ********* UNSAT ********* | | | | | | 1)NOTE: PLEASE SEE NOTE #1 FROM FIRST | | | REVIEW. | | | PLEASE CORRELATE LOAD ON LOAD | | | CALCULATIONS AND LOAD/KW RATING OF HEAT | | | PUMP ON SPEC SHEETS. LOAD ON LOAD CALCS | | | INDICATE 4.5KW? | | | NEW HEAT PUMP SPEC SHEET SHOWS ARE | | | LARGER UNIT THAN ON PREVIOUS SUBMITTAL. | | | PLEASE SEE ALL CONTINUOUS LOADS | | | (HEAT-PUMP)ARE TO BE SHOWN AT 125% ALONG | | | WITH MOTOR LOADS. | | | 215.3,230.42 ETC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-04 |
Time |
09:13 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-10-05 |
Time |
16:01 |
Sent To |
P |
|
| Notes |
| 2004-10-05 00:00:00 | ********* UNSAT ************ | | | | | | 1)NOTE: PLEASE CORRELATE RISER DIAGRAM/ | | | LOAD CALCULATIONS AND SPEC SHEET FOR | | | HEAT PUMP AND OCP. | | | | | | SHOWS 2P-25A ON LOAD CALCS, A 2P60A ON | | | SPEC SHEET AND A 2P40A ON PLANS?? | | | PLEASE SEE MIN LOAD ALSO TO BE FIGURED | | | @125% FOR CONTINUOUS LOAD OF 3 OR MORE | | | HOURS. POOL PUMP ALSO. | | | | | | 2)NOTE: PLEASE SEE WIRING DIAGRAM SHOWS | | | A NEW 200A PANEL. PLEASE CLARIFY FEED, | | | #OF CONDUCTORS, CONDUIT ETC | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE LOAD FOR A/C,OCP ETC | | | 424.3B | | | PLEASE SEE 220.31B FOR EXISTING DWELLING | | | -S. A/C AT 100%. | | | PLEASE SEE MISSING SMALL APPLIANCE | | | CIRCUITS PER 220.16, 210.11 ETC | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-30 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-30 |
Time |
12:23 |
Sent To |
E |
|
| Notes |
| 2004-11-30 00:00:00 | SENT TO "DP" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-11-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-08 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-08 |
Time |
15:09 |
Sent To |
E |
|
| Notes |
| 2004-11-08 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-10-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-04 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-04 |
Time |
09:13 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-09-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-24 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-24 |
Time |
09:37 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-11-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-24 |
Time |
05:46 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-11-24 |
Time |
05:46 |
Sent To |
|
|
| Notes |
| 2004-11-24 00:00:00 | NO CHANGES FROM PES REVIEW |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-10-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-05 |
Time |
16:01 |
Rev Time |
0.75 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
| 2004-10-16 00:00:00 | BACK FLOW PREVENTER TO BE INSTALLED | | | PRIOR TO COMMENCING WORK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-09-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-24 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|