| Plan Review Stops For Permit 04090764 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-27 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-02-27 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2007-02-27 13:24:21 | THE ARCHITECT CAME IN AND MADE REDLINE CORRECTIONS TO | | | THE REVISED PLAN SHEETS A2, A3, A4, A6, A7, A9 AND A10. | | | THEY ARE OK NOW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2007-01-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-01-24 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-01-24 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2007-01-24 17:04:34 | DENIED BY BUILDING | | | | | | 1)ALL OF THE NEW REVISIONS TO THE PLANS ARE NOT | | | CLOUDED AND MARKED WITH THE REVISION NUMBER INSIDE THE | | | TRIANGLE. | | | | | | 2) THE TITLE BLOCKS ARE MISSING THE REVISION NUMBERS ON | | | SEVERAL SHEETS. | | | | | | 3) THE REVISION DATES IN THE TITLE BLOCK HAVE BEEN | | | PARTIALLY CUT OF ON SHEET A6. | | | | | | 4) SPECIFY THE SIZES OF THE ATTIC ACCESS OPENINGS. | | | | | | 5) THE ATTIC ACCESS FROM THE SECOND FLOOR TO AHU-3 DOES | | | NOT NEED TO BE SHOWN ON THE FIRST FLOOR PLAN A-2. SHOW | | | IT AS A DOOR IN THE WALL OF CLOSET 204 ON THE SECOND | | | FLOOR PLAN A-3. | | | | | | 6) WINDOWS (B) IN THE RECONFIGURED 2ND FLOOR SHOWER ARE | | | BOTH REQUIRED TO HAVE SAFETY GLAZING OR BE IMPACT | | | RESISTANT. THE WINDOW SCHEDULE SHOWS ONLY ONE WITH | | | TEMPERED GLASS. PRODUCT APPROVALS SUBMITTED ARE FOR | | | LARGE MISSLE IMPACT GLAZING. | | | | | | 7)PLEASE CORRECT THE DOOR AND WINDOW SCHEDULE ON A-9. | | | SECOND FLOOR DOORS 71 AND 72 HAVE BEEN OMITTED BUT ARE | | | STILL SHOWN ON A-3. CHECK DOORS 15, 16, 46 AND 63 ON | | | THE FIRST FLOOR. | | | | | | 8) REVISIONS TO OTHER TRADES AFFECTED BY THESE CHANGES | | | WILL BE REQUIRED. | | | | | | 9) THE DIMENSIONS LISTED IN ROOM 128 ARE ILLEGIBLE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2006-12-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-12-07 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-12-07 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2006-12-07 16:18:37 | DENIED BY BUILDING | | | | | | REVISIONS TO SHEETS A-2(FIRST FLOOR PLAN) AND A-3 | | | (SECOND FLOOR PLAN) . | | | | | | 1)SHEETS A-2AND A-3BOTH REFERENCE THE 2004 | | | FLORIDA BUILDING CODE. THIS PROJECT IS PERMITTED UNDER | | | THE 2001 FBC. PLEASE SPECIFY 2001 FBC. | | | | | | 2) THE FRONT ELEVATION IS AFFECTED BY THE ELIMINATION | | | OF THE SECOND FLOOR WINDOW IN ROOM 206 ON SHEET A-3. | | | SUBMIT REVISED ELEVATION. | | | | | | 3) SUBMIT REVISED PLANS FOR MEP PLANS THAT WILL BE | | | AFFECTED BY THE REVISIONS TO THE BUILDING PLANS. | | | | | | 4) THE DOOR AND WINDOW SCHEDULES ON A-9NEED TO BE | | | REVISED TO REFLECT THE CHANGES TO THE FLOOR PLANS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-08-02 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-08-02 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2005-08-02 00:00:00 | 1) REVISIONS TO SHEETS A2, A4, A5, A6, | | | A7, A9, S1, S2 & S3 ARE OK. | | | | | | 2) CONTRACTOR TO SUBMIT SPECIFICATIONS | | | AND LISTING INFORMATION FOR THE VENTLESS | | | FIREPLACE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2005-07-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-07-07 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-07-07 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2005-07-07 00:00:00 | REVISION DENIED | | | | | | 1) ON SHEET A5 THERE IS AN OPENING WITH | | | ID TAG (T). THERE IS NO SUCH TAG LISTED | | | IN THE WINDOW AND DOOR SCHEDULES ON A9. | | | | | | 2) OPENING #38 IS SHOWN AS A DOUBLE | | | SCREEN DOOR ON A5, BUT IS LISTED IN THE | | | DOOR SCHEDULE AS AN ARCHED FIXED SCREEN. | | | | | | 3) THE ID TAGS FOR OPENINGS 33 AND 34 ON | | | A7 ARE LISTED IN THE DOOR SCHEDULE ON A9 | | | AS ARCHED SWING DOORS. THE REVISED DOORS | | | ARE NOT ARCHED. | | | | | | 4) THE OPENING AT THE GUEST LOGGIA IS | | | SPECIFIED AS SCREEN, BUT A PAIR OF | | | FRENCH DOORS IS SHOWN ON THE ELEVATION | | | ON A7. | | | | | | 5) THE ROOF OF THE CHIMNEY THAT WAS | | | CHANGED TO VENTLESS IS SHOWN FLOATING IN | | | THE AIR ON SHEET A7. | | | | | | 6) SUBMIT THE MANUFACTURER'S | | | SPECIFICATIONS AND LISTING FOR THE | | | VENTLESS FIREPLACE. | | | | | | 7) THE CHIMNEY SHOWN ON A4 AND A6 IS | | | REQUIRED TO EXTEND AT LEAST 3' ABOVE THE | | | HIGHEST POINT WHERE THEY PASS THROUGH | | | THE ROOF PER FBC 2804. | | | | | | 8) ON SHEET S2 THERE ARE TWO BEAM ID | | | TAGS (B16 AND B17) THAT ARE NOT LISTED | | | IN THE BEAM SCHEDULE ON S3. | | | | | | 9) COORDINATE THE OPENING ID TAGS ON A2 | | | WITH THE SCHEDULES ON A9. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-02-25 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-02-25 |
Time |
11:33 |
Sent To |
P |
|
| Notes |
| 2005-02-25 00:00:00 | PROVISO | | | | | | REVISE THE STAIR RISER AND TREAD | | | DIMENSIONS TO COMPLY WITH FBC 1007.3.1. | | | THE SUM OF TWO RISERS AND A TREAD | | | EXCLUSIVE OF THE NOSING SHALL BE NOT | | | LESS THAN 24" NOR MORE THAN 25". |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-01-10 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-01-10 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2005-01-10 00:00:00 | DENIED | | | | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3) THE SAFETY GLAZING IN BATH #2 IS | | | SPECIFIED FOR THE WRONG WINDOW. PLEASE | | | CORRECT. | | | | | | 4) SUBMIT AN AFFIDAVIT FROM THE ASPHALT | | | BASED ROOFING PRODUCT MANUFACTURER | | | CERTIFYING THE USE OF THEIR PRODUCT OVER | | | AN UNVENTED ATTIC SYSTEM. SEE ATTACHMENT | | | FROM PALM BEACH COUNTY BCAB. | | | | | | 5) SPECIFY THE SCUPPER SIZES FOR | | | DRAINING THE FLAT ROOFS. | | | | | | 6) RISER AND TREAD DIMENSIONS DO NOT | | | COMPLY WITH FBC 1007.3.1. | | | | | | 7) SHOP DRAWING WILL BE REQUIRED FOR THE | | | FLOOR SYSTEM AT THE SECOND FLOOR. | | | | | | 8) ITEM NUMBER (14) FROM THE FIRST | | | REVIEW STATES THAT BUCK FASTENING | | | DETAILS ON A10 CONFLICT WITH THOSE ON | | | S4. THE NOTES ON THE BUCK DETAILS ON A10 | | | REFER TO S4 FOR DETAILS. THERE WAS NO | | | SHEET S4 SUBMITTED. | | | | | | 9) SUBMIT STRUCTURAL DETAILS FOR | | | FIREPLACE AND CHIMNEY CONSTRUCTION. | | | SPECIFY THE REQUIRED HEIGHT OF THE | | | CHIMNEY ABOVE THE ROOF AND ROOF | | | STRUCTURES. FBC 2114.3.2 REQUIRES THE | | | FIREBOX TO HAVE A MINIMUM DEPTH OF 20" | | | AND A THROAT AT LEAST 8" ABOVE THE | | | FIREPLACE OPENING. SEE FBC 2114.3.8 FOR | | | HEARTH DIMENSIONS. | | | | | | 10) PRODUCT APPROVALS SUBMITTED | | | WITH PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE | | | AT WWW.FLORIDABUILDING.ORG. PRODUCTS | | | WITH STATEWIDE APPROVAL ARE REQUIRED TO | | | BE SUBMITTED WITH A COVER SHEET THAT | | | LISTS THE PRODUCT IDENTITY NUMBER FROM | | | THE STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. PLEASE | | | SUBMIT THE COVER SHEETS WITH THE FL | | | NUMBERS FOR EACH PRODUCT FROM THE STATE | | | WEBSITE. | | | | | | 11) SUBMIT THE FLORIDA PRODUCT APPROVALS | | | FOR ALL OF THE TRUSS CONNECTORS THAT ARE | | | SPECIFIED ON THEPLANS. | | | | | | 12) SUBMIT STATE OR LOCAL PRODUCT | | | APPROVALS WITH INSTALLATION INSTRUCTIONS | | | FOR THE FOLLOWING: | | | - ACHED TOP CASEMENT WINDOWS | | | - HOPPER WINDOWS | | | | | | 13) THE PRODUCT APPROVAL THAT WAS | | | SUBMITTED FOR THE SLIDING GLASS DOOR HAS | | | ONLY SMALL MISSLE IMPACT RATING AND WILL | | | BE REQUIRED TO BE COVERED BY STORM | | | PANELS. SUBMIT STORM PANEL PRODUCT | | | APPROVAL KEY PLAN AND INSTALLATION | | | INSTRUCTIONS. | | | | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-11-09 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-11-09 |
Time |
08:03 |
Sent To |
|
|
| Notes |
| 2004-11-09 00:00:00 | DENIED | | | | | | 1)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | | | | 2)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | | | | 3) FBC* 1804.2.2AREA OF QUESTIONABLE | | | SOIL.SUBMIT A GEOTECHNICAL REPORT | | | TO VERIFY THE SAFE BEARING CAPACITY OF | | | THE SOIL. | | | | | | 4) THE WINDOW (G) IN BEDROOM #2 IS | | | SPECIFIED AS A 2' X 4' CASEMENT WINDOW | | | ON THE SCHEDULE ON A9. VERIFY THAT THIS | | | WILL MEET THE CLEAR OPENING REQUIREMENTS | | | OF FBC 1005.4. | | | | | | 5) FBC 2405.2 REQUIRES SAFETY GLAZING IN | | | WINDOWS WITHIN 3' HORIZONTALLY AND LESS | | | THAN 60" ABOVE THE WALKING OR STANDING | | | SURFACES AT TUBS OR SHOWERS. PLEASE | | | SPECIFY ON THE PLANS THAT THE WINDOWS IN | | | THE MASTER BATH AND BATH #1 AT THE | | | SHOWER ARE TO HAVE SAFETY GLAZING IF | | | THEY ARE WITHIN THESE AREAS. | | | | | | 6) 61G-16.004 OF THE FAC REQUIRES THE | | | PRINTED NAME OF THE PERSON SEALING THE | | | DOCUMENT ON EACH PLAN SHEET. | | | | | | 7) SPECIFY THE LOCATION AND THE MINIMUM | | | SIZE OF THE ATTIC ACCESSES AS REQUIRED | | | BY FBC 2309.6. | | | | | | 8) THE NOTE ON A8 SPECIFIES ATTIC | | | VENTILATION AND THE WALL SECTIONS ON A11 | | | SPECIFY AN ICYNENE FOAM INSULATION | | | SYSTEM WHICH IS VENTLESS. PLEASE | | | CLARIFY. SPECIFY THE NUMBER SIZE AND | | | SPACING OF ATTIC VENTS OR SUBMIT THE | | | DESIGN DRAWINGS FROM A FLORIDA | | | REGISTERED DESIGN PROFESSIONAL, THE | | | ICYNENE SPECIFICATIONS FROM THE | | | MANUFACTURER AND AN AFFIDAVIT CERTIFYING | | | THE USE OF THE ASPHALT BASED ROOFING | | | PRODUCTS OVER AN UNVENTED SYSTEM. | | | SPECIFY THE R-VALUE OF THE INSULATION. | | | | | | 9) PROVIDE DETAILS OF THE FLAT ROOFS AND | | | INDICATE HOW DRAINAGE WILL BE ACHIEVED. | | | | | | 10) REVISE THE BOTTOM RAIL NOTE ON A10 | | | TO STATE FLOOR OR DECK AND NOT ROOF. | | | | | | 11) SPECIFY THE RISER HEIGHTS AND TREAD | | | DEPTHS FOR THE STAIRS. SPECIFY THE | | | | | | 12) SPECIFY THE EMBED DEPTH OF THE | | | EXPANSION BOLTS AT THE TOP OF THE GARAGE | | | DOOR BUCKS ON A10. | | | | | | 13) SHOP DRAWINGS WILL BE REQUIRED TO BE | | | SUBMITTED FOR APPROVAL FOR THE SECOND | | | FLOOR SYSTEM. | | | | | | 14) THE BUCK DETAILS ON A10 CONFLICT | | | WITH THE BUCK FASTENING DETAILS ON S4. | | | PLEASE CORRECT. | | | | | | 15) BUCK DETAILS ON A10 SPECIFY 2-1/2" | | | TAPCONS WITH 1-1/2" EMBED THROUGH A 2X | | | BUCK. THIS IS NOT POSSIBLE. PLEASE | | | CORRECT. | | | | | | 16) SUBMIT DETAILS FOR FIREPLACE AND | | | CHIMNEY CONSTRUCTION. SHOW DIMENSIONS, | | | HEIGHT ABOVE ROOF AND COMPLIANCE WITH | | | FBC 2113, 2114, 2804 & 2806. | | | | | | 17) SUBMIT CUT SHEETS FOR THE ELEVATOR. | | | SPECIFY LOCATION OF ELEVATOR EQUIPMENT, | | | GUIDE RAIL ATTACHMENTS, ETC. | | | | | | 18) THE BEAM SCHEDULE ON S3 HAS 2 NOTE | | | B. ONE SHOULD BE NOTE C. PLEASE | | | CORRECT. | | | | | | 19) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. | | | SUBMIT PRODUCT APPROVALS FOR THE | | | FOLLOWING: | | | - TRUSS CONNECTORS | | | - CUSTOM MAHOGANY ENTRY DOORS | | | - ARCHED TOP FRENCH DOORS WITH AND | | | WITHOUT SIDELITES | | | - RADUIS CASEMENT WINDOWS | | | - HOPPER WINDOW | | | - SLIDING GLASS DOOR | | | | | | 23) THE PRODUCT APPROVAL INSTALLATION | | | DRAWINGS FOR THE CLOPAY GARAGE DORRS ARE | | | ILLEGIBLE. SUBMIT LEGIBLE COPIES. | | | | | | 24) SOME OF THE NOAS THAT WERE SUBMITTED | | | ARE NOT THE CORRECT ONES FOR THE FLORIDA | | | PRODUCT APPROVALS THAT WERE GIVEN. | | | PLEASE SUBMIT THE CORRECT NOAS OR OTHER | | | EVALUATION LISTED ON THE STATE WEB | | | SITE. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | | | | | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2007-04-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-03 |
Time |
08:36 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-04-03 |
Time |
08:31 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-03-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-23 |
Time |
08:39 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2007-03-23 |
Time |
07:17 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-03-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-12 |
Time |
08:39 |
Rev Time |
2.00 |
| Received By |
btrobaug |
Date |
2007-03-06 |
Time |
17:12 |
Sent To |
PC |
|
| Notes |
| 2007-03-12 08:39:31 | | | | | | | REVISION DENIED/INCOMPLETE INFORMATION. | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW | | | | | | 1} THE PANEL SCHEDULES MUST INCLUDE BRANCH/FEEDER | | | CIRCUIT CONDUCTOR AND OVER CURRENT PROTECTION SO THAT | | | COMPLIANCE MAY BE REVIEWED PER 106.3.5.4 FBC AS | | | AMENDED. SEE PERMITTED SET . | | | | | | 2} THE SCHEDULES MARKED "GENERAL, CENTER AND LEFT" IS | | | UNACCEPTABLE AND CANNOT BE CORRELATED WITH LOCATION OF | | | THE PANELS ON THE PLAN. INDICATE THE PANEL DESIGNATIONS | | | AT THE LOCATION AND ON THE SCHEDULE. | | | | | | 3} COMPLETE THE SERVICE CALCULATION. INDICATE SERVICE | | | AMPERAGE. 215.5. | | | | | | 4} A WOOD FUELED PIZZA OVEN SHOULD NOT BE IN THE | | | ELECTRICAL CALCULATIONS. PLEASE REMOVE SAME. | | | | | | 5} THE POOL PANEL LOCATION SHOWN ON THE PLAN IS IN | | | VIOLATION OF 110.26 CLEARANCE REQUIREMENTS. PLEASE | | | VISIT THE SITE FOR ACTUALLOCATIONS AND ADJUST THE | | | DRAWING ACCORDINGLY. | | | | | | 6} THE CONDENSER DISCONNECTS APPEAR TO BE IN VIOLATION | | | OF 110.26, PLEASE VERIFY CLEARANCES OF 3' OR MORE. | | | | | | 7} THERE IS A LUTRON LIGHTING CONTROL SYSTEM INDICATED | | | ON THE DRAWING, THIS SYSTEM COST MUST BE ADJUSTED FOR, | | | AS IT WAS NOT PART OF THE ORIGINAL PLAN. PLEASE | | | INDICATE THE INCREASED VALUE TO THE PERMIT CLERK AND | | | OBTAIN A PAID RECEIPT FOR SAME PRIOR TO RESUBMITTING | | | CORRECTED REVISIONS. 108.3 FBC AS AMENDED. | | | | | | 8} THE RISER DIAGRAM INCORRECTLY INDICATES THE CONDUIT | | | FEEDING THE " HOUSE PANEL ", GOING TO THE TRANSFER | | | SWITCH. ALSO SHOWS CONDUIT FROM THE " HOUSE PANEL" TO | | | THE METER/MAIN. INDICATE DESIGNATION FOR THE "HOUSE | | | PANEL" (SEE NOTE #2). CORRELATE THE RISER DIAGRAM. | | | | | | 9} THE GENERATOR EQUIPMENT INDICATED ON THE PLAN MUST | | | BE PERMITTED SEPARATELY. SUBMIT SPECIFICATIONS AND | | | PLANS FOR SAME UNDER A RESIDENTIAL GENERATOR | | | APPLICATION. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-02-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-15 |
Time |
11:11 |
Rev Time |
2.00 |
| Received By |
btrobaug |
Date |
2007-02-15 |
Time |
06:43 |
Sent To |
PC |
|
| Notes |
| 2007-02-15 11:11:28 | | | | | | | REVISION DENIED/INCOMPLETE INFORMATION | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | THE FOLLOWING NEED TO BE ON THE PLAN, ON THE SHEETS | | | THAT ARE BEING REVISED. PLEASE KEEP IN MIND THE SHEET | | | THAT IS BEING REPLACED WILL BE BASICALLY VOIDED. ALL | | | INFORMATION THAT PERTAINS TO THAT SHEET MUST THEREFORE | | | APPEAR ON THE REVISED SHEET. | | | | | | 1} PROVIDE A RISER DIAGRAM WITH CONDUCTOR AND CONDUIT | | | SIZE AND TYPE, GROUNDING DETAILS, LOAD CALCULATIONS, | | | PANEL SCHEDULES, SERVICE EQUIPMENT AND PANEL LOCATIONS | | | PER 106.3.5.4 FBC. NOTE THERE IS A GENERATOR PANEL NOW | | | SHOWN ON THE PLAN, THERE WAS NO GENERATOR APPLICATION | | | OR PERMIT FOR THIS RESIDENCE. | | | | | | 2} PER 110.9 AND 110.10: OBTAIN THE | | | AVAILABLE FAULT CURRENT AT THE UTILITY | | | AND CALCULATE THE SAME AT THE EQUIPMENT. | | | INDICATE THE AIC RATING FOR THE | | | EQUIPMENT IS EQUAL TO OR GREATER THAN | | | THE AVAILABLE FAULT. | | | | | | 3} PROVIDE PANEL SCHEDULES PER 408.4. | | | | | | 4}PROVIDE LOAD CALCULATIONS PER ARTICLE 220. INDICATE | | | WHICH SECTION IS BEING USED. | | | | | | 5} RECEPTACLES ARE REQUIRED TO BE GFI PROTECTED IN THE | | | BATHROOMS PER 210.8(A)(1). SOME ARE MISSING THAT | | | DESIGNATION ON THE PLAN. | | | | | | 6} RECEPTACLES ARE REQUIRED TO BE GFI PROTECTED FOR THE | | | KITCHENCOUNTERTOPS PER 210.8(A)(6)). | | | | | | 7} AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED AT | | | EACH ISLAND COUNTER SPACE WITH A LONG DIMENSION OF 600 | | | MM (24 IN.) OR GREATER AND A SHORT DIMENSION OF 300 MM | | | (12 IN.) OR GREATER. 210.52.(C)(2). | | | | | | 8} WET BAR SINKS- WHERE THE RECEPTACLES ARE INSTALLED | | | TO SERVE THE COUNTERTOP SURFACES AND ARE LOCATED WITHIN | | | 1.8 M (6 FT) OF THE OUTSIDE EDGE OF THE WET BAR SINK., | | | GFI PROTECTED 210.8(A)(7). | | | | | | 9}SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | | UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | | A MIN OF 3' FROM BATHROOM DOORS AND | | | KITCHENS. | | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | | | | | 10} THE DISCONNECTS FOR THE CONDENSING UNITS ARE | | | MISSING FROM THE PLAN INDICATE LOCATION PER 440.14 AND | | | CLEARANCE PER 110.26. | | | | | | 11} THE ARCHITECTS SEAL IS NOT LEGIBLE ON THE PLAN | | | 481.221 FAC. | | | | | | 12} THERE ARE NO CLOUDS, HIGHLIGHTS OR DELTA 'S ON THE | | | PLAN TO INDICATE AREAS IF REVISION. PLEASE INCLUDE SAME | | | PER 106.1.3 FBC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-02-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-09 |
Time |
15:58 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-02-09 |
Time |
14:54 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-05 |
Time |
11:37 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-03 |
Time |
09:47 |
Sent To |
M |
|
| Notes |
| 2005-01-05 00:00:00 | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE ARCHITECT DID NOT SEAL SHEET | | | E-2. | | | | | | 2} THE GROUNDING SYSTEM AND THE | | | GROUNDING ELECTRODE CONDUCTOR MUST | | | COMPLY WITH 250.50, 250.52,(FOOTER | | | STEEL) AND 250.66 (1/0). | | | | | | 3} THE DISCONNECTS FOR THE CONDENSING | | | UNITS MUST COMPLY WITH | | | 110.26(CLEARANCE) | | | IT DOES NOT APPEAR THIS IS POSSIBLE | | | GIVEN THE PROXIMITY OF THE PRIVECY | | | WALL. | | | | | | 4} THERE ARE FIVE PANELS SHOWN ON THE | | | RISER AND ONLY THREE ON THE PLAN. PLEASE | | | SHOW AND LABEL ALL THE SERVICE | | | EQUIPMENT. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-10-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-10-15 |
Time |
14:09 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-10-15 |
Time |
12:33 |
Sent To |
M |
|
| Notes |
| 2004-10-15 00:00:00 | | | | PLEASE SUBMIT LOAD CALCULATIONS AND A | | | RISER DIAGRAM PER 215.5 NEC. ALSO | | | SUBMIT PANEL SCHEDULES SO THAT BRANCH | | | CIRCIUT CODE COMPLIANCE MAY BE REVIEWED. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2007-04-02 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-04-02 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-04-02 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2007-04-02 17:32:32 | TO BILL TROBAUGH |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2007-03-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-06 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-06 |
Time |
16:08 |
Sent To |
E |
|
| Notes |
| 2007-03-06 16:08:56 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-14 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-14 |
Time |
09:33 |
Sent To |
M |
|
| Notes |
| 2007-02-14 09:33:39 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-14 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-14 |
Time |
09:28 |
Sent To |
E |
|
| Notes |
| 2007-02-14 09:29:08 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-14 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-14 |
Time |
09:14 |
Sent To |
P |
|
| Notes |
| 2007-02-14 09:19:56 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-01-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-23 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-23 |
Time |
12:55 |
Sent To |
M |
|
| Notes |
| 2007-01-23 12:55:23 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-01-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-23 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-23 |
Time |
10:43 |
Sent To |
B |
|
| Notes |
| 2007-01-23 10:44:45 | TO "RMCDOUGAL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-12-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-05 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-05 |
Time |
09:37 |
Sent To |
B |
|
| Notes |
| 2006-12-05 09:37:31 | TO "RMCDOUGAL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-12-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-05 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-05 |
Time |
09:36 |
Sent To |
P |
|
| Notes |
| 2006-12-05 09:36:27 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-12-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-05 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-05 |
Time |
09:34 |
Sent To |
M |
|
| Notes |
| 2006-12-05 09:34:40 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-08-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-10 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-10 |
Time |
11:16 |
Sent To |
M |
|
| Notes |
| 2006-08-10 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-07-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-21 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-21 |
Time |
14:23 |
Sent To |
B |
|
| Notes |
| 2005-07-21 00:00:00 | TO "RMCDOGAL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-07-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-01 |
Time |
17:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-01 |
Time |
17:55 |
Sent To |
B |
|
| Notes |
| 2005-07-01 00:00:00 | TO "RMCDOUGAL" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-02-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-04 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-04 |
Time |
09:59 |
Sent To |
E |
|
| Notes |
| 2005-02-04 00:00:00 | TO "B TROBAUG" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-29 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-29 |
Time |
11:18 |
Sent To |
E |
|
| Notes |
| 2004-12-29 00:00:00 | TO "BT" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-12-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-21 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-21 |
Time |
13:09 |
Sent To |
Z |
|
| Notes |
| 2004-12-21 00:00:00 | SENT TO "Z" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-11-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-10-14 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-02-25 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2004-10-15 00:00:00 | TO SFD RACK/E | | 2004-09-24 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2007-03-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2007-03-19 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2007-03-19 |
Time |
08:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-20 |
Time |
08:44 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-02-20 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2007-02-20 08:45:00 | REVISION TO MECH. PLANS AND E-CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2007-01-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-31 |
Time |
11:00 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2007-01-31 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2007-01-31 11:32:03 | MECHANICAL REVISION | | | *** DENIED *** | | | 1) PLEASE SHOW ON ENERGY CALCULATIONS SEER FOR 3 OTHER | | | UNITS, LINE 12 C. | | | | | | 2) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | | ALSO, PER 2004 FBC 13-600.3.ABC.2. | | | | | | 3) ENERGY CALCULATIONS SHOW TWO GAS WATER HEATERS, LINE | | | 14 A, AND B, PLEASE SHOW THE LOCATION OF THE GAS WATER | | | HEATERS ON THE MECHANICAL PLANS, AND PROVIDE COMBUSTION | | | AIR IF REQUIRED. | | | | | | 4) MECHANICAL PLANS PAGE A/C1 SHOW TWO CU4 CONDENSER | | | UNITS, PLEASE CORRECT. | | | | | | 5) ARCHITECTURAL FIRM'S ADDRESS AND PHONE NUMBER MUST | | | APPEAR IN THE TITLE BLOCK, PER FAC 61G1-16.004. | | | | | | 6) ARCHITECT SEAL IS NOT LEGIBLE, IF SEAL CAN NOT BE | | | READ PLANS WILL NOT PASS REVIEW, PLEASE CORRECT. | | | | | | 7) ARCHITECT NEEDS TO DATE HIS SIGNATURE AT THE SEAL, | | | PER FAC 61G1-16.004. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2006-12-05 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2006-12-05 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2006-12-05 |
Time |
18:30 |
Sent To |
PC |
|
| Notes |
| 2006-12-05 19:06:17 | -----------------DENIED----------------- | | | | | | 1. REVISED ENERGY CALCULATIONS AND MANUAL J IS | | | REQUIRED. SEE PREVIOUS REVIEW NOTE #3 (ATTACHED). | | | | | | 2. AHU#2: PLEASE SHOW 10" FLEX ON SUPPLY GOING TO | | | DISTRIBUTION BOX RATHER THAN THE 8X4 GRILL. | | | | | | 3. AHU#2: THERE IS NO RETURN DUCT SHOWN FROM 24X14 R?A | | | GRILL TO AHU. | | | | | | 4. AHU#3: DUCT SIZE IS MISSING ON SUPPLY FLEX THAT IS | | | FEEDING THE DISTRIBUTION BOX IN THE FOYER/DINING ROOM | | | AREA. | | | | | | 5. AHU#5: THE SUPPLY FLEX FEEDING THE DISTRIBUTION BOX | | | IN THE FAMILY ROOM IS MARKED AS BOTH 10" AND 12". | | | PLEASE CLARIFY BY REMOVING THE INCORRECT SIZE. | | | | | | 6. AHU#5: THE DISTRIBUTION BOX SERVING THE PANTRY AND | | | BREAKFAST NOOK IS BEING FED BY A 5" FLEX. PLEASE | | | CORRECT. | | | | | | 7. PAGE A/C-1 SHOWS SIX CONDENSERS. THERE ARE ONLY 5 | | | SYSTEMS. PLEASE CLARIFY. | | | | | | 8. THERE ARE AHUS ON FIRST AND SECOND FLOORS MARKED AS | | | AHU#2, WHILE THERE IS NO UNIT MARKED AS AHU#1. PLEASE | | | CORRECT. | | | | | | 9. THERE ARE TWO DIFFERENT SYSTEMS ON THE EQUIPMENT | | | SCHEDULE MARKED AS SYSTEM #3. PLEASE CORRECT. | | | | | | 10. MECHANICAL NOTE #7 SHOWS 200 CFM FRESH AIR REQUIRED | | | ON FIRST FLOOR. HOW IS THIS TO BE PROVIDED. PLEASE | | | INDIATE ON THE PLANS. | | | | | | 11. MECHANICAL NOTE #9, THIS REQUIREMENT DOES NOT APPLY | | | TO ONE AND TWO FAMILY DWELLINGS. YOU MAY REMOVE THIS | | | NOTE OR A FAN SHUT-DOWN TEST WILL BE REQUIRED FOR ALL | | | A/C SYSTEMS AT THE FINAL INSPECTION. | | | | | | 12. THE SERVICE PANEL OF ATTIC EQUIPMENT MUST BE | | | LOCATED WITHIN SIX FEET OF THE ATTIC ACCESS (SCUTTLE | | | HOLE) PER FBC CHAPTER 13, SEC 610.1.ABC.3.5.2 | | | | | | REVIEWED BY: | | | RONALD J REGUEIRO | | | 561.805.6734 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-11 |
Time |
11:32 |
Rev Time |
1.15 |
| Received By |
tgordon |
Date |
2006-08-11 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2006-08-11 00:00:00 | *** DENIED *** | | | 1) PLANS ON FILE WERE DONE BY AN ARCTECT | | | (PATRICK SEGRAVES) AND ONLY HE CAN MAKE | | | REVISIONS TO THE MECHANICAL PLANS. | | | | | | 2) PLANS NEED THE JOB ADDRESS ON THEM. | | | | | | 3) MANUAL J CALCULATIONS ON FILE ARE | | | CALLING FOR 73,749 SENSIBLE BTU'S, THE | | | MECHANICAL PLANS ARE CALLING FOR 145,880 | | | SENSIBLE BTU'S, THE PLANS CAN ONLY CALL | | | FOR 20% MORE THAN THE MANUAL J CAL'S, | | | PER 2001 FBC 13-607.1.ABC.1.1, YOU HAVE | | | ABOUGHT 8 TONS TO MUCH. IF YOU ARE | | | PLANING TO KEEP THIS AMOUNT OF COOLING | | | YOU NEED TO SUBMIT NEW ENERGY | | | CALCULATIONS AND MANUAL J CALCULATIONS. | | | | | | 4) SHOW ATTIC ACCESS TO AHU ON PLANS. | | | | | | 5) NEED TO PROVIDE RETURN AIR TO THE | | | LIBRARY. | | | | | | 6) RETURN AIR GRILL 36X16 TO AHU #5 IS | | | TO SMALL FOR A 5 TON SYSTEM PLEASE | | | CORRECT. | | | | | | 7) AHU #1 RETURN AIR DUCT TO 30X18 GRILL | | | IS NOT SIZED. | | | | | | 8) CHECK ALL SUPPLY AIR GRILLS FOR SIZE | | | AND CFM'S SOME ARE MISSING THIS | | | INFORMATION. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-02-10 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-02-10 |
Time |
11:03 |
Rev Time |
2.00 |
| Received By |
prafter |
Date |
2005-02-10 |
Time |
11:03 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-06 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
prafter |
Date |
2005-02-10 |
Time |
11:01 |
Sent To |
P |
|
| Notes |
| 2005-01-06 00:00:00 | 1. A.H.U. IN ATTIC AREA MUST CONFORM | | | WITH 2001 FBC/M 306.3 FOR ACCESS AND | | | SERVICE SPACE . | | | 2. THE R/A DUCT FOR LIBARY REFLECT 10" | | | ,SHOULD BE 14". 2001 FBC/M 604.1 | | | BALLANCE RETURN AIR . | | | 3. MASTER BATHROOM 208 REQUIREDS | | | EXHAUST FAN. FBC/M 402.3.1 . | | | 4. PROVIDE MANF. INFORMATION FOR HOOD | | | REFLECTED ON A-7.2 DRAWING 06-02-04 . | | | HOOD COVERS PIZZA OVEN /GRILL /COOKTOP | | | . | | | 5. THERMADOR OUTDOOR COOKTOP MODEL SB2B | | | AND THERMADOR CHAR GLO OUTDOOR BARBECUE | | | ARE LISTED FOR OUTDOOR ONLY . | | | 6.MODEL 60/THE HOME OVED DOES NOT | | | REFLECT MANF. LISTING LOCATION USAGE . | | | PAT RAFTER 561/805/6725 OR 805/6719 . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-10-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-10-15 |
Time |
14:10 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-10-25 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2004-10-25 00:00:00 | DENIED: | | | 1.PLEASE PROVIDE MANUAL J CALUCALTIONS | | | PER 2001 FBC CHAPTER 13 SUB-CHAPTER 6 | | | SECTION 607.1.ABC.1. | | | | | | 2.AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 FBC(M) | | | 307.2.3. | | | | | | 3.PROVIDE ADDITIONAL INFORMATION ON | | | THE PIZZA OVEN, GRIDDLE AND 2 BURNER | | | STOVE IN THE LANAI AREA.WILL THESE | | | APPLIANCES BE GAS OR ELECTRIC?PROVIDE | | | MANUFACTURER SUBMITTAL DATA AND VENTING | | | INFORMATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-27 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-27 |
Time |
08:51 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2007-02-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-22 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-22 |
Time |
08:52 |
Sent To |
B |
|
| Notes |
| 2007-02-22 08:58:32 | DENIED; | | | 1. GAS WATER HEATERS TO BE INSTALLED ON OUTSIDE OF | | | BUILDING NOT IN GARAGE. | | | 2. SANITARY RISER DIAGRAM PAGE A-10. | | | A) 1ST FLOOR W/M NOT VENTED. | | | B) 2ND FLOORW/M NOT SHOWN | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-12-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-12-27 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-12-27 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2006-12-27 08:26:31 | REVISED SANITARY RISER DIAGRAM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-02-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-02-26 |
Time |
06:30 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-02-26 |
Time |
06:30 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-07 |
Time |
08:58 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-01-07 |
Time |
08:58 |
Sent To |
B |
|
| Notes |
| 2005-01-07 00:00:00 | DENIED; | | | EXER. BATH; SHOWER NOT VENTED (WET VENT | | | TO BE UP STREAM OF TOILET). MECHANICAL | | | VENT REQUIRED FOR LAV. | | | BOTH CLOTHES WASHERS; SHOW STAND PIPE | | | AND CLEANOUT ABOVE WASHER DRAIN AT 48" | | | AFF. SEE RED LINE ON RISER DIAGRAM. | | | BATHROOM ONE; SHOWER NOT VENTED (WET | | | VENT TO BE UPSTREAM OF TOILET. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-11-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-04 |
Time |
17:17 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2004-11-04 |
Time |
17:17 |
Sent To |
B |
|
| Notes |
| 2004-11-04 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | | | | A) SHT A-10 SANITARY RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN, NOR DOES IT | | | MEET CODE REQUIREMENTS. | | | 1) LANAI BAR SINK SHALL CONNECT | | | DOWNSTREAM OF THE HORIZONTAL WET VENT OF | | | THE BATHROOM FIXTURES. SECTION 909.1 | | | 2) VENTING FOR THE EXERCISE LAV AND THE | | | LANAI BAR SINK IS NOT APPROVED. (SEE THE | | | VENTING FOR THE OTHER BAR SINK). | | | 3) WASH MACHINE NOT VENTED, REQUIRES A | | | STANDPIPE, AND A CLEANOUT IS REQUIRED 4' | | | ABOVE THE FLOOR FOR ACCESS. SECTIONS | | | 1002.1, 802.4, 708.10 | | | 4) KITCHEN SINK DOES NOT REFLECT THE | | | FLOOR PLAN AS THE SINK IS SOUTH OF THE | | | VEG. SINK NOT WEST OF VEG. SINK) SECTION | | | 104.2.1. | | | 5) BAR SINK IS MISSING. SECTION 104.2.1 | | | 6) RISER DIAGRAM SHOWS 2 LAVS IN BATH | | | #2 | | | BUT THE FLOOR PLAN SHOWS ONLY 1 LAV. | | | 7) HALL BAR SINK ON THE RISER DIAGRAM IS | | | NOT SHOWN ON THE FLOOR PLAN. SECTION | | | 104.2.1. | | | 8) 2ND FLOOR SHOWS 2 WATER CLOSETS ON | | | THE RISER DIAGRAM BUT ONLY ONE ON THE | | | FLOOR PLAN. SECTION 104.2.1 | | | 9) THE BIDET IS NOT VENTED. SECTION | | | 901.2.1. | | | 10) WASH MACHINE SHALL CONNECT | | | DOWNSTREAM OF THE BATHROOM FIXTURES. | | | SECTION 909.1 AND IS NOT VENTED. SECTION | | | 901.2.1. | | | 11) THE LAVS ON THE RISER DIAGRAM FOR | | | THE MASTER BATH DO NOT REFLECT THE FLOOR | | | PLAN. LAVS ON SEPARATE WALLS AND EAST OF | | | THE SHOWER. (SEE FLOOR PLAN). SECTION | | | 104.2.1. | | | B) 61G1-16.003 THE PERSONAL SEAL, | | | SIGNATURE, AND DATE ARE REQUIRED ON | | | SIGNED AND SEALED PLANS. - NO DATE ON | | | THE SEAL. FS 481.2055 - 61G1-16.004(5) | | | C) 61G1-16.004(6) A SPACE FOR THE | | | PRINTED NAME OF THE PERSON SEALING THE | | | DOCUMENT. FS 481.2055 | | | D) MAKE CORRECTIONS TO RISER DIAGRAM AND | | | RESUBMIT FOR REVIEW. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-12-29 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-12-29 |
Time |
09:39 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-10-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-10-14 |
Time |
09:43 |
Rev Time |
0.20 |
| Received By |
mmclean |
Date |
2004-10-14 |
Time |
09:43 |
Sent To |
I |
|
| Notes |
| 2004-10-14 00:00:00 | DENIED, NEED TO REMOVE THE DRIVEWAY OUT | | | OF THE 10FT EASEMENT.THE LANAI WITH | | | GRIDDLE, 2 BURNER, PIZZA OVEN, SINKS, | | | BAR NEEDS TO BE REMOVED OR PUT OUTSIDE. | | | IT'S INTERIOR AND WILL BE CONSIDER | | | ANOTHER KITCHEN TO THE HOUSE.CALLED | | | SHELDON. MM |
|
|