Plan Review Details - Permit 04090582
Plan Review Stops For Permit 04090582
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-11-17 Cont ID  
Sent By lsmith Date 2004-11-17 Time 15:30 Rev Time 1.00
Received By lsmith Date 2004-11-17 Time 15:29 Sent To  
Notes
2004-11-17 00:00:00RECEIVED CORRECTED PRODUCT APPROVALS FOR
 THE IMPACT GLASS FIXED WINDOWS.LS

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-11-08 Cont ID  
Sent By lsmith Date 2004-11-08 Time 09:58 Rev Time 1.00
Received By lsmith Date 2004-11-08 Time 09:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-10-26 Cont ID  
Sent By kstevens Date 2004-10-21 Time 12:53 Rev Time 4.00
Received By lsmith Date 2004-10-26 Time 11:29 Sent To  
Notes
2004-10-26 00:00:00BUILDING PLAN REVIEW: FAILED
  
 1. THE ENERGY CODE FORM HAS TO BE
 SIGNED BY THE OWNER/AGENT.
  
 2.THERE ARE NO PRODUCT APPROVALS FOR
 THE CASEMENT WINDOWS SHOWN ON THE PLANS.
  
 3. THERE ARE PRODUCT APPROVALS FOR
 THERMA-TRU DOORS THAT REQUIRE STORM
 PANELS.
  
 4. THE FIXED WINDOWS ARE "SMALL MISSLE
 IMPACT". WHEN INSTALLED UNDER 30' THEY
 REQUIRE STORM PANELS.NO STORM PANEL
 INFORMATION SUBMITTED.
  
 5. ADDITIONAL FEES ARE DUE BEFORE
 PERMITCAN BE ISSUED INCLUDING APPROACH
 FEE.
  
 6. NO GLASS BLOCK SHOWN ON PLANS BUT
 PRODUCT APPROVAL SUBMITTED. REMOVE ALL
 PRODUCT APPROVALS FOR ITEMS NOT ON PLANS
  
 7. A NOTICE OF COMMENCEMENT MUST BE
 FILED AT THE COUNTY CLERK OFFICE &
 SUBMITTED BEFORE A PERMIT CAN BE ISSUED.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2007-03-13 Cont ID  
Sent By btrobaug Date 2007-03-13 Time 13:24 Rev Time 0.50
Received By btrobaug Date 2007-03-13 Time 13:10 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2007-03-06 Cont ID  
Sent By btrobaug Date 2007-03-06 Time 12:38 Rev Time 0.50
Received By btrobaug Date 2007-03-05 Time 14:36 Sent To PC
Notes
2007-03-06 12:17:23 
  
 REVISION DENIED
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 THE WIRE SIZE AND OCPDO NOT COMPLY WITH 240 OR
 310.16, OR BOTH IN THE FOLLOWING:
 1} CIRCUIT 1&3,5&7, AND 9&11 PANEL "A".
 2} CIRCUITS 2&4 PANEL"C".
  
 ALTHOUGH #6 CONDUCTORS ON A 30 AMP OCP ARE NOT A
 VIOLATION, THEY WILL NOT PHYSICALLY FIT ON THE BREAKER.
 AND MUST BE INSTALLED PER PLAN, OR CHANGE THE PLAN TO
 INDICATE ACTUAL CONDITIONS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-12-22 Cont ID  
Sent By btrobaug Date 2006-12-22 Time 12:46 Rev Time 0.50
Received By btrobaug Date 2006-12-22 Time 11:54 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-03-27 Cont ID  
Sent By btrobaug Date 2006-03-27 Time 17:13 Rev Time 0.50
Received By btrobaug Date 2006-03-27 Time 16:55 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-11-17 Cont ID  
Sent By btrobaug Date 2004-11-17 Time 13:42 Rev Time 0.50
Received By btrobaug Date 2004-11-17 Time 13:33 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-10-14 Cont ID  
Sent By btrobaug Date 2004-10-14 Time 17:24 Rev Time 0.50
Received By btrobaug Date 2004-10-14 Time 16:55 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-02-28 Cont ID  
Sent By adarroug Date 2007-02-28 Time 11:48 Rev Time 0.00
Received By adarroug Date 2007-02-28 Time 11:48 Sent To E
Notes
2007-02-28 11:48:25TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-12-17 Cont ID  
Sent By adarroug Date 2006-12-17 Time 13:40 Rev Time 0.00
Received By adarroug Date 2006-12-17 Time 13:40 Sent To E
Notes
2006-12-17 13:40:53TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-03-23 Cont ID  
Sent By dpalmer Date 2006-03-23 Time 14:08 Rev Time 0.00
Received By dpalmer Date 2006-03-23 Time 14:08 Sent To E
Notes
2006-03-23 00:00:00TO BT'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-07-08 Cont ID  
Sent By adarroug Date 2005-07-08 Time 11:48 Rev Time 0.00
Received By adarroug Date 2005-07-08 Time 11:48 Sent To B
Notes
2005-07-08 00:00:00TO "LSMITH" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-11-08 Cont ID  
Sent By csiegber Date 2004-11-08 Time 11:02 Rev Time 0.00
Received By csiegber Date 2004-11-08 Time 11:02 Sent To P
Notes
2004-11-08 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-10-26 Cont ID  
Sent By mmclean Date 2004-10-13 Time 17:11 Rev Time 0.00
Received By lsmith Date 2004-09-22 Time 14:50 Sent To  
Notes
2004-10-14 00:00:00TO SFD RACK/E
2004-09-22 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-10-15 Cont ID  
Sent By btrobaug Date 2004-10-14 Time 17:24 Rev Time 0.30
Received By pkrauss Date 2004-10-15 Time 06:53 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-11-12 Cont ID  
Sent By kstevens Date 2004-11-12 Time 18:24 Rev Time 0.25
Received By kstevens Date 2004-11-12 Time 18:24 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-10-21 Cont ID  
Sent By pkrauss Date 2004-10-15 Time 07:07 Rev Time 0.75
Received By kstevens Date 2004-10-21 Time 12:53 Sent To B
Notes
2004-10-21 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT A4 SANITARY RISER DIAGRAM DOES
 NOT REFLECT THE FLOOR PLAN, NOR DOES IT
 MEET CODE REQUIREMENTS.
 A) A STANDPIPE IS REQUIRED FOR THE WASH
 MACHINE. SECTION 1002.1 & 802.4 - THE
 CLEANOUT FOR THE WASH MACHINE SHALL BE
 LOCATED 4' ABOVE THE FLOOR FOR ACCESS.
 SECTION 708.10.
 B) THE MASTER BATH SHOWS ONE LAV ON THE
 FLOOR PLAN, BUT SHOWS TWO ON THE SANIT-
 ARY RISER DIAGRAM. CORRELATE RISER WITH
 FLOOR PLAN. SECTION 104.2.1.
 C) THE MASTER BATH FLOOR PLAN SHOWS THE
 BIDET UPSTREAM OF THE WATER CLOSET ON
 THE SAME WALL BUT THE RISER DIAGRAM
 SHOWS THE BIDET BETWEEN THE W/C AND THE
 LAV. SECTION 104.2.1
 D) FLOOR PLAN FOR BATH #2 SHOWS A SHOW-
 ER, BUT THE RISER DIAGRAM SHOWS A TUB.
 PLEASE CORRELATE RISER WITH THE FLOOR
 PLAN. SECTION 104.2.1.
 E) SUMMER KITCHEN SINK SHALL DISCHARGE
 DOWNSTREAM OF THE HORIZONTAL WET VENT
 FOR THE CABANA BATHROOM FIXTURES. SECT-
 ION 909.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-10-13 Cont ID  
Sent By mmclean Date 2004-10-13 Time 17:11 Rev Time 0.00
Received By mmclean Date 2004-10-13 Time 17:11 Sent To I
Notes
***NONE***