| Plan Review Stops For Permit 04090582 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-11-17 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-11-17 |
Time |
15:30 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2004-11-17 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2004-11-17 00:00:00 | RECEIVED CORRECTED PRODUCT APPROVALS FOR | | | THE IMPACT GLASS FIXED WINDOWS.LS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-11-08 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-11-08 |
Time |
09:58 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2004-11-08 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-10-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-21 |
Time |
12:53 |
Rev Time |
4.00 |
| Received By |
lsmith |
Date |
2004-10-26 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2004-10-26 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | 1. THE ENERGY CODE FORM HAS TO BE | | | SIGNED BY THE OWNER/AGENT. | | | | | | 2.THERE ARE NO PRODUCT APPROVALS FOR | | | THE CASEMENT WINDOWS SHOWN ON THE PLANS. | | | | | | 3. THERE ARE PRODUCT APPROVALS FOR | | | THERMA-TRU DOORS THAT REQUIRE STORM | | | PANELS. | | | | | | 4. THE FIXED WINDOWS ARE "SMALL MISSLE | | | IMPACT". WHEN INSTALLED UNDER 30' THEY | | | REQUIRE STORM PANELS.NO STORM PANEL | | | INFORMATION SUBMITTED. | | | | | | 5. ADDITIONAL FEES ARE DUE BEFORE | | | PERMITCAN BE ISSUED INCLUDING APPROACH | | | FEE. | | | | | | 6. NO GLASS BLOCK SHOWN ON PLANS BUT | | | PRODUCT APPROVAL SUBMITTED. REMOVE ALL | | | PRODUCT APPROVALS FOR ITEMS NOT ON PLANS | | | | | | 7. A NOTICE OF COMMENCEMENT MUST BE | | | FILED AT THE COUNTY CLERK OFFICE & | | | SUBMITTED BEFORE A PERMIT CAN BE ISSUED. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-03-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-13 |
Time |
13:24 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-03-13 |
Time |
13:10 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-03-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-06 |
Time |
12:38 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-03-05 |
Time |
14:36 |
Sent To |
PC |
|
| Notes |
| 2007-03-06 12:17:23 | | | | | | | REVISION DENIED | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | THE WIRE SIZE AND OCPDO NOT COMPLY WITH 240 OR | | | 310.16, OR BOTH IN THE FOLLOWING: | | | 1} CIRCUIT 1&3,5&7, AND 9&11 PANEL "A". | | | 2} CIRCUITS 2&4 PANEL"C". | | | | | | ALTHOUGH #6 CONDUCTORS ON A 30 AMP OCP ARE NOT A | | | VIOLATION, THEY WILL NOT PHYSICALLY FIT ON THE BREAKER. | | | AND MUST BE INSTALLED PER PLAN, OR CHANGE THE PLAN TO | | | INDICATE ACTUAL CONDITIONS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-22 |
Time |
12:46 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-12-22 |
Time |
11:54 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-03-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-27 |
Time |
17:13 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-27 |
Time |
16:55 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-11-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-11-17 |
Time |
13:42 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-11-17 |
Time |
13:33 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-10-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-10-14 |
Time |
17:24 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-10-14 |
Time |
16:55 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-02-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-28 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-28 |
Time |
11:48 |
Sent To |
E |
|
| Notes |
| 2007-02-28 11:48:25 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-12-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-17 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-17 |
Time |
13:40 |
Sent To |
E |
|
| Notes |
| 2006-12-17 13:40:53 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-23 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-23 |
Time |
14:08 |
Sent To |
E |
|
| Notes |
| 2006-03-23 00:00:00 | TO BT'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-08 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-08 |
Time |
11:48 |
Sent To |
B |
|
| Notes |
| 2005-07-08 00:00:00 | TO "LSMITH" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-11-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-08 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-08 |
Time |
11:02 |
Sent To |
P |
|
| Notes |
| 2004-11-08 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-10-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-10-13 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-09-22 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2004-10-14 00:00:00 | TO SFD RACK/E | | 2004-09-22 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-10-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-10-14 |
Time |
17:24 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-10-15 |
Time |
06:53 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-12 |
Time |
18:24 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-11-12 |
Time |
18:24 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-10-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-15 |
Time |
07:07 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2004-10-21 |
Time |
12:53 |
Sent To |
B |
|
| Notes |
| 2004-10-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHT A4 SANITARY RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN, NOR DOES IT | | | MEET CODE REQUIREMENTS. | | | A) A STANDPIPE IS REQUIRED FOR THE WASH | | | MACHINE. SECTION 1002.1 & 802.4 - THE | | | CLEANOUT FOR THE WASH MACHINE SHALL BE | | | LOCATED 4' ABOVE THE FLOOR FOR ACCESS. | | | SECTION 708.10. | | | B) THE MASTER BATH SHOWS ONE LAV ON THE | | | FLOOR PLAN, BUT SHOWS TWO ON THE SANIT- | | | ARY RISER DIAGRAM. CORRELATE RISER WITH | | | FLOOR PLAN. SECTION 104.2.1. | | | C) THE MASTER BATH FLOOR PLAN SHOWS THE | | | BIDET UPSTREAM OF THE WATER CLOSET ON | | | THE SAME WALL BUT THE RISER DIAGRAM | | | SHOWS THE BIDET BETWEEN THE W/C AND THE | | | LAV. SECTION 104.2.1 | | | D) FLOOR PLAN FOR BATH #2 SHOWS A SHOW- | | | ER, BUT THE RISER DIAGRAM SHOWS A TUB. | | | PLEASE CORRELATE RISER WITH THE FLOOR | | | PLAN. SECTION 104.2.1. | | | E) SUMMER KITCHEN SINK SHALL DISCHARGE | | | DOWNSTREAM OF THE HORIZONTAL WET VENT | | | FOR THE CABANA BATHROOM FIXTURES. SECT- | | | ION 909.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-10-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-10-13 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-10-13 |
Time |
17:11 |
Sent To |
I |
|
| Notes |
|
|