Plan Review Details - Permit 04090575
Plan Review Stops For Permit 04090575
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-03-31 Cont ID  
Sent By jgomez Date 2005-03-31 Time 13:32 Rev Time 0.50
Received By jgomez Date 2005-03-31 Time 13:32 Sent To PC
Notes
2005-03-31 00:00:00PLANS DELETED THE BBQ IN THE PORCH.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2005-02-11 Cont ID  
Sent By jgomez Date 2005-02-11 Time 16:19 Rev Time 2.00
Received By jgomez Date 2005-02-11 Time 16:19 Sent To Z
Notes
2005-02-11 00:00:00BUILDING REVIEW COMMENTS:
 EXTENSION OF REAR PORCH WAS APPROVED,
 BUT THE FOLLOWING ITEMS NEED TO BE
 REVISED AS REQUIRED:
 1- BBQ SPECS SAY "DO NOT INSTALL A GRILL
 BELOW OVERHEAD UNPROTECTED COMBUSTIBLE
 CONSTRUCTION" AND "DO NOT LOCATE THE
 GRILL IN A BUILDING, GARAGE OR OTHER
 ENCLOSED AREA".PROVIDE MANUFACTURER
 SPECS CLARIFYING THAT BBQ WILL BE OK TO
 INSTALL IN PORCH.
  
 2- REVISE ROOF FRAMING PLAN. TRUSS
 BEARING ELEVATIONS NOTED AT ENTRY PORCH
 ARE INCORRECT.
  
 3- DETAIL M/6 AND ROOF FRAMING PLAN
 DON'T MATCH. REVISE: A) TYPE OF BEAM.
 B) NEED WOOD TO WOOD CONNECTOR. A1
 CONNECTOR DON'T WORK FOR WOOD FRAMED BOX
 C) ROOF FRAMING LAYOUT AND DETAIL DON'T
 MATCH. SEE FRAMING AND OVERFRAMING SHOWN
 ON ROOF PLAN.
 D) SPECIFY FIREBLOCKING ON DETAIL M/6.
 SECTION 2305.1 FBC 2001.
 E) THERE ARE 2 DIFFERENT ATTIC VENTS
 SPECS. CLARIFY WHICH ONE APPLY.
 F) SPECIFY METAL ANCHORS. "APPROVED
 METAL ANCHORS ARE NOT SUFFICIENT INFO.
 SEC. 104.2.1 CITY AMENDMENTS TO FBC 2001

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-01-19 Cont ID  
Sent By jgomez Date 2005-01-19 Time 16:45 Rev Time 0.00
Received By jgomez Date 2005-01-19 Time 16:45 Sent To Z
Notes
2005-01-19 00:00:00CHECKLIST:
  
 1-REVISE ENTRY PORCH ROOF FRAMING PLAN
 AND ALL DETAILS. CHECK BEARING HEIGHTS
 AND FRAMING OF ENTRY PORCH. CLEARLY
 SPECIFY ALL CONNECTORS INCLUDING AT TOP
 AND BOTTOM CONNECTIONS. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 2-CHIMNEY IS SHOWN ONLY ON THE FRONT
 ELEVATION. SHOW CHIMNEY ON ALL
 ELEVATIONS AS REQUIRED. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
  
 3-FIREPLACE: PROVIDE MANUFACTURER'S
 SPECIFICATIONS THAT ALLOWS FLUE CAP TO
 HAVE CEILING ABOVE. SPECIFY ALL
 REQUIRED
 CLEARANCES TO ALLOW PROPER EXHAUST OF
 FUMES. SEC. 104.2.1.2 CITY AMENDMENTS
 TO
 FBC 2001.
  
 4- PROVIDE SPECIFIC LISTING SHOWING
 COMPLIANCE WITH UL 127. SEE SECTIONS
 2806.1.1 AND 2806.1.2 FBC 2001.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-11-24 Cont ID  
Sent By jgomez Date 2004-11-24 Time 15:22 Rev Time 0.00
Received By jleech Date 2004-12-11 Time 11:03 Sent To Z
Notes
2004-11-24 00:00:00BUILDING REVIEW PROVISO:
 1-NOTICE OF COMMENCEMENT DOESN'T HAVE A
 GENERAL DESCRIPTION OF IMPROVEMENT. FILL
 IN INFORMATION AND RE-RECORD AS
 REQUIRED.
  
 2-PROVIDE FLORIDA/LOCAL PRODUCT APPROVAL
 FOR ENTRY DOORS WITH MISSILE IMPACT
 PROTECTION AS REQ'D ON PLANS.
  
 3-PROVIDE DADE COUNTY NOA THAT MATCHES
 INFORMATION SUBMITTED FOR FLORIDA
 PRODUCT APPROVAL FOR FIXED WINDOWS FL.
 NUMBER 243.
  
 4-PROVIDE UL LISTING AND COMPLETE SPECS
 FOR NEW FIREPLACE. SEC. 2806 FBC 2001.
 ***NOTE:
 MAKE SURE THAT SPECS ALLOWS CAP TO BE
 BUILT ABOVE FLUE.
  
 5-SURVEY WAS NOT PROVIDED THIS TIME.
 PLEASE, RESUBMIT IT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-10-26 Cont ID  
Sent By kstevens Date 2004-10-21 Time 18:43 Rev Time 2.50
Received By jgomez Date 2004-10-26 Time 16:12 Sent To PC
Notes
2004-10-26 00:00:00CHECKLIST:
 1-STORM SHUTTERS NOTE ON DWG A1 CALLS
 FOR SHUTTERS ON ALL OPENINGS & IMPACT
 GLAZING FOR ENTRY DOOR. PRODUCT APPRO-
 VALS SUBMITTED ARE FOR IMPACT GLAZING
 ON DOORS/WINDOWS AND ENTRY DOORS NEED
 SHUTTERS. CLARIFY AND REVISE AS REQ'D.
 **NOTE: PROVIDE COMPLETE INFORMATION FOR
 STORM SHUTTERS IF USED.
 2-DRAWING A3: A)ROOF LOADS CHART & NOTE
 ABOVE ROOF FRAMING PLAN LETTERING ARE
 CONTRADICTING EACH OTHER. REVISE AS
 REQUIRED & SPECIFY 30PSF OR 10PSF LIVE
 LOAD AS REQUIRED BY TABLE 1604.1 FBC.
 B)ROOF SHEATHING NOTE: ZONE 3 ISN'T ONLY
 AT ALL 4 CORNERS OF ROOF. ZONE 3 ARE
 ALL CORNERS THROUGHOUT ENTIRE ROOF.
 REVISE AS REQUIRED. SEC. 104.2.1.2 OF
 CITY AMENDMENTS TO FBC 2001.
 C)KEY DETAILS SO THEY MATCH DETAILS ON
 DRAWING A6. REVISE AS REQUIRED.
 3-OWNER/AGENT TO SIGN AND DATE THE
 ENERGY CALCULATIONS (BOTH COPIES).
 4-PROVIDE BBQ UL LISTING AND SPECS.
 SEC. 2808 FBC 2001.
 5-PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR: A)FIXED WINDOWS FOR
 LARGE MISSILE IMPACT, NOT FOR SMALL
 MISSILE IMPACT. SEC. 1606.1.4 FBC 2001
 B)ENTRY DOOR WITH MISSILE IMPACT GLAZING
 AS SPECIFIED ON PLANS.
 6-PROVIDE COMPLETE DETAIL THAT SHOWS HOW
 ARE ENTRY PORCH TRUSS GIRDERS ATTACHED
 TO MASONRY WALL. DETAIL C/6 DO NOT
 MATCH SUCH CONDITION. REVISE DETAIL.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 7-PROVIDE COMPLETE FRAMING SECTION
 DETAIL AT ENTRY PORCH TO CLARIFY HOW
 IS PORCH SPECIFIED TO BE BUILT. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 8-MULLION PRODUCT APPROVAL: CLEARLY
 MARK ALL COMPONENTS TO BE USED ON THIS
 PROJECT ACCORDING TO THE SPAN AND SIZE
 OF MULLIONS. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 9-DETAIL G/6: SPECIFY ALL FASTENERS.
 HOW ARE 2X4'S FASTENED, ETC. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001`
 10-SHEET A7: CROSS SECTIONS DWGS FOR THE
 BEAMS AND LINTELS NEED THE ENGINEER'S
 ORIGINAL SIGNATURE, DATE AND SEAL AS
 REQUIRED BY CHAPTER 471 FL STATUTES.
 **ALSO, DRAWINGS ARE NOT LEGIBLE.
 11-OWES $2138.98 FOR UPDATED VALUE AND
 UNPAID BALANCE AT TIME OF APPLICATION.
 12-PLEASE, PROVIDE ONLY THE DETAILS THAT
 APPLY TO THIS PROJECT TO EXPEDITE THE
 REVIEW PROCESS AND AVOID CONFLICTS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2005-08-12 Cont ID  
Sent By btrobaug Date 2005-08-12 Time 07:34 Rev Time 0.50
Received By btrobaug Date 2005-08-12 Time 07:30 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-01-06 Cont ID  
Sent By btrobaug Date 2005-01-06 Time 15:28 Rev Time 0.50
Received By btrobaug Date 2005-01-06 Time 14:47 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-12-17 Cont ID  
Sent By btrobaug Date 2004-12-17 Time 11:35 Rev Time 0.50
Received By btrobaug Date 2004-12-17 Time 10:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-11-16 Cont ID  
Sent By btrobaug Date 2004-11-16 Time 13:56 Rev Time 0.50
Received By btrobaug Date 2004-11-16 Time 13:28 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-10-14 Cont ID  
Sent By btrobaug Date 2004-10-14 Time 14:30 Rev Time 0.50
Received By btrobaug Date 2004-10-14 Time 12:35 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2005-11-08 Cont ID  
Sent By adarroug Date 2005-11-08 Time 08:48 Rev Time 0.00
Received By adarroug Date 2005-11-08 Time 08:48 Sent To P
Notes
2005-11-08 00:00:00TO "P" BOX

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-08-08 Cont ID  
Sent By adarroug Date 2005-08-08 Time 10:59 Rev Time 0.00
Received By adarroug Date 2005-08-08 Time 10:59 Sent To E
Notes
2005-08-08 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-03-10 Cont ID  
Sent By adarroug Date 2005-03-10 Time 11:11 Rev Time 0.00
Received By adarroug Date 2005-03-10 Time 11:11 Sent To B
Notes
2005-03-10 00:00:00TO "JGOMEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-02-07 Cont ID  
Sent By adarroug Date 2005-02-07 Time 09:27 Rev Time 0.00
Received By adarroug Date 2005-02-07 Time 09:27 Sent To I
Notes
2005-02-07 00:00:00TO "M" BOX

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-01-05 Cont ID  
Sent By mjacobs Date 2005-01-05 Time 16:40 Rev Time 0.00
Received By mjacobs Date 2005-01-05 Time 16:40 Sent To E
Notes
2005-01-05 00:00:00TO "BT" DESK/REVISION.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-12-16 Cont ID  
Sent By mjacobs Date 2004-12-16 Time 10:35 Rev Time 0.00
Received By mjacobs Date 2004-12-16 Time 10:35 Sent To E
Notes
2004-12-16 00:00:00SENT TO "BT" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-12-06 Cont ID  
Sent By mjacobs Date 2004-12-06 Time 12:02 Rev Time 0.00
Received By mjacobs Date 2004-12-06 Time 12:02 Sent To P
Notes
2004-12-06 00:00:00SENT TO "P" BOX./RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-11-08 Cont ID  
Sent By csiegber Date 2004-11-08 Time 11:55 Rev Time 0.00
Received By csiegber Date 2004-11-08 Time 11:55 Sent To P
Notes
2004-11-08 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-10-26 Cont ID  
Sent By mmclean Date 2004-10-13 Time 17:11 Rev Time 0.00
Received By jgomez Date 2004-09-22 Time 14:50 Sent To PC
Notes
2004-10-14 00:00:00TO SFD RACK/E
2004-09-22 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 4 Status N Date 2005-02-08 Cont ID  
Sent By pkrauss Date 2005-02-08 Time 07:39 Rev Time 0.40
Received By pkrauss Date 2005-02-08 Time 07:20 Sent To B
Notes
2005-02-08 00:00:00PLEASE NOTE, SUBMITTAL FOR THE GAS FIRED
 FIRE PLACE.PLEASE INDICATE WHICH MODEL
 WILL BE INSTALLED

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2005-01-14 Cont ID  
Sent By prafter Date 2005-01-14 Time 10:00 Rev Time 2.00
Received By prafter Date 2005-01-14 Time 09:59 Sent To B
Notes
2005-01-14 00:00:00MECH. REV. ON 42" WOOD BURNING
 FIREPLACE.
 1. CHIMNEY DETAIL ON PLAN SHOWS
 TURMINING IN SEM-INCLOSED AREA.
 REQUSTING MANFACTURE TERMINATION
 INFORMATION ON THIS APPLATION.
 2. WILL THIS FIREPLACE HAVE COMBUSTION
 AIR AND IF SO PROVIDE DETAIL
 INFORMATION.
 3. WHAT MODEL 42" WOOD BURNING
 FIREPLACE GOING TO BE PURCHASED.
 PAT RAFTER 561/805/6725 OR 805/6719.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-11-23 Cont ID  
Sent By prafter Date 2004-11-23 Time 08:35 Rev Time 0.45
Received By prafter Date 2004-11-23 Time 08:34 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-10-15 Cont ID  
Sent By btrobaug Date 2004-10-14 Time 14:30 Rev Time 0.30
Received By pkrauss Date 2004-10-15 Time 06:41 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status P Date 2005-11-28 Cont ID  
Sent By kstevens Date 2005-11-28 Time 11:30 Rev Time 0.50
Received By kstevens Date 2005-11-28 Time 11:30 Sent To  
Notes
2005-11-28 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 4 Status P Date 2005-01-12 Cont ID  
Sent By jleech Date 2005-01-12 Time 10:58 Rev Time 0.50
Received By jleech Date 2005-01-12 Time 10:57 Sent To M
Notes
2005-01-12 00:00:00RESTAMP OK ELECTRICAL PLAN CHANGED

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-12-11 Cont ID  
Sent By jleech Date 2004-12-11 Time 11:05 Rev Time 0.33
Received By jleech Date 2004-12-11 Time 11:05 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-11-12 Cont ID  
Sent By kstevens Date 2004-11-12 Time 18:42 Rev Time 0.33
Received By kstevens Date 2004-11-12 Time 18:42 Sent To E
Notes
2004-11-12 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
  
  
 1) SHT 4 SANITARY RISER DIAGRAM DOES NOT
 REFLECT THE FLOOR PLAN FOR BATHROOM #4.
 THE RISER NOW SHOWS A TUB ON THE LEFT
 SIDE OF THE BATHROOM, WHERE THERE IS A
 SHOWER ON THE RIGHT SIDE OF THE
 BATHROOM. SEE ORIGINAL RISER DIAGRAM.
 CHANGES WERE MADE NOT REQUESTED ON FIRST
 REVIEW. PLEASE CLARIFY. SECTION
 104.2.1.
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-10-21 Cont ID  
Sent By pkrauss Date 2004-10-15 Time 06:52 Rev Time 0.00
Received By jgomez Date 2005-02-11 Time 16:17 Sent To B
Notes
2004-10-21 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT A4 0F 7 SANITARY RISER DIAGRAM
 DOES NOT REFLECT THE FLOOR PLAN.
 A) CABANA BATH SHOWS A SHOWER ON THE
 RISER DIAGRAM THAT IS NOT ON THE FLOOR
 PLAN. SECTION 104.2.1
 B) MASTER BATH SHOWS THE BIDET TO THE
 RIGHT OF THE W/C ON THE FLOOR PLAN, NOT
 BETWEEN THE W/C AND THE LAV AS SHOWN ON
 THE RISER DIAGRAM. SECTION 104.2.1
 C) THE WASH MACHINE REQUIRES A STAND-
 PIPE. SECTION 1002.1 & 802.4. - ALSO THE
 WASH MACHINE CLEANOUT SHALL BE 4' ABOVE
 THE FLOOR FOR ACCESS. SECTION 708.10.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2005-01-24 Cont ID  
Sent By mmclean Date 2005-01-24 Time 16:31 Rev Time 0.00
Received By mmclean Date 2005-01-24 Time 16:31 Sent To  
Notes
2005-01-24 00:00:00NEED TO PROVIDE ANOTHER COPY OF SURVEY
 FOR APPROVAL.CALLED CONTR FOR P/U FILE
 D MM

Review Stop Z ZONING
Rev No 2 Status P Date 2004-12-03 Cont ID  
Sent By mmclean Date 2004-12-03 Time 09:03 Rev Time 0.00
Received By mmclean Date 2004-12-03 Time 09:03 Sent To I
Notes
2004-12-03 00:00:00NEW SURVEY APPROVED. MUST PULL A
 SEPARATE FOR POOL/SPA/DECK/SCREEN
 ENCLOSURE.

Review Stop Z ZONING
Rev No 1 Status P Date 2004-10-13 Cont ID  
Sent By mmclean Date 2004-10-13 Time 17:11 Rev Time 0.00
Received By mmclean Date 2004-10-13 Time 17:11 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved