| Plan Review Stops For Permit 04090575 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-03-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-03-31 |
Time |
13:32 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2005-03-31 |
Time |
13:32 |
Sent To |
PC |
|
| Notes |
| 2005-03-31 00:00:00 | PLANS DELETED THE BBQ IN THE PORCH. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2005-02-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-02-11 |
Time |
16:19 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-02-11 |
Time |
16:19 |
Sent To |
Z |
|
| Notes |
| 2005-02-11 00:00:00 | BUILDING REVIEW COMMENTS: | | | EXTENSION OF REAR PORCH WAS APPROVED, | | | BUT THE FOLLOWING ITEMS NEED TO BE | | | REVISED AS REQUIRED: | | | 1- BBQ SPECS SAY "DO NOT INSTALL A GRILL | | | BELOW OVERHEAD UNPROTECTED COMBUSTIBLE | | | CONSTRUCTION" AND "DO NOT LOCATE THE | | | GRILL IN A BUILDING, GARAGE OR OTHER | | | ENCLOSED AREA".PROVIDE MANUFACTURER | | | SPECS CLARIFYING THAT BBQ WILL BE OK TO | | | INSTALL IN PORCH. | | | | | | 2- REVISE ROOF FRAMING PLAN. TRUSS | | | BEARING ELEVATIONS NOTED AT ENTRY PORCH | | | ARE INCORRECT. | | | | | | 3- DETAIL M/6 AND ROOF FRAMING PLAN | | | DON'T MATCH. REVISE: A) TYPE OF BEAM. | | | B) NEED WOOD TO WOOD CONNECTOR. A1 | | | CONNECTOR DON'T WORK FOR WOOD FRAMED BOX | | | C) ROOF FRAMING LAYOUT AND DETAIL DON'T | | | MATCH. SEE FRAMING AND OVERFRAMING SHOWN | | | ON ROOF PLAN. | | | D) SPECIFY FIREBLOCKING ON DETAIL M/6. | | | SECTION 2305.1 FBC 2001. | | | E) THERE ARE 2 DIFFERENT ATTIC VENTS | | | SPECS. CLARIFY WHICH ONE APPLY. | | | F) SPECIFY METAL ANCHORS. "APPROVED | | | METAL ANCHORS ARE NOT SUFFICIENT INFO. | | | SEC. 104.2.1 CITY AMENDMENTS TO FBC 2001 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-01-19 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2005-01-19 |
Time |
16:45 |
Sent To |
Z |
|
| Notes |
| 2005-01-19 00:00:00 | CHECKLIST: | | | | | | 1-REVISE ENTRY PORCH ROOF FRAMING PLAN | | | AND ALL DETAILS. CHECK BEARING HEIGHTS | | | AND FRAMING OF ENTRY PORCH. CLEARLY | | | SPECIFY ALL CONNECTORS INCLUDING AT TOP | | | AND BOTTOM CONNECTIONS. SECTION | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | 2-CHIMNEY IS SHOWN ONLY ON THE FRONT | | | ELEVATION. SHOW CHIMNEY ON ALL | | | ELEVATIONS AS REQUIRED. SEC. 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | | | | 3-FIREPLACE: PROVIDE MANUFACTURER'S | | | SPECIFICATIONS THAT ALLOWS FLUE CAP TO | | | HAVE CEILING ABOVE. SPECIFY ALL | | | REQUIRED | | | CLEARANCES TO ALLOW PROPER EXHAUST OF | | | FUMES. SEC. 104.2.1.2 CITY AMENDMENTS | | | TO | | | FBC 2001. | | | | | | 4- PROVIDE SPECIFIC LISTING SHOWING | | | COMPLIANCE WITH UL 127. SEE SECTIONS | | | 2806.1.1 AND 2806.1.2 FBC 2001. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-11-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-11-24 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2004-12-11 |
Time |
11:03 |
Sent To |
Z |
|
| Notes |
| 2004-11-24 00:00:00 | BUILDING REVIEW PROVISO: | | | 1-NOTICE OF COMMENCEMENT DOESN'T HAVE A | | | GENERAL DESCRIPTION OF IMPROVEMENT. FILL | | | IN INFORMATION AND RE-RECORD AS | | | REQUIRED. | | | | | | 2-PROVIDE FLORIDA/LOCAL PRODUCT APPROVAL | | | FOR ENTRY DOORS WITH MISSILE IMPACT | | | PROTECTION AS REQ'D ON PLANS. | | | | | | 3-PROVIDE DADE COUNTY NOA THAT MATCHES | | | INFORMATION SUBMITTED FOR FLORIDA | | | PRODUCT APPROVAL FOR FIXED WINDOWS FL. | | | NUMBER 243. | | | | | | 4-PROVIDE UL LISTING AND COMPLETE SPECS | | | FOR NEW FIREPLACE. SEC. 2806 FBC 2001. | | | ***NOTE: | | | MAKE SURE THAT SPECS ALLOWS CAP TO BE | | | BUILT ABOVE FLUE. | | | | | | 5-SURVEY WAS NOT PROVIDED THIS TIME. | | | PLEASE, RESUBMIT IT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-10-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-21 |
Time |
18:43 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2004-10-26 |
Time |
16:12 |
Sent To |
PC |
|
| Notes |
| 2004-10-26 00:00:00 | CHECKLIST: | | | 1-STORM SHUTTERS NOTE ON DWG A1 CALLS | | | FOR SHUTTERS ON ALL OPENINGS & IMPACT | | | GLAZING FOR ENTRY DOOR. PRODUCT APPRO- | | | VALS SUBMITTED ARE FOR IMPACT GLAZING | | | ON DOORS/WINDOWS AND ENTRY DOORS NEED | | | SHUTTERS. CLARIFY AND REVISE AS REQ'D. | | | **NOTE: PROVIDE COMPLETE INFORMATION FOR | | | STORM SHUTTERS IF USED. | | | 2-DRAWING A3: A)ROOF LOADS CHART & NOTE | | | ABOVE ROOF FRAMING PLAN LETTERING ARE | | | CONTRADICTING EACH OTHER. REVISE AS | | | REQUIRED & SPECIFY 30PSF OR 10PSF LIVE | | | LOAD AS REQUIRED BY TABLE 1604.1 FBC. | | | B)ROOF SHEATHING NOTE: ZONE 3 ISN'T ONLY | | | AT ALL 4 CORNERS OF ROOF. ZONE 3 ARE | | | ALL CORNERS THROUGHOUT ENTIRE ROOF. | | | REVISE AS REQUIRED. SEC. 104.2.1.2 OF | | | CITY AMENDMENTS TO FBC 2001. | | | C)KEY DETAILS SO THEY MATCH DETAILS ON | | | DRAWING A6. REVISE AS REQUIRED. | | | 3-OWNER/AGENT TO SIGN AND DATE THE | | | ENERGY CALCULATIONS (BOTH COPIES). | | | 4-PROVIDE BBQ UL LISTING AND SPECS. | | | SEC. 2808 FBC 2001. | | | 5-PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: A)FIXED WINDOWS FOR | | | LARGE MISSILE IMPACT, NOT FOR SMALL | | | MISSILE IMPACT. SEC. 1606.1.4 FBC 2001 | | | B)ENTRY DOOR WITH MISSILE IMPACT GLAZING | | | AS SPECIFIED ON PLANS. | | | 6-PROVIDE COMPLETE DETAIL THAT SHOWS HOW | | | ARE ENTRY PORCH TRUSS GIRDERS ATTACHED | | | TO MASONRY WALL. DETAIL C/6 DO NOT | | | MATCH SUCH CONDITION. REVISE DETAIL. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | 7-PROVIDE COMPLETE FRAMING SECTION | | | DETAIL AT ENTRY PORCH TO CLARIFY HOW | | | IS PORCH SPECIFIED TO BE BUILT. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | 8-MULLION PRODUCT APPROVAL: CLEARLY | | | MARK ALL COMPONENTS TO BE USED ON THIS | | | PROJECT ACCORDING TO THE SPAN AND SIZE | | | OF MULLIONS. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | 9-DETAIL G/6: SPECIFY ALL FASTENERS. | | | HOW ARE 2X4'S FASTENED, ETC. SECTION | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001` | | | 10-SHEET A7: CROSS SECTIONS DWGS FOR THE | | | BEAMS AND LINTELS NEED THE ENGINEER'S | | | ORIGINAL SIGNATURE, DATE AND SEAL AS | | | REQUIRED BY CHAPTER 471 FL STATUTES. | | | **ALSO, DRAWINGS ARE NOT LEGIBLE. | | | 11-OWES $2138.98 FOR UPDATED VALUE AND | | | UNPAID BALANCE AT TIME OF APPLICATION. | | | 12-PLEASE, PROVIDE ONLY THE DETAILS THAT | | | APPLY TO THIS PROJECT TO EXPEDITE THE | | | REVIEW PROCESS AND AVOID CONFLICTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-08-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-12 |
Time |
07:34 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-12 |
Time |
07:30 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-06 |
Time |
15:28 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-06 |
Time |
14:47 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-12-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-12-17 |
Time |
11:35 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-12-17 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-11-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-11-16 |
Time |
13:56 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-11-16 |
Time |
13:28 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-10-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-10-14 |
Time |
14:30 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-10-14 |
Time |
12:35 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-11-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-08 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-08 |
Time |
08:48 |
Sent To |
P |
|
| Notes |
| 2005-11-08 00:00:00 | TO "P" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-08-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-08 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-08 |
Time |
10:59 |
Sent To |
E |
|
| Notes |
| 2005-08-08 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-10 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-10 |
Time |
11:11 |
Sent To |
B |
|
| Notes |
| 2005-03-10 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-02-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-07 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-07 |
Time |
09:27 |
Sent To |
I |
|
| Notes |
| 2005-02-07 00:00:00 | TO "M" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-05 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-05 |
Time |
16:40 |
Sent To |
E |
|
| Notes |
| 2005-01-05 00:00:00 | TO "BT" DESK/REVISION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-12-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-16 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-16 |
Time |
10:35 |
Sent To |
E |
|
| Notes |
| 2004-12-16 00:00:00 | SENT TO "BT" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-12-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-06 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-06 |
Time |
12:02 |
Sent To |
P |
|
| Notes |
| 2004-12-06 00:00:00 | SENT TO "P" BOX./RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-11-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-08 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-08 |
Time |
11:55 |
Sent To |
P |
|
| Notes |
| 2004-11-08 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-10-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-10-13 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-09-22 |
Time |
14:50 |
Sent To |
PC |
|
| Notes |
| 2004-10-14 00:00:00 | TO SFD RACK/E | | 2004-09-22 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
N |
Date |
2005-02-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-02-08 |
Time |
07:39 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-02-08 |
Time |
07:20 |
Sent To |
B |
|
| Notes |
| 2005-02-08 00:00:00 | PLEASE NOTE, SUBMITTAL FOR THE GAS FIRED | | | FIRE PLACE.PLEASE INDICATE WHICH MODEL | | | WILL BE INSTALLED |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-14 |
Time |
10:00 |
Rev Time |
2.00 |
| Received By |
prafter |
Date |
2005-01-14 |
Time |
09:59 |
Sent To |
B |
|
| Notes |
| 2005-01-14 00:00:00 | MECH. REV. ON 42" WOOD BURNING | | | FIREPLACE. | | | 1. CHIMNEY DETAIL ON PLAN SHOWS | | | TURMINING IN SEM-INCLOSED AREA. | | | REQUSTING MANFACTURE TERMINATION | | | INFORMATION ON THIS APPLATION. | | | 2. WILL THIS FIREPLACE HAVE COMBUSTION | | | AIR AND IF SO PROVIDE DETAIL | | | INFORMATION. | | | 3. WHAT MODEL 42" WOOD BURNING | | | FIREPLACE GOING TO BE PURCHASED. | | | PAT RAFTER 561/805/6725 OR 805/6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2004-11-23 |
Time |
08:35 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2004-11-23 |
Time |
08:34 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-10-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-10-14 |
Time |
14:30 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-10-15 |
Time |
06:41 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2005-11-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-11-28 |
Time |
11:30 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-11-28 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2005-11-28 00:00:00 | REVISION OK - SANT. RISER DIAGRAM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-01-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-12 |
Time |
10:58 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-01-12 |
Time |
10:57 |
Sent To |
M |
|
| Notes |
| 2005-01-12 00:00:00 | RESTAMP OK ELECTRICAL PLAN CHANGED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-12-11 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-12-11 |
Time |
11:05 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-12-11 |
Time |
11:05 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-12 |
Time |
18:42 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-11-12 |
Time |
18:42 |
Sent To |
E |
|
| Notes |
| 2004-11-12 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | | | | 1) SHT 4 SANITARY RISER DIAGRAM DOES NOT | | | REFLECT THE FLOOR PLAN FOR BATHROOM #4. | | | THE RISER NOW SHOWS A TUB ON THE LEFT | | | SIDE OF THE BATHROOM, WHERE THERE IS A | | | SHOWER ON THE RIGHT SIDE OF THE | | | BATHROOM. SEE ORIGINAL RISER DIAGRAM. | | | CHANGES WERE MADE NOT REQUESTED ON FIRST | | | REVIEW. PLEASE CLARIFY. SECTION | | | 104.2.1. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-10-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-15 |
Time |
06:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2005-02-11 |
Time |
16:17 |
Sent To |
B |
|
| Notes |
| 2004-10-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHT A4 0F 7 SANITARY RISER DIAGRAM | | | DOES NOT REFLECT THE FLOOR PLAN. | | | A) CABANA BATH SHOWS A SHOWER ON THE | | | RISER DIAGRAM THAT IS NOT ON THE FLOOR | | | PLAN. SECTION 104.2.1 | | | B) MASTER BATH SHOWS THE BIDET TO THE | | | RIGHT OF THE W/C ON THE FLOOR PLAN, NOT | | | BETWEEN THE W/C AND THE LAV AS SHOWN ON | | | THE RISER DIAGRAM. SECTION 104.2.1 | | | C) THE WASH MACHINE REQUIRES A STAND- | | | PIPE. SECTION 1002.1 & 802.4. - ALSO THE | | | WASH MACHINE CLEANOUT SHALL BE 4' ABOVE | | | THE FLOOR FOR ACCESS. SECTION 708.10. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-24 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-24 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2005-01-24 00:00:00 | NEED TO PROVIDE ANOTHER COPY OF SURVEY | | | FOR APPROVAL.CALLED CONTR FOR P/U FILE | | | D MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-12-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-12-03 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-12-03 |
Time |
09:03 |
Sent To |
I |
|
| Notes |
| 2004-12-03 00:00:00 | NEW SURVEY APPROVED. MUST PULL A | | | SEPARATE FOR POOL/SPA/DECK/SCREEN | | | ENCLOSURE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-10-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-10-13 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-10-13 |
Time |
17:11 |
Sent To |
I |
|
| Notes |
|
|