Plan Review Details - Permit 04090386
Plan Review Stops For Permit 04090386
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-09-21 Cont ID  
Sent By jwitmer Date 2005-09-21 Time 18:07 Rev Time 0.22
Received By jwitmer Date 2005-09-21 Time 18:07 Sent To PC
Notes
2005-09-21 00:00:00BLDG# 25 DENSITY REPORT, SOIL TERMITE
 TREATMENT, TIE IN SURVEY

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-03-15 Cont ID  
Sent By jwitmer Date 2005-03-15 Time 14:49 Rev Time 2.22
Received By jwitmer Date 2005-03-10 Time 14:49 Sent To PC
Notes
2005-03-10 00:00:00PERMIT 04090386
 BLDG # 25
 4640 PORTOFINO WAY
  
 03-09-05 BUILDING PLANS ARE CODE
 COMPLIANT/ REQUIRES IMPACT FEES/ &
 REMAINDER OF PERMIT PAYMENT BEFORE
 ISSUANCE.
  
 BUILDING PROVISO:
 1)TRUSS DRAWINGS TO BE REVIEWED BY THE
 DESIGN PROFESSIONAL.
  
 2)TRUSS DRAWINGS TO BE RESUBMITTED
 BEFORE THE TRUSS ANCHOR AND TRUSS
 FRAMING INSPECTION WITH CORRECTIONS.
 .TRUSS ENGINEERING - IF THEY USE
 "FBC2001/ANSI95" FOR THE CODE, ALONG
 WITH THE PLATES INCREASE OF 1.33, IT
 USES A STRESS INCREASE FOR STEEL WHICH
 IS NOT PERMISSIBLE.THIS IS PER MITEK,
 THE SOFTWARE COMPANY.THE CORRECT CODE
 REFERENCE IS "FBC2001/TPI2002", WHICH
 DOES NOT TAKE A STRESS INCREASE FOR
 STEEL EVEN IF A 1.33 PLATE INCREASE IS
 USED.
  
 3) TRUSS SHOP DRAWING TO BE ORIGINAL
 SIGNATURES AND SEAL OR HAVE A SIGNED &
 SEALED INDEX PAGE LISTING ALL DRAWINGS.
 SEE 61G15-23.002(2)
  
  
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-10-27 Cont ID  
Sent By jwitmer Date 2004-10-27 Time 10:14 Rev Time 2.22
Received By jwitmer Date 2004-10-27 Time 10:14 Sent To  
Notes
2004-10-27 00:00:00SEE PERMIT 04090363 TYPE II BUILDING
 FOR A COMPLETE LIST OF BUILDING COMMENTS
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-03-07 Cont ID  
Sent By dpalmer Date 2005-03-07 Time 18:08 Rev Time 0.25
Received By dpalmer Date 2005-03-07 Time 18:08 Sent To  
Notes
2005-03-07 00:00:00BLDG TYPE II
  
 ELECTRICAL SHEETS STAMPED FOR ALL THREE
 SETS.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2005-02-15 Cont ID  
Sent By dpalmer Date 2005-02-15 Time 06:05 Rev Time 0.00
Received By dpalmer Date 2005-02-15 Time 06:05 Sent To  
Notes
2005-02-15 00:00:00******* UNSAT *****
  
  
 1)NOTE: PLEASE SEE OCP FOR SOME A/C
 UNITS HAVE NOT BEEN CHANGED.
  
 3)NOTE: PLEASE SEE MIN ALUM TO BE #2, #3
 SHOWN ON FEEDERS.
  
 4)NOTE: PLEASE SEE AS-1 STILL REFERENCES
 WRONG ELECTRICAL CODE.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-12-30 Cont ID  
Sent By dpalmer Date 2004-12-30 Time 09:11 Rev Time 1.00
Received By dpalmer Date 2004-12-30 Time 09:11 Sent To  
Notes
2004-12-30 00:00:00SEE REVIEW UNDER 04090363

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-10-07 Cont ID  
Sent By dpalmer Date 2004-10-07 Time 15:03 Rev Time 0.50
Received By dpalmer Date 2004-10-07 Time 15:03 Sent To  
Notes
2004-10-07 00:00:00** PLEASE SEE NOTES UNDER # 04090363

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2004-09-30 Cont ID  
Sent By mamini Date 2004-09-30 Time 14:51 Rev Time 1.00
Received By mamini Date 2004-09-30 Time 14:51 Sent To  
Notes
2004-12-06 00:00:00PASSED:
  
 1. SEE PERMIT# 04120218 FOR
 UNDERGROUND UTILITIES AND SITE WORK,
 PHASE II.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2005-03-01 Cont ID  
Sent By nmccray Date 2005-03-01 Time 15:52 Rev Time 0.00
Received By nmccray Date 2005-03-01 Time 15:52 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-12-07 Cont ID  
Sent By nmccray Date 2004-12-07 Time 10:37 Rev Time 0.00
Received By nmccray Date 2004-12-07 Time 10:37 Sent To  
Notes
2004-12-07 00:00:00SEE NOTES ON PERMIT 04090363

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-03 Cont ID  
Sent By mjacobs Date 2004-12-27 Time 08:04 Rev Time 0.00
Received By mjacobs Date 2004-12-27 Time 08:04 Sent To  
Notes
2005-01-03 00:00:00TO "COMM BD#60

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-03-15 Cont ID  
Sent By jwitmer Date 2004-10-27 Time 11:28 Rev Time 0.00
Received By jwitmer Date 2004-09-22 Time 16:36 Sent To  
Notes
2004-09-22 00:00:00TO COMM BD#55/4 ROLLS & 1 BOX ON RACK

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2006-02-27 Cont ID  
Sent By hmoser Date 2006-02-27 Time 17:22 Rev Time 0.00
Received By hmoser Date 2006-02-27 Time 17:22 Sent To  
Notes
2006-02-27 00:00:00EQUIPMENT CHANGE LETTER WITH PERMIT #
 04090336

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-03-15 Cont ID  
Sent By jwitmer Date 2005-03-15 Time 11:26 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2005-03-15 00:00:00MASTER 04090363 TYPE II

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2005-01-10 Cont ID  
Sent By pkrauss Date 2005-01-10 Time 11:40 Rev Time 0.30
Received By pkrauss Date 2005-01-10 Time 11:40 Sent To  
Notes
2005-01-10 00:00:00DENIED:TYPE II / BUILDING #25
 COMMENT #1 & 3 FROM REVIEW DATED
 10-22-04 WERE NOT ADDRESSED.SEE
 ATTACHED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-10-22 Cont ID  
Sent By pkrauss Date 2004-10-22 Time 07:29 Rev Time 0.30
Received By pkrauss Date 2004-10-22 Time 07:29 Sent To  
Notes
2004-10-22 00:00:00DENIED:TYPE II BUILDING #25
 1.PER 2001 FBC(M) 601.4 EXCEPTION #2
 & 3, RETURN TRANSFER GRILLES SHALL BE
 SIZED AS FOLLOWS:
 RETURN TRANSFER - 50 SQ INCHES OF FREE
 AREA TO 100 CFM OF SUPPLY AIR TO THAT
 AREA.ALL SUPPLY AIR INTO THE MASTER
 SUITE SHALL BE INCLUDED FOR PROPER
 SIZING.
 THE FOLLOWING UNITS ARE NOT SIZED
 PROPERLY - A-1 (DWG AC-U1), A-1LS (DWG
 AC-U4), B-2 (AC-5).
  
 2.PLEASE NOTE, THE TOILET EXHAUST
 TERMINATION SHALL BE SCREENDED IN
 ACCORDANCE WITH 2001 FBC(M) 401.6.
 (DRYER EXHAUST NON-SCREENED)
  
 3.PLAN SHEET PD-1 CONDENSATE RISER,
 CONDENSATE SHALL TERMINATE A MINIMUM OF
 12" AWAY FROM THE BUILDING STRUCTURE PER
 2001 FBC 1503.4.4.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-02-15 Cont ID  
Sent By kstevens Date 2005-02-15 Time 06:54 Rev Time 0.25
Received By kstevens Date 2005-02-15 Time 06:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-10-19 Cont ID  
Sent By kstevens Date 2004-10-19 Time 07:30 Rev Time 0.25
Received By kstevens Date 2004-10-19 Time 07:30 Sent To  
Notes
2004-10-19 00:00:00DENIED
  
 SEE COMMENTS ON PERMIT #04090363
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2005-03-15 Cont ID  
Sent By jwitmer Date 2005-03-15 Time 11:31 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2005-03-15 00:00:00ZONING STAMPED PLAN 01/14/05M MCLEAN