Plan Review Details - Permit 04090232
Plan Review Stops For Permit 04090232
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-10-19 Cont ID  
Sent By jwitmer Date 2004-10-19 Time 12:28 Rev Time 0.55
Received By jwitmer Date 2004-10-19 Time 12:27 Sent To  
Notes
2004-10-19 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04090232
 ADD: 1515 N FLAGLER DR# 100
 CONT: POINTE SITE DEVELOPMENT
 TEL: (561)709-1926
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: PROVISO
  
 704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-01-31 Cont ID  
Sent By dpalmer Date 2005-01-31 Time 13:18 Rev Time 0.30
Received By dpalmer Date 2005-01-31 Time 13:18 Sent To  
Notes
2005-01-31 00:00:00REDLINED PANEL "C" MISSING ON PLANS AS
 SHOWN ON RISER.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-09-22 Cont ID  
Sent By dpalmer Date 2004-09-22 Time 07:21 Rev Time 0.25
Received By dpalmer Date 2004-09-22 Time 07:11 Sent To  
Notes
2004-09-22 00:00:00*** NOTE REDLINED ***
  
 EM/EXT LTS SHOWN AS NEW ARE TO BE
 CIRCUITED PER 700.12E.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2004-10-13 Cont ID  
Sent By mcarsill Date 2004-10-13 Time 17:09 Rev Time 0.00
Received By mcarsill Date 2004-10-13 Time 17:09 Sent To  
Notes
2004-10-13 00:00:001) SEPARATE PLANS AND PERMITS REQUIRED
 FOR FIRE SPRINKLER REMODEL.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-26 Cont ID  
Sent By mjacobs Date 2005-01-26 Time 10:15 Rev Time 0.00
Received By mjacobs Date 2005-01-26 Time 10:15 Sent To E
Notes
2005-01-26 00:00:00TO "DP" DESK/REV.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-10-19 Cont ID  
Sent By jwitmer Date 2004-10-19 Time 13:07 Rev Time 0.00
Received By jwitmer Date 2004-09-15 Time 15:20 Sent To PC
Notes
2004-09-15 00:00:00TO COMM BD#35

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-10-08 Cont ID  
Sent By pkrauss Date 2004-10-08 Time 11:26 Rev Time 0.40
Received By pkrauss Date 2004-10-08 Time 11:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2004-10-19 Cont ID  
Sent By jwitmer Date 2004-10-19 Time 13:07 Rev Time 0.00
Received By jwitmer Date 2004-10-19 Time 13:07 Sent To  
Notes
***NONE***